首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats. DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared. RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.  相似文献   

2.
Systemic hypertension is hypothesized to cause renal injury to dogs. This study was performed on dogs with surgically induced renal failure to determine whether hypertension was associated with altered renal function or morphology. Mean arterial pressure (MAP), heart rate (HR), systolic arterial pressure (SAP), and diastolic arterial pressure (DAP) were measured before and after surgery. Glomerular filtration rate (GFR) and urine protein:creatinine ratios (UPC) were measured at 1, 12, 24, 36, and 56-69 weeks after surgery, and renal histology was evaluated terminally. The mean of weekly MAP, SAP, and DAP measurements for each dog over the 1st 26 weeks was used to rank dogs on the basis of MAP, SAP, or DAP values. A statistically significant association was found between systemic arterial pressure ranking and ranked measures of adverse renal responses. When dogs were divided into higher pressure and lower pressure groups on the basis of SAP, group 1 (higher pressure, n = 9) compared with group 2 (lower pressure, n = 10) had significantly lower GFR values at 36 and 56-69 weeks; higher UPC values at 12 and 56-69 weeks; and higher kidney lesion scores for mesangial matrix, tubule damage, and fibrosis. When dogs were divided on MAP and DAP values, group 1 compared with group 2 had significantly lower GFR values at 12, 24, 36, and 56-69 weeks; higher UPC values at 12 and 56-69 weeks; and higher kidney lesion scores for mesangial matrix, tubule damage, fibrosis, and cell infiltrate. These results demonstrate an association between increased systemic arterial pressure and renal injury. Results from this study might apply to dogs with some types of naturally occurring renal failure.  相似文献   

3.
The objective of this paper was to evaluate romifidine as a pre-medicant in dogs prior to propofol-isoflurane anaesthesia, and to compare it with medetomidine. For this, eight healthy dogs were anaesthetised. Each dog received three pre-anaesthetic protocols: R40 (romifidine, 40 microg/kg, IV), R80 (romifidine, 80 microg/kg, IV) or MED (medetomidine, 10 microg/kg, IV). Induction of anaesthesia was delivered with propofol and maintained with isoflurane. The following variables were studied before sedative administration and 10 min after sedative administration: heart rate (HR), mean arterial pressure (MAP), systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) and respiratory rate (RR). During maintenance, the following variables were recorded at 5-min intervals: HR, MAP, SAD, DAP, arterial oxygen saturation (SpO(2)), end-tidal CO(2)(EtCO(2)), end-tidal concentration of isoflurane (EtISO) required for maintenance of anaesthesia and tidal volume (TV). Time to extubation, time to sternal recumbency and time to standing were also registered. HR and RR experimented a significantly decreased during sedation in all protocols respect to baseline values. Mean HR, MAP, SAP, DAP, SpO(2), EtCO(2), and TV during anaesthesia were similar for the three protocols. End tidal of isoflurane concentration was statistically similar for all protocols. Recovery time for R40 was significantly shorter than in R80 and MED. The studied combination of romifidine, propofol and isoflurane appears to be an effective drug combination for inducing and maintaining general anaesthesia in healthy dogs.  相似文献   

4.
BACKGROUND: Collection of 50 mL of blood (standard unit) in cats is a common procedure. There are several studies on the health status of donors, but to our knowledge there are no reports on the effects of blood collection on the feline donor. HYPOTHESIS: Collection of a standard unit of blood from cats does not significantly change arterial blood pressure (BP), mean arterial pressure (MAP), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), PCV, and heart rate (HR) in healthy blood donor cats. ANIMALS: Twenty-six healthy blood donor cats (6 spayed females and 20 castrated males). METHODS: An oscillometric method was used to measure MAP, SAP, DAP, and to quantify HR before and after blood collection; PCV was obtained before and immediately after blood collection. RESULTS: Despite a significant decrease (P < .05) in all variables (ie, BP, PCV, HR) after blood collection, no adverse events were observed. CONCLUSIONS AND CLINICAL IMPORTANCE: The collection of a unit of blood for transfusion from healthy donor cats weighing more than 5 kg appears to be safe, but this procedure leads to a decrease in arterial BP, PCV, and HR.  相似文献   

