首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A polyclonal anti-gatifloxacin antibody has been prepared, and an indirect competitive enzyme-linked immunosorbent assay (cELISA) was developed on the basis of the antibody prepared for the first time. The antibody shows high sensitivity with an IC50 value of 2.6 ppb and excellent specificity with only a minor cross-reaction with lomefloxacin (3.0%) among common (fluoro)quinolones evaluated in this study. The high specificity of the antibody was explained by the molecular structures of related drugs by comparison with published research. The cELISA test kit developed has a detection limit of 0.05 ppb and could be used as a screening method to detect and regulate illegal use of gatifloxacin in food and food products. The test kit was applied to the detection of milk samples spiked by gatifloxacin. The recovery rates were in the range of 86-106%, whereas the intra- and interassay coefficients of variation were <14.3 and <19.6%, respectively.  相似文献   

2.
In this paper, a new monoclonal antibody (Mab) against sulfamethoxypyridazine (SMP) was produced, and a fluorescence polarization immunoassay (FPIA) based on the produced Mab was developed and optimized for the qualitative screening analysis of SMP. The Mab was raised from mice immunized with SMP linked to bovine serum albumin (BSA) by carbodiimide activated ester formation, using a succinic anhydride spacer molecule between SMP and BSA. Fluorescein labeled sulfachloropyridazine (SCP) and SMP (tracer) were synthesized and purified by thin layer chromatography (TLC). The developed screening FPIA method can tolerate up to 20% methanol, and satisfactory assay sensitivity can be obtained between pH 4 and pH 8 and at lower salt concentration. The anti-SMP Mab exhibited a high cross-reactivity with SCP. The effect of the tracer structure on the analytical characteristic of the determination and on antigen-antibody binding constants was studied. The limits of detection (LOD) were 0.7 ng/mL for SMP and 0.25 ng/mL for SCP in buffer, respectively, whereas negligible cross-reactivities were exhibited by related sulfonamides. Analysis of SMP and SCP-fortified milk samples by the FPIA showed average recoveries from 60 to 145%.  相似文献   

3.
An improved method has been developed for the determination of ethylene dibromide (EDB; 1,2-dibromoethane) in whole grains, milled grain products, intermediate grain-based foods, and animal feeds. Samples are mixed with water and sparged with nitrogen for 1 h with stirring in a water bath at 100 degrees C. The EDB collected on the adsorbent Tenax TA is eluted with hexane and determined by gas chromatography (GC) with electron capture detection (ECD) and confirmed with Hall electrolytic conductivity detection (HECD) using a second GC column. The highest levels of EDB were also confirmed by full scan GC/mass spectrometry (GC/MS). A total of 24 whole grains, milled grain products, intermediate grain-based foods, and animal feeds analyzed by using this method contained EDB levels up to 840 ppb (wheat). Recoveries from fortified samples ranged from 90 to 105%. Values from this method were compared with those obtained from the acetone soak method; for all 24 samples, this purge and trap method gave equivalent or superior recoveries and detected levels of EDB. Chromatograms for this purge and trap method were clean, enabling a quantitation level of 0.5 ppb to be achieved.  相似文献   

4.
A sensitive and accurate detection method is of great importance in monitoring fusaproliferin levels in foods and animal feeds and evaluating its potential hazard to human and animal health. Several methods have been developed to detect fusaproliferin in cereals and cereal-related products, including thin-layer chromatography, high-performance liquid chromatography, enzyme-linked immunosorbent assay, liquid chromatography-mass spectrometry (MS), gas chromatography (GC), and GC-MS. However, these detection methods either suffer from low sensitivity, need expensive instruments, or are susceptible to interfering substances in the sample matrix. The GC-flame ionization detector method developed herein is sensitive, reliable, and easy to use for detecting fusaproliferin in corn and corn-based samples. Its detection limits were 0.04 ng for standard trimethylsilyl-fusaproliferin and about 5 ppb for fusaproliferin in corn samples. The limits of quantitation of this method were 0.15 ng fusaproliferin/injection and 20 ppb of fusaproliferin in corn samples. The recovery rates of fusaproliferin from corn samples spiked with 200, 1000, and 5000 ppb standard fusaproliferin were 109, 85.7, and 98.9% on average. The repeatability of the method was acceptable when evaluated by the Horwitz equation. Of the tested corn samples, three out of five sweet corn and the three yellow corn samples were found to have low levels of fusaproliferin (9.4-45.3 ppb). A moldy corn sample had a fusaproliferin content of 297 ppb.  相似文献   

