首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: Platelets are of great importance in the pathogenesis of endotoxemia. Although thrombocytopenia is used as a diagnostic sign of endotoxemia, changes in values for platelet indices (plateletcrit [PCT], mean platelet volume [MPV], and platelet size distribution width [PDW]) in response to endotoxin are still unknown. OBJECTIVE: The aim of this study was to evaluate platelet count and its relations with platelet indices in a canine model of endotoxemia. Methods: Twenty dogs were divided into 2 groups of 10 each, and treated intravenously with Escherichia coli endotoxin (1 mg/kg) or vehicle. Venous blood samples were collected before treatment (0 hour) and 0.5, 1, 2, 4, 6, 8, 12, and 24 hours after treatment. Platelet counts and indices were determined on a CELL-DYN hematology analyzer. RESULTS: The platelet count and PCT decreased by a mean of 73% and 93%, respectively (P<.001), at 0.5 hour, and remained 70% and 85% lower than baseline values (P<.001) for 24 hours after endotoxin injection. MPV and PDW increased by a mean of 28% and 45%, respectively (P<.01), at 0.5 hour, and remained increased by 7% and 16% over baseline values for 24 hours (P<.01-.001). Platelet count correlated positively with PCT (P<.001), but correlated negatively with MPV (P<.001) and PDW (P<.01). CONCLUSIONS: Changes in platelet count and its association with platelet indices may reflect changes in platelet production and reactivity. Platelet indices have potential value in the diagnosis and monitoring of dogs and humans with endotoxemia.  相似文献   

2.
矮小型褐壳蛋鸡与普通蛋鸡血液生理生化指标比较分析   总被引:1,自引:0,他引:1  
试验测定了40周龄矮小型褐壳蛋鸡血液生理指标、血清生化指标,以同日龄白来航作为对照组,每品种公母各9只。结果表明,品种之间差异显著性(P0.05)的项目主要有PLT、MPV、PDW%、MCH、MCHC、PCT、AST、ALT、TP和TG,同时,矮小型褐壳蛋鸡公鸡的MCV、RDW%、TG显著低于白来航公鸡(P0.05),矮小型褐壳蛋鸡公鸡的MCHC、PLT、PCT、AST、ALT和TP显著高于白来航公鸡(P0.05),矮小型褐壳蛋鸡母鸡的PLT、MPV和PDW%显著高于白来航母鸡(P0.05)。  相似文献   

3.
BACKGROUND: Platelet aggregates are a common artifact in canine blood. Aggregates may affect the accuracy of platelet counts, with important consequences for patient care. OBJECTIVES: The purpose of this study was to determine if platelet counts in dogs were more accurate if blood was collected into citrate instead of EDTA as an anticoagulant. METHODS: Blood was collected from 50 dogs with neoplasia admitted to the oncology service at Cornell University. EDTA and citrate Vacutainer tubes were filled with blood in random order. Platelet counts and parameters (mean platelet volume [MPV], platelet distribution width [PDW], mean platelet component concentration [MPC], platelet component distribution width [PCDW], and automated platelet clump count [APCC]) were determined using an optical-based hematology analyzer (ADVIA 120). Blood smears from each anticoagulated sample were scored visually for platelet aggregates. RESULTS: The median platelet count was significantly lower (median decrease, 27 x 10(9)/L) in citrate-anticoagulated blood compared with EDTA-anticoagulated blood. This was attributed to platelet activation and aggregation: significantly more aggregates were seen in smears of citrate- than of EDTA-anticoagulated blood. Aggregates were typically small and not detected by the analyzer. Also, the MPV and MPC (or density) were significantly higher (median increase, 3 fL) and lower (median decrease, 33 g/L) in citrate-anticoagulated samples, respectively. CONCLUSIONS: Platelets aggregate, likely from activation, when blood from dogs with neoplasia is anticoagulated with citrate for hematology testing, resulting in lower platelet counts. Citrate also yields inaccurate results for MPV and MPC, likely because of inadequate sphering of platelets. Thus, we recommend that citrate not be used as an anticoagulant when accurate platelet counts are desired in dogs.  相似文献   

