首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This prospective study was designed to investigate D-dimer concentrations in clinically healthy dogs, clinically ill dogs without thromboembolic disease (TE), and dogs with TE. The goals of this study were to determine whether the coagulation cascade is activated in nonembolic metabolic and inflammatory conditions and whether differentiation from TE is possible. Group 1 consisted of 30 clinically healthy dogs presented for routine care. Group 2 consisted of 67 clinically ill dogs without TE. This group was subdivided into the following categories: postoperative surgical procedures, congestive heart failure, renal failure, hepatic disease, and neoplastic disease. Group 3 consisted of 20 dogs diagnosed with TE. A CBC and a measurement of prothrombin time (PT), activated partial thromboplastin time (PTT), fibrinogen degradation product (FDP) concentration, and plasma D-dimer concentration was performed on dogs in all groups. D-dimer concentrations were highest in dogs with TE; next highest was the hepatic disease group. Only these 2 groups had median D-dimer concentrations markedly different from clinically healthy dogs. The frequency of platelet abnormalities was markedly greater for the TE and neoplastic disease groups. The sensitivity of D-dimer concentrations >500 ng/mL for predicting TE was 100%; however, the specificity of D-dimer for TE at that concentration was 70%. The specificity of D-dimer concentrations >1,000 ng/mL to predict TE was 94% (sensitivity, 80%), and the specificity of D-dimer concentrations >2,000 ng/mL was 98.5% (sensitivity, 36%). FDPs were not high in any TE patient; thus, they may be an insensitive indicator of thromboembolism, with or without overt disseminated intravascular coagulation (DIC).  相似文献   

2.
OBJECTIVE: To evaluate a canine D-dimer point-of-care (cD-d POC) test kit for use in healthy dogs and dogs with disseminated intravascular coagulation (DIC), thromboembolic disease (TED), and hemorrhage. ANIMALS: 12 healthy dogs, 18 dogs with DIC, 23 dogs with TED (19 acute and 4 chronic), and 18 dogs with hemorrhage. PROCEDURE: The cD-d POC, canine D-dimer ELISA (cD-d ELISA), human D-dimer latex agglutination (hD-d LA), and fibrin degradation product (FDP) tests were performed on citrated plasma. RESULTS: All healthy dogs had negative cD-d POC test results and mean cD-d ELISA value of 0.2 U/mL. All dogs with DIC had positive cD-d POC test results and mean cD-d ELISA value of 44 U/mL. Dogs with acuteTED had a mean cD-d ELISA value of 34 U/mL, and 17 of 19 had positive cD-d POC test results. Mean cD-d ELISA value in dogs with hemorrhage was 14 units/mL, and 15 of 18 had positive cD-d POC test results. The cD-d ELISA values in dogs with hemorrhage were significantly higher than those of healthy dogs but lower than those of dogs with DIC and acute TED. The cD-d POC, cD-d ELISA, and hD-d LA tests were comparable in differentiating healthy dogs from dogs with DIC, acute TED, or hemorrhage and appeared to be superior to measurement of FDPs. CONCLUSIONS AND CLINICAL RELEVANCE: The cD-d POC test kit can be quickly and easily used and reliably detects dogs with DIC or acute TED. Positive results may also be seen in dogs with internal hemorrhage.  相似文献   

3.
Background: Fibrin(ogen) degradation products (FDPs) and D‐dimer are sensitive indicators of excessive fibrinolysis due to disseminated intravascular coagulation (DIC) in dogs. To the authors' knowledge, latex‐agglutination–based plasma FDP and D‐dimer assays have not been validated for use in horses. Objectives: To determine: 1) sensitivity and specificity of latex‐agglutination serum and plasma FDP and D‐dimer assays for diagnosis of DIC; and 2) their prognostic value in horses with severe colic. Methods: At hospital admission and 24 hours later, blood was collected from 30 healthy horses and 20 horses with severe colic. Horses fulfilling predefined laboratory criteria of DIC were enrolled, and their data were subcategorized by survival for analysis. Platelet counts were determined and coagulation panel testing was performed. Serum and plasma FDP concentrations were measured using separate latex agglutination kits. Plasma D‐dimer concentration was measured using 3 latex agglutination kits and a card immunofiltration test. Test sensitivity and specificity results were determined for healthy horses and those with colic. Median test values were compared between colic survivors and nonsurvivors to evaluate the prognostic usefulness of all tests. Results: Performance characteristics varied among assays and kit suppliers. The FDP assays had low sensitivity (<40%), whereas the most accurate D‐dimer kit had 50% sensitivity and 97% specificity. High D‐dimer concentration was the third most common hemostatic abnormality in horses with colic. Median antithrombin (AT) activity was significantly lower and activated partial thromboplastin time (aPTT) was significantly longer in nonsurvivors than survivors. Conclusions: Commercial latex‐agglutination D‐dimer assays might prove useful as adjunctive tests for the diagnosis of DIC in horses with severe colic; however FDP assays are invalid for this purpose. Low AT activity and prolonged aPTT at admission are associated with a poor prognosis in this patient population.  相似文献   

