1.
OBJECTIVE: To compare the mechanical properties of 4 stabilization methods for equine long-bone fractures: dynamic compression plate (DCP), limited contact-DCPlate (LC-DCP), locking compression plate (LCP), and the clamp-rod internal fixator (CRIF--formerly VetFix). STUDY DESIGN: In vitro mechanical study. SAMPLE POPULATION: Bone substitute material (24 tubes) was cut at 20 degrees to the long axis of the tube to simulate an oblique mid-shaft fracture. METHODS: Tubes were divided into 4 groups (n=6) and double plated in an orthogonal configuration, with 1 screw of 1 implant being inserted in lag fashion through the "fracture". Thus, the groups were: (1) 2 DCP implants (4.5, broad, 10 holes); (2) 2 LC-DCP implants (5.5, broad, 10 holes); (3) 2 LCP implants (4.5/5.0, broad, 10 holes) and 4 head locking screws/plate; and (4) 2 CRIF (4.5/5.0) and 10 clamps in alternating position left and right of the rod. All constructs were tested in 4-point bending with a quasi-static load until failure. The implant with the interfragmentary screw was always positioned on the tension side of the construct. Force, displacement, and angular displacement at the "fracture" line were determined. Construct stiffness under low and high loads, yield strength, ultimate strength, and maximum angular displacement were determined. RESULTS: None of the implants failed; the strength of the bone substitute was the limiting factor. At low loads, no differences in stiffness were found among groups, but LCP constructs were stiffer than other constructs under high loads (P=.004). Ultimate strength was lowest in the LCP group (P=.01), whereas yield strength was highest for LCP constructs (409 N m, P=.004). CRIF had the lowest yield strength (117 N m, P=.004); no differences in yield strength (250 N m) were found between DCP and LC-DCP constructs. Differences were found for maximum angular displacement at the "fracture" line, between groups: LPC相似文献   

2.
Objective— To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP).
Study Design— Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP.
Sample Population— Paired cadaveric canine antebrachii (n=5).
Methods— Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P <.05.
Results— HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552±0.182 N m, P =.0144 (95% confidence interval: −0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 ( P -slope=.014) and 0.8 ( P -slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively.
Conclusion— There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients.
Clinical Relevance— The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.  相似文献   

3.
Objectives: To compare in vitro monotonic biomechanical properties of an axial 3‐hole, 4.5 mm narrow locking compression plate (ELCP) using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (ELCP–TLS) with an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP–TLS) for equine proximal interphalangeal (PIP) joint arthrodesis. Design: Experimental. Animal Population: Cadaveric adult equine forelimbs (n=18 pairs). Methods: For each forelimb pair, 1 PIP joint was stabilized with an axial ELCP using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 PIP joint with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression, 6 construct pairs were tested for cyclic fatigue under axial compression, and 6 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results: Mean yield load, yield stiffness, and failure load under axial compression, single cycle to failure, of the DCP–TLS fixation were significantly greater than those of the LCP–TLS fixation. There was no significant difference between the mean number of cycles to failure in axial compression of the LCP–TLS and the DCP–TLS fixations. Mean yield load, yield stiffness, and failure load under torsion, single cycle to failure, of the LCP–TLS fixation were significantly greater than those of the DCP–TLS fixation. Conclusion: The DCP–TLS construct provided significantly greater stability under axial compression in single cycle to failure than the ELCP–TLS construct, the ELCP–TLS construct provided significantly greater stability under torsional loading in single cycle to failure than the DCP–TLS construct, and there was no significant difference in stability between the 2 constructs for cyclic loading under axial compression.  相似文献   

