首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objectives : The purposes of this study were to determine the prevalence of intravenous catheter colonisation in a routine clinical setting, to identify pathogens involved and to explore factors associated with an increased risk of colonisation. Methods : A prospective study of 100 peripherally placed intravenous catheters from 13 cats and 78 dogs was conducted. The distal two‐thirds were removed and submitted for bacterial and fungal cultures. Antimicrobial susceptibility of each isolate was determined. Results : Nineteen peripheral catheters were positive for microbiologic culture from 14 animals. Twenty organisms were isolated among which Staphylococcus species was the most common. Isolates displayed lower levels of resistance against the antimicrobial agents amoxicillin‐clavulanate, cephalosporins and gentamicin than against other agents tested. Major risk factors predisposing to catheter‐related colonisation included dextrose infusion, duration of catheter placement, local complications and immunosuppressive diseases or drugs. Clinical Significance : In a routine clinical setting, the prevalence of microbial colonisation of peripheral intravenous catheters is comparable to that found in an intensive care unit. However, consequences on morbidity and mortality rates differ.  相似文献   

2.
OBJECTIVE: To determine incidence of and possible risk factors for catheter-associated urinary tract infection (UTI) among dogs hospitalized in an intensive care unit and compare results of bacterial culture of urine samples with results of bacterial culture of catheter tips. DESIGN: Prospective study. ANIMALS: 39 dogs. PROCEDURE: A standard protocol for aseptic catheter placement and maintenance was used. Urine samples were obtained daily and submitted for bacterial culture. When possible, the urinary catheter tip was collected aseptically at the time of catheter removal and submitted for bacterial culture. Bacteria that were obtained were identified and tested for antimicrobial susceptibility. RESULTS: 4 of the 39 (10.3%) dogs developed a UTI. The probability of remaining free from UTI after 1 day in the intensive care unit was 94.9%, and the probability of remaining free from UTI after 4 days was 63.3%. Bacteria isolates were generally common urinary tract pathogens and were susceptible to most antimicrobials. Specific risk factors for catheter-associated UTI, beyond a lack of antimicrobial administration, were not identified. Positive predictive value of bacterial culture of urinary catheter tips was only 25%. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that placement of an indwelling urinary catheter in dogs is associated with a low risk of catheter-associated UTI during the first 3 days after catheter placement, provided that adequate precautions are taken for aseptic catheter placement and maintenance. Results of bacterial culture of urinary catheter tips should not be used to predict whether dogs developed catheter-associated UTI.  相似文献   

3.
Objectives : To prospectively investigate the incidence of mechanical and infectious complications associated with the use of jugular catheters and risk factors for these complications. Methods : Data was collected over a 6-month period and risk factors associated with the occurrence of mechanical or inflammatory complications were investigated. Results : One hundred catheters were placed over a 6-month period, totalling 393 catheter days. Complications were seen in 39% of catheters with a total of 51 complications. Forty-one of these complications were mechanical. A total of 10 inflammatory or infectious complications were identified in eight catheters (a total of 0·03 infectious complications per catheter day). Complications were more likely to occur in patients requiring more than one attempt for placement and patients that were ASA status 3 to 5. Infectious complications were more likely in patients not having general anaesthesia for placement, those having medical rather than surgical disease and those placed out of theatre. No association was found between the skill of the person placing the catheter and risk of complication. Clinical Significance : Mechanical complications are frequently associated with jugular catheter placement. Identification of risk factors for complications is important and warrants further study.  相似文献   

