首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Renal nuclear medicine is used to evaluate renal function and morphology. Renal scintigraphy is the best imaging modality for evaluation of functional parameters such as glomerular filtration rate and effective renal plasma flow. The commonly used renal radiopharmaceuticals are reviewed. Both imaging and non-imaging techniques are presented. Specific applications of renal nuclear medicine are discussed.  相似文献   

2.
Thyroid imaging using technetium-99m as pertechnetate (99mTcO4) was carried out in five healthy, euthyroid and 37 hyperthyroid cats using both pinhole and parallel-hole collimators. Images of greater resolution, necessary to distinguish bilateral lobe involvement, were obtained using the pinhole collimator. Per cent thyriod 99mTcO4 - uptake was calculated in each cat and was significanly (P < 0.001) higher in hyperthyroid compared with euthyroid cats. In the hyperthyroid cats, per cent thyroid uptake was significantly correlated with serum total thyroxine (T4) and triiodothyronine (T3) Concentrations. Per cent thyroid 99mTcO4 - uptake is increased in feline hyperthyrodism and may be calculated using a pinhole collimator alone at the time of qalitative assessment of the extent of thyroid tissue involvement.  相似文献   

3.
Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two 99mTc‐labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers—ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)—are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with 99mTc‐ECD and followed by 99mTc‐HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T‐test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable.  相似文献   

4.
Quantitative thyroid scintigraphy using pertechnetate was performed in 43 cats with various T4 concentrations and compared to eight normal control cats. Quantitative parameters included percentage dose uptake of the radioisotope by the thyroid, thyroid:salivary ratio and rate of thyroid uptake. All cats were anesthetized for the scan, and images were obtained using both low-energy all purpose (LEAP) and pinhole collimators. All quantitative parameters were significantly correlated to the serum T4 concentration, but the best correlation was obtained using the 20-minute thyroid:salivary ratio using only the most intense of the two thyroid lobes. The thyroid:salivary ratio was a good predictor of the metabolic status of the thyroid.  相似文献   

5.
Bone scintigraphy is often used in horses because of its sensitivity and noninvasive nature. A 99mTc labeled radiopharmaceutical is injected at a dose of between 5.7 and 7.3GBq. Images are acquired immediately postinjection and 2-4h post. People are often in the room with the horse during the acquisition process. Objectives of this study were to (a) document the radiation exposure rates at different distances from various sites of the horse at varying times post injection and (b) study the usefulness of wearing lead aprons to reduce exposure rates to personnel. Radiation exposure rates were measured in at three distances (at skin surface and at 30 and 100 cm from the skin) from three sites (shoulder, thorax, and pelvis) in 19 horses. Exposure rates were measured with and without shielding by a 0.5-mm lead equivalent apron during both the pool and delayed phases. A 0.5mm equivalent lead apron significantly decreases radiation exposure (P<0.05) at these three distances from the three sites during both image acquisition phases. Mean dose reduction factors from the lead apron range from 3.6 to 5.7.  相似文献   

6.
A 14-year-old thoroughbred gelding was presented for the evaluation of acute abdominal pain. Rectally, there was a soft fluctuant painful swelling dorsal to the bladder and to the right of the midline. The creatinine concentration of the peritoneal fluid was 15 mg/dl. Transrectal ultrasonographic examination of the urinary tract revealed a large collection of fluid dissecting from the pelvic portion of the right ureter ventrally through the right side of the bladder wall and into the retroperitoneal space, and a thickened right ureter and bladder wall at the level of the trigone. Cystoscopically there was moderate hemorrhage within the wall of the bladder. Ultrasonography revealed air within the retroperitoneal fluid collection after ureteral catheterization, confirming the preliminary diagnosis of a tear in the right ureter. The gelding was treated medically. After 48 h of hospitalization, nuclear scintigraphy revealed normal clearance from both kidneys and no apparent leakage from the right ureter. The ureteral tear and urinoma were monitored using transrectal ultrasound until resolution. The horse was successfully returned to racing. This case establishes the value of diagngstic ultrasound in the diagnosis and monitoring of a traumatic ureteral tear in a horse.  相似文献   

