首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Haematological parameters [red blood cell count (RBC), white blood cell count (WBC), packed cell volume (PCV), haemoglobin concentration, mean cell volume (MCV), mean cell haemoglobin (MCH) and mean cell haemoglobin concentration (MCHC)] in resting Lipizzan horses were determined for 143 stallions, 104 mares and 25 foals. The mean RBC and WBC values in Lipizzans were in the lower part of the normal range for warm-blooded horses. The mean PCV, MCV and MCH values were higher, but the mean haemoglobin concentration and MCHC values were lower than reported for other warm-blooded horses. In foals, the mean RBC, WBC, PCV, haemoglobin concentration and MCHC values were higher, whereas MCV and MCH were lower than in older animals. Results indicating a significant decrease in WBC (P < 0.01) and an increase in MCV, MCH and MCHC (P < 0.05) with increasing age are consistent with some other reports on warm-blooded horses. The age-related variations in RBC and PCV were less marked. Contrary to some reports, RBC (P < 0.01), WBC and haemoglobin concentration (P < 0.001) were higher in Lipizzan stallions than in mares, but differences in MCHC, MCH and MCV were insignificant. The specific haematological values determined in Lipizzans are presumably a result of selection and should be taken into consideration when dealing with this race of horses.  相似文献   

2.
Blood samples were taken from 78 wild and 21 farmed sika deer (Cervus nippon yesoensis) using ketamine-xylazine sedation during their excited (82 deer) and resting (17 deer) states. Red cell count (RBC), hemoglobin (Hb), packed cell volume (PCV) and mean corpuscular volume (MCV) were significantly higher and mean corpuscular hemoglobin concentration (MCHC) was lower in excited deer than in resting deer. There was no significant difference in total leukocyte count (WBC) between excited and resting wild males, while a marked increase of WBC with neutrophilia was observed in excited wild females. RBC and PCV were significantly higher and MCH was lower in excited males than in excited females. In wild deer, WBC was significantly higher in females than in males, but there was no significant difference in WBC between farmed males and females. Sex differences in the hematological parameters were not observed in fawns (10 months).  相似文献   

3.
BACKGROUND: Standardized hematologic methods and reference intervals have not been established for cartilaginous fishes (sharks, skates, and rays) despite the large number of animals displayed in zoos and aquariums worldwide. OBJECTIVE: The focus of this study was to validate CBC methods for sandbar shark (Carcharhinus plumbeus) blood, based on criteria established in human medicine, for the following tests: RBC count, total WBC count, PCV, hemoglobin (Hgb) concentration, and WBC differential percentages. METHODS: Replicate CBCs were performed using blood samples from 5 captive sandbar sharks. Three protocols for RBC and total WBC counts were compared, as were different centrifugation times for PCV determination, and 2 methods for Hgb concentration. Means, minimum and maximum values, and CVs were compared to CAP and CLIA performance guidelines for human tests. RESULTS: Total WBC counts in a diluent modified for elasmobranch blood, Hgb concentration by the cyanmethemoglobin method after removal of nuclei, and WBC differential percentages showed acceptable performance. PCV results were acceptable when tubes were centrifuged for at least 5 minutes. Total RBC counts by all 3 methods exceeded the acceptable error for manual counts of human cells. CONCLUSIONS: Standardized CBC tests can be used as health assessment tools for elasmobranchs. Total RBC counts should be viewed as estimates.  相似文献   

