首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This report describes the results of CT-guided stereotactic brain biopsies performed on 50 consecutive dogs using a modified Pelorus Mark III Stereotactic System. Based on available histopathologic samples (stereotactic biopsy [n = 50], surgery [n = 17], necropsy [n = 9]) the patient population consisted of 34 dogs with primary brain tumors, 2 with invasive nasal adenocarcinomas, and 13 with non-neoplastic brain lesions. Brain tissue was not obtained from one dog. In 22 dogs a final diagnosis was made from tissue subsequently obtained from surgical resection or at necropsy. The final diagnosis was in agreement with the stereotactic biopsy diagnosis in 20 of these 22 dogs. In 17 other dogs without follow-up, stereotactic biopsy provided a diagnosis of a specific primary brain tumor subtype. Postoperative complications associated with the biopsy procedure were assessed in 41 dogs. The other 9 dogs either went directly to surgery (n = 7) or were killed (n = 2) immediately after the biopsy procedure. Thirty-six dogs recovered without apparent clinical complications. Postoperative clinical complications in the remaining 5 dogs included transient epistaxis (1 dog), transient exacerbation of cerebellar signs (1 dog), obtundation progressing to coma (1 dog), and medically uncontrollable seizures (2 dogs). The latter 3 dogs with severe neurologic complications all had large primary brain tumors and had been receiving high doses of phenobarbital and glucocorticoids to control seizures at the time of biopsy. These results suggest that this CT-guided biopsy procedure can provide an accurate pathologic diagnosis of brain lesions detected by CT and MR neuroimaging. Further refinement of both technique and case selection is expected to reduce the rate of clinical complications and to improve the accuracy of the procedure.  相似文献   

2.
A stereotactic brain biopsy system that is magnetic resonance (MR) imaging-guided has not been validated in dogs. Our purpose was to determine the mean needle placement error in the caudate nucleus, thalamus, and midbrain of a canine cadaver brain using the modified Brainsight stereotactic system. Relocatable reference markers (fiducial markers) were attached to the cadaver head using a dental bite block. A T1-weighted gradient echo three-dimensional (3D) sequence was acquired using set parameters. Fiducial markers were used to register the head to the acquired MR images in reference to a 3D position sensor. This allowed the planning of trajectory path to brain targets in real time. Coordinates (X, Y, Z) were established for each target and 0.5 microl of diluted gadolinium was injected at each target using a 26-gauge needle to create a lesion. The center of the gadolinium deposition was identified on the postoperative MR images and coordinates (X', Y', Z') were established. The precision of this system in bringing the needle to target (needle placement error) was calculated. Seventeen sites were targeted in the brain. The mean needle placement error for all target sites was 1.79 +/- 0.87 mm. The upper bound of error for this stereotactic system was 3.31 mm. There was no statistically significant relationship between needle placement error and target depth (P = 0.23). The ease of use and precision of this stereotactic system support its development for clinical use in dogs with brain lesions > 3.31 mm.  相似文献   

3.
This report describes computed tomography (CT)-guided stereotactic brain biopsy using the Kopf stereotactic system, a commercially available patient restraint system which does not require additional modification for use in small animals. The accuracy of biopsy needle placement was determined by injecting dilute iohexol into cadaver brains and comparing the three-dimensional coordinates of the desired target location to the actual needle tract observed on postcontrast CT images. Overall mean error in needle placement in a dorsoventral trajectory was 0.9 +/- 0.9 mm (n = 80 injections) for dogs and 1.0 +/- 1.1 mm (n = 30 injections) for cats. The overall mean error in needle placement via an oblique trajectory in five dogs was 1.7 +/- 1.6 mm (n = 12 injections). These results suggest that this system can be used to successfully place a biopsy needle into the brain to obtain biopsies from small lesions.  相似文献   

