首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
There is little information in veterinary literature regarding the diagnostic accuracy of aspirate cytology for the diagnosis of canine osteosarcoma (OSA). The authors compared the diagnostic accuracy of a novel method of cytologic collection, termed core aspirate cytology (CA), with fine needle aspiration (FNA) and histopathology in 27 dogs with lytic and/or proliferative bone lesions. Alkaline phosphatase (ALP) staining was performed to confirm the diagnosis of OSA cytologically. OSA was accurately diagnosed in 85% and 95% of FNA and CA, respectively. ALP staining was 100% sensitive for the diagnosis of OSA. CA using a bone marrow biopsy needle allowed for penetration of cortical bone and aspirate cytology with a larger bore needle than FNA; however, there was no significant difference in diagnostic accuracy between techniques. Aspirate cytology with ALP staining was a safe, accurate, and minimally invasive diagnostic test for the evaluation of suspected OSA lesions in dogs.  相似文献   

2.
Gregory B.  DANIEL  DVM  MS  James S.  Avenell  VMT  Karen  Young  BS  Gary L.  Mason  DVM  Kevin A.  Hahn  DVM  PhD 《Veterinary radiology & ultrasound》1996,37(2):146-149
This report describes the detection of subclinical soft tissue metastasis of an appendicular osteosarcoma in a dog using bone scintigraphy. A 7-year-old spayed female Rottweiler was presented with a biopsy confirmed diagnosis of osteosarcoma. Initial radiographs revealed an aggressive bone lesion of the left distal radius. At presentation, there was no clinical or radiographic evidence of metastasis; however, a nuclear bone scan showed the primary bone lesion of the distal left radius and numerous soft tissue lesions consistent with diffuse soft tissue metastases. A left foreleg amputation was performed and cisplatin chemotherapy was given post-operatively. A second bone scan performed one month following initial presentation showed progression in size and number of soft tissue masses. Many of the lesions had become apparent on physical exam and survey radiographs. Excisional biopsy was performed on one of the soft tissue masses and a diagnosis of metastatic osteosarcoma was made. The dog was euthanized 2 months after initial presentation at the owners request due to deterioration of the animals physical condition.  相似文献   

3.
In humans, free-hand computed tomography (CT)-guided biopsy is an accurate method to obtain a tissue sample. There are only a few reports of this technique in veterinary medicine. In the present study, 21 dogs and two cats underwent a free-hand CT-guided tissue-core biopsy (17 animals) or fine-needle aspiration (six animals) of a bone lesion. Two out of 17 tissue-core samples were also cultured. All 17 tissue-core biopsy samples were diagnostic (accuracy of 100%). Five out of six aspirates were diagnostic (accuracy of 83.3%). The overall accuracy was 95.7%. In one aspirate, cytologic quality was insufficient containing only blood. No major complications were encountered. Fourteen neoplastic, two infectious and six benign lesions were diagnosed. CT examination after intravenous contrast medium added useful information to avoid large vessels and to biopsy-viable tissue. Free-hand CT-guided tissue-core biopsy and aspiration appears to be a safe and very accurate procedure for use in the diagnosis of bone-associated diseases in small animals.  相似文献   

4.
A percutaneous biopsy technique for the study of endochondral bone formation in the dog was developed. With the dogs under general anesthesia or sedated with a combination of a tranquilizer and a local anesthetic, biopsy specimens were obtained from the proximal growth plate of the humerus with the use of a Jamshidi bone biopsy needle. Biopsy specimens were structurally intact, and contained epiphysis, growth plate, and metaphysis. The procedure proved to be a simple, safe technique, which caused minimal discomfort for the patient and did not affect the growth of the proximal end of the humerus, even after multiple biopsies.  相似文献   

5.
Our objective was to evaluate possible differences in the number of glomeruli and length of renal biopsies collected in canine subjects by two different types of biopsy needles: a semiautomatic 18-gauge Trucut and an automated 18-gauge Jamshidi modified (Biopince). One hundred biopsy samples obtained from dogs of different ages and gender affected by different nephropathies were evaluated retrospectively. All animals were biopsied using one of the two different needles. Biopsies were performed under ultrasound guidance and evaluated by a single pathologist. Statistical analysis was performed to evaluate possible differences in the number of glomeruli and length of renal biopsies collected comparisons were determined between subgroups of dogs with or without the identification of renal interstitial infiltrates and/or fibrosis. Neither the mean difference of the number of glomeruli nor the length of tissue sample collected with the different needles was significantly different. Likewise, the average biopsy length did not differ in dogs with or without renal interstitial infiltrate in animals biopsied with either biopsy needle. Both the Biopince and the Trucut devices provide diagnostically adequate biopsy renal specimens using ultrasound-guidance.  相似文献   

