首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
The aim of the present study was to establish which adrenal gland measurement was characterized by the least variations. To do this, we quantified the variability of seven different size measurements of the canine adrenal gland (maximal length, maximal height at the cranial and caudal poles on longitudinal and transverse images, and maximal width of the cranial and caudal poles) within observer, between observer, and between dogs based on three different measurements made by each of the three observers in six healthy Beagle dogs. The height of the caudal pole of both adrenal glands measured on longitudinal images had the lowest intra‐ and interobserver variability, while measurements of the length had the highest intra‐ and interobserver variability. Other measurements that were characterized by low intra‐ and interobserver variability were: height and width of the caudal pole on transverse images and height of the cranial pole on longitudinal images only. These results provide a basis for further study of the changes in adrenal gland size in dogs with pituitary‐dependent hyperadrenocorticism.  相似文献   

2.
OBJECTIVE: To determine the reproducibility and accuracy of computed tomographic (CT) measurements of pituitary gland dimensions in healthy dogs. ANIMALS: 35 healthy sexually intact adult dogs. PROCEDURES: 2 observers independently viewed CT images of the skull in 35 dogs twice. Pituitary gland height, width, length, and volume and pituitary gland height-to-brain area ratio (P:B ratio) were measured or calculated. Intraobserver and interobserver agreement indexes (AIs) were calculated for pituitary gland dimensions. Computed tomography was performed also on 5 phantoms, and both observers measured phantom dimensions twice. True-value AIs were calculated for the phantom study. RESULTS: The mean +/- SD interobserver AI between observer 1 and 2 for pituitary gland height and the P:B ratio was 0.90 +/- 0.07. The intraobserver AI for pituitary gland height and the P:B ratio was 0.97 +/- 0.04 for observer 1 and 0.94 +/- 0.04 for observer 2. The intra and interobserver AIs for the other dimensions were lower than those for pituitary gland height and the P:B ratio. All phantom dimensions on CT images were underestimated significantly, compared with their true values. CONCLUSIONS AND CLINICAL RELEVANCE: The intra- and interobserver AIs for pituitary gland dimension measurements on CT images were high. However, the same observer preferably should perform serial measurements. Window settings influence pituitary gland dimension measurements, and predetermined window settings are recommended to make comparisons among dogs. Pituitary gland dimension measurements made from CT images in our study underestimated the true values.  相似文献   

3.
Adrenal length and width were determined from two-dimensional ultrasound longitudinal images. In study 1, 540 measurements of adrenal glands were attempted from five healthy beagle dogs by three different observers with different levels of expertise in ultrasonography, to determine the variability of adrenal gland measurements. Of these, 484 measurements were included in the statistical analysis, since 16 measurements of the left adrenal gland and 40 for the right could not be visualised by the observer. In study 2, a single measurement of both adrenal glands was taken from each of 146 dogs by the most trained observer from study 1, and the effects of different health status (healthy dogs v dogs with non-adrenal diseases), bodyweight, age and sex were assessed. A total of 267 measurements were included in the statistical analysis. The lowest intra- and inter-day coefficient of variation values were observed for the left adrenal gland and by the most trained observer. The health status had no statistically significant effect on adrenal gland length or width, whereas age had a significant effect only for the left adrenal gland (the greater the age, the greater the width or length) and sex had a significant effect only for the right adrenal gland (the width was larger in males and the length larger in females). The bodyweight had a significant effect for the length of both adrenal glands (the greater the bodyweight, the greater the length), but not the width. The differences between sd and coefficient of variation values for the width of the left adrenal gland were not statistically significant between the three observers, whereas they were statistically significant for the right adrenal gland.  相似文献   

4.
Most prostatic diseases in dogs are associated with prostatomegaly, and transabdominal ultrasonography has become the imaging modality of choice for evaluation of the prostate gland in the dog. The aim of the present study was to assess the reproducibility, the repeatability and interobserver variations of sonographic measurements of prostate and to determine which measurement had the lowest variability. Length and height of prostate gland were measured on longitudinal views, width of the prostate gland and height of left and right lobes of the gland on transversal views. The within‐day and between‐day variabilities of the prostatic parameters were determined by performing 1350 (270 length, 270 height, 270 width, 270 height of right lobe and 270 height of left lobe) examinations on ten healthy intact beagle dogs on six different days, in a two‐week period (three days for the five dogs, three different days for the five others). Three observers with different levels of experience in ultrasonography performed the examinations. The lowest within‐day and between‐day standard deviation and coefficient of variation values were observed for the width of the prostate. The width of the gland measured on transverse frozen images seems to be the most reliable measurement for evaluating size of prostate glands in healthy dogs, although the shape, position, outline, and echogenicity of the prostate should also be assessed.  相似文献   

