Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.  相似文献   

2.
One of the most important functions of the kidney is to concentrate urine through the reabsorption of water. Urine specific gravity (USG) is used in routine tests of urine concentration and can be estimated using a refractometer. However, as the scale of Japanese refractometer is based on experimental data from healthy Japanese people, and human USG obtained by Japanese refractometers show higher values than that by refractometer produced in Europe or the U.S.A. The purpose of this study was to establish correction formulas for the USG of dogs and cats measured using Japanese refractometers. In this study, we found that Japanese refractometers overestimated USG in both dogs and cats. This study shows that the correlation formulas described in this study are useful for the accurate evaluation of USG.  相似文献   

3.
Refractometry is utilized routinely to evaluate canine urine specific gravity (USG) in veterinary clinical settings. We aimed to determine if the magnitude of interobserver reliability when assessing canine USG via refractometry could impact clinical judgment. USG was determined in 38 dogs by 3 registered veterinary technicians (RVTs) using both an optical analog refractometer and a digital refractometer. Summary statistics were reported, interobserver reliability was assessed via intraclass correlation coefficient (ICC) analysis through a 2-way mixed-effects model, and agreement between RVT pairs was compared through Bland–Altman plots. The median analog refractometer USG measurement was 1.018 (range: 1.004–1.040) and for the digital refractometer was 1.0176 (1.0035–1.0357). The analog refractometer average measure ICC was 0.995 (95% CI: 0.992, 0.997; p < 0.001). The digital refractometer average measure ICC was 0.999 (95% CI: 0.999, 1.000; p < 0.001). Strong agreement between all pairs of RVTs was seen via Bland–Altman plots for both analog and digital refractometers, with 95% CIs spanning no more than 0.002 in either the positive or negative direction for all pairings. The interobserver variability in canine USG measurements by RVTs was trivial and did not impact clinical judgment and decision-making.  相似文献   

4.
AIMS: To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers.

METHODS: To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50?g?IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated.

RESULTS: The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively.

CONCLUSIONS AND CLINICAL RELEVANCE: The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.  相似文献   

5.
The objective of this study was to evaluate the quality of the measurement of dog urine dilution/concentration by comparing osmolality with three methods of specific gravity (USG) measurement, i.e. weighing, refractometry and test strips. In unselected urine samples from 182 dogs there was a better agreement between osmolality and USG determination by refractometry (r = 0.92) than by weighing (r = 0.82) or by test strips (r = 0.27). There was an almost linear relationship between osmolality and USG: osmolality (mOsm/kg) = 36646(34318/38974) x (USGref - 1) + 25(-39/88); calculated osmolality differed from measured osmolality by more than 500 mOsm/kg in only 8 of 181 samples. There was a good agreement between USG determination by weighing and refractometry: USGref = 1.000(0.905/1.095) x USGweighing - 0.0004(-0.0019/0.0027), with a moderate bias. Only 12% of the differences between the two methods exceeded 0.010. Test strip assessment of USG was unreliable because of systematic underestimation and should not be used for dog urine. Refractometry is the best technique for routine evaluation of urine concentration/dilution when osmometry is not available.  相似文献   

6.
Background: Urine specific gravity (USG) is used clinically to estimate urine osmolality (UOsm). Although USG has been shown to have a linear correlation with UOsm in dogs, the relationship is altered when there are significant numbers of high molecular weight (MW) molecules in the urine.
Hypothesis: USG would no longer predict UOsm in dogs given intravenous hetastarch (670/0.75)(HES).
Animals: Eight healthy employee-owned adult dogs.
Methods: Prospective, controlled experimental study. USG and UOsm were measured every 30 minutes from t=0 minutes to t=360 minutes. Dogs were administered 20mL/kg of either NaCl 0.9% (control group, n=4) or HES (treatment group, n=8) IV over 1 hour starting at t=90 minutes.
Results: There was a decrease in UOsm in both groups starting at t=120 minutes and continuing for the study duration, and there was no significant difference in UOsm between treatment and control groups across all time points. There was an appropriate decrease in USG from t=120 minutes for the control group. In the treatment group, USG increased significantly at t=120 minutes ( P = .0006), t=150 minutes ( P = .0002), and t=180 minutes ( P = .0044). The largest increase in USG occurred at t=150 minutes with a mean USG of 1.070 ± 0.021 (range 1.038-1.104).
Conclusions and clinical importance: Urine specific gravity should not be used to estimate urine solute concentration in dogs following the administration of 20mL/kg of HES. In a clinical setting, the evaluation of USG following this dose of HES may lead to an overestimation of urine concentration.  相似文献   

