首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Balloon valvuloplasty was performed on two dogs with pulmonic valve stenosis. Immediately following balloon valvuloplasty, peak right ventricular systolic pressure declined from 92 to 44 mm Hg in the first dog and from 108 to 46 mm Hg in the second dog. The peak systolic pressure gradient across the pulmonic valve declined from 60 to 12 mm Hg in the first dog and from 84 to 22 mm Hg in the second dog. Hemodynamic improvement was sustained in both dogs at the time of recatheterization 3 months later. Both dogs tolerated the procedure well and there were no serious complications. It was concluded that balloon valvuloplasty offers an alternative to surgery for the treatment of valvular pulmonic stenosis in dogs. The exact indications for and limitations of balloon valvuloplasty must await the results of additional and more long-term studies.  相似文献   

2.
OBJECTIVE: To compare outcome and intermediate-term survival for dogs undergoing open surgical correction of subvalvular aortic stenosis (SAS) with those for dogs with SAS that did not undergo surgery. DESIGN: Retrospective study. ANIMALS: 44 dogs with congenital SAS. PROCEDURE: Maximum instantaneous systolic pressure gradients were determined by use of Doppler echocardiography. Cardiopulmonary bypass and open surgical correction of SAS (membranectomy with or without septal myectomy) was performed in 22 dogs, whereas 22 dogs did not undergo surgical correction. Cumulative survival was compared between surgical and nonsurgical groups, using Kaplan-Meier nonparametric analysis and a Mantel-Cox log-rank test. RESULTS: Initial systolic pressure gradients were not significantly different for dogs undergoing surgery (128 +/- 55 mm Hg), compared with those that did not undergo surgery (117 +/- 57 mm Hg). Systolic pressure gradients were significantly decreased after surgery in dogs that underwent surgery (54 +/- 27 mm Hg). Cumulative survival was not significantly different between dogs in the surgical and nonsurgical groups. Censoring surgery-related mortality in the analysis still did not reveal a significant difference in cumulative survival between the surgical and nonsurgical groups. CONCLUSIONS AND CLINICAL RELEVANCE: Despite reductions in the systolic pressure gradient and possible associated improvement in exercise tolerance, a palliative benefit on survival was not documented in dogs undergoing surgery for SAS.  相似文献   

3.
Balloon dilation during cardiac catheterization was evaluated for the treatment of congenital subaortic stenosis (SAS) in nine dogs. Under general anesthesia, bilateral cardiac catheterization was performed through the right jugular vein and carotid artery. Thermodilution cardiac output, and left ventricular and aortic root pressures and angiograms were obtained before and after balloon dilation. Balloons measuring 18–20 mm in diameter and 30–40 mm in length were positioned across the stenosis and three inflations 4–5 minutes apart were performed. There was no significant change in cardiac output, aortic pressure, or degree of aortic regurgitation after balloon dilation. For the entire group balloon dilation resulted in significant decreases in left ventricular systolic pressure (-61.2 ± 37.2 mm Hg [mean change ± SD], range -14 to -123), mean systolic pressure gradient (-39.6 ± 24.4 mm Hg, range –8.4 to -72.2), and peak systolic pressure gradient (-64.3 ± 46.5 mm Hg, range –17 to –143). Calculated left ventricular outflow cross-sectional area increased significantly (+.4 ± .5 cm2, range –.06 to + 1.30). Clinical signs improved in the five symptomatic dogs. Individual hemodynamic responses varied widely, but the magnitude of improvement correlated with the severity of obstruction. Three dogs showed a decrease of 60% or greater (≥100 mm Hg), and six dogs showed a decrease of 25–50% (17–71 mm Hg) in peak systolic gradient after balloon dilation. Complications were frequent but most were transient and manageable. These preliminary results suggest that balloon dilation can acutely decrease outflow resistance in dogs with SAS and may be effective therapy for some affected dogs.  相似文献   

4.
The records of 43 dogs presenting with severe pulmonic stenosis in which balloon valvuloplasty was attempted were reviewed. Thirty-four dogs (79 per cent) were symptomatic at initial presentation. All patients were selected for balloon valvuloplasty on the basis of a Doppler-derived trans-stenotic pressure gradient of over 80 mmHg and concurrent evidence of mild to severe right ventricular hypertrophy. Forty dogs underwent balloon valvuloplasty; the procedure was not performed in three dogs because of an aberrant coronary artery in two cases and because catheterisation of the pulmonary artery was not possible in the third. Overall, 37 out of the 40 dogs (93 per cent) were successfully ballooned, resulting in a mean reduction in the pressure gradient of 46 per cent, with a mean pressure gradient of 124 mmHg on presentation and 67 mmHg six months after the procedure. Three dogs died during balloon valvuloplasty (all of which had a concurrent defect) and three dogs showed a poor clinical response to the procedure. Thus balloon valvuloplasty was successful and resulted in a sustained clinical improvement in 80 per cent of previously symptomatic cases. This study was undertaken to document the results of balloon valvuloplasty in a larger population of dogs than has previously been published.  相似文献   