4.
OBJECTIVE: To compare the biomechanical characteristics and mode of failure of two different dynamic compression plate (DCP) techniques for proximal interphalangeal joint (PIPJ) arthrodesis in horses. STUDY DESIGN: Randomized block-design blocking on horse (1-5), method of fixation (two 7-hole, 3.5-mm broad DCP vs two 5-hole, 4.5-mm narrow DCP), side (left, right), and end (front, hind). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. SAMPLE POPULATION: Ten paired limbs from 5 equine cadavers. METHODS: Two 7-hole, 3.5-mm broad dynamic compression plates (bDCP) were used in 1 limb of a pair, and two 5-hole 4.5-mm narrow dynamic compression plates (nDCP) were used on the contralateral limb. Plates were positioned abaxially across the dorsomedial and dorsolateral aspect of the PIPJ. Arthrodesis constructs were loaded (19 mm/s) in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials-testing machine. Composite stiffness, yield point, and maximal bending moment at failure were obtained from bending moment-angular deformation curves. Data were analyzed using ANOVA, X(2) analysis, and Fisher's exact tests; the power of the test was calculated when differences were not significant. RESULTS: There were no significant differences in composite stiffness (P >.05; power = 0.8 @ delta = 21.9%), yield point (P >.05; power = 0.8 @ delta = 34.4%), or maximal bending moment (P >.05; power = 0.8 @ delta = 17.8%) between the two fixation techniques. For bDCP constructs, 11% (15 of 140) of the 3.5-mm screws were damaged; 7 of the screw heads pulled through plates where the plates bent, 1 screw head broke off, and 7 screws were bent or pulled out of the phalanx. For nDCP constructs, 8% (8 of 100) of the 4.5-mm screws were damaged; 1 screw head pulled through a plate, 1 screw head broke off, and 6 screws were bent or pulled out of the phalanx. CONCLUSIONS: There were no biomechanical or failure differences between bDCP and nDCP fixation of the PIPJ in horses when evaluated in single-cycle 3-point bending to failure. CLINICAL RELEVANCE: There is no biomechanical advantage to the use of two 7-hole, 3.5-mm bDCP in equine proximal interphalangeal arthrodesis compared with two 5-hole, 4.5-mm nDCP. Two 5-hole, 4.5-mm nDCP may be easier to place, whereas two 7-hole, 3.5-mm bDCP may provide more versatility in fracture repair.  相似文献   

5.
Objective— To compare monotonic biomechanical properties and fatigue life of a broad locking compression plate (LCP) fixation with a broad limited contact dynamic compression plate (LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population— Cadaveric adult equine MC3 bones (n=12 pairs). Methods— MC3 were divided into 3 groups (4 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 4.5 mm LCP was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm LC‐DCP) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment, under 4‐point bending, single cycle to failure, of the LCP fixation were significantly greater than those of the LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly greater for the LCP fixation compared with LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad LCP fixation compared with the LC‐DCP fixation. Conclusion— The 4.5 mm LCP was superior to the 4.5 mm LC‐DCP in resisting the static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for the repair of equine long bone fractures.  相似文献   

6.
OBJECTIVE: To evaluate and compare the mechanical properties of 4.5 narrow and 3.5 broad plating systems using their respective cortical and cancellous screws in unstable, central, and eccentric gap fracture models. STUDY DESIGN: Mechanical evaluation and comparison of 2 dynamic compression plate (DCP) systems. SAMPLE POPULATION: Eighteen cortical and 30 cancellous gapped fracture models. METHODS: DCP (4.5 mm narrow, 3.5 mm broad) with their respective cortical screws were applied to cortical bone density polyurethane foam blocks to construct center gap cortical fracture models that were tested in gap closing monotonic 4-point bending. DCP (4.5 mm narrow, 3.5 mm broad) with their respective cancellous screws were applied to cancellous bone density polyurethane foam blocks to construct eccentric gap cancellous fracture models. The cancellous constructs were tested in monotonic gap opening and gap closing cantilever bending and in cyclic axial loading. Univariate and multivariate repeated measures ANOVA were used to compare the maximum loads at failure of the 4.5 mm constructs and 3.5 mm constructs. RESULTS: The 4.5 mm narrow plating system withstood significantly higher loads at failure than the 3.5 mm broad plating system in 4-point bending (P<.0001) and gap opening cantilever bending (P<.0001). The 4.5 mm system failed in gap closing cantilever bending by plastic deformation of the plate, whereas the 3.5 mm system failed by screw pullout. There was no difference between the 2 systems in cyclic axial loading. CONCLUSION: Results indicate that the 4.5 mm narrow plating system has a mechanical advantage over the 3.5 mm broad plating system for stabilization of gapped fracture models. CLINICAL RELEVANCE: The 4.5 mm narrow plating system may be mechanically advantageous compared with the 3.5 mm broad plating system for stabilizing unreconstructed comminuted long bone fractures in large dogs.  相似文献   