4.
Alain  Giroux  DVM  MS  Jeryl C.  Jones  DVM  PhD  Jan Helge  Bohn  MS  PhD  Robert B.  Duncan  DVM  PhD  Don R.  Waldron  DVM  Karen R.  Inzana  DVM  PhD 《Veterinary radiology & ultrasound》2002,43(3):229-236
An inexpensive device was created for computed tomographic (CT)-guided stereotactic biopsy of the canine brain. The accuracy of the device was tested using 16, formalin-perfused, canine head specimens. For each dog, a 6-inch biopsy needle was guided into pituitary gland and caudate nucleus targets. Needle tracks were measured using the CT computer and infused with tissue staining solution. Hit success and actual needle track lengths were determined from sliced brain specimens. The device enabled accurate orientation and placement of the canine head in the slice plane, such that progressive penetration of the biopsy needle could be monitored. The caudate nucleus was hit 12/16 times (75% accuracy) and the pituitary gland 15.5/16 times (98.6% accuracy). Hit proportions for the two targets did not differ (P < 0.05). A significant difference was found between CT and actual track length for both targets (P < 0.01). This was attributed to incomplete staining of the bevel portion of the needle track.  相似文献   

5.
This study evaluated the accuracy of a new stereotactic CT-guided brain biopsy (SCTGBB) device on 23 client-owned dogs which presented with a brain lesion. Biopsy of the lesion was achieved in 95 per cent of cases. The target tissue was not sampled in one dog. Complications were observed in six dogs. Two dogs with highly vascularised brainstem tumours died after SCTGBB. Minor complications (slight variation in the neurological status) were observed in a further four cases. A diagnosis was reached in 16 dogs after cytological examination and in 21 dogs after histological evaluation. SCTGBB is an accurate diagnostic method for the diagnosis of brain lesions.  相似文献   

6.
The accuracy testing of a new CT -guided stereotactic device was undertaken via an experimental study. Ten dog cadaver heads were submitted to a CT examination and a brain target was determined (coordinates: x1, y1, z1). 0.3 ml of a radiopaque paste was injected in this chosen point. The head was analysed twice by CT and the centre of the injection (x2, y2, z2) was measured on slices. Tridimensional statistical analysis of the variance of the two points was carried out. The procedure always led to the injection of the radiopaque paste and created an intracerebral mass which gave a measurable image on CT examination. The distance between the original target and the centre of the injection was 2.9 +/- 1.08 mm. It is concluded that this new device allows the opportunity to perform stereotactic CT -guided brain biopsy for all unknown brain lesions exceeding 6 mm in diameter in the dog.  相似文献   

7.
Intracranial tumours occur relatively frequently in dogs, and less commonly in cats. With the availability of computed tomography (CT) and magnetic resonance imaging, more accurate determination of the location and extent of brain tumours in companion animals has become possible. Following these advances in imaging, precise CT-guided stereotactic techniques for both tumour biopsy and intratumoral drug delivery have been developed for use in cats and dogs. Also, tumour identification methods, such as crush preparation examination, have facilitated rapid tumour identification. The use of improved diagnostic techniques has resulted in an increasing demand for effective therapies for brain tumours. While surgical removal and irradiation remain important treatment considerations in the management of brain tumours of cats and dogs, the development of gene therapy strategies for treatment of intracranial tumours offers much promise, although research in this area is still at an early stage.  相似文献   

8.
BACKGROUND: Per-catheter patent ductus arteriosus (PDA) occlusion in dogs with devices intended for humans is associated with technical difficulties, high rates of procedure abandonment, device migration, and residual ductal flow. HYPOTHESIS: Use of a custom-made canine duct occluder (Amplatz Canine Duct Occluder, ACDO) would be feasible in dogs of varying weights and somatotypes and effective in occluding a wide range of PDA shapes and sizes. ANIMALS: Eighteen client-owned dogs of various breeds with PDA. Weights ranged from 3.8 to 32.3 kg (median, 17.8 kg), and angiographic minimal ductal diameters ranged from 1.1 to 6.9 mm (median, 3.7 mm). Ductal morphologies included types IIA, IIB, and III. METHODS: Per-catheter PDA occlusion with the ACDO was performed in all dogs. Persistent or recurrent ductal flow was assessed at the end of the procedure by angiography and at 1 day, 3 months, and >or=12 months after the procedure by echocardiography. RESULTS: Successful ACDO placement was achieved in all 18 dogs. One dog required a 2nd procedure with a larger ACDO after the 1st device migrated to the pulmonary vasculature. Complete occlusion was confirmed in 17 of 18 dogs during the procedure, as well as at 1 day and 3 months after the procedure, and in 12 of 13 dogs evaluated at >or=12 months after the procedure. CONCLUSIONS AND CLINICAL IMPORTANCE: Per-catheter PDA occlusion in dogs with the ACDO is feasible and effective in dogs of a wide range of weights and somatotypes and with PDAs of varying shapes and sizes.  相似文献   