4.
The concentration of C-reactive protein (CRP) was measured in effusions from 50 dogs to assess the potential for measuring this protein to differentiate body cavity fluids. The effusions were classified as either transudates, modified transudates or exudates according to their total protein concentration, total nucleated cell count, cytological findings and aetiology, and the concentration of CRP was determined by a time-resolved immunofluorometric assay. There were significant differences between the concentrations of CRP in the three types of effusion; the highest concentrations were observed in the exudates (4.47 to 54.59 microg/ml), the lowest were in the transudates (0.0094 to 7.87 microg/ml), and the modified transudates contained intermediate concentrations of CRP (0.045 to 10.78 microg/ml). A cut-off value of 4 microg/ml had a sensitivity of 100 per cent and a specificity of 94.4 per cent for differentiating transudates from exudates, and a cut-off value of 11 microg/ml had a sensitivity of 88.2 per cent and a specificity of 100 per cent for distinguishing modified transudates from exudates. However, a cut-off value of 1 microg/ml had a lower sensitivity (80 per cent) and an unacceptably low specificity (66.7 per cent) for differentiating transudates from modified transudates.  相似文献   

5.
Abstract: An increased concentration of fibrin(ogen) degradation products (FDPs) commonly is used in conjunction with other hemostatic test abnormalities to identify patients with disseminated intravascular coagulation (DIC). Positive FDP results, however, have been observed in dogs without clinical evidence of DIC. The purpose of this study was to evaluate FDP concentrations in a group of clinically ill dogs with a variety of disorders. Dogs included in the study had the following hemostatic parameters evaluated: prothrombin time, activated partial thromboplastin time, fibrinogen concentration, platelet count, and FDP concentration. Two rapid latex agglutination methods were compared for detecting FDP in serum samples (Thrombo-Wellcotest, International Murex Technologies Corp) and plasma samples (FDP Plasma, American Bioproducts Inc). Results of the serum FDP method were positive in 8% (4/50) of the dogs tested: 3 with DIC and 1 with immune-mediated hemolytic anemia and liver disease. Results of the plasma FDP test were positive in 60% (30/50) of the animals tested: 6 with DIC, 3 with confirmed thrombosis, and 21 with a variety of conditions, including neoplasia, immune-mediated hemolytic anemia, pancreatitis, gastric dilatation-volvulus, heat stroke, severe trauma, sepsis, protein-losing nephropathy, liver disease, hyperadrenocorticism, and chronic heart failure. Because the plasma FDP test was positive more frequently than the serum FDP test in ill dogs, it may be more sensitive for the detection of canine FDP.  相似文献   

