1.
To counteract capacitive current and resume power system, the neutral point of 35 kV power system at the mountainous area is grounding through the arc winding widely. In fact, there is great difficult in selecting the arc winding to satisfy the requirement of system. In a 35 kV power system which neutral point is grounding through the arc winding, the capacitance current are measured in site when a single-phase is grounding. From the measure data, the imbalance of three-phase voltage whether the arc winding exist or not and the operating situation of arc winding are discussed, and bring forward an attentive problem about operation of arc winding and decrease of lightning outage rates.  相似文献   

2.
Research on Lightning Intruded Wave for 500 kV Substations   总被引:1,自引:0,他引:1  
The study on overvoltage for 500 kV substation caused by lightning intruded wave is presented. In this paper, we calculate by using electromagnetic transient program (EMTP) and combine substation with incoming lines ,so some influence factors can be considered such as impulse voltage second characteristic of insulator strings, lightning stroke point on the incoming lines and impulse grounding resistance of towers. The results show that the method is close to the practice and some factors of incoming lines are important to overvoltage.  相似文献   

3.
The paper presents a novel continuously adjustable Peterson coil. If it is used in the system of neutral point grounding through Peterson coil, not only the high price can be reduced and the complicated problems can be solved of which the high voltage inductance controlling systems, but also advantages of the system of neutral point grounding though Peterson coil can be shown. It is introduces that how adopts low voltage thyristors for continuing adjusting inductance of the Peterson coil of which the voltage level ranges from 6 kV to 66 kV. This paper discusses the formula of calculating the inductance variable ranges and the harmonic currents which presents stable harmonic current under the phase controlled mode also. The theory of the designing coil is verified by the Saber simulation and practicality experiment.  相似文献   

4.
This paper discuses the method with which the corrosion of the grounding grid can be diagnosed .A grounding grid can handled as a circuit network. With the application of circuit network graph theory and the fault diagnosis theory of analog circuit and optimization, the fault diagnosis equations can be set up. This equations is figured out by Matlab, and the corrosion status of the grounding grid can be deduced from the result.  相似文献   

5.
The unbalanced nature of 35 kV distribution system due to capacity values is difficult in neutral operation, which can not meet the demand of voltage balance in static state and arc distinct in fault. This paper proposes a new neutral operation as neutral insulation in static state and resonance grounding in fault , along with EMTP simulation acts. Simulation indicates that new neutral operation method can improve lightning withstand level and decrease trip-out rate of grids.  相似文献   

6.
The paper studies the theory about the corrosion as well as the broken point of the grounding grid in power plants and substations. By using sensitivity analysis, failure diagnosis equation is put up through rigorous theoretical analysis. Meanwhile the problem of morbid equation is solved by introducing lowest energy theory and technique of optimiation to diagnosis equation solution of grounding grid combined with definite constraint condition and linear or non-linear objective function, the fault diagnosis equation is discussed. The results of emulation calculation and analogous experiments verify the correctness,feasibility and practicality of the theory and method.  相似文献   

7.
The number of underdetermined equation, which is limited by the grounding down lines, reduces the grounding grid corrosion diagnostic precision. Based on the grounding grid fault diagnosis method and sensitivity analysis, the value of slip resistance change on the impact of the port resistance in several cases, such as small span, large span and edge, center and symmetrical cross line of the grounding grid, is analyzed. A new method which is used to select the node pairs to calculate the corrosion situation of grounding grid is presented. Based on this method, the simulation analysis and field test has been done. The experimental results show that this method could improve the accuracy and efficiency of grounding grid fault diagnosis.  相似文献   

8.
An equivalent model for hollowing-center grounding device is proposed, the hollowing-center grounding device resistance is calculated with the surface charge simulation method and the computer programme is programmed based on this model. The accuracy of the model and method is validated by experimentation.  相似文献   

9.
In order to find the most appropriate connection mode of 10 kV distribution network, a new approach is put forward ,in which the comprehensive weight method is applied to power system planning. At first, the main kinds of connection mode of 10 kV distribution network are introduced,then,basing on the information of subjective weights and objective weights, the performing process of the new approach is presented. It can choose the most appropriate connection mode of 10 kV distribution network sufficiently and can be calculated easily. At last, the validity and practicability of this new approach is testified with a sample.  相似文献   

10.
With theoretic analysis, lab experiment and engineering application, it is indicated that the SZJ grounding system is a new type grounding system which distinctly reduces the grounding impedance of grounding grids, especially of grounding grids in the zones with high-resistivity or grounding grids with scanty area. The design and calculation method for application of SZJ grounding system is also studied.  相似文献   

11.
Erosion Optimized Diagnosis of Brand Grounding Grid   总被引:1,自引:0,他引:1  
To find the corrosion of the grid ,large area cutting has been adopting in practice for a very long time. But this method is blind, difficult and influences the system operating. The erosion diagnosis method in the past is effective for the smaller grid. To the brand ones, it can not take effect. The method of separating the grounding grid into several parts and diagnosing step by step is discussed by lots of simulation about middle or brand grounding grid erosion diagnosis. This method makes the brand grounding grid erosion diagnosis quick and truly without power cut and digging large area, satisfies the demand in practice. Putting this optimized diagnosis method into practice , the result is good.  相似文献   

