首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 27 毫秒
1.

Objectives

The objective is to describe the clinical, radiographic, echocardiographic and angiographic findings in dogs with systemic-to-pulmonary arteriovenous fistula (SPAVF).

Animals

Thirteen medical records of client-owned dogs with a diagnosis of SPAVF were reviewed/analysed.

Methods

This is a retrospective study of case records. Thoracic radiography, transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), three-dimensional TEE, intracardiac echocardiography, fluoroscopy-guided or computed tomography (CT) angiography were carried out.

Results

Based on the TTE, SPAVF was identified in seven of the included dogs. In eight cases, TEE and angiography were both performed and confirmed the diagnosis. Computed tomography angiography was performed in three dogs. A case was diagnosed by TEE alone, another one by three-dimensional TEE and the latter by intracardiac echocardiography.

Conclusions

Transthoracic echocardiography identified seven cases of SPAVF, while definitive diagnosis in the remaining dogs required selective angiography or computed tomography angiography.  相似文献   

2.

Objective

To assess the reaction of client-owned dogs to intravenous (IV) catheter placement after applying a local anaesthetic (EMLA) or placebo cream for either 30 or 60 minutes.

Study design

Prospective, randomized, blinded, placebo-controlled, clinical trial.

Animals

A total of 202 client-owned dogs of various breeds.

Methods

With owner consent, dogs were randomly allocated to one of four treatment groups: EMLA 60 minutes, EMLA 30 minutes, Placebo 60 minutes and Placebo 30 minutes. After the cream was applied for the allocated time, an IV catheter was placed and the behavioural reaction of the dog was scored. The reaction score was analysed using a Kruskal–Wallis test followed by Mann–Whitney U tests of the multiple pairwise comparisons, with Bonferroni correction.

Results

A large number of dogs, even in the placebo groups, did not react to IV catheter placement. However, the Kruskal–Wallis test showed an overall difference between treatment groups (χ2 = 11.029, df = 3, p = 0.012). The pairwise comparisons showed a lower overall reaction score in the EMLA 60 group than in the EMLA 30 and Placebo 60 groups (adjusted p = 0.018 and adjusted p = 0.044, respectively).

Conclusions and clinical relevance

This study shows that EMLA cream applied for 60 minutes reduces the behavioural reaction of dogs to IV catheter placement; therefore, this intervention can be advocated for routine use in veterinary medicine to enhance the welfare of dogs undergoing IV catheter placement.  相似文献   

3.

Objective

To determine if serum cardiac troponin I (cTnI) concentration distinguishes between cardiogenic syncope and collapsing dogs presenting with either generalized epileptic seizures (both with and without cardiac disease) or vasovagal syncope.

Animals

Seventy-nine prospectively recruited dogs, grouped according to aetiology of collapse: generalized epileptic seizures (group E), cardiogenic syncope (group C), dogs with both epileptic seizures and cardiac disease (group B), vasovagal syncope (group V) or unclassified (group U).

Methods

Most patients had ECG (n = 78), echocardiography (n = 78) and BP measurement (n = 74) performed. Dogs with a history of intoxications, trauma, evidence of metabolic disorders or renal insufficiency (based on serum creatinine concentrations >150 μmol/L and urine specific gravity <1.030) were excluded. Serum cTnI concentrations were measured and compared between groups using non-parametric statistical methods. Multivariable regression analysis investigated factors associated with cTnI. Receiver operator characteristic curve analysis examined whether cTnI could identify cardiogenic syncope.

Results

Median cTnI concentrations were higher in group C than E (cTnI: 0.165 [0.02–27.41] vs. 0.03 [0.01–1.92] ng/mL; p<0.05). Regression analysis found that serum cTnI concentrations decreased with increasing time from collapse (p=0.015) and increased with increasing creatinine concentration (p=0.028). Serum cTnI diagnosed cardiogenic syncope with a sensitivity of 75% and specificity of 80%.

Conclusions

Serum cTnI concentrations were significantly different between groups C and E. However, due to the overlap in cTnI concentrations between groups cTnI, measurement in an individual is not optimally discriminatory to differentiate cardiogenic syncope from collapse with generalized epileptic seizures (both with and without cardiac disease) or vasovagal syncope.  相似文献   

4.