5.
Nine laboratories analyzed samples of whole grain, intermediate, and ready-to-eat products for ethylene dibromide (EDB) residues. Supplied samples of wheat, rice, and flour contained both fortified and incurred EDB; corn bread mix, baby cereal, and bread contained only fortified EDB. The whole grains and intermediates were analyzed by the same basic procedural steps as in the official method for multifumigants: They were extracted by soaking in acetone-water (5 + 1). The baby cereal and bread were analyzed by a modification of the Rains and Holder hexane co-distillation procedure. EDB was determined by electron capture gas chromatography operated with an SP-1000 column. All products contained 3 different levels of EDB and were analyzed as blind duplicates. Overall mean recoveries ranged from 85.2% for 69.6 ppb to 105.0% for 4.35 ppb, both in baby cereal. Interlaboratory relative standard deviations ranged from 5.7% for 869 ppb in wheat to 20.2% for 69.6 ppb in baby cereal, both fortified. Mean levels of incurred EDB in wheat, rice, and flour were 926.7, 982.0, and 49.9 ppb, respectively; corresponding relative standard deviations were 9.9, 7.7, and 13.1%. The method was adopted official first action.  相似文献   

6.
A method developed for the determination of ethylene dibromide in table-ready foods has been modified and expanded to include 7 other volatile halocarbons and carbon disulfide. Samples are stirred with water and purged with nitrogen for 0.5 h in a water bath at 100 degrees C. The analytes collected on a duplex trap composed of Tenax TA and XAD-4 resin are eluted with hexane and determined by gas chromatography with electron capture detection or Hall electrolytic conductivity detection. Flame photometric detection in the sulfur mode is used to determine carbon disulfide. Thick-film, wide-bore capillary columns are used exclusively in both the determination and confirmation of the halogenated analytes. The higher levels of analytes are also confirmed by full scan gas chromatography mass spectrometry (GC/MS). Samples are analyzed for carbon disulfide, methylene chloride, chloroform, 1,2-dichloroethane, methyl chloroform, carbon tetrachloride, trichloroethylene, 1,2-dibromoethane, and tetrachloroethylene. Initially, 19 table-ready foods from the Food and Drug Administration's Total Diet Study were analyzed by this method. A limited survey of those food items exhibiting high levels of analytes was conducted. Samples exhibited levels up to 3300 ppb (methyl chloroform in Parmesan cheese). Recoveries of all 9 analytes from fortified samples ranged from 83 to 104%. Chromatograms from this purge and trap method are clean, enabling quantitation levels of low parts per billion and sub-parts per billion to be achieved for the halogenated analytes. The quantitation limit for carbon disulfide is 12 ppb. Two compounds found in drinking water were identified by GC/MS as bromodichloromethane and chlorodibromomethane. Drinking water from several cities was analyzed for these trihalomethanes as well as for bromoform. Levels of up to 17 ppb bromodichloromethane were found. Recoveries ranged from 96 to 103%.  相似文献   

7.
An enzyme-linked immunosorbent assay (ELISA) for fipronil was developed by using polyclonal antibodies (pABs) or monoclonal antibodies (mABs), and its suitability of the determination of this analyte in spiked water samples was studied. The pABs-based assay showed I50 = 17.95 ppb, I90 = 203.40 ppb, and I10 = 0.066 ppb, whereas the mABs-based assay showed I50 = 5.99 ppb, I90 = 485.40 ppb, and I10 = 0.074 ppb. The recoveries of fipronil from tap water samples by pABs-based ELISA were 93.00-124.00% in the range of 0-500 ng/mL, and those obtained from the samples by mABs-based ELISA were 94.70-108.00%. Different types of water from pool, river, and sea were spiked at different levels (ranging form 0.1 to 10 microg/L) and were assayed by the indirect ELISA with mABs. The recoveries of fipronil by this ELISA were in the range of 80-120%. The results demonstrate that this assay is suitable for the quantitative detection of fipronil at trace levels in water samples.  相似文献   

