首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Objective: To compare the partial CO2 rebreathing method (non‐invasive cardiac output [NICO]) and the lithium dilution method (lithium dilution cardiac output [LiDCO]) for cardiac output (CO) measurement in anesthetized dogs. Design: Prospective study. Setting: College of Veterinary Medicine, University of Florida. Animals: Six adult dogs (weight range 22–25.4 kg). Interventions: All animals were instrumented for CO determinations using the LiDCO and NICO methods. Direct blood pressure, heart rate, arterial blood gases, end‐tidal isoflurane (ETI), and CO2 concentrations were monitored throughout the study. CO was manipulated with dobutamine and isoflurane to allow for intermediate, low, and high CO determinations in that order using LiDCO and NICO. Measurements and main results: A 1.5% ETI produced the intermediate rate of CO, a constant‐rate infusion of dobutamine (1–4 μg/kg/min) and 1.1% ETI, the highest rate, and 2.5–3% ETI, the lowest rate. Measurements were obtained in duplicate or triplicate for the LiDCO and continuously for the NICO method after achieving a stable hemodynamic plane for at least 15 minutes at each level of CO, allowing 5 minutes between measurements. Forty‐seven comparisons were determined. The correlation coefficient (r) between the 2 methods was 0.888 for all determinations. The mean LiDCO and NICO from 47 measurements were 155.9±78.7 mL/kg/min (range, 49.6–303.2) and 146.6±62.9 mL/kg/min (50–290.3), respectively. The bias between LiDCO and NICO estimations was 9.3 (?60.7 to +79.4) mL/kg/min (mean and 95% confidence interval). The mean (mL/kg/min) of the differences of LiDCO–NICO was 1.11 × NICO. The relative error was 2.4±24.7%. As CO increased, the relative difference between the methods also increased. Conclusions: The NICO is a viable non‐invasive method for CO determination in the dog and compares well with the LiDCO.  相似文献   

2.
Newer techniques for cardiac output (Q) determinations that are minimally invasive remain to be validated in neonatal foals against other accepted techniques such as the lithium technique (LiDCO). This study compares Q determinations using the partial CO2 rebreathing technique (NICO) with LiDCO in anesthetized neonatal foals. Ten foals were instrumented for NICO and LiDCO determinations. For each foal low, intermediate and high levels of cardiac output were achieved in that order using an end‐tidal isoflurane (ETI) concentration of 1.3 – 2.1% for the lowest rate; an ETI of 0.85–1.4% and a constant‐rate infusion of dobutamine (1–3 ?g/kg/min) for the intermediate rate; and an ETI of 0.83–1% and dobutamine (2–6 ?g/kg/min) for the highest rate. Four foals also received IV intermittent doses (total cumulative dose of 1.1–1.7 mg) of phenylephrine at the highest rate of Q. The measurements were obtained in duplicate or triplicate for each Q technique after achieving a stable hemodynamic plane for at least 15 minutes at each rate of Q. For the lithium technique, all foals received 1.1–1.9 mL (0.16–0.28 mmol) of lithium. A Bland‐Altman analysis was used to compare the bias and precision of the two techniques. Eighty seven comparisons were determined between the two techniques. Eight were excluded due to more than 20% variation between the LiDCO determinations or technical errors at the time of determination. The correlation coefficient between the two methods was 0.67 for all Q determinations. Mean LiDCO and NICO values from 79 measurements were 130 ± 40 mL–1 kg minute–1 (range, 68– 237) and 152 ± 31 mL–1 kg minute–1 (89 – 209), respectively. The mean ( mL–1 kg minute–1) of the differences of LiDCO – NICO was = –0.7248 + 0.8602 NICO. The precision (1.96 SD) of the differences between LiDCO and NICO was 58.9 mL–1 kg minute–1 (–80.9–+36.9) with a mean difference of –22 mL–1 kg minute–1 (bias; 95% CI – 15.2 to ‐28.7). In conclusion, given the small bias compared to the limits of agreement, the NICO technique for determining Q deserves further consideration for adoption into clinical practice in neonatal foals.  相似文献   