Objectives

To determine the prevalence of mitral valve regurgitation (MR) in asymptomatic Swedish Norfolk terriers.

Animals

Seventy-nine privately owned Norfolk terriers.

Materials and methods

A prospective observational study was conducted where dogs were recruited via the Swedish Norfolk terrier club. All dogs were examined using the same protocol including physical examination and Doppler echocardiography.

Results

Fifteen dogs (19%) had a murmur at the time of the examination. A total of 35 dogs (44%) had MR, including 23 dogs (29%) with both MR and tricuspid valve regurgitation and 12 dogs (15%) with MR only, identified on Doppler echocardiography. In addition, 7 dogs (9%) had tricuspid valve regurgitation only. The prevalence of MR increased with increasing age (p < 0.0001).

Conclusions

Mitral valve regurgitation is common in asymptomatic Norfolk terriers with and without murmurs and the prevalence increases with age. The impact of MR in this breed on survival remains to be elucidated by a longitudinal study.  相似文献   

5.

Objectives

We aimed to evaluate safety and efficacy of high-pressure balloon valvuloplasty (HPBVP) for treatment of canine severe pulmonary valve stenosis (PS). A secondary aim was to provide pre-procedure predictors of success.

Animals

Twenty-five dogs.

Methods

Prospective observational study. Dogs with severe PS (echocardiographically derived trans-pulmonary peak/maximum pressure gradient (EDPG) ≥80 mmHg) were recruited. All dogs underwent echocardiography before and 20–24hrs after HPBVP using a high-pressure balloon with rated burst pressures ranging from 12 to 18 ATM. Procedural success was defined as a post-HPBVP EDPG reduction of ≥50% or reduction into at least the moderate category of PS (50–79 mmHg). Optimal result was defined as a post-procedural EDPG ≤30 mmHg.

Results

Initial median (IQR) EDPG for all dogs was 96 (88, 127) mmHg with a post-operative median of 48 (36, 65) mmHg. The median EDPG reduction provided by HPBVP was 63% (39, 68); procedural success rate was 92% (23 dogs). Optimal results were achieved in 56% (14 dogs). There were no significant correlations between EDPG reduction and valve morphology (Type A and Type B) or severity of right ventricular hypertrophy. Pulmonary valve annulus diameter was the only echocardiographic variable that was significantly correlated to EDPG reduction (p = 0.02; r = ?0.46). No dog experienced any anesthetic or surgical complications, and all patients survived the procedure.

Conclusions

In this cohort of 25 dogs with severe PS, HPBVP was safe and effective. The procedural success rate and high number of optimal results achieved with HPBVP suggest future randomized controlled trials comparing HPBVP to conventional valvuloplasty are warranted.  相似文献   

6.

Objective

To determine if concentrations of plasma N-terminal pro-brain natriuretic peptide (NT-proBNP) are increased in dogs with cardiac tamponade and if there is a significant increase in plasma NT-proBNP after pericardiocentesis.

Animals

Ten client-owned dogs with spontaneous cardiac tamponade.

Methods

Prospective clinical study. Cardiac tamponade was suspected from physical examination and confirmed with echocardiography. Blood was collected and plasma NT-proBNP concentrations were measured before and 30–60 min following pericardiocentesis and resolution of cardiac tamponade. Within-subject changes in plasma NT-proBNP were compared by the Wilcoxon signed-rank test.

Results

The plasma NT-proBNP concentrations measured within the reference interval in seven of 10 dogs before pericardiocentesis and in six of 10 dogs following pericardiocentesis. Following pericardiocentesis, there was a statistically significant increase in median NT-proBNP concentration (733 pmol/L, range 250–3,297) compared with the values measured before (643 pmol/L, range 250–3,210, P = 0.004). The NT-proBNP concentration increased in 90% of the dogs following pericardiocentesis.

Conclusions

An upper reference limit of 900 pmol/L for plasma NT-proBNP is insensitive for the diagnosis of pericardial effusion and cardiac tamponade in dogs. Plasma NT-proBNP concentration commonly increases following pericardiocentesis, perhaps related to improved ventricular filling and stretch.  相似文献   

7.

Background

Increased cardiac troponin I (cTnI) concentration has been reported in dogs with atrioventricular (AV) block before and shortly following pacemaker implantation. The role of AV dyssynchrony, age, or concurrent cardiac disease on cTnI concentration remains unknown.