4.
BACKGROUND: Blood samples collected from farm animals for hematology testing may not reach the laboratory or be examined immediately upon collection, and in some cases may need to be transported for hours before reaching a laboratory. OBJECTIVE: The objective of this study was to investigate the artifactual changes that may occur in PCV, hemoglobin (Hgb) concentration, and cell counts in bovine, caprine, and porcine blood samples stored at room (30 degrees C) or refrigerator (5 degrees C) temperature. METHODS: Baseline values for PCV, Hgb concentration, and RBC and WBC counts were determined immediately after blood collection from 36 cattle, 32 goats, and 48 pigs using manual techniques. Blood samples were split into 2 aliquots and stored at 30 degrees C or 5 degrees C. Hematologic analyses were carried out at specified intervals during 120 hours of storage. Results were analyzed by repeated measure ANOVA; results at different temperatures were compared by paired t-tests. RESULTS: Compared to baseline values, there were no significant changes in Hgb concentration, RBC count, or WBC count in samples from cattle; in Hgb concentration and RBC count in samples from goats; and in Hgb concentration and WBC count in samples from pigs throughout the 120 hours of storage at both 30 degrees C and 5 degrees C. Significant changes (P <.05) from baseline occurred in PCV after 14 hours of storage at 30 degrees C and after 19 hours of storage at 5 degrees C in cattle and goats; and after 10 hours of storage at 30 degrees C and 14 hours of storage at 5 degrees C in pigs. Significant changes also were observed in Hgb concentration at 96 hours at 30 degrees C and 5 degrees C, and in RBC counts at 48 hours at 30 degrees C and 96 hours at 5 degrees C in porcine samples; and in total WBC counts at 120 hours at 30 degrees C and 5 degrees C in caprine samples. Artifactual changes were more pronounced in the samples stored at 30 degrees C. CONCLUSIONS: At both 30 degrees C and 5 degrees C, blood samples from cattle and goats can be stored for up to 12 hours, while blood samples from pigs can be stored for up to 8 hours without any significant changes in PCV. Blood samples from all 3 species can be stored for more than 24 hours without significant changes in Hgb concentration, RBC count, and total WBC count.  相似文献   

5.

Background

Ethiopia, particularly in the Northwest region, is affected by both tsetse and non-tsetse fly transmitted trypanosomosis, with significant impact on livestock productivity. The aim of this study was to determine and compare clinical findings and haematological values between experimental infections induced by Trypanosoma vivax isolates from areas of either transmission mode. Sixteen young (aged between 6 and 12 months) Zebu cattle (Bos indicus), purchased from a trypanosome-free area and confirmed to be trypanosome-negative, were randomly assigned into four groups of four animals. Groups 1, 2 and 3 were infected with an isolate from a tsetse infested or one of two isolates from a non-tsetse infested area, and group 4 was a non-infected control. All animals in the infected groups were inoculated intravenously with 2 × 106 trypanosomes from donor animals. The experimental animals were monitored for eight consecutive weeks post infection for clinical signs, parasitaemia and haematological changes in packed cell volume (PCV), haemoglobin concentration (Hgb), total red blood cell (RBC) and white blood cell (WBC) counts, differential WBC count and blood indices (mean corpuscular volume [MCV], mean corpuscular haemoglobin and mean corpuscular haemoglobin concentration).

Results

Infection was characterized by reduced feed intake, weakness, pyrexia, parasitaemia, rough hair coat, enlarged prescapular lymph nodes, lacrimation, weight loss, pallor mucus membrane and dehydration. Body weight loss in all infected groups was significantly higher than in the non-infected control. Similarly, body weight loss was higher (P < 0.001) in animals infected with the tsetse infested isolate than with the non-tsetse infested isolates. The mean PCV, Hgb, total RBC and WBC counts were lower (P < 0.001), and mean MCV was higher (P = 0.01) in all infected groups than in non-infected control animals at different time points during the study period. Except for minor variations in haematological values, the overall changes were similar in all infected groups.

