首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 494 毫秒
1.
The aim of the present study was to establish which adrenal gland measurement was characterized by the least variations. To do this, we quantified the variability of seven different size measurements of the canine adrenal gland (maximal length, maximal height at the cranial and caudal poles on longitudinal and transverse images, and maximal width of the cranial and caudal poles) within observer, between observer, and between dogs based on three different measurements made by each of the three observers in six healthy Beagle dogs. The height of the caudal pole of both adrenal glands measured on longitudinal images had the lowest intra‐ and interobserver variability, while measurements of the length had the highest intra‐ and interobserver variability. Other measurements that were characterized by low intra‐ and interobserver variability were: height and width of the caudal pole on transverse images and height of the cranial pole on longitudinal images only. These results provide a basis for further study of the changes in adrenal gland size in dogs with pituitary‐dependent hyperadrenocorticism.  相似文献   

2.
OBJECTIVE: To describe the anatomic features of the pituitary gland region in horses via computed tomography (CT) and determine the accuracy of CT for estimating normal equine pituitary gland dimensions. ANIMALS: 25 adult horses with no clinical signs of pituitary disease. PROCEDURE: Transverse CT images and gross transverse tissue sections were compared in 2 horses. Contrast-enhanced CT of the pituitary gland region was performed postmortem in 23 horses with 4 slice thickness and interval settings (10-mm contiguous or overlapping slices and 4-mm contiguous or overlapping slices). Gross and CT estimates of pituitary gland dimensions were compared via ANOVA. Accuracy of CT estimates was calculated with gross pituitary gland measurements as the known value. RESULTS: Pituitary glands were located between the temporomandibular joints and had contrast enhancement. Mean gross dimensions were length, 2.11 cm; width, 2.16 cm; height, 0.98 cm; and volume, 2.66 cm3. Gross measurements and CT estimates of pituitary gland length from 10-mm contiguous and overlapping slices did not differ. Gross measurements and CT estimates of pituitary gland width from 4-mm contiguous and overlapping slices did not differ. Estimates of height and volume from all CT techniques differed from gross measurements. Accuracies for CT estimates were length, 88 to 99%; width, 81 to 92%; height, 58 to 71%; and volume, 43 to 55%. CONCLUSIONS AND CLINICAL RELEVANCE: Accuracy of estimates of pituitary gland dimension in horses varied with CT scanning technique; via CT estimates of length and width of glands were more accurate than estimates of height or volume.  相似文献   

3.
The repeatability of ultrasonographic measurements of the canine thyroid gland was evaluated. The variability of three different parameters (the maximal length, width, and height) within observer, between observer and between dogs was assessed based on three different measurements made by each of three observers infive healthy beagle dogs. From the three parameters, the volume of the gland was estimated using a formula of a rotation ellipse. The height and the volume had the lowest intra- and interobserver variability, while measurements of the length had the biggest intra- and interobserver variability. The mean values, with their 90% confidence interval were: height = 0.53cm [0.33-0.73], length = 2.45cm [2.04-2.85], width = 0.62cm [0.46- 0.78], volume = 0.38 cm3 [0.20-0.55].  相似文献   

4.
The purpose of this study was to determine the optimal window level and width for accurate measurement of pituitary gland height in a phantom. A phantom, mimicking the appearance of the pituitary gland, was made by using the base of a canine skull immersed in buttermilk. Seven different-sized cylindrical pieces of cheese were made and the real diameter of each sample was measured by using a caliper. The cheese was then placed in the pituitary fossa, and 2-mm thick contiguous computed tomography (CT) slices were acquired. The height of the cheese was measured using electronic calipers with different window width and level (WW-WL) settings. The mean difference between CT and manual caliper measurements and concordance correlation coefficients were calculated for all settings. CT measurements underestimated manual caliper measurements with all settings, but the smallest difference (0.5 mm) was obtained with a 250-80 window. Concordance coefficients ranged from 0.699 to 0.820, with the maximum concordance coefficient obtained with a 250-80 window. A second series of measurements using a different window setting for the brain-pituitary gland edge (WW-WL: 250-80) and for the bone-pituitary gland edge (WW-WL: 250-240) resulted in a reduction in the mean difference (0.1 mm) and an increase in the concordance coefficient (0.836). It was concluded that underestimation of the height of the pituitary gland on CT images is most likely due to erroneous placement of the edge of the basisphenoid bone using a low level and a narrow window.  相似文献   

