首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Specialized training is required to obtain adequate cytology smears by needle aspiration biopsy. An educational method that would provide opportunity for numerous trainees to acquire needle aspiration biopsy and cytodiagnostic skills, and which would not result in the interruption of teaching hospital patient care nor result in the use or sacrifice of animals from laboratory animal resources was sought. An aspiration biopsy cytology teaching aid was developed by placing portions of fresh organ tissue from routine submissions to the necropsy laboratory into a specimen container partially filled with chilled normal saline solution. Specimens were stored immersed in saline at 4 degrees C for up to 48 hours. Prior to the cytopathology teaching laboratory period, the specimen container was removed from storage and covered with a latex diaphragm. Instructors responsible for teaching cytodiagnostic techniques used this ex vivo aspiration biopsy cytology device for instruction of fine needle aspiration biopsy, specimen processing, and microscopy. In the teaching laboratory, puncture of the diaphragm and aspiration of a tissue sample with hypodermic needle and syringe was instructed to, and practiced by, numerous trainees simultaneously using clinical operative technique without the need for live animals. Trainees prepared and stained cytology smears as well as evaluated and interpreted specimens in a single, realistic exercise. Such training experience may improve ability of trainees to procure diagnostic-quality biopsy specimens for cytodiagnosis of lesions from clinic patients.  相似文献   

2.
OBJECTIVE: To determine safety of lung biopsy in healthy cattle and compare 3 biopsy instruments for suitability of use. DESIGN: Prospective study. ANIMALS: 60 healthy cows. PROCEDURE: Bilateral lung biopsy through the ninth intercostal space was attempted in all cows. The procedure was performed with cows standing and restrained by an assistant. To study the short-term effects of lung biopsy, 50 cows were slaughtered 1 day after the procedure and examined. To study the long-term effects of lung biopsy, the remaining 10 cows were examined daily for 10 days and then slaughtered. Three biopsy instruments--the Autovac biopsy cannula, the Tru-Cut needle, and the Bard Biopty-System--were evaluated. RESULTS: 2 cows collapsed momentarily during the procedure but recovered quickly. The remaining cows did not develop adverse effects, and general attitude and condition were not affected. Postmortem examination of the 50 cows slaughtered 1 day after the procedure revealed lesions < or = 5.0 mm long and with a surface area < or = 4.0 mm2 at 108 of 154 (71%) biopsy sites involving the pulmonary pleura. Biopsy specimens were obtained during 48 of 50 (96%) procedures in which the Tru-Cut needle was used, during 38 of 39 (97%) procedures in which the Bard Biopty-System was used, and during only 1 of 11 biopsy procedures in which the Autovac cannula was used. At postmortem examination of the 10 cows slaughtered 10 days after the procedure, lesions were seen as small scars; adhesions were not observed. CONCLUSIONS AND CLINICAL RELEVANCE: Percutaneous lung biopsy is a safe procedure in healthy cows.  相似文献   

3.
Three healthy cats were subjected to percutaneous renal biopsy of the left kidney on three occasions at monthly intervals. Three other cats were subjected to three consecutive biopsy attempts on one occasion using the left kidney. Thereafter the six cats were monitored clinically and by means of laboratory analyses of blood and urine until euthanasia four weeks after the last biopsy. Cautious insertion of the biopsy needle in an attempt to avoid over penetration of the kidney resulted in failure to obtain renal tissue on six occasions but in all 12 specimens which did contain renal tissue, glomeruli were present. Major blood vessels were present in two biopsy specimens. At necropsy, radiographic and histological studies demonstrated renal parenchymal and vascular changes in the biopsied kidneys which were similar to but less severe than those produced by a single biopsy attempt. This confirmed that avoidance of damage to major renal vessels is important and suggested that, with care, repeated biopsies need be no more harmful to the kidney than a single biopsy.  相似文献   

