首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A modified version of the Conditt and Baumgardner gas chromatographic/mass spectroscopic (GC/MS) method for determination of daminozide in peanut butter and raw peanuts is described. Daminozide in the food product is hydrolyzed to unsymmetrical dimethylhydrazine (UDMH) by sodium hydroxide digestion. The generated UDMH is distilled from the food matrix and captured by reaction with salicylaldehyde in a condensation trap. Resulting high pH distillates generated by peanuts and peanut products are adjusted back to a pH of 5-6 through addition of glacial acetic acid. After thermal incubation and extraction into methylene chloride, salicylaldehyde dimethylhydrazone is separated from interferences by capillary GC and quantitated by MS using the selective ion monitoring (SIM) mode. Quantitation of daminozide is based on the ratio of the salicylaldehyde dimethylhydrazone molecular ion (m/z 164) to the molecular ion (m/z 153) of the internal standard, 4-nitroanisole. Confirmation of daminozide identity is determined by relative intensity of the m/z 164 ion to the m/z 120 (C7H4ON) ion. Improved m/z 164 ion intensity and reduction of neighboring interferences due to acetic acid treatment permitted a daminozide detection limit of 0.005 ppm in a 50 g sample and an associated 0.02 ppm limit of quantitation. This modification is specific for high protein samples that generate high pH distillates such as peanuts and peanut products and is not specifically intended for analysis of low protein samples.  相似文献   

2.
An improved method was developed for the quantitative determination of daminozide. This new method combines the alkaline hydrolysis and distillation steps of the PAM II method for daminozide with the derivatization, cleanup, and gas chromatographic determination steps of the Wright method for unsymmetrical dimethyl hydrazine (UDMH). The minimum detectable level is 0.05 ppm. Recoveries range from 85 to 110% when daminozide is added at 0.1 to 1.0 ppm, and are generally 40% at the 0.05 ppm level. A variety of domestic and imported products were analyzed by this improved method and daminozide was detected in 33 of the 98 samples analyzed. Levels detected ranged from a trace amount to 0.80 ppm. The identity of UDMH hydrazone was confirmed by mass spectrometry in many samples, thus confirming the presence of daminozide. Two samples containing daminozide were analyzed independently by a second laboratory and the findings were closely duplicated.  相似文献   

3.
A method using gas chromatography/chemical ionization mass spectrometry (GC/CIMS) for the determination of daminozide residues in apples has been developed. Daminozide was separated from the sample matrix by water extraction and cation exchange, converted to the methyl ester by treatment with HCl-methanol, and determined by GC/CIMS using succinonitrile as an internal standard. The detection level was 0.05 ppm. Recoveries were 92-104% from apples spiked at the 0.05-0.5 ppm levels. Of the 25 apple samples analyzed, only 2 were positive for daminozide (1.04 and 0.32 ppm).  相似文献   

4.
This paper reports an HPLC-UV method to determine daminozide residues in apple pulps adopting the recently introduced EU limit of 0.01 mg/kg for baby food preparation (Commission Directive 1999/39/CE). The method is based on alkaline hydrolysis of daminozide to N',N'-dimethylhydrazine (UDMH), which is recovered by distillation and subsequently derivatizated with salicyl aldehyde to salicyl aldehyde-N,N-dimethylhydrazone under strongly basic conditions. The resulting solution was cleaned up with Extrelut 20 NT and dichloromethane as eluent, then analyzed by HPLC with a C18 column and a mobile phase programmed from 50:50 AcCN/H(2)O to 100% AcCN. The salicyl aldehyde-N,N-dimethylhydrazone was selectively detected through two diagnostic UV absorption maxima at 295 and 325 nm, which have strong molar absorbivities. Recoveries of daminozide at 0.01 mg/kg were above 80%. The limits of detection (LODs) of salicyl aldehyde-N,N-dimethylhydrazone expressed as daminozide concentration were 100 pg/microL at 295 nm and 150 pg/microL at 325 nm, and the limits of quantitation (LOQs) of daminozide were 0.0013 mg/kg at 295 nm and 0.0022 mg/kg at 325 nm.  相似文献   