5.
The objective of this study was to examine the influence of the size, age and sex of the horse on the size of the pituitary gland and determine the possibility of using the pituitary gland height‐to‐brain area ratio (P:B ratio) to allow comparison of different sized and aged horses. Thirty‐two horses without pituitary pars inter‐media dysfunction that underwent a contrast‐enhanced computed tomographic (CT) examination were included in a cross‐sectional study. On the CT images, the pituitary gland height was measured and the P:B ratio was calculated. These measurements were correlated to the size, age and sex of the horses. The pituitary gland height was significantly associated with the size (P < 0.001) and the age (P < 0.001), but not with the sex (P = 0.40), of the horses. No significant association was found between the P:B ratio and the size (P = 0.25), the age (P = 0.06) or the sex (P = 0.25) of the horses. In conclusion, the pituitary gland size varies between different sized and aged horses. The use of the P:B ratio is a valuable metric for making comparisons between the pituitary glands of these horses.  相似文献   

6.
The aim of this retrospective reference interval observational study was to determine the mensuration of the pituitary gland (hypophysis cerebri) by analyzing CT studies in rabbits without clinical evidence of pituitary disease or central neurologic signs. Though diseases of the rabbit pituitary gland are uncommon, the pituitary gland is essential in regulation of the rabbit's endocrine system, as in other species. Currently, there are minimal published studies that detail the rabbit head anatomy on cross‐sectional imaging, and even less specifically examining the pituitary gland. The pituitary gland was measured by one observer at a single time point from transverse and reconstructed sagittal CT images in a soft‐tissue algorithm in 62 rabbits for a total of 66 rabbit head CT studies. The rabbits ranged from 0.84 to 14 years in age (mean ± SD: 5.46 ± 3.05 years) and 0.92 to 4.95 kg in weight (2.21 ± 0.83 kg). Linear pituitary measurements were performed using electronic calipers. The mean ± SD pituitary height was 4.22 ± 0.57 mm, width was 4.48 ± 0.71 mm, and length was 6.02 ± 0.70 mm. The pituitary gland height‐to‐brain area ratio was 1.10 ± 0.16 mm?1, which is much higher than the values reported in normal dogs and cats. The age, weight, and sex of the rabbits were not found to have a significant impact on pituitary gland mensuration. These measurements could be useful as a reference range for future rabbit head CT studies and to rule out pituitary enlargement or disease when evaluating rabbit pituitary glands.  相似文献   

7.
Measurement of the tibial plateau slope from lateral hind-limb radiographs is a preoperative requirement when performing tibial plateau leveling osteotomy (TPLO) for repair of the cruciate-deficient stifle in dogs. Two measurements of the tibial plateau slope in 312 stifles of 156 dogs were taken from lateral radiographs by each of three observers with varying degrees of experience in the measurement method. Intraobserver variability was +/-3.4 degrees, and interobserver variability was +/-4.8 degrees. No significant differences were identified for the intraobserver measurements; however, in evaluating interobserver variability, a significant difference was found between the inexperienced observer and the two experienced observers.  相似文献   

