首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Blood samples were collected simultaneously from the pulmonary artery, jugular vein, cephalic vein, and carotid artery in awake dogs. Blood-gas and acid-base values were measured from these blood samples in normal dogs and in dogs after production of metabolic acidosis and metabolic alkalosis. The values obtained from each of the venous sites were compared with those obtained from arterial blood to determine if venous blood from various sites accurately reflected acid-base balance and could therefore be used in the clinical patient. The results of this study demonstrated significant differences between the blood from various venous sites and the arterial site for PCO2 and pH in all acid-base states. Significant differences for standard bicarbonate (SHCO3) were found only when jugular and cephalic venous blood were compared with arterial blood in dogs with a metabolic acidosis. No significant differences were found for BE when blood from the venous sites was compared with arterial blood. The values for pH, HCO3, TCO2, BE, and SHCO3 measured on blood collected at the various venous sites were found to correlate well with those obtained from arterial blood, with a correlation coefficient of 0.99 for HCO3, TCO2, BE, and SHCO3. These correlation coefficients, together with similar values in BE at all collection sites, indicate that, in the dog with normal circulatory status, blood from any venous site will accurately reflect the acid-base status of the patient.  相似文献   

2.
A hand-held lactate test device and a blood gas auto analyzer were compared. The objective of the study was to evaluate the performance of the hand-held device in dogs in a clinical setting. Blood lactate levels were evaluated on 30 samples from healthy client-owned dogs and 48 samples from client-owned dogs with various diseases. A blood sample was collected from each healthy dog by either jugular or cephalic venipuncture and from each sick dog from the jugular, cephalic, or saphenous vein, or from an arterial catheter if applicable. One and a half milliliters of the blood sample was immediately transferred to a heparinized vacutainer tube. Enough blood was then drawn from the heparinized tube to allow split sample simultaneous analysis with both machines. Samples from the sick dogs represented a wide range of clinically relevant lactate values. Good agreement between lactate values from both devices was obtained in both sick and healthy dogs. Lactate values in the healthy group (< 2.9 mmol/L with the hand-held device, < 2.6 mmol/L with the blood gas analyzer) were similar to those previously reported (< 2.5 mmol/L). The results of this study support the use of the hand-held device in dogs in a clinical setting.  相似文献   

3.
OBJECTIVE: To evaluate the analytical agreement between blood lactate concentrations determined by use of an enzymatic-amperometric bedside system in capillary blood samples from the pinna and in jugular venous blood samples from dogs. ANIMALS: 53 dogs. PROCEDURES: For each dog, venous and capillary blood samples were obtained from a jugular vein and from the ear pinna (by use of a lancing device), respectively, following a randomized sequence of collection. Lactate concentrations in both types of samples were analyzed by use of an enzymatic-amperometric bedside system intended for lactate detection in capillary blood samples from humans that was previously validated in dogs. The Passing-Bablock regression analysis was used to compare venous and capillary blood lactate concentrations; the level of agreement was calculated by use of the Bland-Altman method. RESULTS: Jugular venous blood samples were collected without difficulty from all 53 dogs. A capillary blood sample was obtained from only 47 dogs. The correlation coefficient between lactate concentrations measured in venous and capillary blood samples was 0.58 (slope, 2.0 [95% confidence interval, 1.5 to 3.0]; intercept, -1.2 [95% confidence interval, -3.1 to 0.4]). The mean difference between methods was 0.72 mmol/L (95% confidence interval, 0.38 to 1.06) with limits of agreement of -1.55 to 2.99 mmol/L. CONCLUSIONS AND CLINICAL RELEVANCE: Because of the lack of agreement between lactate concentrations determined in capillary and jugular venous blood samples, measurement of capillary blood lactate concentration in dogs performed with the technique used in the study does not appear to be a reliable alternative to jugular venous blood measurements.  相似文献   

