Transvenous cardiac pacing in 19 dogs and one cat   总被引:2,自引:0,他引:2  
Eighteen dogs and one cat with symptomatic bradycardias were equipped with cardiac pacemakers. One further dog died during anaesthesia for pacemaker placement. Each animal was sedated, and a ‘tined’ transvenous pacing lead was passed to the apex of the right ventricle from the jugular vein. Following temporary pacing and general anaesthesia, the permanent pacemaker was placed subcutaneously at the neck in the dogs and at the abdominal wall in the cat. In 11 dogs and the cat, the pacemaker was implanted in a dacron pouch. Complications (mainly serous reaction to the pacemaker) developed in four out of seven dogs in which no pouch had been employed. The pacing lead was retained after discharge from hospital in all except one dog. Pacing successfully relieved clinical signs in all cases. Fifteen out of 18 dogs and the cat survived one year after pacing and the mean survival time was greater than 18 months. Transvenous pacing is a simple and reliable technique that avoids transthoracic or transabdominal surgery for pacemaker lead placement.  相似文献   

2.
ObjectiveTo determine the feasibility of atrial septal pacing via a delivery catheter-guided small non-retracting helix pacing lead.AnimalsSix healthy beagles (8.3-12.9 kg).MethodsUsing single plane fluoroscopic guidance, Medtronic® 3830 SelectSecure leads were connected to the atrial septum via Medtronic® Attain Select® II standard 90 Left Heart delivery catheter. Pacing threshold and lead impedance were measured at implantation. The Wenckebach point was tested via atrial pacing up to 220 paced pulses per minute (ppm). Thoracic radiographs were performed following implantation to identify the lead position, and repeated at 24 h, 1 month, and 3 months post-operatively.ResultsMacro-lead dislodgement occurred in two dogs at 24 h and in three dogs at one-month post-implantation. Lead impedance, measured at the time of implantation, ranged from 583 to 1421 Ω. The Wenckebach point was >220 ppm in four of the six dogs. The remaining two dogs had Wenckebach points of 120 and 190 ppm.ConclusionsThis pilot study suggests the selected implantation technique and lead system were inadequate for secure placement in the atrial septum of these dogs. The possible reasons for inadequate stability include unsuitable lead design for this location, inadequate lead slack at the time of implantation and inadequate seating of the lead as evidenced by low impedance at the time of implantation. Other implantation techniques and/or pacing leads should be investigated to determine the optimal way of pacing the atria in small breed dogs that are prone to sinus node dysfunction.  相似文献   

3.
Objective: To describe successful treatment of third-degree atrioventricular (AV) block using temporary noninvasive transthoracic pacing and placement of a permanent transvenous pacemaker in a case of suspected lily-of-the-valley ( Convallaria majalis ) intoxication in a dog.
Case summary: A 2-year-old neutered male Beagle weighing 17.8 kg was presented to the emergency service for treatment of bradycardia, vomiting, and lethargy. An electrocardiogram revealed third-degree AV block that was nonresponsive to atropine. Ten hours after admission, the dog became obtunded. Treatment initially consisted of temporary noninvasive transthoracic pacing and eventually placement of a permanent transvenous pacemaker. The initial history did not suggest that the dog had access to any known cardiotoxins. However, C. majalis , which contains cardiac glycosides, was identified within the dog's environment and the dog's serum did contain digoxin or an immunologically cross-reactive compound.
New or unique information provided: This is the first reported successful management of C. majalis toxicosis in a dog. Temporary noninvasive transthoracic pacing was used in the management of this case as a safe and effective bridge to permanent pacemaker implantation.  相似文献   

4.
Transvenous cardiac pacing is a commonly employed treatment for symptomatic bradyarrhythmias in dogs. Medical management of these conditions has not proven to be successful leaving pacing as the only viable alternative. The technique of pacemaker implantation is not difficult, but successful pacemaker therapy requires an understanding of electrophysiology, cardiac fluoroscopic anatomy, pacemaker instrumentation, and programming. Proper patient selection and identification of the underlying rhythm disturbance is essential to a successful clinical outcome. This article discusses the indications, equipment, techniques, complications, and outcome of permanent transvenous cardiac pacing.  相似文献   

