首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
REASONS FOR PERFORMING STUDY: It has long been recognised that the production of abnormal respiratory sounds by horses during exercise is frequently associated with upper airway obstructions. Respiratory acoustic measurements have shown promise in investigation of upper airway disorders in man and, more recently, in horses with experimentally-induced obstructions. OBJECTIVES: To evaluate sounds from exercising horses with naturally occurring dynamic obstructions of the upper respiratory tract and to compare these with those from normal horses in order to determine whether different obstructions produce characteristic spectral patterns. METHODS: The audio signal, airflow and videoendoscopic images were recorded simultaneously during an incremental exercise test on a high-speed treadmill. RESULTS: Spectral analysis of the audio signal showed marked differences between control and clinically afflicted horses. Dorsal displacement of the soft palate was characterised by a narrow low frequency (20-80 Hz) peak during expiration. Horses with dynamic laryngeal collapse produced inspiratory sounds characterised by a broad band high frequency spectral component in the range 1.1-2.7 kHz. CONCLUSIONS AND POTENTIAL RELEVANCE: Spectral analysis of respiratory sounds in horses has potential as a diagnostic technique for field use especially when facilities for high-speed treadmill assessment are not practicable.  相似文献   

2.
The objective of this study was to build audiograms from thresholds of brainstem tone-evoked potentials in dogs and to evaluate age-related change of the audiogram in puppies. Results were obtained from 9 Beagle puppies 10-47 days of age. Vertex to mastoid brainstem auditory-evoked potentials in response to 5.1-millisecond Hanning-gated sine waves with frequencies octave-spaced from 0.5 to 32 kHz were recorded. Three dogs were examined at 10, 13, 19, 25, and 45 days. Four other dogs were examined at 16 days. Data from 7 dogs between 42 and 47 days of age were pooled to obtain audiogram reference values in 1.5-month-old puppies. The best auditory threshold lowered from above 60 dB sound pressure level (SPL) to values close to 0 dB SPL between 13 and 25 days of age and then stabilized. The audible frequency range widened, including 32 kHz in all tested dogs from the 19th day. In the 7 1.5-month-old puppies, the mean auditory threshold decreased by 11 dB per octave from 0.5 to 2 kHz. The auditory threshold was lowest and held the same value from 2 to 8 kHz. The mean auditory threshold increased by 20 dB per octave from 8 to 32 kHz. Near threshold, click-evoked potentials test only a small part of the audible frequency range in dogs. Use of tone-evoked potentials may become a powerful tool in investigating dogs with possible partial hearing loss, including during the auditory system maturation period.  相似文献   

3.
This study evaluates the effects of a high-frequency hearing loss simulated by the high-pass-noise masking method, on the click-evoked brain stem-evoked potentials (BAEP) characteristics in dogs. BAEP were obtained in response to rarefaction and condensation click stimuli from 60 dB normal hearing level (NHL, corresponding to 89 dB sound pressure level) to wave V threshold, using steps of 5 dB in eleven 58 to 80-day-old Beagle puppies. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation potential (RCDP). The procedure was repeated while constant level, high-pass filtered (HPF) noise was superposed to the click. Cut-off frequencies of the successively used filters were 8, 4, 2 and 1 kHz. For each condition, wave V and RCDP thresholds, and slope of the wave V latency-intensity curve (LIC) were collected. The intensity range at which RCDP could not be recorded (pre-RCDP range) was calculated. Compared with the no noise condition, the pre-RCDP range significantly diminished and the wave V threshold significantly increased when the superposed HPF noise reached the 4 kHz area. Wave V LIC slope became significantly steeper with the 2 kHz HPF noise. In this non-invasive model of high-frequency hearing loss, impaired hearing of frequencies from 8 kHz and above escaped detection through click BAEP study in dogs. Frequencies above 13 kHz were however not specifically addressed in this study.  相似文献   