6.
OBJECTIVE: To evaluate semiquantitative and quantitative assays for microalbuminuria and determination of the urine albumin-creatinine (UAC) ratio in detection of systemic disease in dogs without overt proteinuria. DESIGN: Prospective study. ANIMALS: 408 dogs. PROCEDURES: Urine samples that had been obtained from dogs for which a complete medical record was available and in which results of a dipstick test for urine protein were negative were evaluated. Urine protein-creatinine ratios (cutoff values, 0.5 and 0.1), semiquantitative and quantitative microalbuminuria values (cutoff value, 1 mg/dL), and UAC ratios (cutoff values, 100 and 200 mg/g) were determined. Clinical diagnoses rendered within 3 months of enrollment in the study were recorded. Sensitivity and specificity were determined with disease status serving as the standard. Associations with clinical diagnosis, sex, age, BUN and serum creatinine concentrations, blood pressure, results of bacterial culture of urine, temperature, pyuria, hematuria, and bacteriuria were evaluated by use of logistic regression analysis. RESULTS: 48 dogs were healthy, and 360 had at least 1 disease. Significant associations were detected between age, presence of disease, presence of neoplastic disease, BUN and serum creatinine concentrations, and hematuria and results of 1 or both of the microalbuminuria assays. CONCLUSIONS AND CLINICAL RELEVANCE: Microalbuminuria was associated with underlying disease. The sensitivity and specificity of the semiquantitative microalbuminuria test for detection of systemic disease were superior to those of other tests. Microalbuminuria testing in conjunction with other screening procedures may increase diagnosis of subclinical disease, but a prospective study in which the predictive values of screening tests are evaluated, with and without microalbuminuria determination, is needed.  相似文献   

7.
The sensitivities and specificities of 3 commercial serum fibrin(ogen) degradation product (FDP) kits and 1 plasma FDP kit for the detection of FDPs in dogs were determined. Blood was collected for measurement of serum and plasma FDP concentrations from 30 healthy dogs and from 20 dogs that fulfilled clinical and laboratory criteria for disseminated intravascular coagulation. To determine the effect of hemolysis on FDP results, blood was collected simultaneously into Bothrops atrox venom-based and thrombin-based serum collection tubes for measurement of FDPs using a single serum FDP kit. The sensitivity (80-95%) and specificity (90-100%) for a positive or negative FDP result, regardless of concentration, was similar for all kits. Kits yielded discordant results in individual dogs and FDP concentrations obtained from 1 serum FDP kit were consistently higher than those from the other kits. Serum prepared from venom-based collection tubes was significantly more hemolyzed than serum prepared from thrombin-based collection tubes or citrated plasma. Hemolysis did not affect the FDP results. On the basis of these results, we conclude that commercial latex agglutination kits for detection of FDPs in serum and plasma samples from human patients are valid for use in dogs. The plasma FDP assay is a viable alternative to currently used serum FDP assays and has the advantage of using a single (citrated plasma) sample for measuring coagulation parameters and FDP concentration.  相似文献   

8.
OBJECTIVE: To evaluate the use of EDTA tubes for collection of blood samples for assays of secondary hemostasis in dogs. ANIMALS: 108 dogs of various ages, breeds, and sexes (19 healthy and 89 with abnormalities of secondary hemostasis). PROCEDURES: Blood samples were collected via cephalic venipuncture and transferred to sodium citrate tubes and EDTA tubes. Plasma was harvested from each type of tube for assays of concentrations of fibrinogen and D-dimer as well as prothrombin time, activated partial thromboplastin time, and antithrombin activity. Intra-assay and interassay precision and correlation coefficients for all hemostatic tests were calculated for each type of plasma sample. The effect of storage conditions on assay results for the 2 types of plasma samples was also evaluated. RESULTS: Results of hemostatic tests were highly correlated between citrated and EDTA-treated plasma samples. Intra-assay imprecision for all hemostatic tests with the exception of D-dimer concentration was < 10% for both citrated and EDTA-treated plasma samples; interassay imprecision was higher for EDTA-treated versus citrated plasma samples. Storage of plasma samples for 1 hour did not result in significantly different assay results for either type of plasma sample, but storage for 2 hours significantly affected values for EDTA-treated plasma samples. CONCLUSIONS AND CLINICAL RELEVANCE: Although evaluation of the sensitivity and specificity of hemostatic tests that use EDTA-treated plasma samples is required, EDTA may be a suitable alternative to sodium citrate as an anticoagulant for use in hemostatic testing in conditions in which tests could be performed within 1 hour after sample collection.  相似文献   

