首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
The glycosides of flavonoid, anthocyanins and A type proanthocyanidins in cranberry concentrate were characterized and quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Cranberry concentrate (1 g/body weight) was orally gavaged to Fischer-344 rats (n = 6), and blood and urine samples were collected over 24 h periods. Quercetin, 3'-O-methylquercetin (isorhamnetin), myricetin, kaempferol, and proanthocyanidin dimer A2, together with thirteen conjugated metabolites of quercetin and methylquercetin and intact peonidin 3-O-galactoside and cyanidin 3-O-galactoside were identified in the rat urine after cranberry treatment. Very low levels of isorhamnetin (0.48 ± 0.09 ng/mL) and proanthocyanidin dimer A2 (0.541 ± 0.10 ng/mL) were found in plasma samples after 1 h of cranberry administration. Although no quercetin was detected in plasma, MRM analysis of the methanolic extract of urinary bladder showed that chronic administration of cranberry concentrate to rats resulted in accumulation of quercetin and isorhamnetin in the bladder. These results demonstrate that cranberry components undergo rapid metabolism and elimination into the urine of rats and are present in the urinary bladder tissue potentially allowing them to inhibit urinary bladder carcinogenesis.  相似文献   

2.
The present paper describes a sensitive procedure for quantitative analysis of the Fusarium mycotoxins zearalenone and alpha-zearalenol in urine of ruminants. Extraction is done with an octadecyl (C18) column and cleanup with a silica column providing a preparation that is analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS). The trimethylsilyl ether derivatives of zearalenone and alpha-zearalenol yield molecular ions with m/z 462 and 536, respectively. These ions are selected in the first mass analyzer and then fragmented in a collision cell to give characteristic daughter ions (m/z 151, 333, 318, and 446). The method is known as multiple reaction monitoring (MRM). Elimination of chemical background noise by selecting proper fragment ions produces chromatograms in which identification and quantitation in a biological matrix is possible. The method was tested with sheep urine from an experimental feeding trial and was used to confirm natural mycotoxicosis of cows affected with zearalenone. Zearalenone (1 ppb) and alpha-zearalenol (14 ppb) were found in 2 different cow urine samples. The detection limit for both zearalenone and zearalenol is 1 ppb (1 ng/mL) in urine and is linear between 1 and 20 ppb for the former and 1 and 10 ppb for the latter.  相似文献   

3.
Seven FDA pesticide laboratories collaborated to develop and validate an LC-MS/MS method to determine 173 pesticides in <20 min. The average determination coefficient (r2) was >0.99 for all but two compounds tested. The limits of detection were <20 ng/mL for all compounds and <10 ng/mL for 363 of the 368 transitions reported. The method was used to determine pesticides in two AOAC sponsored proficiency samples. The LC-MS/MS determination was used for the analysis of oranges, carrots and spinach using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged, Safe) method. Each matrix was fortified at 20, 100, 400, and 1000 ng/g. No false positive responses were detected in controls of the three matrices. 165 pesticides had recoveries between 70 and 130%, and 161 had minimum detection levels less than 10 ng/g. Recoveries of 169 compounds for the 1000 ng/g spikes were within 50-150%. A matrix effect study indicated all three matrices caused a small net suppressing effect, the most pronounced attributable to the citrus matrix. The procedure proved to be accurate, precise, linear, sensitive and rugged, and adds 100 pesticides to the scope of the FDA pesticide program.  相似文献   