8.
Adrenal length and width were determined from two-dimensional ultrasound longitudinal images. In study 1, 540 measurements of adrenal glands were attempted from five healthy beagle dogs by three different observers with different levels of expertise in ultrasonography, to determine the variability of adrenal gland measurements. Of these, 484 measurements were included in the statistical analysis, since 16 measurements of the left adrenal gland and 40 for the right could not be visualised by the observer. In study 2, a single measurement of both adrenal glands was taken from each of 146 dogs by the most trained observer from study 1, and the effects of different health status (healthy dogs v dogs with non-adrenal diseases), bodyweight, age and sex were assessed. A total of 267 measurements were included in the statistical analysis. The lowest intra- and inter-day coefficient of variation values were observed for the left adrenal gland and by the most trained observer. The health status had no statistically significant effect on adrenal gland length or width, whereas age had a significant effect only for the left adrenal gland (the greater the age, the greater the width or length) and sex had a significant effect only for the right adrenal gland (the width was larger in males and the length larger in females). The bodyweight had a significant effect for the length of both adrenal glands (the greater the bodyweight, the greater the length), but not the width. The differences between sd and coefficient of variation values for the width of the left adrenal gland were not statistically significant between the three observers, whereas they were statistically significant for the right adrenal gland.  相似文献   

9.
Most prostatic diseases in dogs are associated with prostatomegaly, and transabdominal ultrasonography has become the imaging modality of choice for evaluation of the prostate gland in the dog. The aim of the present study was to assess the reproducibility, the repeatability and interobserver variations of sonographic measurements of prostate and to determine which measurement had the lowest variability. Length and height of prostate gland were measured on longitudinal views, width of the prostate gland and height of left and right lobes of the gland on transversal views. The within‐day and between‐day variabilities of the prostatic parameters were determined by performing 1350 (270 length, 270 height, 270 width, 270 height of right lobe and 270 height of left lobe) examinations on ten healthy intact beagle dogs on six different days, in a two‐week period (three days for the five dogs, three different days for the five others). Three observers with different levels of experience in ultrasonography performed the examinations. The lowest within‐day and between‐day standard deviation and coefficient of variation values were observed for the width of the prostate. The width of the gland measured on transverse frozen images seems to be the most reliable measurement for evaluating size of prostate glands in healthy dogs, although the shape, position, outline, and echogenicity of the prostate should also be assessed.  相似文献   

10.
Objectives : To describe the computed tomography (CT) features of the prostate gland and determine prostate size using CT in entire male dogs. Methods : The prostate gland was evaluated in 35 dogs. Morphological features including homogeneity, delineation, shape and intraprostatic differentiation were assessed. Height, length, width, area, volume and attenuation values of the prostate gland were measured. Ratios of prostatic height (rH), length and width to the sixth lumbar vertebral body length were calculated. Relationships of prostatic dimensions with body weight and age were evaluated. Results : The prostate gland was homogeneous in 29 dogs on non‐contrast images and 18 of 24 dogs on postcontrast images. Transverse images revealed a semi‐oval prostate gland in 29 dogs and irregularly shaped prostate gland in 6 dogs. A prominent median septum was observed in postcontrast images. Significant positive correlations were found between body weight and age and all prostatic dimensions except between age and rH. The mean ±sd values for attenuation were 59·3 ±9·1 and 121·3 ±22·7 HU in non‐contrast and postcontrast image, respectively. Clinical Significance : CT can be useful for evaluating morphological features of the prostate gland. Prostatic length or width is a better measure than height for computed tomographic estimation of prostate size.  相似文献   

11.
OBJECTIVE: To assess the intra- and interobserver repeatability of 2-dimensional (2-D) kinematic analysis of walk and sit-to-stand motions in dogs. ANIMALS: 10 healthy adult Labrador Retrievers. PROCEDURES: 10 dogs were filmed during walk and sit-to-stand motions. Five trials were recorded for each dog, 3 of which were digitized. Two observers manually marked 15 landmarks on each frame during the motions of interest for these 3 trials. Each observer repeated the procedure approximately 1 week later. The 2-D joint angles were calculated. Intra- and interobserver coefficients of multiple correlations (CMCs) were calculated for each joint angle-time history. RESULTS: Intraobserver repeatability, assessed as the mean CMCs of 12 joint angle measurements made for 10 dogs by 2 observers, was good or excellent in 23 of 24 (96%) mean CMCs of the joints measured. Interobserver variation, assessed by comparing CMCs of measurements made by 2 observers on 10 dogs on 2 days, was good or excellent in 161 of 240 (67%) CMCs of joints measured. CONCLUSIONS AND CLINICAL RELEVANCE: Intraobserver repeatability of 2-D kinematic measurements made on digitized videotapes was excellent. Interobserver repeatability of these measurements was acceptable.  相似文献   

