首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The strength and holding power of four pin designs for use with half pin (type I) external skeletal fixation were evaluated. Pins that were tested were fully threaded, nonthreaded, two cortices partially threaded, and one cortex partially threaded. The study involved three parts: (1) resistance of the pins to axial extraction immediately after insertion; (2) resistance of the pins to axial extraction 8 weeks after being inserted into the tibiae of live dogs; and (3) resistance of the pins to bending load. Pins with threads engaging two cortices were more resistant to axial extraction than nonthreaded pins in both the acute (p less than 0.0001) and chronic (p less than 0.0001) studies. Nonthreaded pins were more resistant to bending than fully threaded and two cortices partially threaded pins (p less than 0.0005). One cortex partially threaded pins possessed similar bending strength to nonthreaded pins (p = 0.21) and had 5.3 times more resistance to axial extraction in the acute study (p less than 0.0001) and 6.9 times more in the chronic study (p less than 0.0001). Though one cortex partially threaded pins were not as resistant to axial extraction as pins with threads engaging two cortices (p less than 0.0001), they were more resistant to bending loads (p less than 0.0005). Loss of holding power and pin failure are two of the most serious problems associated with fracture stabilization using external skeletal fixation. The results of this study suggest that one cortex partially threaded pins are better at maintaining holding power and resisting bending and breaking than nonthreaded pins.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
OBJECTIVE: To evaluate in vitro holding power and associated microstructural and thermal damage from placement of positive-profile transfixation pins in the diaphysis and metaphysis of the equine third metacarpal bone. SAMPLE POPULATION: Third metacarpal bones from 30 pairs of adult equine cadavers. PROCEDURE: Centrally threaded positive-profile transfixation pins were placed in the diaphysis of 1 metacarpal bone and the metaphysis of the opposite metacarpal bone of 15 pairs of bones. Tensile force at failure for axial extraction was measured with a materials testing system. An additional 15 pairs of metacarpal bones were tested similarly following cyclic loading. Microstructural damage was evaluated via scanning electron microscopy in another 6 pairs of metacarpal bones, 2 pairs in each of the following 3 groups: metacarpal bones with tapped holes and without transfixation pin placement, metacarpal bones following transfixation pin placement, and metacarpal bones following transfixation pin placement and cyclic loading. Temperature of the hardware was measured with a surface thermocouple in 12 additional metacarpal bones warmed to 38 C. RESULTS: The diaphysis provided significantly greater resistance to axial extraction than the metaphysis. There were no significant temperature differences between diaphyseal and metaphyseal placement. Microstructural damage was limited to occasional microfractures seen only in cortical bone of diaphyseal and metaphyseal locations. Microfractures originated during drilling and tapping but did not worsen following transfixation pin placement or cyclic loading. CONCLUSIONS AND CLINICAL RELEVANCE: Centrally threaded, positive-profile transfixation pins have greater resistance to axial extraction in the diaphysis than in the metaphysis of equine third metacarpal bone in vitro. This information may be used to create more stable external skeletal fixation in horses with fractures.  相似文献   

3.
OBJECTIVE: To compare the in vitro holding power and associated microstructural damage of 2 large-animal centrally threaded positive-profile transfixation pins in the diaphysis of the equine third metacarpal bone. SAMPLE POPULATION: 25 pairs of adult equine cadaver metacarpal bones. PROCEDURE: Centrally threaded positive-profile transfixation pins of 2 different designs (ie, self-drilling, self-tapping [SDST] vs nonself-drilling, nonself-tapping [NDNT] transfixation pins) were inserted into the middiaphysis of adult equine metacarpal bones. Temperature of the hardware was measured during each step of insertion with a surface thermocouple. Bone and cortical width, transfixation pin placement, and cortical damage were assessed radiographically. Resistance to axial extraction before and after cyclic loading was measured using a material testing system. Microstructural damage caused by transfixation pin insertion was evaluated by scanning electron microscopy. RESULTS: The temperature following pin insertion was significantly higher for SDST transfixation pins. Periosteal surface cortical fractures were found in 50% of the bones with SDST transfixation pins and in none with NDNT transfixation pins. The NDNT transfixation pins were significantly more resistant to axial extraction than SDST transfixation pins. Grossly and microscopically, NDNT transfixation pins created less damage to the bone and a more consistent thread pattern. CONCLUSIONS AND CLINICAL RELEVANCE: In vitro analysis revealed that insertion of NDNT transfixation pins cause less macroscopic and microscopic damage to the bone than SDST transfixation pins. The NDNT transfixation pins have a greater pull out strength, reflecting better initial bone transfixation pin stability.  相似文献   