4.
BACKGROUND: Liver biopsy is useful in the diagnosis of liver disease in horses. However, bleeding is the major complication. Liver dysfunction can result in abnormalities in coagulation, although there is no definitive association between risk of hemorrhage after biopsy and coagulopathy in humans. Frequency of coagulopathies in horses with liver disease and the nature and frequency of complications after liver biopsy are not reported. HYPOTHESIS/OBJECTIVES: To determine whether there is an association between coagulopathy and hemorrhage after liver biopsy in horses. ANIMALS: Horses with suspected liver disease from which a liver biopsy had been obtained. METHODS: Retrospective study. Variables indicative of coagulation were recorded. The frequency and nature of complications after biopsy were assessed using clinical and hematologic data. The association between abnormal coagulation variables and complications was assessed. RESULTS: Seventy biopsies were obtained from 66 horses. At least 1 coagulation profile abnormality was identified in 58% of the 43 horses with histopathologically confirmed liver disease. Complications were observed in 4/32 monitored horses (33 biopsies). Three horses had a decrease in the packed cell volume suggestive of subclinical bleeding, and 1 horse developed a diaphragmatic hematoma. There was no association between coagulation profile abnormality and complications. CONCLUSION AND CLINICAL IMPORTANCE: Abnormalities of coagulation are common in horses with liver disease. Liver biopsy appears to be a safe procedure in the horse. An abnormal coagulation profile is not clearly associated with an increased risk of complications after biopsy.  相似文献   

5.
Forty-eight fine-needle aspiration biopsy specimens of intrathoracic lesions were obtained with a Westcott needle by localizing needle placement using TV-monitored, image-amplified fluoroscopy and by detecting changes in tactile sensation. Thiryt-five lesions were pulmonary in origin and 13 were within the mediastinum. Most biospy specimens were obtained with the patients sedated, however, general anesthesia was used in one patient to prevent movement that could have resulted in puncture of a critical structure. The only clinical and radiographic complication from this procedure was pneumothorax, occurring in eight dogs and resulting in one death. Definitive diagnoses were made from tissue obtained from 37 of the 48 lesions sampled for a sensitivity rate of 77.1%. Fine-needle aspiration biopsy was found to be a simple, safe, and accurate diagnostic technique.  相似文献   

6.
Currently, a histological diagnosis of highly vascularized canine (c) thyroid carcinoma (TC) is primarily obtained following excisional biopsy (EB) through thyroidectomy. Non-EBs are contraindicated in unresectable invasive cTCs due to their highly vascularized nature, which subsequently, lack histological diagnosis. We hypothesised ultrasound-guided core needle biopsy (UGCNB) to be a safe biopsy technique to obtain an accurate histological diagnosis in unresectable TCs. Nine client-owned dogs with suspected naturally occurring TC, presented for surgical excision, were included. First, a UGCNB was taken from the cervical tumour, followed by EB. Haemorrhage following UGCNB was evaluated preoperatively and once the tumour was surgically exposed by visual inspection and ultrasonography. Histological analysis, including cell organisation, tumour capsular and vascular invasion, and immunohistochemistry were performed and compared between both biopsy specimens (i.e., UGCNB and EB) of the same dog. Pre- and peroperative visual inspection revealed minor, localised haemorrhage, subsequent to the UGCNB, in 7/9 dogs. Histology of the EBs confirmed TC in 8/9 dogs and was inconclusive in 1/9 dogs. Histology of the UGCNBs revealed neoplastic thyroid tissue in 7/9 UGCNBs and was inconclusive in 1/9 UGCNBs. The remaining UGCNB contained no mass related tissue and was, therefore, excluded. Histological parameters (i.e., cell organisation, tumour capsular and vascular invasion) were not concordant between 6/8 included UGCNBs and their respective EB. Immunolabelling for thyroglobulin and calcitonin was concordant between all eight included UGCNBs and their respective EB. The remaining evaluated immunohistochemical markers (i.e., cyclooxygenase-2 [COX-2], P-glycoprotein and vascular endothelial growth factor [VEGF]) were concordant between the included UGCNBs and the EBs in 6/8 dogs. To conclude, UGCNBs can be safely obtained in suspected cTCs and enable a reliable diagnosis of the thyroid origin, thyroid cell origin and potential therapeutic markers such as COX-2, P-glycoprotein and VEGF. Subsequently, UGCNB enables clinicians to establish an individually tailored treatment plan in dogs with unresectable TC.  相似文献   

