首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A nine-week-old labrador was presented with a deformed left forelimb causing obvious lameness. Radiographs suggested that the dog had suffered a fracture involving the radius and ulna which had healed resulting in a synostosis. There was a concurrent radial physeal injury. The dog was treated initially by osteotomy of the radius and ulna stabilised using a static external skeletal fixator. At a subsequent surgery lengthening of the limb was achieved by using an Ilizarov apparatus. Worsening carpal hyperflexion was managed by bandaging in forced extension. A successful outcome was achieved with a final result of a 24 per cent discrepancy in length between the two radii at 17 months of age. An increase in length of the ipsilateral humerus was seen in association with the shortened forelimb.  相似文献   

2.
A 6-month-old female crossbred dog with unilateral radial hemimelia was treated with a circular external fixator. During the first surgery, the dog underwent transverse osteotomy through the distal ulnar physis and rotation of the distal ulnar fragment (epiphysis) together with the forepaw in a lateral direction to achieve contact with the end of the proximal ulnar segment (shaft of the ulna); a circular external fixator was then applied. After removal of the fixator, a cast was applied. The initial intent was to preserve mobility of the ulnocarpal joint; however, the joint fused naturally. A second surgery was performed to lengthen the ulna by use of distraction osteogenesis. An Ilizarov external fixator was used, and the ulna was lengthened 25 mm. During the third surgery, osteotomy of the distal portion of the ulna was performed to treat residual deviation of the forepaw. The surgical treatment resulted in satisfactory use of the limb and a better quality of life.  相似文献   

3.
The use of a 'hybridised' Ilizarov ring fixator is described in the salvage of a septic nonunion of a comminuted tibial fracture with a large diaphyseal cortical sequestrum in an 11-month-old German shepherd dog. A ring fixator assembly incorporating half pin application was chosen to provide flexibility of fixation placement options in limited bonestock which had previously been subject to conventional Kirschner-Ehmer external fixation. Diaphyseal regeneration was achieved by stimulating bone trophism through the axial loading properties of the Ilizarov fixator and the biological osteoinductive properties of cancellous bone autograft. The young age of the dog was considered to make it an optimal candidate for salvage in spite of its highly excitable temperament. Fully functional fracture union with resolution of osteomyelitis was achieved at eight weeks following revision without recourse to intercalary transportation or cortical grafting. Problems with postoperative management of the dog resulted in minor complications and mechanical failure of some of the frame components.  相似文献   

4.
5.
A nine-year-old cat was presented with non-weight-bearing lameness of the right forelimb subsequent to an old fracture of the antebrachium previously treated by external stabilisation. Radiography showed severe atrophic non-union of the distal third of the radius and carpal luxation. Ulnocarpal arthrodesis was performed using a uniplanar external fixator. Follow-up radiography showed that bone fusion was slow but without complication. After 16 weeks, the external fixator was removed, and a Robert-Jones bandage was applied for one month. From postoperative week 2 onwards, the animal progressively made use of the limb in a weight-bearing capacity. At the last examination, one year postoperative, no lameness was observed.  相似文献   

6.
Fractures of the radius and ulna are common in the dog and cat. If treated inappropriately, complications may result. These include delayed union, nonunion, malunion, and growth deformities. ESF is a versatile method of fixation for fractures of the radius and ulna. Types that are applicable range from the simple type I to the complex type III fixator. In general, the more unstable the fracture, the more rigid the assembly must be to counteract fracture forces. There are three basic phases to consider when using ESF: (1) preoperative planning, (2) application of the ESF, and (3) long-term management. A deficiency in any one of these phases can lead to complications and an unsatisfactory clinical outcome. Although ESF can be used on many types of fractures, the technique is especially well suited for open or highly comminuted fractures when internal fixation is not applicable. In these cases, close attention must be paid to the integrity of the soft tissues. In addition, cancellous bone grafts should be placed either at the time of initial repair or in a delayed fashion after adequate vascularity has been established. Staged or complete removal of the ESF should be individualized to each fracture case. In general, staged disassembly or "dynamization" can begin when the bone and fixator begin to function as a composite as determined by radiographs. Complete fixator removal should be considered when the fracture exhibits clinical and radiographic evidences of union.  相似文献   