4.
A rapid LC-MS/MS method was developed for the quantitative determination of grayanotoxins I, II, and III in rumen contents, feces, and urine. The grayanotoxins were extracted from solid samples with methanol. The methanol extract was diluted with water and cleaned up using a reversed phase solid phase extraction column. HPLC separation was performed by reversed phase HPLC using a gradient of water and methanol containing 1% acetic acid. Determination was by positive ion electrospray ionization and ion trap tandem mass spectrometry. Grayanotoxin I quantitation was based on fragmentation of the sodium adduct ion at m/z 435 to a product ion at m/z 375. Grayanotoxins II and III were quantitated on the basis of fragmentation of the ion at m/z 335 to the product ion at m/z 299. The method detection limits were 0.2 microg/g in rumen contents and feces and 0.05 microg/g in urine. Fortifications at the detection limits and 10 times the detection limits of bovine rumen contents, caprine feces, and ovine urine were recovered in the range 80-114%. The diagnostic utility of the method was tested by analyzing samples submitted to the veterinary toxicology laboratory.  相似文献   

5.
An ultrahigh-performance liquid chromatography (UHPLC) tandem mass spectrometric (MS/MS) method was developed for the simultaneous quantification of 2-acetyl-4-tetrahydroxybutylimidazole (THI), 2- and 4-methylimidazoles (2-MI and 4-MI), and 5-hydroxymethylfurfural (HMF) in beverage samples. A C30 reversed-phase column was used in this method, providing sufficient retention and total resolution for all targeted analytes, with an MS/MS instrument operated in selected reaction monitoring (SRM) mode for sensitive and selective detection using isotope-labeled 4-methyl-d(3)-imidazole (4-MI-d(3)) as the internal standard (IS). This method demonstrates lower limit of quantification (LLOQ) at 1 ng/mL and coefficient of determination (r(2)) >0.999 for each analyte with a calibration range established from 1 to 500 ng/mL. This method also demonstrates excellent quantification accuracy (84.6-105% at 5 ng/mL, n = 7), precision (RSD < 7% at 5 ng/mL, n = 7), and recovery (88.8-99.5% at 10, 100, and 200 ng/mL, n = 3). Seventeen carbonated beverage samples were tested (n = 2) in this study including 13 dark-colored beverage samples with different flavors and varieties and 4 light-colored beverage samples. Three target analytes were quantified in these samples with concentrations in the range from 284 to 644 ng/mL for 4-MI and from 706 to 4940 ng/mL for HMF. THI was detected in only one sample at 6.35 ng/mL.  相似文献   

6.
A multiresidue method analyzing 209 pesticides in 24 agricultural commodities has been developed and validated using the original Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) procedure and high performance liquid chromatography-positive electrospray ionization-tandem mass spectrometry (LC-MS/MS) analysis. Using solvent-only calibration standards (SOCSs) and matrix-matched calibration standards (MMCSs), it was demonstrated that a minimal concentration of 5-10 μg/kg (part per billion, ppb) of analytes in matrix is required for the consistent identification of targeted pesticides with two MRM transitions. Method performance was validated by the precision and accuracy results obtained from fortification studies at 10, 25, 100, and 500 ppb and MMCSs. The method was demonstrated to achieve an average recovery of 100 ± 20% (n = 4) for >75% of evaluated pesticides at the low fortification level (10 ppb) and improved to >84% at the higher fortification concentrations in all 24 matrices. Matrix effects in LC-MS/MS analysis were studied by evaluating the slope ratios of calibration curves (1.0-100 ng/mL) obtained from the SOCSs and MMCSs. Principal component analysis (PCA) of LC-MS/MS and method validation data confirmed that each matrix exerts its specific effect during the sample preparation and LC-MS/MS analysis. The matrix effect is primarily dependent on the matrix type, pesticide type and concentration. Some caution is warranted when using matrix matched calibration curves for the quantitation of pesticides to alleviate concerns on matrix effects. The QuEChERS method with LC-MS/MS was used to identify and quantitate pesticides residues, with concentrations ranging from 2.5 to >1000 ppb in a variety of agricultural samples, demonstrating fitness for screening and surveillance applications.  相似文献   