4.
The aim of this study was to examine the effect of the sampling site on the drug concentration–time profile, following intravenous or buccal (often called ‘oral transmucosal’) drug administration. Buprenorphine (20 μg/kg) was administered IV or buccally to six cats. Blood samples were collected from the carotid artery and the jugular and medial saphenous veins for 24 h following buprenorphine administration. Buprenorphine concentration–time data were examined using noncompartmental analysis. Pharmacokinetic parameters were compared using the Wilcoxon signed rank test, applying the Bonferroni correction. Significance was set at P < 0.05. Following IV administration, no difference among the sampling sites was found. Following buccal administration, maximum concentration [jugular: 6.3 (2.9–9.8), carotid: 3.4 (1.9–4.9), medial saphenous: 2.5 (1.7–4.1) ng/mL], area under the curve [jugular: 395 (335–747), carotid: 278 (214–693), medial saphenous: 255 (188–608) ng·min/mL], and bioavailability [jugular: 47 (34–67), carotid: 32 (20–52), medial saphenous: 23 (16–55)%] were higher in the jugular vein than in the carotid artery and medial saphenous vein. Jugular venous blood sampling is not an acceptable substitute for arterial blood sampling following buccal drug administration.  相似文献   

5.
Serial plasma lactate concentrations in 68 puppies aged 4 to 80 days   总被引:1,自引:0,他引:1  
Objective: To determine a reference range for venous blood lactate concentrations in healthy neonatal dogs. Design: A prospective cohort study. Setting: All work was conducted at the College of Veterinary Medicine, Texas A&M University. Animals: Clinically healthy dogs: 68 puppies and 30 adults. Measurements and main results: A blood sample was collected from each puppy into lithium heparin via jugular venipuncture at 4, 10, 16, 28, 70, and 80 days of age. A single venous sample was collected from each adult dog. Lactate concentration in each sample was measured immediately using an automated analyzer. Two hundred seventy‐seven blood samples were analyzed. Blood lactate concentrations of adult dogs were 1.80±0.84 mmol/L (mean±SD). Mean blood lactate concentrations of puppies were significantly higher at 4, 10, 16, and 28 days of age compared with those of adult dogs. The reference range for lactate concentration for puppies at 4 days of age was 1.07–6.59, and for the puppies from 10 to 28 days of age was 0.80–4.60. Conclusions: Assessment of perfusion can be challenging in neonates due to normal physiologic variation and small size. Measurement of lactate is rapid, minimally invasive, and has potential to be a useful marker of perfusion in neonatal dogs. However, lactate concentrations of neonatal dogs in this study were significantly higher than those of adult dogs. Reference ranges for venous lactate concentrations in adult dogs should not be used for puppies younger than 70 days of age.  相似文献   

6.
Using paediatric devices to collect venous blood from a cephalic vein in cats offers numerous practical advantages over traditional jugular venepuncture and vacuum closed systems: minimal restraint is required; there is minimal risk of serious injury to the cat; the discomfort associated with venepuncture is reduced by the use of small diameter (25 gauge) needles; very small volumes (200 microl) of blood are extracted; and the risk of vein collapse or haematoma is low. The aim of this study was to compare the haematological and plasma chemistry results obtained from six healthy cats using the two sampling techniques. Five plasma biochemical analytes were measured and a complete haematological examination was performed on each specimen. No clinically relevant difference between the two blood sampling techniques was observed for any variable, indicating that paediatric devices provide a useful alternative to vacuum tubes for venous blood collection in the cat.  相似文献   