4.
Few studies have examined platelet alterations in dogs with chronic enteropathy. Our aim was to investigate platelet count (PLT), mean platelet volume (MPV), and platelet-to-lymphocyte ratio (PLR) in dogs diagnosed with immunosuppressant-responsive enteropathy (IRE). In this retrospective study of 41 dogs, data regarding signalment, canine chronic enteropathy clinical activity index (CCECAI), endoscopic and histopathological scores, PLT, MPV, PLR, total serum protein concentrations, albumin, and iron were collected. Clinical response and relapse were assessed with the evaluation of CCECAI over time. One month after starting therapy, dogs with >25% CCECAI reduction were considered responders. During a three-month CCECAI evaluation as part of a twelve-month follow-up, a CCECAI >3 together with a ≥2 unit increase in responder dogs was considered a relapse. PLT and PLR displayed significant negative correlation with MPV. MPV was positively correlated with total protein and albumin levels and negatively correlated with CCECAI. Three dogs were classified as non-responders, and 14 relapsed within 12 months. No differences were observed in PLT, MPV, or PLR between responding/non-responding and relapsing/non-relapsing groups. PLT, MPV, and PLR correlated with total protein, albumin, and CCECAI, confirming PLT as a potential marker, and suggesting MPV as a new marker of clinical efficacy against canine IRE.  相似文献   

5.
BACKGROUND: Hereditary canine stomatocytosis has been described in purebred Alaskan Malamutes, Drentse Patrijshonds, and Miniature Schnauzers. In humans, hereditary stomatocytosis is a heterogeneous group of congenital disorders characterized by the presence of stomatocytes in blood, increased osmotic fragility, and frequently, hemolytic anemia. OBJECTIVE: Our objective was to describe hematologic findings and RBC characteristics in 7 closely related Standard Schnauzers with stomatocytosis. METHODS: The following parameters were measured using an automated analyzer: HCT, RBC, hemoglobin (Hb) concentration, MCV, MCH, MCHC, red cell distribution width (RDW), WBC, platelet count, mean platelet volume (MPV), thrombocrit (PCT), and platelet distribution width (PDW). Differential leukocyte count, platelet estimate, reticulocyte count, and the percentage of stomatocytes in blood films were microscopically evaluated. An osmotic fragility test of RBCs and measurement of intracellular Na+, K+, and 2,3-diphosphoglycerate (2,3-DPG) concentrations were also performed. RESULTS: The affected dogs had macrocytosis (80.0 +/- 4.2 fL, reference interval 60-76 fL), decreased MCHC (29.3 +/- 0.8 g/dL, reference interval 32-39 g/dL), slightly increased RDW (17.3 +/- 0.4%, reference interval 12-16%), and an increased reticulocyte count (1.55 +/- 0.77%, reference interval <1%). The percentage of stomatocytes in blood films varied from 0.6 to 18.9% of all RBCs. Erythrocyte osmotic fragility and intracellular Na+ (138.1 +/- 3.2 mmol/L; controls 99 +/- 6.1 mmol/L), K+ (8.1 +/- 0.8 mmol/L; controls 6.1 +/- 0.5 mmol/L), and 2,3-DPG (21.9 +/- 2.0 micromol/g Hb; controls: 14.6 +/- 3.3 micromol/g Hb) concentrations were increased in dogs with stomatocytosis. CONCLUSIONS: Hematologic findings and the metabolic defects in RBCs in these Standard Schnauzers were consistent with a diagnosis of stomatocytosis. Parentage analysis suggests that stomatocytosis in Standard Schnauzers may have a hereditary component.  相似文献   

6.
The analytic precision of an automated blood analyzer, the Technicon H*1(R), was evaluated utilizing blood samples collected from 20 piglets at 1 and 14 days of age. The effect of storing the blood samples at 4 degrees C for 24 and 48 hours also was determined. Blood samples were analyzed twice on the first day and once on each of the subsequent tow days. Within-sample coefficient of variation was approximately 1% for hemoglobin concentration, erythrocyte count, hematocrit, mean cell volume, erythrocyte distribution width and hemoglobin distribution width (HDW); and approximately 5% for total leukocyte (WBC), neutrophils and lymphocyte counts. Mean HDW and automated differential WBC counts changed during storage to a degree that could be of clinical importance. Manual determination of differential WBC counts were compared with those obtained from the automated analyzer. Results correlated well for neutrophils (r=0.92 in 1-day-old and r=0.93 in 14-day-old piglets, P<0.001) and lymphocytes (r=0.85 in 1-day-old and r=0.93 in 14-day-old piglets, P<0.001). Other WBC values were too low to compare reasonably.  相似文献   

