首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The clinical, electrocardiographic, radiographic, and two-dimensional, M-mode and Doppler echocardiographic findings of five cases of canine ostium secundum type atrial septal defect (ASD) are described. The atrial septal anomaly was associated with other congenital cardiac abnormalities in two dogs: ventricular septal defect in one case and tricuspid dysplasia in the other. ASD was found in addition to dilated cardiomyopathy and suspected atrial thrombosis in one geriatric dog, but was the only cardiac abnormality detected in the remaining two dogs. Colour Doppler imaging facilitated the diagnosis of ASD in all subjects. The long-term prognosis for dogs with isolated and small-sized ASD is usually good, but can be compromised by the presence of concurrent congenital or acquired cardiac diseases.  相似文献   

2.
Congenital membranous ventricular septal aneurysm has been reported in dogs and can be associated with a perimembranous ventricular septal defect (VSD). The windsock-like ventricular septal aneurysm is formed by tissue of the membranous ventricular septum and portions of the septal leaflet of the tricuspid valve. We report two dogs that underwent transcatheter closure of perimembranous VSD associated with membranous ventricular septal aneurysm using a commercial device marketed for transcatheter closure of patent ductus arteriosus, the canine duct occluder. Partial closure was achieved in the first dog with reduction in left heart dimensions documented on echocardiography both at one day and nine months after procedure. In the second dog, three-dimensional transesophageal echocardiography, cardiac computed tomography, and a three-dimensionally printed whole heart model were used to evaluate feasibility for transcatheter device closure. Complete closure of the VSD was subsequently achieved. Both cases had good short- to medium-term outcomes, no perioperative complications were observed, and both dogs are apparently healthy and receiving no cardiac medications at 34 months and 17 months after procedure. Transcatheter attenuation of perimembranous VSD with membranous ventricular septal aneurysm is clinically feasible using the canine duct occluder, and multimodal cardiac imaging allows accurate assessment and planning prior to transcatheter intervention for structural heart disease in dogs.  相似文献   

3.
Objective: To describe surgical repair of a complete endocardial cushion defect (ECD) in a dog. Study Design: Clinical report. Animal: A 5‐month‐old, 9.2 kg male Shetland sheepdog. Methods: Echocardiographic examination revealed an ostium primum atrial septal defect (ASD), an inlet ventricular septal defect (VSD), mitral regurgitation (MR) and tricuspid regurgitation (TR), and a complete ECD was diagnosed. Surgical correction was performed using cardiopulmonary bypass (CPB) via right atriotomy. A polytetrafluoroethylene (PTFE) patch was secured along the margin of the inlet VSD using simple continuous suture, then the cleft in the septal mitral leaflet was sutured. Similarly, the cleft in the septal tricuspid leaflets was sutured. To complete inlet VSD closure, the VSD patch was secured to these sutured leaflets by simple continuous suture. Another PTFE patch was used to close the ostium primum ASD. Result: After surgery, MR, TR, and interventricular shunting were decreased. The dog was alive 6 years and 5 months after the surgery with no evidence of an interventricular shunt, TR, or other clinical signs. Conclusions: Complete ECD in a dog was corrected using a 2‐patch technique under CPB.  相似文献   

4.
ObjectiveTo describe the characteristics and outcomes of transcatheter patent ductus arteriosus (PDA) occlusion after incomplete or aborted surgical ligation in dogs and cats.AnimalsTwelve client-owned animals (11 dogs and one cat).Materials and methodsThis retrospective study describes data from animals with aborted or incomplete surgical PDA ligation that subsequently underwent transcatheter closure using endovascular methods. Patient demographics, reason for incomplete or aborted surgery, complications, and method of transcatheter occlusion were recorded. Data are presented as mean ± standard deviation or median (interquartile range), where appropriate.ResultsFor all cases, median age at surgery was 12.2 months (4.9–15.1 months) and at catheterization was 15.4 months (8.9–21.9 months), with 79 days (29–209 days) between surgical and interventional procedures. Median weight at catheterization was 4.5 kg (2.5–12.6 kg). Reasons for failed surgical ligation included hemorrhage during ductal dissection in seven dogs, residual flow in four dogs, and inability to identify the ductus in one cat. Transcatheter closure was successfully performed using a canine duct occluder in eight dogs, transarterial coil embolization in two dogs, and transvenous coil embolization in one dog and one cat. Metallic hemoclips partially obscured angiographic findings in three cases with prior surgical hemorrhage but did not prevent transcatheter closure. In all cases, ductal flow was successfully attenuated, with no or trace residual shunting on angiography and complete occlusion the following day on echocardiography.ConclusionsWhen surgery is unsuccessful, either owing to hemorrhage or residual flow, transcatheter closure of PDA is feasible, even in small patients.  相似文献   

