首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Magnetic resonance (MR) imaging of the canine brain is commonly acquired at field strengths ranging from 0.2 to 1.5 T. Our purpose was to compare the MR image quality of the canine brain acquired at 3 vs. 7 T in dogs. Low‐resolution turbo spin echo (TSE) T2‐weighted images (T2W) were obtained in transverse, dorsal, and sagittal planes, and high‐resolution TSE T2W and turbo spin echo proton density‐weighted images were obtained in the transverse and dorsal planes, at both 3 and 7 T. Three experienced reviewers evaluated 32 predetermined brain structures independently and without knowledge of field strength for spatial resolution and contrast. Overall image quality and evidence of artifacts were also evaluated. Contrast of gray and white matter was assessed quantitatively by measuring signal intensity in regions of interest for transverse plane images for the three pulse sequences obtained. Overall, 19 of the 32 neuroanatomic structures had comparable spatial resolution and contrast at both field strengths. The overall image quality for low‐resolution T2W images was comparable at 3 and 7 T. High‐resolution T2W was characterized by superior image quality at 3 vs. 7 T. Magnetic susceptibility and chemical shift artifacts were slightly more noticeable at 7 T. MR imaging at 3 and at 7 T provides high spatial resolution and contrast images of the canine brain. The use of 3 and 7 T MR imaging may assist in the elucidation of the pathogenesis of brain disorders, such as epilepsy.  相似文献   

2.
The magnetic resonance (MR) imaging features of the normal canine thyroid gland were retrospectively compiled from images acquired in 44 dogs presented for a variety of diseases unrelated to the thyroid gland. The appearance of the thyroid gland on different sequences, including pre- and postcontrast T1-weighted, T2-weighted, two-dimensional gradient echo, three-dimensional T2*-weighted gradient echo and proton density weighted images, were described in different image planes. The characteristic shape, location, and intensity of thyroid lobes compared with surrounding structures made them easily detectable in all dogs. The most common location of the thyroid lobes was dorsolateral to the trachea with the maximal cross-sectional area of the lobes located ventral to C2/3 or C3 in more than 85% of the dogs. The majority of the lobes were ovoid on transverse images. An isthmus was seen in one large dog and parathyroid glands could not be seen. The mean maximal thyroid lobe diameter on transverse images was 8.1 mm, being twice the mean diameter of the common carotid artery. Considering the excellent conspicuity and characteristic appearance of the canine thyroid gland, MR imaging can be beneficial in the diagnosis of diffuse thyroid diseases, in differentiating thyroid vs. nonthyroid neck masses and in staging and treatment planning of thyroid tumors in this species.  相似文献   

3.
Alberto  Arencibia  DVM  PhD  Jose M.  Vazquez  DVM  PhD  Juan A.  Ramirez  MD  PhD  Gregorio  Ramirez  DVM  PhD  Jose M.  Vilar  DVM  Miguel A.  Rivero  DVM  Santiago  Alayon  MD  Francisco  Gil  DVM  PhD 《Veterinary radiology & ultrasound》2001,42(5):405-408
The purpose of this investigation was to define the magnetic resonance (MR) imaging appearance of the brain and associated structures of the equine head. MR images were acquired in oblique dorsal (T2-weighted), sagittal (T1-weighted), and transverse planes (T2-weighted), using a magnet of 1.5 Tesla and a human body coil. Relevant anatomic structures were identified and labeled at each level. The resulting images provided excellent anatomic detail of the cranioencephalic structures. Annotated MR images from this study are intended as a reference for clinical imaging studies of the equine head, specially in the diagnosis of brain diseases in the horse.  相似文献   