4.
OBJECTIVE: To assess the perioperative and postoperative complications associated with use of vascular access ports (VAPs) in the jugular and lateral saphenous veins of dogs requiring frequent anesthetic episodes for radiation therapy. DESIGN: Cohort study. ANIMALS: 40 dogs referred to a veterinary teaching hospital. PROCEDURES: VAPs were used in 23 dogs, and intravenous catheters inserted in a peripheral vein were used in 17 dogs. The frequency of perioperative and postoperative complications associated with VAP use and the frequency of infection associated with intravenous catheter use were recorded. Results of bacterial culture of VAP tips and amount of time required for VAP placement and removal and for anesthetic induction were also recorded. RESULTS: VAP-associated perioperative complications included malposition of the catheter tip in 4 of 23 (17.4%) dogs. The VAP-associated postoperative complications included seroma formation in 7 (30.4%) dogs, breakage of port-anchoring sutures in 3 (13.0%) dogs, suspected fatal catheter-related septicemia in 1 (4.3%) dog, and temporary partial withdrawal occlusion in 18 of 255 (7.1%) anesthetic episodes. CONCLUSIONS AND CLINICAL RELEVANCE: Placement of VAPs provided ready access in dogs receiving radiation therapy. Most complications were minor and self-limiting; however, a low risk of serious complications existed. Use of fluoroscopy to assess position of the catheter tip is recommended to decrease the risk of malposition. Immediate removal of a VAP is recommended when clinical signs of infection develop. Removal of a VAP at the completion of radiation therapy should be performed unless the benefit of continued vascular access outweighs the risks.  相似文献   

5.
Objective  To evaluate whether equine serum administered via a simulated subpalpebral lavage system (SPL) supports proliferation of Streptococcus zooepidemicus or Pseudomonas aeruginosa within the tubing.
Procedures  A sterile i.v. catheter with injection cap was inserted into sterilized silicone tubing (Mila®). To mimic an SPL within the dorsal conjunctival fornix, the tubing was secured to an elevated platform. The tip of the tubing extended from the platform into a vial containing culture medium just inoculated with approximately 1.5 × 108 CFU/mL P. aeruginosa or S. zooepidemicus . To mimic administration of medication, the tubing was infused twice daily with equine serum, sterile saline (negative control), or culture medium (positive control) followed by air. Incubation was at 25 or 37 °C. At 24, 48, and 72 h postinoculation, samples were obtained for bacterial culture from one simulated SPL for each experimental variant. The following sections were cultured: (i) tubing tip previously submerged in the inoculated culture medium, (ii) tubing mid-section, and (iii) tip of the i.v. catheter. The experiment was performed in triplicate.
Results  Streptococcus zooepidemicus or P. aeruginosa were isolated from 100% of the tubing tips. Streptococcus zooepidemicus was isolated from one mid-section flushed with culture medium incubated at 37 °C. All other samples were negative for growth of the inoculated agents.
Conclusions  Streptococcus zooepidemicus and P. aeruginosa did not proliferate within silicone tubing infused with equine serum. These data suggest that topical serum can be safely administered through a superiorly placed SPL in clinical cases.  相似文献   

6.
The current field study used thoroughbred stallions and mares from central Kentucky to investigate the occurrence of potentially pathogenic bacteria on the stallion's external genitalia, based on cultures, and investigated the occurrence of bacteria and type of isolate in the mare's uterus after breeding by live cover to stallions with or without positive bacterial cultures. Fifteen thoroughbred stallions and 206 mares from two central Kentucky thoroughbred farms were used during the 2010 and 2011 breeding seasons. Samples for bacteriological evaluation were taken from the prepuce and postejaculate urethra (n = 201) of stallions. Uterine swabs (n = 264) were collected 12-18 hours postbreeding. For statistical analyses, a chi-squared test was used to test the relationship between stallion culture results and postbreeding uterine culture results, as well as the effect of bacterial types found on the stallion cultures with bacterial types found on the postbreeding uterine cultures. Of stallion cultures, 22.4% were positive for potentially pathogenic bacteria, with Streptococcus equi subspecies zooepidemicus (51.1%) being the most common isolate. Uterine cultures resulted in a 29.2% positive rate for potentially pathogenic bacteria, with S. equi subsp. zooepidemicus (90.9%) being the most common. There was no difference (P > .05) in the occurrence of bacteria or type of isolate found on uterine cultures after breeding stallions with or without positive cultures. In conclusion, potentially pathogenic bacteria found on the stallion's external genitalia did not affect the occurrence and type of bacterial isolate found in the mare's uterus after breeding by live cover.  相似文献   