7.
OBJECTIVE: To compare the structural properties and the interfragmentary motion in ostectomized canine femurs stabilized with either an 8-mm interlocking nail system (IN) or a 10-hole dynamic compression broad plate (DCP). ANIMAL OR SAMPLE POPULATION: Ten pairs of adult canine femurs with a 25-mm mid-diaphyseal gap. METHODS: Bone specimens were divided into 2 groups (10 femurs each). Left femurs were stabilized with a DCP and 8 bicortical screws; right femurs were stabilized with an IN and 3 screws. Mechanical tests were performed in eccentric axial loading and in craniocaudal bending. The testing was first conducted nondestructively and then until breakage. Structural properties, ie, stiffness, yield limits, and failure limits, were determined. Interfragmentary motion was measured during nondestructive tests with the use of an optoelectronic device. Axial, transverse, and rotational motions were calculated. Mean values of stiffness, yield and failure limits, and axial and shear motions for each fixation method were compared using a paired t test within each group (P <.05). RESULTS: Mean (+/-SD) values of stiffness and failure limit were significantly higher for IN constructs than for DCP constructs in compression, while there was little difference in the results between each tested group in bending. Mean yield load values were significantly higher for IN than for DCP specimens in compression as well as in bending. The axial-motion analysis revealed significant differences between IN and DCP groups during bending tests only. The highest score of transverse motion at the gap was recorded during bending tests, and was higher for DCP than for IN specimens. There were insignificant differences between the two groups with regard to rotation around the diaphyseal axis. CONCLUSIONS AND CLINICAL RELEVANCE: Structural properties and interfragmentary shear motion analysis demonstrated a much higher rigidity in the IN-bone than in the DCP-bone constructs.  相似文献   

8.
OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.  相似文献   

9.
OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.  相似文献   

10.
Objectives— To compare monotonic biomechanical properties and fatigue life of a 5.5 mm broad limited‐contact dynamic compression plate (5.5‐LC‐DCP) fixation with a 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Sample Population— Adult equine cadaveric MC3 bones (n=18 pair). Methods— MC3 were divided into 3 test groups (6 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 5.5 mm broad LC‐DCP (5.5‐LC‐DCP) was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) was applied dorsally to the contralateral bone from each pair. Plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t–test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment under 4‐point bending, single cycle to failure, of the 5.5‐LC‐DCP fixation were significantly greater (P<.024) than those of the 4.5‐LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly (P<.05) greater for the 4.5‐LC‐DCP fixation compared with the 5.5‐LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion for the 5.5‐LC‐DCP fixation was not significantly different (P>.05) than those with the 4.5‐LC‐DCP fixation. Conclusion— 5.5‐LC‐DCP fixation was superior to 4.5‐LC‐DCP fixation in resisting the static overload forces under palmarodorsal 4‐point bending. There was no significant difference between 5.5‐LC‐DCP fixation and 4.5‐LC‐DCP fixation in resisting static overload forces under torsion; however, the 5.5‐LC‐DCP offers significantly less stability (80% of that of the 4.5‐LC‐DCP) in cyclic fatigue testing. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for long bone fracture repair in horses.  相似文献   