7.
The purpose of this study was to develop a percutaneous lung biopsy technique to be used on steers in a commercial feedlot setting. Thirty-four crossbred steer and heifer calves from a commercial feedlot in southern Alberta were used in this study. The calves originated from the auction market and all were chronically affected with bovine respiratory disease (BRD). A technique was developed to obtain a lung sample from the right cranioventral lung lobe, intercostal space (ICS) 2, using a manual or an automatic biopsy instrument with a 14- or 12-gauge (ga) biopsy needle. Overall, lung parenchyma was successfully harvested in 55.9% of experimental animals and in 55.0% of lung biopsy trials. Compared with postmortem diagnosis, the biopsy resulted in the same pathologic diagnosis for 75% of biopsy samples when evaluated using standardized criteria by the same veterinary pathologist. The success rate was 61.5% and 42.9% in a hospital or field setting, respectively. With an automatic instrument, lung was recovered from 57.9% and 37.5% of samples obtained using a 12- or 14-ga biopsy needle, respectively. One experimental animal or 2.9% of the total had fatal complications from the procedure. In a commercial feedlot setting, the procedure took 20 min for each animal. Percutaneous lung biopsy of the right cranioventral lung lobe may be a viable technique when used on feedlot steers affected with chronic pneumonia. These findings suggest that using an automatic instrument with either a 14- or 12-ga biopsy needle may yield lung samples that are suitable for histopathological evaluation. However, this technique needs to be further evaluated in a field setting.  相似文献   

8.
OBJECTIVE: To develop a technique for sternal bone biopsy in standing horses. STUDY DESIGN: Experimental study. ANIMALS: Five adult horses. METHODS: Horses were restrained in a standing stocks and sedated. The sternal biopsy site, identified by ultrasonographic examination, was clipped and prepared for aseptic surgery and infiltrated with local anesthetic. An electric bone biopsy drill (Osteocore; Institut Straumann AG, CH-4437, Waldenburg, Switzerland)), which yielded 4-mm-diameter bone specimens, was used to obtain sternal biopsies through a small skin incision. Sections (7 microm) of the bone specimens were stained with toluidine blue and Goldner's green trichrome and observed microscopically to determine suitability for histological and histomorphometric evaluation. RESULTS: The most suitable sternal biopsy site was at the 4th or 5th sternebra. The surgical procedure was easy to perform and well tolerated by the horses, and adequate samples were obtained on the first attempt. The only complications were incisional edema in all horses and wound drainage in 1 horse. CONCLUSIONS: Sternal bone biopsy may be successfully performed in standing horses, and the technique described in this report yields architecturally intact bone specimens. CLINICAL RELEVANCE: The sternum is an accessible site for cancellous bone biopsy specimens in standing horses.  相似文献   

9.
Real-time ultrasonography was used to assist percutaneous renal biopsies in seven normal horses. Ultrasound (US) guidance and blind biopsy following US localization were compared. Ten biopsies (seven right kidney and three left kidney) were performed. A transverse approach to the lateral border of the right kidney through the 17th intercostal space was favored, with the needle angle being approximately perpendicular to the body wall. Both biopsy techniques were effective, but blind biopsy following US localization was favored as it was easily performed by one operator without the need for specialized biopsy equipment. The spleen had a variable location and its penetration with the biopsy needle was necessary to obtain two left kidney biopsies. Macroscopic and microscopic hematuria was observed postbiopsy in one and four horses, respectively, out of six horses examined. Perirenal hemorrhage was a prominent finding on necropsy in five of six horses euthanized.  相似文献   

10.
Lung biopsy in cattle for the diagnosis of lung diseases is rarely used or described. The clinical effects and the gross findings in lung and pleura after ultrasonic-guided percutaneous lung biopsy in the upright animal of healthy cattle were reported previously (Braun et al., 1999). This report describes the yield of attained lung tissue and the local tissue reaction in 60 healthy adult cows slaughtered 24 h (50 animals) and 10 days (10 animals) after invasion. The yield of lung tissue in the biopsies was high (85.5%) in 90 histologically examined biopsy specimens and judged 'good to excellent'. The local tissue reaction and the extent of haemorrhage in the lung parenchyma, both 24 h and 10 days after the biopsy, were minimal. In the latter group, the scar tissue had approximately the same dimensions as the tissue cylinders punched 10 days before. There were no local adhesions between the pleural surfaces. Previously published data concerning clinical reactions and complications, macroscopically examined local tissue bleeding and the histologically evaluated minimal local inflammatory reaction, following lung biopsy of cattle, indicate that this procedure is safe and satisfactory for sampling of accurate lung material. The results of this study concur and indicate that local complications in the animal were minimal to absent.  相似文献   