Objectives

To investigate change in cTnI concentration following dual-chamber pacemaker implantation on short- and long-term follow-up and to compare cTnI values to a case-matched control group.

Animals

Thirty-eight client-owned dogs with permanent AV block and 38 matched control dogs.

Methods

Retrospective review of medical records. Pacemaker group consisted of dogs with AV block and dual-chamber pacing. Control group matched the study population in age and cardiac disease. cTnI was compared between pacemaker and control group on short- and long-term follow-up. Different lead types and influence of arrhythmia on cTnI were tested.

Results

cTnI was high at presentation (median 0.66 ng/ml; range 0.03–18.6) and showed a significant reduction over time after pacemaker implantation (p < 0.0001). Median cTnI values were significantly different between pacemaker and control group on short-term (p = 0.0004; 0.11 ng/ml, range 0.03–1.36 versus 0.06 ng/ml, range 0.03–0.46), but not on long-term follow-up (p = 0.0547; 0.14 ng/ml, range 0.03–0.73 versus 0.07 ng/ml, range 0.03–0.46). Lead type and severity of arrhythmia did not show a significant correlation to cTnI concentration.

Conclusions

On long-term follow-up, cTnI remained mildly elevated in some of the pacemaker dogs but was not significantly different to the matched control group.  相似文献   

8.

Introduction

Assessing left atrial (LA) size is an integral part of the cardiac evaluation in dogs. Left atrial size is routinely evaluated by thoracic radiographs or echocardiography.

Objectives

The objectives of the study were to assess agreement of subjective radiographic left atrial enlargement (LAE) between readers, to compare subjective radiographic LAE with echocardiography, and to assess the accuracy and reliability of commonly used Roentgen signs for LAE.

Animals

One hundred one dogs with thoracic radiographs and echocardiography performed on the same day at a veterinary teaching hospital were retrospectively reviewed.

Methods

Thoracic radiographs were reviewed by two cardiologists, two radiologists, and two small animal rotating interns. Radiographs were evaluated for the subjective presence and severity of LAE and for seven Roentgen signs. Echocardiographic LA size was evaluated objectively by the left atrial-to-aortic root ratio and LA volume indexed to body weight. Interreader agreement of radiographic LAE evaluation and agreement between radiographic LAE assessment and echocardiographic LAE were assessed by linearly weighted kappa and intraclass correlation coefficient.

Results

Interreader agreement for the presence and degree of radiographic LAE ranged from moderate to substantial. The agreement between subjective radiographic LAE and echocardiographic LAE was moderate. Single Roentgen signs had poor to fair correlation with echocardiographic LAE.

Conclusions

The present study found that interreader agreement for radiographic classification of LAE was substantial among specialists and moderate for all readers. Subjective, global assessment of radiographic LAE is better than using any single Roentgen sign.  相似文献   

9.
10.

Objective

This study aimed to evaluate cardiac function and compare the concentration of cardiac biomarkers including cardiac troponin I (cTnI), galectin-3 (Gal-3), and N-terminal pro B-type natriuretic peptides (NT-proBNP) in diabetic and control dogs.

Animals

Thirty-nine dogs were included. The diabetic and control groups consisted of 19 and 20 dogs, respectively.

Methods

Plasma cTnI, Gal-3, and NT-proBNP concentrations were measured in the diabetic and control groups. Echocardiography was performed in all dogs to evaluate cardiac structure and function. Echocardiographic values and cardiac biomarker concentrations between the two groups were compared with the Mann–Whitney U test. The p-value < 0.05 was considered statistical significance.

Results

No evidence of cardiac structural changes was detected in diabetic dogs on two-dimensional echocardiography. The echocardiographic values of diabetic and control dogs were within reference intervals. Echocardiographic changes indicating diastolic dysfunction assessed by spectral flow Doppler echocardiography and tissue Doppler imaging were found in diabetic dogs (42.10%) compared with control dogs (10.00%; p = 0.022). Diabetic dogs with durations of diabetes mellitus > 1 year had an increased left ventricular wall thickness and echocardiographic changes suggesting diastolic dysfunction compared with those with duration of diabetes mellitus < 1 year. No evidence of systolic dysfunction was detected in diabetic dogs. No significant difference in plasma cTnI, Gal-3, and NT-proBNP concentrations was found between the two groups.

