首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 848 毫秒
1.
OBJECTIVE: To describe the anatomic features of the pituitary gland region in horses via computed tomography (CT) and determine the accuracy of CT for estimating normal equine pituitary gland dimensions. ANIMALS: 25 adult horses with no clinical signs of pituitary disease. PROCEDURE: Transverse CT images and gross transverse tissue sections were compared in 2 horses. Contrast-enhanced CT of the pituitary gland region was performed postmortem in 23 horses with 4 slice thickness and interval settings (10-mm contiguous or overlapping slices and 4-mm contiguous or overlapping slices). Gross and CT estimates of pituitary gland dimensions were compared via ANOVA. Accuracy of CT estimates was calculated with gross pituitary gland measurements as the known value. RESULTS: Pituitary glands were located between the temporomandibular joints and had contrast enhancement. Mean gross dimensions were length, 2.11 cm; width, 2.16 cm; height, 0.98 cm; and volume, 2.66 cm3. Gross measurements and CT estimates of pituitary gland length from 10-mm contiguous and overlapping slices did not differ. Gross measurements and CT estimates of pituitary gland width from 4-mm contiguous and overlapping slices did not differ. Estimates of height and volume from all CT techniques differed from gross measurements. Accuracies for CT estimates were length, 88 to 99%; width, 81 to 92%; height, 58 to 71%; and volume, 43 to 55%. CONCLUSIONS AND CLINICAL RELEVANCE: Accuracy of estimates of pituitary gland dimension in horses varied with CT scanning technique; via CT estimates of length and width of glands were more accurate than estimates of height or volume.  相似文献   

2.
Dynamic computed tomography (CT) of the pituitary gland was performed on four healthy male dogs of similar size, weight and age. The pituitary gland region was first identified on lateral scout and transverse non-contrast images. After localization, water soluble iodinated contrast medium was administered intravenously as a bolus at a dose of 1 ml/lb using a pressure injector at an injection rate of 10 ml/sec and a total of 40 post contrast images of the pitutary gland were acquired. No images were made after 400 seconds. The same pituitary region was imaged in each slice. The slice thickness was 1.5 mm, with a two second scan time and an eight second delay between images (resulting in images every ten seconds). The contrast medium injection and initial image were acquired simultaneously, resulting in a non-contrast enhanced initial image. At the completion of the CT scan, a region of interest (ROI) was drawn around the pituitary gland and time density data were obtained. The mean pituitary Hounsfield number was plotted as a function of time. A bi-exponential least squares model was used to derive the best fitting line through the data. The mean relative peak increase in pituitary Hounsfield Units (HU) was 65.9% +/- 2.1%. After the initial increase there was a decrease in pituitary Hounsfield number with a half-time of 16.1 seconds, followed by a slower phase with a half-time of 16.5 minutes. The mean pituitary gland HU value during the period of gradual opacity decline was 35.0% +/- 4.4% above that of the pre-contrast image. Establishing the enhancement pattern in the canine pituitary gland is the precursor to the clinical application of dynamic CT of the pituitary gland to diagnose pituitary microadenomas and/or small macroadenomas before they become exceptionally large.  相似文献   

3.
Magnetic resonance imaging was conducted on previously frozen left carpi from six normal dogs using a 1.5 Tesla magnet in combination with a transmit/receive wrist coil. Three-millimeter thick T1-weighted spin-echo images and 1-mm thick T2*-weighted gradient-recalled 3-D images were obtained in dorsal and sagittal planes. Carpi were embedded, sectioned, and stained. Anatomic structures on the histologic sections were correlated with the MR images. All of the carpal ligaments plus the radioulnar articular disc and the palmar fibrocartilage were identified on MR images. The accessorio-quartile ligament, which had not been well described previously in dogs, was also identified. It originated on the accessory carpal bone and inserted on the fourth carpal bone. The T2*-weighted gradient echo imaging technique provided better images than T1-weighted technique, largely because thinner slices were possible (1 mm vs. 3 mm), resulting in less volume averaging of thin ligaments with surrounding structures. Although MRI is currently the imaging modality of choice to identify ligamentous injury in humans, further studies are needed to determine if abnormalities can be detected in canine carpal ligaments using MRI.  相似文献   