7.

Background

Failure of transfer of passive immunity (FTPI) is the underlying predisposing risk factor for most early losses in dairy calves. Refractometers, either optical or digital, can be used to assess FTPI as a part of calf health monitoring program on dairy operations.

Objectives

To evaluate the performance of and differences between digital Brix and optical refractometers for assessing FTPI in dairy calves.

Animals

Two hundred Holstein calves from 1 to 11 days of age.

Methods

A cross‐sectional study was designed to measure serum IgG concentration by radial immunodiffusion (RID) assay, digital Brix and optical refractometers. The correlation coefficients (r) between the 2 refractometers were plotted against each other and against the measured IgG concentration from RID. The Se, Sp, and accuracy of digital Brix and optical refractometers for assessing FTPI using previously recommended cut‐offs were calculated. A receiver operating characteristic curve was created and used to identify the optimal cut‐off for this dataset.

Results

The RID IgG concentration was positively correlated with digital Brix (= 0.79) and optical (= 0.74) refractometers. The best combination of Se (85.5%), Sp (82.8%), and accuracy (83.5%) of digital Brix refractometer was at 8.3%Brix. For optical refractometer, the best combination of Se (80%), Sp (80.7%), and accuracy (80.5%) was at 5.5 g/dL.

Conclusions and Clinical Importance

Both refractometers exhibited utility in assessing FTPI in dairy calves.  相似文献   

8.
Plasma and serum protein concentrations were determined in chickens and turkeys by refractometry (with human and veterinary refractometers) and by the biuret method. Chicken and turkey serum protein values were significantly lower than respective plasma protein values according to both methods. Refractometer readings for both plasma and serum correlated closely with the results of the biuret test (r2 = 0.72 to 0.97). These findings indicate that plasma and serum protein values may be determined accurately in chickens and turkeys with a handheld refractometer.  相似文献   

9.
Blood and urine chemical values at parturition in clinically normal Holstein cows (n = 12) were compared with the same values in Holstein cows developing udder edema (n = 12). There was no statistically significant mean difference between the 2 groups for the serum and urine chemical data. Furosemide (500 mg) given IV caused a significant increase in serum calcium and sodium, urine chloride, potassium, and sodium, and fractional excretional ratio of chloride, potassium, and sodium. There was a significant mean decrease in the serum potassium, urine creatinine, osmolality, pH, and specific gravity. Hydrochlorothiazide (250 mg) given IV caused a significant mean increase in serum chloride, urine chloride, potassium, and sodium, and fractional excretion ratio of chloride, potassium, and sodium. There was a significant mean decrease in serum potassium and sodium, urine osmolality, pH, and specific gravity. Acetazolamide (500 mg) given IV caused a significant mean increase in blood urea nitrogen, serum chloride and glucose, urine sodium, and fractional excretion ratio of sodium, while causing a significant mean decrease in serum potassium, sodium, and phosphorus, and urine creatinine. Dextrose (500 g) given IV as a 50% solution caused a statistical mean increase in serum glucose, urine chloride, potassium, and sodium, and fractional excretion ratio of chloride and potassium. A statistical mean decrease occurred in the packed cell volume, blood urea nitrogen, serum calcium, potassium, sodium, and phosphorus, urine creatinine, osmolality, and pH.  相似文献   