Conclusions

Echocardiographic changes suggested that left ventricular diastolic dysfunction was detected in diabetic dogs without changes in the concentration of cardiac biomarkers including cTnI, Gal-3, and NT-proBNP compared with the age- and breed-matched control dogs.  相似文献   

11.

Objective

Mitral valve (MV) regurgitation due to degenerative MV disease is the leading cause of cardiac death in dogs. We carried out preliminary experiments to determine the feasibility and short-term effects of beating-heart MV repair using an expanded polytetrafluorethylene (ePTFE) chordal implantation device (Harpoon TSD-5) in dogs.

Animals

This study involved six healthy purpose-bred Beagles (weight range 8.9–11.4 kg).

Material and methods

Following a mini-thoracotomy performed under general anesthesia, the TSD-5 was used to place 1 or 2 artificial ePTFE cords on the anterior MV leaflet or the posterior MV leaflet via a left-ventricular transapical approach. The procedure was guided and monitored by transesophageal echocardiography. Postoperative antithrombotic treatment consisted of clopidogrel or a combination of clopidogrel and apixaban. Dogs were serially evaluated by transthoracic echocardiography at day 1, 7, 14, 21, and 30. The hearts were then examined for evaluation of tissues reactions and to detect signs of endothelialization.

Results

One or two chords were successfully implanted in five dogs. Four dogs completed the 30 days follow-up. One dog died intra-operatively because of aortic perforation. One dog died early post-operatively from a hemorrhagic pleural effusion attributed to overly aggressive antithrombotic treatment. One dog developed a thrombus surrounding both the knot and the synthetic cord. Postmortem exam confirmed secure placement of ePTFE knots in the mitral leaflets in all dogs and the presence of endothelialization of the knots and chords.

Conclusions

These preliminary results demonstrate the feasibility of artificial chordal placement using an ePTFE cordal implantation device in dogs.  相似文献   

12.

Introduction

Left atrial (LA) function can provide useful information in dogs with myxomatous mitral valve disease (MMVD). Recently, we have demonstrated the feasibility of measuring LA longitudinal deformation using speckle-tracking echocardiography (STE) to estimate LA function in healthy dogs. Whether LA strain and strain rate variables provide additional information about LA function and clinical cardiac status in dogs with MMVD remains unexplored.

Animals

Ninety-six client-owned dogs of different breeds with MMVD were prospectively enrolled.

Methods

LA longitudinal deformation was evaluated in each dog by STE and different STE variables were used to assess LA function.

Results

No STE variables differed between American College of Veterinary Internal Medicine Stage B1 and B2 dogs but were lower in Stage C dogs. Peak atrial longitudinal average strain < 27.9%, left-atrial-to-aortic ratio > 2.2 and peak atrial contraction average strain < 7.25% discriminated symptomatic MMVD dogs by receiver operating characteristic analysis with sensitivity and specificity of 100% and 100% (95% confidence interval [CI] 91–100%), 92% (95% CI 78–98%) and 98% (95% CI 87–100%), 100% (95% CI 91–100%) and 95% (95% CI 83–99%), respectively. In 12 dogs with similar left-atrial-to-aortic ratio, peak atrial longitudinal average strain and peak atrial contraction average strain differentiated dogs with subclinical disease from those with congestive heart failure (CHF).

Conclusion

Dogs with MMVD in CHF appear to have lower LA longitudinal strain and strain rate variables compared with dogs with subclinical disease. Further studies are needed to establish if our initial findings can provide useful information for the diagnosis, treatment, and prognosis of dogs with MMVD.  相似文献   

13.

Introduction

An important aspect of heart failure is the progressive ineffectiveness of the salutary natriuretic peptide system and its secondary messenger, 3′,5′-cyclic guanosine monophosphate (cGMP). In humans with acute heart failure, administration of exogenous natriuretic peptide is associated with improvement in clinical signs and reduction of cardiac filling pressures. This study aimed to determine the feasibility, tolerance, and safety of subcutaneous (SC) synthetic canine B-type natriuretic peptide (syncBNP) administration in dogs.

Animals

Six privately owned dogs.