4.
The aim of the study was to assess the effects of changing acquisition parameters used for high-resolution in vivo magnetic resonance (MR) microscopy on image quality and scan time. The head or abdomen of 11 normal and 1 glioblastoma-bearing anesthetized BALB/c mice were imaged using a high-resolution 7.0-Tesla magnet. Scan parameters such as matrix size (MTX), slice thickness (ST), number of excitations (NEX), pulse sequence type including repetition time (TR) and echo time (TE), respiratory gating, and intraperitoneal contrast medium administration were altered to assess their actual effect on signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) as compared to calculated effects. As expected, SNR increased with increasing ST or NEX and with decreasing MTX. However, although the empirical increase in SNR was similar to that expected for increased ST, it was less than that anticipated for increasing NEX or decreasing MTX. Increasing NEX and applying respiratory gating both increased SNR and reduced the image degradation associated with respiratory motion in images of the abdomen. Intraperitoneal contrast medium administration produced a marked increase in CNR in the subject with the implanted glioblastoma, suggesting that this route is satisfactory for the enhancement of lesions disrupting the blood-brain barrier. The consequence of improving image quality in terms of spatial and contrast resolution is increased scan time. However, the actual increase in SNR when altering acquisition parameters may not be as much as predicted by theory.  相似文献   

5.
The aim of this study was to adapt the human magnetic resonance imaging (MRI) sequences for use in the routine examination of canine mammary glands. MRI was performed on 10, middle- to old-aged dogs of different breeds. It was found that T1- and T2-weighted spin echo, short T1 inversion recovery sequences and a gradient echo (GE) dynamic T1-weighted measurement made in the coronal and transversal planes were the most informative MR diagnostic methods for imaging canine mammary tumours. The static MR technique is the most detailed imaging modality for differentiating the tissue types in the substance of the mammary gland. The MRI findings were in close relationship with the histological result (five malignant mixed tumours and five cases of invasive ductal carcinoma). Using the GE dynamic contrast-enhanced sequence the morphological patterns as well as the kinetic parameters proved to be malignant. By the dynamic measurement technique initial information was obtained on the contrast enhancing properties, which are valuable factors during in vivo staging and in the prognostic work.  相似文献   

6.

Background

Rabbits are widely accepted as an animal model in neuroscience research. They also represent very popular pet animals, and, in selected clinical cases with neurological signs, magnetic resonance imaging (MRI) may be indicated for imaging the rabbit brain. Literature on the normal MRI anatomy of the rabbit brain and associated structures as well as related reference values is sparse. Therefore, it was the purpose of this study to generate an MRI atlas of the normal rabbit brain including the pituitary gland, the cranial nerves and major vessels by the use of a 3 T magnet.

Results

Based on transverse, dorsal and sagittal T2-weighted (T2w) and pre- and post-contrast 3D T1-weighted (T1w) sequences, 60 intracranial structures were identified and labeled. Typical features of a lissencephalic brain type were described. In the 5 investigated rabbits, on T1w images a crescent-shaped hyperintense area caudodorsally in the pituitary gland most likely corresponded to a part of the neurohypophysis. The optic, trigeminal, and in part, the facial, vestibulocochlear and trochlear nerves were identified. Mild contrast enhancement of the trigeminal nerve was present in all rabbits. Absolute and relative size of the pituitary gland, midline area of the cranial and caudal cranial fossa and height of the tel- and diencephalon, 3rd and 4th ventricles were also determined.

Conclusions

These data established normal MRI appearance and measurements of the rabbit brain. Results provide reference for research studies in rabbits and, in rare instances, clinical cases in veterinary medicine.

