首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 388 毫秒
1.
Gregory B.  Daniel  DVM  MS  Ronald  Bright DVM  MS  Eric  Monnet  DVM  Paul  Ollis  RT 《Veterinary radiology & ultrasound》1990,31(4):175-181
Per-rectal portal scintigraphy using tech-netium-99m pertechnetate (99mTcO4-) was performed in 8 normal dogs before and after surgical creation of a portacaval shunt. Shunt fractions were calculated by computer assisted analysis of dynamic images (IMG) and compared to shunt fractions determined by mesenteric venous injection of radioactive microspheres (MIC). The mean pre-operative shunt fraction was 1.59% using IMG and 3.00% using MCI. The mean postoperative shunt fraction was 64.56% using IMG and 69.56% using MIC. There was excellent correlation between both methods (r2 0.94). Per-rectal portal scintigraphy is an easily performed, inexpensive method to diagnose and quantify portosystemic shunts in dogs.  相似文献   

2.
Philip D.  Koblik  DVM  MA  Chi-K  Yen  MD  William J.  Hornof  DVM  MS  Pamela  Whiting  DVM  Paul  Fisher  BS 《Veterinary radiology & ultrasound》1989,30(2):67-73
Transcolonic 123I-Iodoamphetamine is rapidly absorbed across the colonic mucosa and binds to amine receptors in the liver and lungs. During the first ten minutes following colonic administration, a simple ratio of lung counts to lung counts plus liver counts provides an accurate estimate of the fraction of portal blood that bypasses hepatic sinusoids in dogs with portosystemic shunts. Studies were performed on 24 dogs with suspect portosystemic shunt. Shunt fraction values for 18 dogs with surgically confirmed portosystemic shunt were obviously higher than published values for normal dogs, and also significantly higher than values for the other six dogs, later confirmed to lack shunts. Postoperative studies were repeated on ten dogs with single shunt vessels 1–2 days after shunt closure. Total shunt ligation resulted in normal postoperative shunt fraction, whereas partial shunt ligation resulted in persistant elevation of shunt fraction. Transcolonic iodoamphetamine scintigraphy is noninvasive, easy to perform, and provides an accurate method to diagnose dogs with portosystemic shunt.  相似文献   

3.
Per rectal portal scintigraphy using 99mTechnetium pertechnetate (99mTcO4-) was used to diagnose portosystemic shunts (PSS) before surgical confirmation in seven dogs and two cats. Shunt fractions, representing the percent of portal blood that bypasses the liver, were determined by computer analysis of the scintigraphic images. Animals with portosystemic shunts had a mean preoperative shunt fraction of 84.02% (n = 9). The mean postoperative shunt fraction in four animals was 58.22%. The mean shunt fraction in ten control dogs was 5.00%. Per rectal portal scintigraphy is an innovative, easily performed, inexpensive method to diagnose congenital portosystemic shunts in dogs and cats.  相似文献   

4.
Seven dogs with thyroid gland carcinoma were treated with 131I and hormone suppressive therapy either alone (3 dogs) or in combination with surgery (3 dogs) or 137Cs teletherapy and chemotherapy (1 dog). Empirically chosen doses of 75 to 137 mCi of 131I were given orally (2 dogs) and intravenously (5 dogs). Adverse effects were limited to acute, transient bone marrow hypoplasia and pancytopenia. Nominal objective reduction in tumor volume or size and number of pulmonary metastases was observed in 4 dogs treated with 131I and thyroxine. Of these 4 dogs, 2 had stable disease for periods of 4 and 12 months while a third dog had stable disease for 27 months following two 131I treatments at 3 month intervals. The fourth dog had progressive disease. Two dogs with mediastinal metastases showed reduction in localization of 99mTc pertechnetate and radioiodine following 2 and 3 treatments using 131I. It appears that relatively high doses of 131I can be used safely for the treatment of canine thyroid tumors and that further investigation can be justified to define its efficacy.  相似文献   