7.
Twenty dogs with neoplasms requiring multiple radiation treatments received either percutaneous vascular access catheters (PVACs; Cook, Bloomington, IN) or subcutaneous vascular access ports (SVAPs; Vascular-Access-Ports, Norfolk Medical Products, Inc., Skokie, IL); 10 dogs were entered in each group. All catheters were implanted and removed aseptically and the catheter tips were cultured during implant removal. Complications with PVACs included mild incisional swelling and redness and accidental severance or rupture of the catheter. Complications with SVAPs included incisional or port swelling, bruising or redness, hematoma formation, and pain. Ports in 4 of these dogs could not be used for 1 to 3 days after surgery because of swelling and pain. Surgical wound complications, when pooled for comparison, occurred significantly more frequently with the SVAPs ( P = .023). Wound complications associated with both catheters were self-limiting and resolved within 7 days. Bacterial cultures were positive in two PVACs and four SVAP tips, however, none of these dogs had clinical signs of infection or sepsis. Although both types of indwelling catheters were functional in a clinical setting, PVACs were preferred to SVAPs for dogs undergoing radiation therapy because of decreased time for implantation and fewer overall complications.  相似文献   

8.
OBJECTIVE: To determine the prevalence of bacterial colonization of IV catheters among young dogs suspected to have parvoviral enteritis, to identify the organisms responsible for catheter colonization, and to determine the antimicrobial susceptibility of organisms that were obtained. DESIGN: Case series. ANIMALS: 100 dogs. PROCEDURE: Catheters were aseptically removed when fluid therapy was discontinued, the catheter was replaced, or the dog died. The distal tip of the catheter was cut off, split open, and vortexed with sterile saline (0.9% NaCl) solution. The saline solution was plated on culture plates, which were then incubated and examined for bacterial growth every 24 hours for 72 hours. All bacteria cultured were identified, and antimicrobial susceptibility was determined. RESULTS: Bacteria were isolated from 22 catheters. Most bacteria that were isolated were of gastrointestinal tract or environmental origin (Serratia odorifera, S. liquefaciens, S. marcescens, Acinobacter anitratus, Citrobacter freundii, Klebsiella pneumoniae, K. oxytoca, Escherichia coli, Enterobacter spp). Only 2 gram-positive organisms were isolated (Staphylococcus intermedius and Streptococcus spp). High percentages of organisms were resistant to penicillin, lincomycin, cloxacillin, erythromycin, and cephalexin. Percentages of organisms resistant to amikacin, enrofloxacin, chloramphenicol, potentiated sulfonamides, and amoxicillin-clavulanic acid were low. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that IV catheters may be colonized with bacteria in 22% of young dogs suspected to have parvovirus infection.  相似文献   

9.
Background: It has been suggested that diseases that promote isosthenuria predispose to urinary tract infections because of a lack of the common bacteriostatic properties present in concentrated urine. Objectives: The purpose of this study was to assess the clinicopathologic risk factors for positive urine culture outcome in cats with chronic kidney disease (CKD), diabetes mellitus (DM), uncontrolled hyperthyroidism (HT), or lower urinary tract disease (LUTD). Methods: For this retrospective study, medical records of all cats in which a urinalysis and aerobic bacterial urine culture were performed between January 1995 and December 2002 were reviewed. Signalment, body weight, and clinicopathologic data were recorded. Based on the medical records, cats were diagnosed with CKD, DM, HT, or LUTD. Prevalence odds ratios and 95% confidence intervals were calculated using logistic regression. Multivariate models were created for each variable of interest while controlling for the confounding effect of disease group. Results: Six hundred fourteen cats met the criteria for inclusion in the study. Overall, positive urine cultures were identified in 16.9% of cats with CKD, 13.2% of cats with DM, 21.7% of cats with HT, and 4.9% of cats with clinical signs of LUTD. Decreasing urine specific gravity was not associated with positive urine culture when controlled for disease but pyuria, bacteriuria, and hematuria were all associated with positive urine culture outcome. Persians, females, increasing age, and decreasing body weight were all associated with positive urine culture outcome. Conclusions: Performing a urine culture sample based solely on the presence of isosthenuria does not seem warranted. Further studies are warranted to help identify host predisposing factors for urinary bacterial colonization in cats with these diseases.  相似文献   