Conclusion

Clinical signs and significant reduction in haematological values in the infected groups indicated the pathogenicity of the T. vivax parasites. Pathogenicity of T. vivax from the non-tsetse infested area can be considered as nearly as important as that of its counterpart derived from the tsetse infested area.  相似文献   

6.
Clostridium chauvoei CH3 and Kad1 strains were found to cause marked changes in the blood parameters during the course of blackleg disease. These changes displayed by CH3 were found to be more marked than the local Kad1 strain. Results of changes in the haematological values in calves infected with blackleg organisms, showed an increase in RBC, PCV, Hb and the total leukocyte count. MCHC and MCH remained within normal range values, however, a terminal significant increase of MCV was obtained. Thrombocytes showed a steady drop after infection to the time of death of the animals.  相似文献   

7.
BACKGROUND: The shortnose sturgeon, Acipenser brevirostrum, is an imperiled species distributed along the Atlantic coast of North America. Interest in replenishing wild stocks with hatchery-reared fish has created a need for accurate hematologic and biochemical reference intervals to evaluate the health of both fish raised in aquaculture systems and fish in the wild. OBJECTIVES: The objective of this study was to generate hematologic and biochemistry reference intervals for healthy shortnose sturgeon. METHODS: Blood samples were collected in heparinized tubes from 77 shortnose sturgeon raised in flow-through aquaculture systems. Whole blood and plasma samples were analyzed for hematologic and biochemical variables using standard techniques. Reference intervals were calculated as the central 95% (percentile) of data. RESULTS: Hematologic reference intervals (n = 46) were as follows: PCV 26-46%, hemoglobin 5.7-8.7 g/dL, MCV 307-520 fL, MCH 65.9-107.1 pg, MCHC 15-30 g/dL, plasma proteins (refractometry) 2.8-6.0 g/dL, RBC count 0.65-1.09 x 10(6)/microL, total WBC count 28,376-90,789/microL, small lymphocytes 9063-56,656/microL, large lymphocytes 2122-10,435/microL, neutrophils 3758-33,592/microL, monocytes 0-7137/microL, eosinophils 0-1544/microL, thrombocyte-like cells 6863-23,046/microL, thrombocytes 32,205-122,179/microL, and neutrophil:lymphocyte ratio 0.068-1.026. Plasma chemistry reference intervals (n = 77) were as follows: total protein 2.7-5.3 g/dL, albumin 0.8-1.7 g/dL, globulins 1.8-3.7 mg/dL, creatinine 0-1.4 mg/dL, total bilirubin 0-0.1 mg/dL, alkaline phosphatase 47-497 U/L, aspartate aminotransferase 90-311 U/L, sodium 124-141 mmol/L, potassium 2.9-3.7 mmol/L, chloride 106-121 mmol/L, calcium 6.6-12.1 mg/dL, magnesium 1.6-2.3 mg/dL, phosphorus 5.1-8.1 mg/dL, glucose 37-74 mg/dL, cholesterol 42-133 mg/dL, and osmolality 232-289 mOsm/kg. CONCLUSION: Reference values reported here will be useful for the early detection, identification, and monitoring of disease and sublethal conditions in cultured shortnose sturgeon.  相似文献   

8.
试验对海拔 3 0 0 0m的藏南谷地林芝引入家兔进行了部分生理指标的对比分析。测定了呼吸频率、心率、生理体温、血清蛋白质含量和血红蛋白含量。统计分析表明 :所测定项目的结果在 3品种兔之间均无明显差异 (P >0 0 5) ;但血红蛋白电泳分析 :3品种兔均呈现出A、A2 ,A33个区带 ,发现A3带以青紫兰兔最低 ,与其他 2品种兔差异极显著 (P <0 0 1 ) ;加里福尼亚兔A3带最高 ,显著高于中国白兔 (P <0 0 5)及青紫兰兔 (P <0 0 1 )。血清蛋白质电泳分析表明 :高原家兔的血清白蛋白均明显高于文献报道的低海拔饲养的新西兰白兔 ,血清总蛋白及其球蛋白含量明显下降  相似文献   

9.
The blood values of the German Brown, N'Dama and their three-quarter, half and quarter hybrids were studied to ascertain if and how some haematological parameters changed with crossbreeding. It was found that the red blood cell (RBC) and white blood cell (WBC) count and packed cell volume percentage (PCV) were significantly higher (P less than 0.01) in the N'Dama than in the German Brown; the crosses had values which were intermediate as compared to the two parent breeds. Generally, the changes in the mean blood values paralleled changes in the expected genotypes resulting from crossbreeding of the two parent breeds. The tendency of the blood values to change in direct proportion to the degree of N'Dama contribution was strongest for the WBC, followed by the PCV and RBC, respectively. A small random sample for leucocyte differential count did not reveal any differences amongst the genotypic groups.  相似文献   