11.
Using standard material testing techniques (bending stiffness, torsional stiffness, and maximum torque to failure or yield torque), the structural properties of interlocking nails (IN), canine femora, and IN/femur constructs were determined. Specimens that were tested included: 6 and 8 mm diameter IN with 5 to 10 screw holes (n = 18), and intact canine femora (n = 10), which also, with an IN inserted, formed the intact construct (IC) group, (n = 10). Specimens in the IC group were first tested with an 8 mm diameter IN with zero screws, followed by one and two screws (4.5 mm diameter) in the proximal and distal femur. A fracture model construct (FMC), (n = 14), consisting of a transverse femoral osteotomy with a 3 mm gap, was used with either 6 mm or 8 mm IN. In the 6 mm FMC, one and two 3.5 mm screws were used sequentially in the proximal and distal femoral segment. In the 8 mm FMC, one and two 3.5 mm screws and one and two 4.5 diameter screws were used similarly. When bending forces were applied parallel to IN screw holes, mean IN stiffness was 20% less than with forces perpendicular to the holes (n = 18), (P <.05). Eight-millimeter IN were 220% stiffer in torsion and 270% stiffer in bending than 6 mm IN (P <.05). Six-millimeter IN had approximately 32% of the bending stiffness and torsional stiffness of intact femurs (P <.05). Eight-millimeter IN had 93% and 79% of the bending stiffness and torsional stiffness, respectively, of intact femurs. Intact femur constructs (8 mm IN with four, 4.5 mm screws) had 147% of the bending stiffness (P <.05), and similar torsional stiffness and maximum torque, as intact femora (P >.05). The mean values of 6 mm FMC with four screws (3.5 mm) were 21% and 33% in torsional stiffness and bending stiffness, respectively, of intact femora values. When tested in torsion, 8 mm FMC failed by bone fracture; 6 mm FMC, in contrast, underwent plastic deformation. In comparing FMC stabilized with an 8 mm IN with two screws (4.5 mm diameter) in each bone segment, to intact femurs, the maximum torque was similar, FMC torsional stiffness was 40% (P <.05), and FMC bending stiffness was 65% (P <.05). These 8 mm FMC percentages are comparable to human IN fracture model construct values, indicating that the 8 mm IN/four screw construct should provide adequate stabilization for many canine diaphyseal femoral fractures.  相似文献   

12.
Objective: To compare the bending structural stiffness and bending strength of thick and thin 2.4 mm limited contact dynamic compression plates (2.4 LC‐DCP), 2.0 mm LC‐DCP (2.0 LC‐DCP), and 2.0 dynamic compression plates (2.0 DCP). Study Design: In vitro mechanical study. Methods: Two thicknesses of 2.4 LC‐DCP, 2.0 LC‐DCP, and 2.0 DCP stainless‐steel plates were tested in 4‐point bending. Data were collected during bending until implants plastically deformed. Bending structural stiffness and bending strength were determined from load displacement curves. Mechanical properties were compared between plates and the effects of plate type, size, and thickness on stiffness and strength were assessed using ANOVA. Results: The thick 2.4 LC‐DCP implant was the stiffest and strongest; the thin 2.0 DCP implant was most compliant and weakest. Larger sized plates, thicker plates, and limited contact design of plates enhanced stiffness and strength. For the plates studied, plate size had a larger effect than plate type or thickness on stiffness and strength. Conclusion: Increasing the size (width) and thickness of plates increases both the bending structural stiffness and strength. For the plates studied, LC‐DCP implants were stiffer and stronger than DCP implants. Clinical Relevance: Plate bending structural stiffness and strength can be most effectively enhanced by using a larger sized plate, but gains can also be achieved by using a thicker plate and/or an LC‐DCP instead of a DCP implant when possible.  相似文献   