12.
Grounding grids are the guarantee of substation running safety. The fault of grounding grids is a threat to people and equipment in substations. A method to diagnose the fault of grounding grids based on magnetic field inverse problem. The inverse problem of magnetic field is established by injecting and extracting a low frequency current. The morbid of inverse problem is solved through regularization and Newton iteration method to obtain the distribution of the mesh currents. The approximate distribution of the magnetic field is calculated to diagnose the fault of the grounding grid. A 4×4 substation grounding grids is taken as an example. By comparison of the forward problem result, the error is under 3%, so the prposed method of inverse problem is verified. The selection of measurement point is discussed, and 40% of the number of meshes is accounted to approximate the real distribution of the magnetic field on the grounding grids.  相似文献   

13.
A new method is presented to calculate the non-uniform of current distribution on grounding electrode. Based on the equivalence of low frequency current field and static electric field, the electrode is simplified to he a line charge model with limited length. The charge distribution on the model is calculated by solving equilibrant equations, and the current distribution along the axis of electrode was got. The current density at the end of electrode can he several times of that in the middle, the non-uniformity get worse with the increasing of electrode length and numbers. This is what lead to several problems on grounding systems such as inefficiency, the partial overheat and the severe corrosion of electrode.  相似文献   

14.
To adapt to the continuous improvement of rural power consumption level in the new rural construction,in particular,with the continuous development of the rural economy,the actual operation of the rural power network has emerged as the high loss of electrical power which leads to a greater cost of the electricity,lower power supply reliability,the supply voltage and frequency do not satisfiy with requirements,etc.Through analysis of a typical rural power network,from the overall planning of the transmission to distribution equipments(such as lines,transformers and reactive-load compensation devices),the author proposes some specific measures such as reducing power loss and improving the voltage quality and reliability methods.Through calculation for lines power loss rate and percent of voltage pass,the results show that the methods proposed by the author are effective.The directions to the development trend of the rural power network is given.  相似文献   

15.
Based on the reactive surplus of Chongqing 220 kV main electric power network under low water and low load, and on state of higher system voltage, a thorough research is done on voltage and reactive power of the system power network by means of calculation,analysis and experiments. A main network calculating equivalence model of power network in Chongqing is constructed. And reactive power optimizing calculation is figured out on the Chongqing power network on condition that the loss minimum of the active power network is object function. Several optimizing compensatory schemes are put forward. Based on the calculation result and the analysis of all schemes, the most reasonable and feasible optimizing scheme could be achieved. Meanwhile, the feasibility that the system voltage could be adjusted when generator operating under excitation was demonstrated. According to the experience of under-excitation operation of the same type units , it decreases the system voltage, improves Chongqing power network running performance, and strengthens the coordination and stabilization of system.  相似文献   

16.
To prevent the duty cycle loss of full-bridge converter controlled by the phase-shifting method, a high frequency high voltage X-ray power supply is proposed. It combines full bridge LLC(FB-LLC) series resonant converter with bipolar single-phase symmetrical voltage multiplier. FB-LLC series resonant, high voltage transformer and bipolar single-phase symmetrical voltage multiplier are used in the main circuit. The LLC series resonant circuit and working conditions of soft switch are analyzed. The fundamental harmonic approximation model is established. The parameters of the main circuit are designed. The simulation results show that the output voltage adjusted continuously within 40~120 kV and without duty cycle loss. The X-ray power supply is proposed to achieve a quick rise and low ripple of output voltage. According to the simulation results, the proposed topology is correct and reliable.  相似文献   

17.
A heuristic research and fuzzy evaluation fault restoration algorithm for distribution network is proposed to quickly restore power supply for the regions where power supply is interrupted. The algorithm searches power supply paths by finding effective tie-switches and sectionalizing switches, and eliminates improper switch pair according to power flow calculation. During service restoration process, the problem is divided into self-healing restoration, whole-region restoration, sub-region restoration, load-transfer restoration and load shedding restoration. The algorithm takes switch operation times and customer priority into account, and consequently, obtains initial feasible schemes. Fuzzy technique is used to evaluate the schemes from minimal switch operation times, load transfer, feeder margin and maximal voltage drop. Weighted sum of four indices provides a good guideline for choosing the optimal scheme for restoration operation. Calculation results of a certain distribution network show that this algorithm is feasible.  相似文献   

18.
A hybrid power supply is composed by both a linear and a switching source connected in parallel and it can improve the dynamic response. But the hybrid power supply cant not effectively reject the perturbations in the power supply. A hybrid power supply based on one cycle control theory is proposed in order to improve the capability and the control precision. A switching source based on one cycle control is adopted in the hybrid power supply. The analysis results indicate that the hybrid power supply can effectively reject the perturbations in the power supply. And the analysis results also show that not only the control precision is improved, but also the control circuit is simple. The simulation resuits given verify the correctness and effectiveness of the proposed method.  相似文献   

19.
Generally there have a number of bad data in the electric load data and it affects the precision of load forecasting,so it is necessary for extracting the feature mode of days load data,then cleaning the load data before it is used to forecasting electric load or performing power system analysis.Inspired by soft clustering thought,a intelligent feature mode of days load data extracting method is proposed based on the mutual offset of fuzzy c-means clustering arithmetic and Kohonen self organization feature map neural network.With the merits of not only high extracting precision and convergent speed but also dynamic calculation capability,the method proposed can supply load forecasting or system analysis procedure with due data.Test results using actual data of Chengqu power supply bureau in Chongqing demonstrate the effectivity and feasibility of the method.  相似文献   

20.