7.
BACKGROUND: Lactate concentrations are increasingly quantified in dogs using point-of-care instruments, but often without canine-specific method evaluation and instrument-specific reference intervals. OBJECTIVES: The objectives of this study were to 1) determine the precision of the Accutrend (Roche Diagnostics) for lactate determination in dogs, 2) determine the accuracy of the Accutrend using the Rapidlab 865 (Bayer Diagnostics) as the reference method, and 3) establish and compare reference intervals for lactate concentration in clinically healthy dogs for both instruments. METHODS: Precision was evaluated using low and high control materials, and variable (1 drop) and fixed (25 microL) sample volumes. Accuracy was determined by comparing lactate concentrations obtained with the Accutrend with those from the Rapidlab 865 in 273 heparinized canine jugular venous blood samples from 100 clinically healthy dogs and 107 systemically ill dogs (173 samples). Lactate reference intervals were established for both analyzers using data from the 100 clinically healthy dogs. RESULTS: The precision of the Accutrend was good (coefficients of variation, < or = 5.3%) for 25-microL samples but not when a drop was used. Lactate concentrations obtained on the Accutrend correlated poorly with those from the Rapidlab 865 (r = 0.864, mean bias = 0.66 mmol/L, 95% confidence interval [CI] = 0.57-0.76 with 95% limits of agreement = -0.87 (lower limit, 95% CI = -1.03 to -0.71) and 2.20 (upper limit, 95% CI = 2.04 to 2.36). The reference interval for canine lactate concentration on the Accutrend was 1.2-3.1 mmol/L compared with 0.46-2.31 mmol/L on the Rapidlab. CONCLUSION: Although precision was good with fixed sample volumes, blood lactate concentrations obtained on the Accutrend were significantly different than those on the Rapidlab 865, with systematic and random errors resulting in a positive bias. Further evaluation of the Accutrend is required before its use in dogs can be recommended.  相似文献   

8.
The effect of venipuncture on blood serum catecholamine concentrations was studied in five yearling Red Angus bulls. Treatments consisted of sampling jugular vein blood via indwelling cannulas in a squeeze chute every 10 min for 1 h; sampling jugular vein blood from an indwelling catheter before, during and after venipuncture simulation; sampling jugular vein blood by venipuncture in a chute after shipment of 320 km to a slaughter plant; and sampling pooled blood from the neck during exsanguination at slaughter. Plasma epinephrine (E) and norepinephrine (NE) concentrations were determined by high performance liquid chromatography (HPLC) with electrochemical detection (ECD). Prevenipuncture NE and E in blood sampled from an indwelling catheter extended through a solid wall were 1.0 and .5 pmol/ml plasma, respectively. Plasma NE and E during venipuncture (1.6 and 1.1 pmol/ml, respectively) and immediately after cannulation in a squeeze chute (1.8 and 1.2 pmol/ml, respectively) were higher than prevenipuncture concentrations. Plasma NE and E, 1.9 and 1.2 pmol/ml plasma after shipment of 320 km, increased during exsanguination to 135.8 and 81.3 pmol/ml plasma, respectively. The NE and E in blood samples collected by venipuncture in a chute or box stall do not represent resting concentrations of these catecholamines.  相似文献   

9.
Previous studies have shown that regional limb perfusion (RLP) using the palmar digital (PD) vein delivers therapeutic concentration of amikacin to the distal limb. Our hypothesis was that using the cephalic and saphenous veins for RLP will enable delivery of therapeutic concentrations of amikacin to the distal limb. Nineteen healthy horses participated in the study. The cephalic, saphenous, or PD vein was used to perfuse the limb with amikacin. Two grams of amikacin was used for RLP using the saphenous and the cephalic veins, and one gram was used in the PD vein. Synovial samples were collected from the metacarpo‐/metatarsophalangeal (MCP/MTP) joint, and blood samples were collected from the jugular vein. Maximum concentration (Cmax) of amikacin in the MCP/MTP joint using the cephalic and the saphenous vein was 277 and 363 mg/L, respectively. The amikacin concentrations achieved in the synovial fluid of the MCP/MTP joint in the current study were between 69 and 91 times the minimally inhibitory concentration of common susceptible bacterial pathogens causing orthopedic infections in horses. To conclude, this study shows that use of the proximal veins for RLP to treat distal limb infections is a viable alternative to using the palmar or plantar digital vein.  相似文献   

