 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background: Fibrin(ogen) degradation products (FDPs) and D‐dimer are sensitive indicators of excessive fibrinolysis due to disseminated intravascular coagulation (DIC) in dogs. To the authors' knowledge, latex‐agglutination–based plasma FDP and D‐dimer assays have not been validated for use in horses. Objectives: To determine: 1) sensitivity and specificity of latex‐agglutination serum and plasma FDP and D‐dimer assays for diagnosis of DIC; and 2) their prognostic value in horses with severe colic. Methods: At hospital admission and 24 hours later, blood was collected from 30 healthy horses and 20 horses with severe colic. Horses fulfilling predefined laboratory criteria of DIC were enrolled, and their data were subcategorized by survival for analysis. Platelet counts were determined and coagulation panel testing was performed. Serum and plasma FDP concentrations were measured using separate latex agglutination kits. Plasma D‐dimer concentration was measured using 3 latex agglutination kits and a card immunofiltration test. Test sensitivity and specificity results were determined for healthy horses and those with colic. Median test values were compared between colic survivors and nonsurvivors to evaluate the prognostic usefulness of all tests. Results: Performance characteristics varied among assays and kit suppliers. The FDP assays had low sensitivity (<40%), whereas the most accurate D‐dimer kit had 50% sensitivity and 97% specificity. High D‐dimer concentration was the third most common hemostatic abnormality in horses with colic. Median antithrombin (AT) activity was significantly lower and activated partial thromboplastin time (aPTT) was significantly longer in nonsurvivors than survivors. Conclusions: Commercial latex‐agglutination D‐dimer assays might prove useful as adjunctive tests for the diagnosis of DIC in horses with severe colic; however FDP assays are invalid for this purpose. Low AT activity and prolonged aPTT at admission are associated with a poor prognosis in this patient population.  相似文献   

2.
OBJECTIVE: To evaluate a canine D-dimer point-of-care (cD-d POC) test kit for use in healthy dogs and dogs with disseminated intravascular coagulation (DIC), thromboembolic disease (TED), and hemorrhage. ANIMALS: 12 healthy dogs, 18 dogs with DIC, 23 dogs with TED (19 acute and 4 chronic), and 18 dogs with hemorrhage. PROCEDURE: The cD-d POC, canine D-dimer ELISA (cD-d ELISA), human D-dimer latex agglutination (hD-d LA), and fibrin degradation product (FDP) tests were performed on citrated plasma. RESULTS: All healthy dogs had negative cD-d POC test results and mean cD-d ELISA value of 0.2 U/mL. All dogs with DIC had positive cD-d POC test results and mean cD-d ELISA value of 44 U/mL. Dogs with acuteTED had a mean cD-d ELISA value of 34 U/mL, and 17 of 19 had positive cD-d POC test results. Mean cD-d ELISA value in dogs with hemorrhage was 14 units/mL, and 15 of 18 had positive cD-d POC test results. The cD-d ELISA values in dogs with hemorrhage were significantly higher than those of healthy dogs but lower than those of dogs with DIC and acute TED. The cD-d POC, cD-d ELISA, and hD-d LA tests were comparable in differentiating healthy dogs from dogs with DIC, acute TED, or hemorrhage and appeared to be superior to measurement of FDPs. CONCLUSIONS AND CLINICAL RELEVANCE: The cD-d POC test kit can be quickly and easily used and reliably detects dogs with DIC or acute TED. Positive results may also be seen in dogs with internal hemorrhage.  相似文献   

3.
Abstract: An increased concentration of fibrin(ogen) degradation products (FDPs) commonly is used in conjunction with other hemostatic test abnormalities to identify patients with disseminated intravascular coagulation (DIC). Positive FDP results, however, have been observed in dogs without clinical evidence of DIC. The purpose of this study was to evaluate FDP concentrations in a group of clinically ill dogs with a variety of disorders. Dogs included in the study had the following hemostatic parameters evaluated: prothrombin time, activated partial thromboplastin time, fibrinogen concentration, platelet count, and FDP concentration. Two rapid latex agglutination methods were compared for detecting FDP in serum samples (Thrombo-Wellcotest, International Murex Technologies Corp) and plasma samples (FDP Plasma, American Bioproducts Inc). Results of the serum FDP method were positive in 8% (4/50) of the dogs tested: 3 with DIC and 1 with immune-mediated hemolytic anemia and liver disease. Results of the plasma FDP test were positive in 60% (30/50) of the animals tested: 6 with DIC, 3 with confirmed thrombosis, and 21 with a variety of conditions, including neoplasia, immune-mediated hemolytic anemia, pancreatitis, gastric dilatation-volvulus, heat stroke, severe trauma, sepsis, protein-losing nephropathy, liver disease, hyperadrenocorticism, and chronic heart failure. Because the plasma FDP test was positive more frequently than the serum FDP test in ill dogs, it may be more sensitive for the detection of canine FDP.  相似文献   