5.
An MS-based method, combining reversed-phase capillary liquid chromatography (capillary LC) with quadrupole time-of-flight tandem mass spectrometry (nano-ESI Q-TOF MS/MS), was developed with the aim of identifying a set of peptides that can function as markers for peanut allergens. Emphasis was given to the identification of the three major peanut allergens Ara h 1, Ara h 2, and Ara h 3, because these proteins are considered to represent >30% of the total protein content of peanut and are directly relevant for the allergenic potential of this food. The analytical data obtained were used to perform databank searching in combination with de novo sequencing and led to the identification of a multitude of sequence tags for all three peanut allergens. Food processing such as roasting of peanuts is known to affect the stability of proteins and was shown to influence the detection of allergen sequence tags. The analysis of raw and roasted peanuts allowed the identification of five peanut-specific sequence tags that can function as markers of the specific allergenic proteins. For Ara h 1, two peptide markers were proposed, namely, VLEENAGGEQEER (m/z 786.88, charge 2+) and DLAFPGSGEQVEK (m/z 688.85, charge 2+), whereas for Ara h 2 only one peptide, RQQWELQGDR (m/z 439.23, charge 3+), was found to satisfy the required conditions. For Ara h 3, the two specific peptides, SPDIYNPQAGSLK (m/z 695.35, charge 2+) and SQSENFEYVAFK (m/z 724.84, charge 2+), were selected. Other peptides have been proposed as indicative for food processing.  相似文献   

6.
A method using gas chromatography/electron ionization-mass spectrometry (GC/EI-MS) in the selected ion monitoring (SIM) mode was developed for the analysis of fatty acids as methyl esters (FAMEs) in order to determine their percentage contribution to the fatty acid profile in food. In the GC/EI-MS-SIM mode, saturated fatty acids were determined with m/z 87, monoenoic fatty acids were determined with m/z 74, and polyenoic fatty acids were determined via the sum of m/z 79 and m/z 81. The ratios of these fragment ions and the GC retention data provided additional information for tentative structural assignments. The 28 FAME standards tested provided similar results for the novel GC/EI-MS-SIM method and GC/EI-MS in the full scan mode, both of which were slightly worse than GC/flame ionization detection (FID). Analysis of sunflower oil, suet, and cod liver oil verified that both major and minor fatty acids (20-60% and down to 0.001% contribution to the fatty acid pattern) were determined with sufficient quality that justifies application of the GC/EI-MS-SIM method for the analysis of food samples. Furthermore, the method was approximately 20- or approximately 10-fold more sensitive than GC/EI-MS in the full scan mode or GC/FID, respectively. The method is suited for both quantitative purposes and fatty acid identification in samples where only low amounts of lipids are available.  相似文献   

7.
The present paper describes a liquid chromatographic (LC) method for purification of crude swine tissue extracts before gas chromatographic/mass spectrometric (GC/MS) quantitation and confirmation of sulfamethazine at low ppb levels. Fractions corresponding to sulfamethazine were collected, evaporated to dryness, N-methylated with diazomethane, concentrated, and analyzed by GC/MS. A mass spectrometer was set to selected ion monitoring (SIM) mode. Ions 233, 227, 228, and 92 m/z were detected. Ratio 227/233 m/z (sulfamethazine/internal standard, [phenyl 13C6] sulfamethazine) was used for quantitation, while ratios 228/227 and 92/227 m/z, respectively, were used for confirmation. Quantitation in spiked blank muscle tissue was tested from 100 to 1 ppb and found acceptable at all concentrations studied; coefficients of variations ranged from 4.9 to 14.4%. Similar results were obtained for liver tissue from 5 to 20 ppb; coefficients of variation ranged from 1.2 to 9.1%.  相似文献   

8.
A simple, sensitive, and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining urinary creatinine was developed and used to evaluate 24 h urine samples collected during an exposure study. Urine (1 microL) was diluted with methanol and then directly applied to LC-MS/MS. Under electrospray ionization (ESI) conditions, the transition molecules of creatinine and creatinine- d3 were observed at m/ z 114 > 44 and m/ z 117 > 47, respectively. The retention time of creatinine was 0.59 min. The linear range was 1-2000 ng/mL, with a detection limit in urine of 1 ng/mL. LC-MS/MS and colorimetric end-point methods were significantly associated ( R2 = 0.8785, p < 0.0001). The LC-MS/MS method to determine creatinine in 24 h urine samples had shorter retention times, was more sensitive, reliable, reproducible, simple, selective, and used a smaller sample size than other LC-MS/MS or commercial methods.  相似文献   