4.
Magnetic resonance imaging was conducted on previously frozen left carpi from six normal dogs using a 1.5 Tesla magnet in combination with a transmit/receive wrist coil. Three-millimeter thick T1-weighted spin-echo images and 1-mm thick T2*-weighted gradient-recalled 3-D images were obtained in dorsal and sagittal planes. Carpi were embedded, sectioned, and stained. Anatomic structures on the histologic sections were correlated with the MR images. All of the carpal ligaments plus the radioulnar articular disc and the palmar fibrocartilage were identified on MR images. The accessorio-quartile ligament, which had not been well described previously in dogs, was also identified. It originated on the accessory carpal bone and inserted on the fourth carpal bone. The T2*-weighted gradient echo imaging technique provided better images than T1-weighted technique, largely because thinner slices were possible (1 mm vs. 3 mm), resulting in less volume averaging of thin ligaments with surrounding structures. Although MRI is currently the imaging modality of choice to identify ligamentous injury in humans, further studies are needed to determine if abnormalities can be detected in canine carpal ligaments using MRI.  相似文献   

5.
Accurate interpretation of thoracic magnetic resonance images requires a thorough knowledge of anatomy of this region. The purpose of this communication is to describe the normal cross sectional anatomy of the thoracic cavity of the cat, using MR images, dissections and macroscopic sections. In this study, three cats were used. The animals were anesthetized and positioned in sternal recumbency in the MR scanner. MR imaging was performed at the Special Diagnostic Service of San Roque Clinic of Las Palmas de Gran Canaria with a superconducting magnet operating at a field strength of 1.5 Tesla and a human body coil. Spin echo pulse sequences were used to obtain T1-weighted images in tranverse and sagittal planes. At the conclusion of imaging, the cats were euthanatized for medical reasons unrelated to disease of thorax. The cats were frozen and then sectioned using an electric band saw. The cuts were matched as closely as possible to the MR images for identifying the normal planimetric anatomy of the thoracic structures. MR T1-weighted spin echo images provided excellent anatomic appearance of the thorax structures. In MR images the grey scale is directly related to the signal intensity of the thoracic cavity structures. Thus, fat and nerves had higher signal intensity compared with the lower signal intensity of the respiratory system. Bone marrow and muscles had a intermediate signal intensity and appeared gray. The intensity signal of the articular fluid permits a good differentiation of the opposing cartilage surfaces on all MR images. The planimetric or sectional anatomy of the thoracic cavity in the cat allows a correct morphologic and topographic evaluation of the anatomic structures, being helpful tool for the identification of the MR images. The information presented should serve as an initial reference to evaluate MR images of the feline thorax and to assist interpretation of lesions of this region.  相似文献   

6.
The purpose of this study was to describe the normal magnetic resonance (MR) imaging characteristics of the palmar structures of the equine podotrochlear apparatus by means of retrospective evaluation of MR imaging studies of 16 cadaver limbs. The articular aspect of the distal sesamoid bone was not evaluated in this study. Equine digits were imaged with a human knee radiofrequency coil in a 1.5 T magnetic field, using spin echo (SE) T1-weighted, turbo spin echo proton density (TSE PD)-weighted with and without fat saturation (FS), and FS TSE T2-weighted sequences. The limbs were dissected after imaging to validate the absence of gross abnormalities of the flexor aspect of the distal sesamoid bone, of the deep digital flexor tendon, and the distal impar sesamoidean ligament. Seven deep digital flexor tendons were subjected to histologic examination to exclude any microscopic tendon pathology. The anatomic structures of the podotrochlear apparatus were easily identified on MR images. Compact bone of the flexor cortex of the distal sesamoid bone had low intensity signal on all sequences. In 11 digits an increased signal was seen within the thickness of the sagittal eminence of the flexor cortex in SE T1-weighted images and in TSE PD-weighted images without FS. Trabecular bone had a granular appearance and high signal in SE T1-weighted sequences and TSE images without FS. The deep digital flexor tendon had low signal on FS T2-weighted images, while on short echo time sequences (T1- and PD-weighted sequences), the tendon signal varied depending on the relative orientation between its fibers and the static magnetic field. Seven tendons had stippled appearance due to small intratendonous foci of slightly increased signal on transverse T1-weighted images. MR imaging provides a thorough evaluation of the anatomical structure of the podotrochlear apparatus: A good knowledge of the MR imaging appearance and anatomy and an awareness of potential pitfalls will improve diagnostic specificity for the detection of pathologic changes.  相似文献   

