首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVE: To report clinical outcome after use of an interlocking nail (veterinary interlocking nail [VIN]) for stabilization of diaphyseal fractures in dogs and cats. STUDY DESIGN: Retrospective study. Animals: Seventy-eight dogs and 43 cats with diaphyseal fractures of the femur (n = 96), tibia (n = 14), or humerus (n = 11). METHODS: Interlocking nails (4 mm diameter [n = 72], 6 mm [n = 25] or 8 mm [n = 24]), were used in static (n = 106) or dynamic (n = 15) fixation mode. Cerclage wires also were used in 63 (52%) cases. Data about the patient (species, breed, weight, age), characteristics of the fracture, and details of the surgery and perioperative complications were recorded. The surgeon evaluated functional outcome, and fracture healing was quantified 6 weeks (W6) and 3 months (M3) after surgery with a radiographic index. RESULTS: Twelve cases had been unsuccessfully treated by another technique. Of 106 comminuted fractures, 60 were classified as unstable. Only 112 animals were evaluated at W6; 86 (77%) healed without complication and had a functional outcome considered excellent (n = 80, 93%), good (n = 5, 4%), or fair (n = 1). Twenty-six complications were noted: 16 (14%) patients did not require additional surgery and had a good or excellent outcome, whereas 10 (8%) patients needed surgical intervention to CONCLUSIONS: VINs can be used to repair diaphyseal fractures of the femur, tibia, and humerus in dogs and cats provided the implants are appropriately sized for the fractured bone. The high healing rate (even with unstable fractures), associated with a functional outcome, and low complication rate support the use of VINs for these fracture types. However, a period of training and the application of basic principles are necessary to ensure successful results. CLINICAL RELEVANCE: VINs should be considered as alternative technique for management of selected diaphyseal fractures of the femur, tibia, and humerus in dogs and cats.  相似文献   

2.
The frequent need for removal of metallic implants after fracture healing, has stimulated research into biodegradable osteosynthesis materials. The ideal biodegradable implant should support the fracture during healing and would slowly lose strength as the bone became able to resist the distracting forces. Decades of research into biodegradable materials has given much information on biocompatibility, degradation rates and processability of resorbable polyglycolides and polylactides. This has aided the development of an ultra high strength self-reinforcing composite construction allowing the manufacture of implants for several purposes. This study tested the use of self-reinforced poly-1-lactic acid rods for the fixation of cancellous fractures and osteotomies in 20 fixations in dogs and cats. The operating technique, callus formation, healing pattern, and functional and radiological end result, were evaluated. Two fixations failed but the functional end result was judged to be excellent in all but one of the healed cases. There was no need for surgery to remove the implants.  相似文献   

3.
OBJECTIVES: To evaluate the use of ultrasonography (US) to detect bone healing in uncomplicated diaphyseal fractures of dogs and cats, and to compare these observations with detection of healing by radiography (RG). STUDY DESIGN: Clinical study. ANIMALS: Dogs (33) and cats (11). METHODS: RG and brightness mode US were used to follow uncomplicated secondary fracture healing. Fractures were examined at admission and then every 2-4 weeks until healed or implant removal. Temporal differences in definitive detection of healed fracture by imaging technique were examined by species, patient age, bone, and fracture type. RESULTS: US images obtained during uncomplicated secondary fracture healing were consistent with images of fracture healing described in humans. Mean time to US diagnosis of a healed fracture (mean 46 days) was significantly shorter than by RG (mean 66 days). Mean time until diagnosis of a healed fracture (US and RG) did not differ significantly between open and closed treatment. Patients 36 months (n=11), but there was no significant difference between the latter 2 groups. Diagnosis of a healed simple fracture by US was significantly quicker than for a comminuted fracture (P<.05), but no difference was noted when using RG. CONCLUSIONS: US can be used to evaluate secondary fracture healing in biologically treated fractures in dogs and cats. US permits detection of a healed fracture earlier than RG. CLINICAL RELEVANCE: Earlier diagnosis of a healed fracture by US can prevent unnecessarily long limb immobilization and allow earlier dynamization.  相似文献   