10.
Blood samples form 120 consecutive clinical cases (40 cats, 40 dogs and 40 horses) were analyzed on the QBC VetAutoread analyzer and the results compared with those obtained by a Baker 9000 electronic resistance cell counter and a 100-cell manual differential leukocyte (WBC) count. Packed cell volume (PCV), hemoglobin (Hb) concentration, mean cell hemoglobin concentration (MCHC), and platelet, total WBC, granulocytes, and lymphocyte plus monocyte (L+M) counts were determined. Indistinct separation of red blood cell and granulocytes layers on the QBC VetAutoread was observed in samples from five cats (12.5%), two dogs (5%), and one horse. Significantly different (P=0.002) median values for the two methods were obtained for PCV, Hb concentration, MCHC and platelet count in cats; PCV, MCHC, WBC, count and granulocytes count in dogs; and PCV, Hb concentration, MCHC and WBC, granulocytes and platelet counts in horses. Results from the QBC VetAutoread should not be interpreted using reference ranges established using other equipment. Results were abnormal on a limited number of samples; however, when correlation coefficients were low, marked discrepancy existed between values within as well as outside of reference ranges. Spearman rank correlation coefficients were excellent (r=0.93) for PCV and Hb concentration in dogs, and Hb concentration and WBC count in horses. Correlation was good (r=0.80-0.92) for PCV and Hb concentration in cats, WBC count in dogs, and PCV, granulocytes count and platelet count in horses. For remaining parameters, correlation was fair to poor (r=0.79). Acceptable correlations (r>0.80) were achieved between the two test systems for all equine values except MCHC and L+M count, but only for PCV and HB concentration in feline and canine blood samples.  相似文献   

11.
Background: A CBC is an integral part of the assessment of health and disease in companion animals. While in the past newer technologies for CBC analysis were limited to large clinical pathology laboratories, several smaller and affordable automated hematology analyzers have been developed for in‐clinic use. Objectives: The purpose of this study was to compare CBC results generated by 7 in‐clinic laser‐ and impedance‐based hematology instruments and 2 commercial laboratory analyzers. Methods: Over a 3‐month period, fresh EDTA‐anticoagulated blood samples from healthy and diseased dogs (n=260) and cats (n=110) were analyzed on the LaserCyte, ForCyte, MS45, Heska CBC, Scil Vet ABC, VetScan HMT, QBC Vet Autoread, CELL‐DYN 3500, and ADVIA 120 analyzers. Results were compared by regression correlation (linear, Deming, Passing‐Bablok) and Bland–Altman bias plots using the ADVIA as the criterion standard for all analytes except HCT, which was compared with manual PCV. Precision, linearity, and carryover also were evaluated. Results: For most analytes, the in‐clinic analyzers and the CELL‐DYN performed similarly and correlated well with the ADVIA. The biases ranged from ?0.6 to 2.4 × 109/L for WBC count, 0 to 0.9 × 1012/L for RBC count, ?1.5 to 0.7 g/dL for hemoglobin concentration, ?4.3 to 8.3 fL for MCV, and ?69.3 to 77.2 × 109/L for platelet count. Compared with PCV, the HCT on most analyzers had a bias from 0.1% to 7.2%. Canine reticulocyte counts on the LaserCyte and ForCyte correlated but had a negative bias compared with those on the ADVIA. Precision, linearity, and carryover results were excellent for most analyzers. Conclusions: Total WBC and RBC counts were acceptable on all in‐clinic hematology instruments studied, with limitations for some RBC parameters and platelet counts. Together with evaluation of a blood film, these in‐clinic instruments can provide useful information on canine and feline patients in veterinary practices.  相似文献   