Electronic supplementary material

The online version of this article (doi:10.1186/s13028-015-0139-6) contains supplementary material, which is available to authorized users.  相似文献   

7.
Hege  Kippenes  DVM  Patrick R.  Gavin  DVM  PhD  Susan L.  Kraft  DVM  PhD  Ronald D.  Sande  DVM  MS  PhD  Russell L.  Tucker  DVM 《Veterinary radiology & ultrasound》2001,42(2):130-133
The pituitary gland was measured from transverse magnetic resonance T1-weighted images after Gadolinium administration in 96 dogs weighing from 13 to 45 kg. The measurements were done by hand with calipers. The mean (+/- standard deviation) pituitary gland height was 5.1 mm (+/-0.9 mm). The mean width was 6.4 mm (+/- 1.1 mm). The correlation coefficient between pituitary and brain measurements, between pituitary measurement and body weight, and brain measurements and body weight was 0.0 to 0.3. A hyperintense region was present on T1-weighted images in the center of the pituitary gland in 64% of the dogs. At necropsy the pituitary glands were grossly and histologically normal. No pituitary gland measurements were performed at necropsy.  相似文献   

8.
The magnetic resonance imaging appearance of the feline middle ear is described in three healthy cats and in five cats with middle ear disease. Owing to the good spatial resolution, multiplanar slice orientation as well as display high contrast resolution of soft tissue, in particular fluids, MR imaging was helpful prior to surgery. It is superior to radiography which failed to allow identification of the abnormality in two of our five cats. MR imaging for middle ear disease should include dorsal and transverse plane images using T1- and T2-weighted sequences. In the presence of a mass within the bulla or the external ear canal application of contrast medium is helpful.  相似文献   

9.
Preoperative knowledge of the renal vascular anatomy is important for selection of the appropriate feline renal donor. Intravenous urograms (IVUs) have been performed routinely to screen potential donors at the Veterinary Hospital of the University of Pennsylvania (VHUP), but the vascular phase views lack sufficient detail of the renal vascular anatomy. Computed tomography angiography (CTA), which requires a helical computed tomography (CT) scanner, has been found to provide superior renal vascular anatomic information of prospective human renal donors. The specific aims of this study were as follows: 1) develop the CTA technique for the feline patient; and 2) obtain preliminary information on feline renal vessel anatomy in potential renal donors. Ten healthy, potential feline renal donors were anesthetized and imaged using a third-generation helical CT scanner. The time delay between i.v. contrast medium injection and image acquisition, and other parameters of slice collimation, slice interval, pitch, exposure settings, and reconstruction algorithms were varied to maximize contrast medium opacification of the renal vascular anatomy. Optimal CTA acquisition parameters were determined to be: 1) 10-sec delay post-i.v. bolus of iodinated contrast medium; 2) two serially acquired (corresponding to arterial and venous phases) helical scans through the renal vasculature; 3) pitch of 2 (4 mm/sec patient translation, 2 mm slice collimation); and 4) 120-kVp, 160-mA, and 1-sec exposure settings. Retrospective reconstructed CTA transverse images obtained at a 2-mm slice width and a 1-mm slice interval in combination with two-dimensional reformatted images and three-dimensional reconstructed images were qualitatively evaluated for vascular anatomy; vascular anatomy was confirmed at surgery. Four cats had single renal arteries and veins bilaterally; four cats had double renal veins. One cat had a small accessory artery supplying the caudal pole of the left kidney. One cat had a left renal artery originating from the aorta at a 90 degrees angle with the cranial mesenteric artery. CTA of the feline renal vascular anatomy is feasible, and reconstruction techniques provide excellent anatomic vascular detail. CTA is now used routinely at VHUP to screen all potential feline renal donors.  相似文献   

10.
OBJECTIVE: To correlate anatomic features of the equine tarsus identified in plastinated sections with images obtained via magnetic resonance imaging (MRI). ANIMALS: 4 horses. PROCEDURE: MRI (1.5-Tesla magnet) of the tarsus was performed on the pelvic limbs of 4 clinically normal horses following euthanasia. After imaging, tarsocrural joint spaces and vasculature were injected with colored latex. Sagittal and transverse sections of the tarsi were plastinated to facilitate interpretation of MR images. RESULTS: Relevant anatomic structures were identified and labeled on the plastinated tissue slices and corresponding MR images. Results indicated high correlations between MRI findings and those of plastinated sections. CONCLUSIONS AND CLINICAL RELEVANCE: The data obtained provided certain reference standards for normal anatomic structure sizes and positions in the equine tarsus. This information may aid future physiologic or clinical studies of this joint.  相似文献   