7.
Disorders of the stifle are a common cause of lameness in horses yet the accuracy of scintigraphy for diagnosis of stifle conditions is controversial. The aim of retrospective cross‐sectional study was to determine the diagnostic sensitivity (Se) of bone scintigraphy in detecting stifle disease and to determine if two orthogonal scintigraphic images improve diagnostic Se. Horses that underwent scintigraphic examination during a two‐year period were included. Horses were divided into two groups: group 1 (N = 23) had lameness that was localized to the stifle by intra‐articular analgesia and group 2 (N = 182) had lameness that was localized to a different location. Scintigraphic studies (one image or two images) were independently and retrospectively analyzed by two radiologists (R1 and R2). Sensitivity, specificity (Sp) and predictive values (PV), and were calculated for each type of study (one image or two images) and for each radiologist (R1 or R2). The Se to detect stifle disorders varied between radiologists (29.2% and 20.8%). The Sp was 84.5% and 88.3%. When two images were evaluated a decrease in the positive PV for both readers occurred. The Cohen kappa coefficient (κ) between readers was poor when one image (0.084) or two images (0.117) were evaluated. Findings from this study indicated that bone‐phase nuclear scintigraphy is reasonably specific but highly insensitive for detecting lameness originating from the stifle in a diverse population of both normal and affected horses. The addition of a caudal scintigraphic image acquisition did not improve diagnostic sensitivity.  相似文献   

8.
A neonatal lamb was admitted with icterus, hypoglycemia, increased liver enzyme activities, and delayed sulfobromophthalein clearance. Biliary and pancreatic duct atresia were documented in this lamb at necropsy. Hepatobiliary scintigraphy was useful in reaching an antemortem diagnosis of bile duct obstruction. Hepatobiliary scintigraphy, using 1.5 mCi of 99m technetium-labeled acid, was performed on the affected lamb and on an age-matched control lamb. Using a large field-of-view camera equipped with a low-energy parallel-hole collimator, right ventral oblique images of the thorax and abdomen were obtained. Images were simultaneously recorded on microdot film by use of a dedicated nuclear medicine computer. In the control lamb, there was rapid clearance of radioactivity from the blood pool, coincident with obvious accumulation of radioactivity in the liver and followed by sequential accumulation in the intrahepatic biliary system, gallbladder, common bile duct, and small intestine. Results of the study in the affected lamb were characterized by prolonged blood-pool radioactivity without appreciable hepatic uptake and by excessive renal and urinary bladder activity in the later phases of the study. Hepatobiliary scintigraphy was a safe and non-invasive procedure that provided quantitative information about the degree of bile duct obstruction in the affected lamb.  相似文献   

9.
With the recent advances in diagnostic imaging technology, cancer imaging in veterinary medicine has become more specific for disease diagnosis, more accurate for determining tumour margins and more sensitive for detecting metastatic disease. Ultrasound provides highly detailed images of parenchymal masses and infiltrative lesions while providing a means for aspiration or biopsy using real‐time image guidance. Computed tomography and magnetic resonance‐imaging techniques provide exquisite anatomical resolution that improves diagnostic accuracy, provides an accurate means of radiation or surgical treatment planning and a quantitative means for monitoring response to therapy. In addition to traditional anatomic imaging, new techniques are being developed for estimating functional parameters such as tumour perfusion, cell metabolism and gene expression. While conventional planar scintigraphy has been available for some time, newer nuclear imaging modalities such as positron emission tomography promise to further improve the accuracy of initial tumour diagnosis and staging and determination of response to therapy. Although many of these functional techniques are not yet clinically available, it is highly likely that some will be integrated into routine clinical practice in the near future.  相似文献   

10.
11.
Radiography has a limited role in the evaluation of the kidneys in foals and adult horses. Ultrasonography is the current method of choice for structural evaluation of the kidneys in horses as it provides additional information to standard serum chemistry and urinalysis evaluation. A variety of structural abnormalities have been identified in diseased equine kidneys with the use of ultrasound. Ultrasound guided renal biopsy is the preferred method for performing renal biopsy in the horse. The use of Duplex Doppler ultrasound may allow for the characterization of regional hemodynamics of the equine kidneys, but is currently an untapped method for evaluation of equine renal hemodynamics.
Radionuclide methods including scintigraphy and quantitative renal function measurement can be used to provide further information about equine renal function. Scintigraphy can provide structural and possibly functional information. Quantitative methods using radiopharmaceuticals can provide precise measurement of glomerular filtration rate and effective renal blood flow. This method is especially helpful in identifying acute renal failure and in guiding response to treatment.
All equine renal imaging techniques should be a supplement to the physical examination and standard laboratory tests. Additional diagnostic aids such as urinary tract endoscopy should also be considered in horses with hematuria, hydroureter, and suspected calculi. Taken together, all these modalities provide a through evaluation of the equine renal system and provide a basis for the clinician to select treatment options and provide prognostic information to the owner.  相似文献   