4.
The acoustic reflex (AR) was recorded from 12 healthy mixed-breed dogs. Latency and amplitude were measured from ipsilateral and contralateral AR at stimulus frequencies of 1 and 2 kHz and intensities of 70 to 110 dB sound pressure level for ipsilateral AR and 70 to 120 dB hearing level for contralateral AR. Mean latencies for ipsilateral and contralateral AR were between 33.46 and 206.10 ms and between 45.26 and 180.89 ms, respectively, and amplitudes were between 0.14 and 1.79 cm3 and between 0.31 and 1.86 cm3 of air, respectively. Stimulus frequencies and intensities had significant effects (P less than 0.05) on ipsilateral and contralateral AR latencies and amplitudes. Ipsilateral and contralateral AR decays were determined by measuring compliance change during a 10-s pure-tone stimulation at frequencies of 1 and 2 kHz at an intensity of 10 dB above AR threshold. Reflex decays for 1 kHz and 2 kHz frequencies averaged 5.74% and 9.71%, respectively, for ipsilateral AR and 5.08% and 5.40%, respectively, for contralateral AR. Bilateral tympanograms and brain stem auditory-evoked responses were performed on each dog. Mean normal static compliance of the middle ear, as determined by tympanometry, was 0.15 cm3. Unilateral tenotomy of the tensor tympani muscle was done on 6 of the 12 dogs, and each of the preceding procedures were repeated within 1 week after surgical operation. Transection of the tensor tympani tendon did not alter (P greater than 0.05) the latencies or amplitudes of 1 kHz- or 2 kHz-evoked contralateral AR, the latency or amplitude of 1 kHz-evoked ipsilateral AR, or the amplitude of 2 kHz-evoked ipsilateral AR. However, the latency of 2 kHz-evoked ipsilateral AR was significantly (P less than 0.05) increased. Reflex decay increased significantly (P less than or equal to 0.001) for the contralateral reflex elicited by the 2 kHz stimulus. Neither compliance of the middle ear system nor amplitude and latency of the brain stem auditory-evoked response were affected (P greater than 0.05) by tenotomy. Since tenotomy eliminates participation of the tensor tympani in the AR, these data indicate that contraction of this muscle is not primarily responsible for the compliance changes recorded during an acoustic reflex in dogs.  相似文献   

5.
In dogs, a mean broncho‐arterial ratio of 1.45 ± 0.21 has been previously defined as normal. These values were obtained in dogs under general inhalational anesthesia using a single breath‐hold technique. The purpose of the study was to determine whether ventilation technique and bronchial diameter have an effect on broncho‐arterial ratios. Four healthy Beagle dogs were scanned twice, each time with positive‐pressure inspiration and end expiration. For each ventilation technique, broncho‐arterial ratios were grouped into those obtained from small or large bronchi using the median diameter of the bronchi as the cutoff value. Mean broncho‐arterial ratios obtained using positive‐pressure inspiration (1.24 ± 0.23) were statistically greater than those obtained at end expiration (1.11 ± 0.20) P = 0.005. There was a strong positive correlation between bronchial diameter and broncho‐arterial ratios for both ventilation techniques (positive‐pressure inspiration rs = .786, P < 0.0005 and end expiration rs = .709, P < 0.0005). Mean broncho‐arterial ratio for the large bronchi obtained applying positive‐pressure inspiration was 1.39 cm ± 0.20 and during end expiration was 1.22 cm ± 0.20. Mean broncho‐arterial ratio for the small bronchi obtained during positive‐pressure inspiration was 1.08 cm ± 0.13 and during end expiration was 1.01 cm ± 0.13. There was a statistically significant difference between these groups (F = 248.60, P = 0.005). Findings indicated that reference values obtained using positive‐pressure inspiration or from the larger bronchi may not be applicable to dogs scanned during end expiration or to the smaller bronchi.  相似文献   