4.
The use of self-reinforced biodegradable devices made of polyglycolide in the cancellous bone and physeal fractures of dogs and cats was compared to the use of metallic devices and external fixations on similar fractures. The series consisted of 64 dogs and 22 cats divided into 6 comparable groups. The patients in the 2 groups fixed with biodegradable devices started to use their operated limbs earlier than in the other groups. The same 2 groups also healed clinically (showed no lameness) earlier than the other groups. Radiographically there was no statistical difference between the 6 groups.On the basis of this study it may be concluded that the fixation with self-reinforced biodegradable devices is as suitable for the fixation of cancellous bone and physeal fractures of dogs and cats as the fixation with metallic devices or external fixation. This biodegradable technique has additional benefits allowing the patients to feel less pain in their operated limbs and making secondary operations to remove the devices unnecessary.  相似文献   

5.
classification scheme for sacral fractures was based on a review of sacral fractures in 34 dogs and 17 cats. They were classified into five categories based on their radiographic appearance on standard lateral and ventrodorsal radiographs of the pelvis. Concomitant pelvic injuries were commonly observed: 32 per cent of dogs had a fracture of an ilium and 65 per cent of cats had unior bilateral sacroiliac subluxation. Neurological deficits were common where the fractures traversed the spinal canal or sacral foraminae. Comparison is made between sacral fractures in dogs and cats, and humans.  相似文献   

6.
Twenty-four simple or comminuted supracondylar and diaphyseal femoral fractures in cats, which had been treated by retrograde insertion of a new 3.5 mm titanium interlocking nail (IN) from the intercondylar notch, were evaluated between June 2000 and October 2004 at the Ecole Nationale Vétérinaire d'Alfort. Patient data (species, breed, weight, and age), fracture characteristics, details of the surgery, post-operative complications and radiographic follow-up were recorded. The mean body weight was 3.75 kg and the cats ranged in age between four and 66 months (mean 29 months). The IN had a diameter of 3.5 mm and a length of 100, 109 or 119 mm, and were all fixed in a static position (two screws in seven cats, three screws in 10 cats and four screws in seven cats). Cerclage wires were used in seven cats and an autogenous bone graft was used in two cats. Screw or nail breakage were not recorded. Nineteen fractures healed without any complications, three cats died during the post-operative period from unknown causes, and two cats showed delayed bone healing. Twenty cats were considered to have an excellent limb function at one month. One cat with a sciatic injury was non-weight bearing for several months. Radiographic signs of degenerative joint disease of the stifle joint were not observed except in the cat with the sciatic nerve injury. The results of this study suggest that this new 3.5 mm titanium IN can be introduced from the intercondylar notch and be used in static fixation mode to stabilize supracondylar and diaphyseal femoral fractures in cats.  相似文献   

7.
The aim of this study was to use radiography to assess and characterise naturally occurring keel bone fractures in laying hens and monitor live birds over several weeks to examine the healing process. Twenty-four Lohmann brown commercial laying hens with varying degrees of keel bone fracture were used in the study. Birds were radiographed regularly over six weeks and the radiographic features and changing appearance of keel bone fractures were evaluated. The radiographic characteristics of old and new fractures were categorised and indicated that 80 per cent of birds entering the study with new fractures had healed after 35 days and five birds had incurred new fractures irrespective of their original fracture status.  相似文献   

8.
A method of internal fracture fixation using rod-shaped biodegradable implants made of self-reinforced polyglycolic acid (PGA) is described. These biodegradable implants were employed in the fixation of fractures in a metaphysis and diaphysis. The fractures healed clinically and radiolo-gically in six weeks without complicatons. The patients started to use the operated limbs during the first postoperative week and lameness disappeared within six weeks. Biodegradable fixation devices will be a useful tool in the treatment of fractures in veterinary surgery.  相似文献   