13.
Objective — To determine the monotonic mechanical properties of osteotomized adult equine tibiae stabilized with two dynamic compression plates (DCP) and to compare the mechanical properties with those of intact tibiae and in vivo loads.
Study Design — The compressive, bending, and torsional mechanical properties of plated and intact tibiae were assessed in vitro.
Animals or Sample Population — Twelve pairs of adult equine tibiae.
Methods — Tibiae were loaded in axial compression, craniocaudal 3-point bending, or torsion in external rotation in a single cycle to failure. Mechanical properties were determined from load-displacement data.
Results — Compared to intact tibiae, the mean yield load, failure load and stiffness of plated tibiae were significantly lower ( P <.05) (compression and torsion); and the mean yield and failure bending moments, and bending stiffness, of the plated tibiae were lower ( P <.075 for yield), or significantly lower, respectively. The mean compression and bending yield loads for plated tibiae were greater than in vivo loads. The mean torsional yield load for plated tibiae approximated the torsional load determined for the adult horse at a walk.
Conclusions — Simple, anatomically reduced, DCP plated tibiae should have adequate strength to withstand immediate, postoperative in vivo compressive loads and bending moments placed on the tibia in vivo during immediate postoperative activities, however, may not have adequate torsional strength during immediate postoperative weight-bearing at a walk.
Clinical Relevance — Additional supportive methods, to decrease torsional loads, may be beneficial in maintaining stability of plate repaired tibiae during recovery from anesthesia and postoperative healing.  相似文献   

14.
OBJECTIVE: To compare the biomechanical properties of intact immature horse femurs and 3 stabilization methods in ostectomized femurs. Animal or SAMPLE POPULATION: Eighteen pairs of femurs from immature horses aged 1 to 15 months, and weighing 68 to 236 kg. METHODS: Thirty-four immature horse femurs were randomly assigned to 1 of 5 test groups: 1) interlocking intramedullary nail (IIN) (n = 6); 2) IIN with a cranial dynamic compression plate (I/DCP) (n = 6); 3) 2 dynamic compression plates (2DCP) (n = 8); 4) intact femurs tested to failure in lateromedial (LM) bending (n = 6); and 5) intact femurs tested to failure in caudocranial (CaCr) bending (n = 8). Mid-diaphyseal ostectomies (1 cm) were performed in all fixation constructs. Biomechanical testing consisted of 4 nondestructive tests: CaCr bending, LM bending, compression, and torsion, followed by bending to failure. All groups were tested to failure in LM bending with the exception of 1 group of intact femurs tested to failure in CaCr bending. Stiffness and failure properties were compared among groups. RESULTS: The 2DCP-femur construct had greater structural stiffness in nondestructive bending than the IIN-femur construct in either LM or CaCr bending, and the I/DCP-femur construct in LM bending. Only the I/DCP and 2DCP fixations were similar to intact bone in nondestructive-bending tests. In addition, the 2DCP-femur construct had greater structural and gap torsional stiffness than the I/DCP-femur construct, and greater gap torsional stiffness than the IIN-femur construct. However, all of the fixation methods tested, including the 2DCP-femur construct, had lower structural stiffness in torsional loading compared with intact bone. No significant differences in structural stiffness were found between intact bones and femur constructs tested nondestructively in compression. In resistance to LM bending to failure, the 2DCP-femur construct was superior to the IIN-femur construct, yet similar to the I/DCP-femur construct. Also, evaluation of yield and failure loads revealed no significant differences between intact bone and any of the femur constructs tested to failure in LM bending. CONCLUSIONS: In general, the 2DCP-femur construct provided superior strength and stiffness compared with the IIN and I/DCP-femur constructs under bending and torsion. CLINICAL RELEVANCE: Double plating of diaphyseal comminuted femoral fractures in immature horses may be the best method of repair, because in general, it provides the greatest strength and stiffness in bending and torsion.  相似文献   

15.
Objectives— To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP‐TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Study Design— Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Animal Population— Cadaveric adult equine forelimbs (n=18 pairs). Methods— For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0–7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results— Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP‐TLS fixation. Mean (± SD) values for the ESP and DCP‐TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 ± 8.96 and 28.5 ± 3.32 kN; stiffness, 13.11 ± 0.242 and 2.60 ± 0.17 kN/cm; and failure load, 144.4 ± 13.6 and 31.4 ± 3.8 kN. In single cycle to failure under torsion, mean (± SD) values for ESP and DCP‐TLS, respectively, were: stiffness 2,022 ± 26.2 and 107.9 ± 11.1 N m/rad; and failure load: 256.4 ± 39.2 and 87.1 ± 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 ± 65,468) was significantly greater than DCP‐TLS (95,418 ± 11,037). Conclusion— ESP was superior to an axial 3‐hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. Clinical Relevance— In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.  相似文献   