5.
Diagnosing right-to-left congenital cardiac shunts can be difficult. Cardiac catheterization and angiocardiography represent the traditional gold standard for diagnosis, but they are invasive. Nuclear scintigraphy using 99mTc-macroaggregated albumin (MAA) has been employed in humans as an alternate method of diagnosis. This study reviews eight dogs presented for evaluation of a suspect right-to-left cardiac shunt that were examined using 99mTc-MAA. In all, 2-4 mCi (74-148 MBq) of reduced particle 99mTc-MAA were injected IV in a cephalic vein and static images of the whole body, including right and left lateral, dorsal, and ventral views, were acquired for 60 s and stored into a 256 x 256 x 16 matrix. Shunt fractions were calculated. One dog with radiopharmaceutical distribution limited to the lungs did not have a shunt. Seven dogs had distribution of the radiopharmaceutical outside the pulmonary capillary bed, indicating bypassing of the pulmonary capillary circulation due to a right-to-left shunt. Four dogs had 99mTc-MAA within the brain. Three dogs that did not have brain uptake, but instead had a sharp cutoff of radioactivity at the level of the front limbs and neck, were diagnosed with reverse patent ductus arteriosus (PDA). The asymmetric distribution of the radiopharmaceutical is due to the location of the shunt, distal to the brachiocephalic trunk and left subclavian artery. Shunt fractions of dogs with extrapulmonary radioactivity ranged from 40% to 59%. Nuclear scintigraphy with 99mTc-MAA is a quick alternative method of diagnosing right-to-left cardiac shunts that permits quantification of shunt fraction. Distinguishing between reverse PDA and other right-to-left shunts may be possible based on the radiopharmaceutical distribution.  相似文献   

6.
Positron emission tomography (PET) has found widespread application for staging and monitoring neoplastic diseases in humans. PET is becoming more available in veterinary medicine, therefore biodistribution of 2-deoxy-2-[18F]fluoro- d -glucose (18FDG) in normal dogs is needed for lesion interpretation in disease states. A large field-of-view (FOV) PET scanner with a 70 cm bore diameter and a 53-cm FOV was used in this study to acquire dynamic 18FDG uptake data from parenchymal organs in seven normal dogs. A 2-h, dynamic list-mode acquisition was initiated simultaneously with intravenous 18FDG injection. Regions of interest (ROIs) were manually drawn over liver, spleen, left and right renal cortices, left ventricular free wall, and thymus. Standardized uptake values (SUVs) of these organs were calculated for 24 5-min frames over the 2-h acquisition. This SUV data from parenchymal organs of normal dogs compares favorably with those of normal humans and will be used in ongoing canine studies using PET to evaluate various diseases.  相似文献   

7.
Positron Emission Tomography (PET) using the glucose analog 2-deoxy-2-[18F]fluoro- d -glucose (18FDG) is a common imaging modality for diagnosis and management of many human malignancies. We evaluated 18FDG-PET in dogs with either multicentric lymphoma (LSA) or cutaneous mast cell tumor (MCT). A prototype large field-of-view PET scanner was used to collect whole-body images in nine dogs with LSA or MCT. Both tumors were characterized by avidity for 18FDG. In dogs with LSA, 18FDG-PET correctly identified involvement of superficial and internal lymph nodes, liver, and spleen. Repeated PET scans after induction chemotherapy demonstrated resolution of abnormal 18FDG uptake within these sites. In dogs with MCT, 18FDG-PET correctly identified MCT metastasis to regional lymph nodes in all dogs in which this was suspected or confirmed with cytology or biopsy before the PET scan. In two dogs, additional sites of mast cell disease were identified with 18FDG-PET that were undetected on physical examination and/or regional lymph node cytology. 18FDG-PET holds promise as a whole-body staging method for canine LSA and MCT.  相似文献   

8.
Positron emission tomography (PET) with 2-deoxy-2-[18F]fluoro- d -glucose (18FDG) is an important imaging modality for diagnosis and staging of human neoplastic disease. The purpose of this study is to describe the normal 18FDG uptake in adult cats. Six adult healthy female cats were used. Cats were sedated and then injected intravenously with 74.0±13.0 (mean±SD) MBq of 18FDG. General anesthesia was induced and cats were placed in ventral recumbancy on the PET scanner's bed. Static images using multiple bed positions were acquired approximately 60–90 min after injection. A transmission scan was acquired at each bed position utilizing a 57Co point source to perform attenuation and scatter correction. Regions of interest (ROIs) were drawn over the liver, right and left renal cortices, left ventricular wall, and wall of ascending and descending colonic segments. Standardized uptake values (SUV) were calculated using an established formula. Kidneys and intestinal tract had relatively intense uptake of 18FDG; liver activity was intermediate; the spleen was not identified in any of the cats. Cardiac activity was variable but intense activity was noted in the left ventricular myocardium in most cats. No appreciable lung uptake was noted. Mean±SD SUV values were calculated. This study established the normal pattern of uptake of 18FDG in adult cats and provided baseline data for comparison with future studies evaluating a variety of neoplastic and nonneoplastic diseases.  相似文献   

