首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVE: To test the hypotheses that kinematic data of the sagittal motion of canine hind limbs during walking obtained with a 2-dimensional (2-D) system correlate well with those obtained with a 3-dimensional (3-D) system and that the data obtained with the 2-D system are repeatable. ANIMALS: 6 adult dogs with no evidence of lameness. PROCEDURES: Hind limb motions of 6 walking dogs were recorded via 2-D video and 3-D optoelectric systems simultaneously. Five valid trials were digitized, and 5 data sets (2-D 60 Hz, 3-D 180 Hz, 3-D sagittal 180 Hz, 3-D 60 Hz, and 3-D sagittal 60 Hz) of a complete gait cycle were created for each dog. In sagittal data sets, 3-D data were reduced to exclude coordinates for mediolateral orientation. Temporospatial parameters; angles of hip, stifle, and tarsal joints; and coefficients of variation of angular measurements of each dog were calculated for each data set. Accuracy of the 2-D analysis was determined by calculating mean absolute differences and estimating agreement between the 2-D and 3-D 180-Hz data sets. RESULTS: Values of joint angles and angular excursions measured with the 2-D system were repeatable and agreed with respective values obtained with the 3-D system. Reduction of the sampling rate had a greater impact on values of kinematic variables obtained with the 3-D system than did elimination of data on mediolateral orientation. CONCLUSIONS AND CLINICAL RELEVANCE: Kinematic analysis using a 2-D video system provided accurate and repeatable data of the sagittal angular motion of canine hind limbs during walking.  相似文献   

2.
OBJECTIVE: To assess intra- and interobserver repeatability of ocular biometric measurements obtained by means of high-resolution B-mode ultrasonography in dogs. Animals-6 Beagles without ocular abnormalities. PROCEDURES: B-mode ultrasonography was performed bilaterally with a 10.5-MHz broadband compact linear array transducer. All measurements were made on 2 different occasions by 2 observers. The Bland-Altman method was used to assess agreement between measurements obtained by the 2 observers and between the 2 sets of measurements obtained by each observer. RESULTS: Intra- and interobserver repeatability was highest for larger measurements, such as depth of the eye and depth of the anterior chamber. When repeatability was examined, bias was significantly different from 0 for only a few measurements, but the percentage difference between observations was as high as 180% for some measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that most measurements of intraocular distances and structures obtained by means of high-resolution B-mode ultrasonography have acceptable intra- and interobserver repeatability. However, the percentage difference between observations can be high for smaller measurements.  相似文献   

3.
Measurement of the tibial plateau slope from lateral hind-limb radiographs is a preoperative requirement when performing tibial plateau leveling osteotomy (TPLO) for repair of the cruciate-deficient stifle in dogs. Two measurements of the tibial plateau slope in 312 stifles of 156 dogs were taken from lateral radiographs by each of three observers with varying degrees of experience in the measurement method. Intraobserver variability was +/-3.4 degrees, and interobserver variability was +/-4.8 degrees. No significant differences were identified for the intraobserver measurements; however, in evaluating interobserver variability, a significant difference was found between the inexperienced observer and the two experienced observers.  相似文献   

4.
OBJECTIVE: To determine the reproducibility and accuracy of computed tomographic (CT) measurements of pituitary gland dimensions in healthy dogs. ANIMALS: 35 healthy sexually intact adult dogs. PROCEDURES: 2 observers independently viewed CT images of the skull in 35 dogs twice. Pituitary gland height, width, length, and volume and pituitary gland height-to-brain area ratio (P:B ratio) were measured or calculated. Intraobserver and interobserver agreement indexes (AIs) were calculated for pituitary gland dimensions. Computed tomography was performed also on 5 phantoms, and both observers measured phantom dimensions twice. True-value AIs were calculated for the phantom study. RESULTS: The mean +/- SD interobserver AI between observer 1 and 2 for pituitary gland height and the P:B ratio was 0.90 +/- 0.07. The intraobserver AI for pituitary gland height and the P:B ratio was 0.97 +/- 0.04 for observer 1 and 0.94 +/- 0.04 for observer 2. The intra and interobserver AIs for the other dimensions were lower than those for pituitary gland height and the P:B ratio. All phantom dimensions on CT images were underestimated significantly, compared with their true values. CONCLUSIONS AND CLINICAL RELEVANCE: The intra- and interobserver AIs for pituitary gland dimension measurements on CT images were high. However, the same observer preferably should perform serial measurements. Window settings influence pituitary gland dimension measurements, and predetermined window settings are recommended to make comparisons among dogs. Pituitary gland dimension measurements made from CT images in our study underestimated the true values.  相似文献   

