首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study compared incisional complications after ventral midline laparotomy using 2 absorbable suture materials for apposition of the linea alba in sheep. The linea alba of 93 yearling sheep was sutured by 3 veterinarians in a simple continuous pattern using either polyglactin 910 (PG910; group PG) or polydioxanone (PDS; group PD). A blinded observer assessed surgical sites at the time of suture removal. Multivariate logistic regression was used to assess the association between incisional complications and variables (suture material used, veterinarian, skin suture removal time). The odds of incisional complications did not vary significantly with the type of suture material used (P = 0.11), veterinarian (P = 0.61) or skin suture removal time (P = 0.36). Most incisional complications were cutaneous suture sinus formation. Either PG910 or PDS may be used for linea alba closure in sheep.  相似文献   

2.
OBJECTIVE: To determine failure strength, stiffness, and failure mode of 4 suture materials in equine linea alba. STUDY DESIGN: Randomized complete block design. SAMPLE POPULATION: Linea albas collected from 12 adult horses (mean weight, 475 kg; mean age, 10 years). METHODS: The ventral abdominal fascia, including the linea alba, was collected and bisected along the linea alba into right and left halves. Each half was divided into four, 5-cm sections extending from the umbilicus cranially, and randomly assigned to 1 of 4 suture materials: 2 polydioxanone (2 PD), 3 polyglactin 910 (3 PG), 6 polyglactin 910 (6 PG), and 7 polydioxanone (7 PD). A single cycle to failure test was performed on each specimen at a distraction rate of 100 mm/min. Differences in failure strength and stiffness for the materials were evaluated using a mixed linear model with significance set at P<.05. RESULTS: In 94 of 96 test sections, constructs failed by suture failure. There were significant differences in failure strength (P<.0001) and stiffness (P<.001) among the suture/tissue constructs. 7 PD had the highest breaking strength (316.8 N) followed by 6 PG (281.3 N), 3 PG (229.9 N), and 2 PD (193.0 N). Six PG had the largest stiffness (14 N/mm) followed by 3 PG (12.7 N/mm), 7 PD (10.1 N/mm), and 2 PD (7.2 N/mm). Suture breaking strength and stiffness were not affected by linea or fascia thickness, individual horse, half of the linea alba, or abdominal wall position. Eighty-five (90.4%) suture loops failed adjacent the knot. CONCLUSIONS: When tested in single cycle to failure, suture material was more likely to fail than the linea alba. Larger suture materials had higher breaking strengths than smaller suture materials and stiffness was also affected by suture material and size. CLINICAL RELEVANCE: Given its high initial breaking strength and its relatively longer in vivo strength retention, 7 PD seems an appropriate choice of suture material for closure of the equine linea alba when maximal short-term failure strength is desired.  相似文献   

3.
Comparison was made of the healing of sutured prescrotal urethral incisions (12 dogs) with that of nonsutured incisions (6 dogs). Comparison was also made of the healing of 5-0 polyglactin 910-sutured urethral incisions (6 dogs) with that of 5-0 polydioxanone-sutured incisions (6 dogs). Three dogs from each treatment group were euthanatized 3 weeks and 6 weeks after the surgical procedure. Surgical sites were examined grossly, and urethral circumference measurements were taken at 3 locations (surgical site, 1 cm cranially, and 1 cm caudally). Transverse sections of the surgical sites were prepared and examined by light microscopy. Hemorrhage occurred postoperatively in dogs in which the incisions were not sutured. The surgical sites from the 6 dogs in which incisions healed by second intention had more fibrosis and less inflammation than did those that were sutured. There was little difference between incisions sutured with polyglactin 910 and those sutured with polydioxanone suture material. Postoperative urethral stricture formation did not occur in any of the dogs.  相似文献   

