首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 607 毫秒
1.
日光温室是一个体形系数很大的设施农业建筑,温室的建筑墙体构造方式及其建筑材料热物性等都直接影响墙体保温与蓄热特性乃至温室热环境。该研究基于课题组研发的GH-20相变材料,以传统墙体、被动式太阳能相变蓄热"三重"墙体、主-被动式太阳能相变蓄热"三重"墙体为比较研究对象,结合实测结果,分析比较了墙体构筑方式、材料热物性等因素对日光温室墙体热性能的影响规律。研究结果表明,较传统墙体,被动式太阳能相变蓄热"三重"墙体、主-被动式太阳能相变蓄热"三重"墙体的表面温度夜间明显高于传统墙体,早晨保温被开启时相差最大,为3.0℃;传统墙体中间层温度变化幅度最小,主-被动式墙体中间层的温度变化幅度明显提高,最大为14.4℃、最小为2.2℃、平均为7.5℃,中间墙体层的显热蓄热"热库"作用显现;夜间,被动式太阳能相变蓄热"三重"墙体、主-被动式太阳能相变蓄热"三重"墙体的放热量分别提高了103%和118%,其中51%的放热量在后半夜(2:00~10:00)释放,有效地改善了夜间温室热环境,相变材料的"热量开关"作用显现。  相似文献   

2.
为研究以农作物秸秆为墙体材料的日光温室(以下称秸秆块墙体日光温室)的保温蓄热性能,以秸秆块墙体日光温室为研究对象,以空心砖墙体日光温室为对照,监测了两种墙体材料温室中空气、墙体、土壤和温室各界面温度变化,分析了两种墙体材料日光温室的保温蓄热性能。结果表明:秸秆块墙体在晴天和阴天时均具有很好的保温性能,空心砖墙体晴天夜间时散失的热量是秸秆块墙体的1.5倍,阴天夜间时散失的热量是秸秆块墙体的1.3倍;秸秆块和空心砖墙体日光温室阴天时室内最低气温分别为5.4 ℃和5.8 ℃,晴天时室内最低气温为6.0 ℃和7.4 ℃;秸秆块墙体温室中40 cm以上土壤平均温度(14.00±2.61)℃高于空心砖墙体温室(13.55±1.73)℃。温室结构中各界面表面温度主要受太阳辐射强度的影响,秸秆块墙体温室中10 cm以上土壤层和空气的蓄热量比空心砖墙体温室中的大,秸秆块墙体的蓄热量比空心砖墙体的蓄热量小。  相似文献   

3.
针对日光温室后墙保温、蓄热能力不足的问题,选取装配式砾石模块日光温室(A)和装配式土模块日光温室(B)为试验温室,以当地传统的砖混结构温室(C)为对照,测试试验及对照温室的室内温度和试验温室A和B的墙体温度以及墙表面热流密度,分析试验温室和对照温室的环境温度差异以及2座试验温室的墙体传热特性。结果表明:试验温室后墙热工性能方面,B温室的总热阻和墙体总热惰性指标均大于A温室,温度波传至墙内表面的衰减倍数和延迟时间更大;室内温度方面,晴天B温室的夜间平均气温分别比A和C温室高0.6和2.7 ℃,阴天的夜间平均气温分别高0.9和3.3 ℃,雨天的夜间平均气温分别高1.9和4.3 ℃;墙体方面,晴天B温室的墙体蓄热层厚度为600~700 mm,墙体厚度>700 mm为稳定层,阴天蓄热层厚度为300~400 mm,墙体厚度>400 mm为稳定层,典型天气下A温室的墙体蓄热层厚度均>600 mm,蓄热层厚度的差异是A温室墙体的材料孔隙大,密闭性差造成;墙体传热特性方面,晴天整日蓄热量B温室比A温室高168.24 MJ,阴天高14.09 MJ。综上,试验温室A和B热性能优于对照温室C,B温室的保温、蓄热性能最优。  相似文献   

4.
为探讨苗期不同水肥耦合模式对冬草莓光合特性、产量和灌溉水利用效率的影响,寻找适合温室冬草莓的水肥耦合模式,以‘丰香’草莓为试材,设置3个灌水水平(低水、中水和高水的灌水量分别为2.4mm、3.6mm和4.8mm)和2个施肥水平(低肥、高肥的单次施肥量分别为45kg/hm2、90kg/hm2),同时设置对照处理(CK,灌水量为6.0mm、单次施肥量为75kg/hm2)。结果表明:与CK相比,低肥水平下不同灌水处理的冬草莓Pn、Tr和Gs分别降低9.9%~40.8%、15.2%~35.7%和14.0%~27.9%,高肥中水、高肥高水处理的Pn、Tr和Gs分别提高4.0%、2.4%、4.7%和13.3%、5.2%、2.3%;不同施肥水平下高水处理草莓的WUEi提高6.3%~7.6%;高肥中水、高肥高水处理的产量提高3.2%、3.5%,灌溉水利用率提高7.5%、11.8%。综合比较苗期冬草莓光合特性以及产量和灌溉水利用率,高肥高水(施肥90kg/hm2,灌水16mm)是温室冬草莓苗期较适宜的水肥耦合模式。  相似文献   