7.
A liquid chromatography-mass spectrometric (LC-MS/MS) method has been developed for determination of ethynylestradiol residues in cattle hair. Hair samples were pulverized with a cryogenic mill followed by a simple extraction with acetonitrile. A dansyl derivatization procedure to improve ethynylestradiol detection was used before the LC-MS/MS analysis in multiple reaction monitoring (MRM) mode using alpha-estradiol as an internal standard. The method was validated following the latest EU guidelines using blank hair samples spiked at 2 ng g(-1). The detection capability (CCbeta) was less than 2 ng g(-1), and the decision limit (CCalpha) was 1 ng g(-1). Incurred samples obtained 56 days after cow treatment with ethynylestradiol were analyzed, and the presence of ethynylestradiol in the hair was confirmed in all cases.  相似文献   

8.
The method describes a rapid and accurate procedure for the analysis of ethyl carbamate in wines. The separation of the ethyl carbamate (EC), the target analyte, from alcohol and the sample matrix is a challenge to many analytical chemists. After alcohol removal from the sample, EC was extracted and concentrated by solid-phase extraction. For analysis of EC, large-volume injection on a programmable temperature vaporization (PTV) inlet was used followed by multidimensional gas chromatography/mass spectrometry (MDGC/MS) using electron-impact ionization (EI). For quantitation, the ratio of ions produced during EI at m/z 62 (EC) and 64 (isotopically labeled EC) was monitored. The use of solid-phase extraction and MDGC/MS removes the majority of the matrix interference encountered in other methods. A linear dynamic range was established from 0.387 to 1160 ng/mL, with a limit of detection at 0.1 ng/mL and limit of quantitation at 1 ng/mL.  相似文献   

9.
A liquid chromatography technique coupled with tandem mass spectrometry (LC-MS/MS) electrospray ionization was used to measure (-)-epigallocatechin-3-gallate (EGCG) in rat plasma. This method was applied to investigate the pharmacokinetics of EGCG in a conscious and freely moving rat by an automated blood sampling device. Multiple reaction monitoring (MRM) was used to monitor the transition of the deprotonated molecule m/z of 457 [M - H]- to the product ion 169 for EGCG and the m/z of 187 to 164 for the internal standard. The limit of quantification (LOQ) of EGCG in rat plasma was determined to be 5 ng/mL, and the linear range was 5-5000 ng/mL. The protein binding of EGCG in rat plasma was 92.4 +/- 2.5%. The brain distribution result indicated that EGCG may potentially penetrate through the blood-brain barrier at a lower rate. The disposition of EGCG in the rat blood was fitted well by the two-compartmental model after intravenous administration (10 mg/kg, iv). The elimination half-life of EGCG was 62 +/- 11 and 48 +/- 13 min for intravenous (10 mg/kg) and oral (100 mg/kg) administration, respectively. The pharmacokinetic data indicate that the oral bioavailability of EGCG in a conscious and freely moving rat was about 4.95%.  相似文献   

10.
采用固相萃取(SPE)为样品前处理方法,建立了超高效液相色谱-串联四极杆质谱联用(UPLC-MS/MS)检测土壤中咪唑乙烟酸的残留分析方法。土壤样品经0.1 mol.L-1的氯化铵与氨水缓冲液(pH=10)超声提取、C18SPE柱净化后,应用超高效液相色谱串联四级杆质谱仪多离子反应监测(MRM)定量检测,分别以碎片离子m/z 290〉176和m/z 290〉245进行外标法定量。结果表明,在0.01~0.5mg.kg-1添加水平范围内咪唑乙烟酸的平均添加回收率在83.47%~101.70%之间;相对标准偏差在4.15%~5.28%之间;咪唑乙烟酸的定量检出限(LOQ)为0.075μg.kg-1。该方法灵敏度高,操作简单,定量准确,可用于土壤中咪唑乙烟酸的残留分析。  相似文献   