12.
BACKGROUND: Hematologic data are used routinely in the health care of humans and domestic mammals. Similar data for fish are largely fragmentary or have not been collected. OBJECTIVES: The primary purpose of this study was to determine hematologic reference intervals for koi, an ornamental strain of the common carp (Cyprinus carpio). Secondarily, the morphology, cytochemical reactions, and ultrastructure of koi blood cells were characterized. METHODS: A CBC was performed manually on heparin-anticoagulated blood specimens using Natt and Herrick's diluent and a Neubauer-ruled hemacytometer. Leukocyte differential counts were done on Wright-Leishman- and Diff-Quik-stained blood smears. Cytochemical reactions of koi leukocytes were determined using commercial kits. Transmission electron microscopy was performed to characterize the ultrastructural features of koi blood cells. RESULTS: Hematologic reference intervals were established for healthy koi for PCV (30-34%), hemoglobin concentration (6.3-7.6 g/dL), RBC count (1.7-1.9 X 10(6)/ microL), WBC count (19.8-28.1 X 10(3)/ microL), RBC indices, and differential leukocyte counts. Lymphocytes were the predominant leukocyte (accounting for up to 80% of all leukocytes), whereas eosinophils were rare. Basophils were positive with PAS staining. Naphthol AS-D chloroacetate esterase activity was observed only in eosinophils. alpha-Naphthyl butyrate esterase and beta-glucuronidase activities were positive in monocytes. Some lymphocytes were reactive for alpha-naphthyl butyrate esterase and acid phosphatase activity. Ultrastructurally, leukocytes, erythrocytes, and thrombocytes were identified on the basis of cytoplasmic organelles and granule appearance. CONCLUSION: Hematologic reference intervals and knowledge of the cytochemical reactions and ultrastructural characteristics of koi leukocytes will help standardize hematologic studies in this species.  相似文献   

13.
果寡糖对固始鸡血液生理指标的影响   总被引:3,自引:0,他引:3  
本试验旨在研究不同添加剂量的果寡糖对固始鸡血液生理指标的影响,并确定果寡糖的最佳添加剂量。选用1日龄固始鸡公雏150只,随机分成5个处理组,1个为对照组,其余4个为试验组,对照组不加果寡糖,其他4个组的果寡糖添加水平分别为3、5、7mg/kg和9mg/kg。测定红细胞压积(PCV)、血红蛋白(Hb)含量、红细胞数量、白细胞数量、平均红细胞体积(MCV)、平均红细胞血红蛋白含量(MCH)和平均红细胞血红蛋白浓度(MCHC)等指标。试验结果表明:1)21和42日龄时,果寡糖试验组的红细胞压积、血红蛋白含量、红细胞数量和白细胞数量均显著高于对照组(P<0.05);与对照组相比,试验组的MCH和MCHC均略有升高,并且可以显著提高MCHC(P<0.05);2)日粮中添加5mg/kg果寡糖对提高红细胞压积、血红蛋白含量、红细胞数量、白细胞数量、MCH和MCHC具有最佳效果。  相似文献   

14.
BACKGROUND: Most hematologic analyses are performed within a short time of blood sampling, but samples collected at the end of a week may have to be stored for up to 2 days. The stability of hematologic constituents is poorly documented. OBJECTIVE: The objective of this study was to compare the results of RBC, WBC and platelet counts, hemoglobin (Hgb) concentration, and MCV before and after storage of canine blood at room temperature for 24 and 48 hours. METHODS: One hundred fifty-two K3-EDTA canine blood specimens from 2 veterinary hospitals were analyzed within 4 hours of collection, then 24 and 48 hours later with a Coulter T540 hematology analyzer. Results were compared by Passing-Bablock agreement, difference plots, and according to their classification as normal or abnormal based on reference intervals. RESULTS: RBC count and Hgb concentration were stable for the duration of the study. Differences in WBC and platelet counts varied with the specimen, independently of the initial value. MCV increased consistently over the 2 days. However, only a few results were misclassified. CONCLUSION: Whole blood specimens stored for up to 2 days at room temperature are suitable for cell counts and Hgb measurement. However, potential variations have to be known to avoid misinterpretations, especially near the decision limits.  相似文献   