11.
We examined 18 horses with clinical signs of chronic obstructive pulmonary disease (COPD) using physical examination, cytological and bacteriological evaluation of bronchoalveolar fluid, and percutaneous lung biopsy. In 16 cases, histological examination of lung tissue confirmed the diagnosis of COPD. Two horses were excluded: one had uncomplicated bacterial pneumonia and in the other a satisfactory lung biopsy could not be obtained. In horses with COPD, the most common historical complaint was coughing, which was reported in 88%. The most frequently detected abnormal finding on physical examination was abnormal lung sounds; these were detected in 69% of horses at rest and in 88% of horses breathing deeply into a bag. A novel finding was that 29% of horses had lung sounds that were quieter than would be expected for the degree of respiratory effort. Horses with COPD had increased percentages of neutrophils and decreased percentages of lymphocytes and macrophages in their bronchoalveolar lavage fluid. Bronchiolar neutrophil infiltration and peribronchiolar mast cell accumulation in lung biopsy tissue had the highest correlation with clinical condition. The severity of pathological changes in biopsies of lung did not predict whether the horse would die in the two to four year follow-up period. Horses that died in the follow-up period were more severely affected clinically at initial presentation than horses that were alive at the end of the follow-up period.  相似文献   

12.
This study was performed to determine if a peripheral sample of lung from the site where biopsy is conducted is representative of the rest of the lung and to investigate the relationship between airway inflammation and intraepithelial mucous production in the peripheral airways. Lung parenchyma samples were collected from five different regions of the lung in five control and five heaves-affected horses. Horse groups were defined by clinical response to stabling. Tissue sections were used for semi-quantitative scoring of lesions, to count the number of airways, to quantify the amount of stored mucosubstances (Vs) within the epithelium, and to count the number of epithelial cells in terminal airways. No significant differences were found between lung regions or between groups of horses. Lack of regional differences in airway structures means that a biopsy sample can be used for diagnosis and investigation of diffusely distributed diseases. Airway inflammation was correlated with mucous cell metaplasia and Vs. Therefore, in horses, mucus accumulation is partly caused by increased number of mucous cells and is associated with airway inflammation. Therapy targeted to reduce airway inflammation will help reduce the excessive mucous accumulation in horses.  相似文献   

13.
OBJECTIVE: To determine whether testicular needle biopsy is detrimental to testicular function in clinically normal bulls. DESIGN: Prospective study. ANIMALS: 6 mixed-breed mature bulls. PROCEDURE: A randomly selected testicle from each bull was biopsied with a 14-gauge needle biopsy instrument. Bulls were then evaluated over a 90-day period for changes in scrotal temperature and thermal patterns, ultrasonographic appearance, and quality of spermatozoa. At the end of the 90-day study, bulls were castrated, and testicles were examined grossly and histologically. RESULTS: Changes were detected in scrotal temperatures and thermal patterns and in the breeding soundness examination results during the first 2 weeks of the study. However, there were no long-term changes in semen quality over the course of the experiment. Hyperechoic areas were detected on ultrasonographic examination and corresponded to the areas of penetration by the biopsy instrument. Microscopic lesions that were indicative of testicular dysfunction were not found. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicate that testicular biopsy is a safe procedure in bulls. Testicular biopsy could possibly be used to further examine bulls that have less than satisfactory results for breeding soundness examinations.  相似文献   