9.
Medical records of 38 horses less than 1 year of age and diagnosed as having a fracture of the femoral diaphysis, metaphysis or distal physis were evaluated. Twenty-six foals had fractures of the femoral diaphysis or metaphysis with the most common fracture configuration being comminuted. Twelve foals had distal physeal fractures with the most common fracture configuration being a Salter-Harris type II. Twenty-one foals with fractures of the capital femoral physis, neck or greater trochanter during the same time period were excluded from this study. Surgical repair was attempted in 16 diaphyseal and 2 distal physeal fractures. Most of the diaphyseal fractures were repaired by placing plates on the lateral and cranial surfaces of the bone. Dynamic condylar screw plates or angle blade plates were used for increased bone purchase in 4 foals with short distal fragments. Five foals with distal physeal fractures were treated; 2 were surgically treated by placing an angle blade plate on the lateral cortex, and 3 foals with minimally displaced distal physeal fractures were managed with stall confinement. Eight of the 16 surgically repaired diaphyseal fractures healed. Fracture location and configuration was not a determinant of outcome, but the mean age of foals with successfully repaired diaphyseal fractures was 2 months compared with 4 months for the unsuccessful cases, indicating that the age and size of the foal was important. Long-term follow up revealed that 6 of the 8 successfully repaired diaphyseal fractures had no residual effects of the fracture observed during performance of the horse for its intended use. Only 1 of the 2 surgically repaired distal physeal fractures healed, but this horse was eventually killed because of unthriftiness related to a malabsorption syndrome. Some form of complication developed in 13 of the 18 surgically repaired fractures. Infection was the primary cause of failure. The greatest determinant associated with infection was the inability to control post-surgical seroma formation.  相似文献   

10.
Maxillofacial miniplates and screws were used for skeletal fixation in 15 dogs and 3 cats that sustained a variety of mandibular and maxillary fractures. These implants were used as neutralization or buttress fixation in 11 caudal (junction of the ramus with the mandibular body) and 2 rostral mandibular fractures, 4 maxillary fractures, and 2 zygomatic arch fractures. All but one of the fractures healed with appropriate occlusion and excellent function. In one case of a rostral mandibular fracture, soft tissue dehiscence occurred accompanied by a loss of the fixation and subsequent distraction of the bone fragments; reasonable function was obtained by performing a rostral mandibulectomy. Plate contouring and application of the miniplates along the appropriate biomechanical lines of stress was easily performed and permitted the biomechanical principles of tension band fixation to be applied in most cases. Miniplate fixation, either used alone or in combination with other fracture fixation techniques, achieved sufficiently rigid skeletal fixation to provide uncomplicated healing and good to excellent functional and cosmetic results in 14 dogs and 3 cats.  相似文献   

11.
OBJECTIVES: To test a non-glycosylated recombinant human bone morphogenetic protein-2 (ngly-rhBMP-2)/fibrin composite, which has been shown experimentally to enhance healing of bone defects in rodents, in a clinical case series of dogs and cats undergoing treatment for fracture non-unions and arthrodesis. METHODS: A ngly-rhBMP-2/fibrin composite was applied in 41 sites in 38 dogs and cats for which a cancellous bone autograft was indicated, replacing the graft. RESULTS: Bridging of the bone defect with functional bone healing was achieved in 90 per cent of the arthrodesis and fracture nonunions treated in this manner. CLINICAL SIGNIFICANCE: This prospective clinical study demonstrates the beneficial effects of ngly-rhBMP-2 in a specially designed fibrin matrix on the treatment of bone defects, and validates the use of this composite as an alternative to bone autografts in dogs and cats.  相似文献   

12.
Metacarpal fractures were more common than metatarsal fractures in this retrospective study of 37 dogs. Fractures of one metacarpal or metatarsal bone occurred In 24 per cent of the dogs, two metacarpal bones in 16 per cent, three metacarpal or metatarsal bones in 19 per cent, and four metacarpal or metatarsal bones in 41 per cent. Eighty-seven per cent of the dogs with fractures of four bones had fracture displacement or malalignment of at least one digit. Progressive fracture healing usually occurred Irrespective of stabilisation method. For malaligned fractures, however, external coaptation did not consistently improve alignment. Fracture alignment was consistently Improved by open reduction and internal fixation of acute fractures with bone plates. Fractures of four bones occurred most often In the distal metacarpus as opposed to the proximal metatarsus. Therefore, open reduction and internal fixation may be more commonly indicated for severe metacarpal fractures, because fracture displacement or axial1 malalignment was significantly associated with fractures of the mid or distal regions of the metacarpus or metatarsus (P=0.052).  相似文献   