9.
The purpose of this sutdy was to determine the clinical utility of 111 In-labeled transferrin ( 111 In-TF) scintigraphy for evaluating dogs suspected of having protein-losing enteropathies. Four dogs were injected intravenoulsy with autologous 111In-TF after 30 min incubation (at 37°C) of 18.5 MBq (0.5mCi) 111In CI3 with one ml of autologous plasma, Serial right lateral, left lateral and dorsal images were obtained 2, 4, and 24 hours post 111 In-TF administration, Images were subjectively evaluated for the presence or absence of 111 within the gastrointestinal tract. The results of total protein, albumin and globulin legels and results form gastrointestinal tract. the results of total protein, albumin and globulin levels and results from gastrointestinal biopsies were recorded. In one dog, a follow-up scientigraphic study was done six months after initial evaluation and initiation of treatment for plasmocytic-lymphocytic enteritis. Gastrointestinal activity was noted by two hours in two dogs, while all four dogs had gastrointestinal activity on the 24 hour images. The mean (±std dev) plasma protein, albumin and globulin levels were 3.5 (±0.9), 1.7 (±1) and 1.8 (±0.3) respectively at the time of initial presentation. In the one dog that was evaluated after therapy, faint visualization of radioactivity within the colon was noted on the 24 hour image. Based on this study, 111In-TF appears to be a viable scientigraphic method for evaluating dogs with suspected dogs withfd suspected protein-losing enteropathies, Potential limitations of tjis radiopharmaceutical include cost and prolonged isolation of the animal prior to release to the client due to the long physical half-life (T½= 2.82 days).  相似文献   

10.
Quantitative hepatobiliary scintigraphy using 99mTc-2,6 diisopropylphenylcarbamoylmethyl iminodiacetic acid (DISIDA) was performed in normal dogs. 99mTc-DISIDA is excreted by the hepatocyte into the biliary tract. Hepatic blood flow from arterial and portal venous sources was measured as the hepatic perfusion index. The hepatic clearance of the radiopharmaceutical was used to assess hepatocyte function and parenchymal biliary transport. Biliary ejection was evaluated using synthetic cholecystokinin infusion. The procedure should be useful in evaluating dogs with hepatic and biliary disease.  相似文献   

11.
The aims of this study were to determine if accurate diagnosis of congenital portosystemic shunt was possible using two dimensional, grey-scale ultrasonography, duplex-Doppler, and color-flow Doppler ultrasonography in combination, and to determine if dogs with congenital portosystemic shunts have increased or variable mean portal blood flow velocity. Eighty-two dogs with clinical and/or clinicopathologic signs compatible with portosystemic shunting were examined prospectively. Diagnosis of congenital portosystemic shunt was subsequently confirmed in 38 of these dogs using operative mesenteric portography: 14(37%) dogs had an intrahepatic shunt and 24(63%) had an extrahepatic shunt. Ultrasonography had a sensitivity of 95%, specificity of 98%, and accuracy of 94%. Ultrasonographic signs in dogs with congenital portosystemic shunts included small liver, reduced visibility of intrahepatic portal vessels, and anomalous blood vessel draining into the caudal vena cava. Correct determination of intra - versus extrahepatic shunt was made ultrasonographically in 35/38 (92%) dogs. Increased and/or variable portal blood flow velocity was present in 21/30 (70%) dogs with congenital portosystemic shunts. In one dog with an intrahepatic shunt the ultrasonographic diagnosis was based partly on finding increased mean portal blood flow velocity because the shunting vessel was not visible. Detection of the shunting vessel and placement of duplex-Doppler sample volumes were facilitated by use of color-flow Doppler. Two-dimensional, grey-scale ultrasonography alone is sufficient to detect most intrahepatic and extrahepatic shunts; sensitivity is increased by additional use of duplex-Doppler and color-flow Doppler. Increased and/or variable portal blood flow velocity occurs in the majority of dogs with congenital portosystemic shunts.  相似文献   