5.
Cardiovascular effects of topical ophthalmic 10% phenylephrine in dogs   总被引:1,自引:1,他引:0  
Objective To evaluate the effect of topical ophthalmic 10% phenylephrine on systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), pulse rate (PR) and electrocardiogram (ECG) in dogs. Animals studied Nine clinically normal dogs. Procedure Arterial catheters were placed in the dorsal pedal artery of awake dogs and ECG leads were attached. After a 15‐min acclimatization period, baseline PR, SAP, DAP and MAP were recorded every 5 min for 20 min. Two treatment groups (eight dogs each) were studied. Group I: one drop of phenylephrine was placed in each eye once. Group II: one drop of phenylephrine was placed in each eye three times at 5‐min intervals. Following treatment, PR, SAP, DAP and MAP were recorded every 5 min for 90 min. The mixed procedure of the SAS system was used to perform a repeated measures analysis of variance to test for linear and quadratic trends across time. Results Group I: There was a significant quadratic decrease in PR across time (P = 0.0051). Systolic arterial pressure increased linearly with time (P = 0.0002), MAP increased linearly with time (P = 0.0131), and DAP increased linearly with time (P = 0.0001). Group II: There was a significant quadratic decrease in PR across time (P = 0.0023). There was a significant quadratic increase in SAP (P = 0.0324), MAP (P = 0.0103) and DAP (P = 0.0131) across time. Conclusions Topical ophthalmic application of 10% phenylephrine in normal dogs results in elevation of arterial blood pressure and reflex bradycardia.  相似文献   

6.
Objective: To determine the cardiovascular effects of desflurane in dogs following acute hemorrhage. Design: Experimental study. Animals: Eight mix breed dogs. Interventions: Hemorrhage was induced by withdrawal of blood until mean arterial pressure (MAP) dropped to 60 mmHg in conscious dogs. Blood pressure was maintained at 60 mmHg for 1 hour by further removal or replacement of blood. Desflurane was delivered by facemask until endotracheal intubation could be performed and a desflurane expiratory end‐tidal concentration of 10.5 V% was maintained. Measurements and main results: Systolic, diastolic, and mean arterial blood pressure (SAP, DAP and MAP), central venous pressure (CVP), cardiac output (CO), stroke volume (SV), cardiac index (CI), systemic vascular resistance (SVR), heart rate (HR), respiratory rate (RR), partial pressure of carbon dioxide in arterial blood (PaCO2), and arterial pH were recorded before and 60 minutes after hemorrhage, and 5, 15, 30, 45 and 60 minutes after intubation. Sixty minutes after hemorrhage, SAP, DAP, MAP, CVP, CO, CI, SV, PaCO2, and arterial pH decreased, and HR and RR increased when compared with baselines values. Immediately after intubation, MAP and arterial pH decreased, and PaCO2 increased. Fifteen minutes after intubation SAP, DAP, MAP, arterial pH, and SVR decreased. At 30 and 45 minutes, MAP and DAP remained decreased and PaCO2 increased, compared with values measured after hemorrhage. Arterial pH increased after 30 minutes of desflurane administration compared with values measured 5 minutes after intubation. Conclusions: Desflurane induced significant changes in blood pressure and arterial pH when administered to dogs following acute hemorrhage.  相似文献   