5.
OBJECTIVE: To calculate normative joint angle, intersegmental forces, moment of force, and mechanical power at elbow, antebrachiocarpal, and metacarpophalangeal joints of dogs at a walk. ANIMALS: 6 clinically normal mixed-breed dogs. PROCEDURE: Kinetic data were collected via a force platform, and kinematic data were collected from forelimbs by use of 3-dimensional videography. Length, location of the center of mass, total mass, and mass moment of inertia about the center of mass were determined for each of 4 segments of the forelimb. Kinematic data and inertial properties were combined with vertical and craniocaudal ground reaction forces to calculate sagittal plane forces and moments across joints of interest throughout stance phase. Mechanical power was calculated as the product of net joint moment and the angular velocity. Joint angles were calculated directly from kinematic data. RESULTS: All joint intersegmental forces were similar to ground reaction forces, with a decrease in magnitude the more proximal the location of each joint. Flexor moments were observed at metacarpophalangeal and antebrachiocarpal joints, and extensor moments were observed at elbow and shoulder joints, which provided a net extensor support moment for the forelimb. Typical profiles of work existed for each joint. CONCLUSIONS AND CLINICAL RELEVANCE: For clinically normal dogs of a similar size at a walk, inverse dynamic calculation of intersegmental forces, moments of force, and mechanical power for forelimb joints yielded values of consistent patterns and magnitudes. These values may be used for comparison in evaluations of gait in other studies and in treatment of dogs with forelimb musculoskeletal disease.  相似文献   

6.
The repeatability of ultrasonographic measurements of the canine thyroid gland was evaluated. The variability of three different parameters (the maximal length, width, and height) within observer, between observer and between dogs was assessed based on three different measurements made by each of three observers infive healthy beagle dogs. From the three parameters, the volume of the gland was estimated using a formula of a rotation ellipse. The height and the volume had the lowest intra- and interobserver variability, while measurements of the length had the biggest intra- and interobserver variability. The mean values, with their 90% confidence interval were: height = 0.53cm [0.33-0.73], length = 2.45cm [2.04-2.85], width = 0.62cm [0.46- 0.78], volume = 0.38 cm3 [0.20-0.55].  相似文献   

7.
Movement analysis techniques allow objective and quantitative assessment of kinematic gait analysis. Consistent repeatability of the kinematic data is essential for such assessments. This study investigated whether the repeatability of a standardized Equinalysis Elite gait analysis system is sufficient to allow its use in clinical evaluation of equine lameness with reliable documentation of individual locomotion patterns. The extent to which examinations on different days affected the results when a standardized protocol was used was investigated. The repeatability of distal limb kinematics in nine sound horses over three successive days at one location was investigated. Measurements were performed at the examination area, for three motion cycles at the walk and trot, in each direction per day. Skin markers were placed on the lateral aspect of the coffin joint, forelimb fetlock joint, hindlimb fetlock joint, carpus, tarsus, elbow, and stifle, at clipped sites marked with a permanent marker. The inter-day repeatability of angular measurements of the carpus, tarsus, forelimb fetlock, and hindlimb fetlock joints was determined. A low degree of inter-day repeatability was found with statistically significant (P ≤ .05) differences between findings on different days, observed in the time-angle diagrams of left and right carpus, tarsus, forelimb fetlock, and hindlimb fetlock joints of all horses, at both walk and trot. The standardized Equinalysis Elite system for gait analysis of distal limb kinematics in the horse did not provide highly repeatable data in this setting.  相似文献   