11.
Medical records and magnetic resonance (MR) images of 14 cats with inflammatory diseases affecting the central nervous system (CNS) were reviewed retrospectively. Cases included eight cats with feline infectious peritonitis and two cats with toxoplasmosis. Abnormalities affecting the CNS were observed in MR images in 10 (71%) cats. Intracranial lesions appeared as slightly hypointense foci in T1-weighted images in two (14%) cats, as hyperintense foci in T2-weighted images in seven (50%) cats and as hyperintense foci after intravenous administration of a gadolinium-based contrast medium in 10 (71%) cats. In six cats with lesions in T1- and/or T2-weighted images, additional lesions were visible in T1-weighted images obtained after gadolinium-based contrast medium administration. In three cats, lesions were visible only after contrast medium administration. In our study, MR imaging (MRI) did not appear to detect all cases of CNS inflammation in the population of cats with inflammatory cerebrospinal fluid (CSF); however, MRI adds information about the sites and morphology of intracranial lesions that should help to distinguish between neoplasia and inflammatory conditions and, possibly, between different inflammatory conditions.  相似文献   

12.
Magnetic resonance imaging (MRI) examinations from 18 dogs with a histologically confirmed peripheral nerve sheath tumor (PNST) of the brachial plexus were assessed retrospectively. Almost half (8/18) had a diffuse thickening of the brachial plexus nerve(s), six of which extended into the vertebral canal. The other 10/18 dogs had a nodule or mass in the axilla (1.2-338 cm3). Seven of those 10 masses also had diffuse nerve sheath thickening, three of which extended into the vertebral canal. The majority of tumors were hyperintense to muscle on T2-weighted images and isointense on T1-weighted images. Eight of 18 PNSTs had only minimal to mild contrast enhancement and many (13/18) enhanced heterogeneously following gadolinium DTPA administration. Transverse plane images with a large enough field of view (FOV) to include both axillae and the vertebral canal were essential, allowing in-slice comparison to detect lesions by asymmetry of structures. Higher resolution, smaller FOV, multiplanar examination of the cervicothoracic spine was important for appreciating nerve root and foraminal involvement. Short tau inversion recovery, T2-weighted, pre and postcontrast T1-weighted pulse sequences were all useful. Contrast enhancement was critical to detecting subtle diffuse nerve sheath involvement or small isointense nodules, and for accurately identifying the full extent of disease. Some canine brachial plexus tumors can be challenging to detect, requiring a rigorous multiplanar multi-pulse sequence MRI examination.  相似文献   

13.
Minimizing the volume of contrast administered for contrast‐enhanced computed tomography (CT) of the equine head is desirable for reducing costs and risks of adverse reactions, however evidence‐based studies on the effects of varying volumes on image quality are currently lacking. The objective of the current study was to determine whether low‐volume intraarterial administration of contrast medium would result in an equivalent image quality and tissue attenuation vs. high‐volume intravenous bolus administration. A prospective cross‐over experimental design was used in a sample of six horses. After anesthetic induction, the right carotid artery was exposed surgically and catheterized. Four CT scans of the cranium were performed for each horse: baseline, immediately following intraarterial contrast injection, five‐min postinjection (return to baseline) and a final scan after intravenous contrast administration. Soft tissue attenuation in predetermined regions of interest (ROI); and length, width, and height measurements of the pituitary gland were recorded at each time point. Horses were euthanized and measurements of the pituitary gland were repeated postmortem. No adverse reactions to contrast administration were observed. Intraarterial and intravenous administration of contrast medium resulted in significantly greater soft tissue enhancement of some brain ROI's and the pituitary gland vs. baseline values. Pituitary gland measurements made on postcontrast CT images did not differ from those obtained during postmortem examination. Findings indicated that low‐dose intraarterial administration of contrast material in the equine head resulted in comparable soft tissue enhancement vs. high volume intravenous administration.  相似文献   

