首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Two-dimensional real-time, M-mode and Doppler echocardiographic measurements were made in 11 adult wolves (Canis lupus) anaesthetised with an intramuscular combination of medetomidine, ketamine, butorphanol and acepromazine followed by isoflurane in oxygen. M-mode measurements of the left ventricle, B-mode measurements of the left atrium and aorta, systolic indices, and Doppler measurements of aortic and pulmonary blood outflow, and of mitral and tricuspid blood inflow, were recorded. The values obtained were compared with those reported for dogs of similar bodyweight and body type. The diastolic measurements of the cardiac chambers and walls were similar to those reported for healthy, conscious dogs, but the use of anaesthesia probably resulted in the markedly different systolic cardiac measurements, systolic indices and Doppler blood flow velocities observed in the wolves. Mild mitral regurgitation, probably due to mitral endocardiosis, was observed in one wolf, and trivial functional mitral insufficiency was observed in five others.  相似文献   

2.
Two-dimensional, M4-mode, and color flow Doppler echocardiography was performed in 29 (18 females, 11 males) clinically healthy ferrets anesthetized with isoflurane. M-mode measurements of the left ventricle, left atrial appendage diameter (LAAD), and aorta (Ao) were obtained. The fractional shortening and LAAD/Ao ratio were calculated. The values of the M-mode measurements were compared between the male and female ferrets using a Student's t-test. No significant differences were found. The difference in body weight between the male and female ferrets was highly significant (P<0.001), but no significant correlation was found between body weight and M-mode measurements. Color flow Doppler examinations of the mitral, tricuspid, aortic, and pulmonary valves were recorded and there was minor valvular regurgitation in five ferrets, which was considered nonsignificant.  相似文献   

3.
Sixty clinically normal German shepherd dogs, 31 males and 29 females, ranging in age from 1 and 5 years and with a body weight ranging from 22 to 37.2 kg, were examined by the two-dimensional mode, M-mode, and Doppler echocardiography. In Doppler mode, the mitral valve flows were obtained, where the aim was to determine the velocity peaks and ratios of the E and A waves and the mitral E wave deceleration time. The velocity peaks were obtained for the tricuspid, pulmonary and aortic valves. On the left ventricular outflow tract flow, the time velocity integral and aortic cross-sectional area was used to calculate the cardiac output. A statistically significant correlation with the body weight was found for the systolic left atrial and diastolic aortic diameter on two-dimensional mode. On M-mode, there was a significant correlation between the body weight and the systolic left atrium and diastolic aortic dimension, systolic and diastolic left ventricular, septal and posterior wall dimensions. Doppler echocardiography showed that there was no significant correlation between the body weight and the mitral, tricuspid, pulmonary and aortic valves flows. These results demonstrate that it is important to know the normal echocardiographic values for German shepherd dogs because there are some characteristics peculiar to this particular breed. The data obtained is expected to be helpful for studies on small animal cardiology.  相似文献   

4.
30 warmblood horses were examined before and after sedation with 20 micrograms/kg BW detomidine, to determine changes of cardiac function parameters, using B-mode, M-mode and Doppler echocardiography. 15 horses showed a heart murmur, but no clinical signs of cardiac heart failure, 15 horses had neither a heart murmur nor other signs of cardiac disease. After sedation with detomidine we could recognise a significant increase of end-diastolic left atrium diameter, an increase of end-systolic left ventricular diameter and aortic root diameter. The end-systolic thickness of papillary muscle and interventricular septum showed a decrease. Fractional shortening and amplitude of left ventricular wall motion was decreased after sedation. The mitral valve echogram revealed a presystolic valve closure and an inflection in the Ac slope (B-notch) in xy horses before sedation. Both increased after sedation with detomidine. Doppler echocardiography showed a decrease of blood flow velocity and velocity time integral (VTI) in the left and right ventricular outflow tract after sedation. Regurgitant flow signals were intensified following sedation in xy horses, especially at the mitral valve.  相似文献   

