首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultrasound-guided percutaneous trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-) has been used to image the portal venous system in normal dogs. Compared with per-rectal portal scintigraphy, it provides higher count density, consistent nuclear venograms of the splenic and portal vein, and significantly decreased radiation exposures. This paper describes the use of TSPS for the diagnosis of portosystemic shunts in 28 dogs. TSPS was performed injecting 70 +/- 28 MBq of 99mTcO4(-) (mean +/- SD) into the splenic parenchyma with ultrasound guidance. A dynamic acquisition at a frame rate of four frames/s for 5 min was initiated after placement of the needle and approximately 2s prior to injection. All dogs had diagnoses confirmed via exploratory laparotomy or ultrasonographic identification of the shunting vessel(s). Three studies (10.7%) were nondiagnostic because of intraperitoneal rather than intrasplenic injection of the radionuclide. Three pathways were recognized on the scintigraphic images: (1) portoazygos shunts--the 99mTcO4(-) bolus traveled dorsally, running parallel to the spine and entering the heart craniodorsally; (2) single portocaval or splenocaval shunts--the 99mTcO4(-) bolus ran from the area of the portal vein/splenic vein junction in a linear fashion toward the caudal vena cava entering the heart caudally; (3) internal thoracic shunt-the 99mTcO4 bolus traveled ventrally along the thorax and abdomen entering the cranial aspect of the heart. Single and multiple shunts were easily distinguished. There were no distinguishing features between single intra and extrahepatic portocaval shunts.  相似文献   

2.
Objective— To evaluate trans-splenic portal scintigraphy (TSPS) and per-rectal portal scintigraphy (PRPS) for diagnosis of congenital portosystemic shunts (CPSS) in dogs, and compare these results with surgical findings.
Study Design— Prospective, randomized cross over clinical trial.
Animals— Dogs (n=42) with suspected CPSS.
Methods— Dogs had TSPS and PRPS 48 hours apart; quantity of radionuclide administered was recorded. Three independent, blinded reviewers evaluated each scintigraphic study for study quality, shunt presence, number, and location of shunt termination (caudal vena cava, azygos vein). All dogs had exploratory celiotomy. Negative scintigraphic findings were confirmed with intraoperative mesenteric portography. Ameroid constrictors were placed on all extrahepatic CPSS, and hepatic biopsies were obtained.
Results— TSPS was 100% sensitive and specific for diagnosis of CPSS and significantly ( P <.05) more likely than PRPS to detect shunt number and termination. Interpretation was consistent between observers, and TSPS required significantly less radionuclide than PRPS.
Conclusion— TSPS was as sensitive as PRPS for detection of shunting vessels, and consistently yielded studies of higher quality, allowing detection of shunt number and location with consistent interpretation among radiologists.
Clinical Relevance— TSPS provides information about shunt number and location, which allows improved surgical planning. Because it requires significantly less radionuclide, TSPS improves safety, allows for more comprehensive patient care, and earlier surgical intervention.  相似文献   

3.
Transsplenic portal scintigraphy using sodium pertechnetate is superior to per-rectal portal scintigraphy due to improved visualization of the portal vasculature with decreased patient and personnel exposure. The purpose of this study was to describe the use of 99mTc-mebrofenin, the radiopharmaceutical of choice for the evaluation of hepatic function, in place of pertechnetate for transsplenic portal scintigraphy in normal dogs. Sixteen juvenile dogs underwent transsplenic portal scintigraphy using 37-130 MBq 99mTc-mebrofenin in a 0.2-0.5 ml volume. After the initial dynamic acquisition obtained at 4 frames/s in right lateral recumbency, static right lateral, and ventral views were obtained at 5, 10, 15, 20, 25, 30, 40, 50, and 60 min. A nuclear angiogram of the splenic and portal veins was visible in all dogs, followed by rapid distribution of the radiopharmaceutical in the liver. Hepatic morphology was more easily defined than with pertechnetate. Transit time could not be calculated due to the high hepatic extraction of 99mTc-mebrofenin. Mean +/- SD shunt fraction was 0.8 +/- 0.8%. Time to peak liver activity was 3.1 +/- 1.1 min, and hepatic excretion T1/2 was 19.4 +/- 6.3 min. No visible blood pool and cardiac activity was seen after 5 min. The mean +/- SD time to visualization of defined biliary activity was 8.8 +/- 2.9 min. Absorption from the spleen was significantly higher than that reported for pertechnetate (87.9 +/- 8.2%, vs. 52.5 +/- 19.1%). 99mTc-mebrofenin can be used in place of pertechnetate for transsplenic portal scintigraphy, with the advantage of combining quantitative parameters of liver function with the already known advantage of transsplenic portal scintigraphy.  相似文献   