10.
Abstract: Medical hand-held refractometers have been used in veterinary practice since their development in the 1960s. They have become ubiquitous for the measurement of protein and urine solute concentrations because of their rapidity of analysis, ease of use, and relatively low cost. Refraction of light offers advantages for the determination of solute concentrations because the measurement requires no chemical alteration of the specimen. Numerous authors have reported that the results of protein estimation by refractometry for domestic mammals correlate well with those obtained by the biuret method, although others have reported both higher and lower refractometric results compared with biuret results. Major discrepancies between biuret and refractometric results have been reported for avian samples. Some of the variation in reported results may be due to differences in design by refractometer manufacturers. Another possible source may be variation in the biuret reagent mixture and assay conditions. Refractometers also can be used to calculate serum water concentration. A table that converts index of refraction to serum water concentration can be used to convert electrolyte concentration from mmol/L of serum to mmol/L of serum water, a more accurate indicator of effective electrolyte concentration. Refractometers are especially useful for determining urine specific gravity on veterinary samples because they require relatively small sample volumes. Specific gravity continues to be the most common unit for reporting total solids concentration. Some solutes, such as acetone, may cause false increases in specific gravity by refractometry, as they increase refraction but are less dense than water.  相似文献   

11.

Background

Heat‐treatment of colostrum is a method developed to reduce calf exposure to pathogens. Infrared (IR) spectroscopy and Brix refractometers can be used for measuring colostral IgG concentration and assessing colostrum quality.

Objectives

To determine the impact of heat‐treatment on accuracy of IR spectroscopy and Brix refractometers for measuring colostral IgG concentration and assessing colostrum quality before and after heat‐treatment.

Animals

A total of 60 Holstein dairy cows on 8 commercial dairy farms.

Methods

A cross‐sectional study was designed to determine the effect of heat‐treatment at 60°C and 63°C each for 30 and 60 minutes duration on colostral IgG concentration measured by the reference radial immunodiffusion (RID) assay, IR spectroscopy, and digital and optical refractometers.

Results

Colostrum IgG concentration significantly decreased after heat‐treatment at 63°C for 30 or 60 minutes as measured by RID, but the IgG values remained unchanged when measured by IR spectroscopy and refractometers. The lowest correlation coefficient found between IR spectroscopy (= 0.70) and RID results was in colostrum heat‐treated at 63°C for 60 minutes. For digital (= 0.48) and optical (= 0.50) refractometers, the lowest correlation coefficient was at 63°C for 30 minutes when compared to RID. The accuracy of the IR spectroscopy, digital and optical Brix refractometers was decreased from 91.7 to 80%, 81.7 to 45%, and 80 to 45%, respectively, when colostrum heat‐treated at 63°C for 60 minutes.

Conclusions and Clinical Importance

Radial immunodiffusion, IR spectroscopy, and Brix refractometers exhibit utility for measuring IgG concentration when colostrum heat‐treated at 60°C but does not detect decrease IgG concentrations when heat‐treated at 63°C.  相似文献   

12.
Suggestions for interpreting qualitative urinalyses from puppies have been based on limited results obtained in the laboratory setting. Proteinuria, glucosuria, and decreased concentration of urine have been considered normal in puppies <8 weeks of age due to immature renal function. In this study, the authors reviewed 149 voided urine samples from 118 different, apparently healthy, random-source puppies. The primary finding was that mean urine specific gravity (USG) was significantly lower in 0- to 3-week-old puppies when compared to puppies 4 to 24 weeks old. Mean USG in all other age groups was >1.030. There was no difference in the frequency of positive protein or occult blood dipstick results among age groups, and there were no positive glucose, ketone, bilirubin, or urobilinogen reactions in any samples analyzed. Urine sediment results are reported for 41 samples. Epithelial cells and white blood cells were the most common sediment findings in these 41 voided samples, observed in 34 (83%) and 18 (44%) samples, respectively. Crystals were observed in 15 (37%) samples, whereas casts, bacteria, and red blood cells were observed less commonly.  相似文献   