5.
OBJECTIVE: To determine M-mode and Doppler echocardiographic reference values in healthy New Zealand white rabbits. ANIMALS: 52 healthy male rabbits. PROCEDURES: The rabbits were anesthetized and M-mode measurements of the left ventricle, left atrium, and aorta and Doppler measurements of pulmonary and aortic outflow and mitral inflow were recorded. RESULTS: Mean +/- SD heart rate during echocardiographic examination was 155 +/- 29 beats/min. Mean +/- SD measurements in diastole and systole for the interventricular septum thickness, left ventricular internal diameter, and left ventricular free wall thickness were 2.03 +/- 0.37 mm and 3.05 +/- 0.45 mm; 14.37 +/- 1.49 mm and 10.25 +/- 1.22 mm; and 2.16 +/- 0.25 and 3.48 +/- 0.55 mm, respectively. Mean +/- SD left atrial-to-aortic diameter ratio was 1.17 +/- 0.14, and mean +/- SD mitral valve E-point-to-septal separation interval was 1.71 +/- 0.29 mm. Mean +/- SD for fractional shortening and ejection fraction were 30.13 +/- 2.98% and 61.29 +/- 4.66%, respectively. Mean +/- SD maximal aortic and pulmonary artery outflow velocities were 0.85 +/- 0.11 m/s and 0.59 +/- 0.10 m/s, respectively, and the peak E-to-peak A wave velocity ratio of the mitral valve was 2.19 +/- 0.46. CONCLUSIONS AND CLINICAL RELEVANCE: Results provide echocardiographic reference values for young adult male New Zealand white rabbits anesthetized with ketamine and medetomidine. Values obtained from unanesthetized rabbits, rabbits sedated with other agents, or rabbits of different size may differ from those reported here.  相似文献   

6.
Kerstin  Hansson  DVM  Jens  Häggström  DVM  PhD  Clarence  Kvart  DVM  PhD  Peter  Lord  BVSc  FRCVS 《Veterinary radiology & ultrasound》2002,43(6):568-575
Two-dimensional (2-D) echocardiographic measurement of the left atrium (LA) has the potential to be more accurate than the standard M-mode method, because the LA body can be measured. We evaluated a 2-D method for measuring LA and aorta (AO) in a right parasternal short-axis view and compared it to the M-mode method. An index for LA size (LA/AO) was calculated in 166 cavalier King Charles spaniels, 56 normal and 110 dogs with mitral regurgitation (MR) of varying degrees secondary to chronic valvular disease. In normal dogs, the AO-2-D and LA/AO-2-D did not correlate to body weight (BW) or BW2; whereas, all M-mode values and the LA-2-D were significantly (p < .05) related to both BW parameters. In normal dogs, there was no difference between M-mode and 2-D indices. For all dogs (normal and dogs with MR) there was an 11% bias between the M-mode and 2-D index with the LA/AO-2-D being higher than the LA/AO-M. The association between the mean and the difference of the indices demonstrated a quadratic relationship. Dogs with a mean LA/AO of 2.0-2.5 showed the largest difference between the two indices. Small values for the 2-D coefficients of variation for respiration and stage of diastole were found; 3.4 and 3.1%, respectively. The 2-D index is more sensitive to LA enlargement than the M-mode index.  相似文献   

7.
DOPPLER ECHOCARDIOGRAPHY IN THE NORMAL DOG: PART II   总被引:1,自引:0,他引:1  
Doppler echocardiography was used to determine blood flow velocities in the normal canine heart. The areas examined were the mitral valve, left atrium, tricuspid valve, right atrium, aortic valve, left ventricular outflow tract, pulmonic valve and right ventricular outflow tract. This study then statistically evaluated the influence of breed, age, sex, heart rate, mass and various interactions of these factors on the cardiac flow values determined. Mass and heart rate had the most significant effect on the various determinations with decreasing mass and increasing heart rates generally resulting in increasing peak and mean velocities. The pulmonary artery was statistically judged as being the flow area most susceptible to such influences. Comparisons were made between pulsed and continuous wave Doppler for peak velocities over the four valve areas with only aortic flow, as measured from the left caudal view, showing a significant difference between the two techniques. Mitral flow as compared to tricuspid flow showed a statistically significant difference between peak late diastolic velocities only. The ratio of early mitral diastolic flow to late mitral diastolic flow was always greater than one. Pulmonary flow showed a number of statistically significant differences when compared to aortic flow.  相似文献   

