首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A dot ELISA for the detection of immunoglobulin M (IgM) antibodies to canine distemper virus (CDC) and canine parvovirus (CPV) was assessed. The titres of IgM antibodies to CDV and CPV in 100 dogs were measured by the Immunocomb ELISA kit and compared with the results derived from the immunofluorescence assay (IFA). There was a strong correlation between the results of the dot ELISA technique and the IFA (P < 0.001). The dot ELISA kit was also used to assess the changes in the levels of immunoglobulin G (IgG) and IgM antibodies to CPV and CDV in 10 puppies vaccinated with a polyvalent vaccine. High levels of IgM antibodies to CPV were first detected seven days after they were vaccinated, and after nine days all the pups had high titres of IgG antibodies to CPV. High levels of IgM antibodies to CDV were detected after nine days and the highest average titres were recorded after 12 days. IgG antibodies to CDV were present from nine days after vaccination.  相似文献   

2.
A dot ELISA was developed for detection of antibodies to Mycobacterium paratuberculosis. The assay was evaluated by testing sera from cattle that were determined, by bacteriologic culturing of feces, to be infected with M paratuberculosis and were suspected of having clinical disease. Further evaluation involved testing sera from cattle in which M paratuberculosis had not been isolated from feces on several attempts. Results of the dot ELISA were positive for sera from 86 of 101 infected cattle, and results were negative for sera from 64 of 64 noninfected cattle. Results of conventional ELISA and agar gel immunodiffusion (AGID) tests were positive for 79 of 99 and for 51 of 101 infected cattle, respectively. The dot ELISA also was evaluated by comparing results of testing 708 sera with results of bacteriologic culturing of matched fecal samples from 262 cattle in 3 central Ohio dairy herds known to include cattle infected with M paratuberculosis. Results of the dot ELISA were positive for 25 of 39 sera from cattle with positive results on culturing of concurrently obtained fecal specimens. The dot ELISA results were negative for 661 of 669 sera from cattle with negative results to culturing of concurrently obtained fecal specimens. The 39 sera from cattle with positive results on bacteriologic culturing of matched fecal specimens had positive results for ELISA and the AGID test 25 and 14 times, respectively. The 669 sera from cattle with concurrently negative results on bacteriologic culturing of feces had negative results to ELISA and the AGID test 559 and 668 times, respectively.  相似文献   

3.
The dot enzyme-linked immunosorbent assay (Dot-ELISA) and the enzyme-linked immunosorbent assay (ELISA) were compared with the immunofluorescent antibody test (IFA) for detection of IgM- and IgG-specific antibodies to human toxoplasmosis. Reciprocal titers were determined in all three assays using sera from 56 patients with suspected toxoplasmosis or with symptoms and diseases requiring exclusion of toxoplasmosis and control sera from 56 healthy persons. Using the Dot-ELISA, six patient sera (10.7%) were positive at titers of greater than equal to 1024 for IgM antibodies (titer range 1024-16 384) and 47 sera (84%) were positive for IgG antibodies (titer range 16-262 144) at a titer of greater than or equal to 16. One control serum was reactive for IgM (titer 1024) and 10 control sera (18%) were positive for IgG in the Dot-ELISA. In the ELISA, at titers of greater than or equal to 128, five sera (9%) were reactive for IgM (titer range 128-512) and 52 sera (92.8%) were reactive for IgG (titer range 32-8192) at a titer of greater than or equal to 32; no control sera gave positive reactions for IgM while 10 sera (18%) were positive for IgG in the ELISA. Using the IFA test at reciprocal titers of greater than or equal to 16, four sera (7.1%) were positive for IgM (titer range 32-512), and 51 sera (91%) were positive for IgG (titer range 16-8192). None was reactive for IgM, and eight sera (14%) were positive for IgG (titer range 32-128) in the IFA test. The Dot-ELISA correlated well with the IFA test (correlation coefficient = 0.895) and the ELISA correlated slightly higher with the IFA test (correlation coefficient = 0.910) for detection of IgG antibodies to Toxoplasma gondii.  相似文献   