11.
Analysis of coffee for the presence of acrylamide by LC-MS/MS   总被引:5,自引:0,他引:5  
A variety of popular instant, ground, and brewed coffees were analyzed using a modified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method specifically developed for the determination of acrylamide in foods. Coffee test portions were spiked with 13C3-labeled acrylamide as an internal standard prior to their extraction and cleanup. Ground coffees (1 g) and instant coffees (0.5 g) were extracted by shaking with 9 mL of water for 20 min. Brewed coffee test portions (9 mL) were taken through the cleanup procedure without further dilution with extraction solvent. Coffee test portions were cleaned up by passing 1.5 mL first through an Oasis HLB (hydrophilic/lipophilic copolymer sorbent) solid phase extraction (SPE) cartridge and then a Bond Elut-Accucat (cation and anion exchange sorbent) SPE cartridge. The cleaned up extracts were analyzed by positive ion electrospray LC-MS/MS. The MS/MS data was used to detect, confirm, and quantitate acrylamide. The limit of quantitation of the method was 10 ng/g for ground and instant coffees and 1.0 ng/mL for brewed coffee. The levels of acrylamide ranged from 45 to 374 ng/g in unbrewed coffee grounds, from 172 to 539 ng/g in instant coffee crystals, and from 6 to 16 ng/mL in brewed coffee.  相似文献   

12.
Tomato is a good source of bioactive molecules such as vitamin C, carotenoids, and phenolic compounds. Up to now, only a few studies have evaluated the bioavailability of phenolic compounds from tomato. This paper presents the optimization of a method for the determination of phenolics in tomato and their metabolites in human urine and plasma after ingestion of tomato sauce. The sample preparation includes a SPE step to obtain cleaner extracts for injection in the LC-MS/MS system. The mean recovery of analytes ranged from 73 to 104% in plasma and from 65 to 106% in urine, the accuracy was between 90.3 and 115.0% in urine and between 85.7 and 115.0% in plasma, and the precision coefficient of variation was <15%. The method allowed detection and quantification limits of 0.5-29 and 2.0-90 ng mL?1 in urine, respectively, and 0.5-30 and 2.0-105 ng mL?1 in plasma, respectively, for the same phenolic compounds.  相似文献   

13.
In this study, a nanocomposite of polypyrrole-coated magnetite nanoparticles (denoted as MNPs/PPy) was prepared and employed as magnetic solid-phase extraction (MSPE) sorbent for extraction of estrogens from milk samples. Because the polypyrrole coating possessed a highly π-conjugated structure and hydrophobicity, MNPs/PPy showed excellent performance for the estrogen extraction. Estrogens could be captured directly by MNPs/PPy from milk samples without protein precipitation. Moreover, the extraction could be carried out within 3 min. Thus, a rapid, simple, and effective method for the analysis of estrogens in milk samples was established by coupling MNPs/PPy-based MSPE with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The limits of detections for estrogens investigated were in the range of 5.1-66.7 ng/L. The recoveries of estrogens (concentration range of 0.5-20 ng/mL) from milk samples were in the range of 83.4-108.5%, with relative standard deviations ranging between 4.2 and 15.4%.  相似文献   

14.
采用分散固相萃取(QuEChERS)为样品前处理方法,建立了超高效液相色谱-串联四极杆质谱快速检测玉米及土壤中莠去津残留分析方法。玉米及土壤样品经乙腈提取、乙二胺-N-丙基硅烷(PSA)分散固相(DSPE)净化后,应用超高效液相色谱/电喷雾串联四极杆质谱仪多离子反应监测(MRM)定量检测,分别以碎片离子m/z216〉146和m/z216〉174定性,以m/z216〉96进行外标法定量。结果表明,在0.005~0.5mg·kg^-1添加水平范围内莠去津的平均添加回收率在77.01%~112.62%之间,相对标准偏差在2.23%~8.43%之间,对莠去津的检出限(LOD)为0.39~0.91μg·kg^-1,定量检出限(LOQ)为1.33~3.02μg·kg^-1。该方法灵敏度高,操作简单,定量准确,测定浓度范围宽,可用于莠去津的残留分析。  相似文献   