7.
OBJECTIVE: To compare the performance of the Surgivet Non-Invasive Blood Pressure (NIBP) monitor V60046 with an invasive blood pressure (IBP) technique in anaesthetized dogs. STUDY DESIGN: A prospective study. ANIMALS: Thirty-four dogs, anaesthetized for a variety of procedures. METHODS: Various anaesthetic protocols were used. Invasive blood pressure measurement was made using a catheter in the femoral or the pedal artery. A cuff was placed on the contralateral limb to allow non invasive measurements. Recordings of arterial blood pressures (ABPs) were taken at simultaneous times for a range of pressures. For analysis, three pressure levels were determined: high [systolic blood pressure (SAP) > 121 mmHg], normal (91 mmHg < SAP < 120 mmHg) and low (SAP < 90 mmHg). Comparisons between invasive and non invasive measurements were made using Bland-Altmann analysis. RESULTS: The NIBP monitor consistently underestimated blood pressure at all levels. The lowest biases and greatest precision were obtained at low and normal pressure levels for SAP and mean arterial pressure (MAP). At low blood pressure levels, the biases +/- 95% confidence interval (CI) were 1.9 +/- 2.96 mmHg (SAP), 8.3 +/- 2.41 mmHg diastolic arterial pressure (DAP) and 3.5 +/- 2.09 mmHg (MAP). At normal blood pressure levels, biases and CI were: 1.2 +/- 2.13 mmHg (SAP), 5.2 +/- 2.32 mmHg (DAP) and 2.1 +/- 1.54 mmHg (MAP). At high blood pressure levels, the biases and CI were 22.7 +/- 5.85 mmHg (SAP), 5.5 +/- 3.13 mmHg (DAP) and 9.4 +/- 3.52 mmHg (MAP). In 90.6% of cases of hypotension (MAP < 70 mmHg), the low blood pressure was correctly diagnosed by the Surgivet. CONCLUSIONS: Measurement of blood pressure with the indirect monitor allowed detection of hypotension using either SAP or MAP. The most accurate readings were determined for MAP at hypotensive and normal levels. The monitor lacked accuracy at high pressures. CLINICAL RELEVANCE: When severe challenges to the cardiovascular system are anticipated, an invasive method of recording ABP is preferable. For routine usage, the Surgivet monitor provided a reliable and safe method of NIBP monitoring in dogs, thereby contributing to the safety of anaesthesia by providing accurate information about the circulation.  相似文献   

8.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

9.
The cardiopulmonary effects of desflurane and sevoflurane anesthesia were compared in cats breathing spontaneously. Heart (HR) and respiratory (RR) rates; systolic (SAP), diastolic (DAP) and mean arterial (MAP) pressures; partial pressure of end tidal carbon dioxide (PETCO2), arterial blood pH (pH), arterial partial pressure of oxygen (PaO2) and carbon dioxide (PaCO2); base deficit (BD), arterial oxygen saturation (SaO2) and bicarbonate ion concentration (HCO3) were measured. Anesthesia was induced with propofol (8+/-2.3mg/kg IV) and maintained with desflurane (GD) or sevoflurane (GS), both at 1.3 MAC. Data were analyzed by analysis of variance (ANOVA), followed by the Tukey test (P<0.05). Both anesthetics showed similar effects. HR and RR decreased when compared to the basal values, but remained constant during inhalant anesthesia and PETCO2 increased with time. Both anesthetics caused acidemia and hypercapnia, but BD stayed within normal limits. Therefore, despite reducing HR and SAP (GD) when compared to the basal values, desflurane and sevoflurane provide good stability of the cardiovascular parameters during a short period of inhalant anesthesia (T20-T60). However, both volatile anesthetics cause acute respiratory acidosis in cats breathing spontaneously.  相似文献   

10.
Oscillometric blood pressure monitoring may be a practical tool for short procedures or those performed outside of the operating room. Oscillometric and direct blood pressure values in 30 juvenile and adult horses in a clinical setting using mixed effect models were compared. The limits of agreement and percentage errors were also calculated. We evaluated the sensitivity and false positive rate for the oscillometric method to trigger an intervention for treating blood pressure [direct mean arterial pressure (MAP) < 70 mmHg]. Oscillometric MAP and diastolic arterial pressure (DAP) differed from direct values (P < 0.001); systolic arterial pressure (SAP) did not (P = 0.08). Wide limits of agreement were observed. Percentage errors were smaller for SAP (39%) than for MAP and DAP (48% and 72%). The oscillometric monitor indicated there was a requirement for blood pressure treatment with a true positive rate of 82%, consequently, it failed 18% of the times. The false positive rate (unnecessary treatment) was 55%.  相似文献   