5.
The objective of this retrospective study was to estimate using magnetic resonance imaging the size range of the pituitary gland in cats who had no evidence of pituitary disease. The pituitary gland was measured from transverse and sagittal magnetic resonance postgadolinium T1-weighted images in 17 cats. The cats were 0.83 to 15 years of age and weighed between 2.9 and 6.5 kg. Linear pituitary measurements were performed on a dedicated workstation using electronic calipers. Mean (+/- standard deviation) pituitary gland length was 0.54 cm (+/- 0.06 cm) and mean width was 0.50 cm (+/- 0.08 cm). Mean pituitary gland height measured on sagittal images was 0.34 cm (+/- 0.05) and measured on transverse images was 0.32 cm (+/- 0.04 cm). Mean pituitary volume was 0.05 cm3 (+/- 0.01 cm3). There was no significant correlation between cat weight (kg) and pituitary volume or age and pituitary volume. The pituitary gland appearance varied on pre- and postcontrast T1-weighted images. On the precontrast images, the majority of pituitary glands had a mixed signal intensity. On postcontrast images, uniform pituitary gland enhancement was seen commonly.  相似文献   

6.
OBJECTIVE: To determine ultrasonographic characteristics of the thyroid gland in healthy small-, medium-, and large-breed dogs and evaluate the relationships of thyroid gland size and volume with body weight and body surface area (BSA). ANIMALS: 72 dogs of small (6 Toy and 6 Miniature Poodles), medium (12 Beagles), and large breeds (12 Akitas and 36 Golden Retrievers). PROCEDURE: Each dog's thyroid gland was examined ultrasonographically with a 10- to 5-MHz multifrequency linear-array transducer. Size, shape, echogenicity, and homogeneity of thyroid lobes were evaluated on longitudinal and transverse images. Thyroid lobe volume was estimated by use of the equation for an ellipsoid (pi/6 [length x height x width]). RESULTS: Thyroid lobes appeared fusiform or elliptical on longitudinal images and triangular or round to oval on transverse images. In most dogs, thyroid lobes were hyperechoic or isoechoic, compared with surrounding musculature, and had a homogeneous echogenic pattern. Mean length, width, height, and volume of thyroid lobes were significantly greater in Akitas and Golden Retrievers, compared with findings in Beagles or Poodles; mean length, width, and height were significantly greater in Beagles, compared with findings in Poodles. Total thyroid gland volume correlated with body weight (r = 0.73) and BSA (r = 0.74). CONCLUSIONS AND CLINICAL RELEVANCE: Among the dog breeds examined ultrasonographically, thyroid lobe size and volume were more variable than shape, echogenicity, and homogeneity. The correlation of thyroid gland volume with BSA suggests that size of the dog, rather than breed, should be considered when assessing thyroid glands ultrasonographically.  相似文献   

7.
OBJECTIVE: To describe the anatomic features of the pituitary gland region in horses via computed tomography (CT) and determine the accuracy of CT for estimating normal equine pituitary gland dimensions. ANIMALS: 25 adult horses with no clinical signs of pituitary disease. PROCEDURE: Transverse CT images and gross transverse tissue sections were compared in 2 horses. Contrast-enhanced CT of the pituitary gland region was performed postmortem in 23 horses with 4 slice thickness and interval settings (10-mm contiguous or overlapping slices and 4-mm contiguous or overlapping slices). Gross and CT estimates of pituitary gland dimensions were compared via ANOVA. Accuracy of CT estimates was calculated with gross pituitary gland measurements as the known value. RESULTS: Pituitary glands were located between the temporomandibular joints and had contrast enhancement. Mean gross dimensions were length, 2.11 cm; width, 2.16 cm; height, 0.98 cm; and volume, 2.66 cm3. Gross measurements and CT estimates of pituitary gland length from 10-mm contiguous and overlapping slices did not differ. Gross measurements and CT estimates of pituitary gland width from 4-mm contiguous and overlapping slices did not differ. Estimates of height and volume from all CT techniques differed from gross measurements. Accuracies for CT estimates were length, 88 to 99%; width, 81 to 92%; height, 58 to 71%; and volume, 43 to 55%. CONCLUSIONS AND CLINICAL RELEVANCE: Accuracy of estimates of pituitary gland dimension in horses varied with CT scanning technique; via CT estimates of length and width of glands were more accurate than estimates of height or volume.  相似文献   