7.
T2-weighted fast spin echo and conventional spin echo are two magnetic resonance (MR) pulse sequences used to image the brain. Given the same scan parameters the resolution of fast spin-echo images will be inferior to that of conventional spin-echo images. However, fast spin-echo images can be acquired in a shorter time allowing scan parameters to be optimized for increased resolution without increasing the time to an unacceptable level. MR imaging of the brain of 54 dogs, suspected of having parenchymal brain abnormalities was performed using a 1.5 T scanner. Acquisition time ranged from 4 min 24 s to 7 min 16 s (average = 5 min 15 s) for fast spin-echo scans and from 6 min 32 s to 11 min 26s (average = 7 min 55s) for conventional spin-echo scans. All reviewers consistently rated the resolution of fast spin-echo images higher than the conventional spin-echo images (P = 0.000). The potential disadvantages of fast spin-echo acquisitions (motion artifacts, blurring, and increased hyperintensity of fat) did not affect the resolution of the images. Fast spin echo offers increased resolution in a comparable time to conventional spin echo by increased number of excitations and finer matrix size, thus improving the signal-to-noise ratio and spatial resolution, respectively.  相似文献   

8.
When ex vivo magnetic resonance (MR) imaging studies are undertaken, specimen conservation should be taken into account when interpreting MR imaging results. The purpose of this study was to assess MR changes during time in the anatomic structures of the equine digit on eight cadaver limbs stored at 4°C. The digits were imaged within 12 h after death and then after 1, 2, 7, and 14 days of refrigeration. After the last examination, four feet were warmed at room temperature for 24 h and reimaged. Sequences used were turbo spin echo (TSE) T1, TSE T2, short tau inversion recovery (STIR), and double-echo steady state (DESS). Images obtained were compared subjectively side by side for image quality and signal changes. Signal-to-noise ratio (SNR) was measured and compared between examinations. There were no subjective changes in image quality. A mild size reduction of the synovial recesses was detected subjectively. No signal change was seen subjectively except for bone marrow that appeared slightly hyperintense in STIR and slightly hypointense in TSE T2 sequence after refrigeration compared with day 0. Using quantitative analysis, significant SNR changes in bone marrow of refrigerated limbs compared with day 0 were detected in STIR and TSE T2 sequences. Warming at room temperature for 24 h produced a reverse effect on SNR compared with refrigeration with a significant increase in SNR in TSE T2 images. After 14 days of refrigeration a statistically significant decrease of SNR was found in bone marrow in TSE T2 and DESS sequences. The SNR in the deep digital flexor tendon was not characterized by significant change in SNR.  相似文献   

9.
10.
The purpose of the present study was to describe normal magnetic resonance (MR) imaging anatomy of the equine larynx and pharynx and to present the optimal protocol, sequences, and possible limitations of this examination technique. Using a 0.3 T unit, the laryngeal and pharyngeal regions was imaged in two horses. The protocol consisted of sagittal and transverse T2-weighted (T2w) fast spin echo, transverse T1-weighted (T1w) spin echo, and dorsal high-resolution T1w gradient echo (both pre- and postcontrast enhancement) sequences. Euthanasia was performed at the end of the imaging procedure. Macroscopic anatomy of the cadaver sections were compared with the MR images in transverse, midsagittal, and parasagittal planes. There was good differentiation of anatomic structures, including soft tissues. The laryngeal cartilages, hyoid apparatus, and upper airway muscle groups with their attachments could be clearly identified. However, it was not always possible to delineate individual muscles in each plane. Most useful were both T2w and T1w transverse sequences. Intravenous application of contrast medium was helpful to identify blood vessels. The MR images corresponded with the macroscopic anatomy of cadaver sections.  相似文献   

