首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Haptoglobin and ceruloplasmin as determinants of inflammation in dogs.   总被引:1,自引:0,他引:1  
Assay procedures for determining serum haptoglobin concentration and ceruloplasmin oxidase activity in dogs were validated, and reference values were established. Serum haptoglobin concentration is reported as milligrams per deciliter of cyanmethemoglobin binding capacity, whereas serum ceruloplasmin oxidase activity was determined by use of p-phenylenediamine as substrate. Both assays were used to analyze serum samples from 288 dogs. In each dog's case record, clinical history and final diagnosis were evaluated to determine whether the dog had an inflammatory condition. Complete blood cell counts were performed in 265 dogs, using simultaneously collected blood samples. Plasma fibrinogen concentration was determined for 161 dogs. A positive correlation (P less than 0.01) for serum haptoglobin concentration and for ceruloplasmin oxidase activity, compared with WBC counts, segmented neutrophil and band neutrophil counts, and plasma fibrinogen concentration. Ceruloplasmin oxidase activity and haptoglobin concentration were up to 6 times more sensitive than fibrinogen concentration or leukocyte counts in detecting inflammation. Specificity of ceruloplasmin oxidase activity was comparable to fibrinogen concentration and leukocyte counts, whereas haptoglobin concentration was found to be slightly less specific. Specificity of haptoglobin concentration improved slightly (from 0.82 to 0.88) when dogs with a history of glucocorticoid administration were excluded from analysis. Predictive value of a negative test result (haptoglobin concentration less than 125 mg/dl; ceruloplasmin oxidase activity less than 20 IU/L) and predictive value of a positive test result for haptoglobin concentration and ceruloplasmin activity were comparable to or better than fibrinogen concentration or various oxidase leukocyte counts in detection of inflammation in a variety of disease conditions.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
A simple inexpensive method is described for determining plasma uric acid levels in companion birds. Plasma uric acid concentrations in 33 healthy parakeets were determined by a modification of the uricase spectrophotometric procedure utilizing 50 microliters of plasma. The mean uric acid level in parakeets was 5.60 mg/dl blood plasma, with no significant difference between males and females. In White Leghorn chickens, however, the mean level of uric acid in plasma was 7.19 mg/dl in males and 3.05 mg/dl in females. This method may be useful for the diagnosis and study of gout in small birds.  相似文献   

3.
The Incstar(R) SPQ II human haptoglobin (Hpt) (Incstar Corporation, Stillwater, MN) immunoturbidimetric assay was validated for the determination of serum and plasma Hpt concentrations in dogs and horses. The anti-human Hpt antiserum supplied with the assay, displayed monospecificity to both dog and horse serum Hpt by immunoelectrophoresis and Western blotting techniques. The automated immunoturbidimetric assay results correlated well with the cyanmethemoglobin binding assay (r=0.953 for canine serum and r=0.941 for equine serum), and had excellent precision at both high and low serum Hpt concentrations (within run and between run coefficients of variation near or less than 5%). The assay was linear in both species by serial dilution of pooled-high serum with pooled-low serum, saline and with Hpt-free serum. Interference from hemolysis (> 25 mg/dl hemoglobin) and lipemia greater than 100 mg/dl caused a false decrease and false increase respectively in Hpt yield with the immunoturbidimetric assay. The anti-Hpt antibody supplied with the assay kit, once diluted with polymer diluent and stored at 4 degrees C, was stable for up to 6 days and gave consistent results.  相似文献   