7.
Objective— To develop instrumentation and a technique for transverse ulnar bone transport osteogenesis in dogs.
Study Design— Cadaveric study and in vivo validation (1 dog).
Sample Population— Paired cadaveric antebrachii (n=10 dogs) and 1 live dog.
Methods— Circular fixator constructs were applied and fitted with reeling or linear motors designed to transport an ulnar segment transversely into a defect created by excising the distal 50% of the ipsilateral radius. A longitudinal osteotomy of the adjacent ulna was created and the segment was transported across the radial defect. Pre- and post-distraction CT scans were used to compare the efficacy of each construct. The procedure was performed unilaterally in a live dog using the reeling motor (RM) construct.
Results— Both constructs effectively transported the ulnar segment into the defect. Subjectively, the RMs were easier to apply and operate. No significant differences were observed in the objective measures of efficacy between the 2 construct types. The live dog produced viable regenerate bone after transverse ulnar bone transport.
Conclusions— Transverse ulnar bone transport should be considered a potential method for limb salvage in dogs with osteosarcoma (OSA) of the distal radius. The RMs were effective and clinically applicable.
Clinical Relevance— Transverse ulnar bone transport osteogenesis affords the benefits of longitudinal radial bone transport osteogenesis, allowing resolution of large longitudinal radial defects in a substantially less time as a result of shortening the transport distance. This would be beneficial when treating conditions such as OSA where minimizing convalescence and maximizing quality of life is a priority.  相似文献   

8.
An 8-week-old female Patagonian cavy was examined because of acute right hind limb lameness; radiography revealed a moderately displaced, comminuted fracture of the proximal third of the tibia. The fracture was stabilized with a hybrid external skeletal fixator. Two Kirschner wires were placed in the main proximal fragment, parallel to the tibial plateau and at right angles to each other. These wires were connected to a partial circular external fixator ring. Three half pins were placed in the distal fragment, and a straight connecting rod positioned on the medial side of the limb was connected to these pins and the fixator ring. A second connecting rod was positioned on the craniomedial side of the limb and was connected to the fixator ring and a fourth half pin in the distal fragment. The fracture healed without complications, and the fixator was removed 3 weeks after surgery. Hybrid external skeletal fixators combine the benefits of circular and linear external skeletal fixation methods, enabling rigid fixation of periarticular long bone fractures without adversely affecting mobility of the adjacent joint.  相似文献   

9.
A four-ring circular external skeletal fixation device was evaluated for transcarpal fixation of compound fractures in two calves. Case 1 was an eight-month-old female Holstein-Friesian x indigenous breed calf weighing 72 kg, which had a Salter-Harris type II fracture at the distal metaphysis of the right radius/ulna with an open contaminated wound on the medial aspect of the carpus. Case 2 was an 18-month-old crossbred Haryana heifer weighing 105 kg, which had a comminuted fracture at the proximal end of its left metacarpus with severe soft tissue trauma and an open wound on the medial aspect. In both cases, the fractures were repaired with four-ring circular fixators by fixing the proximal two rings in the distal radius/ulna and the distal two rings in the metacarpus. Postoperatively, both calves were treated with analgesic and anti-inflammatory drugs and antibiotic, and the pin-bone interfaces and the open wound were cleaned regularly with povidone-iodine solution. In both animals weight bearing was good to excellent in the immediate postoperative period. The fixator was well maintained and tolerated by the animals until the fractures healed after 45 to 60 days. The movement of the carpal joint was slightly affected when the fixator was removed on day 60, but a follow-up examination after one year showed that both calves had normal functional usage of the limbs.  相似文献   

10.
Multiple intramedullary wire fixation infrequently can be used as an alternative technique to plating, transfixation devices, single intramedullary pinning, or external coaptation for some radius and ulna fractures.
This report describes a comminuted fracture of the radius and ulna with fissures and comminution extending too far into the proximal radius for effective application of a bone plate or Kirschner-Ehmer apparatus. Resulting fracture instability and collapse prohibited effective use of external coaptation as a primary means of fixation. The radial fracture was repaired and stabilized with full cerclage wires and multiple intramedullary Kirschner wires. The dog was using the leg normally 12 months following surgery.  相似文献   

11.
OBJECTIVE: To determine treatment and outcome of a series of wapiti (elk) with fractures of the limbs. DESIGN: Retrospective study. ANIMALS: 22 wapiti. PROCEDURE: Medical records were reviewed to determine affected limb and bone, fracture configuration, method of treatment, outcome, and complications. RESULTS: 2 animals had fractures of the humerus; 8 had fractures of the radius, ulna, or both; 5 had fractures of the third metacarpal bone; 3 had fractures of the tibia; 2 had fractures of the femur; and 2 had fractures of the tarsal bones. Most fractures (n = 11) were closed, displaced, nonarticular fractures; 6 fractures were open. Four animals died or were euthanatized prior to fracture treatment, 2 were not treated because fractures had already healed, and 14 underwent fracture repair. In the remaining 2 animals, the affected limb was amputated. Five animals developed nonfatal complications (wound dehiscence, osteomyelitis [2 animals], delayed union, and malunion) and 2 developed fatal complications (gastrocnemius rupture and femoral fracture during recovery). Overall, 16 animals were discharged from the hospital, and all were doing well at follow-up, 2 months to 4 years after discharge. CLINICAL IMPLICATIONS: In wapiti, limb fractures can be successfully treated by means of internal or external fixation. The high rate of fracture healing, even among wapiti with open fractures, should encourage veterinarians to repair limb fractures in wapiti.  相似文献   