12.
Background: Chronic kidney failure is frequently seen in middle-aged and elderly cats. 51Chromium-ethylene diaminic tetraacetic acid (51Cr-EDTA) clearance and single blood sample (SBS) method are used in several species to estimate the glomerular filtration rate (GFR).
Hypothesis: The hypothesis of this study was that 51Cr-EDTA clearance could be determined using an SBS method in normal and hyperthyroid cats.
Animals: Forty-six cats were included in this study, with an average age of 9.5 years. Of these cats, 27 had hyperthyroidism; 19 were healthy.
Methods: After IV injection of 51Cr-EDTA (average dose: 4.25 MBq), 7 blood samples were obtained between 5 and 240 minutes. Reference clearance was calculated in mL/min and mL/min/kg body weight, using a 2-compartment model. Optimal time for clearance measurement with SBS was then determined by systematically comparing each individual plasma concentration to the reference multisample clearance.
Results: The average reference plasma clearance of 51Cr-EDTA for all cats was 14.9 mL/min (3.7 mL/min/kg). The clearance in hyperthyroid cats averaged 16.4 mL/min (4.3 mL/min/kg) and in normal cats averaged 10.3 mL/min (2.4 mL/min/kg).
The optimal time for the SBS was 48 minutes after injection of tracer 51Cr-EDTA ( R 2= 0.9414), giving the following converting equation: clearance = (0.0066 × DV48 minutes) – 0.9277 (in mL/min).
Conclusions and Clinical Importance: In this study, the single sample 51Cr-EDTA clearance method was used to estimate the global GFR in cats. The method identified differences in clearance between normal and hyperthyroid cats. The optimal time for an SBS was 48 minutes.  相似文献   

13.
A novel surgical approach, using portal venotomy during total hepatic vascular occlusion, was used to locate and attenuate congenital intrahepatic portosystemic shunts in nine dogs. Shunt location was consistent with a persistent ductus venosus in only two dogs. In the remaining seven dogs the shunts were window-like orifices arising from either the left (two dogs) or right portal vein branch (five dogs) and communicating with the ipsilateral hepatic vein or caudal vena cava. The transportal approach using total hepatic vascular occlusion consistently provided good access to the portosystemic shunts, including those with window-like communications. A 7 to 16 minute period of total vascular occlusion was well-tolerated hemodynamically, with few intraoperative complications. Intrahepatic shunts were successfully attenuated in eight dogs, while one dog with portal atresia was euthanatized. The postoperative course was complicated by high protein pulmonary edema (one dog), an encapsulated biliary pseudocyst (one dog) and uncontrollable hemorrhage caused by an uncharacterized coagulopathy (one dog). Three dogs required a second operation to further attenuate their shunts. The clinical condition of all seven surviving dogs was improved after surgery.  相似文献   

14.
Technetium-99m methoxy-isobutyl-isonitrile (sestamibi) imaging of malignant canine lymphoma was performed in thirteen dogs 1 hour after intravenous injection of 99mTc-sestamibi at 13 MBq (0.35 mCi) per kilogram body weight. Abnormal tracer uptake was visualized in the liver, spleen, bone marrow, and mesenteric, inguinal, popliteal, sternal, cranial cervical and mandibular lymph nodes. Radiopharmaceutical uptake was also noted in a nasal mass. One large neoplastic renal mass did not have demonstrable sestamibi uptake. Other regions had no significant difference in the target:background ratios when compared with values from normal dogs ( P > 0.05). 99mTc-sestamibi can be used to image malignant lymphoma, and has potential applications in the management of patients to document response to treatment and to stage of extent of disease.  相似文献   

15.
Quantitative hepatic scintigraphy is a valid means for estimating total liver blood flow and relative portal hepatic perfusion. The Hepatic perfusion index (HPI) was determined for a group of 12 dogs with portosystemic shunts prior to and two days after corrective surgery. HPI values for the dogs prior to operation were significantly elevated (p<0.001) as compared with those for a group of normal dogs, indicating reduced effective portal hepatic perfusion in dogs with shunts. Dogs showing a favorable clinical response after surgery had a significant decrease (p<0.02) in HPI values after operation. One dog showing a poor clinical response after operation had an increase in HPI score after operation. Quantitative hepatic scintigraphy is a valuable diagnostic test for screening presumptive cases of portosystemic shunts and monitoring the response to surgical intervention.  相似文献   