3.
OBJECTIVE: To evaluate the use of a lithium dilution cardiac output (LiDCO) technique for measurement of CO and determine the agreement between LiDCO and thermodilution CO (TDCO) values in anesthetized cats. ANIMALS: 6 mature cats. PROCEDURE: Cardiac output in isoflurane-anesthetized cats was measured via each technique. To induce different rates of CO in each cat, anesthesia was maintained at > 1.5X end-tidal minimum alveolar concentration (MAC) of isoflurane and at 1.3X end-tidal isoflurane MAC with or without administration of dobutamine (1 to 3 microg/kg/min, i.v.). At least 2 comparisons between LiDCO and TDCO values were made at each CO rate. The TDCO indicator was 1.5 mL of 5% dextrose at room temperature; with the LiDCO technique, each cat received 0.005 mmol of lithium/kg (concentration, 0.015 mmol/mL). Serum lithium concentrations were measured prior to the first and following the last CO determination. RESULTS: 35 of 47 recorded comparisons were analyzed; via linear regression analysis (LiDCO vs TDCO values), the coefficient of determination was 0.91. The mean bias (TDCO-LiDCO) was -4 mL/kg/min (limits of agreement, -35.8 to + 27.2 mL/kg/min). The concordance coefficient was 0.94. After the last CO determination, serum lithium concentration was < 0.1 mmol/L in each cat. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated a strong relationship and good agreement between LiDCO and TDCO values; the LiDCO method appears to be a practical, relatively noninvasive method for measurement of CO in anesthetized cats.  相似文献   

4.
The objective of this study was to assess 2 noninvasive methods of measuring cardiac output (CO) in neonatal foals by comparing results to that of the lithium-dilution method. Ten neonatal foals were anesthetized and CO was manipulated by varying the depth of anesthesia and infusion of dobutamine. Concurrent CO measurements were obtained by lithium dilution (reference method), partial carbon dioxide (CO2) rebreathing, volumetric echocardiography (cubic, Teichholz, Bullet, area-length, and single and biplane modified Simpson formulas), and transthoracic Doppler echocardiography. Thirty pairs of lithium-dilution/noninvasive CO measurements were taken from the 10 foals. For each method, relative bias was calculated as a percentage of the average CO. Lithium determinations of CO ranged between 3.09 and 1 1.1 L/min (mean +/- SD = 6.39 +/- 2.1 L/min), resulting in cardiac indices ranging between 79.0 and 209 mL/kg/min (mean +/- SD = 131 +/- 35.9 mL/kg/min). Relative bias of Doppler echocardiography significantly increased (P < .05), whereas that of partial CO2 rebreathing significantly decreased (P = .03) with increasing CO. Other methods were not influenced by the level of CO. Among methods not influenced by the level of CO, relative bias of the Bullet method (-4.2 +/- 20.9%; limits of agreement -45.2 to 36.7%) was significantly lower (P < .05) than that of each of the other noninvasive methods evaluated. Volumetric echocardiography using the Bullet method provides an accurate and noninvasive estimate of CO in anesthetized neonatal foals and warrants investigation in critically ill conscious foals.  相似文献   

5.
Objective – To compare cardiac output (CO) measured by use of lithium dilution (LiDCO) and ultrasound velocity dilution (UDCO) in conditions of high, intermediate, and low CO in anesthetized foals.
Design – Original prospective study.
Setting – University teaching hospital.
Animals – Six foals 1–3 days of age (38–45 kg).
Interventions – Neonatal foals were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO. The CO was measured by use of LiDCO and UDCO techniques. Measurements were obtained from each foal at baseline and during low, intermediate, and high CO states. Measurements were converted to cardiac index (cardiac index=CO/body weight) values for statistical analysis. Agreement between the 2 methods was determined using Bland and Altman analysis and concordance correlation coefficients.
Measurements and Main Results – LiDCO determinations of CO ranged between 4.0 and 14.0 L/min resulting in cardiac index ranging between 75.5 and 310 mL/kg/min. There was no significant effect of blood pressure variation on bias or relative bias ( P =0.62 and 0.93, respectively). The mean bias and relative bias of UDCO (±SD) compared with LiDCO were −20.1±39.2 mL/kg/min and −7.7±23.4%, respectively. Concordance correlation coefficient between LiDCO and UDCO was 0.833.
Conclusions – When compared with LiDCO, the UDCO technique has acceptable clinical utility for measuring CO in healthy anesthetized newborn foals.  相似文献   