4.
Objective —To measure pullout strength of four pin types in avian humeri and tibiotarsi bones and to compare slow-speed power and hand insertion methods.
Study Design —Axial pin extraction was measured in vitro in avian bones.
Animal Population —Four cadaver red-tailed hawks and 12 live red-tailed hawks.
Methods —The pullout strength of four fixator pin designs was measured: smooth, negative profile threaded pins engaging one or two cortices and positive profile threaded pins. Part 1: Pins were placed in humeri and tibiotarsi after soft tissue removal. Part 2: Pins were placed in tibiotarsi in anesthetized hawks using slow-speed power or hand insertion.
Results —All threaded pins, regardless of pin design, had greater pullout strength than smooth pins in all parts of the study ( P < .0001). The cortices of tibiotarsi were thicker than the cortices of humeri ( P < .0001). There were few differences in pin pullout strengths between threaded pin types within or between bone groups. There were no differences between the pullout strength of pins placed by slow-speed power or by hand.
Conclusions —There is little advantage of one threaded pin type over another in avian humeri and tibiotarsi using currently available pin designs. There were few differences in pin pullout strengths between humeri and tibiotarsi bones. It is possible that the ease of hand insertion in thin cortices minimizes the potential for wobbling and therefore minimizes the difference between slow-speed drill and hand insertion methods.
Clinical Relevance —Threaded pins have superior bone holding strength in avian cortices and may be beneficial for use with external fixation devices in birds.  相似文献   

5.
The holding power of orthopedic screws in the third metacarpal and metatarsal cadaver bones of foals that were aged from 1 to 14 days was tested. Comparative trials between screws inserted at the same site in contralateral bones from the same foal were performed to compare the holding power of 5.5 mm cortical and 6.5 mm cancellous screws in the metaphysis, and the holding power of 5.5 and 4.5 mm cortical screws in the diaphysis. A MTS servohydraulic tensile testing machine was used to perform screw pullouts at a displacement rate of 19 mm/sec. There was no significant difference between maximum holding power of 5.5 mm cortical screws and 6.5 mm cancellous screws in the metaphysis when expressed as kg per mm of bone width at the screw insertion site (p = 0.097) or as kg per mm of screw thread engaged in the bone (p = 0.17). There was no significant difference in holding power of 5.5 and 6.5 mm screws in the proximal versus distal metaphysis (p = 0.10). The 5.5 mm screws had significantly greater holding power than the 4.5 mm screws in the diaphysis (p = 0.0097). Fixation failure at screw pullout was always due to bone shear. In internal fixation in foal bone, the 5.5 mm screws may be a suitable alternative to 6.5 mm screws in the metaphysis. Use of 5.5 mm rather than 4.5 mm screws is recommended in the diaphysis because of greater holding power.  相似文献   

6.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   

7.
Smooth and partially threaded 3.12 mm (1/8 inch) trochar-tipped Steinmann pins were inserted transversely through both diaphyseal cortices of eight mature canine tibias using five methods. Angular velocity (revolutions per minute) during insertion and temperature elevation due to friction during penetration of the second cortex were recorded. The force required for extraction of the pins from the bone and the histologic appearance of the bone-pin interface were determined for one-half of the pins 2 days after insertion and for one-half of the pins 56 days after insertion. The increase in temperature was similar for all methods of insertion except high speed power, which was significantly greater (p < 0.05). The force required for axial pin extraction was similar for pins inserted by hand chuck, predrilled, and low speed power methods after both 2 and 56 days. Pins inserted by high speed power and hand drill required force similar to the others for extraction after 2 days but significantly less force (p < 0.05) for extraction after 56 days. The partially threaded pins required significantly greater force (p < 0.01) extraction after both 2 and 56 days. Histologic examination revealed increased mechanical bone damage surrounding hand chuck inserted pins, increased bone necrosis surrounding high speed power inserted pins, and increased inflammatory changes surrounding hand drill inserted pins.  相似文献   