9.
The method describes a rapid and accurate procedure for the analysis of ethyl carbamate in wines. The separation of the ethyl carbamate (EC), the target analyte, from alcohol and the sample matrix is a challenge to many analytical chemists. After alcohol removal from the sample, EC was extracted and concentrated by solid-phase extraction. For analysis of EC, large-volume injection on a programmable temperature vaporization (PTV) inlet was used followed by multidimensional gas chromatography/mass spectrometry (MDGC/MS) using electron-impact ionization (EI). For quantitation, the ratio of ions produced during EI at m/z 62 (EC) and 64 (isotopically labeled EC) was monitored. The use of solid-phase extraction and MDGC/MS removes the majority of the matrix interference encountered in other methods. A linear dynamic range was established from 0.387 to 1160 ng/mL, with a limit of detection at 0.1 ng/mL and limit of quantitation at 1 ng/mL.  相似文献   

10.
In support of the efforts to combat smuggling, as well as illegal sale and distribution of cigarettes, an analytical approach for the characterization of tobacco has been proposed and evaluated. It involves aqueous extraction of the filler tobaccos followed by direct analysis of the extracts by electrospray ionization-ion trap mass spectrometry (ESI-ITMS) in the negative mode. Typically, the deprotonated ions, [M - H](-), of organic acids (malic, citric, caffeic, quinic acid) and polyphenols (chlorogenic acid, rutin, scopoletin) were detected. MS/MS spectra of the ion at m/z 191, which is the [M - H](-) of quinic acid, citric acid, and scopoletin, and a fragment ion of chlorogenic acid were acquired. Significant differences in the MS and MS/MS spectra were observed between counterfeit samples and the corresponding authentic brand name cigarettes. Analysis of 25 commercial cigarettes showed that straight Virginia blends were readily distinguished from the blended products containing different tobacco types (Virginia, burley, and Oriental). The former exhibited consistently higher relative abundances of m/z 353 (chlorogenic acid) to m/z 133 (malic acid) in the MS spectra (0.9-1.2 vs 0.4-0.6) and higher intensity ratios of m/z 176 (scopoletin) to m/z 173 (0.4-0.8 vs 0.1-0.3) and of m/z 127 (quinic acid) to m/z 173 (0.7-1.0 vs 0.3-0.5) in the MS/MS spectra. Evidence is presented to demonstrate that the spectral differences were related not only to the tobacco type (Virginia, burley and Oriental) but also to the tobacco part (stem, lamina) used in the manufacture of the cigarettes.  相似文献   

11.
A method is described for the determination of pentachlorophenol (PCP) in gelatin. The method employs acid and heat to hydrolyze the gelatin matrix, a base partition and wash for separation and cleanup, and a reacidification and extraction with hexane for direct determination of PCP, without preparation of a derivative, using gas chromatography (GC) with a 1% SP- 124ODA liquid phase and a 63Ni electron capture detector. Recoveries averaged 106% for fortifications between 0.02 and 1.0 ppm. The limit of quantitation is 20 ppb. The limit of detection is 4-6 ppb. The method, which has undergone a successful intralaboratory trial, is simple and rapid, and requires only general laboratory reagents and equipment. GC of the acetate derivative of PCP is used for confirmation of identity.  相似文献   

12.
A new method is described to determine trace quantities of N-nitrosodiethanolamine (NDElA) in aqueous diethanolamine (DElA) formulations and in oil solutions of dinoseb. A formate anion-exchange column is used in series with a cation-exchange column if there is DElA in the formulation. The eluate is then passed through a Clin Elut column. Depending on the concentration of NDElA in the sample, a packed silica-gel column is used to purify the extract further. This extract is analyzed on a liquid chromatograph coupled with a thermal energy analyzer (LC/TEA), using a mixture of methanol-hexane-methylene chloride containing 0.1% acetic acid (8 + 56 + 35) as the mobile phase. This solvent system gives good separation of NDElA from trace quantities of dinoseb remaining in the extract. The NDElA is also converted to the trimethylsilyl derivative and analyzed by gas chromatograph coupled with a mass spectrometer (GC/MS). Analyses of 11 commercial samples of dinoseb diethanolamine salt showed NDElA levels of 116-2409 ppm expressed relative to the weight of dinoseb. In contrast, analyses of 2 samples of organic solutions of technical dinoseb showed NDElA levels to be nondetectable and 0.3 ppm, respectively. Limit of detection by LC/TEA is 6.5 ng (0.5 ppm), and by GC/MS it is 0.02 ng (0.15 ppm). Recoveries from samples spiked at 0.514-1664 ppm range from 92.2 to 105.2%.  相似文献   