6.
Objective – To compare the determination of cardiac output (CO) via arterial pulse pressure waveform analysis (FloTrac/Vigileo) versus lithium dilution method. Design – Prospective study. Setting – University teaching hospital. Animals – Six adult dogs. Interventions – Dogs were instrumented for CO determinations using lithium dilution (LiDCO) and FloTrac/Vigileo methods. Direct blood pressure, heart rate, arterial blood gases, and end‐tidal isoflurane (ETIso) and CO2 concentrations were measured throughout the study while CO was manipulated with different depth of anesthesia and rapid administration of isotonic crystalloids at 60 mL/kg/h. Measurements and Main Results – Baseline CO measurements were obtained at 1.3% ETIso and were lowered by 3% ETIso. Measurements were obtained in duplicate or triplicate with LiDCO and averaged for comparison with corresponding values measured continuously with the FloTrac/Vigileo method. For 30 comparisons between methods, a mean bias of ?100 mL/kg/min and 95% limits of agreement between ?311 and +112 mL/kg/min (212 mL/kg/min) was determined. The mean (mL/kg/min) of the differences of LiDCO?Vigileo=62.0402+?0.8383 × Vigileo, and the correlation coefficient (r) between the 2 methods 0.70 for all CO determinations. The repeatability coefficients for the individual LiDCO and FloTrac/Vigileo methods were 187 and 400 mL/kg/min, respectively. Mean LiDCO and FloTrac/Vigileo values from all measurements were 145 ± 68 mL/kg/min (range, 64–354) and 244 ± 144 mL/kg/min (range, 89–624), respectively. The overall mean relative error was 48 ± 14%. Conclusion – The FloTrac/Vigileo overestimated CO values compared with LiDCO and the relative error was high, which makes this method unreliable for use in dogs.  相似文献   

7.
OBJECTIVE: To compare cardiac output (CO) obtained by the lithium dilution method (LiDCO) with CO calculated from the Fick principle (FickCO), in horses maximally exercising on a high-speed treadmill. ANIMALS: 13 Thoroughbreds. PROCEDURES: In part 1 of the study, 5 horses performed a warm-up (walk, trot, and canter) and exercise test (walk, trot, canter, and gallop [90% to 100% maximum oxygen consumption [{[Formula: see text]O(2)max}]) with measurements of LiDCO and FickCO obtained simultaneously after 60 seconds at each exercise level, for a total of 7 measurements. In part 2 of the study, 8 horses performed a warm-up (walk, trot, and canter) followed by an exercise test (walk and gallop [90% to 100% [Formula: see text]O(2)max], repeated twice). Measurements of LiDCO and FickCO were obtained 60 seconds into the first walk and each gallop of the exercise tests, for a total of 3 measurements. RESULTS: Cardiac output increased significantly with increasing speeds by use of both methods. In part 1, lithium dilution significantly overestimated CO, compared with the Fick principle, during the exercise test (as both injection number and exercise intensity increased). Mean +/- SD bias was 246 +/- 264 mL of blood/min/kg in part 1 and 67 +/- 100mL of blood/kg/min in part 2. Three injections of lithium (part 2) did not result in the same degree of overestimation of LiDCO that was observed with 7 injections (part 1). CONCLUSIONS AND CLINICAL RELEVANCE: Lithium dilution may be an acceptable substitute for the Fick principle as a means to measure CO in maximally exercising client-owned horses.  相似文献   

8.
OBJECTIVES: To determine agreement of cardiac output measured by use of lithium dilution cardiac output (LiDCO) and thermodilution cardiac output (TDCO) techniques in dogs and to determine agreement of low- and high-dose LiDCO with TDCO. ANIMALS: 10 dogs (7 males, 3 females). PROCEDURE: Cardiac output was measured in anesthetized dogs by use of LiDCO and TDCO techniques. Four rates of cardiac output were induced by occlusion of the caudal vena cava, changes in depth of anesthesia, or administration of dobutamine. Lithium dilution cardiac output was performed, using 2 doses of lithium chloride (low and high dose). Each rate of cardiac output allowed 4 comparisons between LiDCO and TDCO. RESULTS: 160 comparisons were determined of which 68 were excluded. The remaining 92 comparisons had values ranging from 1.10 to 12.80 L/min. Intraclass correlation coefficient (ICC) between low-dose LiDCO and TDCO was 0.9898 and between high-dose LiDCO and TDCO was 0.9896. When all LiDCO determinations were pooled, ICC was 0.9894. For determinations of cardiac output < 5.0 L/min, ICC was 0.9730. Mean +/- SD of the differences of TDCO minus LiDCO for all measurements was -0.084+/-0.465 L/min, and mean of TDCO minus LiDCO for cardiac outputs < 5.0 L/min was -0.002+/-0.245 L/min. CONCLUSIONS AND CLINICAL RELEVANCE: The LiDCO technique is a suitable substitute for TDCO to measure cardiac output in dogs. Use of LiDCO eliminates the need for catheterization of a pulmonary artery and could increase use of cardiac output monitoring, which may improve management of cardiovascularly unstable animals.  相似文献   