5.
测试和田沙漠组装式温室的光热环境,尤其是温室的蓄放热量及保温能力,为和田地区日光温室性能做出评价,采用数据记录仪对温室内外环境的光热环境进行测定,结果表明,晴天光照度平均为18058 lx,空气温度可达40℃以上,且土层越深,地温越稳定;地面蓄热时平均热流密度为47.85 W/m2,放热时平均热流密度为16.91 W/m2;土壤表面温度和空气平均值分别为15.47、15.30℃;最大值可达37.90、45.00℃;墙体吸热时平均热流密度为13.91 W/m2,放热时平均热流密度为5.40 W/m2;墙体表面温度和空气温度平均值分别为15.76、14.61℃,最大值可达72.10、55.30℃;地面白天最大蓄热量为2.03 MJ/m2,地面最大放热量为1.35 MJ/m2,墙体白天最大蓄热量为0.76 MJ/m2,墙体最大放热量为0.40 MJ/m2.从温光特性方面来看,沙漠组装式温室各环境因子变化较大,温室内部空气温度、墙体温度、地表温度波动较大,热稳定较差;地面是主要的蓄放热体,温室墙体蓄热量、放热量很小,难以起到稳定温室夜间温度的作用.  相似文献   

6.
东北地区日光温室保温性能实验研究   总被引:3,自引:0,他引:3  
本文通过对不同天气条件下我国东北地区日光温室各围护结构保温性能的实验研究,得出各结构表面温度与室内外温度关系,以及表面蓄热放热变化规律。实验结果表明:冬季夜间土壤为日光温室主要热源,提高墙体的蓄热隔热性能是改善温室热环境的重要方面。本研究为今后完善温室的优化设计提供理论依据。  相似文献   

7.
日光温室复合墙与土墙热性能对比分析   总被引:7,自引:0,他引:7  
为了分析复合墙和土墙保温蓄热能力的差异,对同热阻、同热惰性指标的两组复合墙和土墙温室,在边界条件相同的情况下对二者的热性能进行了对比分析.结果表明:夜间同热阻土墙温室的空气温度高于复合墙温室0.5℃,复合墙温室的空气温度高于同热惰性指标土墙温室1.0℃.同热阻土墙、复合墙的内表面温度差异不明显,而同热惰性指标土墙内表面则出现1.5℃的温差.同热阻土墙和复合墙在夜间(22:00)向室内方向放热的墙体厚度均为100mm.复合墙温室墙体蓄热性及热稳定性均好于同热阻或同热惰性指标土墙温室.  相似文献   

8.
为了研究复合相变墙体对日光温室热环境及乳瓜生长发育的影响,以北墙为土捣墙的日光温室为对照,对温室内环境参数(热通量、北墙内表面温度、气温、土壤温度)及乳瓜生长参数(叶片、茎、果实的生长状况)进行比较.结果表明:温室北墙涂抹40 mm相变材料可提升墙体吸放热的性能,且白天蓄热和夜间放热通量均高于对照温室.墙体内表面温度呈现出相变涂层温室好于对照温室,最高增加0.4℃.试验期间,相变涂层温室的旬平均气温总是高于对照温室,最高增加0.3℃,且温室内最高温度呈现出相变涂层温室小于对照温室,所以相变材料放热使得室内温度略高于对照温室,室内温度波动幅度大大减少.相变涂层温室的日均土壤温度高于对照温室,最高增加5.7℃.2个温室乳瓜的株高均与日均气温、日均土壤温度呈极显著正相关,且相变涂层温室处理的相关系数大于对照处理.在整个生育期,相变涂层温室内的乳瓜株高较对照温室增加12.7%,茎粗增加1.5%,叶面积增加2.9%.与对照温室相比,相变涂层温室内乳瓜维生素C含量、总糖含量、横宽分别增加41.9%、27.9%、9.8%.该试验结果对宁夏日光温室后墙墙体材料和相变温室种植作物选择提供理论依据.  相似文献   