16.
Objectives— To compare (1) pullout properties between 3.5 mm cortical and locking screws, and (2) mechanical properties and gap displacements between the 3.5 mm broad limited‐contact dynamic compression plate (LC‐DCP), broad dynamic compression plate (DCP), and narrow locking compression plate (LCP), during axial loading of plate‐stabilized diaphyseal fragments with an interfragmentary gap. Study Design— In vitro mechanical testing of implanted polyurethane foam (PUF) hollow cylinders that simulated compact or osteopenic diaphyseal bone. Sample Population— (1) Five cortical and locking screws and (2) 4 PUF‐plate constructs for each plate type; using high‐ and low‐density (0.8 and 0.32 g/cm3) cylinders. Methods— (1) Screws were completely extracted at 5 mm/min. (2) Plated constructs were axially compressed at 300 N/s for 10 cycles from 5 to 355 N to determine gap displacement during physiologic loading, followed by single cycle increasing load to failure. Results— Pullout properties were not different between screw types. All plate constructs had yield loads over 3 times trotting loads. Gap closure occurred with LC‐DCP and DCP constructs, but not LCP constructs. LCP construct properties were most similar to LC‐DCP and DCP construct properties in the low‐density model. Conclusion— All plate systems sustained physiologic limb loads. Only LCP constructs maintained some gap integrity, although LC‐DCP and DCP screws were placed in neutral position. Clinical Relevance— The LCP system is more likely than LC‐DCP and DCP systems, with neutrally positioned screws, to maintain a planned interfragmentary gap, although gap strains range from 0% to 15% across the 2 mm gap during a trot load.  相似文献   

17.
Objective: To (1) compare the effect of a collateral ligament sparing surgical approach with an open surgical approach on mechanical properties of proximal interphalangeal joint (PIPJ) arthrodesis, and (2) to determine the percentage of articular cartilage surface removed by transarticular (TA) drilling with different diameter drill bits. Study Design: Randomized paired limb design. Sample Population: Cadaveric equine limbs (n=76). Methods: Cadaveric PIPJ were drilled using a 3.5, 4.5, or 5.5 mm drill bit at 80–84° to the dorsal plane to remove articular cartilage and subchondral bone from the distal articular surface of the proximal phalanx (P1) and the proximal articular surface of the middle phalanx (P2). Bone ends were photographed and the percentage of the projected surface area that was denuded of cartilage was measured. PIPJ arthrodesis constructs (3‐hole dynamic compression plate [DCP], two 5.5 mm TA screws inserted in lag fashion, medial and lateral to the DCP; DCP‐TA) were created using 2 surgical approaches in paired limbs. A conventional open approach was used in 1 limb and a collateral ligament sparing approach used in the other limb. Constructs were tested to failure in single‐cycle 3‐point dorsopalmar/plantar or lateromedial bending. Maximum load, yield load, and composite stiffness were compared between techniques. Results: The 3.5, 4.5, and 5.5 mm drill bits removed 24±4%, 35±5%, and 45±7% of total PIPJ articular cartilage surface, respectively. Constructs with the collateral ligament sparing approach had significantly greater mean yield load (11.3±2.8 versus 7.68±1.1 kN, P=.008) and mean maximum load (13.5±3.1 versus 10.1±1.94 kN, P=.02) under lateromedial bending. Under dorsopalmar/plantar bending there was no significant difference between surgical approaches. The collateral ligament sparing arthrodesis technique had a shorter surgical time (19±3 minutes) compared with the open technique (31±3 minutes). Conclusion: A collateral ligament sparing surgical approach to the PIPJ with removal of articular cartilage by TA drilling and arthrodesis by DCP‐TA was faster and stronger in mediolateral bending than arthrodesis constructs created with an open surgical approach. Clinical Relevance: Preservation of the collateral ligaments and TA drilling for cartilage removal during PIPJ arthrodesis may be a superior approach to the conventional open approach and warrants clinical evaluation.  相似文献   