11.
The canine meninges are not visible as discrete structures in noncontrast magnetic resonance (MR) images, and are incompletely visualized in T1‐weighted, postgadolinium images, reportedly appearing as short, thin curvilinear segments with minimal enhancement. Subtraction imaging facilitates detection of enhancement of tissues, hence may increase the conspicuity of meninges. The aim of the present study was to describe qualitatively the appearance of canine meninges in subtraction MR images obtained using a dynamic technique. Images were reviewed of 10 consecutive dogs that had dynamic pre‐ and postgadolinium T1W imaging of the brain that was interpreted as normal, and had normal cerebrospinal fluid. Image‐anatomic correlation was facilitated by dissection and histologic examination of two canine cadavers. Meningeal enhancement was relatively inconspicuous in postgadolinium T1‐weighted images, but was clearly visible in subtraction images of all dogs. Enhancement was visible as faint, small‐rounded foci compatible with vessels seen end on within the sulci, a series of larger rounded foci compatible with vessels of variable caliber on the dorsal aspect of the cerebral cortex, and a continuous thin zone of moderate enhancement around the brain. Superimposition of color‐encoded subtraction images on pregadolinium T1‐ and T2‐weighted images facilitated localization of the origin of enhancement, which appeared to be predominantly dural, with relatively few leptomeningeal structures visible. Dynamic subtraction MR imaging should be considered for inclusion in clinical brain MR protocols because of the possibility that its use may increase sensitivity for lesions affecting the meninges.  相似文献   

12.
13.
The purpose of this study was to produce an magnetic resonsnce (MR) image atlas of clinically relevant brain anatomy and to relate this neuroanatomy to clinical signs. The brain of a large mixed breed dog was imaged in transverse, sagittal, and dorsal planes using a 1.5 T MR unit and the following pulse sequences: Turbo (fast) spin echo (TSE) T2, T1, and T2- weighted spatial and chemical shift-encoded excitation sequence. Relevant neuroanatomic structures were identified using anatomic texts, sectioned cadaver heads, and previously published atlases. Major subdivisions of the brain were mapped and the neurologic signs of lesions in these divisions were described. TSE T2-weighted images were found to be the most useful for identifying clinically relevant neuroanatomy. Relating clinical signs to morphology as seen on MR will assist veterinarians to better understand clinically relevant neuroanatomy in MR images.  相似文献   

14.
The objective of this study was to define the anatomy of the cranioencephalic structures and associated formations in camel using magnetic resonance imaging (MRI). MR images were acquired in sagittal, transverse and oblique dorsal planes, using spin-echo techniques, a magnet of 1.5 T and a standard human body coil. MR images were compared with corresponding frozen cross-sections of the head. Different anatomic structures were identified and labelled at each level. The resulting images provided excellent soft tissue contrast and anatomic detail of the brain and associated structures of the camel head. Annotated MR images from this study are intended to be a reference for clinical imaging studies of the head of the dromedary camel.  相似文献   

15.
Alberto  Arencibia  DVM  PhD  Jose M.  Vázquez  DVM  PhD  Raduán  Jaber  DVM  Francisco  Gil  DVM  PhD  Juan A.  Ramiírez  MD  PhD  Miguel  Rivero  DVM  Nelson  González  DVM  PhD  Erik R.  Wisner  DVM 《Veterinary radiology & ultrasound》2000,41(4):313-319
The purpose of this investigation was to define the magnetic resonance imaging anatomy of the rostral part of the equine head. 10 mm-thick, T1-weighted images of two isolated equine cadaver heads were obtained using a 1.5 Tesla magnet and a body coil. MR images were compared to corresponding frozen cross-sections of the cadaver head. Relevant anatomic structures were identified and labeled at each level. The resulting images provided excellent anatomic detail of the oral and nasal cavities, paranasal sinuses and associated structures. Annotated MR images from this study are intended as a reference for clinical MR imaging studies of the equine head.  相似文献   

16.
17.
Three dogs with multilobular osteochondrosarcoma of the skull were evaluated using magnetic resonance (MR) imaging. Spin echo T1, T2, proton weighted and post contrast T1W images were obtained with a 1.5 Tesla magnet. The MR imaging findings were similar in all three dogs with mixed signal intensities in the T1W, T2W and proton weighted images and fairly large areas of contrast enhancement in the post contrast T1W images. The extent of brain and soft tissue involvement were well delineated and provided useful information concerning surgical planning. MR imaging provided a useful method of evaluating dogs with skull tumors.  相似文献   