5.
BACKGROUND: Transcatheter occlusion of patent ductus arteriosus (PDA) is a minimally invasive treatment option in dogs. Device selection based on appropriately acquired PDA dimensions and morphology can minimize procedural complications, including minimizing residual ductal flow and inappropriate embolization. HYPOTHESIS: Transesophageal echocardiographic (TEE) derived minimum ductal diameter measurements would most accurately reflect angiographic measurements. Color Doppler (CD) TEE and transthoracic echocardiographic (TTE) ductal measurements would overestimate two-dimensional (2D) measurements. ANIMALS: Fifteen client-owned dogs with PDA. METHODS: PDA dimensions obtained with angiography, 2D and CD TTE, 2D and CD TEE from the right and left views were prospectively evaluated. RESULTS: PDA dimensions were measured by using TEE most closely approximated angiographic measures. CD TTE and TEE frequently overestimated angiographic measures of minimum ductal diameter. TEE accurately identified a type III (tubular) PDA morphology in 1 dog. Fourteen of 15 dogs were determined to have hemodynamically significant reductions in left to right shunting documented by a first-pass nuclear angiocardiographic ratio of pulmonary to systemic blood flow < or = 1.2 and trivial (n = 3) to no (n = 11) CD TTE flow at approximately 1 month after PDA occlusion. CONCLUSIONS: TEE provided accurate anatomic information regarding PDA morphology and closely approximated angiographic ductal dimensions while aiding in both coil deployment and confirmation of intra-operative ductal closure.  相似文献   

6.
Ryou Tanaka  DVM  PhD    Katsuichiro Hoshi  DVM    Yukiko Nagashima  DVM    Yoko Fujii  DVM    Yoshihisa Yamane  DVM  PhD 《Veterinary surgery : VS》2001,30(6):580-584
OBJECTIVE: To describe the use of a detachable coil for transcatheter closure (TCC) of patent ductus arteriosus (PDA) in 2 dogs. STUDY DESIGN: Clinical study. ANIMALS: Two female Pembroke Welsh Corgi dogs with PDA. METHODS: Using fluoroscopic guidance, an 8-mm-diameter coil stent with 5 loops (detachable coils for PDA closure) was inserted via catheterization of the femoral artery. The catheter was passed through the PDA into the pulmonary artery. The coil was withdrawn so that 1.5 loops remained on the pulmonary side of the orifice of the ductus. The rest of the loops were pushed out from the catheter into the ductus. After confirming the correct placement of the coil and the effectiveness of the occlusion, the delivery wire was detached from the coil. RESULTS: Insertion of the coil was easily performed, even without previous experience. Immediate and marked decrease of the cardiac murmur was auscultated. Only slight residual flow was detected by angiography conducted 3 months' postoperatively. The dogs experienced quick and uneventful recovery after coil placement and required minimal postoperative care. Follow-up evaluation of the dogs showed no functional clinical signs of PDA, and no cardiac abnormalities were detected on electrocardiographic, phonocardiographic, and echocardiographic examination. In dog 1, the residual flow had disappeared on the color-flow Doppler echocardiographic examination at 18 months' postoperatively. CONCLUSION: TCC using a detachable coil was easy, safe, and effective in 2 dogs with PDA. The minimal residual shunting observed only by echocardiography seemed hemodynamically insignificant. CLINICAL RELEVANCE: This method can be used as an alternative to traditional surgical methods.  相似文献   

7.
A 2-year-old, male castrated ferret (Mustela putorius furo) was presented with progressive abdominal distention and loss of muscle mass despite normal appetite. Physical examination findings included pale mucous membranes, a prolonged capillary refill time, a pulse rate greater than 300 beats/min, and severe abdominal distention. Abdominal ultrasound showed free abdominal fluid and an enlarged liver with distended hepatic veins and caudal vena cava. During the echocardiographic examination, abnormalities observed included a 2-mm-diameter left-to-right shunting atrial septal defect (ASD) with concurrent severe dilatation of the right atrium and eccentric hypertrophy of the right ventricle with mild pulmonary hypertension. All other echocardiographic measurements were within normal limits. The owner declined treatment, and the ferret was euthanized. Postmortem examination confirmed the ultrasonographic findings. The free abdominal fluid (200 mL) was a non-septic fibropurulent exudate. Decompensated right-sided heart failure due to ASD and exudative peritonitis of undetermined origin were the final diagnoses. To our knowledge, this is the first report of an ASD in a ferret.  相似文献   