4.
A rapid, simple and inexpensive dot immunobinding assay (DIA) was evaluated for the serodiagnosis of paratuberculosis in cattle. The assay was performed on nitrocellulose strips which were dotted with purified protoplasmic antigen of Mycobacterium paratuberculosis. After incubation with test serum samples, the bound antibodies were detected using an enzyme-amplified immunostaining procedure. The efficacy of DIA as a screening test for paratuberculosis was compared to that of an enzyme-linked immunosorbent assay (ELISA), a modified agar gel immunodiffusion (mAGID) test, and an AGID test using 329 serum samples from cattle which were examined for M. paratuberculosis infection by a sensitive fecal culture technique. The DIA and ELISA had comparable results and both of the enzyme immunoassays had higher sensitivity than tests based on AGID. The sensitivity of all four tests was influenced by the intensity of fecal bacterial shedding. Preabsorption of sera with Mycobacterium phlei increased the sensitivity of both enzyme immunoassays. the specificity but reduced the sensitivity of both enzyme immunoassays.  相似文献   

5.
Several enzyme-linked immunosorbent assays (ELISAs) have been developed for the detection of antibodies to Corynebacterium pseudotuberculosis, the causative agent of caseous lymphadenitis (CLA). However, none are commercially available in the UK. It was therefore necessary to develop a new, economic ELISA for use in a research project studying the epidemiology of CLA in UK sheep. The ELISA with its diagnostic qualities is presented. The ELISA was developed using sonicated C. pseudotuberculosis and optimised to detect total antibody or IgG class antibody in serum. Receiver operating characteristic (ROC) curves were obtained and the area under the ROC curve was used to compare the sensitivity and specificity of the two ELISAs. Both versions of the ELISA were evaluated on a panel of 150 positive reference sera and 103 negative reference sera. Using the test at 100% specificity, the sensitivity of detection of total antibody was 71% (95% confidence interval 63-78%), and the sensitivity of detection of IgG antibody to C. pseudotuberculosis was 83% (76-89%), which compares favourably with other reported ELISA tests for CLA in sheep. The sensitivity of the IgG antibody assay may be higher because of the greater affinity of IgG class antibodies compared with the IgM antibodies also detected by the total antibody ELISA. The results of ROC analysis indicated that the IgG isotype ELISA was more accurate than the total antibody ELISA. The efficiency of the test was greatest when serum samples were run in a dilution series than when any single serum dilution was used. The ELISA is considered to be suitable for application in field studies of CLA in UK sheep.  相似文献   

6.
Three monoclonal antibodies, specific for porcine IgG, IgM and IgA, were used to develop isotype-specific immunoperoxidase monolayer assays for the detection of antibodies against African swine fever virus. A mixture of anti-IgM and anti-IgG monoclonal antibodies was used in an assay designed for screening sera. This test was compared with a commercially available ELISA by using experimental sera and field sera obtained after an outbreak of African swine fever on two farms in the Netherlands in 1986. Although the ELISA was less sensitive than the immunoperoxidase monolayer assay on sera taken early after infection, the tests were equally useful for screening purposes. The isotype-specific assays gave epizootiological information about the stage of infection on the two farms.  相似文献   

7.
The "gold standard" for the detection of antibodies to Ehrlichia canis, the cause of canine monocytic ehrlichiosis (CME), is the indirect immunofluorescence antibody (IFA) test. The IFA test however is generally available only in selected laboratories and requires extensive equipment and trained personnel. A double-blind study was conducted to compare the ability of an in-clinic standardized enzyme-linked immunosorbent assay (ELISA) test kit to measure E. canis IgG antibodies in dogs compared with the standard IFA technique. A good correlation was found between the 2 techniques (r2 = 0.8793; P < 0.0001). Evidence for the sensitivity of the ELISA technique for the early detection of E. canis IgG antibodies was demonstrated by comparing the appearance of E. canis antibody titers by the IFA and ELISA techniques after artificial infection of 2 sets of dogs. In both experimental infections, both tests were equally sensitive for the early detection of IgG antibodies against E. canis, and the results correlated well with the appearance of fever and clinical signs. Proposed application of the in-clinic ELISA test is to aid in the diagnosis of CME.  相似文献   

8.
More than 300 bovine sera from a previously reported vaccination and challenge trial were tested for antibodies to bovine herpesvirus 1 (BHV1) by five serological assays: enzyme-linked immunosorbent assay (ELISA) for IgM and IgG, passive haemagglutination (PHA), and two methods of virus neutralisation (VN). In a statistical comparison of ELISA (IgG), PHA and VN results, the assays showed highly significant correlations (P less than 0.01). The sensitivities of ELISA and 24-hour neutralisation tests were similar, in contrast to passive haemagglutination and one hour neutralisation which failed to detect BHV1 antibodies in some low titre sera.  相似文献   