13.
Determination of sulfite in food by flow injection analysis   总被引:3,自引:0,他引:3  
A method is described for the determination of sulfite levels in food products by flow injection analysis (FIA). The method is based on the decolorization of malachite green by SO2, which is isolated from the flowing sample stream by means of a gas diffusion cell. The FIA method has a detection limit in food sample extracts of 0.1 ppm SO2 (3 times peak height of blank), which corresponds to 1-10 ppm SO2 in a food product, depending on the extraction procedure used. At the 5 ppm SO2 level in a food extract, the precision of replicate injections is +/- 1-2%. The method was tested on a variety of both sulfite-treated and untreated food products and the results compared favorably with those obtained by the Monier-Williams, colorimetric (pararosaniline), and enzymatic (sulfite oxidase) methods. The average differences from the FIA results were 19, 11, and 12%, respectively, for those samples (n = 12) above 50 ppm SO2. At lower levels the results were somewhat more erratic due to inaccuracies of the various methods at low concentrations.  相似文献   

14.
采用固相萃取(SPE)为样品前处理方法,建立了超高效液相色谱-串联四极杆质谱联用(UPLC-MS/MS)检测土壤中咪唑乙烟酸的残留分析方法。土壤样品经0.1 mol.L-1的氯化铵与氨水缓冲液(pH=10)超声提取、C18SPE柱净化后,应用超高效液相色谱串联四级杆质谱仪多离子反应监测(MRM)定量检测,分别以碎片离子m/z 290〉176和m/z 290〉245进行外标法定量。结果表明,在0.01~0.5mg.kg-1添加水平范围内咪唑乙烟酸的平均添加回收率在83.47%~101.70%之间;相对标准偏差在4.15%~5.28%之间;咪唑乙烟酸的定量检出限(LOQ)为0.075μg.kg-1。该方法灵敏度高,操作简单,定量准确,可用于土壤中咪唑乙烟酸的残留分析。  相似文献   

15.
A gas chromatographic-mass spectrometric method for the determination of S-methyl-L-cysteine sulfoxide (1), S-propyl-L-cysteine sulfoxide (2), and S-propenyl-L-cysteine sulfoxide (3), specific marker compounds in the genus Allium, is described. The target amino acids were converted to the tert-butyldimethylsilyl derivatives. The products were silylated on the amino and carboxyl groups and on an additional oxygen atom and were separated on a nonpolar capillary column. That incorporation of three tert-butyldimethylsilyl groups had occurred was verified by mass spectrometry, which gave an m/z 302 fragment as base peak (amino acid side chain eliminated ion) and m/z 436 (1), 464 (2), or 462 (3) as major peaks (tert-butyl function eliminated ion), by electron impact ionization. The detection limits for 1 and 2 under selected ion monitoring at m/z 436 (1) and m/z 464 (2), respectively, were determined to be 0.3 and 1.8 ng per injection. To clean up the analytes from the solvent extract of onion, as a representative food material, onion, the sample solution was subjected to combined solid phase extraction. The eluate from a Sep-Pak C(18) cartridge was applied to a Bond Elut SCX cartridge (H(+) form), followed by washing with 0.1 M hydrochloric acid and elution with 0.5 M ammonia. From a simulated matrix solution containing 5% sucrose, 1 and 2 were extracted quantitatively, and the detection yield was approximately 75%. The contents of 1, 2, and 3 in commercial onion were estimated to be 0.3, 3.1, and 3.0 mg, respectively, per gram of fresh weight.  相似文献   

16.
Enzymatic digestion of total protein along with liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to confirm the presence of a major peanut allergen in food. Several peptides obtained from the enzymatic digestion of the most abundant peanut allergen, Ara h 1, were identified as specific peptide biomarkers for peanut protein. Using ice cream as a model food matrix, a method was developed for the detection of the allergen peptide biomarkers. A key component of the method was the use of molecular mass cutoff filters to enrich the Ara h 1 in the protein extracts. By applying the method to ice cream samples containing various levels of peanut protein, levels as low as 10 mg/kg of Ara h 1 could routinely be detected. This method provides an unambiguous means of confirming the presence of the peanut allergen, Ara h 1, in foods and can easily be modified to detect other food allergens.  相似文献   