10.
OBJECTIVES: The objective of this study was to determine the accuracy of the Lactate Pro hand-held analyser in measuring blood lactate levels. METHODS: Blood was drawn from 15 healthy dogs into five tubes containing Na-EDTA. Lactate was measured immediately using the Lactate Pro analyser and a laboratory reference method. Further samples were analysed 120, 240, 480 and 1440 minutes later to artificially increase the lactate levels. Lactate was measured in blood samples of 60 healthy dogs using the Lactate Pro analyser to determine the reference interval of lactate concentration in normal dogs. RESULTS: The correlation between the lactate concentration measured with the Lactate Pro analyser and the reference method was high. Lactate levels were lower when measured with the hand-held analyser than with the traditional laboratory determination. The reference interval for blood lactate concentrations in healthy dogs established by the Lactate Pro analyser was from the detection limit (0.8 mmol/l) up to 3.3 mmol/l. CLINICAL SIGNIFICANCE: The Lactate Pro analyser provides quick and reliable measurements of blood lactate in dogs with blood lactate levels up to 10 mmol/l. Because of its small sample size, this analyser will be particularly appropriate for use in small animal intensive care.  相似文献   

11.
AIM: To examine cardiovascular, hormonal and other physiological responses of 2-month-old lambs to rubber-ring castration and tail docking. METHODS: Twenty-two male lambs, well accustomed to handling and prepared with femoral artery and jugular vein cannulae, were studied during a 5 h control period and, at least 2 days later, for 1 h before and 4 h after castration and tail docking using rubber rings. Pressure recordings were made via femoral cannulae and blood samples for analysis of plasma constituents were taken from jugular cannulae. RESULTS: Mean systolic, diastolic and mean arterial blood pressure, heart rate and the plasma concentrations of adrenocorticotropic hormone (ACTH) and cortisol all increased markedly during the first 1 h after ring castration and tail docking. Although plasma ACTH and cortisol concentrations had returned to control levels by 2.5-3 h, blood pressures and heart rate were still elevated 4 h after ring application. In contrast, there were no significant changes in mean plasma concentrations of renin, electrolytes, minerals, glucose, lactate, urea, creatinine, total carbon dioxide and total proteins, plasma osmolality or the haematocrit after ring application. There were no significant changes in the mean values for any parameter during the 5 h control period or the 1 h period before ring application. CONCLUSION: Systolic, diastolic and mean arterial blood pressure and heart rate may be more sensitive than plasma ACTH or cortisol concentrations as indices of low-grade pain induced by ring castration and tail docking. Alternatively, it is possible that by 4 h after ring placement a small shift in sympathetic tone still persists in the absence of low-grade pain.  相似文献   

12.
BACKGROUND: The clinical implications of evaluating C-terminal atrial natriuretic peptide (ANP) concentration in cats are still controversial. HYPOTHESIS: The objective of this study was to investigate the relationship between plasma C-terminal ANP concentration and left atrial pressure (LAP) in healthy cats with volume overload (study 1), and to compare plasma C-terminal ANP in normal cats and cats with cardiomyopathy (study 2). ANIMALS: Five healthy adult cats were used in study 1, and clinically healthy cats (n=8) and cats with cardiomyopathy (n=14) were used in study 2. METHODS: In study 1, cats were anesthetized and given acetated Ringer's solution (100 mL/kg/h for 60 minute) via the cephalic vein. Hemodynamic measurements and blood samples, collected from the jugular vein, were performed at 10-min intervals. In study 2, blood samples from normal cats and cats with cardiomyopathy were collected from the cephalic vein. The plasma C-terminal ANP concentration was determined by radioimmunoassay for human alpha-ANP. RESULTS: In study 1, volume overload significantly increased the C-terminal ANP concentration and LAP from baseline. The C-terminal ANP concentration was strongly correlated with the mean LAP. In study 2, age, E wave velocity, and the ratios of the left atrium to aorta were significantly higher in the cats with cardiomyopathy compared with the normal cats. The C-terminal ANP concentration was significantly higher in the cats with cardiomyopathy compared with the normal cats. CONCLUSIONS AND CLINICAL IMPORTANCE: Our results suggest that the measurement of plasma C-terminal ANP in cats may provide additional information for the diagnosis of heart disease.  相似文献   