9.
The enzyme-linked immunosorbent assay (ELISA) was evaluated for use in the quantitative measurement of bovine immunoglobulin IgG1 and IgG2 antibodies. A method for standardization was devised in which IgG1 or IgG2 was directly adsorbed to polystyrene tubes and the actual degree of binding was calculated by using different input amounts of 125I-labeled IgG1 or IgG2. Values for quantity of IgG1 antibodies to human serum albumin were only slightly higher when measured by the ELISA than when measured by quantitative precipitation although the value measured by the ELISA for IgG2 antibodies was twice that determined by quantitative precipitation. This discrepancy could result from conjugate cross reactivity, differences in affinity between antibodies of the 2 subclasses, or the occurrence of IgG2 nonprecipitating antibodies. The danger of overlooking subclass anti-globulin cross reactivity because of the failure to detect it by immunoprecipitation, also is illustrated. In addition, only enzyme-antibody conjugates prepared with specifically purified antibodies were effective, and reproducibility of individual data points required that 4 replicate determinations be performed. Advantages, pitfalls, and limitations of the ELISA are discussed.  相似文献   

10.
Toxoplasma gondii IgG antibodies were measured in 212 goat sera, comparing the Sabin-Feldman dye-test and a three-layer sandwich enzyme-linked immunosorbent assay (ELISA). With 98 % concordance obtained between these 2 tests, the results are at the same paragon as for human sera. Accordingly, the ELISA sandwich procedure appears to be suitable for large-scale analysis of goat sera. The discordant 2 % were ELISA positive and dye-test negative. One possible explanation of the divergent titres is given using an immunized goat model.Key words: Toxoplasma gondii, goat, antibodies, dye-test, ELISA  相似文献   

11.
A total of 384 sheep serum samples collected from two organised sheep farms was tested by dot immunobinding assay (DIA) and indirect enzyme-linked immunosorbent assay (I-ELISA) for the presence of bluetongue virus (BTV) antibodies. The results of both these assays were compared to find a sensitive, specific, rapid, easily performed and economical test for the diagnosis of bluetongue disease. DIA detected BTV antibodies in 210 samples (54.94%) and I-ELISA detected 157 positive samples (40.88%). Competitive ELISA (C-ELISA) was performed to check the discrepancies in I-ELISA and DIA. On the basis of these tests the overall agreement, relative specificity and sensitivity between ELISA and DIA were 75%, 87.6% and 100%, respectively. DIA was found to be a rapid, sensitive, easily performed and economical test as compared to ELISA.  相似文献   

12.
A blocking (B) dot enzyme-linked immunosorbent assay (ELISA), using a monoclonal antibody (mAb) against a group specific antigen of bluetongue virus (BTV) is described for the detection of BTV antibodies to BTV in cattle sera. Dots of BTV antigens were adsorbed to nitrocellulose (NC) strips and/or NC mounted in the windows of dipsticks. After blocking the remaining sites of the NC paper with milk powder solution and immersion in the test sample, the NC strips and dipsticks were exposed to mAb. Bound mAb was detected with peroxidase conjugated anti-mouse IgG (H and L). In the absence of anti-BTV antibody in the test sample, BTV antigen sites were reactive with mAb as indicated by a brown colored dot in the presence of the enzyme substrate, hydrogen peroxide and diaminobenzidine. In the presence of sufficient anti-BTV antibodies no color reaction was observed. The performance of these assays in detecting anti-BTV antibody in field blood eluate samples, prepared from whole blood dried on filter paper, from 395 bluetongue-free cattle in Canada and 635 sentinel cattle in Florida, USA, was evaluated and compared with the standard competitive (C) ELISA. The specificity of the dipstick B-dot ELISA was identical to that of the C-ELISA in testing of BT-free Canadian cattle but not in the testing of samples from the sentinel cattle in Florida, resulting in values of 100% diagnostic and 88.9% relative specificity, respectively. Based on the C-ELISA, the specificity of the NC strip B-dot ELISA was low and in the same order as that of the dipstick assay.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
The dot enzyme-linked immunosorbent assay (Dot-ELISA) was used for the detection of IgG antibodies to Sarcocystis muris and compared with the enzyme-linked immunosorbent assay (ELISA) and the indirect fluorescent antibody test (IFAT). In experimentally infected mice, first positive reactions occurred in the Dot-ELISA between 18 and 32 days after infection (dpi), in the ELISA between 18 and 49 dpi, and in the IFAT between 11 and 25 dpi. Maximum titers were 1:40 960 in the Dot-ELISA, 1:1280 in the ELISA and 1:2560 in the IFAT. High titers persisted until the end of the examination period (182 dpi) in all 3 tests. In immunized mice, all 3 tests detected antibodies 7 days after the first injection of protein antigen. The highest titers of 1:5120 and 1:10 240 were recorded in the Dot-ELISA after 35 days; titers of 1:1280 and 1:2560 were observed in the ELISA, and titers of 1:160 and 1:320 in the IFAT after 42 days. No false-positive reactions occurred in the Dot-ELISA and in the IFAT when 177 sera from non-infected mice were examined, but 1% (2/177) of the sera reacted positively in the ELISA. Sixty-three percent (94/150) of sera from mice infected experimentally with Toxoplasma gondii showed slight positive reactions up to 1:40 in the Dot-ELISA; 9% (13/150) of the sera reacted positively up to 1:40 in the IFAT and 4% (6/150) up to 1:20 in the ELISA. The Dot-ELISA appears to be a good alternative to the ELISA and the IFAT in the serodiagnosis of sarcosporidiosis and should be further evaluated for the serodiagnosis of other parasitic diseases.  相似文献   