13.
OBJECTIVE: To assess the suitability of the intramedullary interlocking nail to stabilise humeral diaphyseal fractures in dogs and cats. METHOD: This multi-centre study retrospectively examined medical records, between June 1994 and May 2001, of 19 dogs and one cat, in which a total of 21 humeral fractures were stabilised with intramedullary interlocking nails. RESULTS: Animals ranged in body-weight from 4 to 97 kg. Eighteen (86%) of the fractures were comminuted. Adjunctive stabilisation was used in twelve (57%) fractures and bone grafts in nine (43%) fractures. A rapid return of function was noted in the majority of animals, with 14 (67%) having good or excellent function within four days of surgery. In two fractures the repair collapsed when a single proximal transcortical screw was placed cranial to the tricipital line of the humerus. This suggests that if a single transcortical screw is placed proximally the screw should be distal or caudal to the tricipital line in order to engage sufficient cortical bone. Eighteen (86%) of the fractures healed when stabilised with intramedullary interlocking nails. Three fractures did not heal. One was in a dog where a pathological fracture was temporarily stabilised with an intramedullary interlocking nail, one in a dog that died of an abdominal crisis three weeks after surgery and one in a dog in which fracture stabilisation collapsed due to incorrect implant selection. CONCLUSION: Intramedullary interlocking nails are well suited to the stabilisation of humeral diaphyseal fractures in dogs and cats.  相似文献   

14.
A survey of bone fractures in the cat   总被引:1,自引:0,他引:1  
A survey of 108 bone fractures in the cat was made over a 1 year period in a city practice in south west England. Seventy-three per cent involved the pelvic limb. The three bones most commonly affected were femur (38%), pelvis/sacrum (22%) and mandible (16%). Forty-five cases were the result of road accidents and 75% of cats were 2 years old or less.
Treatment of femoral shaft fractures by intramedullary pinning gave good results. The majority of proximal epiphyseal separations and femoral neck fractures responded well to conservative treatment. 'Cage rest' was used successfully to treat severely comminuted femoral shaft fractures. All cases of pelvic fracture were treated conservatively (up to 3 weeks 'cage rest'). Separation of the mandibular symphysis and fracture of the horizontal ramus healed readily. Repair of tibial (10%) and humeral (5%) fractures was without complications.  相似文献   

15.
OBJECTIVE: To determine outcome for dogs and cats with diaphyseal fractures in which a plate-rod construct was used for fracture repair. DESIGN: Retrospective study. ANIMALS: 35 dogs and 12 cats. PROCEDURES: Medical records and radiographs were reviewed to obtain information concerning signalment, fracture severity, construct design, time to radiographic union, complications, and outcome. Clients were contacted by telephone to obtain information on complications, limb usage, and overall satisfaction with the procedure. RESULTS: 31 femoral, 9 humeral, and 7 tibial fractures were assessed. Thirteen fractures consisted of 2 fragments, 22 consisted of 3 to 5 fragments, and 12 consisted of > 5 fragments. Forty-six of 47 (98%) fractures reached union. Mean +/- SD times to radiographic union were 7.5 +/- 2.7 weeks for the dogs and 4.8 +/- 1.3 weeks for the cats. There were 4 short-term, minor complications and 15 long-term complications (2 major and 13 minor). Owners of 21 of 30 dogs (70%) and 9 of 12 cats reported that their animals had normal limb function. Twenty-six of 28 dog owners (93%) and 12 of 12 cat owners indicated that they were satisfied with results of the procedure. As surgery time increased, time to union also increased. Time to union for fractures with > 5 fragments was significantly shorter than time to union for fractures with < or = 5 fragments. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that plate-rod constructs can successfully be used for repair of diaphyseal fractures of a wide range of severity in dogs and cats.  相似文献   