4.
Thyroid and immunologic status of dogs with perianal fistula   总被引:1,自引:0,他引:1  
Lymphocyte-proliferation responses, absolute lymphocyte counts, and thyrotropin-stimulation responses were determined in 33 dogs with perianal fistula; serum immunoglobulin values also were determined in 15 of the 33 dogs. Lymphocytes were stimulated with concanavalin A, pokeweed mitogen, and phytohemagglutinin and were cultured with medium containing normal pooled canine serum or fresh patient's autologous serum. Initially, lymphocytes from 9 dogs (27.3%) had depressed stimulation responses to greater than or equal to 1 phytomitogen, and 4 of the 9 dogs had absolute lymphopenia. One month after recovery in these 9 dogs, lymphocytes from 4 dogs (66.7%) had normal proliferation responses. Of immunoglobulin determinations in 15 dogs, serum IgA values were 32 to 185 mg/dl (mean, 69 +/- 10 mg/dl) and were low in 2 dogs (13%), and serum IgM values were 48 to 610 mg/dl (mean, 263 to 46 mg/dl) and were high in 8 dogs (53%). Serum IgG values were 1,050 to 3,220 mg/dl (mean, 2,339 +/- 165 mg/dl) and were high in 10 dogs (71%). After thyrotropin stimulation, 1 dog was considered hypothyroid. Neither pathogenesis nor prognosis of canine perianal fistula was clarified via immunoglobulin concentrations or absolute lymphocyte counts. Based on lymphocyte-proliferation assays, suppression of cell-mediated immunity was probably a result of perianal fistula, rather than a cause of the fistula.  相似文献   

5.
Haptoglobin is a positive acute-phase protein with a valuable role as a marker of inflammation in both human and veterinary medicine. The aim of this study was to validate a commercially available immunoturbidimetric method designed for human haptoglobin determination (Izasa SA, Barcelona, Spain) for its use in canine samples. Cross-reactivity between anti-human haptoglobin antiserum and canine haptoglobin was found when agarose gel immunodiffusion and ELISA tests were performed. The use of canine pooled serum with haptoglobin concentration of 6.3 g/L as standard provided higher analytical range than commercially available standards. Intra-assay and inter-assay coefficients of variation were 2.49% and 4.60%, respectively. A linear regression model between immunoturbidimetric results and a previously validated spectrophotometric method (Tridelta Development Limited, Ireland) yielded a slope at 95% confidence interval of 0.94 (0.86, 1.02) and y-intercept at 95% confidence interval of 0.11 (−0.59, 0.82). No significant differences were produced by anticoagulants, lipaemia and bilirubinaemia, although haemolysis significantly decreased haptoglobin. A significant increase of haptoglobin concentration was detected in inflammatory conditions such as pyometra and leishmaniasis, in neoplastic conditions, and after glucocorticoid administration. Canine serum haptoglobin concentration can be reliably measured using the commercially available Izasa immunoturbidimetric method developed for human haptoglobin determination. This method is precise and accurate, provides a wider analytical range than previous reported methods, and can be easily automated and used for routine haptoglobin determination in canine samples.  相似文献   

6.
A time-resolved immunofluorometric assay (TR-IFMA) was developed for the determination of haptoglobin (Hp) in canine serum. Haptoglobin was purified from canine acute phase serum by ammonium sulphate precipitation followed by gel filtration. This isolated dog Hp was used as the standard to calibrate the assay. Intra- and inter-assay coefficients of variation of the assay were, respectively, 5.7% and 16.6% at 0.51 mg/mL, 2.4% and 10.6% at 2.1 mg/mL and 10.5% and 11.9% at 32.5 mg/mL. The dilution of serum samples with high Hp concentrations resulted in linear regression equations with R2 of 0.99 and 0.97. A high correlation was found in serum Hp measurements by TR-IFMA and a commercial assay based on peroxidase activity of haemoglobin bound to haptoglobin (R2 = 0.96). The limit of detection for the TR-IFMA method was 0.002 microg/mL. The addition of fresh haemolysate to serum samples did not affect the haptoglobin concentration (P = 0.694). Statistical differences (P < 0.003) were found between healthy dogs and dogs with different pathological processes. In whole blood, Hp concentrations were much lower than in serum but closely related (R2 = 0.84) whereas saliva Hp concentrations were poorly related with serum concentrations (R2 = 0.53). However, the concentration of Hp in saliva was significantly (P < 0.039) higher in dogs with pathological processes compared to healthy dogs. The assay sensitivity was adequate to also be applied to whole blood and saliva specimens.  相似文献   