9.
Although glioblastoma multiforme (GBM), a World Health Organization grade IV astrocytoma, is the most common primary brain tumor in humans, in dogs GBM is relatively rare, accounting for only about 5% of all astrocytomas. This study presents combined clinical, neuroimaging, and neuropathologic findings in five dogs with GBM. The five dogs, aged from 5 to 12 years, were presented with progressive neurologic deficits that subsequent clinical neurologic examination and neuroimaging studies by magnetic resonance imaging (MRI), localized to space occupying lesions in the brain. MRI features of the tumors included consistent peritumoral edema (n = 5), sharp borders (n = 4), ring enhancement (n = 3), heterogenous T2-weighted signal intensity (n = 3), iso- to hypointense T1-weighted images (n = 5), necrosis (n = 5), and cyst formation (n = 2). Two tumors were diagnosed clinically using a computed tomography-guided stereotactic biopsy procedure. At necropsy all the tumors resulted in, on transverse sections, a prominent midline shift and had a variegated appearance due to intratumoral necrosis and hemorrhage. Histologically, they had serpentine necrosis with glial cell pseudopalisading and microvascular proliferation, features which distinguish human GBM from grade III astrocytomas. Immunoreactivity of tumor cells for glial fibrillary acidic protein was strongly positive in all cases, whereas 60% and 40% of the tumors also expressed epidermal growth factor receptor and vascular endothelial growth factor, respectively. These canine GBMs shared many diagnostic neuroimaging, gross, microcopic, and immunoreactivity features similar to those of human GBMs.  相似文献   

10.
Stereotactic radiotherapy is a highly conformal treatment option for intracranial and extracranial malignancies. Stereotactic radiotherapy utilizes specialized equipment specifically designed to avoid normal tissue while delivering ablative treatments with submillimeter precision and accuracy. Linear accelerator based stereotactic radiotherapy incorporates on‐board image guidance utilizing cone beam computed tomography (CT). Many institutions lack the ability to provide image guidance with cone beam CT but delivery of highly conformal treatments with submillimeter precision and accuracy is still feasible. The purpose of this retrospective, pilot study was to describe clinical outcomes for a group of dogs with neurological disease that were treated with an stereotactic radiotherapy technique utilizing intensity modulated radiation therapy, megavoltage computed portal radiography, a bite plate, thermoplastic mold, and mask based positioning system. Twelve dogs with neurological clinical signs were included. The diagnosis of intracranial tumor was made based on advanced imaging (12/12) and confirmed via histopathology (3/12). Twelve courses of stereotactic radiotherapy, utilizing three fractions of 8.0 Gy, were delivered on alternating days. Self‐resolving neurological deterioration was observed in two patients during stereotactic radiotherapy. Neurological progression free interval and median survival time were 273 days (range: 16–692 days) and 361 days (range: 25–862 days). Stereotactic radiotherapy using computed portal radiography may be a safe treatment option for dogs with intracranial tumors.  相似文献   

11.
Our objective was to evaluate possible differences in the number of glomeruli and length of renal biopsies collected in canine subjects by two different types of biopsy needles: a semiautomatic 18-gauge Trucut and an automated 18-gauge Jamshidi modified (Biopince). One hundred biopsy samples obtained from dogs of different ages and gender affected by different nephropathies were evaluated retrospectively. All animals were biopsied using one of the two different needles. Biopsies were performed under ultrasound guidance and evaluated by a single pathologist. Statistical analysis was performed to evaluate possible differences in the number of glomeruli and length of renal biopsies collected comparisons were determined between subgroups of dogs with or without the identification of renal interstitial infiltrates and/or fibrosis. Neither the mean difference of the number of glomeruli nor the length of tissue sample collected with the different needles was significantly different. Likewise, the average biopsy length did not differ in dogs with or without renal interstitial infiltrate in animals biopsied with either biopsy needle. Both the Biopince and the Trucut devices provide diagnostically adequate biopsy renal specimens using ultrasound-guidance.  相似文献   

12.

Background

Deep brain stimulation (DBS) together with concurrent EEG recording has shown promise in the treatment of epilepsy. A novel device is capable of combining these 2 functions and may prove valuable in the treatment of epilepsy in dogs. However, stereotactic implantation of electrodes in dogs has not yet been evaluated.

Objective

To evaluate the feasibility and safety of implanting stimulating and recording electrodes in the brain of normal dogs using the Brainsight system and to evaluate the function of a novel DBS and recording device.