4.
Per rectal portal scintigraphy using 99mTechnetium pertechnetate (99mTcO4-) was used to diagnose portosystemic shunts (PSS) before surgical confirmation in seven dogs and two cats. Shunt fractions, representing the percent of portal blood that bypasses the liver, were determined by computer analysis of the scintigraphic images. Animals with portosystemic shunts had a mean preoperative shunt fraction of 84.02% (n = 9). The mean postoperative shunt fraction in four animals was 58.22%. The mean shunt fraction in ten control dogs was 5.00%. Per rectal portal scintigraphy is an innovative, easily performed, inexpensive method to diagnose congenital portosystemic shunts in dogs and cats.  相似文献   

5.
Nineteen cats with abnormally high serum T4 concentrations underwent thyroid scintigraphy using technetium-99m pertechnetate (99mTcO4) before and after 36 +/- 6 days of methimazole administration (approximately 2.5mg PO q 12 h). Thyroid-to-salivary gland ratios (T:S ratios) and percentage thyroidal uptake of injected radioactivity at 20 and 60min after injection of 99mTcO4 were compared before and after methimazole treatment. Serum thyroid stimulating hormone (TSH) concentration was measured before and after methimazole treatment. Quantitatively, there was a positive association between the thyroid uptake of 99mTcO4 and the serum T4 before treatment (r = 0.74-0.83). TSH suppression was present when cats were first evaluated for hyperthyroidism. Methimazole treatment did not relieve TSH suppression in 17 cats. Two cats with unilateral thyroid uptake developed bilateral, asymmetric thyroid uptake of 99mTcO4 after treatment and had the greatest increase in TSH concentration after treatment. Quantitatively, thyroid scintigraphy did not significantly change after methimazole treatment (P>0.1). Evaluation of serum TSH concentration may be helpful in identifying methimazole-induced changes in the scintigraphic features of hyperthyroidism in mildly hyperthyroid cats.  相似文献   

6.
Many hyperthyroid cats referred for thyroid imaging and 131I therapy are concurrently or recently receiving antithyroid medications. The effect of the antithyroid drug, methimazole, on thyroid uptake of 99mTcO4 and 123I was evaluated in 8 normal cats. Quantitative analysis was used to determine the normal percent dose uptake of 99mTcO4 and 123I, the change in thyroid:salivary ratios (T:S) of 99-TcO4 over time, and the duration of the methimazole effect on thyroid uptake of 123I. Methimazole was administered to 5 cats for 3 weeks in which a hypothyroid state was obtained; 3 cats served as non-treatment controls. 99mTcO4 and 8 and 24 hour 123I imaging was repeated after 3 weeks of methimazole therapy (time of maximum T4 suppression). Methimazole was then discontinued and 123I images and serum T4 concentrations were repeated at 1, 4, 9, 15, and 24 days post withdrawal. The percent dose uptake of 99mTcO4 increased throughout the acquisition period with maximum uptake occurring 4 hour post injection. The baseline 20 min. T:S ratio for controls and treatment cats were 0.79 +/- 0.08 and 0.81 +/- 0.05 respectively; with a peak value of 1.29 +/- 0.23 and 1.31 +/- 0.18 at 4 hours. The baseline T:S ratios were not significantly different from 20 minutes to 2 hours, however they were significantly elevated at 4 hours post injection. Baseline, 8 and 24 hour percent dose uptake of 123I were 2.1 +/- 0.42% and 7.04 +/- 1.24%, respectively. There was a significant increase in the T:S ratio in the treatment group at all time points. The 8 hour percent dose uptake of 123I at 1, 4, and 9 days post methimazole withdrawal were significantly increased and peaked at 4 days. The 24 hour uptake was significantly increased at 4 and 9 days, with peak uptake at 9 days post-methimazole withdrawal. The 123I percent dose uptake decreased to baseline values by day 15 post withdrawal. Radioiodine uptake is not inhibited by methimazole treatment in normal cats, and is significantly enhanced after recent withdrawal. This finding is supportive of a "short term rebund effect" with maximal enhanced uptake between 4 and 9 days after discontinuing antithyroid drugs. The increased uptake of 99mTcO4 may also affect the interpretation of 99mTcO4 thyroid scintigraphy for 2-3 weeks.  相似文献   