11.
OBJECTIVE: To compare haemodynamic and respiratory variables during isoflurane-fentanyl (IF) and propofol-fentanyl (PF) anaesthesia for surgery in injured cats. STUDY DESIGN: Prospective, randomized, controlled clinical study. ANIMALS: Thirty-three client-owned injured cats undergoing orthopaedic surgery. MATERIALS AND METHODS: Pre-anaesthetic medication was intravenous midazolam 1 mg kg(-1), butorphanol 0.4 mg kg(-1) and ketamine 2 mg kg(-1). Anaesthesia was induced with propofol (P) and maintained with either: (a) a continuous rate infusion (CRI) of fentanyl (F) 0.02 mg kg(-1) hour(-1) and isoflurane (initial end-tidal concentration of 1%), (b) a fentanyl CRI (dose as before) and sevoflurane (initial end-tidal concentration of 2%) or (c) a CRI of propofol (12 mg kg(-1) hour(-1)). All three techniques were given to effect until surgical anaesthesia was achieved. Heart rate and rhythm (ECG), mean arterial blood pressure, respiratory rate, tidal volume and end-tidal CO(2) concentration were recorded. Venous blood gas analysis was performed before and after sedation, and at the end of anaesthesia. Blood chemistry and blood cell counts were assessed before, at the end of, and 24 hours after anaesthesia. The variables recorded from cats anaesthetized with IF and PF were compared. RESULTS: Mean end-expiratory isoflurane concentration was 1.19 +/- 0.19%. The propofol infusion rate was 11.4 +/- 0.8 mg kg(-1) hour(-1). No significant differences between the two groups in heart rate were identified; no cardiac dysrhythmias were recorded. Mean arterial blood pressure was significantly lower in IF cats during skin incision (p = 0.01), during surgery without intense surgical stimulation (p < 0.01) and during surgery with intense surgical stimulation (p = 0.01). Nine of 11 cats in the IF group were markedly hypotensive (34-49 mmHg) while seven of 11 cats in group PF were mildly hypotensive (49-59 mmHg). One of 11 cats in group IF and nine of 11 cats in group PF required intermittent positive pressure ventilation (IPPV) to maintain end-tidal CO(2) levels below 6.66 kPa (50 mmHg). CONCLUSION AND CLINICAL RELEVANCE: Despite the necessity to ventilate the lungs of cats in the PF group, arterial blood pressure was better maintained. Propofol-fentanyl anaesthesia is better for surgery in injured cats providing the means to impose IPPV are available.  相似文献   

12.
ObjectiveTo evaluate the agreement of two noninvasive blood pressure devices: a human device with the cuff placed on the wrist (Omron R1) and a veterinary device with the cuff placed on the upper brachium (Surgivet Advisor Vital Signs Monitor) with invasive blood pressure (IBP) measurement in anaesthetized chimpanzees.Study designProspective clinical study.AnimalsA convenience sample of 11 adult chimpanzees undergoing anaesthesia for translocation and routine health checks.MethodsSystolic (SAP) and diastolic arterial pressures (DAP) were continuously recorded via a transducer connected to a femoral artery cannula, and at 5 minute intervals from the two oscillometric devices. Agreement was explored using Bland-Altman analysis and bias defined as the mean difference between the two measurement methods. Spearman correlation coefficients were calculated. Significance was set at p < 0.05.ResultsBias and standard deviation for the Surgivet compared with IBP were 8.6 ± 18 for SAP and 8.4 ± 9.9 for DAP, showing a significant underestimation of both variables. Limits of agreement (LOA) were from –27 to 44 for SAP and from –11 to 28 for DAP. Correlation coefficients between the Surgivet and IBP values were 0.86 for SAP and 0.85 for DAP (p < 0.0001). Bias and standard deviation for the Omron compared with the IBP were –21 ± 25 for SAP and –18 ± 15 for DAP, showing a significant overestimation of both variables. LOA were from –70 to –28 for SAP and from –47 to 11 for DAP. Spearman correlation coefficients between the Omron and IBP values were 0.64 for SAP and 0.72 for DAP (p < 0.0001).Conclusions and clinical relevanceAlthough neither device met all the criteria for device validation, the Surgivet presented better agreement with IBP values than the Omron in adult anaesthetized chimpanzees.  相似文献   