18.
Margaret A.  Blaik  DVM  R. Reid  Hanson  DVM  Steven A.  Kincaid  DVM  MS  PhD  John T.  Hathcock  DVM  MS  Judith A.  Hudson  DVM  PhD  Debra K.  Baird  DVM  PhD 《Veterinary radiology & ultrasound》2000,41(2):131-141
The objective of this study was to define the normal gross anatomic appearance of the adult equine tarsus on a low-field magnetic resonance (MR) image. Six radiographically normal, adult, equine tarsal cadavers were utilized. Using a scanner with a 0.064 Tesla magnet, images were acquired in the sagittal, transverse and dorsal planes for T1-weighted and the sagittal plane for T2-weighted imaging sequences. Anatomic structures on the MR images were identified and compared with cryosections of the imaged limbs. Optimal image planes were identified for the evaluation of articular cartilage, subchondral bone, flexor and extensor tendons, tarsal ligaments, and synovial structures. MR images provide a thorough evaluation of the anatomic relationships of the structures of the equine tarsus.  相似文献   

19.
Evaluation of brain disease in veterinary patients uses a wide variety of MRI sequences. A shortened protocol that maintains consistency of interpretation would reduce radiologist reporting time, patient anesthetic time, and client cost. The aims of this retrospective, methods comparison, observer agreement study were to evaluate whether abbreviated MRI protocols alter differential diagnoses and recommendations compared to our institution's standard protocol; evaluate interobserver agreement on standard brain MRIs; and assess whether differential diagnoses change after postcontrast images. Normal and pathologic canine and feline brain MRIs were retrieved from hospital archives. Three protocols were created from each: a 5-sequence noncontrast enhanced Fast Brain Protocol 1 (FBP1); a 6-sequence contrast-enhanced Fast Brain Protocol 2 (FBP2); and an 11-sequence standard brain protocol (SBP). Three blinded veterinary radiologists interpreted FBP images for 98 cases (1 reader/case) and SBP images for 20 cases (3 readers/case). A fourth observer compared these interpretations to the original MRI reports (OMR). Overall agreement between FBPs and OMR was good (k = 0.75) and comparable to interobserver agreement for multiple reviews of SBP cases. Postcontrast images substantially altered conclusions in 17/97 cases (17.5%), as well as improved interobserver agreement compared to noncontrast studies. The conclusions reached with shortened brain protocols were comparable to those of a full brain study. The findings supported the use of a 6-sequence brain MRI protocol (sagittal T2-weighted [T2w] TSE; transverse T2w turbo spin echo fluid-attenuated inversion recovery, T2*-weighted gradient recalled echo, T1-weighted spin echo, and diffusion weighted imaging/apparent diffusion coefficient; and postcontrast transverse T1-weighted spin echo) for dogs and cats with suspected intracranial disease.  相似文献   

20.
A stereotactic brain biopsy system that is magnetic resonance (MR) imaging-guided has not been validated in dogs. Our purpose was to determine the mean needle placement error in the caudate nucleus, thalamus, and midbrain of a canine cadaver brain using the modified Brainsight stereotactic system. Relocatable reference markers (fiducial markers) were attached to the cadaver head using a dental bite block. A T1-weighted gradient echo three-dimensional (3D) sequence was acquired using set parameters. Fiducial markers were used to register the head to the acquired MR images in reference to a 3D position sensor. This allowed the planning of trajectory path to brain targets in real time. Coordinates (X, Y, Z) were established for each target and 0.5 microl of diluted gadolinium was injected at each target using a 26-gauge needle to create a lesion. The center of the gadolinium deposition was identified on the postoperative MR images and coordinates (X', Y', Z') were established. The precision of this system in bringing the needle to target (needle placement error) was calculated. Seventeen sites were targeted in the brain. The mean needle placement error for all target sites was 1.79 +/- 0.87 mm. The upper bound of error for this stereotactic system was 3.31 mm. There was no statistically significant relationship between needle placement error and target depth (P = 0.23). The ease of use and precision of this stereotactic system support its development for clinical use in dogs with brain lesions > 3.31 mm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号