首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Plasma cortisol and immunoreactive (IR)-ACTH responses to 125 micrograms of tetracosactrin and cosyntropin--the formulation of synthetic ACTH available in Europe and the United States, respectively--were compared in 10 clinically normal cats. After administration of tetracosactrin or cosyntropin, mean plasma cortisol concentration reached a peak and plateaued between 60 and 120 minutes, then gradually decreased to values not significantly different from baseline concentration by 5 hours. Mean plasma IR-ACTH concentration reached a maximal value at 15 minutes after administration of tetracosactrin or cosyntropin and was still higher than baseline concentration at 6 hours. Difference between mean plasma cortisol and IR-ACTH concentrations for the tetracosactrin or cosyntropin trials was not significant at any of the sample collection times. Individual cats had some variation in the time of peak cortisol response after administration of either ACTH preparation. About half the cats had peak cortisol concentration at 60 to 90 minutes, whereas the remainder had the peak response at 2 to 4 hours. In general, however, peak cortisol concentration in the cats with delayed response was not much higher than the cortisol concentration at 60 to 90 minutes. Overall, these results indicate that tetracosactrin or cosyntropin induce a comparable, if not identical, pattern of adrenocortical responses when administered to healthy cats.  相似文献   

2.
Serum cortisol concentrations were measured in five healthy dogs in response to five adrenocorticotropic hormone (ACTH) preparations. Cortisol concentrations were similar at time 0 (pre-ACTH) and at 30 and 60 minutes after injection of all forms of ACTH. However, at 90 and 120 minutes post-ACTH, serum cortisol concentrations were significantly lower following injection of two compounded forms of ACTH. The data showed that injection of four compounded forms of ACTH caused elevations in serum cortisol concentrations of a similar magnitude as cosyntropin in samples collected 60 minutes after administration; but concentrations at later times varied, depending on the type of ACTH used.  相似文献   

3.
OBJECTIVE: To determine whether low doses of synthetic ACTH could induce a maximal cortisol response in clinically normal dogs and to compare a low-dose ACTH stimulation protocol to a standard high-dose ACTH stimulation protocol in dogs with hyperadrenocorticism. DESIGN: Cohort study. ANIMALS: 6 clinically normal dogs and 7 dogs with hyperadrenocorticism. PROCEDURE: Each clinically normal dog was given 1 of 3 doses of cosyntropin (1, 5, or 10 micrograms/kg [0.45, 2.3, or 4.5 micrograms/lb] of body weight, i.v.) in random order at 2-week intervals. Samples for determination of plasma cortisol and ACTH concentrations were obtained before and 30, 60, 90, and 120 minutes after ACTH administration. Each dog with hyperadrenocorticism was given 2 doses of cosyntropin (5 micrograms/kg or 250 micrograms/dog) in random order at 2-week intervals. In these dogs, samples for determination of plasma cortisol concentrations were obtained before and 60 minutes after ACTH administration. RESULTS: In the clinically normal dogs, peak cortisol concentration and area under the plasma cortisol response curve did not differ significantly among the 3 doses. However, mean plasma cortisol concentration in dogs given 1 microgram/kg peaked at 60 minutes, whereas dogs given doses of 5 or 10 micrograms/kg had peak cortisol values at 90 minutes. In dogs with hyperadrenocorticism, significant differences were not detected between cortisol concentrations after administration of the low or high dose of cosyntropin. CLINICAL IMPLICATIONS: Administration of cosyntropin at a rate of 5 micrograms/kg resulted in maximal stimulation of the adrenal cortex in clinically normal dogs and dogs with hyperadrenocorticism.  相似文献   