13.
OBJECTIVE: To determine cardiovascular responses to administration of butorphanol in isoflurane-anesthetized horses. STUDY DESIGN: Retrospective evaluation of anesthetic records. ANIMALS: Seventy-six horses anesthetized for a variety of clinical surgical procedures. METHODS: Anesthetic records of clinical equine patients anesthetized between January 1999 and December 2003 were searched. The records were reviewed for horses in which anesthesia was induced with ketamine and a benzodiazepine and maintained with isoflurane, and horses that received butorphanol intraoperatively. Exclusion criteria included horses in which the rate of infusion of an inotrope or end-tidal isoflurane concentration was changed 10 minutes before or after the butorphanol bolus. The horses were separated into two groups: group 1 horses received butorphanol at intervals as part of a balanced protocol, group 2 horses had > or = 10% increase in heart rate (HR) or blood pressure within 10 minutes prior to butorphanol administration. RESULTS: Eighty-nine butorphanol administration events matched the criteria for inclusion, 49 in group 1 and 40 in group 2. There were no significant changes after butorphanol administration in systolic arterial pressure (SAP), mean arterial pressure (MAP), diastolic arterial pressure (DAP), and heart rate (HR) in group 1, or in end-tidal carbon dioxide concentration or hemoglobin oxygen saturation in either group. There were significant decreases in SAP (p < 0.0001), MAP (p < 0.0005), and DAP (p < 0.0008) after butorphanol administration in group 2. CONCLUSIONS AND CLINICAL RELEVANCE: The results presented here confirm that butorphanol can be administered to horses during isoflurane anesthesia without adverse effects on HR and arterial blood pressure. The results imply that butorphanol can deepen the plane of anesthesia and obtund sympathetic stimulation from a surgical procedure.  相似文献   

14.
Blood pressure (BP) measurements obtained using 3 indirect BP measuring instruments, a Doppler ultrasonic flowmeter, an oscillometric device, and a photoplethysmograph, were compared with direct arterial pressure measurements in 11 anesthetized cats. The standard deviation of the differences (SOD) between direct and indirect pressure measurements were not significantly different from each other ( P <.01), and ranged from 10.82 to 24.32 mm Hg. The high SDD values indicate that indirect BP estimates obtained with all these devices must be interpreted cautiously in individual patients. The mean errors (calculated as the sum of the differences between direct and indirect pressure measurements divided by the number of observations) of the 3 indirect devices were significantly different for systolic (SAP), diastolic (DAP), and mean (MAP) arterial pressures ( P <.05). The Doppler and photoplethysmographic devices had the highest overall accuracy, as indicated by mean error values of less than 10 mm Hg. Correlation coefficients varied from .88 to .96 for the Doppler flowmeter, and from .85 to .94 for the photoplethysmograph; for both devices, the regression line slopes were close to unity. The Doppler flowmeter detected a pulse under all experimental conditions. The photoplethysmograph was also efficient in obtaining BP measurements, obtaining over 90% of SAP, DAP, and MAP readings attempted. The oscillometric device was the least accurate, with mean error values varying from 10 to 22 mm Hg. Correlation coefficients were high (.90 to .94) for this device, but the slopes of the regression lines were 0.7 to 0.8, indicating a trend for increased error at higher BP. The oscillometric device tended to underestimate BP by increasing amounts as the BP increased. The oscillometric device was the least efficient device for obtaining BP measurements ( P <.01).  相似文献   