7.
This paper describes a simple methodology for evaluating the bacterial binding of ciprofloxacin labelled with technetium Tc 99m. Using this methodology, the binding of 99mTc-ciprofloxacin by live Escherichia coli was compared with the binding of 99mTc-ciprofloxacin by killed E. coli and the binding of 99mTc-pertechnetate (99mTcO4-) by live E. coli. The antimicrobial effect of 99mTc-ciprofloxacin on E. coli was evaluated. Four groups were defined: live E. coli with 99mTc-ciprofloxacin, live E. coli with 99mTcO4 , killed E. coli with 99mTc-ciprofloxacin, and killed E. coli with 99mTcO4-. After 0, 2, and 4 h of incubation of 1 x 10(8) colony-forming units of E. coli suspended in 5 mL of sterile distilled water with 1.85 MBq of 99mTc-ciprofloxacin or 99mTcO4, 1 mL from each sample was centrifuged. The radioactivity of the bacterial pellet and that of the supernatant were measured separately, and the percentage of sample radioactivity attributable to bacterial binding was calculated. Of the 99mTc-ciprofloxacin, 3.6% to 5.9% was bound to live or killed E. coli; only 0.1% to 0.2% of the 99mTcO4- was bound to live E. coli (P < 0.0001). No significant difference in 99mTc-ciprofloxacin binding was found between live and killed E. coli (P = 0.887). An antimicrobial effect on E. coli was seen with 99mTc-ciprofloxacin: colony counts were reduced after 4 h. The small amount of 99mTc-ciprofloxacin binding and the lack of difference in binding between live and killed E. coli may limit the utility of this methodology in evaluating the presence of E. coli infection.  相似文献   

8.
BACKGROUND: Differentiation between hypothyroidism and nonthyroidal illness in dogs poses specific problems, because plasma total thyroxine (TT4) concentrations are often low in nonthyroidal illness, and plasma thyroid stimulating hormone (TSH) concentrations are frequently not high in primary hypothyroidism. HYPOTHESIS: The serum concentrations of the common basal biochemical variables (TT4, freeT4 [fT4], and TSH) overlap between dogs with hypothyroidism and dogs with nonthyroidal illness, but, with stimulation tests and quantitative measurement of thyroidal 99mTcO4(-) uptake, differentiation will be possible. ANIMALS: In 30 dogs with low plasma TT4 concentration, the final diagnosis was based upon histopathologic examination of thyroid tissue obtained by biopsy. Fourteen dogs had primary hypothyroidism, and 13 dogs had nonthyroidal illness. Two dogs had secondary hypothyroidism, and 1 dog had metastatic thyroid cancer. METHODS: The diagnostic value was assessed for (1) plasma concentrations of TT4, fT4, and TSH; (2) TSH-stimulation test; (3) plasma TSH concentration after stimulation with TSH-releasing hormone (TRH); (4) occurrence of thyroglobulin antibodies (TgAbs); and (5) thyroidal 99mTcO4(-) uptake. RESULTS: Plasma concentrations of TT4, fT4, TSH, and the hormone pairs TT4/TSH and fT4/TSH overlapped in the 2 groups, whereas, with TgAbs, there was 1 false-negative result. Results of the TSH- and TRH-stimulation tests did not meet earlier established diagnostic criteria, overlapped, or both. With a quantitative measurement of thyroidal 99mTcO4(-) uptake, there was no overlap between dogs with primary hypothyroidism and dogs with nonthyroidal illness. CONCLUSIONS AND CLINICAL IMPORTANCE: The results of this study confirm earlier observations that, in dogs, accurate biochemical diagnosis of primary hypothyroidism poses specific problems. Previous studies, in which the TSH-stimulation test was used as the "gold standard" for the diagnosis of hypothyroidism may have suffered from misclassification. Quantitative measurement of thyroidal 99mTcO- uptake has the highest discriminatory power with regard to the differentiation between primary hypothyroidism and nonthyroidal illness.  相似文献   