4.
The knot security of chromic gut, polyglycolic acid, polyglactin 910, polydioxanone, polypropylene, and monofilament nylon size 2-0 suture materials were tested biomechanically in vitro. Twenty reproducible knots were tied and incubated in canine serum at 37 degrees for 24 hours before testing. A "secure knot" was defined as a knot that, when tested to failure, broke rather than untied by slippage. The minimum number of throws necessary to make a secure, snug (1500 g tension) square knot was three for gut, polyglycolic acid, polyglactin 910, and polypropylene and four for polydioxanone and nylon. All throws including the first were counted. With all suture materials tested, surgeon's knots were as secure as square knots. Only gut, polyglycolic acid, and polydioxanone granny knots were as secure as square knots; no loosely tied (500 g tension) asymmetric square knots were as secure as snug square knots, and only polydioxanone and polypropylene loose square knots were as secure as snug square knots. Square knots used to start a continuous pattern required one additional throw with gut, polydioxanone, and nylon. Square knots used to end a continuous pattern required two to three additional throws with all materials tested.  相似文献   

5.
Polydioxanone (PDS™) synthetic absorbable suture material was evaluated in 169 dogs and cats. Sutures or ligatures were used on 446 tissues including 18 contaminated and 16 infected wounds. There was less tissue friction than with polyglycolic acid or polyglactin 910 sutures. The suture tended to kink during placement of continuous suture patterns. There was one wound dehiscence.
Polydioxanone may be used wherever surgical gut, polyglycolic acid, or polyglactin 910 sutures are normally used.  相似文献   

6.
Six enterotomies 3 cm long, spaced at 3 cm intervals, were made in the antimesenteric border of the pelvic flexure of the ascending colon in five adult horses. Ten incisions each were sutured with a Utrecht pattern (single layer), a full-thickness simple continuous oversewn with a Cushing pattern (two layer), and a mucosal simple continuous with a seromuscular simple continuous oversewn with a Cushing pattern (three layer). In all horses, chromic gut and polyglactin 910 were each used once for each pattern. On day 6, the pelvic flexure was excised and the colonic vessels were injected with a radio-opaque mass. Sections of each enterotomy were studied by light microscopy and high detail radiography. The single-layer closure led to serosa-to-mucosa healing and a thin bowel wall, and the three-layer closure resulted in distortion of the bowel wall by hematoma formation and submucosal contamination with ingesta. The two-layer closure resulted in good alignment and improved healing. There was less inflammatory reaction with polyglactin 910 than with chromic gut.  相似文献   

7.
OBJECTIVE: To evaluate closure strength (in vitro bursting pressure) of jejunal enterotomies in llamas. STUDY DESIGN: In vitro experimental study. SAMPLE POPULATION: Jejunal specimens (n=72) from 6 llamas. METHODS: Differences in bursting pressures and luminal diameters were compared between 2 layer enterotomy closures with an initial full thickness simple continuous pattern oversewn with either a continuous Lembert or Cushing suture pattern using 3 sizes (2-0, 3-0, 4-0) of polyglactin 910 and polydioxanone. RESULTS: Bursting pressures were significantly higher for enterotomies closed with polydioxanone than polyglactin 910, independent of suture size, but there was no difference between Lembert and Cushing oversew patterns. Use of a Lembert pattern reduced intestinal diameter more than a Cushing pattern regardless of suture material or size. CONCLUSIONS: Although polydioxanone resisted higher bursting pressures than polyglactin 910, both suture materials should be considered satisfactory for jejunal enterotomy closure in llamas based on typical intraluminal pressures expected in clinical patients. The optimal oversew pattern may be continuous Cushing to maximize the luminal diameter in small intestinal enterotomy closures. CLINICAL RELEVANCE: In vitro bursting pressures may help to predict which enterotomy sites would leak post-operatively, although further studies are necessary to determine the outcome in clinical patients.  相似文献   