7.
BACKGROUND: Age-related changes in hematologic values are known to occur in many species. Few published studies include repeated measurements of hematologic parameters in calves during the first months of life. OBJECTIVE: The aim of the present study was to monitor hematologic values by sequential measurements from birth to 6 months of age in 15 healthy calves of the Norwegian Red breed, and compare the results to reference intervals for adult, lactating dairy cows. METHODS: Fifteen clinically healthy calves were sampled every week during the first 5 weeks of life and every month thereafter until 6 months of age. Hematologic values were measured using the ADVIA 120 hematology system. Reference intervals were determined for 75 healthy adult cows of the same breed. RESULTS: Compared with adult reference intervals, the MCV was lower and the RBC count was higher in calves throughout the investigation period. Hemoglobin concentration stayed largely within the adult reference interval. Mean MCHC was lower than adult values for 5 weeks, then increased and reached adult values by weeks 10-12. The mean lymphocyte count for calves reached adult reference values at weeks 6-8, and the mean monocyte count increased steadily until weeks 14-16. For most leukocytes, interindividual variation was larger during the first 5-8 weeks of life. The mean platelet count for calves was higher than the adult reference interval until weeks 19-21 of age. CONCLUSIONS: Age-specific reference intervals for calves from birth to 6 month of age are needed for RBC count, MCV, MCHC, red cell distribution width, and platelet and lymphocyte counts.  相似文献   

8.
In the presented study we evaluated the hematological changes in samples of blood obtained from 248 dogs naturally infected with large Babesia. The evaluation included red blood cell count, hemoglobin concentration, hematocrit, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), leucocyte counts, thrombocyte counts, mean platelet volume (MPV), morphology of erythrocytes and leucogram. The most common disorders in affected dogs were thrombocytopenia and anisocytosis. The count of erythrocytes below reference values was detected in 26.2% of dogs and 31.4% of affected animals presented hematocrit below the reference values. Hemoglobin concentration below the reference values was noted in 29% of dogs, an increase of MCHC above normal values was detected in 21% of examinated dogs and MCV below normal values was recognized in 2% of dogs. 60.5% of dogs presented anisocytosis, 25% poikilocytosis, 23.8% polychromasia, 19.7% hypochromia and 4.4% erythroblastosis. Thrombocytopenia was detected in 99.5% of dogs, but only 15.3% of examined animals showed increase of MPV, which suggests a response of the bone marrow. 36.3% of dogs had neutropenia, and 21.8% presented a left shift, 14.9% had the lymphocytosis and 7.2% lymphopenia.  相似文献   

9.
The aims of the study were to evaluate the effect of iron-dextran injection given on the first, third or fourth day after birth on haematology in piglets. An advanced automated blood analyser; Technicon H*1, which performs a complete blood cell count and leukocyte differential counts was used to analyse the blood. Six litters of Norwegian Landrace x Yorkshire piglets were included in the study. The day after birth (day 1), half of the piglets in each litter (split litters) were injected subcutaneously with 180 mg iron as iron-dextran (1.5 ml Idofer). The untreated piglets from two of the litters were injected with the same amount of iron-dextran on day 3, and those from the remaining four litters on day 4. The piglets were weighed and blood samples collected on days 1, 3 or 4, 7, 14 and 21. Erythropoiesis, but not leukocyte count, responded to injection on day 1 compared with injection on the third or fourth day. The difference between groups in haematological parameters was greatest on day 7. The two groups of piglets treated on day 1 had a haemoglobin concentration (Hb) +/-SD of 92 g litre-1(+/-9) and 94 g litre-1(+/-9), and the piglets treated on day 3 had a Hb of 81 g litre-1(+/-7) and the one treated on day 4 had a Hb of 78 g litre-1(+/-7) on day 7. On days 14 and 21 there were no differences between groups. This study indicates that some piglets were anaemic and responded to subcutaneous iron injection on day 1.  相似文献   

10.
试验测定20、40、60周龄矮小型褐壳蛋鸡血液生理指标、血清生化指标,每一周龄公、母鸡各9只,样本量为54只。将数据进行t检验及多重比较分析,结果表明,在此3个时间点上,指标RBC、HGB、MPV、PDW、LYMF%、TP和CHO呈现上升趋势,指标HCT、MCV、RDW%、WBC、LYMF值是先下降后上升,而MCH、MCHC、PCT、PLT、MID、MID%、GRAN、GRAN%、AST、ALB、TG、GLU和ALT值是先上升后下降。同时,不同周龄鸡之间在血液生理生化指标上表现出不同项目差异显著(P0.05)。20、40及60周龄矮小型褐壳蛋鸡雌、雄间均存在显著差异(P0.05)的血液生理生化指标有RBC、HCT、HGB、WBC、LYMF和AST,这表明矮小型褐壳蛋鸡的生理和生化指标随周龄不同,在雌、雄之间的差异随之发生变化。  相似文献   