8.
Measurement of the tibial plateau slope from lateral hind-limb radiographs is a preoperative requirement when performing tibial plateau leveling osteotomy (TPLO) for repair of the cruciate-deficient stifle in dogs. Two measurements of the tibial plateau slope in 312 stifles of 156 dogs were taken from lateral radiographs by each of three observers with varying degrees of experience in the measurement method. Intraobserver variability was +/-3.4 degrees, and interobserver variability was +/-4.8 degrees. No significant differences were identified for the intraobserver measurements; however, in evaluating interobserver variability, a significant difference was found between the inexperienced observer and the two experienced observers.  相似文献   

9.
The accepted cut‐off value for adrenal gland maximum diameter of 0.74 cm to distinguish adrenal gland enlargement in dogs regardless of body weight may not be appropriate for small to medium breed dogs. The purpose of the current retrospective study was to examine adrenal gland dimensions as a function of body weight in healthy dogs in three weight categories (< 10 kg, 10–30 kg, and > 30 kg) representing small, medium, and large breeds, respectively, to establish greater confidence in determining if adrenal gland size is abnormal. The measurements of length (sagittal plane), cranial and caudal pole thickness (sagittal and transverse planes), and caudal pole width (transverse plane) of both adrenal glands were obtained ultrasonographically in clinically healthy dogs (n = 45) with 15 dogs in each weight group. Findings support our hypothesis that adrenal gland size correlates with body weight in normal dogs, and more precise reference intervals should be created for adrenal gland size by categorizing dogs as small, medium, or large breed. The caudal pole thickness of either adrenal gland in a sagittal plane was the best dimension for evaluating adrenal gland size based on low variability, ease, and reliability in measurement.  相似文献   

10.
Sagittal and transverse ultrasonographic images of the prostate gland were obtained in 100 healthy adult intact male dogs. Prostatic length, width, and height on transverse and sagittal images as well as the presence of prostatic cysts were determined. Linear regression and correlation analysis were performed between prostatic parameters (length, width, height on sagittal and transverse images, and estimated volume) and parameters related to body size (body weight, body height, left kidney length and aortic diameter) and age of the dogs. Significant positive correlations were found between all prostatic parameters and parameters related to body size and age. Maximum predicted values for prostatic parameters for a given body weight and age were determined based on the upper limit of the 95% confidence interval of the mean predicted values. Such values should represent a useful tool for ultrasonographic evaluation of the prostate in the dog. Prostatic cysts were found in 14% of the dogs.  相似文献   

11.
12.
Objective— To compare the intra‐ and interobserver variability occurring when observers with differing experience levels measure tibial plateau angles (TPAs) with a novel digital radiographic projection program (tibial plateau leveling osteotomy [TPLO] planning program), the Kodak Picture Archiving and Communications System (PACS), and standard sized printed films (SF). Study Design— Cross‐sectional study. Sample Population— Dogs (n=36) with cranial cruciate ligament (CCL) rupture that had a TPLO. Methods— Six observers, divided into 3 equal groups based on experience level, measured TPA on 36 digitally captured radiographic images of tibiae of dogs clinically affected with CCL rupture. Each observer used 3 methods of measuring TPA and repeated the measurements 3 times with each method. The intra‐ and interobserver variability was compared using the coefficient of variation. Results— Averaged over all replications and images, there was no significant difference (P>.05) in the average variability occurring with each method for all but 1 observer. There was no effect of experience level on measurement variability; however, interobserver variability was significantly less with measurements made with the PACS and TPLO planning program compared with measurements made from SF (P<.05). Conclusions— Repeated measurements of TPA made using digital images and computer‐based measurement programs were significantly less variable between observers than those made from images printed on standard radiographic films. Clinical Relevance— Digital radiography and computer‐based measurement programs are effective for determining the TPA, allowing less variability in measurements compared with SF. The ability to manipulate the image may allow better identification of anatomic landmarks.  相似文献   

13.
Hege  Kippenes  DVM  Patrick R.  Gavin  DVM  PhD  Susan L.  Kraft  DVM  PhD  Ronald D.  Sande  DVM  MS  PhD  Russell L.  Tucker  DVM 《Veterinary radiology & ultrasound》2001,42(2):130-133
The pituitary gland was measured from transverse magnetic resonance T1-weighted images after Gadolinium administration in 96 dogs weighing from 13 to 45 kg. The measurements were done by hand with calipers. The mean (+/- standard deviation) pituitary gland height was 5.1 mm (+/-0.9 mm). The mean width was 6.4 mm (+/- 1.1 mm). The correlation coefficient between pituitary and brain measurements, between pituitary measurement and body weight, and brain measurements and body weight was 0.0 to 0.3. A hyperintense region was present on T1-weighted images in the center of the pituitary gland in 64% of the dogs. At necropsy the pituitary glands were grossly and histologically normal. No pituitary gland measurements were performed at necropsy.  相似文献   