6.
Thoracic auscultation is an important diagnostic method used in cases of suspected pulmonary disease in many species, as respiratory sounds contain significant information on the physiology and pathology of the lungs and upper airways. Respiratory diseases are frequent in marine mammals and are often listed as one of their main causes of death. The aim of this study was to investigate and report baseline parameters for the electronic-mediated thoracic auscultation of one cetacean species and two pinniped species in captivity. Respiratory sounds from 20 captive bottlenose dolphins (Tursiops truncatus), 6 California sea lions (Zalophus californianus), and 5 South African fur seals (Arctocephalus pusillus) were recorded with an electronic stethoscope. The sounds were analyzed for duration of the respiratory cycle, adventitious sounds, and peak frequencies of recorded sounds during expiration and inspiration as well as for sound intensity as reflected by waveform amplitude during the respiratory cycle. In respiratory cycles of the bottlenose dolphins' expiring "on command," the duration of the expiration was significantly shorter than the duration of the inspiration. In the examined pinnipeds of this study, there was no clear pattern concerning the duration of one breathing phase: Adventitious sounds were detected most often in bottlenose dolphins that were expiring on command and could be compared with "forced expiratory wheezes" in humans. This is the first report of forced expiratory wheezes in bottlenose dolphins; they can easily be misinterpreted as pathologic respiratory sounds. The peak frequencies of the respiratory sounds reached over 2,000 Hz in bottlenose dolphins and over 1,000 Hz in California sea lions and South African fur seals, but the variation of the frequency spectra was very high in all animals. To the authors' knowledge, this is the first systematic analysis of respiratory sounds of bottlenose dolphins and two species of pinnipeds.  相似文献   

7.
The technique of impedance plethysmography is described and its application to observation of lung volume changes in the horse at exercise is discussed. The results from horse at rest show that there is a close relationship between rate of lung volume change (flow rate) and the associated impedance changes during both inspiration and expiration. Impedance changes during exercise were related to inspiration and expiration by observation of associated respiratory sounds. Artefacts related to technical difficulties are also indicated.  相似文献   

8.
Tracheobronchomalacia has been diagnosed using radiography or bronchoscopy to confirm bronchial changes in luminal diameter during the respiratory cycle. However, studies in healthy humans suggest that some degree of bronchial collapse may be observed during the normal respiratory cycle. In this analytical study, the luminal diameter of the bronchus to each of the six pulmonary lobes and the mean percentage of expiratory collapse from end inspiratory, end expiratory, and two forced expiratory phases (10 and 15 ml/kg) were determined via computed tomography (CT) and radiography in 22 healthy Beagle dogs. The bronchial collapsibility was significantly greater during the forced expiration than the end expiration (< 0.001); the same results were observed in dorsal and sagittal CT images and radiographs (P < 0.001). Median collapsibility values associated with 15 ml/kg forced expiratory collapse determined via cross‐sectional CT images were measured as 16.6–45.5% and differed according to the pulmonary lobe. Median collapsibilities on radiography with 15 ml/kg forced expiration were 57.8% and 62.1% in the right cranial lobe and right caudal lobe, respectively. In conclusion, bronchial diameter may change during the respiratory cycle, and some degree of reduction in bronchial diameter may be an incidental finding in healthy dogs. More rigorous criteria are needed with regards to bronchial collapsibility during normal respiration for the diagnosis of bronchomalacia in order to avoid false‐positive diagnoses.  相似文献   

9.
PCR detection of microbial pathogens in blood from patients is a promising issue for rapid diagnosis of sepsis and early targeted therapy. However, for PCR assays detecting all bacterial groups, broad range primers, in particular the 16S rDNA targeting primers have to be used. Upcoming false signals and reduced sensitivity are a common problem as a consequence of unspecific amplification reactions with the human DNA background. Here we show that, using total DNA extracts from blood, unspecific signals occurred in general 16S rDNA PCRs as a result of the amplification of human sequences. To address this problem, we developed a protocol by which the human background DNA is removed and bacterial DNA is enriched during sample preparation, a method we termed background-free enrichment method (BFEM). In general, we aimed to exclude false signals due to the human background DNA yielded from 16S rDNA PCR, Real-Time-PCR and IGS-PCR analyses. We applied the BFEM to the analysis of blood samples from 22 patients and obtained results similar to standard blood culture methods. The BFEM allows specific and sensitive detection of pathogens in downstream PCR assays and is easy to handle due to the quick sample preparation procedure. Thus, the BFEM contributes to the generation of replicable and more reliable data in general 16S rDNA PCR assays.  相似文献   