7.
试验开展了犬C-反应蛋白(C-CRP)荧光微球免疫层析定量方法的研究,旨在研制一种操作简易、灵敏度高,用于快速定量检测C-CRP荧光免疫层析试纸条。采用双抗体夹心法和荧光免疫层析技术,以羧基荧光微球标记的抗C-CRP单克隆抗体及羊抗鸡IgY为标记抗体,抗C-CRP单克隆抗体和鸡IgY分别作为检测线和质控线制备荧光免疫层析试纸条。结果显示,所制备C-CRP检测试纸条的检测范围为0.5~250mg/L,检测限为0.5mg/L,批内和批间变异系数(CV)分别为0.68%~6.94%和0.89%~8.79%,平均回收率为98.15%~101.19%,试剂与9种干扰物质无交叉反应。加速破坏稳定性试验表明试纸条可以常温放置24个月。临床样本测试发现,其与I-CHROMA试剂盒检测结果相关性良好(R2=0.995)。综上所述,该荧光免疫层析试纸条灵敏度、特异度较高,且操作简单、快速,可用于宠物犬临床检测。  相似文献   

8.
The alpha-macroglobulins are broad-specificity protease inhibitors important in the regulation and clearance from circulation of biologically active proteases. Inappropriate protease activation may be a feature of canine acute pancreatitis and the ability of the animal to clear these proteases may be important in determining survival. An enzyme immunoassay for the detection and measurement of canine alpha-macroglobulins in plasma samples was developed. A reference range for the canine alpha-macroglobulins of 1.20-2.72 mg ml-1 was established from a panel of canine plasma samples, and the stability of the alpha-macroglobulins in plasma samples stored at 4 degrees C was investigated. Changes in the level of the alpha-macroglobulins during disease states involving increased endogenous protease activity can now be investigated using a rapid, repeatable and quantifiable assay.  相似文献   

9.
A reproducible high performance liquid chromatography (HPLC) method was developed for analysis of uric acid in canine serum and urine. The method consists of precipitating serum proteins with phosphotungstic acid prior to HPLC analysis. Urine is analyzed after dilution with buffer. Chromatography is performed on a reversed-phase C-18 column with UV detection at 292 nm. Sensitivity of the method will allow reproducible measurement of uric acid at concentrations of 0.05 mg/dl in serum and 0.1 mg/dl in urine. The HPLC method has been used to quantify hundreds of canine serum and urine samples. The method is superior to UV absorption or colorimetric methods because its lower limit of detection allows measurement of uric acid at concentrations found in canine serum and urine.  相似文献   

10.
Serum magnesium (Mg) is an infrequnetly measured electrolyte in small animal patients. Currently, little is known about the prevalence and significance of abnormalities in serum Mg in animals. Therefore, a prospective study was performed to examine the incidence and clinical implications of abnormalities in serum Mg levels in critically ill dogs.
Serum Mg and other electrolytes were measured in 93 normal dogs housed at the Purina Pet Care Center and in 48 ill dogs admitted to a small animal critical care unit. The normal reference range for canine serum Mg was determined to be 1.89 – 2.51 mg/dl. Based on this range, 54% of the critically ill dogs were hypomagnesemic (< 1.89 mg/dl) and 13% were hypermagnesemic (> 2.51 mg/dl). Of the electrolytes measured in these patients, serum Mg had the highest prevalence of abnormal values. Hypomagnesemic patients had a significantly higher incidence of concurrent hypokalemia and hyponatremia (p < 0.05), as well as a longer length of hospitalization (p < 0.05) than their normomagnesemic counterparts. Hypermagnesemic patients were 2.6 times more likely not to survive their illness when compared to patients with normal serum Mg levels.
Abnormalities in serum Mg appear to be common in critically ill dogs. These patients commonly have other concurrent electrolyte abnormalities. Since serum Mg is not routinely measured, the presence of hypokalemia or hyponatremia should alert the clinician to the possibility of coexisting hypomagnesemia. The clinical implications of hypomagnesemia and hypermagnesemia in ill dogs appear to involve prolonged hospitalization and increased mortality, respectively: however, the exact etiology remains undetermined.  相似文献   