9.
Diagnosing right-to-left congenital cardiac shunts can be difficult. Cardiac catheterization and angiocardiography represent the traditional gold standard for diagnosis, but they are invasive. Nuclear scintigraphy using 99mTc-macroaggregated albumin (MAA) has been employed in humans as an alternate method of diagnosis. This study reviews eight dogs presented for evaluation of a suspect right-to-left cardiac shunt that were examined using 99mTc-MAA. In all, 2-4 mCi (74-148 MBq) of reduced particle 99mTc-MAA were injected IV in a cephalic vein and static images of the whole body, including right and left lateral, dorsal, and ventral views, were acquired for 60 s and stored into a 256 x 256 x 16 matrix. Shunt fractions were calculated. One dog with radiopharmaceutical distribution limited to the lungs did not have a shunt. Seven dogs had distribution of the radiopharmaceutical outside the pulmonary capillary bed, indicating bypassing of the pulmonary capillary circulation due to a right-to-left shunt. Four dogs had 99mTc-MAA within the brain. Three dogs that did not have brain uptake, but instead had a sharp cutoff of radioactivity at the level of the front limbs and neck, were diagnosed with reverse patent ductus arteriosus (PDA). The asymmetric distribution of the radiopharmaceutical is due to the location of the shunt, distal to the brachiocephalic trunk and left subclavian artery. Shunt fractions of dogs with extrapulmonary radioactivity ranged from 40% to 59%. Nuclear scintigraphy with 99mTc-MAA is a quick alternative method of diagnosing right-to-left cardiac shunts that permits quantification of shunt fraction. Distinguishing between reverse PDA and other right-to-left shunts may be possible based on the radiopharmaceutical distribution.  相似文献   

10.
A nuclear imaging technique of the stomach, using technetium pertechnetate (99mTcO4), was evaluated in healthy dogs. The stomach was first insufflated with room air, then filled with barium sulfate to induce mild distention, outlining the gastric wall. Six dogs were imaged twice: initially without use of drugs that might affect gastric secretion of 99mTcO4, then after pretreatment with cimetidine and glycopyrrolate. These scans established the appearance of the normal (control) stomach and compared the quality of the image in the same dogs not pretreated, then pretreated with cimetidine and glycopyrrolate before administration of 99mTcO4. Avascular defects were then surgically created on the greater curvature of the stomach of the same 6 dogs, and gastroscintigraphy was performed in similar manner. Significant (P less than 0.05) quantitative differences were detected in the gastric images for scans of the avascular area, compared with various control scans. Qualitative assessment had overall accuracy of 90.28%. Results of the study reported here indicate that nuclear imaging can be a valuable diagnostic technique for detecting ischemic areas in the gastric wall of dogs.  相似文献   