15.
BACKGROUND: Hereditary canine stomatocytosis has been described in purebred Alaskan Malamutes, Drentse Patrijshonds, and Miniature Schnauzers. In humans, hereditary stomatocytosis is a heterogeneous group of congenital disorders characterized by the presence of stomatocytes in blood, increased osmotic fragility, and frequently, hemolytic anemia. OBJECTIVE: Our objective was to describe hematologic findings and RBC characteristics in 7 closely related Standard Schnauzers with stomatocytosis. METHODS: The following parameters were measured using an automated analyzer: HCT, RBC, hemoglobin (Hb) concentration, MCV, MCH, MCHC, red cell distribution width (RDW), WBC, platelet count, mean platelet volume (MPV), thrombocrit (PCT), and platelet distribution width (PDW). Differential leukocyte count, platelet estimate, reticulocyte count, and the percentage of stomatocytes in blood films were microscopically evaluated. An osmotic fragility test of RBCs and measurement of intracellular Na+, K+, and 2,3-diphosphoglycerate (2,3-DPG) concentrations were also performed. RESULTS: The affected dogs had macrocytosis (80.0 +/- 4.2 fL, reference interval 60-76 fL), decreased MCHC (29.3 +/- 0.8 g/dL, reference interval 32-39 g/dL), slightly increased RDW (17.3 +/- 0.4%, reference interval 12-16%), and an increased reticulocyte count (1.55 +/- 0.77%, reference interval <1%). The percentage of stomatocytes in blood films varied from 0.6 to 18.9% of all RBCs. Erythrocyte osmotic fragility and intracellular Na+ (138.1 +/- 3.2 mmol/L; controls 99 +/- 6.1 mmol/L), K+ (8.1 +/- 0.8 mmol/L; controls 6.1 +/- 0.5 mmol/L), and 2,3-DPG (21.9 +/- 2.0 micromol/g Hb; controls: 14.6 +/- 3.3 micromol/g Hb) concentrations were increased in dogs with stomatocytosis. CONCLUSIONS: Hematologic findings and the metabolic defects in RBCs in these Standard Schnauzers were consistent with a diagnosis of stomatocytosis. Parentage analysis suggests that stomatocytosis in Standard Schnauzers may have a hereditary component.  相似文献   

16.
The effects of dexamethasone at different dose regimens on some haematological parameters and serum biochemistry were studied in the camel. Dexamethasone increased the serum concentration of glucose as well as neutrophils and total leukocyte count in the blood. Conversely, the serum concentrations of potassium and phosphorus and lymphocyte count in blood were decreased by dexamethasone treatment. Dexamethasone, however, had no effect on the activities of CPK and gamma-GT, on the serum concentrations of creatinine, BUN, total bilirubin, cholesterol and Na and on PCV, Hb, ESR, MCV and MCHC values.  相似文献   