11.
The Veterinary Diagnostic Laboratory at Oregon State University received 172 aborted ovine fetuses during the 1985-1987 lambing seasons; from 120 of these, body fluids were evaluated for IgG levels. Fifty-two (43%) of the fetal fluids had immunoglobulin G (IgG) levels greater than 15 mg/dl. Forty-five (87%) of the fluids with elevated IgG levels were confirmed or presumed toxoplasma or chlamydia abortions. A mean fetal fluid IgG concentration of 111.5 +/- 78 mg/dl was found for the 26 toxoplasma abortions; for the 19 chlamydia abortions, a mean IgG concentration of 109 +/- 91 mg/dl was found. Antibody titers equal to or greater than 1:40 against Toxoplasma gondii were detected in 23 fetal fluids. Fetal fluid IgG concentration less than 15 mg/dl was found to be associated with bacterial organisms (i.e., Campylobacter sp.) as the confirmed or presumed cause of abortion. These results suggest that measurement of fetal fluid IgG concentration is a useful, supportive diagnostic test in determining the cause of ovine abortion, and should be included as a routine laboratory procedure for ovine abortion diagnosis.  相似文献   

12.
The critical difference values for acute phase proteins in canine serum samples were established on a week-to-week basis. Blood samples from 11 apparently clinically healthy dogs were collected once weekly for five consecutive weeks. For each protein the total variance of analytical results was divided into intraindividual variance (S(Intra)(2)), interindividual variance (S(Inter)(2)), and analytical variance (S(Analytical)(2)). The critical difference (d(K)) was then calculated as d(k)=22(S(Intra)(2)+S(Analytical)(2)). The critical difference values were 1.95 g/L for haptoglobin, 4.85 mg/L for C-reactive protein, and 0.016 DeltaAbs/min for ceruloplasmin. When used in conjunction with the corresponding reference interval, critical difference values can be an aid in correctly interpreting acute phase protein results, by determining whether observed differences between two consecutive measurements in individual animals are due to natural variation or due to disease therapy or experimental procedures.  相似文献   

13.
Pig-MAP (Major Acute-phase Protein) and haptoglobin concentrations were determined in pigs from commercial farms, and reference intervals obtained for different productive stages. Pig-MAP serum concentrations were lower in sows than in adult boars (mean values 0.81 vs. 1.23 mg/mL) and the opposite was observed for haptoglobin (1.47 vs. 0.94 mg/mL). No differences were found between parities, except for a minor decrease in haptoglobin concentration in the 4th parity. A linear correlation between pig-MAP and haptoglobin concentration was observed. In the period 4-12 weeks of life, pig-MAP mean concentrations were around 1mg/mL, being lower in the finishing period (0.7-0.8 mg/mL). Haptoglobin concentrations increased with time, from around 0.6 mg/mL at 4 weeks of age to 1.4 mg/mL at 12 weeks. Mean values of around 0.9 mg/mL were observed in the finishing period. A wider distribution of values was observed for haptoglobin than for pig-MAP concentrations. Differences between herds were observed, with the highest values obtained in a herd with signs of respiratory disease.  相似文献   

14.
OBJECTIVE: To determine the predictive ability of a commercially available lateral-flow immunoassay used for determining passive transfer of immunoglobulins in calves. ANIMALS: 204 male Holstein calves ranging from 4 to 8 days old. PROCEDURE: Serum samples were obtained from each calf. Results of refractometry, zinc sulfate turbidity technique, and the lateral-flow immunoassay were determined. Sensitivity, specificity, accuracy, and predictive ability were calculated on the basis of IgG concentrations determined by turbidimetric immunoassay (TIA). RESULTS: Mean IgG concentration in the study was 10.9 mg/ml as determined by TIA. Rate of failure of passive transfer in this study population was 56%. Associations between the values for the refractometry and zinc sulfate turbidity techniques were established by regression analysis. Accuracy for the lateral-flow immunoassay, refractometry, and zinc sulfate turbidity methods was 95, 80, and 73%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The lateral-flow immunoassay was better at determining the status of passive transfer of immunoglobulins, compared with the refractometry or zinc sulfate turbidity methods. The ability of the lateral-flow immunoassay to provide accurate results should enable clinicians to make immediate management or intervention decisions.  相似文献   