13.
OBJECTIVE: To investigate penetration of a topically applied nonsteroidal anti-inflammatory drug (NSAID) into tissues and synovial fluid. ANIMALS: 5 Greyhounds. PROCEDURE: Dogs were anesthetized and microdialysis probes placed in the dermis and gluteal muscle over each coxofemoral (hip) joint. Methylsalicylate (MeSA) was applied topically over the left hip joint. Dialysate and plasma (blood samples from the cephalic and femoral veins) were obtained during the subsequent 5 hours. Dogs were euthanatized, and tissue samples and synovial fluid were collected and analyzed for salicylic acid (SA) and MeSA by use of high-pressure liquid chromatography. RESULTS: SA and MeSA concentrations increased rapidly (< 30 minutes after application) in dialysate obtained from treated dermis. Salicylic acid also appeared in plasma within 30 minutes and reached a plateau concentration after 2 hours, although combined drug concentrations (SA plus MeSA) in plasma obtained from femoral vein samples were twice those measured in plasma obtained from the cephalic vein (SA only). Treated muscle had a progressive decrease in NSAID concentration with increasing depth (SA and MeSA), but it was significantly higher than the concentration in untreated muscle. Substantial amounts of SA and MeSA were also measured in synovial fluid of treated joints. CONCLUSIONS AND CLINICAL RELEVANCE: Topically applied NSAIDs can penetrate deeply into tissues and synovial fluid. Local concentrations higher than circulating systemic concentrations are suggestive that direct diffusion and local blood redistribution are contributing to this effect. Systemic blood concentrations may be inadequate to describe regional kinetics of topically applied drugs.  相似文献   

14.
OBJECTIVE: To establish a reliable diagnostic tool for septic peritonitis in dogs and cats using pH, bicarbonate, lactate, and glucose concentrations in peritoneal fluid and venous blood. STUDY DESIGN: Prospective clinical study. ANIMALS: Eighteen dogs and 12 cats with peritoneal effusion. METHODS: pH, bicarbonate, electrolyte, lactate, and glucose concentrations were measured on 1- to 2-mL samples of venous blood and peritoneal fluid collected at admission. The concentration difference between blood and peritoneal fluid for pH, bicarbonate, glucose, and lactate concentrations were calculated by subtracting the peritoneal fluid concentration from the blood concentration. Peritoneal fluid was submitted for cytologic examination and bacterial culture. Peritonitis was classified as septic or nonseptic based on cytology and bacterial culture results. RESULTS: In dogs, with septic effusion, peritoneal fluid glucose concentration was always lower than the blood glucose concentration. A blood-to-fluid glucose (BFG) difference > 20 mg/dL was 100% sensitive and 100% specific for the diagnosis of septic peritoneal effusion in dogs. In 7 dogs in which it was evaluated, a blood-to-fluid lactate (BFL) difference < -2.0 mmol/L was also 100% sensitive and specific for a diagnosis of septic peritoneal effusion. In cats, the BFG difference was 86% sensitive and 100% specific for a diagnosis of septic peritonitis. In dogs and cats, the BFG difference was more accurate for a diagnosis of septic peritonitis than peritoneal fluid glucose concentration alone. CONCLUSIONS: A concentration difference > 20 mg/dL between blood and peritoneal fluid glucose concentration provides a rapid and reliable means to differentiate a septic peritoneal effusion from a nonseptic peritoneal effusion in dogs and cats. CLINICAL RELEVANCE: The difference between blood and peritoneal fluid glucose concentrations should be used as a more reliable diagnostic indicator of septic peritoneal effusion than peritoneal fluid glucose concentration alone.  相似文献   