8.
This study tested the hypothesis that two-way insertion of an external skeletal fixator trans-fixation pin would weaken the pin-bone interface. Smooth and partially threaded (end) trans-fixation pins were placed in tibiae of 32 cadavers by slow speed drilling or hand placement through a predrilled pilot hole. In one bone of each tibial pair, pins were inserted 2 cm beyond the distal cortex and retracted to a predetermined position (two-way). In the contralateral limb, the pins were inserted in one forward motion to the predetermined position (one-way). The peak force (Newtons) required to extract the pins (pull-out strength) axially at a rate of 1 mm/sec was determined by using a universal testing machine. A significant (p < .05) decrease in pull-out strength was found in pins placed by two-way insertion (674 +/- 410) as opposed to one-way insertion (766 +/- 432). The results of this in vitro study suggest that one-way insertion should be used clinically to decrease weakening of the pin-bone interface and prevent possible failure of external fixators. A significantly greater pull-out strength was found for threaded pins placed in the proximal diaphysis (1459 +/- 330 Newtons) compared to the distal metaphysis (873 +/- 297 Newtons).  相似文献   

9.
External skeletal fixation is generally considered the best stabilization technique for immobilizing avian long bone fractures, but one of its major complications is the failure of bone-fixation pin interface or the loss of holding power. Consequently, this study is aimed at elucidating which pin design offers more pull-out strength in certain bones of the common buzzard (Buteo buteo). To achieve this objective, three pin designs (a smooth design and two negative profile threaded designs, with different thread pitch) were placed in five positions along the femur and ulna of the common buzzard. The pin pull-out strength was measured with the purpose of comparing medullary and pneumatic bones, insertion sites, and pin designs. Threaded pins with negative profile showed greater holding power than smooth pins (P < 0.05). When comparing holding power between the ulna and femur, no differences were found for smooth pins, whereas threaded pins showed more pull-out strength in the ulna than in the femur (P < 0.05). There were no differences observed related to pin location along the same bone when considering the same pin type. These results suggest that negative profile threaded pins have more holding power than smooth pins and that pneumatic bones provide less pull-out strength to negative profile threaded pins than medullary bones.  相似文献   

10.
Intramedullary pressure in canine long bones   总被引:1,自引:0,他引:1  
Intramedullary pressure was measured bilaterally in 36 dogs: in the diaphysis and distal metaphysis of the femur, in the proximal metaphysis of the tibia and humerus, and in the diaphysis of the radius. Pressure measurements were repeated in 5 dogs, 14 days after the initial recordings. Mean (+/- SD) pressures in the femoral diaphysis and distal metaphysis were 27.6 (+/- 15.4) mm of Hg and 17.6 (+/- 10.5) mm of Hg, respectively. Mean (+/- SD) pressures in the tibial diaphysis and proximal metaphysis were 26.4 (+/- 13.0) mm of Hg and 17.9 (+/- 11.8) mm of Hg, respectively. Mean (+/- SD) pressures in the humeral diaphysis and proximal metaphysis were 26.2 (+/- 15.8) mm of Hg and 13.4 (+/- 7.7) mm of Hg, respectively. The mean (+/- SD) pressure in the radial diaphysis was 15.4 (+/- 18.9) mm of Hg. Metaphyseal pressure was significantly (P less than 0.05) lower than diaphyseal pressure. Repeated pressure measurements in 5 dogs did not vary significantly from initial values, suggesting that the wide range of pressure was real not artifactual.  相似文献   