8.
OBJECTIVE: To determine (1) the inter- and intraobserver variability in measurement of tibial plateau angle (TPA), (2) whether this inter- and intraobserver variability is related to the characteristics of the dog (age, size, and amount of degenerative joint disease [DJD]) and the experience level of the observer, and (3) the extent of any relationship between interobserver variability of TPA and the variability of the observers' selection of the specific cranial and caudal points along the tibial plateau. STUDY DESIGN: Examination of tibial radiographs of 40 dogs clinically affected with a cranial cruciate ligament (CrCL)-deficient stifle joint. METHODS: Eleven different observers, divided into 3 groups based on their level of experience with the tibial plateau leveling osteotomy (TPLO) technique, measured the TPA on all 40 radiographs on 5 different occasions. The degree of DJD present in the stifle joint was independently graded as an overall measure and then again as it specifically related to the cranial and caudal points along the tibial plateau. The total observed variabilities of the TPA were assessed with reference to interobserver differences, intraobserver differences, and among the groups of observers with respect to the different dog characteristics. Finally, the specific points selected on the radiographs were reexamined to determine whether any variability was present in cranial and caudal point selection. RESULTS: The interobserver standard deviation of the TPA measurements for each dog was 0.8 degrees, and the intraobserver standard deviation was 1.5 degrees. The TPA measurements obtained by the 11 observers differed significantly from each other (P <.001); however, there was no significant difference of TPA among the different groups of observers (P =.67). There was no significant correlation observed between either the inter- or intraobserver variability and the dog characteristics. Specific point data and their relationship to the various variables of dog characteristics and inter- and intraobserver TPA variability revealed significant correlations only to the amount of DJD present at the caudal point (P =.001). CONCLUSIONS: Interobserver variation, but no significant group variation, was present. Overall DJD did not appear to be related to the variability in TPA angle measurement. Most of the interobserver variability was attributable to variability in horizontal point selection at both the cranial and caudal points and vertical point selection at the caudal point. It appears that degenerative changes that specifically obscure the points on the tibial plateau, especially at the caudal point, are responsible for most of the interobserver variation. CLINICAL RELEVANCE: The desired postoperative TPA of 5 degrees is dependent on a precise initial measure of TPA preoperatively. This study indicates that there is statistically significant interobserver variability with measurement of TPA, which, therefore, can result in a similar amount of variability with the final tibial plateau slope obtained postoperatively.  相似文献   

9.
Objectives— To determine interobserver repeatability of measurements on computed tomography (CT) images of lax canine hip joints at different ages and in the presence of degenerative joint disease at maturity. Study Design— Longitudinal observational investigation. Animals— Sibling crossbreed hounds. Methods— Pelvic CT was performed at 20, 24, 32, 48, 68, and 104 weeks of age. Measures were performed on 3 contiguous two‐dimensional (2D) transverse CT images of both hips at each time point by 3 investigators. Center‐edge angle (CEA), horizontal toit externe angle (HTEA), ventral (VASA), dorsal (DASA), and horizontal (HASA) acetabular sector angles, acetabular index (AI), and percent femoral head coverage (CPC) were measured. Interobserver repeatability was quantified with the intraclass correlation coefficient (ICC). Satisfactory repeatability was considered when ICC≥0.75. Results— DASA, CEA, and CPC were repeatable in all age groups. HASA and HTEA were repeatable for all but 1 time point. At 20 weeks of age, all measures but AI were repeatable, and at 104 weeks of age, DASA, CEA, CPC, and HASA were repeatable. Measures were repeatable in hips with and without degenerative changes with the exceptions of AI and HASA in normal hips and VASA and HTEA in osteoarthritic hips. Conclusions— Most 2D CT measurements examined were repeatable regardless of age or joint disease. Clinical Relevance— Two‐dimensional CT measures may augment current techniques for assessing joint changes in lax canine hips.  相似文献   

10.
In this study, the observer variation and the influence of observer experience in diagnosing mitral valve prolapse in dogs was assessed by having three observers with different degrees of echocardiographic experience (10 years, 4 years, and no prior experience) analyze 303 mitral valve video recordings from 253 dogs, both with and without mitral regurgitation. To assess intraobserver variation, 16 recordings were analyzed twice, and 34 dogs were scanned twice at intervals of a few days. By consensus, 90 dogs had no mitral valve prolapse, 130 had mild and 33 had severe mitral valve prolapse. Intraobserver repeatabilities ranged from 88% to 100% and interobserver repeatabilities from 70% to 78%. In 79% to 94% of the dogs that were scanned twice, the observers diagnosed both recordings identically. All repeatabilities were reduced by approximately 10% when mitral valve prolapse was graded into mild and severe. The three observers differed significantly in diagnosing mitral valve prolapse when compared with each other in pairs (all p-values < 0.01). The unexperienced observer had the highest and most unsystematic occurrence of false diagnoses. It is possible that the interobserver repeatabilities would have been lower had each sonographer obtained his own echocardiograms. We conclude, that mitral valve prolapse in dogs can be diagnosed using two-dimensional echocardiography with the same degree of observer variation as reported in human studies, and that education and training of staff is mandatory to ensure proper ultrasonographic evaluation.  相似文献   