10.
The objective of this study was to establish an ultrasound scoring system to assess the degree of fibrin tag and clot formation associated with jugular catheters in horses. A second objective was to test the hypothesis that, in healthy horses undergoing short-term anesthesia, polyurethane (PU) catheters have a different ultrasound score compared with polytetrafluoroethylene (Teflon) catheters. Twenty-three systemically healthy horses requiring anesthesia were randomly assigned PU or Teflon catheters. The mean catheter dwell time was 5 hours. Ultrasound was used to examine the jugular vein before catheter placement, before catheter removal (mean, 4 hours 45 minutes), and approximately 24 hours after catheter insertion (mean, 24 hours 42 minutes). The repeatability of the ultrasound scoring system was assessed by producing a series of randomly ordered selected still images for independent evaluation by four radiologists on two separate occasions. The interobserver and intraobserver repeatability was determined using a weighted kappa statistic, with substantial intraobserver repeatability mean κ .77 (range, .59–.91) and moderate interobserver repeatability mean κ .53 (range, .33–.67). The proportion of positive bacteriologic cultures in the polyurethane (PU) and Teflon groups was compared using Fisher's exact test, with no significant difference (P > .99) between the two groups. The distribution of the scores from the PU and Teflon groups was compared using the Mann-Whitney test, with no evidence of a difference between groups at the time of catheter removal (P = .23) and 24 hours after catheter insertion (P = .20). Further studies with a larger sample of systemically healthy horses are required to substantiate this preliminary finding.  相似文献   

11.
OBJECTIVE: To determine reasons for epidural catheter placement among horses examined at a veterinary teaching hospital, efficacy of epidural administration of analgesics, duration of catheter placement, reasons for catheter removal, and complications encountered. DESIGN: Retrospective study. ANIMALS: 43 horses. PROCEDURE: Medical records were reviewed. RESULTS: A total of 50 epidural catheters were placed in the 43 horses. Underlying conditions included fractures, lacerations, septic arthritis, myositis, perineal injuries, and cellulitis. Horses ranged from 2 to 21 years old and weighed between 365 and 795 kg (803 and 1,749 lb). Median duration of catheter placement was 96 hours (range, 1.5 to 480 hours). The response to epidural drug administration was reported as positive in 34 horses and negative in 4. There was no apparent response in 2 horses, and response could not be determined in 3. Three temporary patient-related complications associated with epidural catheter administration were observed. Technical problems associated with the epidural catheters included dislodgement of the catheter itself (7 catheters) or of the adapter or filter (5), obstruction (5), and leakage (5). Twenty-two catheters were removed because of resolution of the underlying condition, and 10 were removed because of complications. For 6 catheters, the reason for catheter removal was not recorded. The remaining 12 catheters were in place when the horses were euthanatized. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that epidural catheterization can be used successfully for repeated epidural delivery of analgesics and anesthetics in horses with various clinical conditions. Complications associated with epidural catheters or epidural drug administration were infrequent and transient.  相似文献   