6.
Fine needle aspiration biopsy is a fast and inexpensive technique well tolerated by animals. Its efficacy for the diagnosis of malignancy and determination of cellular origin was investigated for 97 malignant tumors and five benign lesions in 83 dogs and 19 cats. Histological examination of the lesions was performed in each case. Malignancy was detected by cytology in 69% of the malignant tumors. The cellular origin of the lesion was determined in 74% of the cases. Confirmation of malignancy and determination of cellular origin permitted an early diagnosis and prognosis. Since fine needle aspiration biopsy and cytology cannot definitely rule out malignancy, a surgical biopsy and histopathology should be done when malignancy is suspected clinically and not confirmed cytologically. Specimens of good quality, adequate collaboration between the cytologist and clinicians, and sufficient knowledge of pathology and cytology are basic requirements for obtaining good results with fine needle aspiration biopsy and cytology.  相似文献   

7.
This report describes computed tomography (CT)-guided stereotactic brain biopsy using the Kopf stereotactic system, a commercially available patient restraint system which does not require additional modification for use in small animals. The accuracy of biopsy needle placement was determined by injecting dilute iohexol into cadaver brains and comparing the three-dimensional coordinates of the desired target location to the actual needle tract observed on postcontrast CT images. Overall mean error in needle placement in a dorsoventral trajectory was 0.9 +/- 0.9 mm (n = 80 injections) for dogs and 1.0 +/- 1.1 mm (n = 30 injections) for cats. The overall mean error in needle placement via an oblique trajectory in five dogs was 1.7 +/- 1.6 mm (n = 12 injections). These results suggest that this system can be used to successfully place a biopsy needle into the brain to obtain biopsies from small lesions.  相似文献   

8.
Medical records and computed tomography (CT) images were reviewed retrospectively for 30 animals (27 dogs, two cats, one cougar) in which CT-guided intrathoracic fine-needle aspirates (FNA) (12), core biopsies (10) or both (8) were performed. Sample interpretation was listed as diagnostic or nondiagnostic and nonneoplasia or neoplasia. Diagnostic results were inconclusive in 35% FNA and 17% biopsies. FNA and biopsy interpretations were in agreement in seven patients, one nonneoplasia, and six neoplasia. A clinical diagnosis was made in 65% FNA and 83% biopsies. When 18 patients with confirmed diagnoses were used, overall accuracy for diagnosis was 92% for FNA and biopsy and the sensitivity for neoplasia was 91% using fine needle aspirate and 80% using biopsy. Complications seen on CT images were noted in 43% of patients, four pneumothorax, five pulmonary hemorrhage, and four with both. No clinical manifestations were noted and treatment was not necessary. Significant correlation was noted between complications and penetration of aerated lung, but not with lesion location, type of disease, method of sampling, width of mass and depth of aerated lung penetrated. CT-guided sampling is relatively safe and useful in the diagnosis of intra-thoracic lesions, especially neoplasia. FNA samples are nondiagnostic more often than biopsy samples. Sub-clinical pneumothorax and hemorrhage are common when aerated lung is penetrated.  相似文献   

9.
The purpose of this study was to describe the ultrasonographic appearance of non-cardiac diseases of the small animal thorax. Ultrasound images from a total of 75 animals (26 cats and 49 dogs) were compared to cytologic, histopathologic, and necropsy findings. Clinical diagnoses included neoplasia of the mediastinum, pleura, or lungs (43); idiopathic mediastinal cyst (3); diaphragmatic or peritoneopericardial hernia (4); lung lobe torsion (1); pulmonary eosinophilic infiltrates (1); and idiopathic, chylous, congestive heart failure, or lymphangiectasia associated pleural effusion (14). In the remaining 9 patients, a definitive diagnosis was not obtained. Ultrasound-guided fine needle aspirate was performed in 56 patients; 1 of these also had an ultrasound-guided tissue core biopsy. Of the fine needle aspirates, 51 (91%) were diagnostic. Ultrasound examination, particularly when accompanied by guided tissue sampling, can be a valuable tool in the diagnosis of non-cardiac intrathoracic lesions.  相似文献   