13.
OBJECTIVE: To evaluate 3 refractometers for detection of failure of passive transfer (FPT) of immunity in calves, and assess the effect of refractometric test endpoints on sensitivity, specificity, and proportion of calves classified correctly with regard to passive transfer status. DESIGN: Prospective study. ANIMALS: 90 calves. PROCEDURE: Blood samples were obtained from calves that were < 10 days old. Serum IgG concentration was determined by use of a radial immunodiffusion assay. Accuracy of 3 refractometers in the prediction of serum IgG concentration was determined by use of standard epidemiologic methods and a linear regression model. RESULTS: At a serum protein concentration test endpoint of 5.2 g/dL, sensitivity of each refractometer was 0.89 or 0.93, and specificity ranged from 0.80 to 0.91. For all refractometers, serum protein concentration test endpoints of 5.0 or 5.2 g/dL resulted in sensitivity > 0.80, specificity > 0.80, and proportion of calves classified correctly > 0.85. Serum protein concentrations equivalent to 1,000 mg of IgG/dL of serum were 4.9, 4.8, and 5.1 g/dL for the 3 refractometers. CONCLUSIONS AND CLINICAL RELEVANCE: The refractometers, including a nontemperature-compensating instrument, performed similarly in detection of FPT. Serum protein concentration test endpoints of 5.0 and 5.2 g/dL yielded accurate results in the assessment of adequacy of passive transfer; lower or higher test endpoints misclassified larger numbers of calves.  相似文献   

14.
Studies were undertaken to determine maximal urine osmolality and urine specific gravity following water deprivation for 20 dogs with normal renal function. In addition, the reliability of body weight, skin pliability, total plasma protein concentration, and packed cell volume as indices of negative water balance was assessed. Following water deprivation for periods sufficient to induce dehydration, the mean maximal urine osmolality was 2,289 mOsm/kg. The corresponding mean maximal urine specific gravity was 1.062 and ranged from 1.050 to 1.076. The ratio of mean maximal urine osmolality to mean serum osmolality at the time of peak urine concentration was 7.3. There was no detectable difference in urine concentration indices between males and females. Changes in skin pliability and packed cell volume proved unreliable as estimates of dehydration. Weight loss and increases in total plasma protein concentration proved to be more consistent indicators of hydration status. Abnormal increases in serum urea nitrogen and serum creatinine concentrations occurred rarely, even though some dogs had water withheld for periods of up to 96 hours.  相似文献   

15.
Background: Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)≤1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. Objective: The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost‐effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Methods: Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California–Davis Veterinary Medical Teaching Hospital for samples with USG≤1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost‐effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Results: Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. Conclusions: The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost‐effective in dogs with USG≤1.013 in the absence of active urine sediment or high clinical suspicion for UTI.  相似文献   

16.
Postrace urine samples from thoroughbred horses were examined to compare osmolality and specific gravity between horses treated with furosemide and those not treated. Samples were assigned to groups in relation to reported medication (furosemide) status, race finish position, and distance of race. Urine osmolality was significantly (P <.05) lower in samples from horses treated with furosemide when compared with untreated horses. Specific gravity determinations are less precise at measuring urine osmolality at lower levels (1.01 g/ml or less). The measurement of osmolality is a superior method for determining the urine solute concentration and facilitating the regulation of furosemide.  相似文献   