5.
Surgical implantation of a sutureless myocardial electrode and pulse generator was performed in 18 dogs, using a ventral abdominal, transdiaphragmatic approach. Twelve dogs were greater than or equal to 10 years old. The 18 dogs weighed from 3 to 54 kg. Indications for permanent cardiac pacemaker implantation included complete (3rd degree) atrioventricular block, sick sinus syndrome, and sinus bradycardia. Few complications developed during or after surgery. One dog died during surgery from ventricular fibrillation, and hypertrophic cardiomyopathy was found at necropsy. Five dogs died 1 to 19 months after surgery (mean, 8.6 months) because of renal failure, hepatic cirrhosis, congestive cardiomyopathy, or idiopathic causes. Twelve dogs were alive 1 to 48 months after surgery (mean, 15.1 months). The surgical approach was used a second time in 3 dogs to replace the myocardial electrode wire and pulse generator 4, 16, and 26 months after surgery; technical complications were not associated with the second surgery in these 3 dogs. In 2 dogs that had initial pacemaker implantation via lateral thoracotomy, a transdiaphragmatic approach was used to replace the myocardial electrode lead and pulse generator 25.5 and 26 months after surgery. According to results of this study, the ventral abdominal, transdiaphragmatic approach for permanent pacemaker implantation in the dog is a simpler technique, with decreased surgery time, decreased time of tissue exposure, and decreased rate of infection, as compared with results described by investigators who used lateral thoracotomy or midline celiotomy and caudal one-third median sternotomy.  相似文献   

6.
Temporary cardiac pacing is used in the emergency treatment of life-threatening bradyarrhythmias and for the support of heart rate and blood pressure of patients with sick sinus syndrome or high-grade atrioventricular (AV) block undergoing general anesthesia, typically for permanent pacemaker implantation. We retrospectively evaluated the safety and efficacy of a noninvasive transthoracic external cardiac pacing system in 42 dogs treated for bradyarrhythmias. Optimal placement of the patch electrodes on the skin of the thorax was initially established on 2 anesthetized normal dogs. The optimal electrode placement was determined to be on the right and left hemithoraces, directly over the heart. Afterward, by means of this electrode placement all 42 dogs treated for bradyarrhythmias in this study were successfully paced with the noninvasive transthoracic system. Dogs ranged in age from 1 to 15 years and weighed between 3.2 and 40 kg. Miniature Schnauzers, German Shepherds, and mixed breeds were most common in the study population. Indications for noninvasive transthoracic pacing included emergency treatment of hemodynamically unstable 3rd-degree AV block (2 dogs): support of heart rate during general anesthesia for permanent pacemaker implantation or lead-wire adjustment (38 dogs): and support of heart rate during general anesthesia for ophthalmologic surgery in dogs with sick sinus syndrome (2 dogs). Complications included pain and skeletal muscle stimulation, which required general anesthesia. We conclude that the noninvasive transthoracic pacing system evaluated is satisfactory for clinical veterinary use.  相似文献   

7.
CASE DESCRIPTION: A 12-year-old Miniature Dachshund with a history of permanent endocardial pacemaker implantation performed 7 weeks previously was admitted for routine dental prophylaxis. CLINICAL FINDINGS: Preanesthetic ECG revealed normal ventricular capture. Thoracic radiographic findings included caudomedial displacement of the endocardial pacemaker lead. Echocardiography revealed moderate chronic degenerative valve disease with moderate left atrial and ventricular dilation. After induction of anesthesia, loss of ventricular capture was detected. The dog recovered from anesthesia and had improved ventricular capture. The following day, surgical exposure of the cardiac apex revealed perforation of the right ventricular apex by the passive-fixation pacemaker lead. TREATMENT AND OUTCOME: A permanent epicardial pacemaker was implanted through a transxiphoid approach. Appropriate ventricular capture and sensing were achieved. The dog recovered without complications. Approximately 2 months later, the dog developed sudden respiratory distress at home and was euthanized. CLINICAL RELEVANCE: In dogs with permanent pacemakers and loss of ventricular capture, differential diagnoses should include cardiac perforation. If evidence of perforation of the pacemaker lead is found, replacement of the endocardial pacemaker lead with an epicardial pacemaker lead is warranted.  相似文献   