9.
OBJECTIVE: To determine the relationship between bispectral index (BIS) and minimum alveolar concentration (MAC) multiples of isoflurane after IM injection of medetomidine or saline (0.9% NaCl) solution in anesthetized dogs. ANIMALS: 6 dogs. PROCEDURE: Each dog was anesthetized 3 times with isoflurane. First, the MAC of isoflurane for each dog was determined by use of the tail clamp method. Second, anesthetized dogs were randomly assigned to receive an IM injection of medetomidine (8 microg x kg(-1)) or an equal volume of isotonic saline (0.9% NaCl) solution 30 minutes prior to beginning BIS measurements. Last, anesthetized dogs received the remaining treatment (medetomidine or isotonic saline solution). Dogs were anesthetized at each of 4 MAC multiples of isoflurane. Ventilation was controlled and atracurium (0.2 mg/kg followed by 6 microg/kg/min as a continuous infusion, IV) administered. After a 20-minute equilibration period at each MAC multiple of isoflurane, BIS data were collected for 5 minutes and median values of BIS calculated. RESULTS: BIS significantly decreased with increasing MAC multiples of isoflurane over the range of 0.8 to 2.0 MAC. Mean (+/- SD) MAC of isoflurane was 1.3 +/- 0.2%. During isoflurane-saline anesthesia, mean BIS measurements at 0.8, 1.0, 1.5, and 2.0 MAC were 65 +/- 8, 60 +/- 7 52 +/- 3, and 31 +/- 28, respectively. During isoflurane-medetomidine anesthesia, mean BIS measurements at 0.8, 1.0, 1.5, and 2.0 MAC were 77 +/- 4, 53 +/- 7, 31 +/- 24, and 9 +/- 20, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: BIS monitoring in dogs anesthetized with isoflurane has a predictive value in regard to degree of CNS depression. During isoflurane anesthesia, our results support a MAC-reducing effect of medetomidine.  相似文献   

10.
OBJECTIVE: To assess the suitability of lithium dilution as a method for measuring cardiac output in anesthetized horses, compared with thermodilution and transesophageal Doppler echocardiography. ANIMALS: 6 horses (3 Thoroughbreds, 3 crossbreeds). PROCEDURE: Cardiac output was measured in 6 anesthetized horses as lithium dilution cardiac output (LiDCO), thermodilution cardiac output (TDCO), and transesophageal Doppler echocardiographic cardiac output (DopplerCO). For the LiDCO measurements, lithium chloride was administered i.v., and cardiac output was derived from the arterial lithium dilution curve. Sodium nitroprusside, phenylephrine hydrochloride, and dobutamine hydrochloride were used to alter cardiac output. Experiments were divided into 4 periods. During each period, 3 LiDCO measurements, 3 DopplerCO measurements, and 3 sets of 3 TDCO measurements were obtained. RESULTS: 70 comparisons were made between LiDCO, DopplerCO, and triplicate TDCO measurements over a range of 10 to 43 L/min. The mean (+/- SD) of the differences of LiDCO - TDCO was -0.86 +/- 2.80 L/min; LiDCO = -1.90 + 1.05 TDCO (r = 0.94). The mean of the differences of DopplerCO - TDCO was 1.82 +/- 2.67 L/min; DopplerCO = 2.36 + 0.98 TDCO (r = 0.94). The mean of the differences of LiDCO - DopplerCO was -2.68 +/- 3.01 L/min; LiDCO = -2.53 + 0.99 DopplerCO (r = 0.93). CONCLUSIONS AND CLINICAL RELEVANCE: These results indicate that lithium dilution is a suitable method for measuring cardiac output in horses. As well as being accurate, it avoids the need for pulmonary artery catheterization and is quick and safe to use. Monitoring cardiac output during anesthesia in horses may help reduce the high anesthetic mortality in this species.  相似文献   