12.
The study was undertaken to evaluate the feasibility of a simple, inexpensive model of circular external fixator (CEF) for use in large ruminants. A simple model of CEF frames consisting of four full rings (13-19 cm diameter, 4 cm wide and 4 mm thick with 18-24 holes) connected by threaded rods (8 mm diameter, 10-15 cm long) and nuts was developed using mild (low carbon) steel and were nickel-plated. In the first phase of the study, three male cow calves were utilized to study the feasibility of application of the fixators in the metatarsus, tibia and radius, in reference of adaptation and tolerance by animals. In the second phase, the fixators were tested in osteotomized bones. Six bull calves of 1.5-2 years of age weighing about 200-250 kg were utilized for this purpose. After preparing the area for aseptic surgery, under xylazine (at 0.1 mg/kg, i.m.)-ketamine (i.v. till effect) general anaesthesia, the test bone (metatarsus, radius and tibia in two animals each) was approached through the medial surface and an osteotomy was created with a saw and chisel at the mid-diaphysis. The pre-constructed 4-ring CEF was mounted on the limb around the test bone in such a way that it formed a cylinder with the axis of the limb at the centre. Each ring was then fixed to the bone with a pair of beaded wires (316 SS) of 3.5 mm diameter. During the post-operative period, the animals were observed for any change in behaviour, tolerance of the fixators, the weight bearing on the test limb, the status of the fixator, and the level of reduction of the osteotomy, alignment and healing at different intervals. The fixation of CEF was easier in the metatarsus and radius than in the tibia. The inner ring diameters found adequate for metatarsus, radius and tibia were 13-15 cm, 15-17 cm and 17-19 cm, respectively. The fixators applied to different bones were well-tolerated, and the animals could lay down, stand and walk freely with the fixator without any problems. All the animals showed good weight bearing in the immediate post-operative period. Weight bearing, however, slightly reduced in the inflammatory period and showed improvement after about 4 weeks. Wire tract infection was seen in all the animals, which was more on proximal wire tracts on lateral aspect of limbs. Circular fixators were well-tolerated by all the animals, and there was no breaking/bending of connecting rods, slotted bolts or the rings at any stage of observation. Slight bowing of some wires was noticed in cases of tibia and radius (in phase II) and bending of some wires was noticed from first week in two animals one each in radius and tibia. Bone fragments were well maintained until healing occurred (appearance of bridging periosteal callus) at 60-70 days. The functional results were good in all but one case of tibia, where a mal-union was recorded. From this study, it can be concluded that CEF are well-tolerated by large ruminants and can be used to treat long bone fractures. The fixator assembly using mild steel is sufficiently strong to maintain fracture fixation and is inexpensive. The simple design of the CEF appears to be sufficient to treat simple diaphyseal fractures of the metatarsus and radius. Improvement in the technique of fixation and design-like coupling of linear and circular fixator components into hybrid constructs may help to provide greater rigidity in treating tibial and open long bone fractures.  相似文献   

13.
Radial agenesis was diagnosed in a nine-week-old boxer. An ulnocarpal arthrodesis was performed when six months of age to improve limb alignment and enable weight bearing. When the dog was 10 months old, a hinged circular fixator was applied to the limb to gradually lengthen the ulna and correct angular and rotational deformity. The fixator was removed at 16 months of age. At this time, there was 1·7 cm (6 per cent) shortening of the affected antebrachium-metacarpus and 2·6 cm (15 per cent) compensatory overgrowth of the humerus compared with the contralateral limb. Inability to extend the digits was a complication that improved with physiotherapy. Follow-up at 23 months of age showed good limb use when walking and running. Radiographs of the elbow showed periarticular osteophytes and subcoronoid sclerosis of the ulna.  相似文献   

14.
文章对曾经临床收治诊疗的一例泰迪犬桡尺骨骨折的病例进行总结分析。患犬就诊时精神尚可,经过触诊和DR检查见右前肢遭到破坏、发生断裂,因此采取骨板内固定对桡尺骨完全断裂的患犬进行整复,内固定后利用DR诊断技术对桡尺骨的愈合情况作一系列评估。经过治疗,患犬愈后良好。文章为临床上犬桡尺骨骨折相关的诊疗提供参考。  相似文献   