11.
The purpose of this study was to evaluate nonuniform patterns of vascular distribution of pertechnetate in the dog during per-rectal portal scintigraphy. Ninety-two studies were reviewed retrospectively to document the patterns of radionuclide distribution. Forty-five studies were classified as normal and 47 were classified as diagnostic for a macrovascular portosystemic shunt. In these dogs, shunt fractions were calculated and compared using a t-test. In dogs with sufficient liver radioactivity for evaluation, the study was classified as having uniform, dorsal, central, or ventral radiopharmaceutical distributions. There were 51 animals (45 normal and six dogs with low-magnitude portosystemic shunts) with sufficient liver activity to assess the radionuclide distribution within the liver. A one-way ANOVA was used to compare shunt fractions between each of the distribution patterns. Two dogs were anesthetized and selective portovenograms were performed. Portovenograms were compared with the scintigraphic images to correlate the vascular distribution of the right, central, and left divisional branches of the portal vein. The shunt fraction in the 45 normal dogs was significantly lower than in the dogs with portosystemic shunts (5.7% +/- 4.8% vs. 78.6% +/- 20.0% (mean +/- SD), P < 0.001). Of the 51 dogs with sufficient liver activity to classify the pattern of distribution, there were 15/51 (31.4%) with uniform radionuclide distribution, 10/51 (19.6%) with focal dorsal distribution, 15/51 (29.4%) with focal ventral distribution, and 10/51 (19.6%) with focal central distribution. There was no significant difference in the shunt fractions between the groups. There were six dogs diagnosed with low-magnitude portosystemic shunt with sufficient liver radioactivity to categorize the vascular distribution of the radionuclide within the liver. Of these six dogs, two had focal dorsal distribution, one had focal central, one had focal ventral and two had uniform distribution. Focal dorsal distribution could result from streamlining of the radionuclide into the right divisional branch of the portal vein. Focal ventral distribution could result from streamlining the radionuclide into the left divisional branch of the portal vein. Focal central distribution could result from streamlining the radionuclide into the central divisional branch of the portal vein.  相似文献   

12.
To evaluate the use of technetium pertechnetate (99mTcO4) as a means of estimating gastric mucosal integrity, nuclear images of the empty stomach were obtained from 6 dogs at 20, 40, 60, 120, 180, and 240 minutes after IV administration of the radiopharmaceutical. Blood and gastric secretion samples were collected during the same time intervals. The left lateral-view image of the stomach was used to calculate the relative fraction of the dose in the stomach and the count density ratio. Between 20 and 40 minutes and 40 and 60 minutes, significant differences (P less than 0.001) were apparent in the amount of 99mTcO4 in the stomach. Blood concentration of 99mTcO4 decreased significantly (P less than 0.001), whereas gastric secretion concentration increased significantly (P less than 0.001) over time. Qualitative assessment of the gastric nuclear scans and the statistical analytic results indicated that the optimal time for imaging the canine stomach was between 40 and 60 minutes after radiopharmaceutical administration. In a second study, the same dogs were pretreated with the H2-receptor antagonist cimetidine and the cholinergic antagonist glycopyrrolate to block gastric secretions. Over time, changes in the relative dose fraction in the stomach and the density ratio were the same as values obtained during the experiment performed without use of cimetidine and glycopyrrolate. Results of the study indicate that nuclear imaging with 99mTcO4 outlines normal canine gastric mucosa and that pretreatment with cimetidine and glycopyrrolate has no effect on the quality of the gastric image.  相似文献   

13.
Philip D.  Koblik  DVM  MA  Chi-K  Yen  MD  William J.  Hornof  DVM  MS  Pamela  Whiting  DVM  Paul  Fisher  BS 《Veterinary radiology & ultrasound》1989,30(2):67-73
Transcolonic 123I-Iodoamphetamine is rapidly absorbed across the colonic mucosa and binds to amine receptors in the liver and lungs. During the first ten minutes following colonic administration, a simple ratio of lung counts to lung counts plus liver counts provides an accurate estimate of the fraction of portal blood that bypasses hepatic sinusoids in dogs with portosystemic shunts. Studies were performed on 24 dogs with suspect portosystemic shunt. Shunt fraction values for 18 dogs with surgically confirmed portosystemic shunt were obviously higher than published values for normal dogs, and also significantly higher than values for the other six dogs, later confirmed to lack shunts. Postoperative studies were repeated on ten dogs with single shunt vessels 1–2 days after shunt closure. Total shunt ligation resulted in normal postoperative shunt fraction, whereas partial shunt ligation resulted in persistant elevation of shunt fraction. Transcolonic iodoamphetamine scintigraphy is noninvasive, easy to perform, and provides an accurate method to diagnose dogs with portosystemic shunt.  相似文献   