11.
Intramedullary fully-threaded pins were manufactured from an alloy of titanium, aluminium and vanadium in a fully-threaded style. Pins were produced in various diameters, ranging from 4 mm to 11 mm. Pin lengths varied from 5 cm to 22 cm. The proximal end of the pins was designed to fit into a hexagonal screwdriver, while the distal end was slightly tapered to allow for ease of entry into cancellous bone. Treatment using the fully-threaded intra- medullary pin was carried out in a total of 175 fractures of the humerus, femur, and tibia in 95 cats (bilateral femur in 1 case) and 77 dogs (bilateral femur in 2 cases). Radiographic follow-up for the cases was performed at monthly intervals. Non-union developed in one dog with a femoral fracture in which cerclage wire had also been used. Delayed healing and lameness were observed in two other dogs. Healing with excessive callus formation was observed in 16 dogs. However, there were not any problems noted in these dogs in regards to limb usage. Clinical and radiological results obtained for the remaining cases were found to be very good. Normal, complete fracture healing occurred between four to 14 weeks in dogs, and between four to 12 weeks in cats. Pins were removed upon observation of satisfactory functional and radiographic recovery. Pins could not be removed from 26 cats and 21 dogs as the owners had declined pin removal, or because the owners were lost to follow-up.  相似文献   

12.
OBJECTIVE: To compare the microstructural damage created in bone by pins with lathe-cut and rolled-on threads, and to determine the peak tip temperature and damage created by positive-profile external fixator pins with either hollow ground (HG) or trocar (T) tips during insertion. STUDY DESIGN: An acute, in vitro biomechanical evaluation. SAMPLE POPULATION: Twenty-seven canine tibiae. METHODS: Lathe-cut thread design with T point (LT-T), rolled-on thread design with T point (RT-T), and rolled-on thread design with HG point (RT-HG) pins were evaluated. Twenty pins of each type were inserted under constant drilling pressure into 12 canine tibiae (12 diaphyseal and 8 metaphyseal sites per pin type). Peak pin tip temperature, drilling energy, end-insertional pin torque, and pullout force were measured for each pin. For the histologic study, five pins of each type were inserted into cortical and cancellous sites in 15 additional tibiae. Entry and exit damage, and thread quality were assessed from 100 micron histologic sections by using computer-interfaced videomicroscopy. RESULTS: T-tipped pins reached higher tip temperature in both diaphyseal and metaphyseal bone compared with HG-tipped pins. RT-T pins had higher pullout strength (diaphyseal) and end-insertional torque compared with other combinations. No differences in drilling energy or insertional bone damage was found between the three pin types (P < .05). CONCLUSIONS: T-tipped pins mechanically outperformed HG-tipped pins. Pin tip and thread design did not significantly influence the degree of insertional bone damage. CLINICAL RELEVANCE: T-tipped pins may provide the best compromise between thermal damage and interface friction for maximizing performance of threaded external fixator pins.  相似文献   

13.
OBJECTIVE: To characterize the mechanical performance of a veterinary bone anchor under static and cyclic loads. STUDY DESIGN: Mechanical testing study. ANIMALS: Cadaveric canine humeri. METHODS: Humeri (6 pairs) were collected from skeletally mature dogs (mean [+/-SD] age, 17.2+/-2.1 months; weight, 20.8+/-1.5 kg). Bone anchors were inserted in the proximal metaphysis using nylon, and were longitudinally extracted. For the opposite humerus, anchors were subjected to longitudinal cyclic load (50% of the load at failure of their pair) for 1200 cycles then longitudinally loaded to failure. Anchors were then installed in a similar and adjacent area of these 2(nd) humeri with nylon and cyclically tested perpendicular to the axis of anchor insertion (100% of the longitudinal holding power of their pair) for 1200 cycles, then perpendicularly loaded to failure. Paired t-tests were used to compare holding power before and after longitudinal cyclic testing. RESULTS: Longitudinal holding power of the screw-type anchor in the proximal humerus was 385+/-30 N. Anchor pullout was the only mode of failure. Anchors in the paired humeri did not fail after 1200 cycles of 50% longitudinal loading, and post-cycle holding strength was not different (335+/-87 N; P=.32). Perpendicularly loaded anchors did not fail after 1200 cycles of 100% of opposite longitudinal holding strength, and had post-cycle perpendicular holding strengths of 514+/-72 N. Suture breakage was the mode of failure. CLINICAL RELEVANCE: Bone anchor holding strength is dependent on orientation of suture load. Screw-type bone anchor holding strength was not affected by longitudinal cyclic loading, and holding strengths of approximately 385 N can be expected in metaphyseal bone of large-breed mature dogs. Perpendicularly loaded anchors have higher failure loads, and holding strength of approximately 514 N can be expected in metaphyseal bone of the proximal humerus.  相似文献   