5.
Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some ‘tips’ for successful percutaneous subaortic balloon valvuloplasty.  相似文献   

6.
Medical records of 81 dogs with severe pulmonic stenosis from 2 referral centers were examined retrospectively. Forty dogs underwent balloon valvuloplasty (BV), which was performed by 1 operator, whereas 41 did not. The mean age at latest follow-up was 41.5 months. A statistical comparison of the clinical outcome and survival was performed. Dogs revealing clinical signs at presentation showed a 16-fold increase in risk of death compared with asymptomatic dogs (P < .001). Statistical analyses demonstrated that an increase of 1 mm Hg in transstenotic pressure gradient (PG) at presentation was associated with a 3% increase in hazard rate (P < .001). Thirty-seven dogs survived BV with a median reduction in PG of 46%. The median preoperative PG was 120 mm Hg, and median PG 24 hours postoperatively was 55 mm Hg with a median of 55 mm Hg 6 months post-BV. Twenty (49%) of the non-BV (NBV) dogs remained asymptomatic at last follow-up. Fourteen (34%) of the NBV dogs died or were euthanized because of heart disease related to pulmonic stenosis. Twelve of these dogs died suddenly, whereas only 1 of the BV dogs died suddenly. After adjusting for PG, clinical signs at presentation, and age, BV or dilation was associated with a 53% reduction in hazard rate (P = .005). This study indicates that BV, when performed by an experienced operator, appears to be successful both in alleviating clinical signs and in prolonging survival in dogs with severe pulmonic stenosis.  相似文献   

7.
Discrete subvalvular aortic stenosis with peak systolic pressure gradients of more than 60 mm Hg was treated by closed transventricular dilation in six young dogs. Peak systolic pressure gradients were measured by direct catheterization before surgery, immediately after dilation, and 3 months after surgery. Maximum instantaneous pressure gradients were measured by continuous wave Doppler echocardiography before surgery and 6 weeks to 9 months after surgery. All dogs survived the procedure, and two dogs were clinically normal after 9 and 14 months. Two dogs died at week 6 and month 7. One dog was receiving medication for pulmonary edema 15 months after surgery. One dog underwent open resection of the subvalvular ring at month 3, and was clinically normal 6 months after the second procedure. Complications included intraoperative ventricular fibrillation in one dog, and mild postoperative aortic insufficiency in one dog. Closed transventricular dilation resulted in an immediate 83% decrease in the peak systolic pressure gradient from a preoperative mean of 97 +/- 22 mm Hg to a mean of 14 +/- 15 mm Hg. However, systolic pressure gradients measured by direct catheterization at month 3 (77 +/- 26 mm Hg), and by Doppler echocardiography at week 6 to month 9 (85 +/- 32 mm Hg) were not significantly different from preoperative values, which suggested recurrence of the aortic stenosis. Closed transventricular dilation should not be considered a definitive treatment for discrete subvalvular aortic stenosis in dogs, but may be useful in young dogs with critical aortic stenosis as a bridge to more definitive surgery.  相似文献   