4.
BACKGROUND: Cosyntropin (adrenocorticotropic hormone [ACTH]) stimulation tests are used to evaluate adrenal function. Low-dose ACTH stimulation tests are the most accurate method for diagnosing relative adrenal insufficiency in critically ill humans but have not been evaluated in foals. HYPOTHESIS: Peak serum cortisol concentrations in healthy foals will not be significantly different after intravenous administration of 1, 10, 100, and 250 microg of cosyntropin. ANIMALS: 14 healthy neonatal foals, 3-4 days of age. METHODS: A randomized cross-over model was used in which cosyntropin (1, 10, 100, or 250 microg) was administered intravenously on days 3 and 4 of life. Blood samples were collected before and 30, 60, 90, 120, and 150 minutes after administration of cosyntropin for determination of serum cortisol concentration. RESULTS: Serum cortisol concentrations did not significantly increase after administration of 1 microg of cosyntropin. Cortisol concentration peaked 30 minutes after administration of 10 microg of cosyntropin and 90 minutes after 100 and 250 microg of cosyntropin. There was no relationship between cosyntropin dose and serum cortisol concentration at 30 minutes. Compared with the 10-microg dose, 100 and 250 microg of cosyntropin induced significantly greater cortisol concentrations at 90 minutes, at which point the 10-microg cosyntropin-dose cortisol values were indistinguishable from baseline. There was no significant difference in the area under the cortisol concentration curve between the 100- and 250-microg doses. No effect of day of testing or foal weight on peak cortisol concentration was detected. CONCLUSIONS AND CLINICAL IMPORTANCE: The results of this study suggest that 10- and 100-microg doses of cosyntropin would be appropriate for evaluating adrenal function in neonatal foals.  相似文献   

5.
OBJECTIVE: To compare the effects of 2 doses of cosyntropin (5 microg/kg vs 250 microg, IV) on serum concentrations of cortisol, sex hormones of adrenal origin, and adrenocortical steroid intermediates and determine the optimal sample collection time after adrenal stimulation with cosyntropin. ANIMALS: 10 healthy, privately owned, neutered dogs. PROCEDURE:Dogs were randomly assigned to initially receive cosyntropin at 5 microg/kg or as a total dose of 250 microg, IV. Dogs received the alternate dose 1 to 2 weeks later. Serum was obtained from blood samples collected before (0 minutes) and 30, 60, 90, and 120 minutes after cosyntropin administration. RESULTS:Maximum stimulation of cortisol, androstenedione, progesterone, and 17-hydroxyprogesterone production was achieved at 60 minutes following IV administration of cosyntropin at 5 microg/kg or as a total dose of 250 microg. Serum estradiol concentration did not increase in response to either cosyntropin dose. For all hormones, no significant difference in serum hormone concentrations was found among sample collection times of 0, 30, 60, and 90 minutes when comparing the 2 doses of cosyntropin. CONCLUSIONS AND CLINICAL RELEVANCE: Cosyntropin, when administered at 5 microg/kg, IV, effectively stimulated maximum production of cortisol, sex hormones of adrenal origin, and adrenocortical steroid intermediates at 1 hour after administration.  相似文献   

