首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A conventional high‐resolution screen–film system was compared with a digital detector system. A total of 20 birds (14 pigeons and six psittacine birds) with an average body mass of 533 g were examined in dorsoventral as well as lateral projections. Digital radiographs were acquired with the same mAs as well as half the mAs used for the conventional radiographs. Three criteria and one overall assessment were defined for each of four anatomic regions and assessed by five veterinarians using a score system. Comparison of the ratings was done by visual grading analysis. For the majority of criteria, there was no significant difference regarding image quality between the digital and screen–film projections. However, for certain criteria the quality of the digital images was significantly superior. Using the same mAs as for the conventional radiographs, the humeral joint surfaces and the honeycomb structure of the lung were assessed as superior with the digital imaging system. The tracheal rings and the delineation of the trachea from the surrounding tissue were also superior with the digital system. Assessment of the trabecular structure of the humerus was superior when the full mAs was used compared with the reduced mAs. In conclusion the digital technique is equal or superior to the conventional screen–film high‐resolution system for pet birds of a medium size. With some limitations, a dose reduction is possible with the digital system.  相似文献   

2.
Radiographic diagnosis of equine bone disease using digital radiography is prevalent in veterinary practice. However, the diagnostic quality of digital vs. conventional radiography has not been compared systematically. We hypothesized that digital radiography would be superior to film-screen radiography for detection of subtle lesions of the equine third metacarpal bone. Twenty-four third metacarpal bones were collected from horses euthanized for reasons other than orthopedic disease. Bones were dissected free of soft tissue and computed tomography was performed to ensure that no osseous abnormalities were present. Subtle osseous lesions were produced in the dorsal cortex of the third metacarpal bones, and the bones were radiographed in a soft tissue phantom using indirect digital and conventional radiography at standard exposures. Digital radiographs were printed onto film. Three Diplomates of the American College of Veterinary Radiology evaluated the radiographs for the presence or absence of a lesion. Receiver operator characteristic curves were constructed, and the area under these curves were compared to assess the ability of the digital and film-screen radiographic systems to detect lesions. The area under the ROC curves for film-screen and digital radiography were 0.87 and 0.90, respectively ( P =0.59). We concluded that the digital radiographic system was comparable to the film-screen system for detection of subtle lesions of the equine third metacarpal bone.  相似文献   

3.
A better understanding of imaging characteristics of equine stifle osteoarthritis (OA) may allow earlier detection and improve prognosis. Objectives of this ex vivo, prospective, methods comparison study were to (1) describe the location and severity of naturally acquired OA lesions in the equine stifle using ultrasound (US), radiography (XR), computed tomography (CT), and macroscopic evaluation (ME); (2) compare the diagnostic performance of each imaging modality with ME; and (3) describe subchondral bone mineral density (BMD) in equine stifle joints with OA using CT. Radiographic, CT, and US evaluations were performed on 23 equine cadaver stifles and compared with ME. Significant associations were found between osteophyte global scores for all imaging modalities (CT, P ? 0.0001; XR, P = 0.005; US, P = 0.04) vs. ME osteophyte global scores. Osteophytes were detected most frequently in the medial femorotibial (MFT) joint. A specific pattern of osteophytes was observed, with a long ridge of new bone at the insertion of the MFT joint capsule cranially on the medial femoral condyle. A novel caudo‐10°proximo‐5°lateral‐cranio‐disto‐medial oblique radiographic projection was helpful for detection of intercondylar osteophytes. Multiplanar CT reformatted images were helpful for characterizing all osteophytes. Osteophyte grades at most sites did not differ among modalities. Low sensitivity/specificity for subchondral bone sclerosis and flattening of femoral condyles suggested that these signs may not be reliable radiographic and CT indicators of equine stifle OA. Equine stifle OA was associated with a decrease in BMD and specific sites of focal subchondral bone resorption/cyst formation were found in some specimens.  相似文献   