14.
Skin hypersensitivities (allergies) in horses are often diagnosed using clinical signs only. Intradermal testing or serological assays are diagnostic options to confirm the allergic nature of the disease and to identify the allergen(s). Our objective was to develop an allergen-specific enzyme-linked immunosorbent assay (ELISA) using a monoclonal antibody specific for horse IgE and to examine its potential for allergen detection in serum in comparison to intradermal testing. Intradermal testing with 61 allergen extracts was performed on 10 horses affected with skin hypersensitivity. Their sera were analyzed by ELISA for IgE antibodies to the same allergens. The kappa test of concordance was used for comparison of the results of both tests. Out of 61 allergen extracts, only two (Timothy and Quack) had kappa values greater than 0.60, suggesting a substantial agreement between skin testing and IgE ELISA. The statistical comparison of the remaining 59 allergens showed little or no concordance between the tests beyond chance. To identify parameters that may influence the sensitivity of the ELISA, the assay was modified to detect allergen-specific IgGb and IgG(T) in serum, and the protein content in all allergen extracts was determined by SDS-PAGE. The commercial allergen extracts revealed a high variation in detectable protein. High concentrations of allergen-specific IgG in horse serum were found to compete with IgE for binding to the plates. In conclusion, an ELISA using whole serum and crude allergen preparations provides limited diagnostic information in horses. The reliable diagnosis of allergens in equine skin hypersensitivity is essential to improve allergen-specific treatments, such as hyposensitization, or the development of allergy vaccines.  相似文献   

15.
Six tests for the detection of West Nile virus (WNV) antibodies in the serum of experimentally infected chickens were compared. The tests included the hemagglutination-inhibition test (HIT), immunoglobulin M (IgM)-capture enzyme-linked immunosorbent assay (ELISA) with WNV-infected mouse brain antigen, immunoglobulin G (IgG) indirect ELISA with tickborne encephalitis viral antigen, the microtitre virus neutralization test, the standard plaque reduction neutralization test (PRNT), and the microtitre PRNT (micro-PRNT). Thirty adult chickens, intravenously and intramuscularly inoculated with 107 plaque-forming units (PFU) of WNV strain Egypt 101, were bled and given a booster of 107 PFU at 7, 15, and 21 d postinoculation; the final blood collection was on day 28. Although the micro-PRNT is capable of detecting the highest antibody titres during both early and late infection, because of the technical complexity and time requirements of this test a combination of IgM and IgG ELISAs is recommended for serologic screening. Serum samples that give positive results in the ELISAs can then be tested by the micro-PRNT to determine the specificity of antibodies to WNV.  相似文献   

16.
A radioimmunoprecipitation assay (RIPA) has been developed for detection of antibody to African swine fever virus (ASFV) and compared with the immunoblot assay with regard to sensitivity and specificity. Two hundred seven field sera, obtained from pigs in Spain from different geographic areas between 1975 and 1986, that were positive by ASFV enzyme-linked immunosorbent assay (ELISA) were also analysed by immunoblot assay and RIPA. By serum dilution experiments, the RIPA appeared at least as sensitive as the ELISA and immunoblotting tests, although ELISA and RIPA detected antibodies to ASFV earlier in natural infection than did the immunoblot assay, as disclosed by animal inoculation studies. The most antigenic ASFV-induced proteins in natural infection detected by RIPA were the viral proteins p243, p172, p73, p25.5, p15, and p12 and the infection proteins p30 and p23.5. In the immunoblot assay, the proteins that were most reactive with the same sera were the viral protein p25.5 and the infection proteins p30, p25, and p21.5. Only 1 serum, from an animal infected with ASFV, was negative by immunoblot assay but showed a positive result by RIPA. A modification of conventional RIPA was performed using a dot transference of immunoprecipitated proteins to a nitrocellulose filter. This modification simplified the conventional RIPA procedures by eliminating the electrophoresis of immunoprecipitated proteins without affecting sensitivity and specificity. The ease of use, specificity, and the sensitivity comparable to that of the immunoblot assay make the RIPA a useful confirmatory assay for sera that yield conflicting results in other ASFV antibody assays.  相似文献   