11.
Minimally invasive cardiac output was determined using transthoracic bioimpedance (BICO), partial carbon dioxide rebreathing (NICO) and transesophageal Doppler echocardiography (TEECO) and compared to thermodilution (TDCO) in 6 beagle dogs. The dogs were 2 years old, weigh between 9.1-13.0 kg and were anesthetized with nitrous oxide-oxygen-sevoflurane. All dogs were administered a neuromuscular blocking drug and artificially ventilated during anesthesia. Thirty paired measurements of TDCO and each non-invasive method were collected during low, intermediate, and high values of cardiac output achieved by varying the depth of anesthesia and the administration of dobutamine. Cardiac output values ranged from 1.10-2.50 L/min for BICO compared to 0.81-4.88 L/min for TDCO; 0.70-2.60 L/min for NICO compared to 0.89-4.45 L/min for TDCO; and 0.59-4.37 L/min for TEECO compared to 0.57-4.15 L/min for TDCO. The limits of agreement and percentage error were -0.58 +/- 1.56 L/min and +/- 75.4% for BICO, -1.04 +/- 1.08 L/min and +/- 56.0% for NICO, and 0.03 +/- 0.26 L/min and +/- 12.3% for TEECO compared to TDCO. In conclusion, TEECO provided the best agreement to TDCO in sevoflurane anesthetized beagle dogs.  相似文献   

12.
Objective – To determine if metatarsal artery pressure (COmet) is comparable to femoral artery pressure (COfem) as the input for transpulmonary pulse contour analysis (PiCCO) in anesthetized dogs, using the lithium dilution method (LiDCO) as a standard for cardiac output (CO) measurement. Design – Prospective randomized study. Setting – University research laboratory. Animals – Ten healthy purpose‐bred mixed breed dogs were anesthetized and instrumented to measure direct blood pressure, heart rate, arterial blood gases, and CO. Interventions – The CO was measured using LiDCO and PiCCO techniques. Animals had their right femoral and left distal metatarsal artery catheterized for proximal (COfem) and distal (COmet) PiCCO analysis, respectively. Measurements were obtained from each animal during low, normal, and high CO states by changing amount of inhalant anesthetics and heart rate. Measurements were converted to CO indexed to body weigh (CIBW=CO/kg) for statistical analysis. Agreement was determined using Bland and Altman analysis and concordance correlation coefficients. Measurements and Main Results – Thirty paired measurements were taken. The LiDCO CIBW (± SD) was 68.7 ± 30.3, 176.0 ± 53.0, and 211.1 ± 76.5 mL/kg/min during low, normal, and high CO states, respectively. There was a significant effect of CIBW state on bias and relative bias with COmet (P<0.001 and P=0.003, respectively). Bias of the COmet method (± SD) was ?116.6 (70.5), 20.1(76.4), and 91.3 (92.0) mL/kg/min at low, normal, and high CIBW, respectively. Bias of the COfem (± SD) was ?20.3 (19.0), 8.6 (70.9), and ?2.9 (83.0) mL/kg/min at low, normal, and high CIBW, respectively. The mean relative bias for COfem was ?6.7 ± 44% (limits of agreements: ?81.2 to 67.9%). Conclusion – Compared with lithium dilution, the pulse contour analysis provides a good estimation of CO, but requires femoral artery catheterization in anesthetized dogs.  相似文献   