8.
Transcatheter occlusion of patent ductus arteriosus (PDA) using an Amplatz® Canine Duct Occluder (ACDO) is routinely performed in dogs. Pulmonary embolization of the device is a rarely reported complication of this procedure. We report here the first two cases of successful transcatheter retrieval of an embolized ACDO. An 8-month-old, 21-kg, German shepherd (case 1) was referred for pulmonary edema secondary to a large PDA with left-to-right shunting. After medical stabilization, an emergency procedure for PDA closure was recommended. An 8-mm ACDO was deployed under general anesthesia. The device was released after confirming its stability with a gentle tug test but migrated into the pulmonary trunk. A 10-mm ACDO was subsequently successfully deployed and released. Vascular access was then obtained from the right jugular vein so that a vascular snare could be used to capture the ACDO waist and pull it back toward the right ventricle and then the right atrium. It was then removed through the jugular vein. The dog recovered uneventfully and was discharged after confirmation of complete ductal occlusion. The same complication occurred in a second case (case 2, asymptomatic 6-month-old, 7.9-kg, cocker spaniel), and a similar procedure was used to successfully retrieve the embolized device. Both dogs are still doing well 9 and 21 months, respectively, after the procedure. These cases illustrate that transcatheter retrieval of ACDO devices embolized in the pulmonary artery using vascular snares is technically feasible in the dog.  相似文献   

9.
A 6.5-year-old male Border Collie presented for transcatheter closure of an atrial septal defect due to exercise intolerance and cyanosis while working and training at altitude. A small, left-to-right shunting secundum atrial septal defect was confirmed with no evidence of significant right-sided volume overload. Pulmonary hypertension with subsequent right-to-left interatrial shunting occurring during exercise at high altitude was suspected and prompted the closure of the defect due to the dog's continued athletic requirements. The anatomy of the defect prompted use of a patent foramen ovale occluder rather than an atrial septal defect occluder, which was deployed using a combination of fluoroscopic and transesophageal echocardiographic guidance. The owner did not report continued exercise intolerance or cyanosis and the dog's lifestyle and residence at altitude was unchanged.  相似文献   

10.
This study was designed to evaluate the feasibility and limitations of transcatheter embolization coil occlusion of patent ductus arteriosus in dogs using a carotid artery approach. Seven dogs examined at the University of California, Davis Veterinary Medical Teaching Hospital in 2002-2003 for evaluation of heart disease had congenital patent ductus arteriosus diagnosed by characteristic physical, electrocardiographic, radiographic, and anatomic and Doppler echocardiographic findings. Dogs were anesthetized for transesophageal echocardiography and transcatheter coil embolization of the ductus via the right external carotid artery. Coil embolization was achieved in all seven cases, using one to four detachable embolization coils. There were no major complications. Minor complications occurred in two dogs (additional coils placed using a femoral arterial approach and coil embolization of a left femoral artery branch). One dog was examined only 24 h post-operatively and had no murmur and trivial residual ductal flow by Doppler echocardiography. The other 6 dogs were clinically healthy when examined up to three years post-intervention. One dog had a very soft continuous murmur and mild residual ductal flow; the other five had no audible continuous murmur, with only one dog having trivial residual ductal flow identified by Doppler echocardiography. Although technically challenging, coil embolization via the carotid artery is a viable alternative approach for transcatheter closure of patent ductus arteriosus in some dogs.  相似文献   

11.
Atrial septal defect, while rare in dogs, can result in severe clinical signs. Surgical correction of atrial septal defect requires open-heart surgery. Transcatheter closure techniques provide minimally invasive surgical alternatives.  相似文献   