10.
In this study, 25 dogs each with a histopathologically diagnosed appendicular or axial osteosarcoma were prospectively and consecutively examined by methylene diphosphate nuclear scintigraphy. Scannings that revealed scintigraphically enhanced focal increased activity via bone uptake of the 99mTc methylene diphosphate radionuclide at sites other than the primary tumor site were compared with scintigrams obtained from dogs without osteosarcoma. Secondary scintigraphic sites were evaluated by survey radiography and, if possible, by histologic examination (biopsy or necropsy specimens). On the basis of our findings, scintigraphy seems to be more efficient than physical examination and radiographic bone survey for the diagnosis of multicentric, metachronous, or metastatic canine osteosarcoma.  相似文献   

11.
OBJECTIVES: To determine the ability to obtain diagnostic cytology samples from appendicular bone lesions using ultrasound-guided needle aspirations. Secondary objectives were to compare cytological evaluations with histopathological results and to determine the utility of staining malignant mesenchymal cells for the presence of alkaline phosphatase. METHODS: Aspirations from 36 aggressive appendicular bone lesions with histological diagnoses were included in the study. Ultrasound was used to guide the needle to the medullary cavity or the adjacent soft tissue mass. The smears stained with Wright-Giemsa and nitroblue tetrazolium chloride/5-bromo-4-chloro-3-indoyl phosphate toluidine salt (NBT/BCIP) were examined. RESULTS: A diagnostic sample was obtained in 32 of the 36 cases. Of the 32 diagnostic samples, cytology indicated sarcoma, with a sensitivity of 97 per cent (confidence interval: 83 to 100 per cent) and a specificity of 100 per cent (confidence interval: 16 to 100 per cent). When a diagnosis of sarcoma was made on cytology, alkaline phosphatase staining indicated osteosarcoma, with a sensitivity of 100 per cent (confidence interval: 87 to 100 per cent). CLINICAL SIGNIFICANCE: The results of this study indicate that ultrasound-guided needle aspiration of aggressive bone lesions is a viable technique for identifying malignant mesenchymal cells and for diagnosing sarcomas. It is cost-effective and minimally invasive. Furthermore, identifying alkaline-phosphatase-negative malignant mesenchymal cells from a bone aspiration may rule out osteosarcoma, whereas alkaline-phosphatase-positive malignant mesenchymal cells are suggestive of osteosarcoma.  相似文献   

12.
The purpose of this study was to develop a percutaneous lung biopsy technique to be used on steers in a commercial feedlot setting. Thirty-four crossbred steer and heifer calves from a commercial feedlot in southern Alberta were used in this study. The calves originated from the auction market and all were chronically affected with bovine respiratory disease (BRD). A technique was developed to obtain a lung sample from the right cranioventral lung lobe, intercostal space (ICS) 2, using a manual or an automatic biopsy instrument with a 14- or 12-gauge (ga) biopsy needle. Overall, lung parenchyma was successfully harvested in 55.9% of experimental animals and in 55.0% of lung biopsy trials. Compared with postmortem diagnosis, the biopsy resulted in the same pathologic diagnosis for 75% of biopsy samples when evaluated using standardized criteria by the same veterinary pathologist. The success rate was 61.5% and 42.9% in a hospital or field setting, respectively. With an automatic instrument, lung was recovered from 57.9% and 37.5% of samples obtained using a 12- or 14-ga biopsy needle, respectively. One experimental animal or 2.9% of the total had fatal complications from the procedure. In a commercial feedlot setting, the procedure took 20 min for each animal. Percutaneous lung biopsy of the right cranioventral lung lobe may be a viable technique when used on feedlot steers affected with chronic pneumonia. These findings suggest that using an automatic instrument with either a 14- or 12-ga biopsy needle may yield lung samples that are suitable for histopathological evaluation. However, this technique needs to be further evaluated in a field setting.  相似文献   

13.
CASE HISTORY: A 4-year-old female Labrador Retriever was diagnosed with an osteolytic lesion of the right distal radius. CLINICAL FINDINGS: Radiographs indicated a well-circumscribed radiolucent area 18 x 15 x 8 mm, centred on the distal radial physeal scar. DIAGNOSIS: Histopathology, performed via Jamshidi needle biopsy and following surgical curettage, was inconclusive but suggested either an aneurysmal bone cyst or fibrous dysplasia. CLINICAL RELEVANCE: A novel processed cancellous bovine bone xenograft was used in conjunction with autogenous cancellous bone (at a ratio of approximately 4:1) to fill the curetted defect. There were no observed complications associated with the use of this new biomaterial. Osteointegration of the bone graft was followed using conventional radiographs and peripheral quantitative computed tomography (pQCT) for 10 months post-operatively. Radiographically, the osteolytic lesion modelled to resemble metaphyseal trabeculation. The cross-sectional area and the average bone density of the grafted lesion determined using pQCT data increased over time, suggesting healthy osteoconduction and native bone production.  相似文献   