15.
BACKGROUND: Measurement of blood lactate concentration has become a common practice in canine medicine. However, the accuracy of portable lactate monitors has not been reported in dogs. OBJECTIVES: The aim of this study was to evaluate the accuracy and precision of a portable analyzer (Lactate-Scout) in measuring canine blood lactate concentration. METHODS: A preliminary study was performed to assess the effects of sample storage time and temperature on plasma lactate concentration. Blood samples obtained from 6 canine patients at our hospital were divided into 8 aliquots and stored at 4 degrees C and 20 degrees C; plasma lactate was measured in duplicate with a spectrophotometric system (Konelab) at 0, 30, 60, 120, and 240 minutes after the blood collection. Values were compared with those obtained immediately after blood collection. Lactate values obtained by the portable method also were compared with those obtained by the reference spectrophotometric analyzer on blood samples collected from 48 additional canine patients. RESULTS: There was no significant effect of storage time (P = .89) or temperature (P = .51) on plasma lactate levels. The correlation between lactate values measured with the Lactate-Scout and the Konelab method was r = .98 (slope = .81, 95% confidence interval = .73-.87; intercept = .20, 95% confidence interval = .13-.31). The level of agreement between the 2 methods was generally good for mean lactate concentrations <5 mmol/L. However, at higher lactate concentrations (5 of 48 samples), the values recorded by the Lactate-Scout analyzer were lower than those measured by the Konelab method. CONCLUSION: The Lactate-Scout analyzer is reliably comparable to a reference method for measuring whole blood lactate concentration in dogs; however, caution should be used when interpreting lactate values of 5 mmol/L and higher.  相似文献   

16.
Current methods for obtaining venous blood from the reproductive organs of livestock often have a low rate of success or involve intensive surgical procedures that may impair ovarian function. Therefore, the caudal vena cava was catheterized via the lateral saphenous vein to determine the feasibility of using this method for chronic sampling of blood draining from the reproductive organs of ewes (n = 6), cows (n = 6), and gilts (n = 7). Blood samples were collected at 2-cm (ewes and gilts) or 5-cm (cows) intervals during insertion of catheters. Correct placement, defined as the position at which plasma concentrations of progesterone or estrogen were at least threefold greater than in jugular venous plasma, varied among species and among animals within species. It seemed, however, that a majority of catheters would be placed correctly if secured at 48 to 52 cm in ewes, 52 cm in gilts, and 90 to 100 cm in cows. Saphenous vein catheters were secured for sequential sampling of vena caval blood during the follicular phase of ewes (n = 25), cows (n = 4), and gilts (n = 5). Catheters remained patent for the duration of sampling in all individuals. Concentrations of estrogen in jugular and vena caval plasma were correlated (ewe P less than .0003; cow P less than .0001; gilt P less than .0001). Profiles of progesterone and estrogen revealed an episodic pattern of secretion in vena caval but not jugular plasma. Catheterization of the vena cava via the saphenous vein is a relatively simple and noninvasive method for obtaining blood containing uterine and ovarian hormones before their metabolism.  相似文献   

17.
Four healthy, fully conscious, 50- to 80-kg Yucatan miniature swine were fitted with carotid artery and jugular, portal, and hepatic vein catheters and hepatic artery and portal vein flow cuffs to determine transhepatic kinetics and insulin secretion. Three days later, after a 3-hour control period, the pigs were given IV sodium dichloroacetate (30 mg/kg of body weight as a bolus and 30 mg/kg/hr, as an infusion) for 6 hours. Arterial lactate concentrations decreased during the dichloroacetate infusion, but pyruvate concentrations were unaltered. The whole body rate of appearance and disappearance of glucose decreased, but plasma glucose concentrations did not change markedly. Limb skin surface temperatures increased, indicating a peripheral vasodilatory effect. Dichloroacetate had little effect on mean arterial pressure and hepatosplanchnic blood flow. Dichloroacetate may be effective as a hypolactatemic agent for lactic acidosis in pigs.  相似文献   