15.
A high-throughput liquid chromatography tandem mass spectrometry (HT LC-MS/MS) method for red blood cell (RBC) folate analysis was developed from a previously described manual (M) LC-MS/MS method. The HT LC-MS/MS method used 96-well plates in which RBC folates were hydrolyzed with concentrated HCl in the presence of the [13C6]pABA internal standard (IS). The pH of the hydrolysate was adjusted to 5.0 before cleanup using 96-well plate OASIS HLB SPE cartridges. The analyte and IS were eluted with ethyl acetate/hexane (95:5, v/v) and methylated with methanol and trimethylsilyldiazomethane. The methylated analyte and IS were quantified with LC-MS/MS as previously described. The HT LC-MS/MS method was validated by determining the recovery of six different folate vitamers, which were quantitatively recovered (84-105% with CV<9.0%). RBC folate concentrations in whole blood samples correlated between HT and M LC-MS/MS methods (r=0.922, p<0.0001 for n=43 samples) and between the HT LC-MS/MS method and a chemiluminescence assay (r=0.664, p<0.001 for n=325 samples). Comparison of the results between HT LC-MS/MS and chemiluminescence methods with Bland-Altman difference plots and by ROC curve analysis indicates that the chemiluminescence assay underreports RBC folate concentrations. The HT LC-MS/MS method allows for high-throughput sample preparation for the analysis of RBC folate.  相似文献   

16.
A monoclonal antibody-based ractopamine immunoassay has been applied to incurred samples from sheep and cattle. Results obtained by immunoassay were compared with those from high-performance liquid chromatography (HPLC). Three sets of sample extracts containing primarily unmetabolized ractopamine were analyzed. Correlation of HPLC with enzyme-linked immunosorbent assay (ELISA) for beef liver samples gave an r(2) = 0.98 despite rather low ractopamine concentrations (range 1.1-13.4 ng/mL, n = 6). Ractopamine concentrations in cow urine samples treated by solid phase extraction, to remove ractopamine metabolites, also showed a high correlation between the HPLC and the ELISA results (r(2) = 0.95, range 1.0-275 ng/mL, n = 61). In contrast, HPLC and ELISA analyses of ractopamine in sheep urine were not well-correlated (r(2) = 0.58, range 0.85-51 ng/mL, n = 34). When ractopamine conjugates in urine samples were hydrolyzed with hydrolytic enzymes, ELISA and HPLC methods were highly correlated [r(2) = 0.94 for sheep (range 123-10 554 ppb, n = 60) and an r(2) = 0.98 for cattle (range 14-8159 ppb, n = 62)]. Tissues contained only minute amounts of ractopamine, and after 7-day withdrawal periods, less than 1 ppb of free ractopamine was detected. Ractopamine was rapidly metabolized in both cattle and sheep. The difference in ractopamine concentration of urine samples before and after hydrolysis indicated that only 1-5% of ractopamine was excreted unmetabolized. Results from this study indicate that the monoclonal antibody-based ELISA could be useful for a sensitive, quantitative, or qualitative ractopamine screening assay.  相似文献   

17.
N-nitrosodimethylamine (NDMA) is one of the most important disinfection by-products (DBPs) due to its carcinogenicity even at low concentrations which correspond to the levels occurring in drinking water and wastewater effluents. Therefore, NDMA is a candidate DBP that is expected to be regulated in the near future. However, the measurement of NDMA in the low nanogram per liter range is challenging because of the limitations of analytical techniques including both the sample preparation and the LC-MS/MS. Moreover, the accuracy of most of the current methods is only tested for drinking water and no information is present for other matrices. In this study, a combination of solid-phase extraction (SPE) and LC-MS/MS method that does not require high-resolution MS or advanced techniques for sample pretreatment is developed. Moreover, important factors that affect the optimization of the SPE method are provided to enable readers to optimize their own SPE procedures if necessary. The proposed method was validated for surface water, groundwater, and wastewater samples and the method quantification limit was 2?ng/L. In addition, the proposed method was used to determine the concentration of NDMA precursors measured as NDMA formation potential (NDMAFP) throughout a drinking water treatment plant at two different sampling periods. NDMAFP decreased by approximately 40?% in both samples. The concentrations ranged between 4 and 11.5?ng/L and the presence of these low concentrations underlines the need for an easy to use, yet sensitive method for the determination of NDMA in environmental matrices.  相似文献   