8.
ObjectivesThe objectives of this study were (1) to assess the potential effect of body weight (BW), age, and gender on the most commonly used echocardiographic and conventional Doppler variables in a large population of healthy Cavalier King Charles Spaniels (CKCS), and (2) to establish the corresponding reference intervals (RI).Animals134 healthy adult CKCS.MethodsUltrasound examinations were performed by trained observers in awake dogs. M-mode variables included left ventricular (LV) end-diastolic and end-systolic diameters, LV free wall and interventricular septal thicknesses at end-diastole and end-systole, and LV fractional shortening (FS%). The left atrium (LA) and aortic (Ao) diameters were measured using a 2D method, and the LA/Ao was calculated. Pulsed-wave Doppler variables included peak systolic aortic and pulmonary flow velocities, mitral E and A waves, and E/A ratio. Effects of BW, age, and gender on these 15 variables were tested using a general linear model, and RIs were determined by applying the statistical procedures recommended by the Clinical and Laboratory Standards Institute.ResultsA significant BW effect was observed for all variables, except LA/Ao, FS%, and mitral E/A ratio. A significant but negligible effect of gender and age was also observed for 5/15 and 4/15 of the tested variables, respectively. Only the BW effect on M-mode variables was considered as clinically relevant and the corresponding regression-based RIs were calculated.ConclusionsBody weight should be taken into account when interpreting echocardiographic values in CKCS, except for LA/Ao, FS%, and mitral E/A ratio.  相似文献   

9.
OBJECTIVE: To determine the range of various cardiac parameters using echocardiography in apparently normal, healthy English Bull Terriers. DESIGN: Fourteen English Bull Terriers were selected for study. Cardiac auscultation of the parents of these dogs was normal. Echocardiographic examination of one parent of each animal showed: no mitral or aortic valve abnormalities; no myocardial lesions; no two dimensional evidence of fixed or dynamic left ventricular outflow tract obstruction; and no systolic aortic or left ventricular outflow tract turbulence on colour flow Doppler examination. The 14 selected dogs did not have arrhythmias or murmurs, and on echocardiographic examination had similar findings to their parents. Systolic blood pressure was measured in all dogs and they had no clinical evidence of Bull Terrier polycystic kidney disease or Bull Terrier hereditary nephritis. PROCEDURE: All dogs were auscultated and subjected to a sequential global echocardiographic assessment of the heart, including two dimensional long and short axis, and colour flow Doppler interrogation of the mitral and aortic valves. Dimensional measurements, including those from the left atrium, aortic annulus and left ventricle, were taken from a right parasternal window, and derived values such as fractional shortening, stroke volume and left atrial to aortic annulus ratio were calculated. Peak systolic aortic velocity was measured from the left parasternal window using two dimensional-guided pulsed wave Doppler with angle correction. Systolic blood pressure was measured using a Doppler monitor. The absence of Bull Terrier polycystic kidney disease was determined using renal ultrasonography, and of Bull Terrier hereditary nephritis using urinary protein to creatinine ratio. RESULTS: These 14 dogs had greater left ventricular wall thickness and smaller aortic root diameters than those reported as normal for other breeds of comparable body size. Left atrial dimensions were also larger, however this may have been due to the "maximising" method of measurement. These apparently normal English Bull Terriers also had higher aortic velocities than those reported for other breeds, possibly due to a smaller aortic root diameter or other anatomic substrate of the left ventricular outflow tract, lower systemic vascular resistance, or breed-specific "normal" left ventricular hypertrophy. While these dogs were selected to be as close to normal as possible, the breed may have a particular anatomy that produces abnormal left ventricular echocardiographic parameters. CONCLUSION: These echocardiographic parameters may be used to diagnose left ventricular outflow tract obstruction and left ventricular hypertrophy, and inaccurate diagnoses may result if breed-specific values are not used.  相似文献   