12.
Chronic indwelling central vessel catheters provide vascular access for compartmental infusion or sampling. However, complications with catheter patency during the postoperative and/or experimental period often arise. In order to identify physiological occurrences common with such complications, 10 multicatheterized sheep (61.8 +/- 7.8 kg BW), obtained from a previous nutrient flux study were used for gross and histopathological investigation. Catheters had been surgically placed in a hepatic portal vein (PVC), a hepatic vein (HVC), a distal mesenteric vein (MVC) and a mesenteric artery (MAC). In the previous study, catheters (PVC, HVC and MAC) were used to collect blood samples or infuse (MVC) p-aminohippurate. Catheters were maintained for a total of 58 days prior to necropsy. Histopathological findings indicated that catheter failures were associated with the following tissue responses: (i) thromboses with frequent focal vasculitis; (ii) euplastic tissues associated with extensive fibrosis; (iii) granulomas; (iv) neo-vascularization of the media; (v) calcification processes; and (vi) micro-abscesses. Additional studies are needed that address and incorporate improvement of catheter design and placement to minimize irritation of endothelium, improvement of catheter treatments and therapeutic regimes, and development and use of alternative anti-coagulants. A greater understanding of the mechanisms leading to failure will help researchers improve catheter performance and patency.  相似文献   

13.
In studies of Mycobacterium bovis infection in animals a definitive diagnosis requires the isolation of the organism. However, the optimum conditions for the primary isolation of M. bovis have not been determined. The aim of this study was to determine for primary isolation of M. bovis, (a) the incubation time required to achieve maximum sensitivity (i.e., the number of positive samples identified), (b) the effect of decontaminants on bacterial growth rates, and (c) the influence of media and the number of slopes of media on the number of positive samples detected. Two agar-based media, modified Middlebrook 7H11 (7H11) and tuberculosis blood agar (B83), and an egg-based medium, Stonebrink's (SB) were compared. Three decontaminants, 2% (w/v) sodium hydroxide (NaOH), 0.75% (w/v) and 0.075% (w/v) cetylpyridinium chloride (CPC, also called hexadecylpyridinium chloride, HPC) and 0.5% (w/v) benzalkonium chloride (BC) were evaluated against treatment with sterile distilled water. The inoculated media slopes were incubated for up to 15 weeks. Colonies first appeared after 2 weeks on all media types and 75% of positive slopes were identified by 8 weeks. An incubation time of 15 weeks was required to identify all positive samples. The slowest growth was associated with inocula that contained the fewest viable bacilli. The time to the appearance of colonies was influenced by medium type: the median time to detection of colonies was 28 days on 7H11 and B83, and 36 days on SB. However, SB returned the greatest number of positive samples. Decontamination procedures increased the minimum incubation time required to detect positive cultures, probably due to the toxic effect of the decontaminants. Increasing the number of inoculated slopes resulted in an increased number of positive samples and a decreased time to the detection of colonies. Overall, the detection of M. bovis was significantly influenced by the choice of media, the decontaminant and the duration of incubation of cultures.  相似文献   

14.
A one year prospective study was conducted to determine the association between intravenous catheter contamination and increased dwell time, and to identify any related risk factors. Intravenous catheters obtained from 23 cats and 98 dogs in the Intensive Care Unit at the Ontario Veterinary College with dwell times > 72 hours for the test group (n=58) and < 72 hours for a corresponding control group (n=63) were cultured between April 1991 and March 1992. One hundred and twenty one catheters were cultured, 16 jugular, 99 cephalic, and 6 saphenous. The overall contamination rate was 13 out of 121 catheters cultured (10.7%); 9/63 (14.3%) control and 4/58 (6.9%) test catheters. The bacteria isolated were E.aerogenes, S.aureus (3), P.aeruginosa, P.multocida, and Bacillus sp (7). The Bacillus sp positive catheters (5 control and 2 test) were placed during a five day period, and contaminated gauze squares were identified as the source of infection in these catheters. After these were removed from the study, the group infection rate was 6.9% control and 3.6% test. There was no significant difference between groups and no associated risk factors were identified. We conclude that intravenous dwell time need not be restricted to <72 hours.  相似文献   