16.
SUMMARY: Post-prandial serum bile acid concentrations were measured in 200 Maltese dogs in an attempt to identify those with subclinical portosystemic shunts. Five of these were later shown to have hepatic pathology or abnormal liver function. In the other 195 Maltese bile acid concentrations ranged from 1 to 362 μmol.L-1 (mean ± SD, 70 ±50 μmol.L-1; median, 65.0 μmol.L-1). Of these, 79% were above the reference range (0 to 31 μmol.L-1) established from 23 mixed-breed control dogs. It was therefore not possible to determine the prevalence of subclinical portosystemic shunts on the basis of bile acid determinations.
Further investigation of liver function was performed to investigate why bile acid concentrations were increased in these dogs. Rectal ammonia tolerance tests were normal in 102 of 106 Maltese tested and liver samples (11 dogs) and plasma biochemistry profiles (9 dogs) demonstrated no significant hepatic disease or dysfunction.
Of 2 Maltese with hyperammonaemia after administration of ammonium chloride, one had a large congenital portosystemic shunt that was confirmed at surgery. In the other there were no macroscopic portosystemic communications, but a liver biopsy showed histological changes consistent with microscopic portovascular dysplasia.
Total serum bile acid concentrations were consistently lower when assessed by highperformance liquid chromatography than by an enzymatic spectrophotometric method. This discrepancy was substantially larger in Maltese than in control dogs, suggesting the presence of an additional reacting substance in the serum of Maltese dogs.  相似文献   

17.
Ultrasound-guided percutaneous trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-) has been used to image the portal venous system in normal dogs. Compared with per-rectal portal scintigraphy, it provides higher count density, consistent nuclear venograms of the splenic and portal vein, and significantly decreased radiation exposures. This paper describes the use of TSPS for the diagnosis of portosystemic shunts in 28 dogs. TSPS was performed injecting 70 +/- 28 MBq of 99mTcO4(-) (mean +/- SD) into the splenic parenchyma with ultrasound guidance. A dynamic acquisition at a frame rate of four frames/s for 5 min was initiated after placement of the needle and approximately 2s prior to injection. All dogs had diagnoses confirmed via exploratory laparotomy or ultrasonographic identification of the shunting vessel(s). Three studies (10.7%) were nondiagnostic because of intraperitoneal rather than intrasplenic injection of the radionuclide. Three pathways were recognized on the scintigraphic images: (1) portoazygos shunts--the 99mTcO4(-) bolus traveled dorsally, running parallel to the spine and entering the heart craniodorsally; (2) single portocaval or splenocaval shunts--the 99mTcO4(-) bolus ran from the area of the portal vein/splenic vein junction in a linear fashion toward the caudal vena cava entering the heart caudally; (3) internal thoracic shunt-the 99mTcO4 bolus traveled ventrally along the thorax and abdomen entering the cranial aspect of the heart. Single and multiple shunts were easily distinguished. There were no distinguishing features between single intra and extrahepatic portocaval shunts.  相似文献   

18.
Technetium-99m hexamethylpropyleneamine oxine (99mTc-HMPAO) and Indium-111 oxine (111In-oxine) labeled canine gramulocytes were evaluated in vitro over a six hour period. Labeling efficiency for 99mTC-HMPAO and 111In-oxine labeled granulocytes was 39.6%± 8.0% and 60.6%± 17.6% (mean ± SD) respectively. The mean in vitro elution of the radiolabel ranged from 8.7-14.0% for the 99mTc-HMPAO grannulocytes and from 6.1-9.0% for the 111In-oxine granulocytes. Mean cell viability, for the 99mTc-HMPAO, 111In-oxine and non-radiolabeled control granulocytes ranged from 97.8-99.4%, 96.4-98.5% and 98.2-99.0%, respectively. The phagocytic ability of the 99mTc-HMPAO, 111In-oxine and control granulocytes ranged from 47.5-54.1%, 38.9-56.2% and 46.6-57.8% respectively over the six hour study period. Although labeling efficiency using 111In-oxine was significantly (P=0.05) better than 99mTc-HMPAO, there was no significant difference in label retention of the two radiolabels. There was no significant difference in viability or phagocytic function during the six hour study period. Considering the potential cost advantage and the superior imaging qualities of Technetium-99m relative to Indium-111, 99mTc-HMPAO appears to be a good alternative to 111In-oxine as a granulocyte label.  相似文献   