13.
OBJECTIVE: To determine the disposition of lidocaine after IV infusion in anesthetized horses undergoing exploratory laparotomy because of gastrointestinal tract disease. ANIMALS: 11 horses (mean +/- SD, 10.3 +/- 7.4 years; 526 +/- 40 kg). PROCEDURE: Lidocaine hydrochloride (loading infusion, 1.3 mg/kg during a 15-minute period [87.5 microg/kg/min]; maintenance infusion, 50 microg/kg/min for 60 to 90 minutes) was administered IV to dorsally recumbent anesthetized horses. Blood samples were collected before and at fixed time points during and after lidocaine infusion for analysis of serum drug concentrations by use of liquid chromatography-mass spectrometry. Serum lidocaine concentrations were evaluated by use of standard noncompartmental analysis. Selected cardiopulmonary variables, including heart rate (HR), mean arterial pressure (MAP), arterial pH, PaCO2, and PaO2, were recorded. Recovery quality was assessed and recorded. RESULTS: Serum lidocaine concentrations paralleled administration, increasing rapidly with the initiation of the loading infusion and decreasing rapidly following discontinuation of the maintenance infusion. Mean +/- SD volume of distribution at steady state, total body clearance, and terminal half-life were 0.70 +/- 0.39 L/kg, 25 +/- 3 mL/kg/min, and 65 +/- 33 minutes, respectively. Cardiopulmonary variables were within reference ranges for horses anesthetized with inhalation anesthetics. Mean HR ranged from 36 +/- 1 beats/min to 43 +/- 9 beats/min, and mean MAP ranged from 74 +/- 18 mm Hg to 89 +/- 10 mm Hg. Recovery quality ranged from poor to excellent. CONCLUSIONS AND CLINICAL RELEVANCE: Availability of pharmacokinetic data for horses with gastrointestinal tract disease will facilitate appropriate clinical dosing of lidocaine.  相似文献   

14.
OBJECTIVE: To determine minimum alveolar concentration (MAC) of isoflurane in green iguanas and effects of butorphanol on MAC. DESIGN: Prospective randomized trial. ANIMALS: 10 healthy mature iguanas. PROCEDURE: in each iguana, MAC was measured 3 times: twice after induction of anesthesia with isoflurane and once after induction of anesthesia with isoflurane and IM administration of butorphanol (1 mg/kg [0.45 mg/lb]). A blood sample was collected from the tail vein for blood-gas analysis at the beginning and end of the anesthetic period. The MAC was determined with a standard bracketing technique; an electrical current was used as the supramaximal stimulus. Animals were artificially ventilated with a ventilator set to deliver a tidal volume of 30 mL/kg (14 mL/lb) at a rate of 4 breaths/min. RESULTS: Mean +/- SD MAC values during the 3 trials (2 without and 1 with butorphanol) were 2.0 +/- 0.6, 2.1 +/- 0.6, and 1.7 +/- 0.7%, respectively, which were not significantly different from each other. Heart rate and end-tidal partial pressure of CO2 were also not significantly different among the 3 trials. Mean +/- SD heart rate was 48 +/- 10 beats/min; mean end-tidal partial pressure of CO2 was 22 +/- 10 mm Hg.There were no significant differences in blood-gas values for samples obtained at the beginning versus the end of the anesthetic period. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that the MAC of isoflurane in green iguanas is 2.1% and that butorphanol does not have any significant isoflurane-sparing effects.  相似文献   

15.
OBJECTIVE: To determine the effects of dobutamine, norepinephrine, and vasopressin on cardiovascular function and gastric mucosal perfusion in anesthetized foals during isoflurane-induced hypotension. ANIMALS: 6 foals that were 1 to 5 days of age. PROCEDURES: 6 foals received 3 vasoactive drugs with at least 24 hours between treatments. Treatments consisted of dobutamine (4 and 8 Sang/kg/min), norepinephrine (0.3 and 1.0 Sang/kg/min), and vasopressin (0.3 and 1.0 mU/kg/min) administered IV. Foals were maintained at a steady hypotensive state induced by a deep level of isoflurane anesthesia for 30 minutes, and baseline cardiorespiratory variables were recorded. Vasoactive drugs were administered at the low infusion rate for 15 minutes, and cardiorespiratory variables were recorded. Drugs were then administered at the high infusion rate for 15 minutes, and cardiorespiratory variables were recorded a third time. Gastric mucosal perfusion was measured by tonometry at the same time points. RESULTS: Dobutamine and norepinephrine administration improved cardiac index. Vascular resistance was increased by norepinephrine and vasopressin administration but decreased by dobutamine at the high infusion rate. Blood pressure was increased by all treatments but was significantly higher during the high infusion rate of norepinephrine. Oxygen delivery was significantly increased by norepinephrine and dobutamine administration; O2 consumption decreased with dobutamine. The O2 extraction ratio was decreased following norepinephrine and dobutamine treatments. The gastric to arterial CO2 gap was significantly increased during administration of vasopressin at the high infusion rate. CONCLUSION AND CLINICAL RELEVANCE: Norepinephrine and dobutamine are better alternatives than vasopressin for restoring cardiovascular function and maintaining splanchnic circulation during isoflurane-induced hypotension in neonatal foals.  相似文献   