8.
Tined transvenous pacing leads were inserted into nine healthy large-breed dogs as part of an experimental study evaluating an implantable defibrillator. The pacing leads were used to induce ventricular fibrillation on the day of insertion, two and four weeks after insertion and then monthly. Despite daily running exercise on and off a leash, the tined leads remained firmly anchored to the right ventricular apex for the full experimental period of up to 12 months. Apart from mechanical endocarditis of the tricuspid valve, and partial penetration of the ventricular wall in one dog, problems associated with the pacing leads were not encountered. The use of tined leads and careful technique may minimise the likelihood of transvenous lead displacement.  相似文献   

9.
A 10-year old male mongrel dog was presented to the University Veterinary Teaching Hospital with a two-month history of episodic syncope. Twenty-four hr Holter electrocardiographic (ECG) recording revealed frequent episodes of advanced atrioventriculer block with long periods of ventricular asystole. The cause of syncope was determined to be Adams-Stokes syndrome exhibited bradyarrhythmia. After the animal failed to respond to medical therapy, permanent transvenous pacemaker implantation was performed. Postoperative Holter ECG showed 100 beat per min programmed pacemaker rhythm, which indicated successful capture of the artificial pacing. The dog recovered smoothly from the operation and syncopal episodes completely disappeared. Six months after the surgery, no complications were observed and the dog's quality of life has dramatically improved.  相似文献   

10.
IntroductionIn dogs, single lead ventricular pacing, ventricular sensing, inhibition response, rate adaptive (VVIR) pacemakers are routinely used to treat third degree atrioventricular block. The objectives of this study were to investigate the heart rate distribution in dogs with VVIR pacemakers, and report changes when activity settings were adjusted.AnimalsEighteen client-owned dogs with VVIR pacemakers for third degree atrioventricular block.Materials and methodsThis observational study consisted of a review of medical records of dogs with VVIR pacemakers. For dogs with >50% of paced beats at the lower pacing rate, the activity daily living (ADL) and exertion responses were increased. Re-evaluations were performed after 6–12 months.ResultsHeart rate distribution similar to healthy dogs was absent for all dogs. In nine dogs, the ADL and exertion responses were increased to the highest level. Of these, three dogs showed no improvement in heart rate distribution; for two dogs, one with an epicardial pacemaker, several activity settings were adjusted and pacing at higher heart rates was observed at re-evaluation. Four dogs died or were lost to follow-up. Clinical signs had resolved for all dogs after pacemaker implantation.ConclusionDefault activity settings of VVIR pacemakers do not result in heart rate distribution equivalent to healthy dogs. Increasing the ADL and exertion response settings to the highest levels did not improve the pacemaker rate response. Further investigations into the role of dog size, generator positioning, pacemaker settings, and whether rate responsiveness is required for dogs' quality and quantity of life are warranted.  相似文献   

11.
This study investigated the feasibility of using a modified transesophageal atrial pacing system for dogs requiring temporary ventricular pacing. Atrial pacing was readily achieved in the one dog studied, but it caused considerable diaphragmatic movement. Ventricular pacing could not be achieved at any lead configuration or energy stimulation. While transesophageal cardiac pacing was a safe procedure, the large variation in the chest anatomy of dogs requires further study to explore this model as a substitute for transvenous or transthoracic ventricular pacing.  相似文献   

12.
Inferior vena cava obstruction, a rare but serious complication of transvenous pacemaker lead placement in humans, has not been reported in dogs. We describe this complication in a dog that developed ascites 8 months after pacemaker implantation. Radiography disclosed a loop of redundant lead within the caudal vena cava (CVC), and angiography demonstrated obstruction to blood flow. Withdrawal of the loop from the CVC did not restore blood flow. Persistent obstruction was suspected secondary to fibrosis resulting from vascular damage caused by the loop of lead. Angioplasty of the CVC obstruction restored blood flow and resolved the dog's clinical signs.  相似文献   