14.
C Riddell 《Avian diseases》1975,19(3):490-496
The growth rate of the tibiotarsus, tarsometatarsus, and humerus was studied in two strains of chickens selected for a high and low incidence of tibial dyschondroplasia. The proximal growth plates grew more rapidly than the distal growth plates. The proximal growth plate of the tibiotarsus grew fastest, while those of the tarsometatarsus and humerus had growth rates that were respectively 4 and 33% slower. The bones averaged slightly faster growth in the high-incidence strain than in the low-incidence strain. A slowed growth decreased the incidence of tibial dyschondroplasia. However, lack of correlation between growth rate and the development of tibial dyschondroplasia in individual chickens suggested that growth rate may be no more than a contributing factor.  相似文献   

15.
Medical records of 12 calves less than or equal to 1 month old, with fracture of the femoral diaphysis, were reviewed. Ten calves were within 1 week of birth at the time of diagnosis. Open reduction was accomplished by use of a lateral approach. Retrograde intramedullary pinning was accomplished in all calves, using 2 (n = 4 calves) or 3 (n = 8 calves) pins. Cerclage wire was used to supplement fixation in 7 calves. A closed continuous suction drain was placed along the lateral aspect of the femur in every calf. Postsurgical complications included seroma formation over the middle gluteal musculature (n = 5 calves), pin migration (n = 6 calves), and osteomyelitis (n = 1 calf). Pin migration was observed in 4 calves that had been treated with nonthreaded trochar point pins. Fractures in 10 of 12 calves (83%) were considered to have healed satisfactorily. One calf was euthanatized because of septic osteomyelitis of the femur. One calf was euthanatized because of persistent lameness and pin migration. Pins were removed in 8 of 12 calves (67%) between the 13th and 90th postoperative days. Results of this study indicate that application of intramedullary pins may be a useful solution for management of femoral diaphyseal fracture in young calves.  相似文献   

16.
Objective— To report development, configuration, application, and results of a tapered‐sleeve transcortical pin external skeletal fixation device (TSP ESFD) for use on fractures of the distal aspect of the equine limb. Study Design— Optimization analysis of a TSP ESFD was carried out with mechanical testing and review of clinical case outcomes. Animals— Cadaveric adult third metacarpal bones (MC3) for mechanical testing; horses (n=7) with severely comminuted proximal (6; P1) or second (1) phalanx fractures. Methods— Mechanical testing of methods for attachment of TSP to the sidebars were tested as well as optimization of pin diameters. Outcome of clinical cases managed with the TSP ESFD were compared with outcomes of horses treated with previous ESFD. Results— A TSP ESFD using 7.94 mm diameter pins was used. Survival rate was 71%. One horse with an infected P1 fracture and contralateral laminitis subsequently fractured MC3 through the distal pin hole while wearing the TSP ESFD. One mare with contralateral laminitis was euthanatized. Three horses had open fractures. Conclusions— Design improvements incorporated into the TSP ESFD should increase treatment success. Clinical Relevance— External skeletal fixation continues to be a viable treatment alternative for severe injuries of the distal aspect of the equine limb. TSP ESFD should improve on the success of treatment by decreasing complications of bone fracture at the pin interface.  相似文献   