Materials and methods

Dogs were enrolled in a modified 3 + 3 phase I trial. Three dogs initially received doses of 2.5 and 5 μg/kg SC syncBNP followed by an additional three dogs dosed at 5 and 10 μg/kg. Hemodynamic monitoring was performed for 120 min after each injection. Blood and urine samples were collected at 45 and 120 min after injection of 5 μg/kg. Major adverse clinical events that would potentially halt testing were pre-defined.

Results

Four healthy dogs and two dogs with stage B1 mitral valve disease were recruited. Synthetic canine B-type natriuretic peptide was well tolerated at all doses. Synthetic canine B-type natriuretic peptide at 5 μg/kg significantly increased median plasma cGMP (baseline cGMP, 131.5 pmol/mL [range, 91.9–183.6 pmol/mL]; 45 min, 153.6 pmol/mL [140.3–214.3 pmol/mL]; 120 min, 192.7 pmol/mL [139.1–240.1 pmol/mL]; p=0.041).

Discussion and conclusions

We report for the first time administration of syncBNP in privately owned dogs. Administration of SC syncBNP was feasible, well tolerated, safe, and increased plasma cGMP concentration. Further studies using exogenous syncBNP for treatment of heart disease are warranted.  相似文献   

14.

Objectives

To determine whether there are differences in measures of longitudinal right ventricular (RV) systolic function among Boxers with arrhythmogenic right ventricular cardiomyopathy (ARVC) compared with healthy control Boxer dogs. To explore relationships between markers of RV systolic function and age, body weight, gender, arrhythmia frequency, and markers of left ventricular (LV) systolic function in Boxer dogs.

Animals

The study included 50 client-owned Boxer dogs.

Methods

This is a retrospective echocardiographic study. Tricuspid annular plane systolic excursion (TAPSE) and pulsed wave tissue Doppler imaging–derived systolic myocardial velocity of the lateral tricuspid annulus (S') were measured in healthy control Boxers (n = 18), Boxers with ARVC and normal LV systolic function (n = 19), and Boxers with ARVC and reduced LV systolic function (n = 13).

Results

Tricuspid annular plane systolic excursion (p=0.002) and S' (p=0.001) were significantly different between affected and control groups. Significant correlations were found between measures of left heart size and function and both TAPSE and S'. No correlations were found between RV function parameters and age, gender, or body weight in this fairly homogeneous, single-breed population. Receiver operating characteristic curve analysis revealed that both TAPSE and S' had an area under the curve of 0.77 in distinguishing healthy Boxers from those with ARVC.

Conclusions

Tricuspid annular plane systolic excursion and S' are reduced in Boxers with ARVC. In contrast to prior studies evaluating these parameters in dogs of different breeds and body types, no correlation was found between markers of RV function and body weight in this population of Boxer dogs.  相似文献   

15.

Objective

To compare the effectiveness of ultrasound- and electrostimulation-guided nerve blocks of the brachial plexus and to determine whether ultrasound guidance is feasible in conscious dogs.

Study design

Blinded, crossover, experimental study.

Animals

Six clinically healthy adult Beagle dogs.

Methods

The nerves of the brachial plexus of the right thoracic limb were blocked under ultrasound guidance (UNB) in conscious dogs and under electrostimulation guidance (ENB) in anesthetized dogs with bupivacaine (0.4 mL kg–1, 0.25%). Saline (0.4 mL kg–1) was injected in control animals. Sensory nerve blockade was evaluated by scoring cutaneous sensation in targeted nerves. Motor nerve blockade was evaluated based on weight bearing, conscious proprioception and withdrawal reflex scores. Times to execute the technique in UNB and ENB were compared using t tests (p < 0.05). Scores for sensory and motor nerve blockades in each treatment were compared with scores before treatment and with control treatment scores using nonparametric repeated-measures two-way analysis of variance. Time to onset and duration of sensory nerve block were assessed using scores for four sensory nerve functions. A successful sensory nerve block was defined by decreases in scores for these functions. Success rates of nerve blocks were compared among treatments using McNemar’s test.

Results

In UNB and ENB, onset times of sensory nerve blocks were 1 hour and 1.5 hours, respectively. Onset times of motor nerve blocks were 0.5 hour in both treatments. In UNB and ENB, durations of sensory nerve block were 3 hours and 0.5 hour, respectively, and durations of motor nerve block were 7.5 hours and 6.5 hours, respectively. Success rates did not differ between the techniques.