4.
Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.  相似文献   

5.
The purpose of this study was to define normal gross anatomic structures in the equine stifle with magnetic resonance images. Magnetic resonance (MR) images were made in sagittal, 15° supinated, transverse, and dorsal planes of two equine stifles. The MR images were scrutinized by comparing MR images to dissection specimens and frozen cross sections of stifle joints. Sagittal and 15° supinated images were the most valuable in assessing articular cartilage, subchondral bone, and soft tissue structures within the joint. Cranial and caudal cruciate ligaments, medial and lateral menisci, meniscotibial and meniscofemoral ligaments, long digital extensor tendon, and patellar ligaments were easily evaluated. MR images provided substantially more gross anatomical information than the currently available imaging modalities.  相似文献   

6.
Radiographic evaluation of the entire adult equine thorax in the standing position requires a minimum of four overlapping lateral radiographs. Small horses could often be studied with fewer radiographs. This basic examination provided the optimal radiographic opportunity for detecting lung diseases in the horse. An understanding of normal gross and radiographic anatomy is an absolute necessity if one is to avoid the potential diagnostic pitfalls inherent in radiographic interpretation of the equine thorax. Of equal importance is an appreciation for the technic required to produce thoracic radiographs. The advent of rare-earth intensifying screen and highspeed film systems has enhanced the opportunity for obtaining diagnostic standing lateral equine thoracic radiographs.  相似文献   

7.
We compared the information gained from computed tomography (CT) vs. radiography in horses with nonneoplastic disease of the mandible. We hypothesized that CT would provide additional diagnostic information. Medical records, radiographs, and CT images of horses with nonneoplastic mandibular disease evaluated between 1994 and 2008 were reviewed. Nineteen horses were identified; 11 had a tooth root abscess and related disease, four had a fracture of the teeth and/or mandible, and four had a nonneoplastic mass. Both CT images and radiographs allowed identification of diseased teeth that appeared clinically normal otherwise. CT allowed identification of teeth that were clinically affected but appeared normal radiographically. Parameters such as tooth pulp involvement, lamina dura destruction, presence of bone fragments, lingual and buccal mandibular bone periosteal reaction, and cortical bone destruction were more conspicuous with CT. Performing radiography and CT in horses with nonneoplastic mandibular disease provides a more complete evaluation than either technique alone. CT contributes additional information that could otherwise be overlooked with radiographs alone in horses with a mandibular fracture. CT provides ancillary information to radiographs in horses with dental infection or a nonneoplastic mass of the mandible.  相似文献   

8.
This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath.
The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria , 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons.  相似文献   

9.
Disorders of the stifle are a common cause of lameness in horses yet the accuracy of scintigraphy for diagnosis of stifle conditions is controversial. The aim of retrospective cross‐sectional study was to determine the diagnostic sensitivity (Se) of bone scintigraphy in detecting stifle disease and to determine if two orthogonal scintigraphic images improve diagnostic Se. Horses that underwent scintigraphic examination during a two‐year period were included. Horses were divided into two groups: group 1 (N = 23) had lameness that was localized to the stifle by intra‐articular analgesia and group 2 (N = 182) had lameness that was localized to a different location. Scintigraphic studies (one image or two images) were independently and retrospectively analyzed by two radiologists (R1 and R2). Sensitivity, specificity (Sp) and predictive values (PV), and were calculated for each type of study (one image or two images) and for each radiologist (R1 or R2). The Se to detect stifle disorders varied between radiologists (29.2% and 20.8%). The Sp was 84.5% and 88.3%. When two images were evaluated a decrease in the positive PV for both readers occurred. The Cohen kappa coefficient (κ) between readers was poor when one image (0.084) or two images (0.117) were evaluated. Findings from this study indicated that bone‐phase nuclear scintigraphy is reasonably specific but highly insensitive for detecting lameness originating from the stifle in a diverse population of both normal and affected horses. The addition of a caudal scintigraphic image acquisition did not improve diagnostic sensitivity.  相似文献   