12.
Hege  Kippenes  DVM  Patrick R.  Gavin  DVM  PhD  Susan L.  Kraft  DVM  PhD  Ronald D.  Sande  DVM  MS  PhD  Russell L.  Tucker  DVM 《Veterinary radiology & ultrasound》2001,42(2):130-133
The pituitary gland was measured from transverse magnetic resonance T1-weighted images after Gadolinium administration in 96 dogs weighing from 13 to 45 kg. The measurements were done by hand with calipers. The mean (+/- standard deviation) pituitary gland height was 5.1 mm (+/-0.9 mm). The mean width was 6.4 mm (+/- 1.1 mm). The correlation coefficient between pituitary and brain measurements, between pituitary measurement and body weight, and brain measurements and body weight was 0.0 to 0.3. A hyperintense region was present on T1-weighted images in the center of the pituitary gland in 64% of the dogs. At necropsy the pituitary glands were grossly and histologically normal. No pituitary gland measurements were performed at necropsy.  相似文献   

13.
Objective— To compare the intra‐ and interobserver variability occurring when observers with differing experience levels measure tibial plateau angles (TPAs) with a novel digital radiographic projection program (tibial plateau leveling osteotomy [TPLO] planning program), the Kodak Picture Archiving and Communications System (PACS), and standard sized printed films (SF). Study Design— Cross‐sectional study. Sample Population— Dogs (n=36) with cranial cruciate ligament (CCL) rupture that had a TPLO. Methods— Six observers, divided into 3 equal groups based on experience level, measured TPA on 36 digitally captured radiographic images of tibiae of dogs clinically affected with CCL rupture. Each observer used 3 methods of measuring TPA and repeated the measurements 3 times with each method. The intra‐ and interobserver variability was compared using the coefficient of variation. Results— Averaged over all replications and images, there was no significant difference (P>.05) in the average variability occurring with each method for all but 1 observer. There was no effect of experience level on measurement variability; however, interobserver variability was significantly less with measurements made with the PACS and TPLO planning program compared with measurements made from SF (P<.05). Conclusions— Repeated measurements of TPA made using digital images and computer‐based measurement programs were significantly less variable between observers than those made from images printed on standard radiographic films. Clinical Relevance— Digital radiography and computer‐based measurement programs are effective for determining the TPA, allowing less variability in measurements compared with SF. The ability to manipulate the image may allow better identification of anatomic landmarks.  相似文献   

14.
Cisternography combined with linear tomography was performed in ten clinically healthy dogs (weighing 14-33 kg) to visualize the pituitary gland, and results were compared with the results from sagittal midline computed tomography (CT) in these dogs. With cisternography, the length of the pituitary gland of nine dogs ranged from 5.7 to 9.9 mm (mean ± SD, 7.9 ± 1.3), and the width from 5.4 to 8.7 mm (6.4 ± 1.0). With sagittal linear tomography following cisternography, the height of the pituitary gland of these nine dogs ranged from 4 to 6 mm (5.1 ± 0.7); and, with sagittal CT, it ranged from 4.3 to 6 mm (5.0 ± 0.6). In an 11-year-old female Greyhound, two small nodules were found at the periphery of the pituitary gland using cisternography but were not recognized on CT images. It is concluded that cisternography combined with linear tomography is a safe and accurate alternative for the visualization of the pituitary gland when CT is not available.  相似文献   