8.
An improved method has been developed for the determination of ethylene dibromide (EDB, 1,2-dibromoethane) in a variety of table-ready foods. Samples are mixed with water and sparged with nitrogen for 1 h with stirring in a water bath at 100 degrees C. The EDB collected on the adsorbent Tenax TA is eluted with hexane and determined by gas chromatography (GC) with electron capture (EC) and confirmed with Hall electrolytic conductivity (HECD) detection using a second GC column. The highest levels of EDB were also confirmed by full scan GC/mass spectrometry (GC/MS). Twenty-five table-ready foods from the Food and Drug Administration's Total Diet Study that were analyzed by this method exhibited levels up to 70 ppb (pecans). Recoveries from fortified samples ranged from 91 to 104%. Values from this procedure were compared to those obtained by a modified Rains and Holder codistillation method. In all 25 samples this purge and trap procedure showed equivalent or superior recoveries and detected levels of EDB.  相似文献   

9.
A method was developed and validated to determine 5-hydroxyflunixin in raw bovine milk using liquid chromatography tandem mass spectrometry (LC/MS/MS). The mean recovery and percentage coefficient of variation (%CV) of 35 determinations for 5-hydroxyflunixin was 101% (5% CV). The theoretical limit of detection was 0.2 ppb with a validated lower limit of quantitation of 1 ppb and an upper limit of 150 ppb. Accuracy, precision, linearity, specificity, ruggedness, and storage stability were demonstrated. A LC/MS/MS confirmatory method using the extraction steps of the determinative method was developed and validated for 5-hydroxyflunixin in milk from cattle. Briefly, the determinative and confirmatory methods were based on an initial solvent (acetone/ethyl acetate) precipitation/extraction of acidified whole milk. The solvent precipitation/extraction effectively removed incurred ((14)C) residues from milk samples. The organic extract was then purified by solid phase extraction (SPE) using a strong cation exchange cartridge (sulfonic acid). The final SPE-purified sample was analyzed using LC/MS/MS. The methods are rapid, sensitive, and selective and provide for the determination and confirmation of 5-hydroxyflunixin at the 1 and 2 ppb levels, respectively.  相似文献   

10.
A liquid chromatographic method for the multiresidue determination of tetracyclines (TCs) in feeds is described. The levels of quantitation were 10 ppm each for tetracycline-HCl (TC), oxytetracycline (OTC), and chlortetracycline-HCl (CTC); the detection limit was 40 ppb for each. The calibration curves were linear between 2.5 and 100 ppm. The procedure involved double extraction with pH 2.0 and pH 4.5 McIlvain buffers, cleanup on a Sephadex LH-20 column, separation on a Nova-Pak C18 column, and detection at 370 nm. Recoveries of 10 micrograms/g of each TC in multiresidue feed samples ranged from 55.8 to 75.5% for OTC, 71.6 to 100% for TC, and 22.4 to 60.6% for CTC. The identities of the TCs were confirmed by thin layer chromatography.  相似文献   

11.
A collaborative study was conducted on the U.S. Food and Drug Administration (FDA) dichloromethane extraction method for determining volatile N-nitrosamines in baby bottle rubber nipples. Following dichloromethane extraction, N-nitrosamines were determined by gas chromatography-thermal energy analysis. Six pairs of blind duplicate rubber nipple samples representing 6 lots were analyzed by 11 collaborating laboratories. All samples were portions taken from equilibrated composites of cut-up rubber nipples obtained from manufacturers in the United States. Recoveries of the internal standard (N-nitrosodipropylamine) at approximately 20 ppb ranged from 10 to 120%. Reproducibility relative standard deviations (RSDx) were between 35 and 45% for N-nitrosamine levels from 10 to 20 ppb. However, when data from laboratories with recoveries less than 75% were excluded (this is now specified in the method), RSDx values were between 11 and 32% for N-nitrosamine levels from 6 to 26 ppb. Values were consistent with or better than those reported for other analytical techniques designed to quantitate trace contaminants at the low ppb level, e.g., aflatoxin in foods. The method has been adopted official first action for the quantitation of volatile N-nitrosamines in baby bottle rubber nipples.  相似文献   

12.
A multiresidue method was developed for the simultaneous determination of low parts per billion (ppb) concentrations of the herbicides alachlor, metolachlor, atrazine, and simazine in water and soil using isotope dilution gas chromatography/mass spectrometry (GC/MS). Known amounts of 15N,13C-alachlor and 2H5-atrazine were added to each sample as internal standards. The samples were then prepared by a solid phase extraction with no further cleanup. A high resolution GC/low resolution MS system with data acquisition in selected ion monitoring mode was used to quantitate herbicides in the extract. The limit of detection was 0.05 ppb for water and 0.5 ppb for soil. Accuracy greater than 80% and precision better than 4% was demonstrated with spiked samples.  相似文献   