17.
In the Balkan countries, where trichinellosis is a re-emerging zoonosis, it is of great importance to determine Trichinella infection prevalence among the major hosts, including horses. One method for monitoring prevalence is serological surveillance; however, the validity of serological methods in horses is not well understood. The dynamics of anti-Trichinella IgG production and circulating excretory/secretory (ES) antigens were investigated in three horses experimentally-infected with Trichinella spiralis. Horses were slaughtered at 32 week post infection (p.i.). Low worm burdens were found in all three animals. Anti-Trichinella IgG was detected up to 32 weeks p.i. by an indirect immunofluorescence assay (IFA) and by Western blot (Wb), but not by ELISA. The ELISA test detected antibodies for only a short period of time (up to 18 weeks p.i. using ES antigen or up to 20 weeks p.i. using tyvelose-BSA antigen). The presence of circulating muscle larvae ES antigen in sera of infected horses was observed by dot blot from the 4th week p.i. up to the 32nd week p.i.  相似文献   

18.
Encephalitozoon cuniculi is a small protozoan parasite in the phylum Microspora. It has been shown to naturally infect several host species, including humans. Infection with microsporidia is usually asymptomatic, except in young or immunocompromised hosts. Currently, serological diagnosis of infection is made using the indirect immunofluorescent antibody assay (IFA) or enzyme-linked immunosorbent assay (ELISA). Although these methods are sensitive and reliable, there are several drawbacks to the IFA and ELISA tests. Cross-reactivity between other Encephalitozoon species is common, and specialized equipment is required to conduct these tests. This paper reports the development of a direct agglutination test for detecting IgG antibodies to E. cuniculi. The utility of the agglutination test was examined in CD-1 and C3H/He mice infected with E. cuniculi or one of 2 other Encephalitozoon species. Test sera were incubated overnight with eosin-stained microsporidia spores in round-bottom microtiter plates. In positive samples, agglutination of spores with antibodies in test sera resulted in an opaque mat spread across the well. The results indicate that the agglutination test is 86% sensitive and 98% specific for E. cuniculi, with limited cross-reactivity to Encephalitozoon intestinalis. No cross-reactivity to Encephalitozoon hellem was observed. The test is fast and easy to conduct, and species-specific antibodies are not required.  相似文献   

19.
Enzyme-linked immunosorbent assay (ELISA) was used for detection of immunoglobulin (Ig) M and IgG antibodies against a serologically common antigen (original endotoxin protein), protease, and elastase of Pseudomonas aeruginosa. The P aeruginosa antibody in horse sera was measured, using ELISA. Horseradish peroxidase-labeled rabbit anti-horse IgM and IgG antibodies were used for enzyme-labeled antibody conjugate. 5-Aminosalicylic acid and H2O2 were used for substrate. Sera collected from a vaccinated horse, a newborn foal, and 72 healthy racehorses were investigated for antibodies against P aeruginosa by ELISA and passive hemagglutination procedure. Changes in IgM and IgG antibody titers with vaccination were clear by ELISA. In the newborn foal, significant amounts of IgM and IgG antibodies from colostrum were present on the 1st day after birth. It was shown by ELISA that the level of antibodies in the newborn decreased initially and then increased. Some antibodies against original endotoxin protein, protease, and elastase of P aeruginosa were detected in almost all the healthy racehorses investigated.  相似文献   

20.
A blocking enzyme-linked immunosorbent assay (ELISA) was developed for detecting antibodies against bovine enterovirus (BEV) in bovine sera. In this ELISA, bovine serum samples were allowed to react with captured viral antigens (by specific chicken IgG), before the addition of specific mouse IgG for measuring non-occupied viral epitopes. The ELISA was slightly more sensitive and required a shorter time period than traditional serum neutralisation (SN). Among the 871 bovine serum samples tested so far, the titres produced by this assay had a significant correlation with those recorded by SN. The ELISA could be used as an alternative assay for SN in a large-scale BEV antibody investigation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号