15.
ObjectiveTo determine the accuracy of an oscillometric blood pressure monitor in anesthetized sheep.Study designProspective study.AnimalsTwenty healthy adult sheep, 11 males and nine females, weighing 63.6 ± 8.6 kg.MethodsAfter premedication with buprenorphine or transdermal fentanyl, anesthesia was induced with ketamine‐midazolam and maintained with isoflurane and ketamine, 1.2 mg kg?1 hour?1, ± lidocaine, 3 mg kg?1 hour?1. Invasive blood pressure measurements were obtained from an auricular arterial catheter and noninvasive measurements were from a cuff on the metatarsus or antebrachium. Simultaneous invasive and noninvasive measurements were recorded over a range (55–111 mmHg) of mean arterial pressures (MAP). Isoflurane concentration was increased to decrease MAP and decreasing the isoflurane concentration and infusing dobutamine achieved higher pressures. Invasive and noninvasive measurements were compared.ResultsCorrelation (R2) was good between the two methods of measurement (average of three consecutive readings) for systolic (SAP) (0.87), diastolic (DAP) (0.86), and mean (0.90) arterial pressures (p < 0.001). Bias ± SD between noninvasive and invasive measurements for SAP was 3 ± 8 mmHg, for DAP was ?10 ± 7 mmHg, and MAP was ?7 ± 6 mmHg. There was no significant difference between the average of three measurements and use of the first measurement. Correlations using the first measurement were SAP (0.82), DAP (0.84), and MAP (0.89). Bias ± SD for SAP was 3 ±10 mmHg, for DAP was ?11 ± 7 mmHg, and MAP was ?7 ± 6 mmHg. The oscillometric monitor slightly overestimated SAP and underestimated DAP and MAP for both average values and the first reading.Conclusions and clinical relevanceThis oscillometric model provided MAP measurements that were acceptable by ACVIM standards. MAP measurements with this monitor were lower than those found with the invasive technique so a clinical diagnosis of hypotension may be made in sheep that are not hypotensive.  相似文献   

16.
To evaluate the cardiorespiratory changes induced by isoflurane (ISO) anesthesia in the crested caracara (Caracara plancus), eight crested caracaras that weighed 1.0 kg (range 0.9-1.1 kg) were the subjects for the study. The birds were anesthetized by face mask with ISO for brachial artery catheterization. After recovery, anesthesia was re-induced and maintained with ISO with spontaneous ventilation. Electrocardiography, direct systolic arterial blood pressure (SAP), diastolic arterial blood pressure (DAP), mean arterial blood pressure (MAP), respiratory rate (RR), end-tidal carbon dioxide (P(ET)CO2), and cloacal temperature (T degrees C) were measured before induction (baseline, under physical restraint) and after 5, 10, 15, 20, 25, 30, 35, and 40 min of ISO anesthesia. Arterial blood samples were collected for blood gas analysis at baseline, 10, 25, and 40 min. No cardiac arrhythmias were observed in the present study. RR, SAP, DAP, MAP, T degrees C and pH decreased from baseline values, whereas arterial partial pressures of oxygen and carbon dioxide, bicarbonate concentration, and P(ET)CO2 were significantly higher than baseline. Apnea was not observed in any bird. ISO anesthesia is suitable for use in healthy members of this species despite the moderate cardiovascular and respiratory depression produced.  相似文献   

17.
ObjectiveTo determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia.Study designExperimental study.AnimalsSeven healthy warmblood horses, aged 3–11 years, weighing 470–565 kg.MethodsMeasurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg−1 minute−1) over ten minutes followed by norepinephrine (0.1 mg kg−1 IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg−1 IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgResultsA total of 245 paired measurements of systolic (SAP), mean (MAP) and diastolic (DAP) pressures were obtained. The HDO device underestimated blood pressure at hypertensive and normotensive levels and overestimated blood pressure at hypotensive levels. Best agreement was obtained for SAP and MAP within normotensive limits. At normotension, bias ± standard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing.Conclusion and clinical relevanceGood agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable.  相似文献   