Conclusions and clinical relevance

The UNB brachial plexus block had a shorter onset time and longer duration than ENB. UNB can be performed in conscious dogs or those under mild sedation.  相似文献   

16.

Introduction

The time from the onset of the P wave on electrocardiogram to the peak of late diastolic wave signal (PA-TDI interval) recorded by left atrial pulsed-wave tissue Doppler imaging (PW-TDI) is a surrogate of the total atrial conduction time, and it can predict the development of new-onset atrial fibrillation (AF) in people. This study investigated whether PA-TDI interval measured with PW-TDI at the level of lateral aspect of the mitral valve annulus could identify dogs which developed AF within 6 months after echocardiography.

Animals

Forty-two dogs with different cardiac diseases were included; 21 dogs developed AF within 6 months after echocardiography (AF group) and 21 dogs did not (non-AF group). Each AF case was matched with a non-AF case for body weight and left atrium:aortic root ratio.

Methods

This was a retrospective study. Review of signalment, underlying disease and echocardiography data were included. PA-TDI interval was measured offline from acquired PW-TDI images. PA-TDI interval and standard echocardiographic variables were compared between groups. Receiver operator characteristic curves were used to identify the best AF predictor. Univariate and multivariate regression were used to evaluate predictors of PA-TDI interval.

Results

The AF group had significantly greater 2D left atrial maximal diameter, left-ventricular (LV) end-diastolic volume, M-Mode LV internal diameter and LV end-systolic volume index. PA-TDI was significantly longer in the AF group, and it was superior to other echocardiographic variables in predicting AF development within 6 months (AUC = 0.896).

Conclusions

PA-TDI interval measured with PW-TDI at the lateral mitral valve annulus may identify dogs at risk of developing AF.  相似文献   

17.

Introduction

Accessory pathways (APs) in dogs are mostly right-sided, display nondecremental conduction, and mediate atrioventricular reciprocating tachycardias (AVRTs). Radiofrequency catheter ablation (RFCA) is considered the first-line therapy in human patients to abolish electrical conduction along APs.

Animals

Seventy-six consecutive client-owned dogs.

Material and Methods

Retrospective study to describe the precise anatomical distribution and the electrophysiologic characteristics of APs in a large population of dogs and to evaluate long-term success and complication rates of RFCA.

Results

Eighty-three APs were identified in 76 dogs (92.1% with single APs and 7.9% with multiple APs); 96.4% were right-sided, 3.6% left-sided. Conduction along the APs was unidirectional and retrograde in 68.7% of the cases and bidirectional in 31.3%. Accessory pathways presented retrograde decremental properties in 6.5% of the cases. They mediated orthodromic AVRT in 92.1% of the cases and permanent junctional reciprocating tachycardia in 6.5%. In one case, no AVRT could be induced. In 97.4% of dogs, RFCA was attempted with an acute success rate of 100%. In 7.7% of cases, recurrence of the tachycardia occurred within 18 months, followed by a second definitively successful ablation. A major complication requiring pacemaker implantation was identified in 2.6% of dogs.

Discussion

Accessory pathway distribution and electrophysiologic properties in these 76 dogs were similar to previous report. Long-term success and complication rates of RFCA in dogs appeared very similar to results of humans.

Conclusion

Radiofrequency catheter ablation of APs can be performed with a high success rate and low incidence of complications.  相似文献   

18.

Objective

To investigate whether the use of a heat and moisture exchanger (HME) preserves body temperature in dogs weighing <10 kg anaesthetised for magnetic resonance imaging (MRI).

Study design

Prospective, randomised, clinical trial.

Animals

Thirty-one client-owned dogs.

Methods

Dogs were assigned randomly to a treatment group [HME (n = 16) or no HME (n = 15)]. Dogs were pseudorandomised according to the premedication they were administered, either dexmedetomidine or no dexmedetomidine. Induction agents were not standardised. General anaesthesia was maintained with isoflurane vaporised in 100% oxygen delivered using a T-piece and a fresh gas flow of 600 mL kg?1 minute?1. Rectal temperature was measured before premedication (T1), after induction (T2), before moving to the MRI unit (T3) and at the end of the MRI scan (T4). Ambient temperatures were measured in the induction room, outside and inside the MRI unit. Data were analysed using a general linear model with T4 as the outcome variable. Linear correlations were performed between T1, T2, T3 and T4, and variables that predicted T4 were investigated.