10.
The construction of a variable kVp, variable mA radiographic technique chart for the equine thorax using linear regression analysis is described. The independent variables in the analysis were body weight (pounds) and thoracic girth (inches) and the dependent variables were the radiographic exposure techniques (mAs, kV.p). Four areas (lateral views only) of each horse's thorax were radiographed using a focal spot-film distance (FFD) of 200 cm with the animal standing. The four views were craniodorsal, cranioventral, caudodorsal and caudoventral. For comparison, an additional caudodorsal view was made at 100 cm FFD to quantitate the decrease in exposure, the increased magnification and the decreased area of the lung exposed on the x-ray tube side of the horse compared with 200 cm FFD technique. Body weight was a satisfactory means to determine radiographic technique factors for thoracic radiographs in the horse. Thoracic girth (inches) was also measured and used to determine radiographic technique factors but was less exacting and less convenient than body weight.  相似文献   

11.
In human medical imaging, the performance of the monitor used for image reporting has a substantial impact on the diagnostic performance of the entire digital system. Our purpose was to compare the display quality of different monitors used in veterinary practice. Two medical‐grade gray scale monitors (one cathode‐ray tube [CRT], one liquid crystal display [LCD]) and two standard consumer‐grade color monitors (one CRT, one LCD) were compared in the ability to display anatomic structures in cats. Radiographs of the stifle joint and the thorax of 30 normal domestic shorthair cats were acquired by use of a storage phosphor system. Two anatomic features of the stifle joint and five anatomic structures of the thorax were evaluated. The two medical‐grade monitors had superior display quality compared with standard PC monitors. No differences were seen between the monochrome monitors. In comparison with the color CRT, the ratings of the color LCD were significantly worse. The ranking order was uniform for both the region and the criteria investigated. Differences in monitor luminance, bit depth, and screen size were presumed to be the reasons for the observed varying performance. The observed differences between monitors place an emphasis on the need for guidelines defining minimum requirements for the acceptance of monitors and for quality control in veterinary radiography.  相似文献   

12.
It is not always possible to identify female cats that have undergone previous ovariohysterectomy based on physical examination alone. An easy, cost‐effective method for screening female cats for reproductive status would be helpful for avoiding unnecessary exploratory laparotomies. The purpose of this prospective study was to compare diagnostic sensitivities of digital radiography, ultrasonography, and positive contrast vaginourethrography for determining reproductive status in female cats. Sixty‐seven recently euthanized female cats of unknown medical history and reproductive status were randomly selected and included in the study. Digital abdominal radiography, digital abdominal radiography with compression, abdominal ultrasonography, and positive contrast vaginourethrography were performed in sequence by a board‐certified veterinary radiologist and a second‐year radiology resident. Immediately following diagnostic imaging procedures, necropsy was performed. Ultrasonography of the uterus had the highest sensitivity (86%) for determining reproductive status of all the imaging modalities tested. The specificity was 88%, and the positive predictive value and negative predictive value were 96% and 68%, respectively. The calculated sensitivities and specificities of other modalities were as follows: digital radiographs (28%, 100%), digital compression radiographs (58%, 100%), and vaginourethrography (32%, 100%). Based on McNemar's test statistic, there was a significant difference in the sensitivity of ultrasound compared to digital radiographs (P ≤ 0.05), compression radiographs (P ≤ 0.05), and vaginourethrogram (P ≤ 0.05). Findings from the current study indicated that ultrasonography is a sensitive diagnostic test for determining reproductive status in female cats. Although more readily available in private practice and shelters, digital radiography and vaginourethrography are not reliable predictors of reproductive status.  相似文献   

13.
William R.  Widmer  DVM  MS  Kenneth A.  Buckwalter  MD  MS  John F.  Fessler  DVM  MS  Michael A.  Hill  B Vet  Med  MS  PhD  MRCVS  David C.  Vansickle  DVM  PhD  Susan  Ivancevich  MD 《Veterinary radiology & ultrasound》2000,41(2):108-116
Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.  相似文献   