15.
OBJECTIVE: To assess intra- and interobserver repeatability of ocular biometric measurements obtained by means of high-resolution B-mode ultrasonography in dogs. Animals-6 Beagles without ocular abnormalities. PROCEDURES: B-mode ultrasonography was performed bilaterally with a 10.5-MHz broadband compact linear array transducer. All measurements were made on 2 different occasions by 2 observers. The Bland-Altman method was used to assess agreement between measurements obtained by the 2 observers and between the 2 sets of measurements obtained by each observer. RESULTS: Intra- and interobserver repeatability was highest for larger measurements, such as depth of the eye and depth of the anterior chamber. When repeatability was examined, bias was significantly different from 0 for only a few measurements, but the percentage difference between observations was as high as 180% for some measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that most measurements of intraocular distances and structures obtained by means of high-resolution B-mode ultrasonography have acceptable intra- and interobserver repeatability. However, the percentage difference between observations can be high for smaller measurements.  相似文献   

16.
OBJECTIVES: To determine the agreement between observers and to investigate the effect of observer experience in diagnosing canine hip dysplasia and providing final scoring of hips using the standard ventrodorsal hip-extended radiographic method. The agreement of the final scoring, with a presumed correct assessment based on the Norberg angle, is also investigated. METHODS: Thirty observers were requested to read 50 ventrodorsal hip-extended radiographs of 25 dogs according to Federation Cynologique International criteria. Groups of experienced (nine members) and inexperienced (21 members) observers were used. RESULTS: For providing the distinction between dysplastic versus non-dysplastic dogs, the average interobserver agreement was 72 per cent and was significantly higher (P<0.0001) than the score that could be expected by chance without any agreement between observers. For providing the final score (A, B, C, D or E), an average interobserver agreement of 43.6 per cent was found. In the experienced group, an agreement score of 76 per cent was found for the distinction between AB versus non-AB and an agreement score of 81 per cent was found for the distinction between C versus non-C. The agreement score was significantly higher (P<0.0001) for the experienced group than for the inexperienced group in all cases. Agreement between the presumed correct assessment based on the Norberg angle and the observer's evaluation was low (P=0.35), irrespective of whether the observers were experienced (71.8 per cent correct assessments) or inexperienced (69 per cent correct assessments). CLINICAL SIGNIFICANCE: Although interobserver agreement is low, observer experience increases agreement.  相似文献   

17.
Dynamic helical computed tomography (CT) of the pituitary gland can be used to image the three-dimensional shape and dimensions of abnormalities within the pituitary gland. The aim of this study was to develop a protocol for dynamic helical CT of the pituitary gland in healthy dogs as a future reference study for patients with pituitary disease. Dynamic helical series of nine scans of the pituitary gland during and following contrast medium injection were performed in six healthy dogs using the following protocols: a series with 1 mm collimation and a table feed per X-ray tube rotation of 2 mm (pitch of 2) in six dogs, a series with 2 mm collimation and pitch of 2 in three dogs, and a series with 1 mm collimation and pitch of 1 in three other dogs. Multiplanar reconstructions of the images were made using a reconstruction index of 0.5. Images of all series were assessed visually for enhancement of the arteries, the neurohypophysis, and the adenohypophysis. The enhancement pattern of the neurohypophysis was distinguished adequately from that of the adenohypophysis in five dogs that were scanned with 1 mm collimation and pitch of 2, but the difference was less discernable when the other protocols were used. The carotid artery, its trifurcation, and the arterial cerebral circle were best visualized in dorsal reconstructions. Dynamic helical CT of the pituitary gland in healthy dogs can be performed with 1 mm collimation and pitch of 2, and a scan length that includes the entire pituitary region. Using this protocol, with the specific scanner used, the neurohypophysis, the adenohypophysis, and the surrounding vascular structures are adequately visualized.  相似文献   