12.
99mTechnetium methylene diphosphonate (99mTc-MDP) scintigraphy was performed in 14 dogs of different breeds after clinical lameness examination, radiography and synovial fluid analysis failed to localise lameness to a specific area of pain. The scintigraphic protocol included an intravenous injection of 17 MBq 99mTc-MDP/kg bodyweight and vascular, soft tissue and bone phase scans in standardised positions with a low-energy all-purpose collimator. Confirmation of diagnosis was achieved in nine dogs by arthroscopy, repeated lesion-orientated radiography, computed tomography and response to treatment. In seven cases, bone phase scans showed single elbow uptakes, in two cases unilateral limb uptake, and in one case each a single shoulder and tibia uptake; in three cases there was no increased uptake. Vascular and soft tissue phase images did not reveal additional information. Diagnosis of humeral condyle fissures, a fragmented medial coronoid process, panosteitis and arthropathy was possible in nine cases. Skeletal pathology was ruled out in three normal scintigrams. In two dogs with unilateral uptake of multiple joints, no diagnostic benefit was gained from scintigraphy. The highly sensitive and relatively specific uptake allowed localisation and characterisation or exclusion of skeletal lesions in most dogs.  相似文献   

13.
Reasons for performing study: Increased radio‐isotope uptake (IRU) in the subchondral bone of the plantaro‐lateral condyle of the third metatarsus (MTIII) is a commonly reported scintigraphic finding and potential cause of lameness in UK Thoroughbred racehorses in training and has not been fully documented. Objectives: To characterise lameness attributable to IRU of the subchondral bone of MTIII, compare the scintigraphic findings of these horses with a normal population and evaluate the use of scintigraphy as an indicator of prognosis. Hypothesis: IRU will be in significantly higher in horses with subchondral bone injury and will be related to prognosis and future racing performance. Methods: Data were analysed from 48 horses in which subchondral bone injury of the plantaro‐lateral condyle of MTIII had been diagnosed using nuclear scintigraphy and that met the inclusion criteria. Data recorded included age, sex, trainer, racing discipline, lameness assessment, treatment regimes, radiographic and scintigraphic findings, response to diagnostic analgesia where performed and racing performance pre‐ and post diagnosis. Region of interest (ROI) counts were obtained for the plantar condyle and the mid diaphysis from the latero‐medial view, the ratio calculated and then compared with a control group of clinically unaffected horses. Results: The mean condyle mid‐diaphysis ROI ratio was significantly (P<0.001) higher in the affected population and with positively correlation (P = 0.024) with the level of lameness. The presence of radiographic findings had no significant effect on the ROI ratio. Conclusion: Subchondral bone injury of the plantar lateral condyles of MTIII is a significant cause of lameness in UK Thoroughbred racehorses. Nuclear scintigraphy is a useful diagnostic imaging modality in the detection of affected horses but is a poor indicator of prognosis for the condition. Potential relevance: Better understanding of the clinical manifestations, diagnosis of and prognosis for subchondral bone injury will benefit the Thoroughbred industry in the UK.  相似文献   

14.
This retrospective, methods comparison study aimed to compare skeletal scintigraphy and 18F-NaF positron emission tomography (PET) for the detection of abnormalities in the fetlocks of Thoroughbred racehorses. Thirty-three horses (72 limbs) imaged with both scintigraphy and 18F-NaF PET, for investigation of lameness or poor performance related to the fetlock, were included. Seven observers, including experienced racetrack practitioners, surgery and imaging residents, and a board-certified veterinary radiologist, independently reviewed all data for evidence of increased radiopharmaceutical uptake in 10 different regions of interest. The interobserver agreement was higher for PET (Kappa-weighted (K-w) 0.73 (0.51–0.84)) (median (range)) than for scintigraphy (0.61 (0.40–0.77)) (P < 0.0001). When scintigraphy and PET were compared, the agreement was fair (K-w 0.29). More sites of increased uptake were identified using PET compared with scintigraphy. Agreement between the two modalities was higher for the palmar/plantar metacarpal/metatarsal condylar regions (K-w 0.59) than for the proximal sesamoid bones (K-w 0.25). Increased radiopharmaceutical uptake was detected in the medial proximal sesamoid bone in 6.9% and 22.2% of limbs with scintigraphy and PET, respectively. The high interobserver agreement for PET, despite the recent introduction of this technique, demonstrates the ease of clinical interpretation of PET scans. The higher number of lesions detected with PET compared with scintigraphy can be explained by the higher spatial resolution and cross-sectional nature of this modality. Study findings supported using PET in a clinical population of racehorses, in particular for the assessment of the proximal sesamoid bones.  相似文献   

15.
No case series exists in the literature describing scapula stress fractures. The purpose of this study was to review the clinical findings, diagnostic images and outcome of 8 horses diagnosed with scapula stress fractures. Scapula stress fractures were seen in Thoroughbred racehorses displaying acute moderate forelimb lameness. Nuclear scintigraphy identified the mid‐distal scapula spine and/or scapula supraspinous fossa as predilection sites. Conservative management resulted in a good prognosis for return to racing, but stress fracture recurrence may be seen.  相似文献   