12.
Objective- To assess the clinical results in dogs with acetabular fractures stabilized using a screw-wire-polymethylmethacrylate (SWP) composite fixation.
Study Design- A retrospective study of client-owned dogs with acetabular fractures.
Animals- Fourteen dogs ranging in age from 4 to 95 months (mean, 34 ±25 months; median, 25 months) and body weight from 8 to 39 kg (mean, 25 ±6 kg; median, 27 kg).
Methods- Medical records and radiographs were retrospectively evaluated to determine location of the fracture, presence of preexisting degenerative joint disease, accuracy of fracture reduction and complications associated with surgery. Long-term results were evaluated by subjective assessment of lameness, elicitation of pain and/or crepitus on manipulation of the coxofemoral joint, measurements of pelvic limb circumference, coxofemoral joint goniometric measurements, and radiographic evaluation.
Results- Fracture reduction was considered anatomic in 13 dogs. At the time of the last follow-up evaluation (mean, 347 ±261 days; median, 380 days) 10 dogs were sound on the affected limb, three dogs had a subtle weight-bearing lameness of the affected limb, and the remaining dog had a consistent non-weight-bearing lameness of the affected limb. Mild (n = 10) or moderate (n = 1) degenerative changes of the affected coxofemoral joint attributed to the acetabular fracture and its repair were noted on the follow-up radiographs in 11 dogs. Limb circumference of the affected limb ranged from -8.2% to +10.8% (mean, -0.8 ±4.2%; median, -0.7%) of the contralateral limb.
Conclusions- The SWP composite fixation consistently maintained anatomic reduction, was associated with few complications, and yielded satisfactory clinical results.
Clinical Relevance- The SWP composite fixation technique would seem to be an acceptable means of stabilizing acetabular fractures in dogs.  相似文献   

13.
A left-to-right shunting muscular ventricular septal defect (VSD) was diagnosed in a 4-month-old, female, 1.8 kg Bichon Frise – poodle mix dog. Echocardiographic evidence of cardiac remodeling, calculated pulmonary blood flow (Qp) to systemic blood flow (Qs) ratio of 2.8, and radiographic evidence of pulmonary edema supported the diagnosis of a hemodynamically important VSD. Using a combination of surgery and interventional catheter-based techniques to approach the VSD through the right ventricle, the VSD was occluded with an Amplatzer® Duct Occluder (ADO) II device. The ADO II is a low profile, flexible device originally developed for patent ductus arteriosus closure in humans that has been used to close muscular and perimembranous VSD in children. This report describes the hybrid procedure and imaging that was essential for successful occlusion of the VSD in this dog.  相似文献   

14.
Left atrial tear is an infrequent sequela of severe mitral regurgitation due to myxomatous mitral valve degeneration. Interatrial septal tear due to mitral regurgitation causing a left-to-right shunt is uncommon. Right to left shunting secondary to acute interatrial septal tear is very rarely reported in the human literature, and has not been reported in the veterinary literature in a dog. This case describes the clinical, radiographic, echocardiographic, gross pathologic, and histopathologic features of a dog presented in acute respiratory distress secondary to acute onset right to left shunting through the interatrial septum. This was later documented to be due to a tear in the septum secondary to tricuspid regurgitation and pulmonary hypertension. The presence of an acquired right to left shunting atrial septal defect is of clinical and prognostic significance, and should be considered in cases of acute respiratory distress.  相似文献   

15.
A 4-month-old male French Bulldog weighing 5.0 kg (11 lb) was referred for a heart murmur. A grade 3/6 systolic murmur was detected at the left heart base and a grade 4/6 systolic murmur was detected at the right heart base. By use of color-flow Doppler ultrasonography and cardiac catheterization, a diagnosis of supracristal ventricular septal defect (VSD) with accompanying aortic regurgitation was made. Percutaneous transcatheter coil embolization was used to close the VSD. Because residual shunt was detected via echocardiography after coil implantation, the residual shunt was followed periodically via echocardiography to detect spontaneous closure of the VSD. Volume overload in the left ventricle was detected in the dog 131 days after admission. Additional coils were placed 137 days after admission. Hemolysis resulting in hemoglobinuria was detected, but this complication was mild. In the dog of this report, results of coil occlusion for correction of VSD were promising. Thus, coil occlusion should be considered as an alternative treatment for VSD in dogs.  相似文献   

16.
Background: Focal atrial tachycardia (FAT) is a common supraventricular tachycardia in dogs. Objective: To evaluate electrophysiologic characteristics and topographic distribution of FAT. Animals: Sixteen dogs with symptomatic FAT. Methods: Retrospective case series. Electrophysiological studies were performed to test the inducibility of documented and no documented arrhythmias. Once induced for each dog, FAT was analyzed for electrogenic mechanism, endocardial electrogram, and location. Results: Nineteen FATs could be studied in 16 dogs, 12 were automatic, 4 nonautomatic, and 3 incessant. Two dogs had >1 focus. Mean atrial cycle length (CL) was 238.2 ± 69.2 (SD) milliseconds, mean ventricular CL of 292.7 ± 72.5 (SD) milliseconds, with atrioventricular block in 6 cases. Mean presystolic atrial activity recorded at the ectopic focus was –39.9 ± 17.7 (SD) milliseconds. Atrial potentials were fragmented in 11 dogs and were low amplitude in 6 dogs. Sixty‐three percent of ectopic foci were distributed within the right atrium (5 crista terminalis, 3 triangle of Koch, 2 tricuspid valve annulus, 1 interatrial septum, and 1 right auricle) and 37% in the pulmonary veins (PVs) (4 right superior PV, 2 left superior PV, and 1 right inferior PV). Persistent atrial fibrillation (AF) and paroxysmal AF were triggered by FATs in 7 dogs (2 with multiple ectopic foci and 4 with at least one PV focus). Conclusion and Clinical Relevance: According to our findings, dogs have a predominance of right‐sided FAT. The majority of FATs are automatic and can trigger AF, particularly in the case of PV location.  相似文献   