8.
The Natural Clinical History of Canine Congenital Subaortic Stenosis   总被引:1,自引:1,他引:0  
The demographics and natural clinical history of canine congenital subaortic stenosis (SAS) were evaluated by retrospective analysis of 195 confirmed cases (1967 to 1991), 96 of which were untreated and available for follow-up evaluation. Of these, 58 dogs had left ventricular outflow systolic pressure gradients available for assessment of severity. All 195 dogs were used for demographic analysis. Breeds found to be at increased relative risk included the Newfoundland (odds ratio, 88.1; P < .001), Rottweiler (odds ratio, 19.3; P < .001), Boxer (odds ratio, 8.6; P < .001), and Golden Retriever (odds ratio, 5.5; P < .001). Dogs with mild gradients (16 to 35 mm Hg) and those that developed infective endocarditis or left heart failure were diagnosed at older ages than those with moderate (36 to 80 mm Hg) and severe (>80 mm Hg) gradients. Of 96 untreated dogs, 32 (33.3%) had signs of illness varying from fatigue to syncope; 11 dogs (11.3%) developed infective endocarditis or left heart failure. Exercise intolerance or fatigue was reported in 22 dogs, syncope in 11 dogs, and respiratory signs (cough, dyspnea, tachypnea) in 9 dogs. In addition, 21 dogs (21.9%) died suddenly. Sudden death occurred mainly in the first 3 years of life, primarily but not exclusively, in dogs with severe obstructions (gradient, > 80 mm Hg; odds ratio, 16.0; P < .001). Infective endocarditis (6.3%) and left heart failure (7.3%) tended to occur later in life and in dogs with mild to moderate obstructions. Left heart failure was uncommon in the absence of additional congenital defects or infective endocarditis. Dogs with mild obstructions lived longer than other groups and tended to remain asymptomatic. The majority of dogs with severe obstructions died before 3 years of age and had a high prevalence (8 of 15) of sudden death. The prognosis for long-term survival in dogs with untreated mild or moderate SAS is favorable (median survival, 30.5 and 51.1 months, respectively), while the prognosis for dogs with severe SAS is very poor (median survival, 18.9 months).  相似文献   

9.
CASE DESCRIPTION: A 5-year-old male German Shepherd Dog was evaluated because of a 5-month history of progressive lethargy, weight loss, and heart failure. CLINICAL FINDINGS: On physical examination, bounding femoral pulses and systolic and diastolic murmurs were detected. Echocardiography revealed severe aortic valve insufficiency (AVI) and a large vegetative lesion on the aortic valve consistent with aortic valve endocarditis. The AVI velocity profile half-time was 130 milliseconds; the calculated peak systolic pressure gradient across the aortic valve was 64 mm Hg. Left ventricular diameter during diastole was 63.6 mm (predicted range, 40.2 to 42 mm) and during systole was 42.9 mm (predicted range, 25.4 to 27 mm). Systolic, diastolic, and mean arterial blood pressures were 120, 43, and 65 mm Hg, respectively. TREATMENT AND OUTCOME: To palliate severe AVI, the descending aorta was occluded (duration, 16.75 minutes) and heterotopic implantation of a porcine bioprosthetic heart valve in that vessel was performed. After surgery, systolic, diastolic, and mean arterial blood pressures were 115, 30, and 61 mm Hg, respectively, in the forelimb and 110, 62, and 77 mm Hg, respectively, in the hind limb. Within 6 months, the AVI velocity profile half-time had increased to 210 milliseconds, indicating diminished severity of AVI. After 24 months, the dog was able to engage in vigorous exercise; no pulmonary edema had developed since surgery. CLINICAL RELEVANCE: Heterotopic bioprosthetic heart valve implantation into the descending aorta during brief aortic occlusion appears feasible in dogs and may provide substantial palliation for dogs with severe AVI.  相似文献   

10.
Introduction/objectivesPulmonary artery dissection is a rare complication following balloon valvuloplasty for pulmonic stenosis. We sought to report the rate of this complication in dogs and describe the demographic, clinical, procedural, and outcome data in affected dogs.Animals, materials and methodsMedical records at a single academic institution between 2002 and 2021 were reviewed for dogs with pulmonic stenosis treated by a balloon valvuloplasty. Dogs were included for evaluation if there was evidence of pulmonary artery dissection on echocardiography or necropsy following balloon valvuloplasty. The demographic, clinical, surgical, and follow-up information were then recorded.ResultsSix dogs were included from 210 balloon valvuloplasty procedures for pulmonic stenosis giving a 3.9% rate of pulmonary dissection. There was a variety of signalment, pulmonary valve morphologies, and balloon catheter types used in each dog. All dogs had severe pulmonic stenosis (median pressure gradient of 208 mmHg, range 94–220 mmHg) with 5/6 dogs having a pressure gradient >144 mmHg. The median balloon to pulmonary valve annulus ratio was 1.35 (range 1.25–1.5). Three dogs died perioperatively, and three dogs were alive at follow up 3.3, 4.0, and 4.1 years postoperatively.ConclusionPulmonary artery dissection is a rare complication following balloon valvuloplasty for pulmonic stenosis. Extreme elevations in preoperative pulmonary valve flow velocity were common. Prognosis is variable, with a potential 50% perioperative survival rate, but extended survival times were noted in those patients discharged from hospital.  相似文献   