10.
Heart murmurs are caused by turbulent blood flow or by vibration of cardiac structures. Turbulent blood flow may originate from structural heart disease or from physiological phenomena. The aims of this study were to establish the cause of heart murmurs in apparently healthy adult cats and to determine whether a heart murmur is a reliable indicator of heart disease. In this retrospective study, we reviewed the medical records of cats in which a heart murmur was detected during physical examination by one of the authors in the period January 2008 to December 2009. Cats younger than 6 months and those with systemic disease were excluded. Timing, grade, and point of maximum intensity of the murmur were determined by one observer (MD) before 2D-, M-mode and Doppler echocardiography. Fifty-seven cats (median age 76 months, range 6-194) were included, 30 neutered females and 27 neutered males. All murmurs were systolic and varied in intensity from 2/6 to 5/6. The point of maximum intensity was the left or right parasternal region in 34/57 (61%) of murmurs. Murmurs were caused by dynamic left ventricular outflow tract obstruction in 25/57 (44%) cats, dynamic right ventricular outflow tract obstruction in 9/57 (16%) cats, and combined dynamic left and right outflow tract obstruction in 11/57 (19%) cats. In 5 (9%) cats the cause of the murmur could not be identified. Heart disease was present in 50 (88%) cats, namely, left ventricular hypertrophy in 44 (77%) and congenital defects in 6 (11%) cats. In conclusion, most heart murmurs in apparently healthy cats are detected in the left or right parasternal region and are caused by dynamic left and right ventricular outflow tract obstruction. Because most cats (88%) with a heart murmur had heart disease in this study, if a heart murmur is detected in an apparently healthy cat, echocardiography is recommended to determine the cause of the heart murmur and the presence of heart disease.  相似文献   

11.
Twenty horses with mitral valve insufficiency, but without signs of congestive heart failure, and five horses without signs of heart disease were examined before and after medication with an angiotensin-converting enzyme (ACE) inhibitor. The examination included echocardiography assessment as well as heart catheterization. The echocardiographic examination included B-mode, M-mode, conventional and colour Doppler techniques. For 8 weeks, all horses were treated with Accupro 20 (active substance: Quinapril) at an oral dose rate of 120 mg/horse/day. A follow-up of the horses with mitral valve insufficiency after 8 weeks revealed a statistically significant increase in the stroke volume and the cardiac output as well as a decrease in regurgitation velocity time integral (VTI). The regurgitation blood velocity remained the same. The severity of mitral valve insufficiencies revealed a moderate improvement in five horses, from moderate to mild, after therapy. Significant changes of cardiac dimension (B-mode) and shortening fraction (M-mode) before and after treatment could not be observed. The owners' judgement of the horses' performance was that of a minor improvement. In the horses without clinical findings the results of examination before and after treatment remained the same.  相似文献   

12.
OBJECTIVE: To identify factors (eg, familiarity, sex, neutering status, and time of year) associated with aggression between domestic ferrets and test a method for reducing aggression when introducing ferrets. DESIGN: Prospective trial. ANIMALS: 56 healthy domestic ferrets. PROCEDURE: To identify variables associated with aggression, pairs were placed in an enclosed area and observed. To test whether increasing familiarity would decrease aggression when introducing ferrets, pairs of ferrets were housed in separate cages next to each other or in separate rooms for 2 weeks prior to introduction. RESULTS: 49 of 82 pairs of strangers fought, but 31 cage mate pairs did not. Time of year had no apparent effect. Pairs consisting of 2 neutered females or 2 sexually intact males were significantly more likely to fight than were pairs consisting of a neutered female and a sexually intact male. Pairs caged next to each other for 2 weeks prior to introduction were no less likely to fight than were control pairs. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that familiarity, sex, and neutering status are important determinants of aggression between ferrets. If unfamiliar neutered ferrets are introduced, then pairing 2 males or a male and female would likely result in the lowest levels of aggression. However, neutered females and sexually intact males are not indiscriminately aggressive, as a neutered female can be paired with a sexually intact male without resulting in aggression. Caging ferrets next to each other for 2 weeks does not decrease aggression when the ferrets are introduced.  相似文献   