13.
Background: Pacemaker implantation is the treatment of choice for symptomatic bradyarrhythmias. In dogs, a single chamber system is commonly used. In human patients with high-grade 2nd- or 3rd-degree atrioventricular (AV) block, physiologic pacing is recommended, because it improves cardiac output, blood pressure, exercise tolerance, and quality of life. In dogs, this type of pacing is seldom used.
Hypothesis: The implantation of a dual chamber pacemaker in dogs with AV block is a feasible procedure for restoring AV synchrony.
Animals: Thirty-three privately owned dogs with high-grade 2nd- or 3rd-degree AV block were included.
Methods: Patient data of all dogs with AV block presented for pacemaker implantation between December 1997 and November 2004 were reviewed.
Results: Dual chamber pacemaker implantation with AV synchronous stimulation was successfully performed in 33/33 dogs (100%). In 9/33 (27%) major and in 12/33 (36%) minor complications were observed. Mean survival time for the patients discharged from hospital (n = 32) was 33.6 ± 20.4 months (range, 3.9–83.5 months).
Conclusion and Clinical Importance: Dual chamber pacing is a feasible procedure in dogs with 2nd- or 3rd-degree AV block and is not associated with a higher complication rate compared with single chamber pacemaker systems. A major advantage over ventricular demand pacemaker systems is the restoration of AV synchrony for a substantial period of time.  相似文献   

14.
A 2-year-old male castrated boxer dog was presented because of a history of syncope. Electrocardiogram tracings obtained with a cardiac event monitor showed bradycardia culminating in asystole. Sick sinus syndrome was diagnosed and treated with transvenous implantation of a dual-chambered permanent pacemaker.  相似文献   

15.
Objective: This case report presents the clinical findings of a dog with diltiazem intoxication and the utilization of temporary transvenous pacing for management of high‐grade second‐degree atrioventricular (AV) block with associated bradycardia and hypotension. Case summary: A nine‐year‐old spayed female Basset Hound, who ingested between 95 and 109 mg/kg of sustained‐release diltiazem exhibited clinical signs of cardiac arrhythmias, bradycardia, hypotension, mental depression and gastrointestinal (GI) upset. Bradycardia was present initially, then was followed by high‐grade second‐degree AV block with ventricular escape. Traditional medications to treat calcium channel blocker (CCB) intoxication, including atropine, calcium gluconate, dopamine and glucagon were initially successful in managing the cardiac rhythm disturbances and hypotension. Twenty‐two hours post‐ingestion, however, the dog became refractory to these medications following sedation for GI decontamination and a temporary transvenous pacemaker was placed. The dog was paced for 19 hours. Transvenous pacing effectively increased heart rate, which increased blood pressure into an acceptable range. The dog was successfully discharged from the hospital following treatment. New or unique information provided: The use of a temporary pacemaker should be considered an acceptable treatment for bradycardia, AV block and hypotension associated with CCB intoxication when conventional medical therapy fails.  相似文献   

16.
Pacemakers are commonly implanted by veterinary cardiologists in dogs with bradyarrhythmias. In the past, these pacemakers were placed with little attention to programming except for the basic heart rate. However, the availability of pacing programmers has permitted a better appreciation of the needs for proper and safe pacing in dogs. An awareness of the problems that can result from improper programming is imperative. We report the identification of noise reversion (inappropriate asynchronous pacing) in 42% of dogs consecutively paced (n = 19) at Cornell University during a 2 year period. Noise reversion is the operation that causes the pacemaker to switch to asynchronous pacing with repetitive refractory sensing. It was developed as a protective mechanism against noise being mistaken for cardiac events with the consequence of inhibition of pacing. However, in the dog, this operation can cause inappropriate, and potentially dangerous pacing. In the dog, this common complication is associated with the coexistence of a bradycardia and tachycardia. Proper programming of the refractory period (shortening) in conjunction with the sensitivity (decreasing the sensitivity) can eliminate noise reversion in dogs with both ventricular and atrial pacing.  相似文献   