8.
OBJECTIVE: To determine the bursting strength of ventral median abdominal incisions closed by either simple continuous or inverted cruciate suture patterns. STUDY DESIGN: Experimental. ANIMAL OR SAMPLE POPULATION: Twelve equine cadavers. METHODS: A 25 cm ventral median incision was made through the linea alba and a 200 L polyurethane bladder was placed within the abdomen. Either a simple continuous or an inverted cruciate pattern using 3 polyglactin 910 with a bite size and suture interval of 1.5 cm was used to close linea incisions. Closure time was recorded for each pattern. The bladder was inflated with air at 40 L/min, and the pressure at body wall failure recorded. The length of suture used for wound closure and the wound failure modes were recorded. Deviation from the linea (cm), total suture length (cm), suture length to wound length ratio (SL:WL), closure time (min), bursting pressure (mm Hg), and failure modes were compared between groups using Welch-Aspin t-tests. The effects of independent subject variables were assessed for possible effects on bursting strength using analysis of covariance. RESULTS: Mean bursting pressure was significantly greater for the simple continuous pattern than for the inverted cruciate pattern (P = .01). Significantly less suture material (P = .0002) was required with the continuous pattern than with the inverted cruciate pattern. Mean closure time, SL:WL, deviation from the linea, and failure modes were not significantly different between groups. No significant effects were noted for independent variables in both groups on bursting strength. CONCLUSIONS: In this model, a simple continuous closure pattern for ventral median abdominal incisions was stronger than an inverted cruciate pattern. A simple continuous pattern leaves less foreign material in the wound, which may be of benefit in reducing incisional complications. CLINICAL RELEVANCE: Use of a continuous closure pattern for the linea alba may offer greater wound security during episodes of increased intra-abdominal pressure in horses.  相似文献   

9.
10.
The purposes of this study were to mechanically determine the optimal tissue bite size and to evaluate seven suture materials at their largest commercially available size for breaking strength and stiffness using cadaveric adult equine linea alba. Soft tissues were removed from the abdominal fascia of 16 adult horses. Individual test sections were created from the entire linea alba and labeled (1 through 6) starting at the umbilicus and extending craniad. A single biomechanical test was performed on each test section. Tissue bite size (3, 6, 9, 12, 15, 18, and 21 mm) significantly altered breaking strength directly in a logarithmic fashion (P < .0001; R2= 0.94). Tissue bite size accounted for 44% and linea alba thickness for 24% of the variability in breaking strength of the equine linea alba. The optimal tissue bite size for adult horses was 15 mm from the edge of the linea alba based on lack of significant gain in breaking strength. There were no differences in breaking strength among horses, horses weight, or left and right test sections. Test sections taken from near or at the umbilicus had greater breaking strength (P < .005) and thicker linea alba (P < .001) when compared with more cranial test sections. Linea alba thickness alone accounted for 34% of the variability in breaking strength associated with test section position. There were no differences in linea alba stiffness among tissue bite sizes. All suture loops failed before complete fascial disruption, and 52 of 56 (93%) suture loops failed at the knot. Suture breaking strength and stiffness were significantly affected by the type of suture material examined (P < .0001). Size 5 polyester had a greater breaking strength and stiffness compared with the other suture materials tested. The next strongest suture materials were size 3 polyglactin 910 and size 2 polyglycolic acid, which were similar in breaking strengths and stiffness. Size 2 nylon was significantly weaker in breaking strength when compared with the other suture materials.  相似文献   

11.
Medical records of 210 horses that survived ventral midline celiotomy for at least 4 months were examined and owners were queried to determine factors contributing to incisional hernia formation. The incidence rate of incisional hernias within 4 months was 16%. Factors significantly associated with occurrence of incisional hernias were incisional drainage, closure of the linea alba with chromic gut suture material, previous midline celiotomy, excessive incisional edema, castrated male sex, postoperative leukopenia, and postoperative pain (colic). Factors not significantly associated with occurrence of incisional hernias were suture pattern used for linea alba closure, concurrent enterotomy or intestinal resection, postoperative bandage or stent, postoperative fever, hypoproteinemia, diarrhea, respiratory disease (coughing), and peritonitis. Hernias developed in horses within 12 weeks of surgery, with the earliest hernia recognized at week 2. Of 30 horses for which information was available, only one hernia developed in 24 (80%) and two or more hernias developed in 6 (20%) along the incision. Multiple hernias tended to be smaller than single hernias.  相似文献   