14.
Gregory B.  Daniel  DVM  MS  Ronald  Bright DVM  MS  Eric  Monnet  DVM  Paul  Ollis  RT 《Veterinary radiology & ultrasound》1990,31(4):175-181
Per-rectal portal scintigraphy using tech-netium-99m pertechnetate (99mTcO4-) was performed in 8 normal dogs before and after surgical creation of a portacaval shunt. Shunt fractions were calculated by computer assisted analysis of dynamic images (IMG) and compared to shunt fractions determined by mesenteric venous injection of radioactive microspheres (MIC). The mean pre-operative shunt fraction was 1.59% using IMG and 3.00% using MCI. The mean postoperative shunt fraction was 64.56% using IMG and 69.56% using MIC. There was excellent correlation between both methods (r2 0.94). Per-rectal portal scintigraphy is an easily performed, inexpensive method to diagnose and quantify portosystemic shunts in dogs.  相似文献   

15.
OBJECTIVES: To determine the effect of sedation and anesthesia on thyroid and salivary gland uptake of technetium Tc 99m pertechnetate ((99m)TcO(4)) in euthyroid cats. ANIMALS: 6 euthyroid cats. PROCEDURES: Thyroid scintigraphy was performed by use of a high-resolution low-energy parallel-hole collimator after IV injection of 117 to 133 MBq (3.16 to 3.59 mCi) of (99m)TcO(4)(-). The procedure was performed 4 times on each cat during different sedative and anesthetic protocols in a rotating schedule as follows: propofol, ketamine-midazolam-atropine, ketaminemidazolam, and medetomidine. Regions of interest were drawn around thyroid and salivary glands and counts corrected for background and decay. Percentage of (99m)TcO(4)(-) uptake in salivary and thyroid glands and thyroid-to-salivary gland (99m)TcO(4)(-) uptake ratio were calculated at 20 and 40 minutes. Relative effects of anesthesia and sedation on salivary and thyroid gland (99m)TcO(4)(-) uptake were compared. RESULTS: Significant differences among sedativeanesthetic protocols were found for thyroid gland (99m)TcO(4)(-) uptake, salivary gland (99m)TcO(4)(-) uptake, and thyroid-to-salivary gland (99m)TcO(4)(-) uptake ratio. Thyroid gland (99m)TcO(4)(-) uptake for the ketamine-midazolam protocol at 20 and 40 minutes after (99m)TcO(4)(-) administration was significantly higher than for the propofol protocol. A significant difference in salivary gland(99m) TcO(4)(-) uptake was found between ketamine-midazolam and ketamine-midazolam-atropine protocols at 40 minutes. The thyroid-to-salivary gland (99m)TcO(4)(-) uptake ratio for the ketamine-midazolam protocol was significantly higher at 40 minutes than for propofol or ketamine-midazolam-atropine protocols. CONCLUSIONS AND CLINICAL RELEVANCE: Sedation and anesthesia have a significant effect on thyroid and salivary gland (99m)TcO(4) uptake in euthyroid cats that may interfere with thyroid scintigraphic image interpretation.  相似文献   