18.
BACKGROUND: Hypophosphatemia is a condition that affects feed intake and milk production in dairy cows, and, to assess it, a precise biological parameter is needed. Plasma inorganic phosphate (Pi) can be used as a potential indicator of bioavailability of feed phosphorus in dairy cows. OBJECTIVE: The purpose of this study was to evaluate the effects of sample type (serum vs. plasma), blood sampling site (jugular vs. coccygeal), and morning feeding on blood Pi concentration in dairy cows. METHODS: Blood samples from 28 clinically healthy multiparous Holstein cows were analyzed for Pi concentration. The animals were sampled twice by coccygeal vessel into Vacutainer tubes both with and without sodium heparin, 3 hours after the morning feeding. In 4 additional cows, the concentration of Pi was measured in blood samples obtained simultaneously by jugular and coccygeal venipuncture into heparinized tubes before the morning feeding and 2, 4, and 6 hours after the feeding. The results were analyzed using parametric statistical tests. RESULTS: Serum and plasma concentrations of Pi were correlated (r(2) = 0.999, P < .0001), but serum Pi concentration was higher than plasma Pi (P < .02). Plasma Pi concentration 2 hours after feeding tended to be higher than that before feeding in jugular samples, but the difference was not significant. There was no significant variation in plasma Pi during the morning postfeeding times, although jugular concentrations were 19% lower than coccygeal (P = .04). CONCLUSION: To increase the precision of plasma Pi measurements as an indicator of bioavailability of feed phosphorus, sample type, sampling time, and site must be taken into account, to correctly interpret plasma Pi concentrations.  相似文献   

19.
OBJECTIVE: To determine values for the total concentration of nonvolatile weak acids (Atot) and effective dissociation constant of nonvolatile weak acids (Ka) in plasma of cats. SAMPLE POPULATION: Convenience plasma samples of 5 male and 5 female healthy adult cats. PROCEDURE: Cats were sedated, and 20 mL of blood was obtained from the jugular vein. Plasma was tonometered at 37 degrees C to systematically vary PCO2 from 8 to 156 mm Hg, thereby altering plasma pH from 6.90 to 7.97. Plasma pH, PCO2, and concentrations of quantitatively important strong cations (Na+, K+, and Ca2+), strong anions (Cl-, lactate), and buffer ions (total protein, albumin, and phosphate) were determined. Strong ion difference was estimated from the measured strong ion concentrations and nonlinear regression used to calculate Atot and Ka from the measured pH and PCO2 and estimated strong ion difference. RESULTS: Mean (+/- SD) values were as follows: Atot = 24.3 +/- 4.6 mmol/L (equivalent to 0.35 mmol/g of protein or 0.76 mmol/g of albumin); Ka = 0.67 +/- 0.40 x 10(-7); and the negative logarithm (base 10) of Ka (pKa) = 7.17. At 37 degrees C, pH of 7.35, and a partial pressure of CO2 (PCO2) of 30 mm Hg, the calculated venous strong ion difference was 30 mEq/L. CONCLUSIONS AND CLINICAL RELEVANCE: These results indicate that at a plasma pH of 7.35, a 1 mEq/L decrease in strong ion difference will decrease pH by 0.020, a 1 mm Hg decrease in PCO2 will increase plasma pH by 0.011, and a 1 g/dL decrease in albumin concentration will increase plasma pH by 0.093.  相似文献   

20.
M. Werner  C. Gallo   《Livestock Science》2008,115(1):94-98
The aim of the present study was to determine, in horses destined to slaughter, the effects of transport, lairage and stunning on some blood constituents related to stress. Twenty one horses culled from a race track due to poor athletic performance, transported weekly to a nearby slaughterhouse were used. Each horse was canulated through venipuncture of the right jugular vein with a central venous catheter which remained permanently until after the exsanguination. Through the catheter, blood samples were taken at 6 sampling times: one hour before loading of the horses, immediately after loading, at the end of the journey, immediately after unloading, after lairage, in the stunning box before stunning and during exsanguination. Blood samples were analyzed for the following variables: plasma lactate concentration, plasma creatine phosphokinase activity (CK), plasma glucose concentration, plasma cortisol concentration and packed cell volume (PCV). Time in the stunning box, number of stunning attempts, presence of return to consciousness signs and time between stunning and sticking were also recorded. The results for pre-mortem variables were: mean time in the stunning box 9 min 48 sec, 85.7% of the horses fell at the first stunning attempt, 57.2% of the horses showed signs of returning to consciousness after stunning and the most frequent interval between stunning and sticking was 1.01 to 2 min. Mean values for the blood variables showed a significant rise (P < 0.05) in the concentrations of lactate, glucose and cortisol, as well as CK activity and PCV during transport. The highest values for these blood constituents were seen before stunning and during exsanguination, except for cortisol concentration, which showed the highest values during the transport process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号