14.
The widths of spaces between the thoracolumbar processi spinosi (interspinous spaces) are frequently assessed using radiography in sports horses; however effects of varying X‐ray beam angles and geometric distortion have not been previously described. The aim of this prospective, observational study was to determine whether X‐ray beam angle has an effect on apparent widths of interspinous spaces. Thoracolumbar spine specimens were collected from six equine cadavers and left‐right lateral radiographs and sagittal and dorsal reconstructed computed tomographic (CT) images were acquired. Sequential radiographs were acquired with each interspinous space in focus. Measurements were performed for each interspinous space in the focus position and up to eight angled positions as the interspinous space moved away from focus (±). Focus position measurements were compared to matching sagittal CT measurements. Effect of geometric distortion was evaluated by comparing the interspinous space in radiographs with sagittal and dorsal reconstructed CT images. A total of 49 interspinous spaces were sampled, yielding 274 measurements. X‐ray beam angle significantly affected measured width of interspinous spaces in position +3 (P = 0.038). Changes in width did not follow a consistent pattern. Interspinous space widths in focus position were significantly smaller in radiographs compared to matching reconstructed CT images for backs diagnosed with kissing spine syndrome (P < 0.001). Geometric distortion markedly affected appearance of interspinous space width between planes. In conclusion, X‐ray beam angle and geometric distortion influence radiographically measured widths of interspinous spaces in the equine thoracolumbar spine, and this should be taken into consideration when evaluating sport horses.  相似文献   

15.
REASONS FOR PERFORMING STUDY: Radiography is a very important aspect of equine stifle imaging. The precise radiographic anatomy of the soft tissue structures of the equine stifle has not been described previously. OBJECTIVE: To describe the anatomical relationship between sites of attachment of soft tissue structures of the equine stifle and their locations on standard radiographic views. METHODS: The sites of bony attachments of the tendons, ligaments and fibrous portion of the joint capsules of equine stifles were determined by gross dissection. These sites of attachment were transposed onto one set of bones deprived of soft tissue and mapped using radiopaque markers. This specimen was then radiographed in the standard radiographic projections (lateromedial, caudocranial and caudal 60 degrees lateral-craniomedial oblique) to determine the position of the attachment sites on the radiographs. RESULTS: Two radiographic maps were drawn per radiographic projection, one for the attachment sites of the ligaments and tendons and one for the attachment sites of the joint capsules. CONCLUSIONS AND POTENTIAL RELEVANCE: The radiographic maps of the precise position of the soft tissue attachments of the tendons, ligaments and joint capsules of the equine stifle should assist interpretation of equine stifle radiographs.  相似文献   

16.
Medial patellar desmotomy has been considered a benign surgical treatment in horses with suspected upward fixation of the patella. Our clinic has previously observed radiographic changes in the equine stifle following medial patellar desmotomy but preoperative radiographs were not made and the changes therefore could not be directly associated with the desmotomy. In this report we describe a case with normal stifle radiographs before medial patellar desmotomy. Radiographs made 3 months later demonstrated degeneration of the patella with enthesophytes, osteolysis and bone fragments. It is hypothesized that the lesion developed as a result of lateral rotation of the patella creating stress concentration in the subchondral bone of the distal articular surface of the patella. The pathogenesis of the patellar lesion is thought to be similar to the "gull wing" lesion on the distal palmar aspect of the third metacarpal bone. We recommend a more prudent approach to medial patellar desmotomy in the horse.  相似文献   

17.
The utility of magnetic resonance (MR) imaging in the evaluation of equine solar foot penetrations is well established. The objective of this pilot study was to evaluate the utility of MR imaging in assessment of equine distal limb wounds excluding solar penetrations. Low-field MR images of 23 horses that had previously sustained distal limb wounds were reviewed in consensus by two ECVDI diplomats. Structures (bone; synovial structure; subcutaneous tissue and skin; and ligament/tendon) were identified as normal or abnormal on MR images, radiographs and ultrasound images and reports. All abnormalities were described. The presence of artefacts and their effect on image interpretation were also noted for each modality. Comparisons were made between imaging modalities, and it was noted if MR imaging influenced case management. Abnormalities of the bone were identified in 26% of horses on MR images and 17% of horses on radiographs; there were no osseous abnormalities identified on radiographs that were not identified on MR images, and additional features and better characterisation of lesions were noted on MR images. Tendon/ligament abnormalities were identified in 57% horses on MR and 47% of horses on ultrasound images. Magnetic susceptibility artefacts compromised MR image interpretation in 17% of horses. MR imaging of equine distal limb wounds allowed identification of both osseous and tendon/ligament abnormalities in more cases than either radiography or ultrasonography, and altered case management in 20/23 horses. Although MR imaging should not replace conventional imaging, this study highlights that MR imaging of equine distal limb wounds can yield information not detected on conventional imaging which may direct treatment and affect prognostication.  相似文献   