18.
The area cultivated with Artemisia annua for the extraction of the antimalarial compound artemisinin is increasing, but the environmental impact of this cultivation has not yet been studied. A sensitive and robust method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of artemisinin in soil. Dihydroartemisinin and artemether were included in the method, and performance on analytical columns of both traditional C(18) phenyl-hexyl and porous shell particles-based Kinetex types was characterized. The versatility of the method was demonstrated on surface water and groundwater samples and plant extracts. The limit of detection was 55, 30 (25 ng/g soil), and 4 ng/mL for dihydroartemisinin, artemisinin, and artemether, respectively. Method performance was demonstrated using naturally contaminated soil samples from A. annua fields in Kenya. The highest observed concentrations were above EC(10) for lettuce growth. Monitoring of artemisinin in soil with A. annua crop production seems necessary to further understand the impact in the environment.  相似文献   

19.
The content of zearalenone and its metabolites in urine and tissue samples from pigs fed zearalenone-contaminated oats was established by analytical methods combining solid-phase extraction cleanup of the samples with highly selective liquid chromatography-mass spectrometry (LC-MS)/MS detection. Investigation of the urine samples revealed that approximately 60% of zearalenone was transformed in vivo to alpha-zearalenol and its epimer beta-zearalenol in a mean ratio of 3:1. Zeranol and taleranol as further metabolites could only be detected in trace amounts. Zearalanone was identified at considerable concentrations, though only in a couple of samples. In contrast, liver samples contained predominantly alpha-zearalenol, and to a minor extent beta-zearalenol and zearalenone, with a mean ratio of alpha-/beta-zearalenol of 2.5:1, while zeranol, taleranol, or zearalanone could not be identified in any of the investigated samples. The degree of glucoronidation was established for zearalenone as 27% in urine and 62% in liver; for alpha-zearalenol as 88% in urine and 77% in liver; and for beta-zearalenol as 94% in urine and 29% in liver. Analyses of muscle tissue revealed relatively high amounts of nonglucuronidated zeranol and alpha-zearalenol together with traces of taleranol and zearalenone, indicating that the metabolism of zearalenone and its metabolites is not restricted to hepatic and gastrointestinal metabolic pathways.  相似文献   

20.
An MS-based method, combining reversed-phase capillary liquid chromatography (capillary LC) with quadrupole time-of-flight tandem mass spectrometry (nano-ESI Q-TOF MS/MS), was developed with the aim of identifying a set of peptides that can function as markers for peanut allergens. Emphasis was given to the identification of the three major peanut allergens Ara h 1, Ara h 2, and Ara h 3, because these proteins are considered to represent >30% of the total protein content of peanut and are directly relevant for the allergenic potential of this food. The analytical data obtained were used to perform databank searching in combination with de novo sequencing and led to the identification of a multitude of sequence tags for all three peanut allergens. Food processing such as roasting of peanuts is known to affect the stability of proteins and was shown to influence the detection of allergen sequence tags. The analysis of raw and roasted peanuts allowed the identification of five peanut-specific sequence tags that can function as markers of the specific allergenic proteins. For Ara h 1, two peptide markers were proposed, namely, VLEENAGGEQEER (m/z 786.88, charge 2+) and DLAFPGSGEQVEK (m/z 688.85, charge 2+), whereas for Ara h 2 only one peptide, RQQWELQGDR (m/z 439.23, charge 3+), was found to satisfy the required conditions. For Ara h 3, the two specific peptides, SPDIYNPQAGSLK (m/z 695.35, charge 2+) and SQSENFEYVAFK (m/z 724.84, charge 2+), were selected. Other peptides have been proposed as indicative for food processing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号