9.
Plasma N-terminal pro-atrial natriuretic peptide (NT-proANP) concentration increases with progression of myxomatous mitral valve disease (MMVD) in dogs. This multicentre, prospective study compared plasma NT-proANP, N-terminal pro-brain natriuretic peptide (NT-proBNP), ANP, and cardiac troponin I (cTnI) concentrations in dogs with MMVD for their characteristics and discriminatory ability to detect cardiac dilatation and congestive heart failure (CHF). Thirty-six healthy dogs and 69 dogs with MMVD were included. Clinical variables were obtained via physical examination, thoracic radiography, and echocardiography. The discriminatory ability of each cardiac biomarker (CB) to determine the presence or absence of cardiac dilatation (event 1) and CHF (event 2) was evaluated using the receiver operating characteristic curves. Plasma NT-proANP, NT-proBNP, and ANP concentrations showed a significant association with the left atrium/aorta ratio (P<0.01). The area under the curve of plasma NT-proANP and NT-proBNP concentrations were 0.72 and 0.75, respectively in event1 and 0.72 and 0.76, respectively in event2. Plasma NT-proANP and NT-proBNP concentrations showed sensitivity 80.0 and 80.0%; specificity 67.6 and 64.7% in event1 (cutoff value; 8,497.81 pg/ml and 1,453.00 pmol/l, respectively) and sensitivity 85.7 and 81.0%; specificity 60.4 and 64.6% in event2 (cutoff value; 8,684.33 pg/ml and 1,772.00 pmol/l, respectively). In dogs with MMVD, plasma NT-proANP, NT-proBNP, and ANP concentrations increase with left atrial enlargement. Particularly, plasma NT-proANP and NT-proBNP concentrations appeared to be equally useful in the discriminatory ability to detect cardiac dilatation and CHF.  相似文献   

10.
Evidence of hypercoagulability in dogs with parvoviral enteritis   总被引:9,自引:0,他引:9  
OBJECTIVE: To determine whether dogs with naturally occurring canine parvoviral (CPV) enteritis have laboratory evidence of hypercoagulability. DESIGN: Case-control study. Animals-9 dogs with naturally occurring CPV enteritis and 9 age-matched control dogs. PROCEDURE: Blood was collected from all dogs within 24 hours of admission for thromboelastography (TEG) and determination of activated partial thromboplastin time (aP-TT), prothrombin time (PT), antithrombin III (AT) activity, and fibrinogen concentration. Fibrin-fibrinogen degradation product (FDP) concentration, D-dimer concentration, and platelet count were obtained in dogs with CPV enteritis only. Records were reviewed for evidence of thrombosis or phlebitis. RESULTS: All 9 dogs with CPV enteritis had evidence of hypercoagulability, determined on the basis of significantly increased TEG maximum amplitude and decreased AT activity. Fibrinogen concentration was significantly higher in dogs with CPV enteritis than in control dogs. The aPTT was moderately prolonged in dogs with CPV enteritis, and FDP concentration was < 5 mg/ml in 7 of 9 dogs. No dogs had a measurable D-dimer concentration. Platelet counts were within reference range. Four of 9 dogs had clinical evidence of venous thrombosis or phlebitis associated with catheters. One dog had multifocal splenic thrombosis identified at necropsy. CONCLUSIONS AND CLINICAL RELEVANCE: Dogs with CPV enteritis have a high prevalence of clinical thrombosis or phlebitis and laboratory evidence of hypercoagulability without disseminated intravascular coagulopathy. Thromboelastography may help identify hypercoagulable states in dogs.  相似文献   

11.
Abstract: D-dimer is a neoantigen formed when thrombin initiates the transformation of fibrinogen to fibrin; it is derived from plasmin digestion of cross-linked fibrin. In human medicine, the usefulness of this analyte in diagnosing disseminated intravascular coagulation (DIC) has been assessed in patients fulfilling the clinical and laboratory requirements for this disorder. In canine medicine, the use of D-dimer is relatively new. Detailed studies are needed to understand the relationship between D-dimer concentration in plasma and DIC status in dogs. We validated a D-dimer immunoturbidimetric assay (Tina-quant [a] D-Dimer, Boehringer Mannheim) in canine citrated plasma samples. Intra-assay and interassay variability (coefficient of variation) was 5.63% and 8.82%, respectively. The assay was linear, using 2 samples with low and high D-dimer concentrations (r = .996 and .998). Accuracy was 102.2% and 95.7% based on a recovery study in which 2 samples were assessed. Reference values for D-dimer were established using 70 healthy dogs that were assessed clinically and evaluated on the basis of a complete laboratory workup. The reference range was set between 0.02 and 0.28 μg/mL (chi-square test for normal distribution, P > .05).  相似文献   