Results

Sex, age and body mass were not significantly different between groups. There were no significant differences in rectal temperature between groups at any time point (group with HME at the end of MRI = 36.3 ± 1.1 °C; group with no HME at the end of MRI = 36.2 ± 1.4 °C) but at the end of the MRI, dogs administered dexmedetomidine (36.6 ± 0.7 °C) had a higher rectal temperature compared with dogs not administered dexmedetomidine (35.9 ± 1.6 °C) for premedication. Rectal temperature varied directly with ambient temperature in MRI scanning room and inversely with anaesthetic duration.

Conclusions and clinical relevance

Using an HME did not alter body temperature in dogs weighing <10 kg undergoing an MRI, but including dexmedetomidine in the premedication regimen seemed to preserve the body temperature during anaesthesia.  相似文献   

19.

Objective

To test the efficacy of intraoperative intrafragmentary administration of bupivacaine (haematoma block) in controlling postoperative pain in dogs undergoing osteosynthesis of long-bone isolated diaphyseal fractures.

Study design

Randomized, ‘blinded’, placebo-controlled, prospective study.

Animals

A total of 23 client-owned dogs with isolated long-bone fractures.

Methods

Dogs were allocated randomly to two groups: bupivacaine group (B) or placebo group (P). Group B dogs (n = 11) were administered an intraoperative intrafragmentary injection of 0.5% bupivacaine (1.1 mg kg–1) just before fracture fixation, whereas group P dogs (n = 12) were administered normal saline. Postoperative pain evaluations using the University of Melbourne Pain Scale (UMPS) and algometer were performed upon arrival to the recovery room and 1, 2, 4, 6, 8, 20 and 32 hours later. Algometer measurements were performed on: the incision site, a healthy region near the fracture line and the contralateral healthy limb. When the pain score exceeded 14 points in the UMPS, rescue analgesia was administered. The time-standardised area under the curve (AUCst) was used to compare UMPS scores and mechanical pain thresholds between the two groups.

Results

None of the group B dogs required rescue analgesia, whereas eight of the 12 group P dogs did (p = 0.001). The pain threshold AUCst at the incision line was higher in group B [16.3 (2.9–41.6) N] than in group P [5.6 (2.5–17.4) N] (p = 0.029). The mean UMPS score AUCst was lower in group B (3.7 ± 1.8) than in group P (9.4 ± 4.6) (p = 0.016). In a small number of animals of both groups that were evaluated radiologically, adequate bone healing was noted.

Conclusions and clinical relevance

An intraoperative bupivacaine haematoma block is a simple, quick and effective method that can be used to aid in postoperative pain control in dogs submitted to long-bone osteosynthesis.  相似文献   

20.

Objectives

To determine the short-term safety and biologic activity of radiation therapy (RT) for presumptive cardiac hemangiosarcoma in pet dogs.

Animals

Six dogs with echocardiographic evidence of a right atrial/auricular mass, and hemorrhagic pericardial effusion, were enrolled in a prospective, single-arm clinical trial.

Methods

A single fraction of 12 Gy was delivered using conformal external beam irradiation. Serum cardiac troponin I and plasma concentrations of vascular endothelial growth factor were quantified before, 4 and 24 h after RT. The frequency of required pericardiocenteses (quantified as the number of pericardiocenteses per week) before RT was compared to that after treatment. Overall survival time was determined.

Results

No treatment-related complications were observed. Pericardiocentesis was performed an average of 0.91 times per week before RT, and an average of 0.21 times per week after RT; this difference was statistically significant (p=0.03, as compared using a Wilcoxon signed-rank test of paired data). Pre- and post-treatment plasma vascular endothelial growth factor concentrations were not significantly different at any time point; there was a statistically significant (p=0.04; Friedman's test for non-parametric repeated measures) increase in cardiac troponin concentrations 4 h after irradiation. Median overall survival time was 79 days.

Conclusions

In this population of dogs, RT was delivered without complication, and appears to have reduced the frequency of periacardial tamponade that necessitated pericardiocentesis. Serum cardiac troponin levels are altered after RT. RT alone, or in combination with chemotherapy, may provide clinical benefit to dogs with presumptive diagnoses of cardiac hemangiosarcoma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