17.
Detection of peptides from the peanut allergen Ara h 1 by liquid chromatography-mass spectrometry (LC-MS) was used to identify and estimate total peanut protein levels in dark chocolate. A comparison of enzymatic digestion subsequent to and following extraction of Ara h 1 from the food matrix revealed better limits of detection (LOD) for the pre-extraction digestion (20 ppm) than for the postextraction digestion (50 ppm). Evaluation of LC-MS instruments and scan modes showed the LOD could be further reduced to 10 ppm via a triple-quadrupole and multiple-reaction monitoring. Improvements in extraction techniques combined with an increase in the amount of chocolate extracted (1 g) improved the LOD to 2 ppm of peanut protein. This method provides an unambiguous means of confirming the presence of the peanut protein in foods using peptide markers from a major allergen, Ara h 1, and can easily be modified to detect other food allergens.  相似文献   

18.
This paper reports on the applicability of gas chromatography coupled to ion-trap tandem mass spectrometry (GC/ITMS/MS) for the analysis of polychlorinated dibenzo- p-dioxins (PCDDs), dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) in food. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for food analysis. Good precision (RSD=5-18% for PCDD/Fs and 6-14% for dl-PCBs) and low limits of detection for PCDD/Fs (0.1-0.93 pg/g of fat) and dl-PCBs (0.1-0.89 pg/g of fat) were obtained. A comparative study of the congener-specific determination using both GC/ITMS/MS and GC-high resolution mass spectrometry (GC/HRMS) was performed by analyzing several matrices such as milk, fish oil, chicken, pork, fish, eggs, and a chicken compound feed, at low pg/g levels. The results using GC/ITMS/MS were in good agreement with those obtained by GC/HRMS. Consequently, GC/ITMS/MS is proposed for the analysis of PCDD/Fs and dl-PCBs in food and feed samples.  相似文献   

19.
An indirect competitive ELISA was developed allowing the detection of hidden peanut protein residues down to 2 ppm (micorgrams per gram) in various foods. The high-titer, peanut-specific polyclonal antiserum used recognized potentially allergenic proteins in both native and roasted peanuts. In the absence of a food matrix, extractable protein from roasted peanuts was detected at 104 +/- 13%. From various food items, peanut protein at > or =13 ppm was recovered between 84 and 126%, and at 2 ppm of peanut protein recovery was 143 +/- 6%. Intra- and interassay precision was <15%. In 5 of 17 commercial food products without declaration of peanut components, between 2 and 18 ppm of peanut protein was detected. This is the first assay based on commercially available reactants that allows the reliable determination of trace amounts of hidden peanut allergens in a variety of complex food matrices.  相似文献   

20.
为分析罗氏海盘车性腺的单甘酯组成,本研究对单甘酯的衍生方法和色谱条件进行优化,并对单甘酯硅烷化衍生物的断裂规律和质谱特征进行分析,同时对罗氏海盘车性腺的单甘酯组成进行分析测定。结果表明,三甲基硅烷化法对单甘酯具有理想的衍生效果,且通过弱极性毛细管柱HP-5MS(30 m×0.25 mm×0.25 μm)对单甘酯硅烷化衍生物取得了理想的色谱分离效果。根据断裂规律和质谱特征,1-单甘酯硅烷化衍生物的特征离子为m/z 73、m/z 205、[M-103]+(基峰离子)和[M-15]+;2-单甘酯硅烷化衍生物的特征离子为m/z 73(基峰离子)、m/z 129、m/z 218、[M+H-162]+和[M-15]+。单甘酯硅烷化衍生物的色谱保留时间具有一定的规律性,其中2-单甘酯衍生物先于1-单甘酯衍生物出峰。同时,从罗氏海盘车中共鉴定出8种单甘酯,以1-单软脂酸甘油酯(1-C16:0-MG)和1-单硬脂酸甘油酯(1-C18:0-MG)等1-单甘酯为主,而2-单甘酯含量较低。本研究结果为单甘酯的衍生、色谱分析和质谱鉴定提供了一定的理论参考。  相似文献   