14.
OBJECTIVE: To evaluate the effects of mitotane administration on the function and morphology of pituitary corticotrophs in clinically normal dogs. ANIMALS: 12 clinically normal adult Beagles. PROCEDURES: Dogs were randomly assigned to the control group or the mitotane treatment group. In mitotane treatment group dogs, mitotane was administered for 1 month. In both groups, ACTH stimulation testing and corticotrophin-releasing hormone (CRH) stimulation testing were performed. Magnetic resonance imaging (MRI) of the pituitary gland and brain was performed in mitotane treatment group dogs before and after administration of mitotane. After CRH stimulation testing and MRI, dogs were euthanatized and the pituitary gland and adrenal glands were excised for gross and histologic examination. RESULTS: ACTH concentrations in mitotane treatment group dogs were significantly higher than in the control group dogs following CRH stimulation. Magnetic resonance imaging revealed that pituitary glands were significantly larger in treatment group dogs after administration of mitotane, compared with before administration. On gross and histologic examinations, the adrenal cortex was markedly atrophied. Immunohistochemistry revealed hypertrophy of corticotrophs in pituitary glands of mitotane treatment group dogs. CONCLUSIONS AND CLINICAL RELEVANCE: These findings indicate that inhibition of the adrenal cortex by continuous administration of mitotane leads to functional amplification and morphologic enhancement of corticotrophs in clinically normal dogs. In instances of corticotroph adenoma, hypertrophy of individual corticotrophs induced by mitotane may greatly facilitate enlargement of the pituitary gland and increases in ACTH secretion.  相似文献   

15.
Forty-three dogs without evidence of endocrine disease that underwent spinal or abdominal magnetic resonance imaging (MRI) for clinical reasons were studied. Because the procedures were not optimized for inclusion of the adrenal glands, they were not always visible in all planes. Eighty-five of the 86 adrenal glands were seen and only the left gland in a 6-month-old Irish wolfhound could not be found. The right adrenal gland lay cranial to the left in all of the animals in which both glands were seen. The best landmarks for localization of the glands were vascular; both adrenal glands were always cranial to the ipsilateral renal vessels and in the region of the celiac and cranial mesenteric arteries. Various measurements were made on all the available scan planes. In some dogs the whole adrenal gland was difficult to visualize clearly, and this hindered the measuring process, especially when the right adrenal gland was in close contact with the caudal vena cava. The adrenal glands were mainly linear in shape but also had a variable degree of modification of their poles, especially the cranial pole of the right adrenal gland, which tended to be consistently wider and to present different shapes (rounded, arrowhead, inverted P, hook-shaped, triangular, or dome-shaped). Two main patterns of signal intensity were seen on fast spin echo (FSE) sequences (T2-weighted, T1-weighted, and T1-weighted after administration of a paramagnetic contrast medium): homogeneous and hypointense to surroundings or a corticomedullary type pattern with a hyperintense central area surrounded by a hypointense rim of tissue. The outline of the left adrenal gland was always very clear. The clarity of outline of the right adrenal gland was more variable, especially if it was in contact with the liver or the caudal vena cava. It was felt that the amount of retroperitoneal fat was not as important as stated in the human literature for visualization of the adrenal glands and that with an appropriate selection of scan planes and pulse sequences good assessment of the adrenal glands can be performed with MRI in canine patients.  相似文献   

16.
The objective of this retrospective study was to estimate using magnetic resonance imaging the size range of the pituitary gland in cats who had no evidence of pituitary disease. The pituitary gland was measured from transverse and sagittal magnetic resonance postgadolinium T1-weighted images in 17 cats. The cats were 0.83 to 15 years of age and weighed between 2.9 and 6.5 kg. Linear pituitary measurements were performed on a dedicated workstation using electronic calipers. Mean (+/- standard deviation) pituitary gland length was 0.54 cm (+/- 0.06 cm) and mean width was 0.50 cm (+/- 0.08 cm). Mean pituitary gland height measured on sagittal images was 0.34 cm (+/- 0.05) and measured on transverse images was 0.32 cm (+/- 0.04 cm). Mean pituitary volume was 0.05 cm3 (+/- 0.01 cm3). There was no significant correlation between cat weight (kg) and pituitary volume or age and pituitary volume. The pituitary gland appearance varied on pre- and postcontrast T1-weighted images. On the precontrast images, the majority of pituitary glands had a mixed signal intensity. On postcontrast images, uniform pituitary gland enhancement was seen commonly.  相似文献   