12.
Adrenomedullin (AM), a peptide identified to have vasodilating and natriuretic effects, is involved in the regulation of the cardiovascular system. To evaluate plasma AM concentration in dogs with myxomatous mitral valvular disease (MMVD), and to investigate the associations between the concentrations of plasma AM and natriuretic peptides and the echocardiographic data, we evaluated plasma AM concentrations in 31 healthy control dogs and 57 dogs with MMVD. Plasma AM concentrations in dogs with MMVD were higher than that in the control subjects. The plasma AM concentration increased in conjunction with the severity of heart failure according to the International Small Animal Cardiac Health Council (ISACHC). The AM concentrations were 25.1 ± 5.0 fmol/ml (ISACHC class Ia), 29.9 ± 11.0 fmol/ml (ISACHC class Ib), 43.4 ± 19.8 fmol/ml (ISACHC class II) and 73.5 ± 21.7 fmol/ml (ISACHC class III) and 7.5 ± 5.1 fmol/ml (control group), respectively. The receiver operating characteristic curve indicated an area of 0.93 (95% CI, 0.8801-0.9889; <0.0001), a cutoff value of 30.5 fmol/ml, a sensitivity of 87.1%, and a specificity of 82.5% for the determination of congestive heart failure. Plasma AM concentrations correlated with atrial natriuretic peptide concentrations, LA/Ao ratio, and left ventricular diameter. In conclusion, AM may be a potential diagnostic marker for canine MMVD and possibly plays a pathophysiological role in collaboration with the other neurohumoral factors such as natriuretic peptides.  相似文献   

13.
OBJECTIVE: To determine whether basal serum or plasma cortisol concentration can be used as a screening test to rule out hypoadrenocorticism in dogs. DESIGN: Retrospective case-control study. ANIMALS: 110 dogs with nonadrenal gland illnesses and 13 dogs with hypoadrenocorticism. PROCEDURES: Sensitivity and specificity of basal serum or plasma cortisol concentrations of either 2 microg/dL that are not receiving corticosteroids, mitotane, or ketoconazole are highly unlikely to have hypoadrenocorticism. However, if the basal cortisol concentration is 相似文献   

14.
OBJECTIVE: To assay concentrations of cartilage oligomeric matrix protein (COMP) in canine sera and synovial fluid (SF), to compare COMP concentrations in clinically normal dogs and dogs with joint disease, and to analyze changes in COMP concentrations in dogs with experimentally induced acute synovitis. ANIMALS: 69 control dogs without joint disease, 23 dogs with naturally occurring aseptic arthropathy, and 6 dogs with experimentally induced synovitis. PROCEDURE: Serum (n = 69) and SF (36) were obtained from control dogs. Samples of serum (n = 23) and SF (13) were obtained from dogs with naturally occurring aseptic arthropathy with or without radiographic features of osteoarthritis (OA). Serum and SF were obtained before and 1, 2, 3, and 7 days after induction of synovitis. The COMP concentrations were determined by use of an inhibition ELISA that had canine cartilage COMP and monoclonal antibody against human COMP. RESULTS: Concentrations of COMP in serum and SF of control dogs were 31.3+/-15.3 and 298.7+/-124.7 microg/ml, respectively. In naturally occurring OA, COMP concentrations in serum (44.9+/-177 microg/ml) and SF (401.7+/-74.3 microg/ml) were significantly higher than corresponding concentrations in control dogs. The COMP concentration in SF peaked 24 and 48 hours after induction of synovitis, whereas concentration in serum peaked on day 3. CONCLUSIONS AND CLINICAL RELEVANCE: These results supported the hypothesis that COMP concentration in serum and SF of dogs may be altered after cartilage degradation or synovitis. Measurement of COMP concentrations can be useful when differentiating arthropathies in dogs.  相似文献   