10.
OBJECTIVE: To evaluate the association among clinical signs, results of cytologic evaluation of bronchoalveolar lavage (BAL) fluid, and measures of pulmonary function in horses with inflammatory respiratory disease. ANIMALS: 9 healthy horses, 5 horses with inflammatory airway disease (IAD), and 9 horses with chronic obstructive pulmonary disease (COPD). PROCEDURES: Clinical examination, lung function tests, and BAL were performed on each horse. RESULTS: Standard lung mechanics of horses with exacerbated COPD differed significantly from those of healthy horses; however, there were few differences among horses with IAD, horses with COPD during remission, and healthy horses. Most variables for forced expiration (FE) in horses with COPD or IAD differed significantly from those for healthy horses. Results of clinical examination had low to moderate sensitivity and predictive values for a diagnosis of COPD (range, 67 to 80%). Results of FE tests had high sensitivity, specificity, and predictive values for a diagnosis of COPD (79 to 100%), and results of standard lung mechanics tests had low sensitivity and predictive values (22 to 69%). Percentage of neutrophils in BAL fluid was highly sensitive (100%) but moderately specific (64%) for a diagnosis of COPD. CONCLUSIONS AND CLINICAL RELEVANCE: Clinical examination is moderately accurate for establishing a diagnosis of COPD. Forced expiration tests can specifically detect early signs of airway obstruction in horses with COPD and IAD that may otherwise be inapparent. Cytologic evaluation of BAL fluid allows early detection of inflammatory respiratory disease, but it is not specific for COPD.  相似文献   

11.
Tracheal ultrasonography was performed to measure the width of the tracheal ring shadow and to assess the clinical relevance of these measurements for identifying tracheal collapse. The first tracheal ring width (FTRW) and thoracic inlet tracheal ring width (TITRW) were measured on both expiration and inspiration. The mean of the FTRW width (129 dogs) was greater in expiration (10.97 ± 1.02 mm, p = 0.001) than that in inspiration (9.86 ± 1.03 mm). For 51 normal dogs, the mean of the TITRW width was greater in expiration (9.05 ± 1.52 mm, p = 0.001) than in inspiration (8.02 ± 1.43 mm). For 78 tracheal collapse dogs, the mean of the TITRW width was greater in expiration (15.89 ± 1.01 mm, p = 0.001) than in inspiration (14.85 ± 1.17 mm). The TITRW/FTRW ratio of the normal dogs was higher (p = 0.001) in expiration (0.81 ± 0.09) than that in inspiration (0.79 ± 0.10). When compared between the normal and tracheal collapse dogs, the TITRW/FTRW ratio was also increased (p = 0.001) both in expiration (1.54 ± 0.09) and inspiration (1.47 ± 0.08), respectively. Based on these results, the cutoff level of the TITRW/FTRW ratio was statistically analyzed according to the receiver operating characteristic curve and it could be set at 1.16 in expiration and at 1.13 in inspiration. We have demonstrated that tracheal ultrasonography is a useful technique for the evaluation of tracheal collapse and it can be a supportive tool together with the radiographic findings for making the correct diagnosis.  相似文献   

12.
The use of electron microscopy to assist in the rapid diagnosis of virus diseases of veterinary importance is reviewed. Electron microscopy can be used to assist the laboratory diagnosis of a virus disease at two stages during the investigation; either by demonstrating virus in clinical material or by identifying isolates from tissue culture or similar systems. Direct electron microscopy and immunoelectron microscopy are particularly useful for rapid diagnosis. The advantages of electron microscopy lie in speed and flexibility, and the disadvantages in the high particle concentration needed and the presumptive nature of a diagnosis.  相似文献   