11.
Radiographic, echocardiographic, fluoroscopic, and angiographic images from 2 dogs with severe congenital mitral valve stenosis that underwent cardiac catheterization and balloon valvuloplasty are presented. Both dogs displayed systolic doming of the mitral valve leaflets, increased diastolic pressure gradient across the left atrium and ventricle, and decreased mitral inflow E to F slope. Balloon valvuloplasty was performed on both dogs using atrial transeptal puncture.  相似文献   

12.
OBJECTIVE: To determine arterial blood pressure in client-owned dogs, using direct arterial puncture, oscillometry, and Doppler ultrasonography in a clinical setting. DESIGN: Prospective study. ANIMALS: 8 clinically normal client-owned dogs. PROCEDURE: Blood pressures of nonsedated dogs were measured simultaneously, using each of the 3 methods. Mean values obtained were compared with published mean values. Ability of noninvasive methods (Doppler ultrasonography and oscillometry) to accurately predict results of the invasive method, and relationships between blood pressure and age, body weight, and degree of patient anxiety were determined. RESULTS: Calculated ranges of values (mean +/- 2 SD) determined by direct arterial puncture were: systolic pressure, 114 to 194 mm Hg; diastolic pressure, 66 to 102 mm Hg; and mean pressure, 85 to 129 mm Hg. Ranges determined by use of oscillometry were: systolic, 110 to 190 mm Hg; diastolic, 35 to 107 mm Hg; and mean, 78 to 138 mm Hg. Ultrasonographic and oscillometric values did not accurately predict direct values, but mean values of systolic and mean pressures were similar among methods. Relationships were not detected between age or body weight and blood pressure. Significant differences in blood pressure were not detected between anxious and nonanxious dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Mean values of systolic, diastolic, and mean arterial blood pressure measured in nonsedated client-owned dogs, using invasive and noninvasive methods in a clinical setting, are comparable with those determined for acclimatized, trained, or sedated dogs. However, results of noninvasive methods may not accurately reflect direct values.  相似文献   

13.
Systemic arterial blood pressures were measured in 30 dogs with acute babesiosis, 10 each with mild uncomplicated, severe uncomplicated and complicated disease. Ten healthy dogs were used as controls. Hypotension was defined as more than 3 standard deviations below the control mean. Normal mean pressures (+/-SD) were: systolic arterial pressure 151 (+/-11) mm Hg, diastolic arterial pressure 89 (+/-8) mm Hg and mean arterial pressure 107 (+/-10) mm Hg. Hypotension was the most frequent abnormality, and increased strikingly in incidence as disease severity increased, with 5/10 dogs in the complicated group being hypotensive for systolic, diastolic and mean arterial pressures, compared with 2/10 in the severe uncomplicated group and 0/10 in the mild uncomplicated group. Systolic, diastolic and mean arterial pressures in the complicated group and severe uncomplicated group, and systolic pressure in the mild uncomplicated group, were significantly lower than in the controls. There were no significant relationships between arterial pressures and age, pulse rate, respiratory rate, temperature, mucous membrane colour or haematocrit. There was a significant negative correlation between arterial pressures and white cell and immature neutrophil counts. Arterial pressures differed significantly between dogs that were clinically collapsed and those that were not, but not between survivors and non-survivors. Pulse pressure (systolic-diastolic) was low in 7/10 complicated, 1/10 mild uncomplicated, and 1/10 severe uncomplicated cases, and differed significantly between the complicated and control groups. The high incidence of hypotension in clinically severe babesiosis has important implications for therapy.  相似文献   

14.
BACKGROUND: Systemic hypertension is likely underdiagnosed in veterinary medicine because systemic blood pressure is rarely measured. Systemic blood pressure can theoretically be estimated by echocardiography. According to the modified Bernoulli equation (PG = 4v(2)), mitral regurgitation (MR) velocity should approximate systolic left ventricular pressure (sLVP), and therefore systolic systemic blood pressure (sSBP) in the presence of a normal left atrial pressure (LAP) and the absence of aortic stenosis. The aim of this study was to evaluate the use of echocardiography to estimate sSBP by means of the Bernoulli equation. HYPOTHESIS: Systemic blood pressure can be estimated by echocardiography. ANIMAL: Seventeen dogs with mild MR. No dogs had aortic or subaortic stenosis, and all had MR with a clear continuous-wave Doppler signal and a left atrial to aorta ratio of < or = 1.6. METHODS: Five simultaneous, blinded continuous-wave measurements of maximum MR velocity (Vmax) and indirect sSBP measurements (by Park's Doppler) were obtained for each dog. Pressure gradient was calculated from Vmax by means of the Bernoulli equation, averaged, and added to an assumed LAP of 8 mm Hg to calculate sLVP. RESULTS: Calculated sLVP was significantly correlated with indirectly measured sSBP within a range of 121 to 218 mm Hg (P = .0002, r = .78). Mean +/- SD bias was 0.1 +/- 15.3 mm Hg with limits of agreement of -29.9 to 30.1 mm Hg. CONCLUSION: Despite the significant correlation, the wide limits of agreement between the methods hinder the clinical utility of echocardiographic estimation of blood pressure.  相似文献   