12.
Objective— To evaluate the effect of 6 different knotting methods on the mechanical properties of 3 large absorbable suture materials used in large animal surgery. Study Design— In vitro mechanical study. Sample Population— Knotted suture loops (n=15 per group). Methods— Suture loops were created between two low‐friction pulleys with either 2 polydioxanone, 2 polyglactin 910 or 3 polyglactin 910. Strands were tied using 1 of 6 knotting technique: square knot, surgeon knot, clamped surgeon's knot, sliding half‐hitch knot (HH), Delimar knot and self‐locking knot (SLK). A single cycle to failure test was performed on each suture loop with a distraction rate of 100 mm/min. Failure modes were evaluated and breaking strength, elongation to failure and stiffness were compared. Results— All loops except two HH failed at the knot by acute breaking. The double‐stranded SLK was both stronger and stiffer than all other knots for each suture material. Clamping the first throw of the surgeon knot decreased load to failure significantly (143.11 ± 8.64 N) compared with not clamping (159.21 ± 6.14 N) for polydioxanone. Stiffness and elongation to failure were respectively lower and increased for 2 polydioxanone compared with both polyglactin 910 materials for all knotting techniques. Conclusions— Knotting techniques do influence structural properties of suture loops. The double strand loop conferred stiffer and stronger properties to the SLK Clinical Relevance— Clamping the first throw of polydioxanone should be avoided when tying a suture under tension even using large diameter suture materials. Using a SLK might be considered as a useful alternative when excessive tension is present.  相似文献   

13.
Objective: To compare the mechanical, knotting, and absorption properties of 3 synthetic absorbable suture materials (polyglactin 910, polydioxanone, poliglecaprone 25) from 2 different manufacturers (Huaiyin Medical Instruments Co. Ltd. and Ethicon Inc.). Sample Population: Suture material samples from the same manufacturing lot for each suture type and manufacturer. Methods: Part 1: 10 samples of each suture were incubated in bovine serum and tested for ultimate load and stiffness at days 0, 1, 7, 14, 21, and 28. Part 2: 10 knotted samples were similarly evaluated, without incubation. Results: Huaiyin polydioxanone had a greater (P<.001) ultimate load on days 0, 1, and 7; and a consistently greater stiffness for the duration of the study, compared with the Ethicon polydioxanone. Ethicon poliglecaprone 25 had a greater ultimate load on days 0, 1, 7 (P<.001); on day 21 Huaiyin had a greater ultimate load. Ethicon poliglecaprone had greater stiffness on days 0, 1, 7 (P<.001). Ethicon polyglactin 910 had a greater (P<.001) ultimate load at all times and a greater stiffness (P<.001) at days 0, 1, 7, and 14 compared with Huaiyin polyglactin 910. Huaiyin polydioxanone and polyglactin 910 had greater knot breaking strengths than Ethicon equivalents (P<.001). Conclusion: Differences in mechanical properties exist between nominally identical suture materials from different manufacturers.  相似文献   

14.
This study compares the healing of oronasal defects created by partial maxillectomy when closed using two different suture materials and two different suture patterns. In experiment 1, 24 dogs were divided into four equal groups. Partial maxillectomy was performed on each dog and was closed using either a two-layer simple interrupted suture pattern (12 dogs) or a modified Mayo mattress pattern (12 dogs) with either polyglactin 910 (12 dogs) or polypropylene (12 dogs) sutures. On the seventh postoperative day, the dogs were euthanized, suture line bursting pressures were measured, and wound healing was evaluated grossly and histopathologically. Suture line dehiscence occurred in one dog from each of the four groups. These were the only dogs in which electrocoagulation had been used. The healing of suture lines closed with the two-layer simple interrupted pattern was superior to that of those closed with the modified Mayo mattress pattern based on the degree of gross oral ulceration, suppurative inflammation, fibrosis and oral epithelial covering at the suture line, and the number of necrotic sites in the adjacent tissue. The healing of suture lines closed with polypropylene was superior to that of those closed with polyglactin 910 based on suture line bursting pressures and the degree of suppurative inflammation and tissue necrosis at the suture sites. In Experiment 2, partial maxillectomies were performed on four dogs, and closure was achieved using a two-layer simple interrupted suture pattern with either polyglactin 910 (two dogs) or polypropylene (two dogs). On the 30th postoperative day, the dogs were euthanized, and wound healing was evaluated grossly and histopathologically. All suture lines were well healed. All polyglactin 910 oral sutures were absent, while all polypropylene oral sutures were still present.  相似文献   