13.
OBJECTIVE: To record respiratory sounds in exercising horses and determine whether spectrum analysis could be use to identify sounds specific for laryngeal hemiplegia (LH) and dorsal displacement of the soft palate (DDSP). ANIMALS: 5 Standardbred horses. PROCEDURE: Respiratory sounds were recorded and pharyngeal pressure and stride frequency were measured while horses exercised at speeds corresponding to maximum heart rate, before and after induction of LH and DDSP. RESULTS: When airway function was normal, expiratory sounds predominated and lasted throughout exhalation. After induction of LH, expiratory sounds were unaffected; however, all horses produced inspiratory sounds characterized by 3 frequency bands centered at approximately 0.3, 1.6, and 3.8 kHz. After induction of DDSP, inspiratory sounds were unaffected, but a broad-frequency expiratory sound, characterized by rapid periodicity (rattling) was heard throughout expiration. This sound was not consistently detected in all horses. CONCLUSIONS AND CLINICAL RELEVANCE: The technique used to record respiratory sounds was well tolerated by the horses, easy, and inexpensive. Spectrum analysis of respiratory sounds from exercising horses after experimental induction of LH or DDSP revealed unique sound patterns. If other conditions causing airway obstruction are also associated with unique sound patterns, spectrum analysis of respiratory sounds may prove to be useful in the diagnosis of airway abnormalities in horses.  相似文献   

14.
AIM: To improve the outcome of parameters measured by the impulse oscillometry system (IOS) in horses by separate assessment of inspiratory and expiratory impedance spectra in the frequency range between 1 and 10 Hz. As basis for further studies, the influence of sedation with xylazine on respiratory impedance was also investigated. METHODS: (i) The respiratory impedance of 11 horses was measured using IOS before and 6 min after sedation (xylazine; 0.6 mg/kg b.w.). (ii) The time course of impedance parameters in a period of 24 min after administration of xylazine was evaluated in 12 horses at regular intervals of 3 min. Resistance (R(rs)), reactance (X(rs)), and coherence (Co) were calculated as mean spectra (R(rs),X(rs),Co) of the entire measurement as well as separated into inspiration (Ri(rs),Xi(rs),Coi) and expiration (Re(rs),Xe(rs),Coe) at frequencies of 1, 5, and 10 Hz. RESULTS: (i) R(rs), X(rs) as well as Re(rs) and Xe(rs) revealed no significant influence of sedation. However, separate analysis of inspiration and expiration revealed a significant influence of sedation on all inspiratory impedance parameters. (ii) During the 24 min period after sedation, almost all inspiratory parameters were found significantly dependent on the time course of sedation whereas expiratory parameters Re10, Xe1, and Xe5 were not influenced. These results indicate that confounding factors due to sedation act mainly during inspiration. Muscle relaxation in upper airways due to xylazine is suspected to be the main cause of these phenomena.  相似文献   

15.
OBJECTIVE: To evaluate auditory maturation in puppies. ANIMALS: Ten clinically normal Beagle puppies. PROCEDURE: Puppies were examined repeatedly from days 11 to 36 after birth (8 measurements). Click-evoked brain stem auditory-evoked potentials (BAEP) were obtained in response to rarefaction and condensation click stimuli from 90 dB normal hearing level to wave V threshold, using steps of 10 dB. Responses were added, providing an equivalent to alternate polarity clicks, and subtracted, providing the rarefaction-condensation differential potential (RCDP). Steps of 5 dB were used to determine thresholds of RCDP and wave V. Slope of the low-intensity segment of the wave V latency-intensity curve was calculated. The intensity range at which RCDP could not be recorded (ie, pre-RCDP range) was calculated by subtracting the threshold of wave V from threshold of RCDP RESULTS: Slope of the wave V latency-intensity curve low-intensity segment evolved with age, changing from (mean +/- SD) -90.8 +/- 41.6 to -27.8 +/- 4.1 micros/dB. Similar results were obtained from days 23 through 36. The pre-RCDP range diminished as puppies became older, decreasing from 40.0 +/- 7.5 to 20.5 +/- 6.4 dB. CONCLUSION AND CLINICAL RELEVANCE: Changes in slope of the latency-intensity curve with age suggest enlargement of the audible range of frequencies toward high frequencies up to the third week after birth. Decrease in the pre-RCDP range may indicate an increase of the audible range of frequencies toward low frequencies. Age-related reference values will assist clinicians in detecting hearing loss in puppies.  相似文献   