4.
OBJECTIVE: To evaluate the use of EDTA tubes for collection of blood samples for assays of secondary hemostasis in dogs. ANIMALS: 108 dogs of various ages, breeds, and sexes (19 healthy and 89 with abnormalities of secondary hemostasis). PROCEDURES: Blood samples were collected via cephalic venipuncture and transferred to sodium citrate tubes and EDTA tubes. Plasma was harvested from each type of tube for assays of concentrations of fibrinogen and D-dimer as well as prothrombin time, activated partial thromboplastin time, and antithrombin activity. Intra-assay and interassay precision and correlation coefficients for all hemostatic tests were calculated for each type of plasma sample. The effect of storage conditions on assay results for the 2 types of plasma samples was also evaluated. RESULTS: Results of hemostatic tests were highly correlated between citrated and EDTA-treated plasma samples. Intra-assay imprecision for all hemostatic tests with the exception of D-dimer concentration was < 10% for both citrated and EDTA-treated plasma samples; interassay imprecision was higher for EDTA-treated versus citrated plasma samples. Storage of plasma samples for 1 hour did not result in significantly different assay results for either type of plasma sample, but storage for 2 hours significantly affected values for EDTA-treated plasma samples. CONCLUSIONS AND CLINICAL RELEVANCE: Although evaluation of the sensitivity and specificity of hemostatic tests that use EDTA-treated plasma samples is required, EDTA may be a suitable alternative to sodium citrate as an anticoagulant for use in hemostatic testing in conditions in which tests could be performed within 1 hour after sample collection.  相似文献   

5.
OBJECTIVE: To compare results of 3 commercial heartworm antigen test kits performed on serum samples from dogs infected with low numbers of adult female heartworms. DESIGN: Blinded laboratory evaluation. Sample Population-Serum samples from dogs (n = 208) proven at necropsy to be infected with 1 to 4 adult female heartworms and from dogs (32) without heartworms. PROCEDURE: Samples were sequentially tested with each test kit, following the manufacturers' instructions, by licensed veterinary technicians in private practice who were not aware of infection status of the dogs. The order of test kit evaluations was randomly chosen. For each test kit, sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were evaluated. RESULTS: All tests yielded some false-negative results, and there were significant differences among tests in regard to ability to detect low heartworm burdens. Sensitivity of the test kits ranged from 78 to 84%. For all test kits, sensitivity increased as number of female heartworms increased. All 3 test kits had high specificity (97%). CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that sensitivity of the 3 commercially available heartworm antigen test kits ranged from 78 to 84% when used to test serum samples from dogs with low heartworm burdens, and that sensitivity varied among test kits. For all 3 test kits, specificity was 97%. All 3 test kits yielded false-positive and false-negative results for some dogs with low heartworm burdens.  相似文献   

6.
This prospective study was designed to investigate D-dimer concentrations in clinically healthy dogs, clinically ill dogs without thromboembolic disease (TE), and dogs with TE. The goals of this study were to determine whether the coagulation cascade is activated in nonembolic metabolic and inflammatory conditions and whether differentiation from TE is possible. Group 1 consisted of 30 clinically healthy dogs presented for routine care. Group 2 consisted of 67 clinically ill dogs without TE. This group was subdivided into the following categories: postoperative surgical procedures, congestive heart failure, renal failure, hepatic disease, and neoplastic disease. Group 3 consisted of 20 dogs diagnosed with TE. A CBC and a measurement of prothrombin time (PT), activated partial thromboplastin time (PTT), fibrinogen degradation product (FDP) concentration, and plasma D-dimer concentration was performed on dogs in all groups. D-dimer concentrations were highest in dogs with TE; next highest was the hepatic disease group. Only these 2 groups had median D-dimer concentrations markedly different from clinically healthy dogs. The frequency of platelet abnormalities was markedly greater for the TE and neoplastic disease groups. The sensitivity of D-dimer concentrations >500 ng/mL for predicting TE was 100%; however, the specificity of D-dimer for TE at that concentration was 70%. The specificity of D-dimer concentrations >1,000 ng/mL to predict TE was 94% (sensitivity, 80%), and the specificity of D-dimer concentrations >2,000 ng/mL was 98.5% (sensitivity, 36%). FDPs were not high in any TE patient; thus, they may be an insensitive indicator of thromboembolism, with or without overt disseminated intravascular coagulation (DIC).  相似文献   