18.
Understanding radiographic anatomy and the effects of varying patient and radiographic tube positioning on image quality can be a challenge for students. The purposes of this study were to develop and validate a novel technique for creating simulated radiographs using computed tomography (CT) datasets. A DICOM viewer (ORS Visual) plug‐in was developed with the ability to move and deform cuboidal volumetric CT datasets, and to produce images simulating the effects of tube‐patient‐detector distance and angulation. Computed tomographic datasets were acquired from two dogs, one cat, and one horse. Simulated radiographs of different body parts (n = 9) were produced using different angles to mimic conventional projections, before actual digital radiographs were obtained using the same projections. These studies (n = 18) were then submitted to 10 board‐certified radiologists who were asked to score visualization of anatomical landmarks, depiction of patient positioning, realism of distortion/magnification, and image quality. No significant differences between simulated and actual radiographs were found for anatomic structure visualization and patient positioning in the majority of body parts. For the assessment of radiographic realism, no significant differences were found between simulated and digital radiographs for canine pelvis, equine tarsus, and feline abdomen body parts. Overall, image quality and contrast resolution of simulated radiographs were considered satisfactory. Findings from the current study indicated that radiographs simulated using this new technique are comparable to actual digital radiographs. Further studies are needed to apply this technique in developing interactive tools for teaching radiographic anatomy and the effects of varying patient and tube positioning.  相似文献   

19.
ULTRASONOGRAPHY OF THE EQUINE STIFLE   总被引:3,自引:0,他引:3  
Ten stifles from 5 clinically sound adult horses were scanned by high-resolution ultrasound. Normal anatomic structures seen consistently included the subcutaneous tissue, the medial, middle and lateral patellar ligaments, the medial and lateral collateral ligaments, the femoral trochlear ridges, and menisci. Cruciate ligaments could not be visualized in the standing horse. Four stifle specimens obtained from 2 of these normal horses at necropsy were scanned in a water bath to create optimal technical conditions. The sonographic appearance of stifle specimens was similar to that found in live horses. Results from ultrasonographic examination of 3 horses with stifle abnormalities were described to illustrate some applications of ultrasonography in the evaluation of the equine stifle. In these horses, ultrasound was a valuable diagnostic tool to study joint effusion, synovial thickening, articular cartilaginous and subchondral defects, and soft tissue/bony injuries.  相似文献   

20.
Susceptibility artifacts caused by ferromagnetic implants compromise magnetic resonance imaging (MRI) of the canine stifle after tibial plateau leveling osteotomy (TPLO) procedures. The WARP‐turbo spin echo sequence is being developed to mitigate artifacts and utilizes slice encoding for metal artifact reduction. The aim of the current study was to evaluate the WARP‐turbo spin echo sequence for imaging post TPLO canine stifle joints. Proton density weighted images of 19 canine cadaver limbs were made post TPLO using a 3 Tesla MRI scanner. Susceptibility artifact sizes were recorded and compared for WARP vs. conventional turbo spin echo sequences. Three evaluators graded depiction quality for the tibial tuberosity, medial and lateral menisci, tibial osteotomy, and caudal cruciate ligament as sufficient or insufficient to make a diagnosis. Artifacts were subjectively smaller and local structures were better depicted in WARP‐turbo spin echo images. Signal void area was also reduced by 75% (sagittal) and 49% (dorsal) in WARP vs. conventional turbo spin echo images. Evaluators were significantly more likely to grade local anatomy depiction as adequate for making a diagnosis in WARP‐turbo spin echo images in the sagittal but not dorsal plane. The proportion of image sets with anatomic structure depiction graded adequate to make a diagnosis ranged from 28 to 68% in sagittal WARP‐turbo spin echo images compared to 0–19% in turbo spin echo images. Findings indicated that the WARP‐turbo spin echo sequence reduces the severity of susceptibility artifacts in canine stifle joints post TPLO. However, variable depiction of local anatomy warrants further refinement of the technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号