Animals

Four male intact Greyhounds, confirmed to be normal by clinical and neurologic examinations and hematology and biochemistry testing.

Methods

MRI imaging of the brain was performed after attachment of fiducial markers. MRI scans were used to calculate trajectories for electrode placement in the thalamus and hippocampus, which was performed via burr hole craniotomy. Postoperative CT scanning was performed to evaluate electrode location and accuracy of placement was calculated. Serial neurologic examinations were performed to evaluate neurologic deficits and EEG recordings obtained to evaluate the effects of stimulation.

Results

Electrodes were successfully placed in 3 of 4 dogs with a mean accuracy of 4.6 ± 1.5 mm. EEG recordings showed evoked potentials in response to stimulation with a circadian variation in time‐to‐maximal amplitude. No neurologic deficits were seen in any dog.

Conclusions and Clinical Importance

Stereotactic placement of electrodes is safe and feasible in the dog. The development of a novel device capable of providing simultaneous neurostimulation and EEG recording potentially represents a major advance in the treatment of epilepsy.  相似文献   

13.
An accurate method for guiding injections into the canine hip would facilitate diagnostic localization of lameness and targeted treatments. Ultrasound‐guided hip injections are commonly used in humans and large animals. Aims of this prospective study were to describe ultrasound (US) anatomy of the adult canine hip and determine the feasibility and accuracy of intra‐articular placement of injectate using US‐guidance. Seven adult dogs were used to describe US anatomy, five dog cadavers were used to assess the feasibility of the injection technique and 11 dog cadavers were used to assess accuracy of injections. For the accuracy test, 22 joints were injected with iodinated contrast medium by three operators with different experience. With dogs in lateral recumbency, the hyperechoic femoral head surface was identified by following the femoral neck from the greater trochanter or the acetabular rim was localized by following caudally the ilium from the iliac wing.  An anechoic gap between the femoral head and acetabular surface represented the joint. The capsule was visible as a triangular echoic structure and the femoral head articular cartilage appeared as an anechoic band. The needle was inserted axial to the greater trochanter and directed in a dorsolateral–ventromedial direction toward the joint space and then pushed through the capsule. Based on postinjection radiography, accuracy was 81.8% at first attempt and 100% at second attempt. This study indicated that US‐guided injection is a feasible and accurate technique for injecting the adult canine hip. Future studies in live dogs are needed to assess safety and efficacy.  相似文献   

14.
Forty-eight fine-needle aspiration biopsy specimens of intrathoracic lesions were obtained with a Westcott needle by localizing needle placement using TV-monitored, image-amplified fluoroscopy and by detecting changes in tactile sensation. Thiryt-five lesions were pulmonary in origin and 13 were within the mediastinum. Most biospy specimens were obtained with the patients sedated, however, general anesthesia was used in one patient to prevent movement that could have resulted in puncture of a critical structure. The only clinical and radiographic complication from this procedure was pneumothorax, occurring in eight dogs and resulting in one death. Definitive diagnoses were made from tissue obtained from 37 of the 48 lesions sampled for a sensitivity rate of 77.1%. Fine-needle aspiration biopsy was found to be a simple, safe, and accurate diagnostic technique.  相似文献   

15.
16.
Stereotactic radiosurgery (SRS) is a procedure that delivers a single large radiation dose to a well‐defined target. Here, we describe a frameless SRS technique suitable for intracranial targets in canines. Medical records of dogs diagnosed with a primary intracranial tumour by imaging or histopathology that underwent SRS were retrospectively reviewed. Frameless SRS was used successfully to treat tumours in 51 dogs with a variety of head sizes and shapes. Tumours diagnosed included 38 meningiomas, 4 pituitary tumours, 4 trigeminal nerve tumours, 3 gliomas, 1 histiocytic sarcoma and 1 choroid plexus tumour. Median survival time was 399 days for all tumours and for dogs with meningiomas; cause‐specific survival was 493 days for both cohorts. Acute grade III central nervous system toxicity (altered mentation) occurred in two dogs. Frameless SRS resulted in survival times comparable to conventional radiation therapy, but with fewer acute adverse effects and only a single anaesthetic episode required for therapy.  相似文献   