6.
Plasma cortisol and immunoreactive (IR)-ACTH responses to 125 micrograms of synthetic ACTH (cosyntropin) administered IV or IM were compared in 10 clinically normal cats. After IM administration of cosyntropin, mean plasma cortisol concentration increased significantly (P less than 0.05) within 15 minutes, reached maximal concentration at 45 minutes, and decreased to values not significantly different from baseline concentration by 2 hours. After IV administration of cosyntropin, mean plasma cortisol concentration also increased significantly (P less than 0.05) at 15 minutes, but in contrast to IM administration, the maximal cortisol response took longer (75 minutes) and cortisol concentration remained significantly (P less than 0.05) higher than baseline cortisol concentration for 4 hours. Mean peak cortisol concentration (298 nmol/L) after IV administration of cosyntropin was significantly (P less than 0.05) higher than the peak value (248 nmol/L) after IM administration. All individual peak plasma cortisol concentrations and areas under the plasma cortisol response curve were significantly (P less than 0.05) higher after IV administration of cosyntropin than after IM administration. Mean plasma IR-ACTH concentration returned to values not statistically different from baseline by 60 minutes after IM administration of cosyntropin, whereas IR-ACTH concentration still was higher than baseline concentration 6 hours after IV administration. Peak plasma IR-ACTH concentration and area under the plasma IR-ACTH response curve also were significantly (P less than 0.05) higher after IV administration of cosyntropin. Results of the study confirmed that IV administration of cosyntropin induces significantly (P less than 0.05) greater and more prolonged adrenocortical stimulation than does IM administration.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
OBJECTIVE: To compare adrenal gland stimulation achieved following administration of cosyntropin (5 microg/kg [2.3 microg/lb]) IM versus IV in healthy dogs and dogs with hyperadrenocorticism. DESIGN: Clinical trial. Animals-9 healthy dogs and 9 dogs with hyperadrenocorticism. PROCEDURES: In both groups, ACTH stimulation was performed twice. Healthy dogs were randomly assigned to receive cosyntropin IM or IV first, but all dogs with hyperadrenocorticism received cosyntropin IV first. In healthy dogs, serum cortisol concentration was measured before (baseline) and 30, 60, 90, and 120 minutes after cosyntropin administration. In dogs with hyperadrenocorticism, serum cortisol concentration was measured before and 60 minutes after cosyntropin administration. RESULTS: In the healthy dogs, serum cortisol concentration increased significantly after administration of cosyntropin, regardless of route of administration, and serum cortisol concentrations after IM administration were not significantly different from concentrations after IV administration. For both routes of administration, serum cortisol concentration peaked 60 or 90 minutes after cosyntropin administration. In dogs with hyperadrenocorticism, serum cortisol concentration was significantly increased 60 minutes after cosyntropin administration, compared with baseline concentration, and concentrations after IM administration were not significantly different from concentrations after IV administration. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that in healthy dogs and dogs with hyperadrenocorticism, administration of cosyntropin at a dose of 5 microg/kg, IV or IM, resulted in equivalent adrenal gland stimulation.  相似文献   

8.
OBJECTIVE: To determine the lowest of 5 doses of cosyntropin (1.0, 0.5, 0.1, 0.05, or 0.01 microg/kg) administered IV that stimulates maximal cortisol secretion in clinically normal dogs. ANIMALS: 10 clinically normal dogs. PROCEDURES: 5 dose-response experiments were performed in each of the dogs. Each dog received 5 doses of cosyntropin (1.0, 0.5, 0.1, 0.05, and 0.01 microg/kg) IV in random order (2-week interval between each dose). Serum samples for determination of cortisol concentrations were obtained before (baseline) and at 10, 20, 30, 40, 50, 60, 120, and 240 minutes after cosyntropin administration. RESULTS: Compared with baseline values, mean serum cortisol concentration in the study dogs increased significantly after administration of each of the 5 cosyntropin doses. Mean peak serum cortisol concentration was significantly lower after administration of 0.01, 0.05, and 0.1 microg of cosyntropin/kg, compared with findings after administration of 0.5 and 1.0 microg of cosyntropin/kg. After administration of 0.5 and 1.0 microg of cosyntropin/kg, mean peak serum cortisol concentration did not differ significantly; higher doses of cosyntropin resulted in more sustained increases in serum cortisol concentration, and peak response developed after a longer interval. CONCLUSIONS AND CLINICAL RELEVANCE: Administration of cosyntropin IV at a dose of 0.5 microg/kg induced maximal cortisol secretion in healthy dogs. Serum cortisol concentration was reliably increased in all dogs after the administration of each of the 5 doses of cosyntropin. These data should be useful in subsequent studies to evaluate the hypothalamic-pituitary-adrenal axis in healthy and critically ill dogs.  相似文献   