11.
OBJECTIVE: To evaluate platelet surface-associated P-selectin, mean platelet component concentration (MPC), mean platelet component distribution width (MPCDW), mean platelet volume (MPV), and platelet distribution width (PDW) for detection of activated platelets in dogs with septic and nonseptic inflammatory disease. ANIMALS: 20 healthy dogs and 20 dogs with septic and nonseptic inflammatory disease. Procedures-Platelet surface-associated P-selectin (expressed as the median fluorescence intensity [MFI] of the platelet population), MPC, MPCDW, MPV, and PDW were determined in 20 healthy adult dogs, and reference ranges were calculated. These parameters were also determined in 11 dogs with nonseptic and 9 dogs with septic inflammatory disease and evaluated to determine which parameters were useful for detection of activated platelets. Results-12 dogs with inflammatory disease had P-selectin greater than the upper limit of the reference range, whereas 16 dogs with inflammatory disease had MPC lower than the lower limit of the reference range. All dogs in which P-selectin was greater than the upper limit of the reference range had MPC lower than the lower limit of the reference range. The correlation coefficient for P-selectin and MPC was 0.62. Differences in the MPCDW, MPV, and PDW in most dogs with inflammatory disease (compared with healthy dogs) were found; however, the correlation coefficients for P-selectin and MPCDW, MPV, and PDW were low. CONCLUSIONS AND CLINICAL RELEVANCE: Platelet surface-associated P-selectin and MPC appeared to be useful to detect activated platelets in most dogs with septic and nonseptic inflammatory disease.  相似文献   

12.
Ovine babesiosis, caused by Babesia ovis, is of major economic importance in Turkey. The changes in the blood profile of infected animals are informative about the course of infection. The aim of the present study was to evaluate the hematological and biochemical changes in the pre- and post-treatment periods of the natural B. ovis infections. The presence of the parasites was confirmed by microscopy and polymerase chain reaction (PCR) analysis. On the basis of the clinical and laboratory findings, the infections were categorized into different groups according to the degree of anemia and the level of parasitemia. All infected sheep were treated with imidocarb dipropionate (IMDP). The blood pictures in the pre- and post-treatment periods were compared.Pancytopenia occurred in animals with severe anemia and very high parasitemia, and bicytopenia in the other groups. The platelet count (PLT), plateletcrit (PCT) and mean platelet volume (MPV) returned to the normal ranges after treatment, except those in the group with severe anemia. In the biochemical profile, B. ovis infection caused an increase in blood urea nitrogen and total bilirubin, and these parameters returned to normal levels after treatment.The indirect fluorescein antibody test (IFAT) results showed that 38.1% of the cases raised specific antibodies during the period of infection, with titers ranging from 1/160 to 1/640. All of 45 animals re-examined after treatment were seropositive, with high titers that rose up to 1/5120.  相似文献   

13.
Peritoneal fluid was analysed from 17 foals, aged 13 to 134 days with a mean age of 68 days. Cytologically, the peritoneal fluid was characterised by a mean total cell count of 0.45 x 10(9)/litre (range 0.06 to 1.42 x 10(9)/litre), rare eosinophils, rare cytophagia and variable percentages of neutrophils and mononuclear cells. These data indicate that peritoneal fluid nucleated cell counts over 1.50 x 10(9)/litre in the foal should be interpreted as elevated. Biochemical evaluation revealed a mean biuret protein level of 12 g/litre, mean refractive index protein level of 16 g/litre and urea nitrogen concentration of 1.96 mmol/litre. There was no correlation between the foals' white blood cell and peritoneal fluid nucleated cell counts. Results of this study indicate that adult horse reference values for evaluation of peritoneal fluid are of questionable validity for foals. Diagnostically, the most important observation was that maximum peritoneal fluid nucleated cell counts in healthy foals were much lower than reported maximal reference values for adult horses (1.5 x 10(9)/litre versus 5.0 x 10(9)/litre or 10.0 x 10(9)/litre).  相似文献   