17.
Oxalate nephrosis is a prevalent renal disease in koalas (Phascolarctos cinereus) of the Mount Lofty Ranges population in South Australia. The symmetric dimethylarginine (SDMA) assay is widely used in companion animals to diagnose renal disease, particularly in the early stages. This study aimed to determine: (1) reference intervals for SDMA in koalas and (2) SDMA values of koalas with oxalate nephrosis. Blood samples were collected from 41 Mount Lofty Ranges koalas euthanased on welfare grounds. Koalas were necropsied and, based on renal histopathology, were classified as unaffected (n = 22) or affected (n = 19) by oxalate nephrosis. Serum or plasma samples were analysed for creatinine, urea and SDMA and urine samples for urine specific gravity (USG). The reference interval for SDMA in unaffected koalas was 2.4–22.9 μg/dL. In koalas with oxalate nephrosis, SDMA was elevated in 74% of cases above the upper limit of the confidence interval. SDMA was elevated in three affected koalas with normal creatinine values. A positive correlation was found between SDMA and creatinine (R = 0.775, P < 0.001) and SDMA and urea (R = 0.580, P < 0.001) and a negative correlation between SDMA and USG (R = −0.495, P = 0.027). In conclusion, SDMA correlates well with other commonly used tests of renal function in koalas and should be included as part of the standard diagnostic process to increase the accuracy of oxalate nephrosis diagnosis in koalas.  相似文献   

18.
Monitoring the passive transfer of immunoglobulins from colostrums particularly in noncentrifuged samples can be useful for calf health management programs. The results of total solids refractometry from centrifuge and noncentrifuge harvested sources of serum were highly correlated (R2 = 0.95). Results from a digital and a hand-held refractometer were highly correlated (R2 = 0.96).  相似文献   

19.
Several studies in human subjects have demonstrated greater diuresis with constant rate infusion (CRI) furosemide than intermittent bolus (IB) furosemide. This study was conducted to compare the diuretic efficacy of the same total dose of IB furosemide and CRI furosemide in 6 healthy, adult Greyhound dogs in a randomized crossover design with a 2-week washout period between treatments. For IB administration, dogs received 3 mg/kg at 0 and 4 hours. For CRI administration, dogs received a 0.66 mg/kg loading dose followed by 0.66 mg/kg/h over 8 hours. The same volume of fluid was administered for both methods. Urine output was quantified hourly. Urine electrolyte concentrations, urine specific gravity (USG), packed cell volume (PCV), total protein (TP), serum electrolyte concentrations, total carbon dioxide (TCO2), serum creatinine (sCr), and blood urea nitrogen (BUN) were determined every 2 hours. Urine production and water intake were greater (P < or = 0.05) for CRI than IB. Urine sodium and calcium losses were greater (P < 0.05) and urine potassium loss was less (P = 0.03) for CRI than IB, but there was no evidence of a difference between methods for urine magnesium and chloride losses. Serum chloride concentration was less (P < 0.001), sCr concentration greater (P = 0.04). TP greater (P = 0.01), and PCV greater (P = 0.003) for CRI than IB. No differences in USG, TCO2, BUN, or serum potassium, sodium, and magnesium concentrations were detected between methods. The same total dose of CRI furosemide resulted in more diuresis, natriuresis, and calciuresis and less kaliuresis than IB furosemide in these normal Greyhound dogs over 8 hours, suggesting that furosemide is a more effective diuretic when administered by CRI than by IB.  相似文献   

20.
Cisplatin (90 mg/m2) was administered in a 5-minute bolus IV infusion to dogs at 8 AM (n = 6) or 4 PM (n = 6). Blood and urine samples were collected over a 4-hour period for statistical moment pharmacokinetic analysis. Mean urinary excretion rate of total platinum was increased, whereas mean plasma residence time of ultrafilterable platinum was decreased, in the group treated at 4 PM (PM group), compared with those treated at 8 AM (AM group). Over a 2-week postinfusion-monitoring period, both groups of dogs developed decreases in creatinine clearance, urine/serum osmolality ratio (UOsm/SOsm), specific gravity, and increase in BUN, serum creatinine concentration, urine gamma-glutamyltranspeptidase/urine creatinine ratio (UGGT/UCr), fractional excretion of magnesium, and fractional excretion of phosphate. Urine specific gravity and UOsm/SOsm were significantly decreased, whereas UGGT/UCr and BUN were significantly increased in the AM group, compared with the PM group. The time of administration had a significant effect on the pharmacokinetics of cisplatin, which resulted in significant differences in cisplatin-induced renal toxicosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号