9.
Plasma aldosterone concentrations were measured in response to adrenocorticotropic hormone (ACTH) gel administration in clinically normal dogs, in dogs with hypoadrenocorticism, and in dogs (with electrolyte abnormalities) that did not have hypoadrenocorticism. Baseline plasma aldosterone concentrations were determined from specimens obtained every 10 minutes for 3 hours from 2 dogs and every 30 minutes for 7.5 hours from 2 other dogs. During the evaluation period, plasma aldosterone concentrations varied by at least 50% in each dog. A randomized crossover design was used to compare changes in plasma aldosterone concentrations after administration of ACTH gel and physiologic NaCl solution. Dogs had significantly (P = 0.002) higher plasma aldosterone concentrations after administration of ACTH gel than after administration of NaCl solution. Plasma cortisol concentrations increased as expected after ACTH gel administration. Analysis of cortisol and aldosterone concentrations in the same specimens obtained at 7 sample collection times did not reveal significant linear correlation, and scatterplots did not indicate a nonlinear association. In addition, plasma aldosterone concentrations were determined in response to ACTH administration alone and to ACTH combined with a high dose of dexamethasone (0.1 mg/kg, IV). The plasma aldosterone response to ACTH alone was not significantly different from the response to ACTH combined with dexamethasone. For both tests, plasma aldosterone concentrations at 60 and 120 minutes after ACTH administration were significantly (P less than 0.0005 and P = 0.0001, respectively, increased, compared with base-line values. Six dogs with adrenocortical hypofunction, as determined by plasma cortisol concentrations before and after ACTH administration, had plasma aldosterone concentrations that were diminished or did not increase after ACTH administration.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
The utility of a low dose (1 microgram/kg) synthetic ACTH challenge test in detecting moderate reductions in adrenocortical sensitivity in dogs was examined. First, the adrenocortical responses to an intravenous bolus of either 1 microgram/kg or 0.25 mg per dog of synthetic ACTH were compared in two groups of normal dogs. While plasma cortisol concentrations were similar in both groups 60 minutes after ACTH injection, dogs given 0.25 mg ACTH showed continued elevations in plasma cortisol concentrations at 90 and 120 minutes after ACTH injection. Later, the dogs previously tested with the 1 microgram/kg ACTH challenge were given a single intramuscular dose of prednisone (2.2 mg/kg) and retested with 1 microgram/kg of ACTH one week later. Plasma cortisol levels were significantly reduced after ACTH injection in dogs previously given prednisone demonstrating that a single intramuscular prednisone dose causes detectable adrenocortical suppression one week after administration. The 1 microgram/kg synthetic ACTH challenge test provides a sensitive means for evaluating adrenocortical suppression in dogs.  相似文献   

11.
Effects of etomidate on adrenocortical function in canine surgical patients   总被引:1,自引:0,他引:1  
Adrenocortical function in canine surgical patients given etomidate at 1 of 2 dosages (1.5 mg/kg of body weight or 3 mg/kg, IV) was evaluated and compared with that of dogs given thiopental (12 mg/kg, IV). The adrenocortical function was evaluated by use of adrenocorticotropic hormone (ACTH) stimulation tests and determination of plasma cortisol concentrations at 0 minute (base line) and 60 minutes after ACTH administration. At 24 hours before administration of either drug (ie, induction of anesthesia), each dog had an increase in plasma cortisol concentration when given ACTH. The ACTH stimulation tests were repeated 2 hours after induction of anesthesia. Dogs given thiopental had base-line plasma cortisol concentrations greater than preinduction base-line values, but did not increase plasma cortisol in response to ACTH stimulation. Postinduction ACTH stimulation tests in dogs given etomidate at either dose indicated base-line and 60-minute plasma cortisol concentrations that were not different from preinduction base-line values. Therefore, adrenocortical function was suppressed 2 and 3 hours after the administration of etomidate in canine surgical patients.  相似文献   