14.
Extraskeletal osteosarcoma is a very rare tumor in humans and animals including rats. This paper describes a case of extraskeletal osteosarcoma observed in the glandular stomach of an aged female Fischer 344 rat. Grossly, a whitish solid mass was observed at the greater curvature of the glandular stomach. Histologically, the tumor consisted of both atypical polygonal and pleomorphic spindle-shaped cells, with pleomorphic nuclei, and it contained variable amounts of osteoids and small clumps of mature bone tissue. In addition, mitotic figures were frequently observed. Neither invasion of the muscle layer or vessels in the stomach nor metastasis to distant organs was detected. There were no skeletal tumors in the body. Immunohistochemically, the tumor cells were positive for osteocalcin, osteonectin, vimentin and S-100 protein. Judging from these results, the present tumor was diagnosed as extraskeletal osteosarcoma. This is the first report of spontaneous extraskeletal osteosarcoma arising from the stomach in a rat.  相似文献   

15.
The objective of this work was to compare the accuracy of radiographs and magnetic resonance imaging (MRI) for estimating appendicular osteosarcoma margins. The accuracy of computed tomography (CT) and bone scintigraphy was also assessed when these studies were available. Eight dogs with appendicular osteosarcoma underwent radiographic and MRI of affected limbs. In addition, bone scintigraphy was performed in six dogs and CT examination was performed in five dogs. Two observers jointly measured tumor length on all imaging studies. Correlative gross and histologic evaluation of all affected limbs was performed to determine tumor extent as measured from the nearest articular surface. Results from imaging studies were compared to gross and microscopic morphometry findings to determine the accuracy of each modality for determining tumor boundaries. MRI images were accurate with a mean overestimation of actual tumor length of 3 +/- 13%. T1-weighted non-contrast images were superior in identifying intramedullary tumor margins in most instances whereas contrast-enhanced images provided supplemental information in two dogs. Lateromedial and craniocaudal radiographs overestimated tumor length by 17 +/- 28% and 4 +/- 26%, respectively. Scintigraphy and CT overestimated tumor margins by 14 +/- 28% and 27 +/- 36%, respectively. MRI appears to be an accurate diagnostic imaging modality in determining intramedullary osteosarcoma boundaries. MRI should be considered as part of a pre-operative assessment of appendicular osteosarcoma, particularly when a limb-sparing procedure is contemplated.  相似文献   

16.
The ultrasonographic appearance of clinically undifferentiated neck masses for which a definitive diagnosis was eventually obtained in nineteen dogs and one cat is presented in this report. Multiple lesions were seen ultrasonographically in 4 dogs and no cervical abnormalities were seen in 2 dogs resulting in 22 lesions in 20 annuals. Of 7 benign lesions, there were 2 patients with reactive lymph nodes from a regional inflammatory process, and 1 patient each with primary pyogranulomatous lymphadenitis, arteriovenous malformation, foreign body granuloma, cellulitis, and hematoma. Of 15 malignant lesions, 7 were thyroid carcinomas, 3 were lymphomas with submandibular and cervical lymph node enlargement, 3 were lymph node enlargements associated with regional metastasis of malignant tumors, one was a leiomyosarcoma and one was a carotid body tumor. One dog with a diffuse soft tissue swelling of the ventral cervical region had only slight asymmetry of the thyroid lobes on ultrasound examination and no abnormalities of the neck at post mortem. A second dog examined with ultrasound 4 months after surgical removal of a carotid body tumor had no evidence of tumor recurrence. Ultrasonographic examination provided information regarding the character of the lesions, the tissue or organ of origin, and invasion into other anatomic structures. Ultrasound examination in conjunction with fine needle or tissue biopsy provided a definitive diagnosis in those animals in which biopsies were performed.  相似文献   