18.
Objective— To evaluate agreement and repeatability of vertebral column measurements using computed tomography (CT) and magnetic resonance imaging (MRI).
Study Design— Retrospective observational study.
Animals— Dogs (n=18) with disc associated wobbler syndrome; Dog cadavers (n=3).
Methods— Five measurements of the 5th cervical vertebra were performed: vertebral body length (VBL), vertebral canal height (VCH), vertebral body height (VBH), vertebral canal width (VCW), and vertebral body width (VBW). Measurements were performed independently twice by 2 observers. Bland-Altman plots were created to evaluate agreement. Cadaveric vertebrae with soft tissue removed had the same variables and actual dimensions measured.
Results— The largest discrepancy between CT and MRI measurement was for VBL (mean difference±SD=1.262 mm±1.245; P <.001), with the difference for all the other variables being acceptable. The 1st measurement was significantly higher than the 2nd only for VBL using CT (mean difference=0.476 mm±1.120; P =.009), with all other variables having acceptable differences. Mean difference for all measurements between 2 observers was small, except for VBL using CT (mean difference=0.762 mm±1.042; P <.001). Only the difference for VBL between CT and cadaver specimens was statistically significant.
Conclusions— Our results suggest high repeatability and good agreement for most vertebral measurements of interest. VBL measurement using CT was considered problematic.
Clinical Relevance— Provided limitations are understood, linear measurements of vertebral dimensions from CT and MRI images can be used clinically.  相似文献   

19.
Computed tomography (CT) provides excellent bony detail, whereas magnetic resonance (MR) imaging is superior in evaluating the neural structures. The purpose of this prospective study was to assess interobserver and intermethod agreement in the evaluation of cervical vertebral column morphology and lesion severity in Great Danes with cervical spondylomyelopathy by use of noncontrast CT and high‐field MR imaging. Fifteen client‐owned affected Great Danes were enrolled. All dogs underwent noncontrast CT under sedation and MR imaging under general anesthesia of the cervical vertebral column. Three observers independently evaluated the images to determine the main site of spinal cord compression, direction and cause of the compression, articular process joint characteristics, and presence of foraminal stenosis. Overall intermethod agreement, intermethod agreement for each observer, overall interobserver agreement, and interobserver agreement between pairs of observers were calculated by use of kappa (κ) statistics. The highest overall intermethod agreements were obtained for the main site of compression and direction of compression with substantial agreements (κ = 0.65 and 0.62, respectively), whereas the lowest was obtained for right‐sided foraminal stenosis (κ = 0.39, fair agreement). For both imaging techniques, the highest and lowest interobserver agreements were recorded for the main site of compression and degree of articular joint proliferation, respectively. While different observers frequently agree on the main site of compression using both imaging techniques, there is considerable variation between modalities and among observers when assessing articular process characteristics and foraminal stenosis. Caution should be exerted when comparing image interpretations from multiple observers.  相似文献   

20.
Dynamic computed tomography (CT) of the pituitary gland was performed in 55 dogs with pituitary-dependent hyperadrenocorticism (PDH) that underwent transsphenoidal hypophysectomy. On routine contrast-enhanced CT images, microadenomas of the pituitary gland often are indistinguishable from nontumorous pituitary tissue because of isoattenuation. Dynamic CT may allow visualization of these adenomas. The changes in the contrast-enhancement pattern of the pituitary during dynamic CT in 55 dogs with PDH were correlated with surgical and histopathologic findings. In 36 dogs, dynamic CT identified distinct contrast enhancement of the neurohypophysis (pituitary flush). In 24 dogs, this pituitary flush was displaced, which indicated the presence of an adenoma. This observation was confirmed surgically and histopathologically in 18 of the 24 dogs. In 19 dogs, there was a diffusely abnormal contrast-enhancement pattern. CT findings agreed with surgical findings in 13 of these dogs and with histopathologic findings in all 19 dogs. It is concluded that a dynamic series of scans should be included in the CT protocol of the pituitary gland in dogs with PDH because it allows for identification of an adenoma or a diffusely abnormal pituitary gland.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号