15.
Tumor necrosis factor-alpha (TNF) is a pleiotropic cytokine with profound and broad ranging effects on many cell types. There have been few publications investigating the role of TNF in spontaneous disease processes of dogs, particularly the role of this cytokine during endotoxaemia, shock and multiple organ dysfunction syndromes. Plasma samples taken at presentation from 60 dogs with spontaneous acute pancreatitis of varying severity levels (scored 0-4 in ascending severity) were assessed for TNF activity by bioassay and total TNF protein levels through a dot-blot immunoassay. TNF activity by bioassay was detected in 31% (4/13) of dogs presenting with severe disease (>50% expected mortality) as defined using a scoring system for organ compromise, and was not detectable in the remaining animals or healthy controls. TNF activity was detected in 66% (4/6) animals in the highest severity group (Score 4), these animals were showing severe multiple organ dysfunction. Total TNF protein levels, measured by dot-blot immunoassay, exhibited a wide range in all severity groups and healthy dogs. Dogs with detectable TNF activity were not distinguished from the other severity or healthy groups by immunoassay. The absence of detectable differences in total TNF protein levels between the various severity groups suggests that other factors may be crucial in determining the role of TNF in spontaneous canine acute pancreatitis and subsequent endotoxaemia and shock.  相似文献   

16.
The aim of this study was to validate an automated immunoturbidimetric assay used to quantify human albumin in urine and to accurately measure canine albumin concentrations in both urine and cerebrospinal fluid. The partial homology existing between human and canine albumin limited the accuracy of the human assays in measuring canine albumin without method modifications. Thus, the assay was modified by calibrating the analyzer with calibrators made in the laboratory containing known concentrations of canine albumin. To prepare the set of calibrators, the albumin concentration of pooled sera of healthy dogs was assessed in 5 replicates using the BromocresolGreen assay. Pooled samples were aliquoted and serially diluted to obtain the expected concentrations of albumin (0.5, 1, 5, 13, and 30 mg/dl) for establishing the canine calibration curve. Thereafter, the performance was assessed by analyzing canine urine and CSF The modified assay accurately quantified canine albumin in both specimens, as indicated by the following. Intra- and interassay variability was 0.92% and 2.74%, respectively; recovery was 99.66% and 99.07% in urine and 105.02% in CSF No interference was detected when hemolysate and glucose were added to urine. The test was linear within the verified range (0-225 mg/dl). These results demonstrate that the modified human albumin immunoturbidimetric assay can be a useful tool in the veterinary diagnostic laboratory. It is accurate and tends itself to automatization on chemistry analyzers.  相似文献   

17.
Abstract: Serum cystatin C often is used in humans as a rapid and more sensitive marker than serum creatinine for glomerular filtration rate. The purpose of the present study was to evaluate whether cystatin C-like immunoreactivity (CLI) could be measured reliably in canine serum and to investigate whether dogs with clinical renal insufficiency had higher CLI levels than did clinically healthy dogs and dogs with nonrenal diseases. A commercially available particle-enhanced turbidimetric immunoassay (PETIA) for human serum cystatin C was used to measure canine serum CLI in a linear and proportional manner, with a mean recovery of 104%± 7.5% and coefficients of variation of 1.7 to 9.6%. The assay was then applied to serum samples from 17 clinically healthy dogs, 12 dogs with nonrenal diseases, and 8 dogs with renal insufficiency. Serum CLI was significantly higher in dogs with renal insufficiency (median serum CLI = 5.01 mg/L) than in clinically healthy dogs and dogs with nonrenal diseases (median serum CLI = 1.06 mg/L and 1.62 mg/L, respectively). Thus, canine serum CLI could be reliably measured using a commercially available PETIA designed for human serum cystatin C, and dogs with clinical renal insufficiency had, as expected, significantly higher serum CLI levels.  相似文献   