15.
OBJECTIVE: To assess gross and histologic tissue responses of skin incisions closed by use of absorbable subcuticular staples, cutaneous metal staples, and polyglactin 910 suture in pigs. ANIMALS: 8 purpose-bred disease-free pigs. PROCEDURE: Pigs were randomly allocated to 1 of 4 groups from which tissues were collected after death on postoperative days (PODs) 7, 14, 21, or 42. In each pig, 4 incisions were made; 1 was closed subcuticularly with 3-0 polyglactin 910 suture, 1 was closed with metal staples, and 2 were closed with absorbable subcuticular staples. Incision sites were grossly evaluated every 3 days after closure. At necropsy, incision sites and surrounding tissues were examined histologically; a histopathologic scoring system was used to quantitate healing and tissue response directed against the closure material. RESULTS: Postoperatively, the metal staples induced a severe inflammatory response, compared with minimal inflammation associated with the suture or absorbable subcuticular staples. Histologic evaluation of incisions on PODs 7, 14, and 21 revealed less severe inflammation associated with absorbable subcuticular staples than that associated with the other materials. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that absorbable subcuticular staples induced a less severe inflammatory response in the early stages of healing in pigs, compared with other commonly used methods of wound closure. Use of absorbable staples potentially combines the benefits of subcuticular closure with the speed and precision of staple placement.  相似文献   

16.
Five different suture materials (silk, monofilament nylon, polyglyconate, polyglactin 910, and chromic gut) were placed in the skin and body wall of 10 Doitsu (scaleless) koi (Cyprinus carpio). After seven days the sutures were retrieved from five of the fish in 5 mm and 6 mm punch biopsies, and after 14 days they were retrieved in the same way from the other five. The tissue reactions were evaluated by gross visual inspection and by histological examination. The total inflammatory reaction was graded on a scale from 0 (no inflammation) to 5 (severe inflammation). The synthetic suture materials generally induced a moderate inflammatory reaction that decreased after seven days. After 14 days the superficial reaction to monofilament nylon was substantial, and the tissue reactions to the organic suture materials were slightly greater than the reactions to the synthetics. The inflammatory response to silk was greater after 14 days than after seven, and chromic gut induced a moderately severe inflammatory response after seven days; the chromic gut sutures fell out before the biopsies were taken after 14 days. The organic materials induced intense inflammatory reactions which did not subside if the suture remained in the tissue.  相似文献   

17.
Peritonitis was induced in 12 horses by median celiotomy and 1 hour of small intestinal ischemia. Six horses had primary closure of the incision, whereas six horses had a plastic mesh sutured to the ventral abdominal wall leaving the abdomen open for ventral drainage. The mesh was removed after 5 days and the abdominal wall was closed by apposition of the linea alba and subcutaneous tissues and approximation of the skin edges. Peritoneal fluid was collected and analyzed for nucleated cell count and total protein concentration on days 0 and 5. Serum biochemical profiles, serum electrolyte concentrations, and complete blood counts were performed on days 0, 1, 2, 5, 6, 10, and 14. Body weight, rectal temperature, and physical examination findings were recorded daily for 30 days, then horses were euthanatized and the abdominal cavity was examined for the presence of adhesions. Histological examination was performed to assess the inflammatory response of the healing body wall; inflammation scores were significantly lower in horses that had primary closure of the incision. The mesh was well tolerated by all horses and allowed egress of peritoneal fluid for 5 days. Adhesions were present in four control horses and in two horses that had open peritoneal drainage. All horses that had open drainage developed incisional infections after mesh removal. Abdominal wall herniation did not occur in any of the horses. The mild peritonitis induced in this study was insufficient to establish the efficacy of open peritoneal drainage for an established peritonitis in horses; however, the results of this study indicate that open peritoneal drainage is feasible in horses.  相似文献   