14.
OBJECTIVE: To compare morphologic diagnoses determined from needle biopsy specimens obtained from the livers of dogs and cats with morphologic diagnoses determined from wedge biopsy specimens. DESIGN: Prospective study. ANIMALS: 124 dogs and cats. PROCEDURE: 2 needle biopsy specimens were obtained from each animal; wedge biopsy specimens were obtained from the same liver lobe during laparotomy or postmortem examination. Histologic features were scored independently by 3 individuals; a morphologic diagnosis was rendered after histologic features were scored. Cases were included only if at least 2 of the 3 examiners agreed on the morphologic diagnosis; the definitive diagnosis was considered to be the morphologic diagnosis rendered for the wedge biopsy specimen. Physical characteristics (length, width, surface area, degree of fragmentation, and number of portal triads for needle biopsy specimens and surface area for wedge biopsy specimens) were determined. RESULTS: Definitive diagnoses included hepatic necrosis (n = 10), cholangitis-cholangiohepatitis (13), chronic hepatitis-cirrhosis (12), canine vacuolar hepatopathy (11), portosystemic vascular anomaly-microvascular dysplasia (17), neoplasia (10), miscellaneous hepatic disorders (18), and no hepatic disease (33). For individual examiners, the morphologic diagnosis assigned to needle biopsy specimens agreed with the morphologic diagnosis assigned to wedge biopsy specimens for 56 and 67% of the specimens. All 3 examiners agreed on the morphologic diagnosis assigned to needle and wedge biopsy specimens for 44 and 65% of the specimens, respectively. Morphologic diagnoses assigned to needle biopsy specimens concurred with the definitive diagnosis for 59 of 124 (48%) animals. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that needle biopsy specimens of the liver from dogs and cats must be interpreted with caution.  相似文献   

15.
OBJECTIVE: To evaluate leukotriene (LT) biosynthetic capacity in lung tissue from healthy horses and horses with recurrent airway obstruction (RAO). SAMPLE POPULATION: Lung parenchyma and airway specimens from 8 RAO-affected and 5 healthy horses. PROCEDURE: Horses were stabled for > or = 72 hours. Blood was drawn before euthanasia, after which lung specimens were collected. Tissue strips from small airways and parenchyma were incubated in organ baths with the precursor LTA4 or stimulated with calcium ionophore A23187 or the tripeptide N-formyl-Met-Leu-Phe (fMLP), with or without exogenous arachidonic acid, in the presence of isolated blood neutrophils. RESULTS: Stabling induced typical clinical signs of airway obstruction in RAO-affected horses but not control horses. When lung parenchyma or airway specimens from both groups of horses were incubated with calcium ionophore, with or without arachidonic acid, they did not form LT. In contrast, addition of LTA4 to both tissues resulted in conversion to LTB4, although concentrations of LTC4 were negligible in airways and parenchymal strips from healthy and RAO-affected horses. Incubation of airway and parenchymal strips with suspensions of autologous neutrophils did not influence formation of LT stimulated by calcium ionophore or fMLP, with or without exogenous arachidonic acid. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that lung parenchyma and airway tissues themselves are not of substantial importance for LT formation in the lungs, although these tissues possessed some LTA4 hydrolase activity, enabling LTB4 formation. It may be speculated that LTB4 originates primarily from neutrophils and may play a role in the inflammatory events of RAO.  相似文献   

16.
OBJECTIVE: To assess a technique for laparoscopic collection of serial full-thickness small intestinal biopsy specimens in horses. ANIMALS:13 healthy adult horses. PROCEDURES: In the ex vivo portion of the study, sections of duodenum and jejunum obtained from 6 horses immediately after euthanasia were divided into 3 segments. Each segment was randomly assigned to the control group, the double-layer hand-sewn closure group, or the endoscopic linear stapler (ELS) group. Bursting strength and bursting wall tension were measured and compared among groups; luminal diameter reduction at the biopsy site was compared between the biopsy groups. In the in vivo portion of the study, serial full-thickness small intestinal biopsy specimens were laparoscopically collected with an ELS from the descending duodenum and distal portion of the jejunum at monthly intervals in 7 sedated, standing horses. Biopsy specimens were evaluated for suitability for histologic examination. RESULTS: Mean bursting strength and bursting wall tension were significantly lower in the ELS group than in the hand-sewn and control groups in both the duodenal and jejunal segments. Use of the hand-sewn closure technique at the biopsy site reduced luminal diameter significantly more than use of the stapling technique. In the in vivo part of the study, all 52 biopsy specimens collected during 26 laparoscopic procedures were suitable for histologic examination and no clinically important perioperative complications developed. CONCLUSIONS AND CLINICAL RELEVANCE: Laparoscopic collection of serial full-thickness small intestinal biopsy specimens with a 45-mm ELS may be an effective and safe technique for use in healthy adult experimental horses.  相似文献   