18.
Serum haptoglobin (Hp) concentrations were measured in swine that were naturally or experimentally infected with Actinobacillus pleuropneumoniae. In swine from a specific-pathogen-free herd, mean serum concentration of Hp (+/- SD) was 5.79 +/- 1.06 mg of cyanmethemoglobin-binding capacity (CHBC)/dl. Serum Hp concentrations in paired samples were measured at 7-day intervals in 40 swine randomly selected from a conventional herd that was experiencing an acute episode of pneumonia and deaths caused by A pleuropneumoniae serotype-5 infection. Day-0 and -7 serum Hp concentrations were 24.58 +/- 1.38 and 23.10 +/- 1.12 mg of CHBC/dl, respectively, with no significant difference between these measurements. In a second conventional herd with a history of chronic infection with A pleuropneumoniae serotype 5, serum concentrations of Hp measured in paired samples obtained 6 days apart were 12.36 +/- 0.81 and 18.63 +/- 0.76 mg of CHBC/dl, respectively, and were significantly (P < 0.05) different from each other. Twenty-nine 12-week-old conventional swine were challenged intranasally with A pleuropneumoniae serotype 1 (n = 19) and serotype 5 (n = 10). Serum Hp concentration increased from prechallenge concentrations of 7.49 +/- 1.38 and 15.10 +/- 1.22 mg of CHBC/dl, respectively, to 41.01 +/- 1.35 and 22.37 +/- 1.78 mg of CHBC/dl, respectively, 72 hours after challenge. For these 29 swine, serum Hp concentration was positively correlated with rectal temperature (r = 0.34; P < 0.001) during the immediate postchallenge period.  相似文献   

19.
Concentrations of serum immunoglobulin (Ig) were determined for 30 channel catfish from pond water at 10 degrees C. These values were compared to measurements of 15 channel catfish from pond water at 30 degrees C. Channel catfish from 10 degrees C pond water had no significant (P greater than 0.05) different Ig concentrations (mean, 398 mg/dl) than catfish from 30 degrees C pond water (mean, 367 mg/dl). Serum Ig concentrations appear not to be different in cold (10 degrees C) vs warm (30 degrees C) pond water for 37.5-45 cm catfish. Channel catfish, 7.5-15 cm (n = 24) had significantly (P less than 0.05) lower Ig levels (mean, 104 mg/dl) than catfish either 7.5-25.5 cm (n = 57, mean, 232 mg/dl) or 37.5-45 cm (n = 45, mean, 388 mg/dl). Also, catfish 17.5-25.5 cm had a significantly (P less than 0.05) less Ig than catfish 37.5-45 cm. The concentrations of serum Ig increase with size (P = 0.0001) of catfish. The mean Ig concentration for 7.5-45 cm catfish (n = 126) was 263 mg/dl. The Ig concentration range was 44 to 650 mg/dl of serum.  相似文献   

20.
Objective : To evaluate the acute-phase protein response in dogs with parvoviral enteritis as predictor of the clinical outcome. Methods : Canine parvovirus infection was diagnosed based on the compatible clinical findings and confirmed by the canine parvovirus antigen test in 43 dogs of less than six months of age. Blood samples for complete blood cell count and acute-phase proteins (C-reactive protein, haptoglobin, ceruloplasmin and albumin) were collected before treatment. Twenty-three dogs died during or after treatment (non-survival) and the rest recovered (survival). Five healthy dogs were enrolled as control. Results : Serum C-reactive protein, ceruloplasmin and haptoglobin levels in dogs with parvoviral enteritis were higher (P<0·001, P<0·01 and P<0·001, respectively), but serum albumin was lower (P<0·001) than those in controls. Mean C-reactive protein and ceruloplasmin values in non-survival were higher (P<0·01) than those for survival dogs. C-reactive protein was found to be superior to ceruloplasmin, haptoglobin and albumin for distinguishing survival from non-survival dogs. Values higher than 92·4 mg/l for C-reactive protein had a sensitivity of 91% to predict mortality. Clinical Significance : The magnitude of the increase in serum acute-phase proteins in dogs with parvoviral enteritis could be a useful indicator of the prognosis of the disease. In acute-phase proteins, C-reactive protein is a potent predictor of mortality in dogs with parvoviral enteritis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号