16.
We evaluated transplenic injection of iodinated contrast medium for computed tomography (CT) assessment of the portal vasculature. Specific aims were to: (1) establish a protocol for transplenic transplenic CT portography using a 40-row multidetector scanner; (2) compare transplenic CT portography to dual-phase CT angiography in terms of image quality, opacification of the portal system, and contrast enhancement of the portal vasculature and liver; (3) compare personnel exposure during transplenic CT portography and transplenic portal scintigraphy. Seven juvenile dogs underwent transplenic portal scintigraphy, CT angiography, and transplenic CT portography. Transplenic portal scintigraphy and CT angiography were performed using previously established protocols. For transplenic CT portography, a 20- or 22 gauge needle attached to an extension set was placed into the splenic parenchyma using CT guidance. Iodinated contrast medium (175 mg I/ml) was administered, and CT acquisition was started at the time of the injection. Transplenic CT portography was simple, rapid and provided more intense enhancement of the splenic and portal veins, with a lower contrast medium dose (median dose: 525 mg I for transplenic CT portography, 7700 mg I for CT angiography), but caused inconsistent intrahepatic portal branches and parenchymal opacification due to streamlining and streak artifacts. Despite significantly lower attenuation values in the portal vein, CT angiography provided sufficient enhancement for vessel identification and more consistent parenchymal hepatic enhancement. Personnel radiation exposure rate was higher during transplenic CT portography (0.0725 mSv/min) compared with transplenic portal scintigraphy (0.000125 mSv/min). As transplenic CT portography requires an average injection time of 1 min per study; over 650 [corrected] studies must be performed before reaching the maximum permissible whole body dose of 0.05 [corrected] Sv.  相似文献   

17.
Osteolytic appendicular skeletal lesions in eight-stranded, cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii) were evaluated using radiography and skeletal scintigraphy. Radiographic studies were performed monthly in most animals. Follow-up scintigraphy was performed 45-120 days after the initial exams in six turtles. Radiographically, lesions slowly progressed from an early osteolytic process contained to either the proximal or distal end of long bones, to a later stage characterized by thickening of the affected bone, sclerosis, and remodeling of the lesion borders. In seven turtles, the initial scintigrams were characterized by at least one focus of abnormal radiopharmaceutical uptake that correlated with a lytic site noted in radiographs. In five turtles, scintigraphic lesions were characterized by asymmetric radiopharmaceutical uptake rather than by increased intensity of uptake. Scintigraphic studies obtained more than 4 months after the appearance of clinical and radiographic signs had minimal, if any, abnormal radiopharmaceutical uptake, despite the persistence of abnormal radiographic findings. Skeletal scintigraphy is an effective method for more precisely determining if and when these animals can be returned to the wild. Animals were released if normal radiopharmaceutical uptake was seen during initial examination, or if decreased uptake was noted between serial examinations. In four of the turtles, resolution of abnormal scintigraphic findings permitted an objective decision to discontinue antibiotic and antifungal therapy. Seven of the eight turtles were released after correlation of the clinical signs with the imaging findings. Radiographs, however, are still needed to facilitate the correct identification of lesions with scintigraphy.  相似文献   

18.
An ornamental pet fish was diagnosed with a spinal fracture and subluxation involving truncal vertebrae 5 and 6 (T5-T6) using conventional radiography, nuclear scintigraphy, and computed tomography. Attempts to evaluate the dynamic nature of the lesion using conventional fluoroscopy in the unanesthetized, moving patient were unsuccessful. Adaptation of imaging techniques to accommodate a fish patient was not difficult and diagnostic images were obtained. The use of multiple imaging techniques was useful in the diagnosis and determination of the treatment plan of the spinal fracture in this patient.  相似文献   

19.
Stress fracture of the scapula in two horses is described. Both horses had a history of acute lameness after strenuous exercise. Using elective nuclear scintigraphy focal increased radiopharmaceutical uptake in the affected scapula consistent with a fracture was identified. Standing radiography was nondiagnostic in both horses. Ultrasonographic findings in one horse were consistent with a minimally displaced incomplete fracture. Both horses were treated conservatively and returned to train and race successfully postinjury. Veterinary  相似文献   

20.
The construction of ancillary equipment used to improve image quality and reduce personnel radiation exposure in the equine nuclear medicine laboratory is illustrated. The devices include a self supporting lead sheet for shielding the distal limb or limb pair, a hanging lead sheet for shielding the proximal limb, a lead square for shielding the urinary bladder or jugular catheter, a restraining board for acquiring a palmar view of the foot, a head support to stabilize the head for imaging and a head support for stabilizing the neck for imaging. The restraining board and head supports decrease patient motion, improve image quality, and decrease the number of repeat acquisitions so that the time to perform the complete study is shortened. The self supporting shielding device allows the handlers to increase their distance from the horse which enhances radiation safety.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号