17.
The case reported herein describes the placement of a permanent transvenous pacemaker in an older dog with a previously undiagnosed persistent left cranial vena cava (PLCVC) and recent onset symptomatic third-degree atrioventricular (AV) block. On presentation the dog was found to have atrial flutter and third-degree AV block and echocardiography demonstrated evidence of chronic valvular disease and pulmonary arterial hypertension. The persistent left cranial vena cava was discovered via angiography when difficulties were encountered with pacemaker placement. Successful right ventricular pacing necessitated passage of the lead through the coronary sinus. The attendant complications in pacemaker placement in the presence of a PLCVC are well-described in man but, to the authors' knowledge, have not been described in companion animals.  相似文献   

18.

Background

Increased cardiac troponin I (cTnI) concentration has been reported in dogs with atrioventricular (AV) block before and shortly following pacemaker implantation. The role of AV dyssynchrony, age, or concurrent cardiac disease on cTnI concentration remains unknown.

Objectives

To investigate change in cTnI concentration following dual-chamber pacemaker implantation on short- and long-term follow-up and to compare cTnI values to a case-matched control group.

Animals

Thirty-eight client-owned dogs with permanent AV block and 38 matched control dogs.

Methods

Retrospective review of medical records. Pacemaker group consisted of dogs with AV block and dual-chamber pacing. Control group matched the study population in age and cardiac disease. cTnI was compared between pacemaker and control group on short- and long-term follow-up. Different lead types and influence of arrhythmia on cTnI were tested.

Results

cTnI was high at presentation (median 0.66 ng/ml; range 0.03–18.6) and showed a significant reduction over time after pacemaker implantation (p < 0.0001). Median cTnI values were significantly different between pacemaker and control group on short-term (p = 0.0004; 0.11 ng/ml, range 0.03–1.36 versus 0.06 ng/ml, range 0.03–0.46), but not on long-term follow-up (p = 0.0547; 0.14 ng/ml, range 0.03–0.73 versus 0.07 ng/ml, range 0.03–0.46). Lead type and severity of arrhythmia did not show a significant correlation to cTnI concentration.

Conclusions

On long-term follow-up, cTnI remained mildly elevated in some of the pacemaker dogs but was not significantly different to the matched control group.  相似文献   

19.
A collie-cross dog with syncopal attacks associated with total atrioventricular heart block was successfully fitted with a programmable, ‘physiological’ pacemaker, employing atrial sensing and ventricular pacing leads. Transvenous placement of leads under sedation and local analgesia, followed by temporary pacing, then general anaesthesia for the fitting of a permanent pacemaker, offers advantages over epicardial pacing. The use of a ‘tined’ ventricular lead appears to reduce the risk of lead displacement.  相似文献   

20.
Two cats with bradycardia and syncope were treated by permanent pacemaker implantation. Cat 1 had multiple episodes of syncope intermittently over a 10-month period and then multiple episodes within 24 hours; cat 2 had episodes of collapse over a 3-month period. Clinical signs included disorientation, vocalization, and collapse. High-grade second-degree AV block was recorded in both cats, with left and right bundle branch block in cat 1 and right bundle branch block in cat 2. Neither responded to pharmacologic therapy. In cat 1, an epimyocardial electrode was implanted into the left ventricular apex by a ventral abdominal transdiaphragmatic surgical approach. Cat 2 had a permanent smooth endocardial pacing lead introduced into the fight external jugular vein and directed into the right ventricular apex. Both cats were clinically normal within three days after implantation. Complications in cat 2 included failure of pacemaker capture, endocardial lead dislodgement, and pulse generator pocket seroma. Cats with symptomatic bradycardia caused by second-degree and third-degree AV block can be effectively treated by pacemaker implantation by surgical endomyocardial or perivenous endocardial lead placement.  相似文献   