14.
Background: The laser‐based Sysmex XT‐2000iV hematology analyzer is increasingly used in veterinary clinical pathology laboratories, and instrument‐specific reference intervals for dogs are not available. Objective: The purpose of this study was to establish canine hematologic reference intervals according to International Federation of Clinical Chemistry and Clinical and Laboratory Standards Institute guidelines using the Sysmex XT‐2000iV hematology analyzer. Methods: Blood samples from 132 healthy purebred dogs from France, selected to represent the most prevalent canine breeds in France, were analyzed. Blood smears were scored for platelet (PLT) aggregates. Reference intervals were established using the nonparametric method. PLT and RBC counts obtained by impedance and optical methods were compared. Effects of sex and age on reference intervals were determined. Results: The correlation between impedance (I) and optical (O) measurements of RBC and PLT counts was excellent (Pearson r=.99 and .98, respectively); however, there were significant differences between the 2 methods (Student's paired t‐test, P<.0001). Differences between sexes were not significant except for HCT, PLT‐I, and PLT‐O. WBC, lymphocyte, and neutrophil counts decreased significantly with age (ANOVA, P<.05). Median eosinophil counts were higher in Brittany Spaniels (1.87 × 109/L), Rottweilers (1.41 × 109/L), and German Shepherd dogs (1.38 × 109/L) than in the overall population (0.9 × 109/L). PLT aggregates were responsible for lower PLT counts by the impedance, but not the optical, method. Conclusion: Reference intervals for hematologic analytes and indices were determined under controlled preanalytical and analytical conditions for a well‐characterized population of dogs according to international recommendations.  相似文献   

15.
Due to logistical problems in obtaining sufficient blood samples from apparently healthy animals in the wild in order to establish normal haematological reference values, only limited information regarding the blood platelet count and morphology of free-living lions (Panthera leo) is available. This study provides information on platelet counts and describes their morphology with particular reference to size in two normal, healthy and free-ranging lion populations. Blood samples were collected from a total of 16 lions. Platelet counts, determined manually, ranged between 218 and 358 x 10(9)/l. Light microscopy showed mostly activated platelets of various sizes with prominent granules. At the ultrastructural level the platelets revealed typical mammalian platelet morphology. However, morphometric analysis revealed a significant difference (P < 0.001) in platelet size between the two groups of animals. Basic haematological information obtained in this study may be helpful in future comparative studies between animals of the same species as well as in other felids.  相似文献   

16.
对湖北省通山县86只成年湖北乌羊的20项血液生理指标进行了测定,并比较分析了公母羊各项生理指标之间的差异。结果表明:白细胞总数17.99×109/L,淋巴细胞数7.30×109/L,单核细胞数1.53×109/L,粒细胞数8.60×109/L,血小板总数75.73×109/L,红细胞总数10.01×1012/L,血红蛋白含量85.64 g/L。其中,平均血红蛋白含量、平均红细胞体积、红细胞分布宽度、平均血小板体积和血小板分布宽度等5项指标在性别之间均差异极显著(P〈0.01),血小板压积在性别间差异显著(P〈0.05),其余14项血液生理指标在性别之间均没有显著性差异(P〉0.05)。  相似文献   

17.
Contrast-enhanced ultrasound is one of method for evaluating renal perfusion. The purpose of this project was to assess perfusion patterns and dynamics in normal micropig kidney using ultrasonographic contrast media. Eight young healthy micropigs were included in this study. Micropigs were anesthetized with propofol and received an intravenous bolus of microbubble contrast media through an ear vein. Time/mean pixel value (MPV) curves were generated for selected regions in the right renal cortex and medulla. The parenchyma was enhanced in two phases. The cortex was first enhanced followed by a more gradual enhancement of the medulla. A significant difference in perfusion was detected between the cortex and medulla. Following the bolus injection, the average upslope was 0.68 ± 0.27 MPV/sec, downslope was -0.27 ± 0.13 MPV/sec, baseline was 73.9 ± 16.5 MPV, peak was 84.6 ± 17.2 MPV, and time-to-peak (from injection) was 17.5 ± 6.6 sec for the cortex. For the medulla, the average upslope was 0.50 ± 0.24 MPV/sec, downslope was -0.12 ± 0.06 MPV/sec, baseline was 52.7 ± 7.0 MPV, peak was 65.2 ± 9.3 MPV, and time-to-peak (from injection) was 27.5 ± 5.0 sec. These data can be used as normal reference values for studying young micropigs.  相似文献   