14.
OBJECTIVE: To assess intra- and interobserver repeatability of ocular biometric measurements obtained by means of high-resolution B-mode ultrasonography in dogs. Animals-6 Beagles without ocular abnormalities. PROCEDURES: B-mode ultrasonography was performed bilaterally with a 10.5-MHz broadband compact linear array transducer. All measurements were made on 2 different occasions by 2 observers. The Bland-Altman method was used to assess agreement between measurements obtained by the 2 observers and between the 2 sets of measurements obtained by each observer. RESULTS: Intra- and interobserver repeatability was highest for larger measurements, such as depth of the eye and depth of the anterior chamber. When repeatability was examined, bias was significantly different from 0 for only a few measurements, but the percentage difference between observations was as high as 180% for some measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that most measurements of intraocular distances and structures obtained by means of high-resolution B-mode ultrasonography have acceptable intra- and interobserver repeatability. However, the percentage difference between observations can be high for smaller measurements.  相似文献   

15.
Bonnie Lynn  Boag  DVM  MSc  Matthew  Atilola  DVM  PhD  Paul  Pennock  DVM  MSc 《Veterinary radiology & ultrasound》1993,34(2):112-117
The purpose of this study was to establish sonographic baseline values for normal kidneys initu and to document sonographic changes following unilateral nephrectomy. Normal canine renal measurements were determined sonographically prior to and following unilateral nephrectomy. These included: cortical thickness (cranial, caudal, dorsal, ventral, lateral and medial), medullary measurements (cranial and caudal) and measurements of the renal silhouette (length, height and width). The latter group of measurements was obtained to determine renal volume. Normal parameters were obtained from sixteen healthy dogs prior to nephrectomy; the unilateral nephrectomy group was comprised of eight of these animals, the remaining eight dogs were part of an allo-transplant study.1 The mean sonographic value for the length of the kidney was 60.3 mm ± 6.4 (n = 26) while the widths and heights were 34.7 ± 3.8 (n = 27) and 27.8 mm ± 3.3 (n = 26) respectively. Renal cortical measurements were found to be smallest dorsally and ventrally on sagittal and transverse sonograms. The largest volumes were the cranial pole on sagittal scans and the lateral pole on the transverse scans. Pearson correlation coefficient for volume resulted in r values of 0.88, 0.78 and 0.72 for length, height and width (n = 25, dif = 24) respectively.  相似文献   

16.
The aims of this study were to determine the size of the medial retropharyngeal lymph nodes in apparently healthy dogs using ultrasonography and to investigate relationships between body weight (1.8-59 kg), age (1.0-15 years), and medial retropharyngeal lymph node sizes (width, height, and length). The sample population consisted of 100 apparently healthy, volunteered, adult dogs. The data were normally distributed, thus mean, SD, and Pearson's correlation were used. Repeatability of ultrasound measures was assessed as the percentage of differences between duplicate measures that were within 2 SDs of the differences: all measures were at least 93% repeatable (differences typically were < or = 0.25 cm and always < 1 cm). No difference between sexes was observed. The medial retropharyngeal lymph node increased in size with increased body weight (r = 0.46 to 0.59) and decreased in size with increased age (r = -0.30 to -0.50). Although statistically significant, the actual variation is not likely clinically important due to the small range of sizes, measurement error, and various combinations of age and body weight. Therefore, regardless of body weight or age, the average width is 1.0 cm, height is 0.5 cm, and length is 2.5 cm and maximum width is 2 cm, height is 1 cm, and length is 5 cm. Based on the maximal difference between duplicate measures (with some exception), any change > or = 0.4 cm with width or height, or > or = 1.0 cm in length, in a follow up measurement probably represents a true biological change rather than measurement error.  相似文献   