9.
拆装型黄麻纤维后墙温室墙体传热特性研究   总被引:2,自引:0,他引:2  
[目的]为实现日光温室的全年型生产,设计了拆装式黄麻纤维后墙温室,以探讨黄麻纤维材料作为温室拆装墙体的可行性。[方法]以拆装式黄麻纤维后墙温室为试验温室,以当地传统黏土砖后墙日光温室为对照,对温室墙体的热工性能、传热特性以及室内热环境进行了试验研究。[结果]冬季温室内部气温保持在4℃以上,黄麻墙结构保温效果良好;夏季黄麻墙拆除后,室内最高气温在40℃以下。温室墙体内、外表面温度受太阳辐射及室内、外气温的共同影响,呈现与气温相同的日变化规律。室内气温、墙面温度影响墙内各深度层次的温度分布,温度的总体变化趋势是由内表面向外表面沿厚度方向递减。与砖墙相比,黄麻墙蓄热性能较低,但保温隔热效果较好,能量利用率较高。[结论]黄麻纤维材料保温隔热性能较好,质量轻便于安装与拆卸且建造与维护成本较低,因此可作为一种新型温室墙体材料。  相似文献   

10.
复合微生物菌肥对连作草莓产量和品质的影响   总被引:12,自引:0,他引:12  
研究了复合微生物菌肥对连作草莓营养生长及产量和品质的影响.结果表明:菌肥处理明显促进草莓营养生长,提高草莓产量和果品质量.其中,菌肥浓度37.5kg/hm2处理的草莓产量最高,前期产量和总产量分别较CK提高了6.74%和5.54%;菌肥处理草莓果实的糖酸比、可溶性固形物和Vc含量分别较CK提高了11.5%、20.0%、17.2%和30.2%,差异显著.  相似文献   

11.
日光温室墙体一维导热的MATLAB模拟与热流分析   总被引:1,自引:0,他引:1  
为探明日光温室墙体层间温度变化及热量传递动态规律,采用有限差分法建立墙体一维非稳态导热模型,利用MATLAB编制相应的模拟程序,计算出日光温室墙体各点的温度和热流。结果表明:该模型能够比较准确模拟日光温室土墙的温度。墙体内侧存在有效蓄热层,它对日光温室室内热环境有积极的作用。墙体有效蓄热层的热流白天指向墙体外侧,夜间指向墙体内侧,因此它的厚度直接根据热流的方向确定。有效蓄热层与天气、墙体总厚度以及墙体热特性参数有关。2012-12—2013-01期间有效蓄热层厚度为0.26~0.45m不等,最大值出现在连续雪天。同时从理论上验证了3.0m厚的温室土墙内部存在热流相对稳定的"热稳定层"。  相似文献   

12.
Solar greenhouse with trapezoidal soil wall is widely used due to its good heat retaining property and cost efficiency.In this study, solar irradiance, heat flux and the temperature 0.05 and 0.3 m from the inner surface of the wall at the upper,middle and lower measured positions were determined to study the thermal condition of the trapezoidal soil wall in solar greenhouse. The results showed: first, both the solar irradiance and the temperature increased from the upper to the lower measured position. Second, the heat absorption also increased from the upper to the lower measured position. In clear day, the heat absorption at the three measured positions accounted for 31.4%, 32.6% and 36.0% of the total amount of heat absorption of the whole wall. In cloudy day, the heat absorption at the three measured positions were 0.249, 0.370 and 0.440 MJ/m~2, which accounted for 23.5%, 35.0% and 41.4% of the total amount of heat absorption of the whole wall. When P0.05, the heat fluxes were strikingly different between the upper and lower measured positions. But when P0.01, the heat flux had no big difference among the three measured positions. Third, in clear day, the heat emission was the biggest at the middle measured position and smallest at the upper measured position. The heat emission at the three measured positions accounted for 27.5%, 36.7%and 35.8% of the total amount of heat emission of the whole wall. And the heat emission between the middle and lower measured position was not strikingly different. In cloudy day, the heat emission was the biggest at the lower measured position and smallest at the upper measured position. The average heat emission at the three measured positions accounted for 26.1%,36.4% and 37.4% of the total amount of heat emission of the whole wall. Fourthly, correlativity, the solar irradiance directly influenced the heat absorption and had close relation with heat emission. And heat emission again had close relation with the temperature in the greenhouse. Solar irradiance directly influences the thermal condition of a solar green house. It is hoped that this study can be referred to optimize trapezoidal structure and to improve the thermal conditions of the solar greenhouse.  相似文献   