15.
Simultaneous urethral pressure profilometry using an 8FG polyurethane microtip transducer catheter in the bitch is subject to considerable variation, Marked differences occur in the parameters normally measured due to the orientation of the transducers and patient position. It has been suggested that a softer catheter may result in less variation. In this study, a comparison was made between 8FG polyurethane and silicone rubber microtip transducer catheters in 35 bitches. There were significant variations in both maximum urethral closure pressure and functional profile length due to catheter type (P < 0–001). Resting intravesical pressure varied with the recording transducer (P < 0–001) and there was a significant interaction between catheter type and recording transducer (P < 0–001). Radiographic measurements on 15 bitches suggested that variations in recorded intravesical pressure were probably related to the location of the transducers of the two catheters within the bladder. It is concluded that the use of a softer catheter material alone is insufficient to eliminate variations resulting from the orientation of the recording sensors within the urethra.  相似文献   

16.
Bacterial blood culture results of 292 privately owned cats presented to the Clinic for Small Animal Medicine, Ludwig Maximilian University Munich with signs of sepsis were evaluated retrospectively. Of the blood cultures, 23% were positive. In 88%, a single bacterial species was isolated. Of all bacterial isolates, 45% were Gram-positive, 43% were Gram-negative, and 12% were obligate anaerobes. The most frequently isolated bacteria were Enterobacteriaceae, obligate anaerobic species, Staphylococcus species and Streptococcus species. Of the cats with positive blood cultures, 32% were pretreated with antibiotics. Of all bacterial isolates, 77% were susceptible to enrofloxacin, 69% to chloramphenicol, 67% to gentamicin, and 64% to amoxycillin clavulanic acid. Only enrofloxacin reached an in vitro efficacy of more than 70% against Gram-positive and more than 74% against Gram-negative bacteria.  相似文献   

17.
Of 100 critically ill dogs and cats, 49 (39 dogs, 10 cats) had bacteremia. Gram-negative bacilli were the most common isolates from the bloodstream of dogs with bacteremia (46%), and gram-positive cocci and anaerobic bacteria were isolated from 36% and 31% of positive cultures, respectively; 15% of positive cultures were polymicrobial. In cats, gram-negative bacilli (especially Salmonella enteritidis) and anaerobic bacteria were the most common isolates, and 30% of positive cultures were polymicrobial. Gram-positive cocci were not isolated from the blood-stream of cats. Odds ratios, adjusted for the combined effects of disease status (severe vs nonsevere), results of bacterial culture of blood result (positive vs negative), and species (dog vs cat) were calculated for mortality in animals in the study. In animals with bacteremia, severe disease increased the risk of death 11.6-fold, compared with the risk in animals with nonsevere disease. Bacteremia increased mortality 10-fold in animals with severe disease, compared with mortality in animals with severe disease without bacteremia. Animals with severe disease and bacteremia were 15.6 times more likely to die than were those with nonsevere disease and negative culture results. In animals with nonsevere disease, culture results (positive vs negative) were not related significantly to mortality. Disease status (severe vs nonsevere) in animals without bacteremia also was not significantly related to mortality. There was no significant difference in overall mortality in dogs, compared with that in cats.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
Intravenous catheters are used for the administration of medications and fluids and are an integral part of veterinary practice. The aim of catheter use is to optimise administration of medication and minimise complications such as thrombus formation, thrombophlebitis and sepsis. Catheters made from teflon are less flexible, less durable and stimulate more tissue reaction than polyurethane or silicon. However silicon catheters are more expensive and complicated to insert. Generally, for veterinary practice, the biostability and cost of polyurethane catheters make them preferable for short and long-term use. The smallest diameter catheter should be selected to minimise internal vessel wall contact and irritation without compromising medication delivery. The site of insertion varies with individual preference, vessel access and patient compliance. The jugular, cephalic, saphenous, ear, lateral thoracic and subcutaneous abdominal veins are accessible. Hair removal and a thorough aseptic skin preparation should be performed prior to catheter insertion. Daily maintenance is required to detect complications and maximise catheter longevity. Potential complications include thrombus formation, thromboembolism, bacterial colonisation and septicaemia, blood loss and air embolism. Permanent or transient skin dwelling bacteria are commonly isolated if sepsis occurs. The development of novel antiseptic and antibiotic impregnated catheters may reduce the complications associated with catheter infection in the future.  相似文献   