16.
OBJECTIVE: To investigate renal function in clinically normal dogs when awake and during anesthesia with medetomidine; xylazine, ketamine, and halothane (XKH) combination; or propofol. ANIMALS: 10 adult female Beagles. PROCEDURES: At intervals of 15 days, dogs were administered medetomidine (0.05 mg/kg, IV); XKH combination (xylazine [1 mg/kg, IV], ketamine [5 mg/kg, IV], and halothane [1% end-tidal concentration]); or propofol (6 mg/kg, IV) to induce anesthesia or no treatment. Glomerular filtration rate was assessed on the basis of renal uptake (RU; determined via renal scintigraphy) and plasma clearance (CL) of technetium 99m-labeled diethylenetriamine pentaacetic acid ((99m)Tc-DTPA). RESULTS: In awake dogs, mean +/- SEM RU was 9.7 +/- 0.4% and CL was 3.86 +/- 0.23 mL/min/ kg. Renal uptake and CL of (99m)Tc-DTPA were not significantly modified by administration of XKH (RU, 11.4 +/- 0.9%; CL, 4.6 +/- 0.32 mL/min/kg) or propofol (RU, 9.7 +/- 0.3%; CL, 3.78 +/- 0.37 mL/min/kg). Half-life elimination time of plasma (99m)Tc-DTPA decreased significantly in XKH-anesthetized dogs, compared with the value in awake dogs (14.4 minutes and 28.9 minutes, respectively). However, glomerular filtration rate was significantly decreased by administration of medetomidine (RU, 3.9 +/- 0.1%), and the time to maximum kidney activity was significantly increased (867 +/- 56 seconds vs 181 +/- 11 seconds without anesthesia). CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that anesthesia with propofol or an XKH combination did not alter renal function in healthy Beagles, but anesthesia with medetomidine decreased early RU of (99m)Tc-DTPA.  相似文献   

17.
Primary hypothyroidism in dogs is associated with increased release of growth hormone (GH). In search for an explanation we investigated the effect of intravenous administration of thyrotropin-releasing hormone (TRH, 10 microg/kg body weight) on GH release in 10 dogs with primary hypothyroidism and 6 healthy control dogs. The hypothyroid dogs had a medical history and physical changes compatible with hypothyroidism and were included in the study on the basis of the following criteria: plasma thyroxine concentration < 2 nmol/l and plasma thyrotropin (TSH) concentration > 1 microg/l. In addition, (99m)TcO(4)(-) uptake during thyroid scintigraphy was low or absent. TRH administration caused plasma TSH concentrations to rise significantly in the control dogs, but not in the hypothyroid dogs. In the dogs with primary hypothyroidism, the mean basal plasma GH concentration was relatively high (2.3+/-0.5 microg/l) and increased significantly (P=0.001) 10 and 20 min after injection of TRH (to 11.9+/-3.5 and 9.8+/-2.7 microg/l, respectively). In the control dogs, the mean basal plasma GH concentration was 1.3+/-0.1 microg/l and did not increase significantly after TRH administration. We conclude that, in contrast to healthy control dogs, primary hypothyroid dogs respond to TRH administration with a significant increase in the plasma GH concentration, possibly as a result of transdifferentiation of somatotropic pituitary cells to thyrosomatotropes.  相似文献   

18.
OBJECTIVE:To evaluate the use of a portocaval venograft and ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective, clinical study. Animal Population: Ten client-owned dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure greater than 8 mm Hg, a single extrahepatic portocaval shunt was created using a jugular vein. An ameroid ring was placed around the venograft and the intrahepatic PSS was attenuated. Transcolonic pertechnetate scintigraphy was performed before surgery, 5 days after surgery, and 8 to 10 weeks after surgery. Dogs with continued portosystemic shunting were evaluated further by laparotomy or portography. Clinical outcome and complications were recorded. RESULTS: Mean (+/- SD) portal pressure increased from 6 +/- 3 to 19 +/- 6 mm Hg with PSS occlusion; in all 10 dogs, the increase in portal pressure was greater than 8 mm Hg. There were no intraoperative complications, and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in 8 of 10 dogs. The final portal pressure was 9 +/- 4 mm Hg. Postoperative complications included coagulopathy and death (1 dog), ascites (3 dogs), and incisional discharge (3 dogs). Five of 8 dogs had continued portosystemic shunting at 8 to 10 weeks after surgery. Multiple extrahepatic PSS were demonstrated in 4 of these dogs. Clinical outcome was excellent in all 9 surviving dogs. CONCLUSIONS AND CLINICAL SIGNIFICANCE: The surgical technique resulted in a high incidence of multiple extrahepatic PSS. Short-term clinical results were promising, but long-term outcome must be evaluated further.  相似文献   