17.
OBJECTIVE: To compare morphologic diagnoses determined from needle biopsy specimens obtained from the livers of dogs and cats with morphologic diagnoses determined from wedge biopsy specimens. DESIGN: Prospective study. ANIMALS: 124 dogs and cats. PROCEDURE: 2 needle biopsy specimens were obtained from each animal; wedge biopsy specimens were obtained from the same liver lobe during laparotomy or postmortem examination. Histologic features were scored independently by 3 individuals; a morphologic diagnosis was rendered after histologic features were scored. Cases were included only if at least 2 of the 3 examiners agreed on the morphologic diagnosis; the definitive diagnosis was considered to be the morphologic diagnosis rendered for the wedge biopsy specimen. Physical characteristics (length, width, surface area, degree of fragmentation, and number of portal triads for needle biopsy specimens and surface area for wedge biopsy specimens) were determined. RESULTS: Definitive diagnoses included hepatic necrosis (n = 10), cholangitis-cholangiohepatitis (13), chronic hepatitis-cirrhosis (12), canine vacuolar hepatopathy (11), portosystemic vascular anomaly-microvascular dysplasia (17), neoplasia (10), miscellaneous hepatic disorders (18), and no hepatic disease (33). For individual examiners, the morphologic diagnosis assigned to needle biopsy specimens agreed with the morphologic diagnosis assigned to wedge biopsy specimens for 56 and 67% of the specimens. All 3 examiners agreed on the morphologic diagnosis assigned to needle and wedge biopsy specimens for 44 and 65% of the specimens, respectively. Morphologic diagnoses assigned to needle biopsy specimens concurred with the definitive diagnosis for 59 of 124 (48%) animals. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that needle biopsy specimens of the liver from dogs and cats must be interpreted with caution.  相似文献   

18.
Clinicians and pathologists are sporadically asked by owners whether the taking of tumour biopsies may affect the behaviour of the tumour, including its potential to metastasise. Unfortunately, systematic studies on this subject are unavailable in veterinary medicine, and the aim of this study was to estimate the risk of adverse effects of biopsy taking on tumour progression in animals. A systematic review of veterinary and human case reports and clinical studies as well as experimental animal models of biopsy-induced tumour metastasis was undertaken. There were only two veterinary case reports of needle tract metastases (NTM) following the taking of needle biopsies from urogenital and pulmonary tumours. Seventeen experimental studies found a high incidence of NTM but only a rat osteosarcoma and a hamster squamous carcinoma model showed an increased incidence of distant or regional metastases after incision or excision biopsy. In human medicine, the occurrence of NTM has been reported after the taking of biopsies from mesotheliomas (15%), melanomas (11%) and gall bladder tumours (11%), liver metastases of colon carcinomas (4%) and mammary carcinomas (4%) but an incidence of only <1% for all other tumours. Circulating tumour cells increased immediately after the taking of biopsies from human squamous cell, prostate, breast and hepatocellular carcinomas. Although no increased risk of biopsy-induced distant metastasis has been reported for any type of tumour, this is inconclusive due to a lack of non-biopsied control groups in human studies. Reports of biopsy-induced metastasis in animal tumours indicate that the taking of transcutaneous biopsies from urogenital tumours may be associated with a risk of NTM. However, there is no evidence of a general increase in risk of distant metastases in any tumour type in people or animals. The overall risk therefore appears to be negligible when compared to the valuable information obtained from biopsies in veterinary practice.  相似文献   

19.
20.
OBJECTIVE: To determine the accuracy of cytologic diagnosis, compared with histologic diagnosis, in determination of disease in ultrasound-guided fine-needle aspirates of splenic lesions. DESIGN: Retrospective study. SAMPLE POPULATION: Splenic specimens from 29 dogs and 3 cats. PROCEDURES: Records were searched for dogs and cats that had undergone ultrasound-guided splenic aspiration. Criteria for inclusion were ultrasonographic identification of splenic lesions and cytologic and histologic evaluation of tissue from the same lesion. Cytologic samples were obtained by fine-needle aspiration, and histologic specimens were obtained via surgical biopsy, ultrasound-guided biopsy, or necropsy. RESULTS: Cytologic diagnoses corresponded with histologic diagnoses in 19 of 31 (61.3%) cases and differed in 5 of 31(16.1%) cases, and 1 aspirate was inadequate for evaluation. In 7 of 31 (22.6%) cases, histologic evaluation of tissue architecture was required to distinguish between reactive and neoplastic conditions. On the basis of histologic diagnosis in 14 animals with nonneoplastic conditions, the cytologic diagnosis was correct in 11 cases, not definitive in 2 cases, and incorrect in 1 case. In 17 animals with malignant neoplastic diseases, the cytologic diagnosis was correct in 8 cases, not definitive but consistent with possible neoplasia in 5 cases, and incorrect in 4 cases. Multiple similar-appearing nodules were significantly associated with malignancy, whereas single lesions were more often benign. CONCLUSIONS AND CLINICAL RELEVANCE: Ultrasound-guided aspiration of splenic lesions is a minimally invasive tool for obtaining specimens for cytologic evaluation. Although cytologic diagnoses often reflect histologic results, if missampling or incomplete sampling occurs or tissue architecture is required to distinguish between reactive and neoplastic conditions, accurate diagnosis with fine-needle aspiration may not be possible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号