7.
Two commercial PRRSV ELISA kits (IDEXX and Bionote) were evaluated for their sensitivity and specificity using 476 PRRS-positive serum samples collected from 7 animal challenge experiments and 1,000 PRRS-negative sera. Both ELISA kits exhibited 100% sensitivity with sera collected 14 to 42 days post-infection, and the results from the kits were highly correlated (R2=0.9207). The specificity of IDEXX or Bionote kit was 99.9% or 99.7%, respectively. In addition, the Bionote ELISA kit was used to examine 100 sera that were determined to be falsely positive either by IDEXX 2XR or 3XR ELISA, and only 7 of these samples were found to be positive. These results indicate that both ELISA kits exhibited similar levels of sensitivity and specificity and would complement one another for the verification of false-positive samples.  相似文献   

8.
OBJECTIVE: To determine sensitivity and specificity of assays of D-dimer concentrations in dogs with disseminated intravascular coagulation (DIC) and healthy dogs and to compare these results with those of serum and plasma fibrin-fibrinogen degradation product (FDP) assays. ANIMALS: 20 dogs with DIC and 30 healthy dogs. PROCEDURE: Semi-quantitative and quantitative D-dimer concentrations were determined by use of latex-agglutination and immunoturbidometry, respectively. Fibrin-fibrinogen degradation products were measured by use of latex-agglutination. A reference range for the immunoturbidometric D-dimer concentration assay was established; sensitivity and specificity of the assay were determined at 2 cutoff concentrations (0.30 microg/ml and 0.39 microg/ml). RESULTS: Reference range for the immunoturbidometric D-dimer concentration assay was 0.08 to 0.39 microg/ml; median concentrations were significantly higher in dogs with DIC than in healthy dogs. Latex-agglutination D-dimer and serum and plasma FDP assays had similar sensitivity (85 to 100%) and specificity (90 to 100%); the immunoturbidometric assay had lower specificity (77%) at the 0.30 microg/ml cutoff and lower sensitivity (65%) at the 0.39 microg/ml cutoff. Sensitivity or specificity of the latex-agglutination D-dimer assay was not significantly improved when interpreted in series or parallel with FDP assays. CONCLUSIONS AND CLINICAL RELEVANCE: Measurement of D-dimer concentrations by latex-agglutination appears to be a sensitive and specific ancillary test for DIC in dogs. Specificity of D-dimer concentrations in dogs with systemic disease other than DIC has not been determined, therefore FDP and D-dimer assays should be performed concurrently as supportive tests for the diagnosis of DIC in dogs.  相似文献   

9.
OBJECTIVE: To evaluate a point-of-care coagulation analyzer (PCCA) in dogs with coagulopathies and healthy dogs. ANIMALS: 27 healthy and 32 diseased dogs with and without evidence of bleeding. PROCEDURE: Prothrombin time (PT), activated partial thromboplastin time (aPTT), and activated clotting time (ACT) were determined, using a PCCA and standard methods. RESULTS: Using the PCCA, mean (+/- SD) PT of citrated whole blood (CWB) from healthy dogs was 14.5+/-1.2 seconds, whereas PT of nonanticoagulated whole blood (NAWB) was 10.4+/-0.5 seconds. Activated partial thromboplastin time using CWB was 86.4+/-6.9 seconds, whereas aPTT was 71.2+/-6.7 seconds using NAWB. Reference ranges for PT and aPTT using CWB were 12.2 to 16.8 seconds and 72.5 to 100.3 seconds, respectively. Activated clotting time in NAWB was 71+/-11.8 seconds. Agreement with standard PT and aPTT methods using citrated plasma was good (overall agreement was 93% for PT and 87.5% for aPTT in CWB). Comparing CWB by the PCCA and conventional coagulation methods using citrated plasma, sensitivity and specificity were 85.7 and 95.5% for PT and 100 and 82.9% for aPTT, respectively. Overall agreement between the PCCA using NAWB and the clinical laboratory was 73% for PT and 88% for aPTT. Using NAWB for the PCCA and citrated plasma for conventional methods, sensitivity and specificity was 85.7 and 68.4% for PT and 86.7 and 88.9% for aPTT, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The PCCA detected intrinsic, extrinsic, and common pathway abnormalities in a similar fashion to clinical laboratory tests.  相似文献   