18.
Platelet counts were performed in 50 cats presented for diagnostic investigation. For each cat, counts were obtained using a manual haemocytometer method and compared with counts obtained by estimation from a stained blood smear, a QBC VetAutoread analyser, a Zynocyte VS/2000 analyser, impedance automated counts on a Baker System using both EDTA and citrated anticoagulated blood, and use of a Zynostain modified counting chamber kit. None of the methods gave high correlation with the haemocytometer counts. The blood smear estimation of platelet counts had the highest correlation (r = 0.776) and was the only method to have reasonable values for both sensitivity and specificity. With the impedance automated counts, citrated anticoagulated blood had marginally higher correlation than EDTA anticoagulated blood, and the time between blood sampling and platelet count determination had no effect on the count obtained. When in-house analyser or impedance automated platelet counts are abnormal or not consistent with clinical findings, the authors recommend that a manual platelet count using either haemocytometry or examination of a blood smear is performed.  相似文献   

19.
The possibility of storage of canine platelet concentrates (PC) was investigated using PC from dogs which were obtained with an automatic cell separator in C4-cell separation sets with low gasdiffusionable Polyvinylchlorid (PVC) storage containers or in C4L-sets developed for storage with high gasdiffusionable Polyolefin (PO) containers, respectively. The storage was carried out for a period of 10 days under permanent agitation at 22 degrees C (C4/22 degrees C, n = 10; C4L/22 degrees C, n = 11) or at 4 degrees C (C4L/4 degrees C, n = 6), respectively. Measurements were done directly after production of the PC, after 6 hours and then daily during the 10-day storage period. In the first part of this paper the results of platelet count (determined automatically with a blood cell differentiation automat and visually), the number of platelet aggregates, the mean platelet volume (MPV) as well as the platelet function with regard to the platelet aggregation induced by collagen or ADP and the resonance-thrombogram (RTG) are presented. The platelet count, measured automatically as well as visually, remained preponderantly constant over the complete storage time in all storage conditions. Dependent on the storage conditions--especially under storage at 22 degrees C--an increase of the number of platelet aggregates and a decrease of MPV was determined. In addition, the loss of platelet function measured by aggregation induced by collagen as well as by ADP showed a significant dependency of storage conditions. The stored platelets lost their ability to aggregate under C4/22 degrees C-conditions after a storage period of 2 days, under C4L/22 degrees C-conditions after 4 days and under C4L/4 degrees C-conditions not before 8 days of storage. Previous resuspending of platelets in fresh plasma delayed the loss of platelet function. Because the loss of platelet function described in the RTG became significant at nearly the same point in time, a storage of canine PC under corresponding conditions can be recommended for upto 2 days (C4/22 degrees C), for 4 days (C4L/22 degrees C) or 8-10 days (C4L/4 degrees C), respectively.  相似文献   

20.
Background: Immature (reticulated) platelets (r‐PLT) are not routinely assessed by hematology analyzers, but may be useful in the evaluation of the bone marrow response to thrombocytopenia. Objective: The aim of this study was to compare the Sysmex XT2000iV hematology analyzer with standard flow cytometry for the determination of r‐PLT percentage in dogs. Methods: Blood samples were obtained from 40 healthy dogs, 12 thrombocytopenic dogs, and 6 dogs with normal platelet counts but with disorders associated with increased thrombopoiesis. The percentage of r‐PLT was determined with a FACscan flow cytometer (r‐PLT[F]) using CD61‐phycoerythrin antibody and thiazole orange, and with the PLT‐O channel of the Sysmex analyzer (r‐PLT[S]). Mean platelet volume, platelet distribution width, and platelet large cell ratio were also determined on the Sysmex. Repeatability (intra‐assay precision) and effect of storage were tested for the automated analyzer. Results: The reference interval (mean±1.96 X SD) for r‐PLT(F) was 1.91±1.29% (range 0.78–3.68%) and for r‐PLT(S) was 0.56±0.82% (range 0.11–2.16%). For both flow cytometry and the Sysmex, the patient group had a significantly higher mean percentage of r‐PLT compared with the control group (P<.0001, unpaired Student's t‐tests). Fair correlation (r=0.71; Spearman's regression analysis) was found for r‐PLT results between the 2 methods, and a negative proportional systematic bias of ?6.26 was found for the Sysmex (Bland–Altman analysis). Based on receiver operating characteristic curves and a cut‐off of ≥0.975%, a sensitivity of 94.7% and a specificity of 85.7% were obtained for detecting r‐PLT on the Sysmex, using flow cytometry as the reference method. Blood samples stored at 4 °C and 25 °C had a significant increase in the percentage of r‐PLT after 24 and 48 hours, respectively. Conclusions: The PLT‐O channel of the Sysmex XT2000iV is capable of detecting immature platelets in healthy, thrombocytopenic, and nonthrombocytopenic ill dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号