17.
A group of racehorses in training was examined on several occasions with a fibreoptic endoscope and monitored for viral infection. Only equine herpes virus-2 (EHV-2) infection was detected. Pharyngeal lymphoid hyperplasia (PLH) was present in all horses and decreased in severity with age. There was no association between PLH severity and antibody titres to EHV-1, or with the isolation of EHV-2. Finishing position in races was not affected by PLH severity. Exercise induced pulmonary haemorrhage (EIPH) was evident on 23 out of 49 (47 per cent) examinations after maximal speed training exercise. Eighteen out of 19 (95 per cent) horses examined on at least two occasions had EIPH but its occurrence was not predictable. Observable mucoid or mucopurulent exudate was present in the trachea in 60 out of 118 (50 per cent) examinations and the amount seen was increased following exercise.  相似文献   

18.
Skin biopsies are a viable diagnostic tool in avian dermatology, however, the thinness of avian skin makes it difficult to prevent rolling and contraction of skin biopsy specimens during collection and fixation. The difficulty orienting such rolled samples during processing ultimately interferes with the establishment of a histopathological diagnosis. We describe a modified skin biopsy procedure for obtaining avian skin biopsy specimens. In this technique nontranslucent self-adhesive tape (Scotch tape) was attached to skin biopsy sites before obtaining skin biopsies using a standard skin biopsy punch instrument. A total of 23 skin biopsy specimens were obtained: 15 from nonfeathered skin of 12 normal Hispaniolan parrots, 3 from feathered skin of 2 normal birds and 5 from feathered skin of 3 psittacines presented for pathologic feather-picking. All 23 skin specimens consistently adhered to the tape during the biopsy procedure. The specimens were fixed in 10% neutral phosphate-buffered formalin. During processing, no curling or rolling of specimens occurred, and all specimens could be easily orientated for correct trimming and subsequent histopathological evaluation. The tape technique did not produce any appreciable artefacts. Remnants of the tape were microscopically evident above the stratum corneum assuring that none of the stratum corneum was lost during processing. Obtaining avian skin biopsy specimens using this modified tape technique is easy and ensures flat fixation of the skin biopsy specimens, which later allows trimming at right angles, and through the longitudinal diameter of feather follicles for accurate histopathologic evaluation.  相似文献   

19.
OBJECTIVE: To correlate clinical score, intrapleural pressure, cytologic findings of bronchoalveolar lavage fluid (BALF), and histologic lesions of pulmonary tissue in horses affected with summer pasture-associated obstructive pulmonary disease (SPAOPD). ANIMALS: 8 adult horses affected with SPAOPD and 6 adult horses without evidence of respiratory tract disease. PROCEDURE: Clinical score, change in intrapleural pressure (deltaPpl) during tidal breathing, results of cytologic examination and bacteriologic culture of BALF, and results of histologic examination of pulmonary parenchyma were evaluated. RESULTS: Clinical scores for SPAOPD-affected horses (median, 5.75; range, 4.0 to 7.5) were significantly greater, compared with clinically normal horses (median, 2.0; range, 2.0 to 3.0). Cytologic examination of BALF from SPAOPD-affected horses revealed predominantly nondegenerate neutrophils. Histologic lesions were identified throughout pulmonary tissue and included severe accumulation of mucus and neutrophils within the small airways, metaplasia of bronchiolar goblet cells, and mild peribronchial infiltrate. Histologic examination of specimens collected via percutaneous biopsy was predictive of disease and corresponded to findings at postmortem examination. Clinical score and deltaPpl were highly correlated with mucus accumulation in the airways of affected horses. Peribronchial inflammatory infiltrate correlated with percentage of neutrophils in BALF of affected horses. CONCLUSIONS AND CLINICAL RELEVANCE: Clinical scoring and deltaPpl provided valid estimates of disease severity. Findings from cytologic examination of BALF of SPAOPD-affected horses varied, although, in most instances, it was diagnostically useful. Severe mucus accumulation in the airways was the most remarkable histopathologic finding in SPAOPD-affected horses. Examination of biopsy specimens collected from pulmonary parenchyma was consistently useful in diagnosing SPAOPD.  相似文献   

20.
A disposable biopsy needle was modified to reduce the length of the obturator tip and specimen notch. The modified needle was then used to take renal biopsy specimens at four sites from each kidney in four cats. Twenty-nine samples of renal tissue were obtained and the average numbers of glomeruli per specimen length compared favourably with similar studies using the standard needle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号