19.
BACKGROUND: Information is lacking on the prevalence and susceptibility patterns of bacterial isolates in dogs and cats with suspected hepatobiliary disease. OBJECTIVES: To characterize the prevalence, identity, and antimicrobial susceptibility of common hepatobiliary isolates from such patients. ANIMALS: Dogs and cats presented to the University of Wisconsin-Madison Veterinary Medical Teaching Hospital for which samples of bile, gallbladder, or liver were submitted for culture from 1998 to 2003, including 190 dogs (192 culture episodes) and 58 cats (61 culture episodes). METHODS: Cases were identified from the microbiology laboratory database. Data from patient medical records were extracted, including the history of antimicrobial administration, the presence of fever, the results of CBC and serum biochemistry, the presence of biliary obstruction or hepatobiliary inflammation, and the results of aerobic and anaerobic bacterial cultures and aerobic antimicrobial susceptibilities. RESULTS: Biliary cultures yielded a significantly higher percentage of positive results overall (30% [18 of 60]) than did hepatic cultures (7% [15 of 215]). In patients with cholecystitis, 62% (8 of 13) had positive biliary cultures. In patients with hepatic inflammation, 23% (7 of 30) had positive bile cultures, whereas only 6% (6 of 103) had positive hepatic cultures. Escherichia coli, Enterococcus spp., Bacteroides spp., Streptococcus spp., and Clostridium spp. were the most common true-positive isolates. More than 80% of Enterobacteriaceae were susceptible to ciprofloxacin or aminoglycosides, with only 30-67% susceptible to first-generation aminopenicillins and cephalosporins. Liver samples obtained by surgery or laparoscopy were more likely to yield positive cultures than those obtained by percutaneous needle biopsy.  相似文献   

20.
OBJECTIVE: To evaluate complications associated with use of indwelling epidural catheters in dogs in a clinical setting. DESIGN: Retrospective clinical study. ANIMALS: 81 client-owned dogs. PROCEDURE: Medical records were reviewed for dogs in which a 19-gauge epidural catheter was placed percutaneously at L7-S1 and advanced to the point of maximum efficacy for pain control (between L7 and T4, depending on the procedure). Catheters were used to provide perioperative epidural analgesia during surgeries that included perineal (n = 6), hind limb (33), abdominal (43), thoracic (5), forelimb (2), and cervical (1) procedures. RESULTS: Catheters were maintained in situ from 1 to 7 days (mean, 2.3 days; median, 2.0 days). Sixty-four dogs did not have complications; 17 dogs had minor complications. Catheter dislodgement was the most common complication (13/80 [16%] dogs). Catheter site contamination without inflammation developed in 2 (2.4%) dogs; inflammation at the catheter site developed in 2 (2.4%) dogs but was not related to duration of time the catheter was in place. Complications were not serious and did not require treatment other than catheter removal. Dogs that dislodged their catheters were significantly younger (mean, 2.9 years; median, 2.0 years) than other dogs (mean, 6.2 years; median, 6.0 years). Dogs that received femoral fracture repair dislodged their catheters more often (62.5%) than dogs undergoing other procedures (10.9%). CONCLUSIONS AND CLINICAL RELEVANCE: The complication rate associated with temporary epidural catheterization of dogs appears to be low, and complications generally are not serious.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号