17.
OBJECTIVE: To investigate the effectiveness of intramedullary xenograft cortical bone pins compared with stainless steel Kirschner wire for the repair of a standardized avian humeral fracture. STUDY DESIGN: Prospective randomized study. SAMPLE POPULATION: Thirty mature pigeons (Columba livia). METHODS: Birds were randomly assigned to 3 groups. Transverse mid-diaphyseal humeral fractures were created in 1 humerus in each bird. Fractures were stabilized with intramedullary ostrich or canine xenograft cortical bone pins or Kirschner wire. Radiographic, histological, and biomechanical assessments were used to compare fracture healing 6 weeks after fracture stabilization. The contralateral humerus of each bird was used as a control. RESULTS: All fractures healed regardless of intramedullary pin type. There were no statistically significant biomechanical differences among groups or within groups. Xenograft cortical bone pins induced a mononuclear inflammatory reaction that did not impair bone healing. Bones stabilized with intramedullary cortical bone pins had more periosteal callus and inflammation at the fracture site than bones stabilized with stainless steel Kirschner wires. CONCLUSIONS: Intramedullary xenograft cortical bone pins, derived from mammalian or avian sources, appear to represent an alternative for the repair of avian humeral fractures. CLINICAL RELEVANCE: Intramedullary xenograft cortical bone pins are biodegradable and may reduce the need for additional surgery to remove implants after fracture healing.  相似文献   

18.
The effects of three different techniques of intramedullary (IM) pin placement on pin location and incidence of stifle joint injury were evaluated using 70 cadaver canine tibiae after middisphyseal osteotomy. In 50 tibiae, pins were placed retrograde in either a nondirected (group A) or a craniomedially directed fashion (group B) with 25 tibiae in each group. Pins were driven normograde (group N) in 20 tibiae. All the stifles were dissected to qualitatively evaluate pin interference with different joint structures. End-on radiographs of the tibial plateaus were used to quantitatively evaluate pin location. Interference with the caudal cruciate ligament, medial meniscus, lateral meniscus, or meniscal ligaments was not observed in any group. There was a significant association between pinning technique and incidence of involvement of the cranial cruciate ligament ( P < .005), patella ( P < .001), patellar ligament ( P < .005), and femoral condyle ( P < .01). Pin location for group A was significantly different from either other group in a cranial-caudal direction ( P = .003), and was significantly different from group N in a medial-lateral direction ( P = .005). No significant difference was observed between pin location for groups B and N in either plane. It was concluded that although nondirected retrograde pinning cannot be recommended, retrograde pins directed craniomedially may be an acceptable technique for the repair of proximal to mid-diaphyseal tibial fractures if care is taken to properly seat the pins.  相似文献   

19.
Thirteen feline humeral fractures were stabilised using external skeletal fixation alone or in combination with supplementary devices. Eleven of the 13 fractures healed. Pins placed in the distal humerus should be angled to avoid the supracondylar foramen and radial nerve. An intramedullary pin in combination with external skeletal fixation is indicated for mildly comminuted reconstructable fractures. For severely comminuted humeral fractures, closed application of an external skeletal fixator may be preferable to open reduction and internal fixation to provide healing and is recommended as an alternative to amputation.  相似文献   

20.
OBJECTIVE: To evaluate stiffness and bone-pin interface stress for a transcortical tapered-sleeve pin (TSP) that incorporates bilateral tapered sleeves over a transcortical pin. SAMPLE POPULATION: 14 third metacarpal bones (MCIII) collected from adult horses of various breeds. PROCEDURE: Each MCIII was cut in half to provide 2 test specimens. Pins (conventional and TSP) of 3 diameters (6.35, 7.94, and 9.50 mm) were inserted in specimens (3 specimens for each diameter and each type of pin). The test fixture simulated a typical sidebar-span skeletal fixation device for horses. Single cycle load-deflection tests were performed. Cyclic fatigue tests of TSP were performed to evaluate fatigue characteristics and stress conditions at the bone-pin interface. Maximum stress and strain were calculated, and results were compared with existing data on fatigue characteristics of bone. RESULTS: Significant increases in stiffness (load-deflection) and higher loads at yield point were detected for the TSP (stiffness for conventional 9.50mm pins, 4,500 N/mm; stiffness for TSP, 19,988 N/mm). Results of cyclic tests revealed a close correlation with existing data on fatigue characteristics. CONCLUSIONS AND CLINICAL RELEVANCE: The TSP described here is stiffer than conventional transcortical pins, and stress across the bone-pin interface is more evenly distributed. Use of this TSP should minimize major problems encountered during external fixation associated with the transcortical pin and bone-pin interface (ie, bone necrosis, infection of the pin track, pin loosening, and bone failure).  相似文献   