16.
OBJECTIVE: To assess agreement between arterial pressure waveform-derived cardiac output (PCO) and lithium dilution cardiac output (LiDCO) systems in measurements of various levels of cardiac output (CO) induced by changes in anesthetic depth and administration of inotropic drugs in dogs. ANIMALS: 6 healthy dogs. PROCEDURE: Dogs were anesthetized on 2 occasions separated by at least 5 days. Inotropic drug administration (dopamine or dobutamine) was randomly assigned in a crossover manner. Following initial calibration of PCO measurements with a LiDCO measurement, 4 randomly assigned treatments were administered to vary CO; subsequently, concurrent pairs of PCO and LiDCO measurements were obtained. Treatments included a light plane of anesthesia, deep plane of anesthesia, continuous infusion of an inotropic drug (rate adjusted to achieve a mean arterial pressure of 65 to 80 mm Hg), and continuous infusion of an inotropic drug (7 microg/kg/min). RESULTS: Significant differences in PCO and LiDCO measurements were found during deep planes of anesthesia and with dopamine infusions but not during the light plane of anesthesia or with dobutamine infusions. The PCO system provided higher CO measurements than the LiDCO system during deep planes of anesthesia but lower CO measurements during dopamine infusions. CONCLUSIONS AND CLINICAL RELEVANCE: The PCO system tracked changes in CO in a similar direction as the LiDCO system. The PCO system provided better agreement with LiDCO measurements over time when hemodynamic conditions were similar to those during initial calibration. Recalibration of the PCO system is recommended when hemodynamic conditions or pressure waveforms are altered appreciably.  相似文献   

17.
The glomerular filtration rate (GFR) was estimated in eight full-term neonatal foals by the single injection inulin plasma clearance method at two days of age, the continuous infusion plasma and urinary clearance methods at three days of age, and the 12-hour endogenous creatinine clearance method at four days of age. The effective renal plasma flow (ERPF) was estimated simultaneously by the single injection para-aminohippuric acid (PAH) plasma clearance method in the eight two-day old foals and the continuous PAH infusion plasma and urinary clearance method in the eight three-day old foals. The GFR (+/- 1 SEM), as determined from the single injection plasma clearance method, was 2.30 +/- 0.34 mL/kg/min; by continuous infusion plasma clearance 2.56 +/- 0.30 mL/kg/min; by continuous infusion urinary clearance 2.82 +/- 0.32 mL/kg/min; and by 12-hour endogenous creatinine clearance 2.81 +/- 0.55 mL/kg/min. Effective renal plasma flow (+/- 1 SEM) measured by the single injection plasma clearance method was 15.22 +/- 1.5 mL/kg/min, by continuous infusion plasma clearance was 18.21 +/- 2.0 mL/kg/min. and by continuous infusion urinary clearance it was 11.95 +/- 1.9 mL/kg/min. The results of these methods were not statistically different. On a per kilogram body weight basis, the full-term neonatal foal's GFR and ERPF was determined to be comparable with adult equine GFR and ERPF.  相似文献   

18.
Cardiopulmonary effects of IV administered butorphanol tartrate (BUT) were assessed in 7 yearling steers medicated with atropine and anesthetized with guaifenesin, thiamylal sodium, and isoflurane in O2 for surgical placement of duodenal cannulae. Heart rate, respiratory rate, arterial blood pressures, pHa, PaCO2, PaO2, arterial [HCO3-], esophageal temperature, and end-tidal isoflurane concentrations were measured before and after IV administration of BUT (10 mg). Mean respiratory rate increased significantly (P less than 0.05) only at 45 and 60 minutes after BUT administration. Mean respiratory rate was 26 +/- 6.3 breaths/min before BUT administration and 46 +/- 12.1 breaths/min 60 minutes after BUT administration. Arterial blood pressures were increased significantly (P less than 0.05) at all times, except 5 minutes after BUT administration. The mean value for mean arterial pressure was 76 +/- 9.6 mm of Hg before BUT injection and 117 +/- 12.6 mm of Hg 60 minutes after BUT injection. Mean values for pHa and arterial [HCO3-] were significantly (P less than 0.05) higher at 60 minutes after BUT administration (baseline, pH = 7.25 +/- 0.04 and [HCO3-] = 29.9 +/- 3.5 mEq/L; 60 minutes after BUT, pH = 7.28 +/- 0.03 and [HCO3-] = 33.0 +/- 1.8 mEq/L). Although some statistically significant changes were recorded, IV administration of BUT to these steers did not have a marked effect on the cardiopulmonary variables measured.  相似文献   