16.
There are many causes of respiratory failure in veterinary patients. Assessment of oxygenation is imperative for the diagnosis and monitoring of these patients. Oxygen therapy should be instituted when hypoxemia is diagnosed to prevent tissue hypoxia, end-organ damage, and death. Methods of administering oxygen include commercial oxygen cages, mask oxygen, nasal cannulation (for dogs), and intubation. Mechanical ventilation is an option in many referral hospitals for patients who are severely hypoxemic and are not responding to inspired oxygen concentrations achieved with other methods of oxygen administration. One rule of thumb used to assess need for mechanical ventilation is a PaO2 of less than 50 mm Hg despite aggressive oxygen therapy, or a PaCO2 of greater than 50 mm Hg despite treatment for causes of hypoventilation. A mechanical ventilator has the ability to vary the FiO2 by increments of one, from 21% to 100% (0.21-1) oxygen in inspired gas. Positive end-expiratory pressure (PEEP) is also available on most ventilators. PEEP allows the alveoli to remain open on expiration, allowing gas exchange to occur in both inspiration and expiration. PEEP also helps diseased alveoli to inflate, increasing the available surface area for gas exchange and improving arterial blood oxygen tension. Because patients requiring mechanical ventilation have severe respiratory failure that did not respond to conventional oxygen therapy, the prognosis is guarded for most of these patients unless ventilation is instituted due to primary hypoventilation and lung parenchyma is normal. Hypoxemia caused by respiratory failure is a common problem in small animal veterinary patients. Assessment of blood oxygenation and continual monitoring of respiratory rate and effort are essential in management of these patients. Oxygen therapy should be instituted if hypoxemia is diagnosed. The prognosis depends on the underlying disease process and response to treatment with an enriched oxygen environment.  相似文献   

17.
Inflammatory airway disease (IAD) is common in racehorses, and is a cause of wastage in the industry. IAD has been diagnosed by measurement of percent neutrophils (N%) in tracheal aspirates (TA). The aim of this study was to investigate whether spirometric indices of pulmonary function were correlated with N% in TAs. Limits to breathing were measured by analyses of relationships between relative times and relative respiratory gas flows during inspiration and expiration in individual breaths recorded after exercise. Horses with higher N% had significantly lower relative gas flows at the same relative times during inspiration and expiration, suggesting a limit to breathing. These findings confirm a physiological basis for the measurement of N% in TA after exercise for diagnosis of IAD. Spirometric pulmonary function testing using analyses of individual breaths after exercise has application for assessment of pulmonary function and poor exercise performance.  相似文献   