13.
Objectives : To assess the feasibility of performing electrocardiography (ECG) and echocardiography on conscious ferrets and to establish reference values for this species under these conditions. Methods : End‐systolic and end‐diastolic left ventricular (LV) diameters, LV and interventricular septal thicknesses were measured by M‐mode echocardiography, while left atrial, aortic and pulmonary trunk diameters were determined by two‐dimensional echocardiography in 46 ferrets. In some animals the maximum velocities of blood flow in the aorta and the pulmonary trunk were also measured by spectral Doppler. ECG examinations were performed by using limb leads both in right lateral recumbency and in the so‐called “hanging” position. In the course of the ECG examinations (n=43), the occurrences, directions, durations and amplitudes of the P, QRS and T waves and the duration of the PR‐ and QT intervals were recorded for all six leads. Results : ECG and echocardiography were successfully performed on non‐sedated ferrets in 90 and 96% of the cases, respectively. Males were significantly heavier and had larger cardiac dimensions compared to females. Clinical Significance : Performance of both echocardiography and ECG are feasible techniques in conscious ferrets, and reference values are now available for future comparisons.  相似文献   

14.
15.
Pulsed-wave Doppler echocardiography was performed on 30 clinically normal 1- to 6-year-old racing Standardbreds. There were 13 females, 13 geldings, and 4 stallions. Cardiac disease was not detected with M-mode, 2-dimensional real-time or pulsed-wave Doppler echocardiography. Normal flow velocities for right and left atrial outflow, right and left ventricular outflow, the aorta, and pulmonary artery were determined. Peak flow velocities for right and left atrial outflow occurred during the rapid filling phase and were higher toward the mitral valve (mean, 0.70 +/- 0.24 m/s) than toward the tricuspid valve (mean, 0.49 +/- 0.17 m/s). Peak flow velocities in the right and left ventricular outflow tracts were similar (means, 0.81 +/- 0.10 m/s and 0.75 +/- 0.39 m/s, respectively). Peak flow velocities in the pulmonary artery (mean, 1.09 +/- 0.42 m/s) and aorta (mean, 1.01 +/- 0.29 m/s) were similar, although flow peaked earlier in systole in the aorta than in the pulmonary artery.  相似文献   

16.
The objective of this retrospective study is to determine normal reference values for 2-Dimension (2D) and Motion-mode (M-mode) echocardiographic parameters in nonsedated healthy young adult Sphynx cats and to compare them to those of the domestic shorthair (DSH). 131 Sphynx cats underwent cardiac screening prior to breeding. The control group consisted of 30 healthy adult domestic cats. A complete cardiac ultrasound was performed on all cats using right parasternal long and short axis views. There were few echocardiographic parameters in the Sphynx that differed from those of the healthy DSH. Only the left atrial (LA) dimension in 2D and M-mode, the left atrial/aortic (LA/Ao) ratio and the internal dimension of the left ventricle in systole (LVIDs) measured with M-mode were different. In conclusion, although the heart of Sphynx cat can often have a particular 2-D echocardiographic appearance, the M-mode cardiac dimensions are similar to those of the DSH.  相似文献   

17.
Recommendations are presented for standardized imaging planes and display conventions for two-dimensional echocardiography in the dog and cat. Three transducer locations (“windows”) provide access to consistent imaging planes: the right parasternal location, the left caudal (apical) parasternal location, and the left cranial parasternal location. Recommendations for image display orientations are very similar to those for comparable human cardiac images, with the heart base or cranial aspect of the heart displayed to the examiner's right on the video display. From the right parasternal location, standard views include a long-axis four-chamber view and a long-axis left ventricular outflow view, and short-axis views at the levels of the left ventricular apex, papillary muscles, chordae tendineae, mitral valve, aortic valve, and pulmonary arteries. From the left caudal (apical) location, standard views include long-axis two-chamber and four-chamber views. From the left cranial parasternal location, standard views include a long-axis view of the left ventricular outflow tract and ascending aorta (with variations to image the right atrium and tricuspid valve, and the pulmonary valve and pulmonary artery), and a short-axis view of the aortic root encircled by the right heart. These images are presented by means of idealized line drawings. Adoption of these standards should facilitate consistent performance, recording, teaching, and communicating results of studies obtained by two-dimensional echocardiography.  相似文献   