19.
OBJECTIVE: To compare hepatic, pancreatic, and gastric perfusion on dynamic computed tomography (CT) scans of clinically normal dogs with those of dogs with portal vascular anomalies. SAMPLE POPULATION: Dynamic computed tomography (CT) scans of 10 clinically normal dogs and 21 dogs with portal vascular anomalies. PROCEDURES: Retrospective analysis of dynamic CT scans. Hepatic arterial perfusion, hepatic portal perfusion, total hepatic perfusion, hepatic perfusion index, gastric perfusion, and pancreatic perfusion were calculated from time attenuation curves. RESULTS: Mean +/- hepatic arterial perfusion was significantly higher in affected dogs (0.57 +/- 0.27 mL/min x mL(-1)) than in clinically normal dogs (0.23 +/- 0.11 mL/min x mL(-1)), and hepatic portal perfusion was significantly lower in affected dogs (0.52 +/- 0.47 mL/min x mL(-1)) than in clinically normal dogs (1.08 +/- 0.45 mL/min x mL(-1)). This was reflected in the hepatic perfusion index, which was significantly higher in affected dogs (0.59 +/- 0.34), compared with clinically normal dogs (0.19 +/- 0.07). Gastric perfusion was significantly higher in dogs with portal vascular anomalies (0.72 +/- 0.44 mL/min x mL(-1)) than in clinically normal dogs (0.41 +/- 0.21 mL/min x mL(-1)), but total hepatic perfusion and pancreatic perfusion were not significantly different. Among subgroups, dogs with congenital intrahepatic portosystemic shunts and dogs with arterioportal fistulae had higher hepatic arterial perfusion than did clinically normal dogs. Dogs with congenital intrahepatic portosystemic shunts also had an increase in gastric perfusion and hepatic perfusion index. CONCLUSIONS AND CLINICAL RELEVANCE: Hepatic perfusion variables measured on CT scans revealed differences in hemodynamics between clinically normal dogs and those with portal vascular anomalies.  相似文献   

20.
Five mixed-breed dogs underwent splenic sequestration scintigraphy following intravenous injection of 647.5 to 740 MBq (17.5–20 mCi) of 99mTechnetium labeled autologous red blood cells (RBCs) that had been chemically denatured using two μg of stannous chloride. Left lateral dynamic images were obtained for 20 minutes after injection. Regions of interest (ROI) were drawn around the splenic body and ventral extremity, ventral liver and caudal abdominal great vessels and time activity curves created. Count density information was obtained and uptake ratios were calculated for the spleen ROI/vessel ROI, liver ROI/vessel ROI and spleen ROI/liver ROI at 1, 2.5, 5, 10, 15 and 20 minutes after injection. Two additional studies using different RBC denaturing procedures were done in four of the five dogs. In the second study, the stannous chloride level was doubled to 4.0 μg, while in the third study, the RBCs were denatured by addition of 2.0 μg of stannous chloride and heating at 49°C for 15 minutes. Progressive splenic uptake of denatured RBCs was seen in all dogs during the first 15 to 20 minutes of each study, no matter which denaturing technique was utilized. Significant increases in the spleen ROI:/vessel ROI and spleen ROI:liver ROI ratios were obtained at 5, 10, 15 and 20 minutes when compared to the 1 minute values for each of the labeling techniques. A significant difference was not identified between the three ratios at 15 minutes between the three labeling techniques. There was a trend of increasing values for each ratio where 2.0 μg of stannous chloride technique being the lowest, 4.0 μg of stannous chloride having an intermediate value and the heated technique had the highest values. The heating technique resulted in higher liver activity and increased variability of the mean liver ROI/vessel ROI ratios at all times (1, 2.5, 5,10, and 15 minutes). Using a non-linear least squares regression analysis, a double exponential equation fit the spleen ROI/vessel ROI and spleen ROI/liver ROI ratios for all three labeling techniques. Imaging of the spleen using all three techniques was acceptable, and a persistent blood pool image would allow for vascular imaging and cardiac gated studies 30 minutes after injection of the denatured, labeled autologous red blood cells. Veterinary Radiology & Ultrasound, Vol. 36, No. I, 1995, pp 57–63.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号