13.
磷酸氢二钠相变墙板在温室中的应用效果   总被引:5,自引:0,他引:5  
为改善日光温室热环境,以十二水磷酸氢二钠为相变材料,依据普通温室墙体夜间累计放热量计算出相变材料的用量为16.7kg/m2,在此基础上制备了十二水磷酸氢二钠相变蓄热墙板。建造后墙结构为"80mm相变蓄热板+40mm×60mm×2.5mm方钢+80mm菱镁聚苯保温板"日光温室,与"240mm红砖+100mm聚苯板+240mm红砖"后墙温室比较。结果表明:典型晴天时,相变蓄热板温室的气温波动幅度比对照小4.2℃,最低气温高1.5℃,最高气温低2.7℃,平均气温高1.2℃,相对湿度增加3%,墙体夜间累计放热量略大于对照;典型阴天时,相变蓄热板温室的平均气温比对照高1.6℃,相对湿度提高2.6%,墙体夜间累计放热量增加0.16MJ/m2。与此同时相变蓄热板墙体造价比对照低22元/m2,土地利用率提高4.2%~12.2%。综合保温蓄热性能和建造成本,相变蓄热墙板是一种有推广价值的温室墙体类型。  相似文献   

14.
新疆砌块复合墙体和砖墙日光温室的传热数值模拟分析   总被引:1,自引:0,他引:1  
[目的]研究建立新的二维传热模型来模拟和优化日光温室,为日光温室墙体的设计、建设和维护提供科学合理的方法和依据.[方法]采用ansys软件进行温度场和流场模拟,使用UG软件对日光温室造型,将顶部保温被等结构适当简化,计算域分为内部与外部空气两部分.运用DO辐射模型和湍流模型模拟,采用CFX-Post计算处理,得到温度云...  相似文献   

15.
张纪涛  李翠 《农学学报》2019,9(5):62-68
砖墙日光温室是重要的温室类型,但建设成本高、越冬性能不佳。为明确砖墙日光温室结构蓄放热特点,为日光温室标准化设计提供指导,本研究监测分析了砖墙日光温室热环境及结构的蓄放热特征。通过不同时段的监测分析得到以下几个结果:(1)砖墙日光温室0~20cm深度的土壤为蓄热层;0~25cm的墙体为蓄热层;(2)栽培面和墙体在白天蓄热,在夜间室内气温降低后,逐渐向室内散热,但小于通过前后屋面散失的热量,测试期间散热比放热高0.64MJ.m-1;(3)日光温室外表面一直处于散热状态。在不考虑其他散热损失的条件下,前屋面、后屋面、后墙、侧墙在夜间(18:00~次日8:00)的散热分别占总散热量的76.1%、10.7%、11.5%、1.7%。通过以上结果分析,改善日光温室热环境应采用综合的工程方法,以控制整体建设成本,即实现合理的蓄热保温。本研究对促进日光温室标准化的实现有重要指导作用,进而可以促进设施建设的向现代化、标准化方向发展。  相似文献   

16.
日光温室是中国北方地区独有的一种温室类型,对提高农民生产效益和改善人们生活水平起到了极大的作用。为了明确日光温室工程技术的发展水平和方向,本文总结了近年来在日光温室墙体结构优化、创新型日光温室类型、保温蓄热工程技术、光伏日光温室等方面的相关研究报道,并探讨了日光温室在建构和热环境工程方面的发展方向。日光温室工程发展趋势:(1)日光温室建构向轻简化、标准化方向发展;(2)日光温室设施与装备向高效与节能化发展;(3)日光温室环境调控和管理向精准化和智慧化方向发展。研究可为日光温室优化热环境工程技术的发展提供参考。  相似文献   