18.
OBJECTIVE: To determine plasma concentrations of adrenocorticotrophic hormone (ACTH) and alpha-melanocyte stimulating-hormone (alpha-MSH) in healthy ferrets and ferrets with hyperadrenocorticism. ANIMALS: 16 healthy, neutered, privately owned ferrets, 28 healthy laboratory ferrets (21 sexually intact and 7 neutered), and 28 ferrets with hyperadrenocorticism. PROCEDURES: Healthy ferrets were used for determination of reference plasma concentrations of ACTH and a-MSH. Diagnosis of hyperadrenocorticism was made on the basis of history, clinical signs, urinary corticoid-to-creatinine ratios, ultrasonography of the adrenal glands, and macroscopic or microscopic evaluation of the adrenal glands. Blood samples were collected during isoflurane anesthesia. Plasma concentrations of ACTH and alpha-MSH were measured by radioimmunoassay. RESULTS: Plasma concentrations of ACTH in 23 healthy neutered ferrets during the breeding season ranged from 4 to 145 ng/L (median, 50 ng/L). Plasma concentrations of alpha-MSH in 44 healthy neutered or sexually intact ferrets during the breeding season ranged from < 5 to 617 ng/L (median, 37 ng/L). Reference values (the central 95% of the values) for ACTH and alpha-MSH were 13 to 100 ng/L and 8 to 180 ng/L, respectively. Plasma concentrations of ACTH and alpha-MSH in ferrets with hyperadrenocorticism ranged from 1 to 265 ng/L (median, 45 ng/L) and 10 to 148 ng/L (median, 46 ng/L), respectively. These values were not significantly different from those of healthy ferrets. Plasma ACTH concentrations of sexually intact female ferrets in estrus were significantly higher than those of neutered females. CONCLUSIONS AND CLINICAL RELEVANCE: Ferrets with hyperadrenocorticism did not have detectable abnormalities in plasma concentrations of ACTH or alpha-MSH. The findings suggest that hyperadrenocorticism in ferrets is an ACTH and alpha-MSH-independent condition.  相似文献   

19.
This study examined the blood flow velocities and flow patterns in the normal dog using pulsed wave spectral Doppler echocardiography in eight areas of the heart. Two breeds of dogs, aged between 8 and 112 weeks and of both sexes, were used. The dogs were fully conscious and no drugs were used. The areas examined were the mitral valve, left atrium, tricuspid valve, right atrium, aorta, left ventricular outflow tract, pulmonary valve and the right ventricular outflow tract. The peak and mean velocities, direction of flow and whether flow was systolic or diastolic was determined for each of these flow areas. Additionally each of these waveforms were described. Aortic flow was also measured from the thoracic inlet by continuous wave Doppler.  相似文献   

20.
OBJECTIVE: To determine the prevalence of Doppler echocardiography-derived evidence of pulmonary arterial hypertension (DEE-PAH) in dogs with mitral valve disease (MVD) classified according to the International Small Animal Cardiac Health Council (ISACHC) heart failure classification scheme and various echocardiographic and Doppler indices of MVD severity. DESIGN: Retrospective case series. ANIMALS: 617 dogs examined from 2001 to 2005 with MVD in ISACHC classes I to III. PROCEDURES: Dogs were examined echocardiographically. Criteria used for systolic and diastolic DEE-PAH were detection of high tricuspid (> or = 2.5 m/s) and telediastolic pulmonic (> or = 2.0 m/s) valvular peak regurgitant jet velocities, respectively, by use of continuous-wave Doppler echocardiography. RESULTS: 86 (13.9%) dogs with MVD had a diagnosis of DEE-PAH. Severity and prevalence of DEE-PAH increased with ISACHC class (3.0%, 16.9%, 26.7%, and 72.2% prevalences for ISACHC classes Ia, Ib, II, and III, respectively). A significant correlation between systolic or diastolic pulmonary arterial pressure and left atrial-to-aortic diameter ratio (LA/Ao) was detected. Doppler echocardiography-derived evidence of pulmonary arterial hypertension was detected in 18 dogs with values of LA/Ao within reference range, all of which had moderate (n = 2 dogs) or severe (16) mitral valve regurgitation on color Doppler imaging. CONCLUSIONS AND CLINICAL RELEVANCE: The prevalence and degree of DEE-PAH were related to the severity of MVD. Changes associated with DEEPAH may be detected in early stages of the disease, but only in dogs with severe mitral valve regurgitation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