18.
The antibody response of 20 pregnant ewes to oocyst infection with Toxoplasma gondii was determined by the latex agglutination test (LAT) and compared with the indirect fluorescent antibody test (IFAT) and a commercially available indirect haemagglutination test (IHAT). The LAT and IFAT showed a similar rapid response with antibody first appearing by two to three weeks after infection and titres that correlated closely (r = 0.81, P less than 0.001). The IHAT response was slower and less consistent up to seven weeks after infection. The LAT response was biphasic in seven of the sheep. Sera were fractionated using a minicolumn gel filtration technique and specific IgM and IgG titres determined by LAT. IgM titres peaked three weeks after infection and IgG titres exceeded IgM titres at a mean time of 4.7 weeks after infection (range 3 to 7). Eleven sheep exhibited fetopathy with abortion/parturition 12 to 53 days after infection; in nine of them IgG titres exceeded IgM at that time. A non-specific anti-toxoplasma reaction associated with IgM antibody occurred at low titre in one sheep. The results indicate that used from a dilution of 1/64 the LAT is a sensitive, reliable and rapidly responsive serological test for toxoplasma infection in ewes and it may be utilised with sample fractionation techniques to determine IgM titres. It is suggested that the best time to examine ewe sera to assist diagnosis of toxoplasma abortion is one week after abortion. While the determination of specific IgM titres in ewe sera may assist epidemiological studies and, sometimes, diagnosis, in the majority of aborting ewe sera it is unlikely to aid diagnosis.  相似文献   

19.
Phonocardiography was evaluated as a noninvasive technique for diagnosis of cardiovascular adaptation and disease in broiler chickens. Heart sounds (HSs) were compared in a fast-growing (FG) commercial broiler line that is highly susceptible to chronic right heart failure resulting from pulmonary hypertension syndrome (PHS) and in a non-selected slow-growing (SG) broiler line that is resistant to PHS. HSs were analyzed in broilers reared in hypobaric hypoxia (HYP) and normobaric (CON) conditions. PHS was induced by a combination of embryonic hypoxia and HYP exposure. HSs were recorded with a microphone placed at the thoracic inlet of each chicken. Electrocardiograms were used to mark the sampling interval for the first, second, and total HS. Digitized HS signals were analyzed for peak frequency, mean peak frequency, and band width. Birds were examined for PHS lesions when 6 wk of age, at the end of each experiment. HSs were compared by line and treatment (Experiment 1) or by treatment and week (Experiment 2). In addition, HS frequencies were analyzed within the HYP treatment group for differences between birds with severe or no gross PHS lesions. HS frequencies generally decreased with age and were also lower in the FG than the SG line. Hypobaric exposure decreased all HS frequencies in the SG line and components of the first HSs in the FG line. The SG line did not develop gross lesions of PHS. In the FG line, significant differences in HS frequencies were observed between HYP and CON groups but not between PHS- and PHS+ broilers. Frequency changes described in humans with PHS were not observed. Further development to maximize the resolution of the HS waveforms and improved matching of the sampling interval to the electrical or hemodynamic output of the chicken heart may allow its use as a diagnostic tool for differentiating broilers with normal cardiac function or physiologic adaptation from those with cardiovascular disease.  相似文献   

20.
Background: Botulism is a potentially fatal paralytic disorder for which definitive diagnosis is difficult. Objectives: To determine if repetitive stimulation of the common peroneal nerve will aid in the diagnosis of botulism in foals. Animals: Four control and 3 affected foals. Methods: Validation of the test in healthy foals for its comparison in foals with suspected botulism. Controls were anesthetized and affected foals were sedated to avoid risks of anesthesia. The common peroneal nerve was chosen for its superficial location and easy access. Stimulating electrodes were placed along the common peroneal nerve. For recording, the active and reference electrodes were positioned over the midpoint and distal end of the extensor digitorum longus muscle, respectively. Repeated supramaximal stimulation of the nerve was performed utilizing a range of frequencies (1–50 Hz). Data analysis consisted of measuring the amplitude and area under the curve for each M wave and converting these values into percentages of decrement or increment based on the comparison of subsequent potentials to the initial one (baseline) within each set. Results: A decremental response was seen at all frequencies in control foals. Decremental responses also were observed in affected foals at low frequencies. An incremental response was seen in all affected foals at 50 Hz. Conclusions and Clinical Importance: Decreased baseline M wave amplitudes with incremental responses at high rates are supportive of botulism. Repetitive nerve stimulation is a safe, simple, fast, and noninvasive technique that can aid in the diagnosis of suspected botulism in foals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号