15.
Repair of a comminuted fracture of the proximal portion of the radius and ulna in a 4-month-old llama was achieved by use of internal fixation. An 8-hole narrow dynamic compression plate was applied to the lateral aspect of the radius and a 7-hole narrow dynamic compression plate was applied to the cranial aspect of the radius. One year after surgery, the llama had a normal gait and the cosmetic appearance of the limb was excellent.  相似文献   

16.
Repair of a comminuted, spiral oblique, proximal diaphyseal femoral fracture in a 7-day-old calf was achieved by use of an intramedullary pin, cerclage wires, and external fixator. Six stainless steel wires were used for full cerclage to secure a long butterfly fragment and multiple incomplete and complete nondisplaced fragments to the femur in order to create 2 principal fragments. Axial alignment and resistance to bending was provided by a round, double-pointed, end-threaded intramedullary pin (6.35 mm in diameter), which was inserted in a retrograde fashion. A type-1, double-connecting-bar external fixator, using 4 round pins (4.8 mm in diameter), was used to provide supplemental stabilization against shear and torsional forces. At 45 days after surgery, healing at the fracture site was seen on radiography of the limb, and the external fixator was removed. Eight months after surgery, the calf had a normal gait.  相似文献   

17.
A six-month-old male golden retriever was presented with a shortened radius and ulna and valgus deformity of the carpus secondary to premature closure of the distal radial and ulnar physes. Osteotomies of the radius and ulna were performed and the antebrachium was lengthened over eight weeks using a Wagner apparatus. This external fixation distractor is used in humans for limb-lengthening procedures. In this case, it was used to correct the angular deformity and to lengthen the limb.  相似文献   

18.
The aim of this study was to clinically and radiographically evaluate acute bone shortening followed by gradual lengthening in the treatment of large segmental tibia defects induced in seven clinically normal dogs. A circular external fixator was assembled with one proximal 5/8-circle ring, one middle ring and one distal ring connected with three rods. Thirty per cent of the tibia and fibula were removed in the middle and distal parts of the diaphyses, between the middle and distal rings. Acute bone shortening with compression of proximal and distal segments was performed. A subperiosteal osteotomy was performed between the half-ring and middle ring. Bone distraction started 7 days after surgery; after lengthening, the apparatus was left in place for 14 weeks for consolidation of regenerated bone. The frame was removed at the end of this period, and the dogs observed for four more weeks. Functional results were considered excellent in two, good in three and fair in the other two dogs. Bone regeneration within the distraction gap was obtained 14 weeks after neutral fixation period. We concluded that acute bone shortening followed by gradual lengthening by Ilizarov method can be used to treat extensive tibial defects in dogs, although it presents limb temporary abnormal limb shape and unequal length as early disadvantages.  相似文献   

19.
Two male intact dwarf rabbits (Oryctolagus cuniculus), 20 and 26 months old, were diagnosed with traumatic long bone fractures of the radius/ulna and tibia, respectively. Transfixation pin splinting, a technique adapted from large animal orthopedics, was used to stabilize the long bone fractures in both rabbits. Bony union with return to normal limb function was achieved in both cases within 6 weeks. The 2 cases were followed for up to 14 months after surgery, and each patient's affected leg returned to normal function. Transfixation pin splints can provide a safe and effective alternative to traditional small animal fracture repairs in domestic rabbits.  相似文献   

20.
External skeletal fixation is a very useful technique for managing many orthopedic problems in veterinary practice. The Kirschner apparatus has been the most widely used fixator for many years in veterinary orthopedics because of its versatility, simplicity, and economy in use. The medium-sized device has the widest indications and is easiest to begin with. The small size can be acquired later for use on cats and small dogs. The new "raised thread" fixation pin designs improve bone-pin integrity and can be used in combination with nonthreaded pins to decrease the incidence of postoperative complications and for economy. Acrylic-pin external fixators are particularly useful for treatment of mandibular fractures and transarticular application since they allow nonlinear placement of fixation pins in highly contoured bones. A commercial system, currently being developed, will have all the equipment and materials necessary for their application in a convenient kit. Circular fixators (Ilizarov design) use thin K wires placed under tension to replace rigid fixation pins. Their unique adjustability characteristics make them useful in the treatment of limb deformity and shortening. Many other human fixators can be used for veterinary application if the basic principles of fixators are followed. Instrumentation required for external fixator application include a pin driver, pin cutter, and wrenches. Although surgical versions of these materials are available, less expensive alternatives are available using gas sterilization instead of autoclaving. The use of selected orthopedic instrumentation such as a periosteal elevator, bone clamps, and curets will facilitate fracture management.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号