10.
Albumin concentrations are routinely measured in dogs with bromcresol green (BCG)-binding assays on automated chemistry analyzers. Several variables affect this assay, including the length of reaction time, sample type, and lack of specificity of BCG for albumin. We observed that albumin concentrations measured with BCG appeared higher in heparinized plasma samples in sick dogs. The objective of this study was to determine the effect of anticoagulant and assay procedure on BCG albumin concentrations in clinically ill dogs. We hypothesized that albumin concentrations would be overestimated in heparinized plasma compared with serum because of the combination of heparin and fibrinogen. Furthermore, we hypothesized that the overestimation would be influenced by assay parameters. Blood was collected from 32 clinically ill dogs into tubes containing heparin, citrate, or no anticoagulant. Citrate was chosen to assess the effect of fibrinogen in the absence of heparin. Albumin concentration was measured in all 3 sample types from each dog using 2 different BCG procedures on an automated chemistry analyzer. The BCG procedures (standard and modified) differed in the wavelengths used for absorbance readings (standard, 600/700; modified, 570/505) and the time point at which absorbance was measured (standard, 100 seconds; modified, 40 seconds). In addition, the modified method incorporated a sample blank. Globulin fractions, fibrinogen concentration, and indices of lipemia, hemolysis, and icterus were evaluated for their contribution to the overestimation of albumin concentration in heparinized plasma compared with serum samples. Albumin concentrations were significantly higher (P 相似文献   

11.
Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.  相似文献   

12.
Urinary assays for type I collagen metabolites provide a non invasive index of bone resorption in humans, and are widely used in the management of patients with metabolic bone diseases. The specific aims of this study were to investigate the feasibility of using commercial human assay kits for quantifying the urinary excretion of type I collagen metabolites in dogs of different ages. Urine and serum samples were collected from 35 beagle dogs in five age groups (0 to 1 years; 1 to 2 years; 2 to 3 years; 3 to 7 years; > 8 years old). Urinary concentrations of pyridinoline (Pyd), deoxypyridinoline (Dpd), and the carboxy- and amino-terminal cross-linked telopeptides of type I collagen (CTx and NTx, respectively) were measured with commercial enzyme-linked immunoassay kits. Serum concentrations of another type I collagen metabolite, the carboxy-terminal cross-linked teloptide of type I collagen (ICTP), were measured with a commercial radioimmunoassay. Dilutional studies indicated that the four urinary assays show specific cross-reactivity with canine urine. Age-related differences in urinary marker excretion were identified, with young dogs excreting the highest concentrations of Pyd, Dpd, NTx and CTx. The correlation between the individual urinary markers was excellent (r = 0.87 to 0.98), while the correlation between serum ICTP and individual urinary markers was weaker (r = 0.52 to 0.64). These results validate the usefulness of the commercial assay kits in monitoring type I collagen metabolism in dogs. Histomorphometric studies have confirmed the relationship between collagen degradation and bone resorption in humans, and similar studies are now needed in dogs.  相似文献   