12.
The purpose of this study was to investigate total baseline plasma cortisol and adrenocorticotropic hormone (ACTH) concentrations, and ACTH-stimulated cortisol concentrations in foals from birth to 12 wk of age. Plasma (baseline) cortisol and ACTH concentrations were measured in 13 healthy foals at birth and at 1, 2, 3, 4, 5, 7, 10, 14, 21, 28, 42, 56, and 84 d of age. Each foal received cosyntropin (0.1 μg/kg) intravenously. Plasma cortisol concentrations were measured before (baseline), and 30, and 60 min after cosyntropin administration at birth and at 3, 5, 7, 10, 14, 21, 28, 42, 56, and 84 d of age. Compared with baseline, cortisol concentration increased significantly 30 min after administration of cosyntropin on all days. Cortisol concentration was highest at birth, measured at 30 and 60 min after cosyntropin administration, compared with all other days. With the exception of birth measurements, cortisol concentration was significantly higher on day 84, measured at 30 and 60 min after cosyntropin administration, when compared with all other days. Baseline plasma ACTH was lowest at birth when compared with concentrations on days 2, 3, 4, 5, 7, 10, 14, 42, 56, and 84. Administration of 0.1 μg/kg of cosyntropin, IV, reliably induces cortisol secretion in healthy foals. Differences in the magnitude of response to cosyntropin are observed depending on the age of the foal. These data should serve as a reference for the ACTH stimulation test in foals and should be useful in subsequent studies to evaluate the hypothalamic-pituitary-adrenal axis in healthy and critically ill foals.  相似文献   

13.
Plasma cortisol responses of 19 healthy cats to synthetic ACTH and dexamethasone sodium phosphate (DSP) were evaluated. After administration of 0.125 mg (n = 5) or 0.25 mg (n = 6) of synthetic ACTH, IM, mean plasma cortisol concentrations increased significantly (P less than 0.05) at 15 minutes, reached a peak at 30 minutes, and decreased progressively to base-line values by 120 minutes. There was no significant difference (P greater than 0.05) between responses resulting from the 2 dosage rates. After administration of 1 mg of DSP/kg of body weight, IV (n = 7), mean plasma cortisol concentrations decreased at postadministration hour (PAH) 1, and were significantly lower than control cortisol concentrations at PAH 4, 6, 8, 10, and 12 (P less than 0.01). Administration of 0.1 mg of DSP/kg, IV (n = 8) or 0.01 mg of DSP/kg, IV (n = 14) induced results that were similar, but less consistent than those after the 1 mg of DSP/kg dosage. Mean plasma cortisol concentrations returned to base-line values by PAH 24. There was not a significant difference between the 3 doses (P greater than 0.05) at most times. Measurement of endogenous ACTH in 16 healthy cats revealed plasma ACTH of less than 20 to 61 pg/ml. Seemingly, administration of synthetic ACTH consistently induced a significant (P less than 0.05) adrenocortical response in healthy cats. On the basis of time-response studies, post-ACTH stimulation cortisol samples should be collected at 30 minutes after ACTH administration to ensure detection of peak adrenocortical response.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
The effect of ACTH administration on plasma cortisol concentrations in purebred and crossbred pigs was investigated. Pigs were given either 25 IU of ACTH or physiologic saline solution IM. Blood samples were collected immediately before and 1 hour after ACTH or saline solution administration. Administration of ACTH resulted in a significant (P less than 0.01) increase in plasma cortisol concentration compared with that resulting from administration of saline solution; mean values after ACTH administration were similar in both breed groups. In contrast, a fivefold range of differences was observed among individual pigs of the same age, sex, and body weight, irrespective of breed group. The type and magnitude of the adrenocortical response was consistent and repeatable in pigs over a 3-month period, suggesting that pigs have a consistent capacity for adrenocortical response to ACTH administration. Development of a dynamic test allowed the high and low responding extremes in a population to be detected. The most suitable dose of synthetic ACTH was established to be 50 IU, and the best time for blood sample collection was 60 minutes after ACTH administration. The classification of individual pigs as high or low responders was repeatable and was not affected by prior short-term exposure to ACTH.  相似文献   