17.
This retrospective analysis documented the magnetic resonance imaging (MRI) appearance of normal salivary glands based on 101 studies in dogs with no detectable disease in the splanchnocranium. Surface, signal intensity, homogeneity, structure, symmetry and the relationship of glands to surrounding tissues were noted, and gland topography was assessed with E12 plastinated embedded sections. Signal intensity of salivary glands was isointense (7-40%) to hyperintense (60-90%) to muscle tissue on T1- and hyperintense on T2-weighted images. Salivary glands had an increased T1 signal after contrast medium was applied. Salivary gland structure appeared homogeneous in mandibular and major sublingual glands and heterogeneous in zygomatic and parotid glands. Consistent landmarks were the external auditory canal for parotid glands, the digastric muscle for mandibular and major sublingual glands, and the pterygopalatine fossa for zygomatic glands. The minor sublingual and ventral buccal glands could not be localized with low-field MRI.  相似文献   

18.
The purpose of this study was to determine the optimal window level and width for accurate measurement of pituitary gland height in a phantom. A phantom, mimicking the appearance of the pituitary gland, was made by using the base of a canine skull immersed in buttermilk. Seven different-sized cylindrical pieces of cheese were made and the real diameter of each sample was measured by using a caliper. The cheese was then placed in the pituitary fossa, and 2-mm thick contiguous computed tomography (CT) slices were acquired. The height of the cheese was measured using electronic calipers with different window width and level (WW-WL) settings. The mean difference between CT and manual caliper measurements and concordance correlation coefficients were calculated for all settings. CT measurements underestimated manual caliper measurements with all settings, but the smallest difference (0.5 mm) was obtained with a 250-80 window. Concordance coefficients ranged from 0.699 to 0.820, with the maximum concordance coefficient obtained with a 250-80 window. A second series of measurements using a different window setting for the brain-pituitary gland edge (WW-WL: 250-80) and for the bone-pituitary gland edge (WW-WL: 250-240) resulted in a reduction in the mean difference (0.1 mm) and an increase in the concordance coefficient (0.836). It was concluded that underestimation of the height of the pituitary gland on CT images is most likely due to erroneous placement of the edge of the basisphenoid bone using a low level and a narrow window.  相似文献   

19.
OBJECTIVE: To determine the contrast enhancement pattern of the pituitary gland in healthy dogs via dynamic computed tomography (CT). ANIMALS: 17 dogs. PROCEDURE: With each dog in sternal recumbency, transverse CT scans were made perpendicular to the skull base from the rostral clinoid processes to the dorsum sellae. At the position of the image that contained the largest cross section of the pituitary gland, a series of 9 to 11 scans was made during and after IV injection of contrast medium (dynamic CT scans). The contrast enhancement pattern of the pituitary gland and surrounding arteries was assessed visually and by use of time-density curves. RESULTS: After strong enhancement of the maxillary arteries, the intracavernous parts of the internal carotid arteries, and the communicating arteries of the arterial cerebral circle, there was a strong enhancement of the central part of the pituitary gland followed by enhancement of its peripheral part. On the last images of the dynamic series of the pituitary gland, the central part was hypodense, compared with the peripheral part. Time-density curves confirmed an early, strong enhancement of the central part and a delayed, less strong enhancement of the peripheral part of the gland. CONCLUSIONS AND CLINICAL RELEVANCE: The difference in enhancement between the central and peripheral parts of the pituitary gland was attributable to a difference in vascularization of the neurohypophysis and adenohypophysis, respectively. Distortion or disappearance of the strong central enhancement (pituitary flush) may be used for the detection and localization of pituitary abnormalities in the adenohypophysis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号