17.
A Baker 9000 hematology analyzer (electronic impedance) was purchased to replace an Ortho ELT-8/ds analyzer (laser optics) due to discontinued technical support. An analytical comparison of hemograms from healthy dogs, rats, and mice was made from paired disodium ethylenediamine tetra-acetate anticoagulated blood samples. Both instruments were calibrated with human blood products, and the ELT-8/ds hematocrit (HCT) was calibrated to a spun packed cell volume (PCV) for each species. For Beagle dogs (n = 49), Baker 9000 mean platelet (PCV) counts had a negative bias of -89 X 10(3)/microliter when compared to ELT-8/ds values. Mean +/- standard error manual PLT counts compared well with Baker 9OOO values for dogs (n = 10): 369 +/- 28 vs. 367 +/- 27 X 10(3)/microliter; r = 0.93. For CD-1 mice (n = 44), Baker 9000 mean white blood cell (WBC) counts had positive biases of 1. 1 X 10(3)/microliter when compared to ELT-8/ds and 0.5 X 10(3)/microliter when compared to hemacytometer counts. Diluted microsamples using the predilution mode on the Baker 9000 compared well with undiluted samples for mice. For Sprague-Dawley rats (n = 70), Baker 9000 mean WBC, red blood cell (RBC), and PLT counts had absolute biases of 0.8 X 10(3)/microliter, -1.09 X 10(6)/microliter, and -357 X 10(3)/microliter, respectively, when compared to ELT-8/ds values. Baker 9000 RBC, WBC, and PLT counts from rats compared well with reference hemacytometer counts. The Baker 9000 HCT determination for rats had an absolute negative bias of 6% when compared to the ELT-8/ds values or spun PCV. The Baker 9000 required whole blood calibration to PCV for accurate determination of HCT for rats. The biases between analyzers may be due to inherent physical differences between the analytical methods and/or the calibration techniques.  相似文献   

18.
Turtle populations are decreasing dramatically due to habitat loss and collection for the food and pet market. This study sought to determine hematologic values in two species of turtles to help assess health status of captive and wild populations. Blood samples were collected from 12 individuals of the Pascagoula map turtle (Graptemys gibbonsi) and seven individuals of the southeast Asian box turtle (Cuora amboinensis) from the Savannah River Ecology Laboratory (South Carolina, USA). The hematologic data included hematocrit, total solids, erythrocyte count, leukocyte count, and differential and percentage leukocyte counts. Low hematocrit values and high basophil counts were found in both species. The basophil was the most abundant leukocyte in the Pascagoula map turtle (median = 0.80 x 10(9)/L), whereas in the Southeast Asian box turtle the most abundant leukocyte was the heterophil (median = 2.06 x 10(9)/L).  相似文献   

19.
The purpose of the present study was to calculate the critical difference between 2 analytical results for the red blood cell count (RBC), the white blood cell count (WBC), the haemoglobin concentration (Hb), and the haematocrit (PCV) in blood from Red Danish Dairy cows. The critical difference can help to judge whether the difference between 2 consecutive analytical results from the same animal may be safely ascribed to natural variation or not. To calculate the critical differences, blood samples from 20 clinically healthy lactating cows were collected once daily for 5 consecutive days. The total variance of the analytical results was divided into the component of variance between cows (S2Inter), the component of variance for days within cows (S2Intra), and the component of variance for measurements (S2Anal) using nested analysis of variance. The critical difference was then calculated from S2Intra and S2Anal as 0.61 x 10(12)/l for RBC, 2.2 x 10(9)/l for WBC, 0.79 mmol/l for Hb, and 0.07 for PCV. The critical differences may be used as guidelines to indicate potentially important changes in the parameters. However, the analytical results should not be assessed by the critical differences alone, but should also be compared to the corresponding reference intervals.  相似文献   

20.
日粮添加免疫生长促进剂C96对雏鸡若干血液指标的影响   总被引:1,自引:0,他引:1  
选择120只1日龄AA商品健康雏鸡,随机分为4组,每组30只。初步观察了日粮添加免疫生长促进剂C96对血液中红细胞总数(RBC)、比容(PCV)、血红蛋白含量(Hb)、网织红细胞比例(RCC)、白细胞总数(WBC)等的影响。结果表明:肉雏鸡在15d时,日粮添加C96为11mg/kg,饲料的C96组和疫苗-C96组,与对照组和疫苗组比较,RBC和Hb增高,WBC显著下降,RCC降低,PCV无明显规律性变化;30d和45d时,添加C96组和疫苗-C96组的RBC、Hb和PCV,与对照组和疫苗组基本相近,WBC和RCC均比对照组和疫苗组低或明显低。但30d时疫苗组的WBC比对照组高。整个试验期,RBC、WBC和PCV随日龄的增长呈上升趋势,RCC呈波动性下降。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号