13.
Patulin is a mycotoxin produced by mainly Penicillium species, for example, P. expansum, and Aspergillus species. There are several reports of patulin contamination in apple juice. Last year, the Ministry of Health, Labour and Welfare of Japan set the maximum allowable level of patulin in apple juice at 50 ppb and decided that the measurement of patulin levels in apple juice products should be conducted. To this end, a simple, accurate, and selective analytical method for the detection of patulin at levels lower than 5 ppb, the detection limit, is desired. This paper reports the development of an analytical method that employs solid-phase extraction-liquid chromatography-mass spectrometry (SPE-LC-MS). When MS measurements were conducted with the selected ion monitoring (SIM) mode, the pseudomolecular ions at m/z 153 and 156 were used to monitor patulin and (13)C(3)-labeled patulin, respectively. The detection limit (S/N = 3) and the quantification limit (S/N = 10) of patulin at injection levels into LC-MS were 12.5 and 25 pg, respectively. However, when the actual sample was applied for the analysis based on the developed method including the sample preparation, the detection limit (S/N = 3) and quantification limit (S/N = 10) were 2.5 and 5 pg in sample, respectively. The calibration curve obtained for concentrations ranging from 5 to 500 ppb showed good linearity with a coefficient of determination (r (2)) of 0.999. In addition, the recovery was >95% when an internal standard was used. The method was applied to the analysis of 76 apple juice samples from Japan, and as a result, patulin levels ranging from <1.0 to 45 ppb (detection frequency = 15/76) were detected. In this study, it was found that patulin was a greater contaminant in concentration/reduction than in "not from concentrate" apple juice.  相似文献   

14.
A simple and specific method able to identify and quantify traces of 14 sulfonamide antibacterials (SAs) in milk and eggs is presented. This method uses a single solid-phase extraction (SPE) cartridge for simultaneous extraction and purification of SAs in the above matrices. Milk and egg samples are passed through a Carbograph 4 sorption cartridge. After analyte desorption, an aliquot of the final extract is injected into a liquid chromatography-mass spectrometry (LC-MS) instrument equipped with an electrospray ion source (ESI) and a single quadrupole. MS data acquisition is performed in the positive-ion mode and by a time-scheduled multiple-ion selected ion monitoring program. Compared to two published methods, the present protocol extracted larger amounts of SAs from both milk and egg and decreased the analysis time by a factor of 3 with milk samples and by a factor of 2 with egg samples. Recovery of SAs in milk at the 5 ppb level ranged between 76 and 112% with relative standard deviations (RSDs) of 相似文献   

15.
Ethylene dibromide (EDB) levels in food samples were determined by gas chromatography with a high-resolution capillary column and electron capture detector. The capillary column used was 3 mm id X 25 m cross-linked 5% phenylmethyl silicone. Column temperature was set at 40 degrees C by a coolant containing carbon dioxide gas. Optimum temperatures of the injection port and detector were 200 and 350 degrees C, respectively. The detection limit was 0.5 ppb and linear from 1 to 20 pg on the dynamic range. EDB residues in food samples were extracted with n-hexane by steam distillation. A few impurity peaks appeared near EDB on the chromatogram; however, the EDB peak was resolved. Recoveries of EDB from wheat and brown rice ranged from 66.1 to 99.6%. EDB was detected in 3 samples of imported wheat at a range of 0.74-1.70 ppb, and was not detected at all in 37 samples. The EDB remaining in EDB-fortified cookies after baking was examined. The amounts of EDB were reduced to 30 to 50% of the original amounts by kneading the dough, and to below 1.5% by baking.  相似文献   

16.
A procedure has been developed and validated for measuring the concentration of pentobarbital residues in dry, extruded animal feed in the range of 3-200 ng/g (ppb) with an estimated limit of quantitation of 2 ppb. The method was developed for surveillance purposes: to measure the concentration of euthanizing agent which might be present in feeds incorporating rendered products which themselves might include some fraction of euthanized animals. A previously published qualitative procedure was modified by adding isotopically labelled pentobarbital as an internal standard. Dry feed was ground and extracted with methanol. The extract was loaded on a mixed-mode (C-18, anion exchange) solid-phase extraction cartridge designed for barbiturate residues. Pentobarbital was eluted and derivatized for gas chromatography/mass spectrometry in positive ion chemical ionization mode. Quantitation was based on the ratio of dimethyl-pentobarbital MH+ (m/z 255) vs dimethyl-pentobarbital-d(5) (m/z 260) in standards and extracts. Accuracy ranged from 112% at 3 ppb to 96% at 200 ppb, with relative standard deviations ranging from 4% at 3 ppb to 2% at 200 ppb.  相似文献   