13.
Bovine failure of passive transfer (FPT), defined as inadequate transfer of colostral immunoglobulins from the dam to the calf, has been associated with increased risk in neonatal mortality. Currently, radial immunodiffusion (RID) assay is considered to be the gold standard in determining FPT in serum samples from calves. There are 2 commercial RID assays routinely used for serodiagnosis of FPT in calves: VET-RID and SRID. Discrepancies between results of these RID assays were observed in the authors' laboratory. The objective of this study was to compare 2 commercial RID assays by testing a paired panel of 30 blood samples collected from newborn Holsteins at birth before, and 24 hr after, ingestion of colostrum, a commercial bovine reference serum, and a panel of different concentrations of 2 purified bovine immunoglobulin G (IgG) products. Overall, the results of this study showed a high level of discrepancy and poor agreement between the 2 RID kits. The interassay precision study revealed lower between-run coefficients of variation for the VET-RID kit compared with the SRID kit. The spiking and recovery study using purified bovine IgG products demonstrated that the VET-RID kit more closely approximates the expected concentrations of the purified bovine IgG products, whereas the SRID kit consistently overestimates the concentration of purified bovine IgG products. It was concluded that this may be due to inaccuracies in the internal standards of the SRID kit.  相似文献   

14.
利用重组N蛋白抗原建立了检测猪繁殖与呼吸综合征病毒(PRRSV)抗体的ELISA方法并组装成试剂盒,将试制的3批试剂盒分别与IDEXX生产的试剂盒及Western—blot进行了符合率试验。试验结果表明,所研制的试剂盒与Western blot的符合率达97.67%以上。对460份临床血清分别用自制的试剂盒和IDEXX公司生产的试剂盒进行检测,其中有37份不相符合,用Western blot对这37份血清进行验证,有35份血清检测结果与自制的试刺盒检测结果一致。由此表明,自行研制的试剂盒,其特异性和敏感性均能满足目前临床上该疫病的流行病学分析或免疫抗体检测。  相似文献   

15.
OBJECTIVE: To evaluate the effects of various storage conditions on one-stage prothrombin time (OSPT), activated partial thromboplastin time (APTT), and fibrinogen concentration of canine plasma collected for transfusion. SAMPLE POPULATION: Plasma from 9 dogs. PROCEDURE: Whole blood was collected from dogs by means of jugular venipuncture and centrifuged at 7,300 X g for 20 minutes at 0 C. A plasma extractor was then used to generate plasma. Aliquots of plasma were collected in segments of plastic tubing and in microcentrifuge tubes, and plasma collection bags, tubing segments, and microcentrifuge tubes were immediately frozen at -30 C. Additional tubing segments and microcentrifuge tubes were stored at 2 C. After 1 week of storage, all samples were thawed, and OSPT, APTT, and fibrinogen concentration were measured. Collection bags and microcentrifuge tubes were refrozen at -30 C, and values were measured again 30 days after blood collection. RESULTS: Values for OSPT, APTT, and fibrinogen concentration did not vary significantly with storage time, temperature, or container. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that storage for up to 30 days and at 2 C versus -30 C did not have any significant effect on hemostatic parameters of canine plasma obtained for transfusion.  相似文献   

16.
OBJECTIVE: To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. ANIMALS: 41 Toy and Miniature Poodles. PROCEDURES: After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. RESULTS: Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. CONCLUSIONS AND CLINICAL RELEVANCE: TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.  相似文献   

17.
Enzyme-linked immunosorbent assay (ELISA) test kits have been used widely to diagnose FeLV infection. Several companies have licensed such kits, but because these test kits are designed somewhat differently, a demonstration of their relative merits was needed. Differences in the sensitivity and specificity of 7 commercial test kits were determined by testing sera that induce false-negative (limiting dilution of FeLV group specific antigen, p27), and false-positive (cat anti-mouse antibody) test results. Among the panels of sera used in this study, significant differences in test kit sensitivity were not observed, but differences in specificity were identified. An interim report of these studies, supplied to the manufacturers, prompted changes in some of the kits, resulting in improved specificities. Generally, FeLV test kits are now more efficient in accurately detecting p27 in blood, serum, or plasma of cats. Nevertheless, some kits still lack specificity attributable to reagents supplied by the manufacturer.  相似文献   