15.
OBJECTIVE: To evaluate the use of immunofluorescence asssays for perinuclear antineutrophilic cytoplasmic antibodies (pANCAs) and antibodies to Saccharomyces cerevisiae (ASCAs) in dogs with inflammatory bowel disease (IBD) and assess the clinical value of these serologic markers of the disease. ANIMALS: 39 dogs with IBD, 18 dogs with acute diarrhea, 19 dogs with chronic non-IBD-associated diarrhea, 26 healthy dogs of various breeds and age, and 22 healthy young working dogs. PROCEDURE: Sera obtained from the dogs in each group were added to canine granulocyte- and Saccharomyces cerevisiae-mounted slides for detection of pANCAs and ASCAs via immunofluorescence techniques. Sensitivity and specificity (with 95% confidence intervals [CIs]) were calculated for the group of dogs with IBD versus each of the 2 groups of healthy dogs, the group of dogs with acute diarrhea, and the group of dogs with chronic non-IBD-associated diarrhea. RESULTS: Among the 39 dogs with IBD, 20 yielded positive results via the pANCA assay (sensitivity, 0.51 [95% CI, 0.35 to 0.67]) and 17 yielded positive results via the ASCA assay (sensitivity, 0.44 [95% CI, 0.22 to 0.69]). The specificity of the pANCA assay in the 4 groups of non-IBD-affected dogs ranged from 0.83 (95% CI, 0.85 to 0.96) to 0.95 (95% CI, 0.72 to 1.00). CONCLUSIONS AND CLINICAL RELEVANCE: Immunofluorescence assays for pANCA and ASCA appear to be useful for the detection of IBD in dogs. The pANCA immunofluorescence assay had high specificity for canine IBD, and pANCAs appear to be accurate markers of intestinal inflammation.  相似文献   

16.
OBJECTIVE: To develop and validate an ELISA for measurement of serum canine pepsinogen A (cPG A) as a diagnostic marker of gastric disorders in dogs and to measure serum cPG A in healthy dogs after food deprivation and after feeding. SAMPLE POPULATION: Sera from 72 healthy dogs. PROCEDURE: A sandwich ELISA was developed and validated. The reference range for serum concentrations of cPG A was determined in 64 healthy dogs. Postprandial changes in serum concentrations of cPG A were evaluated in 8 healthy dogs. RESULTS: Assay sensitivity was 18 microg/L, and the maximum detectable concentration was 1,080 microg/L. The observed-to-expected ratio (O:E) for 3 serial dilutions of 3 serum samples ranged from 69.3 to 104.1%. The O:E for 3 serum samples spiked with 8 concentrations of cPG A ranged from 58.8 to 120.4%. Coefficients of variation for intra- and interassay variability of 3 serum samples ranged from 7.6 to 11.9% and from 10.1 to 13.1%, respectively. Mean +/- SD serum concentration of cPG A in healthy dogs was 63.8 +/- 31.0 microg/L and the reference range was 18 to 129 microg/L. Significant increases in serum concentrations of cPG A were observed between 1 and 7 hours after feeding. CONCLUSIONS AND CLINICAL RELEVANCE: The ELISA for measuring cPG A was sufficiently sensitive, linear, accurate, precise, and reproducible for clinical use. Serum concentrations of cPG A increase substantially after feeding, which should be taken into account when conducting clinical studies.  相似文献   

17.
BACKGROUND: Current coagulation tests lack sensitivity and detect disseminated intravascular coagulation (DIC) only when it is severe. Measurement of antithrombin (AT) activity and D-dimer concentration permits early diagnosis and more precise classification of coagulopathies in some species. OBJECTIVES: The objectives of this study were to validate and determine the diagnostic utility of a chromogenic AT assay and an immunoturbidimetric D-dimer assay for the diagnosis of DIC in cats. METHODS: Citrated plasma samples were collected from 30 healthy cats, 30 ill cats, and 13 cats with cardiomyopathy. Partial thromboplastin time, prothrombin time, fibrin(ogen) degradation products, platelet concentration, and erythrocyte morphology were determined on all samples to document the presence or the absence of DIC. AT activity and D-dimer concentration were then measured. RESULTS: The chromogenic AT assay was linear and precise. Mean AT activity was higher in ill cats and cats with cardiomyopathy compared with healthy cats, but the difference was only significant in ill cats (P = .003). Seven cats met the criteria for DIC. Of the cats with DIC, 2 had decreased AT activity, 1 had increased AT activity, and 4 had AT activities within normal limits. The immunoturbidimetric D-dimer assay did not appear to accurately measure feline D-dimer. CONCLUSIONS: The chromogenic AT assay appeared to measure AT in cats but was not useful for the diagnosis of DIC. AT may be an acute phase reactant in cats. The immunoturbidimetric D-dimer assay was not useful for the diagnosis of DIC in cats.  相似文献   