18.
The objective of this study was to compare the biomechanical properties in a single cycle axial loading test and the types of failures in two constructs (a 3-hole 4.5-mm dynamic compression plate (DCP) and 7-hole 5.5-mm Y locking compression plate (Y-LCP)) in equine proximal interphalangeal joint (PIJ) arthrodesis. One limb in each pair was randomly assigned to PIJ arthrodesis using a 3-hole 4.5-mm DCP combined with two transarticular 5.5-mm cortical screws, whereas the contralateral limb was submitted to PIJ arthrodesis using a 7-hole Y-shaped 5.0-mm LCP in conjunction with one transarticular 4.5-mm cortical screw inserted through the central plate hole. Cortical screws were inserted in lag fashion. Constructs were submitted to a single axial load cycle to failure. Construct stiffness, load, and deformation were analyzed. Dynamic compression plate and Y-LCP arthrodesis constructs did not differ significantly and were equally resistant to axial loading under the conditions studied (DCP and Y-LCP group stiffness, 5685.22 N/mm and 6591.10 N/mm, respectively). Arthrodesis of the PIJ using a DCP and two transarticular 5.5-mm cortical screws or a Y-LCP yielded biomechanically equivalent outcomes under the test conditions considered. However, Y-LCP provides less impact in the palmar/plantar bone. Application of Y-LCP with unicortical screws has equivalent biomechanical characteristics of DCP and may be a safe option for PIJ arthrodesis, where potential trauma secondary to applying bicortical screws in the palmar/plantar aspect of the pastern can be avoided.  相似文献   

19.
Objectives: To compare the monotonic biomechanical properties and fatigue life of a 5.5‐mm‐broad locking compression plate (5.5 LCP) fixation with a 4.5‐mm‐broad locking compression plate (4.5 LCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. Study Design: In vitro biomechanical testing of paired cadaveric equine MC3 with a middiaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for (1) 4‐point bending single cycle to failure testing, (2) 4‐point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An 8‐hole, 5.5 LCP was applied to the dorsal surface of 1 randomly selected bone from each pair and an 8‐hole, 4.5 LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. All plates and screws were applied using standard ASIF techniques. All MC3 bones had middiaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group with significance set at P<.05. Results: Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4‐point bending, single cycle to failure, of the 5.5 LCP fixation were significantly greater than those of the 4.5 LCP fixation. Mean cycles to failure in 4‐point bending of the 5.5 LCP fixation (170,535±19,166) was significantly greater than that of the 4.5 LCP fixation (129,629±14,054). Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad 5.5 LCP fixation compared with the 4.5 LCP fixation. In single cycle to failure under torsion, the mean±SD values for the 5.5 LCP and the 4.5 LCP fixation techniques, respectively, were: yield load, 151.4±19.6 and 97.6±12.1 N m; composite rigidity, 790.3±58.1 and 412.3±28.1 N m/rad; and failure load: 162.1±20.2 and 117.9±14.6 N m. Conclusion: The 5.5 LCP was superior to the 4.5 LCP in resisting static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance: These in vitro study results may provide information to aid in selection of an LCP for repair of equine long bone fractures.  相似文献   

20.
Objectives— To compare in vitro monotonic biomechanical properties of an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP‐TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3‐TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Study Design— Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Sample Population— Cadaveric adult equine forelimbs (n=15 pairs). Methods— For each forelimb pair, 1 PIP joint was stabilized with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results— Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP‐TLS fixation were significantly greater than those of the 3‐TLS fixation. Mean cycles to failure in axial compression of the DCP‐TLS fixation was significantly greater than that of the 3‐TLS fixation. Conclusion— The DCP‐TLS was superior to the 3‐TLS in resisting the static overload forces and in resisting cyclic fatigue. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.  相似文献   