18.
OBJECTIVE: To determine a hand-tied ligature knot configuration, suture size, and suture type that would be an acceptable substitute to commercially available ligature knots for use in equine laparoscopic surgery. STUDY DESIGN: Three-factor ANOVA with the fixed effects being suture type, suture size, and knot type. The dependent variable was ligature security (load to failure). METHODS: Commercially available Endoloop and 4 hand-tied slipknot ligatures were compared with a 4-layer square knot. The hand tied ligature knots tested were the 4S modified Roeder knot, the Brooks knot, the modified Roeder knot, and the Weston knot. Two suture sizes (0, 2) of each of 2 suture types (polydioxanone, polyglactin 910) were tested with each hand tied knot. Two types (polydioxanone, polyglactin 910) of size 0 Endoloop were tested. Twenty repetitions of each knot suture type were tested for force to yield on a materials testing machine. Statistical analysis consisted of a 3-way ANOVA with individual comparisons made using the Bonferroni method. Significance was P< or = .05. RESULTS: Only the 4S modified Roeder knot in 2 polydioxanone (103 N) was comparable with the breaking strength of the square knots (157 N). All other knot suture combinations tested were significantly weaker than the square knot (range, 2-18 N). CONCLUSION: For equine laparoscopy, a 2 polydioxanone 4S modified Roeder knot would be an acceptable alternative to the commercially available Endoloop. CLINICAL RELEVANCE: Laparoscopic slip knots are commonly used in equine laparoscopic surgery. Various knot configuration and suture size and type combinations will affect the security of the slip knot.  相似文献   

19.
Reasons for performing study: Incisional complications are a major post operative challenge following ventral midline exploratory celiotomy for abdominal pain in horses. They lead to discomfort, prolonged hospitalisation, longer recovery times and increased cost; therefore, investigation of preventative procedures are warranted. Objectives: To determine the clinical effect of antibacterial (triclosan) coated 2‐0 polyglactin 910 suture material on the likelihood of incisional infections when used for closure of subcutaneous tissue following ventral midline celiotomies in horses. Methods: One hundred horses undergoing exploratory celiotomy assigned at random to one of 2 groups. In the control group coated 2‐0 polyglactin 910 (Vicryl) was used for apposition of the subcutaneous tissue in a simple continuous pattern and, in the study group, antibacterial (triclosan) coated 2‐0 polyglactin 910 suture material (Vicryl Plus) was used. Post operatively an elastic adhesive abdominal bandage was applied, changed and the incision was inspected by a clinician blinded to the study protocol at 24–36 h and 6–9 days post operatively. Outcomes of interest were evidence of incisional pain, incisional oedema, sheath/udder oedema, incisional drainage, hernia formation and dehiscence. Results: Antibacterial‐coated suture material did not decrease the likelihood of incisional complications in 100 horses. Conclusions: A beneficial effect on ventral midline incisions in 100 horses was not evident by using antibacterial‐coated suture material. Potential relevance: Lack of effectiveness of antibacterial‐coated suture material in equine ventral midline closure after exploratory celiotomy and the observed potential adverse effects suggest that further clinical investigations are needed before using such material routinely on horses.  相似文献   

20.
The loss of breaking strength and elasticity of five absorbable suture materials (polydioxanone [PDS-II], polyglycolic acid [PGA], polyglactin 910 [PG-910], polyglyconate [GTMC], and chromic gut) after in vitro incubation in sterile, Escherichia coli- and Proteus mirab/tfs-inoculated canine urine was studied. Biomechanical testing, in a controlled environment, was performed during the 28-day study period. Polydioxanone and chromic gut retained greater than 90% of their original strengths after 28 days of incubation in sterile urine and 87% of original strengths in E. co//-inoculated urine. Polyglyconate retained 24% and 18% of original strength, respectively, after incubation in sterile and E. co/i-inoculated urine for 28 days. Polyglycolic acid and PG-910 retained less than 30% of original strength in sterile urine and only 7% in E. co/i-inoculated urine after 21 days of incubation. In P. m/rabi/is-inoculated urine, loss of tensile strength and elongation was significant for all suture materials. Polyglycolic acid and PG-910 lost all strength after 24 hours of incubation. Polydioxanone lost all strength after 7 days of incubation, whereas GTMC retained 19% at day 7. Chromic gut retained 78% at day 7 and 16% after 21 days of incubation, however, the absence of normal phagocytic destruction of chromic gut in this in vitro study may have artificially elevated these values. In sterile urine with chemically modified pH, loss of strength and elongation was greater in alkaline urine than in neutral or acidic urine for all types of suture materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