15.
The plasma cortisol response to exogenous ACTH (ACTH stimulation test) was evaluated in 22 dogs with hyperadrenocorticism caused by adrenocortical neoplasia. The mean basal cortisol concentration (6.3 microgram/dl) was high, but 7 dogs had basal cortisol concentrations that were within normal range. Administration of exogenous ACTH increased the plasma cortisol concentrations in each dog. Normal post-ACTH cortisol concentrations were found in 9 (41%) of the 22 dogs; 13 (59%) had an exaggerated increase in cortisol concentrations after ACTH administration. In 9 of 13 dogs with carcinoma and in 4 of 9 with adenoma, the cortisol response was exaggerated. The mean post-ACTH cortisol concentration in the dogs with carcinoma was approximately 4 times that of the dogs with adenoma; the 7 dogs with the highest concentrations had carcinoma. Repeat studies were performed in 6 dogs 2 to 8 weeks after initial testing. In 5 of the 6 dogs, repeat testing yielded data of similar diagnostic significance. One dog, however, had an abnormally high post-ACTH cortisol concentration at initial evaluation, but had only a minimal response to ACTH administration, with a normal post-ACTH cortisol concentration, at time of resting. Although ACTH stimulation testing is useful in diagnosing hyperadrenocorticism, it can not reliably separate dogs with hyperfunction adrenocortical tumors from clinically normal dogs or from dogs with pituitary-dependent hyperadrenocorticism (bilateral adrenocortical hyperplasia).  相似文献   

16.
The objectives of this study were first to show adrenocortical response to a long‐acting adrenocorticotropic hormone preparation (tetracosactide acetate zinc suspension) (ACTH‐Z) and its effect on adrenocortical function in beef cows ( Experiment 1 ) and second to apply the ACTH‐Z challenge in dairy cows based on cortisol concentrations in milk collected at routine milking ( Experiment 2 ). In Experiment 1 , four beef cows in luteal phase were challenged with ACTH‐Z, and plasma cortisol concentrations were determined for 48 h after the injection at 30‐min to 2‐h intervals. A rapid ACTH test was conducted 3 days before and 2 h after the completion of ACTH‐Z injection for 48 h to investigate the effect on adrenocortical function. Plasma cortisol concentrations increased significantly 30 min after ACTH‐Z injection (p < 0.001), and the high cortisol levels were maintained for approximately 10 h after the injection. In Experiment 2 , eight dairy cows were subjected to ACTH‐Z challenge 1–2 weeks and 4–5 weeks post‐partum. Blood and milk samples were taken at morning and afternoon milking. All the cows showed a significant increase in cortisol concentrations in plasma as well as in skim milk 8 h after ACTH‐Z injection 1–2 weeks and 4–5 weeks post‐partum (p < 0.001). There was a significant correlation between plasma and skim milk cortisol concentrations 8 h after ACTH‐Z challenge (r = 0.74, p < 0.001). The results obtained in this study suggest that elevated levels of plasma cortisol are maintained for approximately 10 h after ACTH‐Z treatment without adverse effect on adrenocortical function and a long‐acting ACTH‐Z challenge based on cortisol concentrations in milk, which were collected at the morning and the afternoon milking, can be a useful tool to monitor adrenocortical function in cows.  相似文献   

17.
Background: Transient hypothalamic-pituitary-adrenal (HPA) axis dysfunction occurs frequently in critically ill humans and impacts survival. The prevalence and impact of HPA axis dysfunction in critically ill neonatal foals are not well characterized.
Hypotheses: (1) HPA axis dysfunction occurs in hospitalized neonatal foals, and is characterized by inappropriately low basal serum cortisol concentration or inadequate cortisol response to exogenous adrenocorticotropic hormone (ACTH); (2) hospitalized foals with HPA axis dysfunction have more severe disease and are less likely to survive than hospitalized foals with normal HPA axis function.
Animals: Seventy-two hospitalized foals and 23 healthy age-matched foals.
Methods: Basal ACTH and cortisol concentrations were measured and a paired low-dose (10 μg)/high-dose (100 μg) cosyntropin stimulation test was performed at admission in hospitalized foals. HPA axis dysfunction was defined as (1) an inappropriately low basal cortisol concentration or (2) an inadequate increase in cortisol concentration (delta cortisol) after administration of cosyntropin, with cut-off values for appropriate basal and delta cortisol concentrations determined from results obtained in healthy age-matched foals.
Results: Forty-six percent of hospitalized foals had an inappropriately low basal cortisol concentration and 52% had an inadequate delta cortisol concentration after administration of the 100 μg dose of cosyntropin. An inadequate delta cortisol response to the high (100 μg) dose of cosyntropin was significantly correlated with shock and multiple organ dysfunction syndrome in hospitalized foals, and with decreased survival in a subgroup of septic foals.
Conclusions and Clinical Importance: HPA axis dysfunction occurs frequently in hospitalized neonatal foals, and negatively impacts disease severity and survival.  相似文献   