15.
OBJECTIVE: To evaluate the effects of metabolic acidosis and changes in ionized calcium (Ca2+) concentration on PaO2 in dogs. ANIMALS: 33 anesthetized dogs receiving assisted ventilation. PROCEDURE: Normal acid-base status was maintained in 8 dogs (group I), and metabolic acidosis was induced in 25 dogs. For 60 minutes, normocalcemia was maintained in group I and 10 other dogs (group II), and 10 dogs were allowed to become hypercalcemic (group III); hypocalcemia was then induced in groups I and II. Groups II and IV (5 dogs) were treated identically except that, at 90 minutes, the latter underwent parathyroidectomy. At intervals, variables including PaO2, Ca2+ concentration, arterial blood pH (pHa), and systolic blood pressure were assessed. RESULTS: In group II, PaO2 increased from baseline value (96 +/- 2 mm Hg) within 10 minutes (pHa, 7.33 +/- 0.001); at 60 minutes (pHa, 7.21 +/- 0.02), PaO2 was 108 +/- 2 mm Hg. For the same pHa decrease, the PaO2 increase was less in group III. In group I, hypocalcemia caused PaO2 to progressively increase (from 95 +/- 2 mm Hg to 104 +/- 3 mm Hg), which correlated (r = -0.66) significantly with a decrease in systolic blood pressure (from 156 +/- 9 mm Hg to 118 +/- 10 mm Hg). Parathyroidectomy did not alter PaO2 values. CONCLUSIONS AND CLINICAL RELEVANCE: Induction of hypocalcemia and metabolic acidosis each increased PaO2 in anesthetized dogs, whereas acidosis-induced hypercalcemia attenuated that increase. In anesthetized dogs, development of metabolic acidosis or hypocalcemia is likely to affect ventilatory control.  相似文献   

16.
Assessment of balloon pulmonary valvuloplasty in six dogs   总被引:1,自引:0,他引:1  
The effectiveness of balloon valvuloplasty was assessed, clinically and haemodynamically, in six dogs with moderate to severe pulmonic stenosis. The haemodynamic assessment was based on Doppler echocardiography, with colour flow mapping, in the conscious dog and by direct catheterisation in the anaesthetised dog, before and after balloon valve dilatation. Four of the six dogs were presented with exercise intolerance, of which two were in congestive heart failure. Balloon valvuloplasty resulted in improved exercise tolerance and resolution of congestive heart failure in these dogs. The average Doppler and catheter transvalvular pressure gradients were reduced to 43 per cent and 46 per cent of the preoperative gradient, respectively. The average pressure gradient obtained by catheter, in the anaesthetised dog, was 59 per cent of the pressure gradient obtained by spectral Doppler echocardiography in the conscious dog. Balloon valvuloplasty was considered successful in five out of the six dogs. Postoperative pulmonic regurgitation was not found to be a complication of balloon valvuloplasty.  相似文献   

17.
OBJECTIVE: To determine effects of the topically applied calcium-channel blocker flunarizine on intraocular pressure (IOP) in clinically normal dogs. ANIMALS: 20 dogs. PROCEDURES: Baseline diurnal IOPs were determined by use of a rebound tonometer on 2 consecutive days. Subsequently, 1 randomly chosen eye of each dog was treated topically twice daily for 5 days with 0.5% flunarizine. During this treatment period, diurnal IOPs were measured. In addition, pupillary diameter and mean arterial blood pressure (MAP) were evaluated. Serum flunarizine concentrations were measured on treatment day 5. Intraday fluctuation of IOP was analyzed by use of an ANOVA for repeated measures and a trend test. Changes in IOP from baseline values were assessed and compared with IOPs for the days of treatment. Values were also compared between treated and untreated eyes. RESULTS: A significant intraday fluctuation in baseline IOP was detected, which was highest in the morning (mean +/- SE, 15.8 +/- 0.63 mm Hg) and lowest at night (12.9 +/- 0.61 mm Hg). After 2 days of treatment, there was a significant decrease in IOP from baseline values in treated (0.93 +/- 0.35 mm Hg) and untreated (0.95 +/- 0.34 mm Hg) eyes. There was no significant treatment effect on pupillary diameter or MAP. Flunarizine was detected in serum samples of all dogs (mean +/- SD, 3.89 +/- 6.36 microg/L). CONCLUSIONS AND CLINICAL RELEVANCE: Topically applied flunarizine decreased IOP in dogs after 2 days of twice-daily application. This calcium-channel blocker could be effective in the treatment of dogs with glaucoma.  相似文献   