17.
A gas-liquid chromatographic (GLC) method has been developed for the determination of the experimental herbicide 3,6-dichloropicolinic acid (Dowco 290) in soils. The method involves extraction of 1 g soil samples with 1N NaCl at approximately pH 7, methylation with diazomethane utilizing a microgenerator, and detection by electron capture GLC. Interferences are small, so that a cleanup step is not necessary even at the 6 ppb level. The procedure is rapid, requiring only 45 min/sample. Recoveries range from 84 to 94% at the 6-1000 ppb level with a minimum detectable limit of 6 ppb. Standard deviations for the percentage recovery values vary from 10.9 to 2.3 for the tested range of 6.7-670 ppb, respectively.  相似文献   

18.
A previously developed method that uses a simplified sample preparation and fluorometric detection of liquid chromatographic eluates for the determination of oxolinic acid in salmon muscle has been collaboratively studied. Five laboratories participated in the study to analyze, in quintuplicate, blank salmon muscle fortified at 10, 20, 50, and 100 micrograms/kg (ppb), and 2 incurred samples from salmon given feed with medicated oxolinic acid. The tissue, 2 g mixed with 2 g Na2SO4, is extracted with ethyl acetate and centrifuged, and the solvent is evaporated. The residue is partitioned in a mixture of hexane and 0.01 M oxalic acid, and the aqueous phase is chromatographed using fluorescence detection at 327 nm excitation and 369 nm emission. Mean recoveries ranged from 77.2 to 84.5% in spiked samples with reproducibility relative standard deviation (RSDR) ranging from 11.5 to 18.3%. Treated salmon were found to contain 8.71 and 53.8 micrograms/kg with RSDR of 18.6 and 16.7%, respectively. The corresponding repeatability relative standard deviations (RSDR) were 5.8-12.2%, and 7.7 and 6.2%. The method is recommended for regulatory purposes in Canada.  相似文献   

19.
This paper describes a new method for the rapid extraction and unequivocal confirmation of 13 sulfonamides (SAs) in raw meat and infant foods. The highly automated extraction procedure is based on accelerated solvent extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a confirmatory analysis. After 1 g of food matrix was blended with 2 g of C18 as a solid support material, the mixture was packed into the extraction cell and the SAs were extracted with 10 mL of hot water at 160 degrees C and 100 atm; 100 microL of the extract was directly injected into the LC-MS system. The analytes were ionized in an electrospray interface operating in the positive ion mode and were identified by selecting two multireaction monitoring transitions, which guaranteed method specificity. Typical recoveries from crude meat and baby food samples ranged from 70 to 101% at a fortification level of 100 ppb, corresponding to the maximum residue limits established by the European Union and the U.S. Food and Drug Administration. The interday method precision was less than 8.5%, and the limits of detection were below 2.6 ppb. This study has taken matrix-induced suppression of ionization into account, by comparing standard and matrix-matched calibration curves. Four of the 13 monitored SAs have been detected in some baby foods and raw meat samples, bought from Roman supermarkets and butchers' shops, using the described methodology.  相似文献   

20.
A method is described for the simultaneous quantitation of trace amounts of alpha- (alpha-NA) and beta-naphthylamines (beta-NA) with detectability in the 0.1 ppb range and sensitivity of 50 picomoles in certified food grade amaranth (FD&C Red No. 2; C.I. Food Red 9; CI 16185). The amaranth sample is extracted with benzene, and the evoporated residue is derivatized with perfluorooctanoic anhydride. The resulting derivatives are separated by gas-liquid chromatography and identified and quantitated by mass spectrometric monitoring of the m/e at 539.04. The method was used for quantitation of alpha-NA and beta-NA in randomly chosen samples of amaranth. Of 11 samples from different manufacturers, 5 were free of the beta-isomer; the remaining samples contained up to 1.2 ppb beta-NA. The concentration of alpha-NA ranged from no detectable amount to 970 ppb; the majority of the samples contained less than 7 ppb.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号