19.
OBJECTIVE: To determine the effects of constant rate infusion of morphine, lidocaine, ketamine, and morphine-lidocaine-ketamine (MLK) combination on end-tidal isoflurane concentration (ET-Iso) and minimum alveolar concentration (MAC) in dogs anesthetized with isoflurane and monitor depth of anesthesia by use of the bispectral index (BIS). ANIMALS: 6 adult dogs. PROCEDURE: Each dog was anesthetized with isoflurane on 5 occasions, separated by a minimum of 7 to 10 days. Individual isoflurane MAC values were determined for each dog. Reduction in isoflurane MAC, induced by administration of morphine (3.3 microg/kg/min), lidocaine (50 microg/kg/min), ketamine (10 microg/kg/min), and MLK, was determined. Heart rate, mean arterial blood pressure, oxygen saturation as measured by pulse oximetry (Spo2), core body temperature, and BIS were monitored. RESULTS: Mean +/- SD isoflurane MAC was 1.38 +/- 0.08%. Morphine, lidocaine, ketamine, and MLK significantly lowered isoflurane MAC by 48, 29, 25, and 45%, respectively. The percentage reductions in isoflurane MAC for morphine and MLK were not significantly different but were significantly greater than for lidocaine and ketamine. The Spo2, mean arterial pressure, and core body temperature were not different among groups. Heart rate was significantly decreased at isoflurane MAC during infusion of morphine and MLK. The BIS was inversely related to the ET-Iso and was significantly increased at isoflurane MAC during infusions of morphine and ketamine, compared with isoflurane alone. CONCLUSIONS AND CLINICAL RELEVANCE: Low infusion doses of morphine, lidocaine, ketamine, and MLK decreased isoflurane MAC in dogs and were not associated with adverse hemodynamic effects. The BIS can be used to monitor depth of anesthesia.  相似文献   

20.
OBJECTIVE: To determine disposition kinetics of amikacin in neonatal foals administered high doses at extended intervals. ANIMALS: 7 neonatal foals. PROCEDURE: Amikacin was administered (21 mg/kg, i.v., q 24 h) for 10 days. On days 1, 5, and 10, serial plasma samples were obtained for measurement of amikacin concentrations and determination of pharmacokinetics. RESULTS: Mean +/- SD peak plasma concentrations of amikacin extrapolated to time 0 were 103.1 +/- 23.4, 102.9 +/- 9.8, and 120.7 +/- 17.9 microg/mL on days 1, 5, and 10, respectively. Plasma concentrations at 1 hour were 37.5 +/- 6.7, 32.9 +/- 2.6, and 30.6 +/- 3.5 microg/mL; area under the curve (AUC) was 293.0 +/- 61.0, 202.3 +/- 40.4, and 180.9 +/- 31.2 (microg x h)/mL; elimination half-life (t(1/2)beta) was 5.33, 4.08, and 3.85 hours; and clearance was 1.3 +/- 0.3, 1.8 +/- 0.4, and 2.0 +/- 0.3 mL/(min x kg), respectively. There were significant increases in clearance and decreases in t(1/2)beta, AUC, mean residence time, and plasma concentrations of amikacin at 1, 4, 8, 12, and 24 hours as foals matured. CONCLUSIONS AND CLINICAL RELEVANCE: Once-daily administration of high doses of amikacin to foals resulted in high peak plasma amikacin concentrations, high 1-hour peak concentrations, and large values for AUC, consistent with potentially enhanced bactericidal activity. Age-related findings suggested maturation of renal function during the first 10 days after birth, reflected in enhanced clearance of amikacin. High-dose, extended-interval dosing regimens of amikacin in neonatal foals appear rational, although clinical use remains to be confirmed.  相似文献   