18.
Graded dosages of cosyntropin (synthetic corticotropin) were injected into groups of normal dogs on consecutive days. On the first day, cosyntropin was administered alone and, on the second, dogs were infused with dexamethasone three hours before cosyntropin injection. Adrenocortical function was assessed by sequential measurement of plasma cortisol (hydrocortisone) concentration. While no response differences were noted to the various amounts of cosyntropin injected with or without dexamethasone pretreatment, the magnitude of adrenocortical response was significantly greater in dogs infused with dexamethasone. It is concluded that dexamethasone pretreatment renders the canine adrenal cortex more responsive to a subsequent injection of cosyntropin. The combined dexamethasone infusion-cosyntropin injection test produces consistent adrenocortical responses in normal dogs, and has potential value in evaluation of adrenopathic dogs.  相似文献   

19.
BACKGROUND: Although definitive diagnosis of hypoadrenocorticism usually is made by an adrenocorticotrophic hormone (ACTH) stimulation test using 250 microg/dog of synthetic ACTH (cosyntropin/tetracosactrin), increased costs have prompted a search for less-expensive diagnostic methods. HYPOTHESIS: A low-dose ACTH stimulation test (5 microg/kg) will distinguish between dogs with nonadrenal illness and hypoadrenocorticism. Additionally, administration of cosyntropin will not affect the results of another ACTH stimulation test performed 24 hours later. ANIMALS: Eight healthy adult dogs and 29 hospitalized dogs with suspected hypoadrenocorticism. METHODS: In this prospective study, each healthy dog received 4 ACTH stimulation tests. Dogs received either 5 microg/kg or 250 microg/dog of cosyntropin on day 1 and the alternate dose on day 2. The opposite dosing sequence was used after a 2-week washout period (days 15 and 16). Dogs with suspected Addison's disease received 2 ACTH stimulation tests, 24 hours apart, using either a dose of 5 microg/kg cosyntropin or 250 microg/dog on the 1st day and the alternate dose on the 2nd day. RESULTS: In healthy dogs, poststimulation cortisol concentrations on days 2 and 16 and days 1 and 15 were equivalent (90% confidence interval [CI]: 86.7-101.2%). In dogs with suspected Addison's disease, mean (+/-SD) cortisol responses to ACTH in the 5 microg/kg dose (16.2+/-7.7 microg/dL) and 250 microg/dog dose (15.9+/-6.3 microg/dL) were statistically equivalent (90% CI: 91.2-105.4%). CONCLUSIONS AND CLINICAL IMPORTANCE: Low-dose ACTH stimulation testing distinguishes between dogs with nonadrenal illness and hypoadrenocorticism. Additionally, the administration of 2 ACTH stimulation tests on consecutive days does not affect results of the second test.  相似文献   

20.
The serum cortisol response to intravenous synthetic ACTH (tetracosactrin) was assessed in 15 healthy adult cats. Mean cortisol levels showed a significant (P<0.001) rise at 60 minutes and peaked at 180 minutes. At 120 and 180 min- utes mean cortisol levels were significantly (P<0.001) higher than at 60 minutes. The time of peak cortisol response in individual cats varied between 120 and 240 minutes, but nine (60 per cent) peaked at 180 minutes. In response to the ACTH the cats showed a rise in cortisol levels of between 160 and 1360 per cent. No significant rise in cortisol levels was seen in five cats following administration of sterile saline.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号