19.
OBJECTIVE: To evaluate the efficacy of cellophane banding of single congenital extrahepatic portosystemic shunts in dogs using transcolonic portal scintigraphy. To investigate the portal circulation of those dogs with elevated postoperative shunt fractions to determine the cause of the persistent shunting. Further, to evaluate whether presenting signs, clinical pathology findings and liver histopathology are predictive of outcome. DESIGN: Prospective study of 16 dogs presenting with single congenital extrahepatic portosystemic shunts. PROCEDURE: Dogs with single extrahepatic portosystemic shunts attenuated by cellophane banding underwent portal scintigraphy and bile acids tolerance testing pre- and post-operatively. Dogs identified with elevated shunt fractions at 10 weeks post-operatively underwent mesenteric portovenography. Qualitative hepatic histopathology from all dogs was reviewed by a veterinary pathologist and assigned a semi-quantitative score to identify any abnormalities that may predict surgical outcome. RESULTS: At 10 weeks post cellophane banding, 10 of 16 cases (63%) had normal shunt fractions, whilst six dogs (37%) had increased shunt fractions and seven dogs (44%) had increased serum bile acids. Of these dogs, mesenteric portovenography revealed incomplete closure of the shunt in three dogs (18.6%) and multiple acquired shunts in three dogs (18.6%). Liver histopathology findings were similar for all dogs, regardless of outcome. CONCLUSIONS: Cellophane banding is an efficacious method for complete gradual occlusion of single extrahepatic shunts when the shunt vessel is attenuated to < or = 3 mm. Transcolonic portal scintigraphy is a reliable method for assessment of shunt attenuation and, unlike serum bile acids, is not influenced by other causes of liver dysfunction.  相似文献   

20.
The purpose of this study was to evaluate nonuniform patterns of vascular distribution of pertechnetate in the dog during per-rectal portal scintigraphy. Ninety-two studies were reviewed retrospectively to document the patterns of radionuclide distribution. Forty-five studies were classified as normal and 47 were classified as diagnostic for a macrovascular portosystemic shunt. In these dogs, shunt fractions were calculated and compared using a t-test. In dogs with sufficient liver radioactivity for evaluation, the study was classified as having uniform, dorsal, central, or ventral radiopharmaceutical distributions. There were 51 animals (45 normal and six dogs with low-magnitude portosystemic shunts) with sufficient liver activity to assess the radionuclide distribution within the liver. A one-way ANOVA was used to compare shunt fractions between each of the distribution patterns. Two dogs were anesthetized and selective portovenograms were performed. Portovenograms were compared with the scintigraphic images to correlate the vascular distribution of the right, central, and left divisional branches of the portal vein. The shunt fraction in the 45 normal dogs was significantly lower than in the dogs with portosystemic shunts (5.7% +/- 4.8% vs. 78.6% +/- 20.0% (mean +/- SD), P < 0.001). Of the 51 dogs with sufficient liver activity to classify the pattern of distribution, there were 15/51 (31.4%) with uniform radionuclide distribution, 10/51 (19.6%) with focal dorsal distribution, 15/51 (29.4%) with focal ventral distribution, and 10/51 (19.6%) with focal central distribution. There was no significant difference in the shunt fractions between the groups. There were six dogs diagnosed with low-magnitude portosystemic shunt with sufficient liver radioactivity to categorize the vascular distribution of the radionuclide within the liver. Of these six dogs, two had focal dorsal distribution, one had focal central, one had focal ventral and two had uniform distribution. Focal dorsal distribution could result from streamlining of the radionuclide into the right divisional branch of the portal vein. Focal ventral distribution could result from streamlining the radionuclide into the left divisional branch of the portal vein. Focal central distribution could result from streamlining the radionuclide into the central divisional branch of the portal vein.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号