17.
Objectives : To describe the computed tomography (CT) features of the prostate gland and determine prostate size using CT in entire male dogs. Methods : The prostate gland was evaluated in 35 dogs. Morphological features including homogeneity, delineation, shape and intraprostatic differentiation were assessed. Height, length, width, area, volume and attenuation values of the prostate gland were measured. Ratios of prostatic height (rH), length and width to the sixth lumbar vertebral body length were calculated. Relationships of prostatic dimensions with body weight and age were evaluated. Results : The prostate gland was homogeneous in 29 dogs on non‐contrast images and 18 of 24 dogs on postcontrast images. Transverse images revealed a semi‐oval prostate gland in 29 dogs and irregularly shaped prostate gland in 6 dogs. A prominent median septum was observed in postcontrast images. Significant positive correlations were found between body weight and age and all prostatic dimensions except between age and rH. The mean ±sd values for attenuation were 59·3 ±9·1 and 121·3 ±22·7 HU in non‐contrast and postcontrast image, respectively. Clinical Significance : CT can be useful for evaluating morphological features of the prostate gland. Prostatic length or width is a better measure than height for computed tomographic estimation of prostate size.  相似文献   

18.
Out of 400 Irish wolfhounds cardiologically examined, echocardiographic measurements of 262 normal dogs were analyzed to obtain reference values for the breed. Based on regression analysis, several echocardiographic parameters showed significant linear correlation with body weight and with age, but coefficients of determination were low. Therefore, due to a high individual variability of echocardiographic measurements in adult Irish wolfhounds, the predictive value of body weight for echocardiographic measurements was clinically not relevant. Sex had no influence on echocardiographic values. For the estimation of myocardial function, end-systolic volume index (ESVI) (mean, 29.0 ml/m2 +/- standard deviation [SD], 5.9 ml/m2) was determined for the group of 262 normal dogs.  相似文献   

19.
OBJECTIVE: To describe an anal approach for excision of primary rectal tumors in dogs and to report outcome. STUDY DESIGN: Retrospective study. ANIMALS: Dogs (n=23) with primary rectal tumors. METHODS: Review of medical records (1990-2000) of dogs with primary rectal neoplasia excised surgically using an anal approach with rectal prolapse. With dogs anesthetized, the rectum was prolapsed, stabilized with stay sutures during tumor excision with 1 cm margins to the level of the muscularis, then the rectal mucosa was sutured. RESULTS: Each dog had only 1 tumor type (adenocarcinoma [8], solitary polyp [5], carcinoma [4], plasmacytoma [2], adenoma [1], leiomyoma [1], mucinous carcinoma [1], and papilloma [1]). Mean tumor volume was 3.1 cm(3) (range 0.1-37.7 cm(3)). Postoperative complications (rectal bleeding [5], tenesmus [4]) were mild and resolved within 7 days after surgery; another dog had partial mucosal dehiscence identified at 6 days. The primary tumor was incompletely excised in 1 dog (4.3%), and local recurrence occurred 16 and 24 months after surgery in 2 dogs. Outcome beyond the immediate postoperative period was known for 18 dogs, including 2 dogs still alive. Mean postoperative disease-free interval for these 18 dogs was 36.8 months (range 5-84 months). CONCLUSION: Surgical excision of tumors of the caudal rectum can be accomplished through the anus after rectal prolapse. CLINICAL RELEVANCE: An anal approach facilitated by rectal prolapse should be considered as a viable option for the surgical treatment of selected cases of tumors of the caudal aspect of the rectum in dogs.  相似文献   

20.
We conducted a retrospective study in presumed normal dogs to determine the adrenal gland attenuation and volume values. Multidetector computer tomography (MDCT 16) analysis of the gland was carried out in 48 adult dogs without evidence of adrenal gland disease that underwent CT examination for acute spinal injuries. The mean nonenhanced attenuation value +/- SD of the left adrenal gland was 36.0 +/- 5.3 HU (range: 22.0-42.0 HU). The mean nonenhanced attenuation value +/- SD of the right gland was 34.3 +/- 7.0 HU (range: 20.4-48.6HU). The mean enhanced attenuation value +/- SD were: left gland 101.5 +/- 10.6HU (range: 86.8-128.0 HU), and right gland 97.4 +/- 12.4 HU (range: 58.9-123.6 HU). The mean CT volume +/- SD were: left gland was 0.60 cm3 (range: 0.20-0.95; SD 0.17), and right gland (0.55cm3, range: 0.22-1.01; SD 0.19). Attenuation values and volume data were related to age, weight, and gender, using ANOVA. There was no statistically significant difference between the left and right side or in adrenal measurements, because of body weight class effects. The animal effect was the most important source of variation for all adrenal measurements. Based on our study, CT is an effective method for assessing adrenal characteristics in the dog. Normative CT data are provided to allow estimation of normal adrenal gland size and volume.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号