16.
OBJECTIVES: To evaluate the specific cytological criteria of osteosarcomas in dogs. METHODS: Significant cytological characteristics of osteosarcoma and benign mesenchymal bone proliferations were determined from imprint smears of 25 dogs with osteosarcoma (group 1) and 20 dogs admitted for removal of surgical bone implants after uncomplicated healing of bone fractures (group 2). RESULTS: Mild to moderate cellular necrosis occurred frequently in patients with osteosarcoma. The cytoplasm of osteoblasts was pale blue to blue with a more pronounced basophilia in group 2. In 48 per cent of the patients in group 1, but none in group 2, osteoblasts showed a slight to moderate eosinophilic cytoplasmic granulation. In both groups, osteoblasts contained one red to pale blue nucleus with one or two grey-red to blue nucleoli in group 2. Forty-four per cent of animals in group 1 had osteoblasts with more than two nucleoli per nucleus. The median nuclear:cytoplasmic ratio was higher in group 1 (1:2.0) than in group 2 (1:3.5). Osteoblasts in group I were frequently seen to have a clumped chromatin pattern and showed significantly more criteria of malignancy (median six criteria per patient) than those in group 2 (median two criteria per patient). In group 1, mitoses of osteoblasts were detectable in 23 of 25 dogs, whereas only one dog in group 2 had evidence of mitotic osteoblasts. CLINICAL SIGNIFICANCE: Cytological criteria can be helpful in the diagnosis of canine osteosarcoma.  相似文献   

17.
OBJECTIVES: The aim of the here described case series was to develop and evaluate the minimally invasive percutaneous osteosynthesis for the plate fixation of tibial fractures in dogs and cats. METHODS: Six dogs and four cats with shaft fractures of the tibia were treated using minimally invasive percutaneous osteosynthesis. Follow-up radiographs four to six weeks after fracture fixation were evaluated for fracture healing. For the long-term follow-up (minimum 2.4 years), owners were contacted by phone to complete a questionnaire. RESULTS: All fractures healed without the need for a second procedure. Follow-up radiographs obtained after four to six weeks in seven cases showed advanced bony healing with callus formation and filling of the fracture gaps with calcified tissue in all seven. All the patients had a good to excellent long-term result with full limb function. The time needed for regaining full limb use was two to three months. CLINICAL SIGNIFICANCE: Minimally invasive percutaneous osteosynthesis seems to be a useful technique for the treatment of tibial shaft fractures in dogs and cats.  相似文献   

18.
Thirty dogs presented for open surgical repair of fractures were treated with prophylactic penicillin. Thirty other dogs with fractures were not given antibiotics. Each animal was monitored by clinical signs and deep aspiration culture, and followed for 6 months or until the fracture had healed and the implants had been removed.
No statistically significant difference was found in the number of clinical infections or positive bacterial cultures for each group. Differences in results between categories, such as type of injury, implants used, and surgeon, also were not statistically significant.  相似文献   

19.
Severely comminuted diaphyseal fractures in 11 dogs were repaired with standard bone plates that spanned a fracture gap filled with autogenous cancellous bone graft. Five dogs had closed injuries, 4 dogs had open fractures, and 2 dogs had infected nonunion fractures for which previous attempts at internal pin fixation had failed. A second autogenous cancellous bone graft was performed in 3 of the dogs during the healing period. The technique was successful in all dogs. The technique was considered a versatile and relatively simple alternative, compared with meticulous small fragment reconstruction and cortical bone allografts.  相似文献   

20.
The use of the AO (Arbeitgemeinschaft für Osteosynthesenfragen) veterinary T-plates (1.5/2 mm and 2.7/3.5 mm) for stabilisation of supracotyloid ilial fractures in 18 cats and five dogs was evaluated in a retrospective study. The distal fragment from the coxofemoral joint ranged from 0.5 cm to 1 cm with a mean distance of 0.85 cm. Twenty out of 23 (87%) ilial fractures healed in original alignment. Three out of 23 (13%) animals had two loosened screws of the distal fragment with fracture malunion and minor medial displacement of the acetabular fragment. Screw or plate breakage was not observed and the implants were not removed. The clinical result was 'excellent' for 18 animals (78%), 'good' for four animals (17%), and 'poor' for one animal (5%). The use of T-plates permits good correction of supracotylo?d fractures with minimal approach and minimizes post-operative complications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号