18.
OBJECTIVES: To determine the effect of the route and rate of protamine administration on the amount of protamine that could be delivered before a hemodynamic reaction occurred in dogs. STUDY DESIGN: Prospective randomized experimental study. ANIMALS: Twenty adult mixed-breed dogs weighing 25.1+/-2.5 kg. METHODS: Before vascular surgery, the dogs were heparinized to reach an activated clotting time (ACT) of 300 seconds. After completion of the vascular surgery, protamine was administered intravenously until a hemodynamic reaction was recorded. The 4 groups of dogs were given protamine at 5 mg/min (slow) or 10 mg/min (fast) via the cephalic or the jugular veins. Systemic and pulmonary arterial pressures, central venous pressure (CVP), and pulmonary arterial occlusion pressure (PAOP) were recorded before and after protamine administration. The dose of protamine was recorded when a reaction occurred, which was defined as mean arterial pressure (MAP) <60 mm Hg or mean pulmonary arterial pressure (MPAP) >20 mm Hg or more than double the baseline value. RESULTS: Significant decreases in systolic arterial pressure (SAP), MAP, and diastolic arterial pressure (DAP) and significant increases in systolic (SPAP), mean (MPAP), and diastolic (DPAP) pulmonary arterial pressures were recorded after protamine administration. The cephalic slow group had significantly fewer protamine reactions than other groups (chi-square = 8.57, P = .03, df = 3). Significantly more protamine could be delivered from the cephalic vein (52.5+/-14.5 mg) compared with the jugular vein (37.6+/-16 mg) before a reaction occurred (P = .048). CONCLUSION: The rate of administration did not have an effect on the amount of protamine delivered. Adverse reactions were minimized when protamine was administered via the cephalic vein at a slow rate. CLINICAL RELEVANCE: We would recommend delivering protamine after cardiopulmonary bypass or vascular surgery through a peripheral venous route.  相似文献   

19.
In a series of 3 studies, indirect blood pressure measurements were obtained to define normal variance, identify hypertension, and estimate the prevalence of hypertension in apparently healthy dogs. In part 1, we measured values in 5 clinically normal dogs twice weekly for 5 weeks in a home setting. Mean +/- SD systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) was 150 +/- 16 and 86 +/- 13 mm of Hg, respectively. The DAP significantly (P less than 0.01) decreased with repeated measurements over the 5-week period. In part 2, we assessed the variation between blood pressures measured in a clinic vs those measured in the home. Within a 2-week period, measurements were obtained from 10 clinically normal dogs in a private veterinary clinic and again in their home. Significant differences were not observed between clinic and home measurements of SAP and DAP; however, heart rate was significantly (P less than 0.05) higher in the clinic. In part 3, SD about the SAP and DAP mean values were determined in 102 clinically normal dogs. Canine hypertensive status was determined, using statistical methods and data from 102 clinically normal dogs. Values of SAP greater than 202 mm of Hg and DAP greater than 116 mm of Hg were determined to be 2 SD beyond the mean and, therefore, were interpreted to be hypertensive. Approximately 10% of the 102 apparently healthy dogs measured in this study were considered hypertensive on the basis of these criteria. In addition, a border zone of suspected hypertension was estimated, using the mean + 1.282 SD. The SAP border zone was between 183 and 202 mm of Hg, whereas the DAP border zone was between 102 and 113 mm of Hg. Of the 102 dogs, 12 had values within these zones of suspected hypertension.  相似文献   

20.
Background: Greyhounds are known to have a higher systemic arterial blood pressure (BP) than non‐Greyhound dogs. Objectives: The purpose of this study was to determine whether the high systemic BP was because of the white‐coat effect. Animals: Twenty‐two healthy retired racing Greyhounds (RRG) enrolled in a blood donation program. Materials/Methods: We prospectively measured systemic BP in 3 environments: in the hospital by the investigator (Hosp), in the home by the investigator (H/I), and in the home by the owner (H/O). Five serial measurements of systolic, diastolic, and mean arterial pressures (SAP, DAP, MAP) as well as heart rate (HR) were measured by an oscillometric method on the distal forelimb and distal hind limb in all 3 environments. Results: There was a significant difference for SAP, MAP, and HR between the Hosp and both H/I and H/O (P < .001); there were no significant differences for any of the parameters between the H/I and H/O environments. HR, but not SAP, MAP, or DAP (P < .05) decreased in RRG with multiple hospital visits for blood donation before this study. The hind limb SAP was significantly higher than the forelimb SAP (P < .05). Conclusions and Clinical Importance: We conclude that the high SAP, MAP, and HR seen in the hospital setting are likely because of a white‐coat effect. Furthermore, consideration should be given to defining the parameters of normal BP in RRG according to the environment in which they are obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号