18.
BACKGROUND: Thrombosis and arterial thromboembolism are frequent complications of feline cardiomyopathy, especially when associated with left atrial enlargement. Markers of activated coagulation may be used to evaluate the coagulation status of cats with hypertrophic cardiomyopathy (HCM) in relation to left atrial size. OBJECTIVES: The objective of this study was to compare plasma concentrations of thrombin-antithrombin complex (TAT), D-dimer, and fibrin degradation products (FDP) between clinically healthy cats and cats with HCM. Prothrombin time (PT), activated partial thromboplastin time (aPTT), and antithrombin activity were also compared and the association between left atrial (LA) size and coagulation results in cats with HCM was evaluated. METHODS: Blood samples from 19 clinically healthy cats and 20 cats with HCM were obtained. All cats with HCM were asymptomatic and had no signs of heart failure. LA diameter and LA to proximal aortic (Ao) diameter ratio (LA:Ao) were determined by echocardiography. RESULTS: Reference intervals for D-dimer and TAT concentrations in plasma of healthy cats were established as 0.09-0.32 microg/mL and 2.0-20.0 microg/L, respectively. TAT, D-dimer, and FDP concentrations were increased in 5, 3, and 2 cats with HCM, respectively. TAT and D-dimer concentrations, and PT and aPTT were not significantly different between groups. Antithrombin activity was significantly decreased in cats with HCM (P=.03) despite marked range overlap. LA and LA:Ao were not correlated with coagulation results. CONCLUSIONS: Laboratory evidence of hypercoagulability was found in 45% of cats with HCM. Left atrial size was not associated with laboratory evidence of hypercoagulability. Association between coagulation markers and risk of thrombosis has yet to be evaluated in cats with HCM.  相似文献   

19.
D-dimer is formed during thrombus formation when factor XIIIa crosslinks the terminal D-domains of fibrin. The D-dimer epitope is exposed when the thrombus is lysed by plasmin. Thus, D-dimer represents both thrombin and plasmin activation and is specific for fibrinolysis. D-dimer concentrations are increased in dogs with DIC or other thromboembolic disorders, but because D-dimer is an indicator of physiologic or pathologic fibrinolysis, values are elevated in other conditions associated with fibrinolysis, including orthopedic surgery, neoplasia, and internal hemorrhage. It can be used as an ancillary test for the diagnosis of DIC but is not recommended as a sole test for this purpose. D-dimer has the potential to be a useful laboratory test for the detection of pulmonary thromboembolism in dogs. Further studies are needed to determine the appropriate applications for this test in veterinary patients to aid in clinical decision making, treatment, and patient care.  相似文献   

20.
OBJECTIVE: To evaluate the use of measuring plasma concentrations of atrial natriuretic peptide (ANP), B-type natriuretic peptide (BNP), and cardiac troponin-I (cTnI) to detect dogs with occult dilated cardiomyopathy (DCM). ANIMALS: 118 client-owned dogs. PROCEDURES: Dogs were prospectively examined by use of ECG; echocardiography; and evaluation of concentrations of ANP, BNP, and cTnI. Occult DCM was diagnosed by evaluation of echocardiographic left ventricular dimensions and detection of ventricular arrhythmias on ECG. Sensitivity and specificity of assays for measurement of plasma concentrations of ANP, BNP, and cTnI to detect dogs with occult DCM were determined. RESULTS: Occult DCM was diagnosed in 21 dogs. A concentration of > 6.21 pg/mL for BNP had a sensitivity of 95.2% and specificity of 61.9% for identifying dogs with occult DCM. In contrast, concentrations of ANP and cTnI had relatively low predictive values. CONCLUSIONS AND CLINICAL RELEVANCE: Blood-based screening for occult DCM in dogs can be accomplished by use of a BNP assay. Additional studies should be performed to optimize this method of screening dogs to detect occult DCM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号