18.
OBJECTIVE: To determine the effect of citrate concentration (3.2 vs 3.8%) on coagulation tests in dogs. DESIGN: Original study. ANIMALS: 30 clinically healthy dogs and 12 dogs with hereditary hemostatic disorders. PROCEDURE: Blood was collected from all dogs directly into collection tubes containing 3.2 or 3.8% buffered citrate. Prothrombin time (PT), activated partial thromboplastin time (aPTT), and fibrinogen concentration were measured by use of 3 clot-detection assay systems (2 mechanical and 1 photo-optic). Factor VIII and factor IX coagulant activities (FVIII:C and FIX:C, respectively) were determined by use of a manual tilt-tube method and a mechanical clot-detection device. RESULTS: Significant differences were not detected in median PT, fibrinogen concentration, FVIII:C, or FIX:C between 3.2 and 3.8% citrate for any assay system. A significant prolongation in aPTT for 3.2% citrate, compared with 3.8% citrate, was found in 1 mechanical system. CONCLUSIONS AND CLINICAL RELEVANCE: Citrate concentration does not significantly affect results of most coagulation assays, regardless of assay system. The aPTT was mildly influenced by the citrate concentration, although this was animal-, instrument-, and reagent-dependent. The choice of 3.2 or 3.8% citrate as an anticoagulant for coagulation tests has minimal influence on assay results in healthy dogs or dogs with hereditary hemostatic disorders.  相似文献   

19.
BACKGROUND: Blood collection tubes containing 3.2% (0.109 M) sodium citrate, instead of 3.8% (0.129 M) sodium citrate, have recently become available in the United States. These tubes are visually indistinguishable from the traditional 3.8% sodium citrate tubes, except for wording on the label. Consequently, samples for hemostatic evaluation are frequently collected in tubes containing the lower concentration of sodium citrate. HYPOTHESIS: Results of hemostasis assays are different in samples collected in 3.2% versus 3.8% sodium citrate. ANIMALS: Twenty healthy dogs. METHODS: This study aimed at determining whether results of standard coagulation tests, von Willebrand factor concentration (vWF:Ag), and platelet function with the platelet function analyzer PFA-100a were affected by the different concentrations of sodium citrate. Blood samples were collected in tubes containing either 3.2% or 3.8% sodium citrate concentrations and processed routinely for coagulation assays (one-stage prothrombin time [OSPT], activated partial thromboplastin time [aPTT], fibrinogen concentration, and platelet count), vWF:Ag, and platelet function assays with a PFA-100. RESULTS: There was no significant difference between samples collected in 3.2% versus those collected in 3.8% sodium citrate for OSPT, aPTT, fibrinogen concentration, platelet count, or vWF:Ag. The closure times with collagen/adenosine diphosphate were significantly shorter (66 +/- 8.1 versus 74.8 +/- 9.7 seconds; P < .0001) with the 3.2% than with 3.8% sodium citrate concentration, and the hematocrit was significantly higher (47.9 +/- 5.6 versus 46.0 +/- 4.7 seconds; P = .03) in samples collected in 3.2% than in those collected in 3.8% sodium citrate. CONCLUSIONS AND CLINICAL IMPORTANCE: There is no clinically relevant effect of collection of blood into 3.2% or 3.8% sodium citrate.  相似文献   

20.
BACKGROUND: Thromboelastography (TEG) is an analytical method that enables global assessment of hemostatic function in whole blood (WB) with evaluation of both plasma and cellular components of hemostasis. TEG has a largely unused potential in the diagnostic workup and monitoring of dogs with hemostatic disorders and it may be a valuable supplement to traditional coagulation parameters. OBJECTIVES: The objective of this study was to establish a clinically applicable reference interval for a TEG assay using recombinant human tissue factor (TF) as the activator on citrated WB from clinically healthy dogs and to evaluate the stability of citrated WB stored for 30 minutes (T30) and 120 minutes (T120) at room temperature (RT). Additionally, we evaluated the analytical variation in reaction time (R), clotting time (K), angle (alpha), and maximum amplitude (MA). METHODS: Blood was collected from 18 clinically healthy dogs. Duplicate TEG analyses with TF as the activator at a concentration of 1:50,000 were performed on canine citrated WB at T30 and T120. R, K, a, and MAwere analyzed. RESULTS: Mean TEG values at T30/T120 were R = 5.61/4.91 minutes, K = 4.20/3.34 minutes, alpha = 45.33/50.90 degrees , and MA = 47.96/50.19 mm. Significant differences in these values were observed after storage for T30 and T120 at RT, with a tendency towards hypercoagulability at T120. The mean coefficients of variation were low. CONCLUSIONS: Canine citrated WB can be used for TEG analysis with human recombinant TF as the activator when stored at RT for T30 or T120. At both time points, the analytical variation was low, suggesting that TEG analysis may be of value in evaluating dogs with hemostatic disorders. A fixed time point should be chosen for serial measurements.  相似文献   