18.
BACKGROUND: In dogs, treatment of pulmonic valve stenosis (PS) with pulmonary balloon valvuloplasty (PBV) is a viable method to decrease the pressure gradient across the valve. However, to the authors' knowledge, the variables that influence the selection of the correct balloon size for the procedure have not been explored. Moreover, the lesions caused by the procedure have not been detailed. HYPOTHESIS: Variables that influence the measurement of the annulus could affect selection of the balloon size. We sought to determine the effects of treatment when the balloon-to-annulus ratio (BAR) was or > 1.3, but within the recommended range of 1.2-1.5, regardless of whether dilation was performed with single or double balloon technique. ANIMALS: Twenty-five Beagles with PS were studied. METHODS: Inter- and intra-observer variability, echocardiography versus angiocardiography, and systolic versus diastolic timing were evaluated for the BAR. Assessment of right ventricular (RV) pressure, Doppler gradient, stenotic valve area, and RV wall thickness were compared before and 1, 90, and 180 days after treatment. Postmortem examination of the heart was done. RESULTS: Significant correlations existed in measurement of the annulus; however, variation existed that would change balloon size. Improvement in the degree of PS was significant regardless of the BAR or single or double ballooning. In the most severely affected dogs, continued improvement was noted on day 90. Postmortem examination revealed tears in the commissures and the valve leaflets. CONCLUSIONS: Multiple factors influenced determination of the BAR and a range of 1.2-1.5 was effective without detrimental consequences. Dogs with severe PS had continued decrease in RV pressure 3 months after treatment.  相似文献   

19.
An open patch-graft technique for correction of pulmonic stenosis was performed in four dogs. A synthetic patch-graft was presutured to a partial-thickness incision in the right ventricular outflow tract and to the pulmonary artery along its cranial border. The pulmonary artery and right ventricle were incised during venous inflow occlusion, and dysplastic pulmonic valve leaflets were excised. The arteriotomy was closed by suturing the caudal margin of the incision to the patch-graft. The entire procedure was performed during mild hypothermia (30 degrees - 32 degrees C). The mean circulatory arrest time was 5.5 +/- 0.2 minutes. The mean systolic pressure gradient across the pulmonic valve before surgery was 121 +/- 29 mm Hg; after surgery it was 9 +/- 2 mm Hg.  相似文献   

20.
Background: English Bulldogs (EB) with pulmonic stenosis (PS) sometimes have an aberrant coronary artery (CA) type R2A encircling the pulmonary artery (PA). Balloon valvuloplasty (BV) is treatment of choice for severe PS, but is considered to be contraindicated in dogs with aberrant CA. Hypothesis: Conservative BV in EB with aberrant CA is safe and improves clinical signs and quality of life. Animals: Four client‐owned EB with severe PS were retrospectively reviewed/analysed. Methods: Retrospective study: Case records, echocardiography, BV, and follow‐up investigations of EB diagnosed with severe PS and treated with BV were reviewed. The ratios of PA to aortic (Ao) velocity time integral (VTI) were calculated to assess progression/improvement of PS. Results: An aberrant CA was confirmed on angiography in all EB. Conservative BV was performed, using a balloon of the size of the PA annulus or smaller (0.6–1 × PA annulus size). All dogs survived the procedure, but only a mild reduction in pressure gradient was achieved. There was an improvement in PA to Ao VTI in 3 of 4 dogs (P≤ .017), which were free of evidence of congestive heart failure (CHF) 5, 10, and 15 months after BV. One dog that had right‐sided CHF when BV was performed died due to progressive right‐sided CHF within 3 months. Conclusions: Conservative BV in EB might be safe and might improve quality and quantity of life.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号