17.
The purpose of this study was to evaluate the feasibility, safety, and efficacy of transcatheter closure in dogs with a congenital perimembranous ventricular septal defect (VSD) by using a detachable coil. No dogs showed any symptoms, and results of chest X-rays and ECGs were normal. The diameters of VSD ranged from 2 to 4 mm on echocardiogram. The defect was 2-2.5 mm from the aortic valve. A detachable coil (size 5 mm with 5 loops) designed for patent ductus arteriosus was delivered via the transarterial route. The device was successfully employed in all dogs. A minimal residual shunt was observed in all dogs even though Qp/Qs decreased. Hemolysis and a rate-dependent right-bundle branch block were observed in 1 dog, but there was no clinical significance. No major complication was noted. Pathologic examination after 1 year revealed that the coils were covered with tissue without significant damage to the His-Purkinje conduction system. In conclusion, transcatheter closure of a small perimembranous VSD with a detachable coil can be achieved without major complications or significant pathologic damage at the lesion site.  相似文献   

18.
Five dogs were presented to our institution for fatigue caused by an incessant supraventricular tachycardia. In all dogs, an ECG on admission showed a narrow QRS complex tachycardia with a median ventricular cycle length of 220 ms (range 180–360 ms), and a positive atrial depolarization identifiable in the ST segment following the previous QRS complex. There was a 1:1 atrioventricular conduction ratio in all but one dog, which presented with 2:1 atrioventricular block. Electrophysiologic studies identified the underlying arrhythmogenic mechanism as a right atrial macro-reentrant tachycardia with two distinct isthmic areas: right septal (RS) in three dogs and right atrial free wall (RAFW) in two dogs. Linear radiofrequency catheter ablation was performed during tachycardia in all dogs at the identified isthmic area, which acutely blocked the macroreentrant circuit. At 18-month follow-up, 3 dogs (1 with RAFW isthmus and 2 with RS isthmus) showed no recurrence of the arrhythmia on Holter monitoring. One dog with RS isthmus showed recurrence of the supraventricular tachycardia 15 days post-ablation, and 1 dog with RAFW isthmus presented with persistent atrial fibrillation 2 months post-ablation.  相似文献   

19.
OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. STUDY DESIGN: Clinical study. ANIMALS: Dogs (n=4) with continuous murmur after surgical ligation of PDA. METHODS: After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. RESULTS: Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. CONCLUSIONS: Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. CLINICAL RELEVANCE: Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.  相似文献   

20.
Background: Appropriate device selection for transcatheter occlusion of patent ductus arteriosus (PDA) is essential to procedural success. Objectives: To determine if transesophageal echocardiography (TEE) influences device selection for PDA occlusion and to report benefits, limitations, and complications associated with TEE. Animals: Twenty‐two client‐owned dogs with left‐to‐right shunting PDA. Methods: PDA dimensions were obtained via transthoracic echocardiography (TTE) and then TEE followed by angiography. Based solely on information from TTE and angiography, an initial device type and size were selected. After initial device selection, TEE measurements were disclosed and changes in device selection were recorded. After device release, angiography, TEE, or both were performed to assess occlusion. Results: An Amplatz canine duct occluder (ACDO) was securely positioned and released in 21 dogs and an embolization coil was deployed in 1 dog. Based on TEE evaluation, initial selected device type was unchanged but ACDO size was changed in 3 dogs. TEE was utilized throughout the procedure allowing real time visualization of device deployment, release and assessment of closure in 17 dogs. No complications occurred related to TEE. Complete PDA closure was achieved in all dogs. Conclusions and Clinical Importance: TEE provided anatomic information regarding PDA morphology that closely approximated angiographic ductal dimensions while aiding in device deployment, release and confirmation of closure. We conclude that TEE provides complementary anatomical and intraprocedural information and is well tolerated in dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号