17.
【目的】研究日光温室基质培条件下,不同氮磷钾用量对茄子产量、根系生长和根际基质中微生物数量及酶活性的影响,为基质培茄子氮磷钾养分合理施用提供理论依据。【方法】采用基质槽栽和水肥一体化滴灌方式,以前期试验得到的基质配方沙子:炉渣:菇渣=6:3:1(体积比)为栽培基质,以不施肥处理为对照(CK),以目标产量施肥量(目标产量施肥量=(目标产量需肥量-基质中速效养分含量)/化肥利用率)设定100%施肥量(F4),在此基础上,分别减少60%(F1)、40%(F2)、20%(F3)及增加20%(F5)和40%(F6)施肥量,研究氮磷钾用量对茄子产量、根系发育和根际基质微生物数量和酶活性的影响。【结果】茄子单株产量随氮磷钾用量增加呈先增高后降低的趋势,较CK增产幅度为101.1%—212.9%,F3处理下单株产量最高,比CK高212.9%(P<0.05)。根际基质中微生物以细菌为主,其次为放线菌,真菌较少。定植90 d后,随氮磷钾施用量增加,茄子根际基质中速效氮、磷、钾含量逐渐增加,细菌、真菌和放线菌数量,蔗糖酶、过氧化氢酶和碱性磷酸酶活性呈先升高后降低的趋势,F3处理下均较高,高氮磷钾处理(F4、F5和F6)下脲酶活性较高;根系活力、根系总长度和根系表面积呈先增加后降低的趋势,在F2处理下较高,分别较CK增加109.2%、49.2%和46.5%,差异显著。细菌数量与基质酶活性呈显著正相关,脲酶活性与速效氮、磷、钾含量呈极显著正相关,过氧化氢酶、碱性磷酸酶活性与速效磷、钾含量呈显著正相关;细菌数量、过氧化氢酶活性与根系活力和产量呈极显著正相关,脲酶活性、速效磷、速效钾含量与根系活力和产量呈显著正相关,根系活力与单株产量呈极显著正相关。【结论】在沙子:炉渣:菇渣=6:3:1(体积比)的栽培基质条件下,日光温室冬春茬茄子的适宜氮磷钾用量分别为N 180.6 kg·hm-2、P2O5 212.1 kg·hm-2、K2O 434.9 kg·hm-2,依此量施肥有利于茄子产量、根系活力和基质微生物数量及酶活性的提高,可为茄子生长提供良好的微生态环境。  相似文献   

18.
日光温室后屋面内设反光幕环境效应分析   总被引:1,自引:0,他引:1  
为研究日光温室后屋面内设反光幕对室内环境和植株的影响,在秋冬季节测定了反光幕对日光温室室内光强、温度、湿度和植株株高、茎粗的影响。结果表明:后屋面张挂反光幕有补光效果,室内光照强度平均增加7%~14%,可缓解温室内南北方向光分布不均,室内温度增加1.8~7.2℃;同时温室内植株茎粗平均提高1mm,且改善了室内植株南北高度不均的问题。因此,冬季在温室后屋面张挂反光幕,既可以补光又不影响后墙正常蓄热保证室内温度。  相似文献   

19.
南方日光温室的结构、环境特点及应用效果   总被引:1,自引:0,他引:1  
南方日光温室是一种冬季保温效果优良的设施类型,其长度50 m,跨度8 m,南面肩高1.7 m,北面顶高3.85 m。东、西、北三面由支柱、聚氨基泡沫板、多功能薄膜为主要材料构成可以拆卸的保温墙,南面由钢管弯曲而成的屋架、支柱及覆盖在屋架上的多功能薄膜、保温被和卷帘机组成。为了加强通风降温性能,在南、北屋面和北保温墙上都设计安装了通风窗。南方日光温室光照强度、温度的日变化呈现出早晨和傍晚较低、中午高的趋势,湿度则呈相反的趋势。与普通大棚相比,南方日光温室的总进光量较大。由于南方日光温室夜间有外保温被覆盖,与露地温差可达4.7~12.7℃,可使室内气温维持在5℃以上。南方日光温室的气温晴天上升较快,中午可达到40℃以上,需开窗通风降温。由于南方日光温室密封性较好、温度高、相对湿度高,需适当通风降湿。番茄种植的结果表明,南方日光温室可明显改善一月、二月和三月份番茄生长的环境条件,生长期和采收期可延长一个月,产量增加20%~50%。  相似文献   

20.
放线菌对对羟基苯甲酸的降解作用及草莓生长的影响   总被引:1,自引:0,他引:1  
通过液体培养及温室连作草莓土壤修复试验,从自毒物质降解角度研究了4株放线菌对草莓连作障碍的修复作用及对草莓生长的影响。结果表明:在液体培养条件下,7 d后4株供试放线菌对对羟基苯甲酸的降解率达到97.6%~98.7%。同样,在温室连作条件下,4种供试放线菌制剂对草莓根区土壤中的对羟基苯甲酸有明显的降解作用。与对照相比,在草莓种植结束时,251、252、40号菌剂处理的草莓根区土壤中对羟基苯甲酸含量显著下降。供试放线菌接种处理后,草莓根系总重量及新根较对照分别增加28.5%~50.4%及25.7%~80.2%,表明其对草莓根系生长和新根形成有明显促进作用。菌剂还能有效降低草莓植株死亡率和发病率,相对防效达到51.9%~56.3%。但他们对连作温室草莓植株总重量、叶面积及叶片PPO活性影响不明显。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号