17.
The standard technique for placing a needle into the canine lumbar subarachnoid space is primarily based on palpation of anatomic landmarks and use of probing movements of the needle, however, this technique can be challenging for novice operators. The aim of the current observational, prospective, ex vivo, feasibility study was to compare ultrasound‐guided vs. standard anatomic landmark approaches for novices performing needle placement into the lumbar subarachnoid space using dog cadavers. Eight experienced operators validated the canine cadaver model as usable for training landmark and ultrasound‐guided needle placement into the lumbar subarachnoid space based on realistic anatomy and tissue consistency. With informed consent, 67 final year veterinary students were prospectively enrolled in the study. Students had no prior experience in needle placement into the lumbar subarachnoid space or use of ultrasound. Each student received a short theoretical training about each technique before the trial and then attempted blind landmark‐guided and ultrasound‐guided techniques on randomized canine cadavers. After having performed both procedures, the operators completed a self‐evaluation questionnaire about their performance and self‐confidence. Total success rates for students were 48% and 77% for the landmark‐ and ultrasound‐guided techniques, respectively. Ultrasound guidance significantly increased total success rate when compared to the landmark‐guided technique and significantly reduced the number of attempts. With ultrasound guidance self‐confidence was improved, without bringing any significant change in duration of the needle placement procedure. Findings indicated that use of ultrasound guidance and cadavers are feasible methods for training novice operators in needle placement into the canine lumbar subarachnoid space.  相似文献   

18.
OBJECTIVE: To compare morphologic diagnoses determined from needle biopsy specimens obtained from the livers of dogs and cats with morphologic diagnoses determined from wedge biopsy specimens. DESIGN: Prospective study. ANIMALS: 124 dogs and cats. PROCEDURE: 2 needle biopsy specimens were obtained from each animal; wedge biopsy specimens were obtained from the same liver lobe during laparotomy or postmortem examination. Histologic features were scored independently by 3 individuals; a morphologic diagnosis was rendered after histologic features were scored. Cases were included only if at least 2 of the 3 examiners agreed on the morphologic diagnosis; the definitive diagnosis was considered to be the morphologic diagnosis rendered for the wedge biopsy specimen. Physical characteristics (length, width, surface area, degree of fragmentation, and number of portal triads for needle biopsy specimens and surface area for wedge biopsy specimens) were determined. RESULTS: Definitive diagnoses included hepatic necrosis (n = 10), cholangitis-cholangiohepatitis (13), chronic hepatitis-cirrhosis (12), canine vacuolar hepatopathy (11), portosystemic vascular anomaly-microvascular dysplasia (17), neoplasia (10), miscellaneous hepatic disorders (18), and no hepatic disease (33). For individual examiners, the morphologic diagnosis assigned to needle biopsy specimens agreed with the morphologic diagnosis assigned to wedge biopsy specimens for 56 and 67% of the specimens. All 3 examiners agreed on the morphologic diagnosis assigned to needle and wedge biopsy specimens for 44 and 65% of the specimens, respectively. Morphologic diagnoses assigned to needle biopsy specimens concurred with the definitive diagnosis for 59 of 124 (48%) animals. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that needle biopsy specimens of the liver from dogs and cats must be interpreted with caution.  相似文献   

19.
Cytological smears and histological sections collected from histologically diagnosed cases of thymoma in nine dogs and four cats were reviewed. Most of the histological features were apparent in the cytological specimens with two notable differences. The epithelial component was underestimated and Hassal's corpuscles were not observed using Wright's-stained cytological preparations. Features of thymoma were recognized in seven of the nine cases in which fine needle aspiration biopsy was done. Therefore, cytology, and specifically fine needle aspiration biopsy, has the potential to be a useful aid in the rapid diagnosis of canine and feline thymomas.  相似文献   

20.
Precise localization of the needle tip during CT-guided percutaneous biopsy is considered to be a key element of a successful procedure. To ensure accuracy, the true needle tip must be differentiated from a false or simulated tip which appears when the CT slice encompasses only the shaft of an angled needle. By obtaining images of an aspiration biopsy needle inserted vertically into a phantom and then incrementally tilting the gantry, the authors were able to compare the characteristic features of the true tip to the simulated tip. The true tip was abrupt and distinct and had an adjacent flame-like low density artifact. The simulated tip was indistinct and tapered, yet still produced the adjacent artifact. We concluded that the shape and distinctness of the end portion of the needle itself, rather than the attendant artifact, were the most reliable criteria for accurate needle tip identification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号