11.
OBJECTIVE: To assess the accuracy and reliability of a visual method of evaluating horseshoe characteristics. ANIMALS: 1,199 Thoroughbred racehorses. PROCEDURE: Characteristics of 1 forelimb horseshoe were visually assessed on horses immediately prior to racing by 5 field observers at 5 major racetracks in California. Characteristics evaluated included horseshoe type; toe grab height; and the presence of a rim, pad, and heel traction devices. Sensitivity and specificity for observer assessment of horseshoe characteristics were calculated by comparing observer assessments to a postmortem laboratory standard for horses that died within 48 hours of a race. Intraobserver agreement was assessed in a subset of horses by comparing horseshoe observations made before and after the horse's race. Interobserver agreement was evaluated by comparing horseshoe assessment among observers who examined the same subset of horses prior to racing on select days. RESULTS: The sensitivity and specificity of this visual method of evaluating horseshoe characteristics were good and ranged from 0.75 to 1 and 0.67 to 1, respectively. Agreement beyond chance (weighted kappa values) between observers and the laboratory standard for toe grab height was fair (0.60 to 0.62). Intraobserver and interobserver agreements (kappa values) were high (0.86 to 0.99 and 0.71 to 1, respectively). CONCLUSIONS AND CLINICAL RELEVANCE: Visual observation of horseshoes can be a feasible and reproducible method for assessing horseshoe characteristics prospectively in a large cohort of horses under racing conditions.  相似文献   

12.
13.
The aim of the present study was to establish which adrenal gland measurement was characterized by the least variations. To do this, we quantified the variability of seven different size measurements of the canine adrenal gland (maximal length, maximal height at the cranial and caudal poles on longitudinal and transverse images, and maximal width of the cranial and caudal poles) within observer, between observer, and between dogs based on three different measurements made by each of the three observers in six healthy Beagle dogs. The height of the caudal pole of both adrenal glands measured on longitudinal images had the lowest intra‐ and interobserver variability, while measurements of the length had the highest intra‐ and interobserver variability. Other measurements that were characterized by low intra‐ and interobserver variability were: height and width of the caudal pole on transverse images and height of the cranial pole on longitudinal images only. These results provide a basis for further study of the changes in adrenal gland size in dogs with pituitary‐dependent hyperadrenocorticism.  相似文献   

14.
Thyroid disease is common in dogs and conventional ultrasonography is a standard diagnostic test for diagnosis and treatment planning. Strain elastography can provide additional information about tissue stiffness noninvasively after applying external or internal compression. However, natural carotid artery pulsations in the canine thyroid gland are too weak to maintain sufficient internal compression force. The objective of the present study was to describe the feasibility of strain elastography for evaluating the canine thyroid gland and the repeatability of dobutamine‐induced carotid artery pulsation as an internal compression method. In seven healthy Beagle dogs, strain on each thyroid lobe was induced by external compression using the ultrasound probe and internal compression using carotid artery pulsation after dobutamine infusion. The thyroid appeared homogeneously green and the subcutaneous fat superficial to the thyroid lobe appeared blue. Strain values and strain ratios did not differ among dogs or between the left and right lobes. Interobserver repeatability was excellent for both compression methods. Intraobserver repeatability of the strain ratio measured using the carotid artery pulsation method (intraclass coefficient correlation = 0.933) was higher than that measured using the external compression method (0.760). Mean strain values of thyroid lobes for the external compression method (142.93 ± 6.67) differed from the internal method (147.31 ± 8.24; P < 0.05). Strain ratios between the two methods did not differ. Strain elastography was feasible for estimating thyroid stiffness in dogs. Carotid artery pulsation induced by dobutamine infusion can be used for canine thyroid strain elastography with excellent repeatability.  相似文献   

15.
Magnetic resonance imaging (MRI) is commonly used to diagnose degenerative lumbosacral stenosis; however, studies show limited correlation between imaging and clinical signs. The purpose of this prospective observer agreement study was to use dynamic MRI of the lumbosacral (LS) spine of healthy dogs to determine reliable reference ranges. Twenty‐two healthy large breed dogs were prospectively enrolled. MRI of the LS spine was performed in T2‐weighted, T1‐weighted, and T2‐weighted SPACE sequences in neutral, flexed, and extended positions. Four observers performed image analyses. Measurements included LS angle, vertebral canal height and area, and LS foraminal areas. Ordinal categorical assessment of loss of fat signal in the foramina, LS compression, intervertebral disc (IVD) degeneration, spondylosis, and IVD protrusion was also performed. The majority of values were significantly larger in flexion versus neutral position, and significantly smaller in extension versus neutral position (P < .05). Subclinical compression and IVD protrusion was noted in a neutral position in 45% and 55% of dogs and in an extended position in 85% and 73% of dogs, respectively. Interobserver agreement was strong (intracluster correlation coefficient [ICC] > .5) except for the L7:LS vertebral canal area ratio (ICC ≤ .03). Intraobserver agreement was high (rho > .5) for all measurements except for the mid‐L6:LS vertebral canal height ratio (rho = .38). There was poor interobserver agreement for loss of fat signal in the foramina and evidence of compression. This study provides the groundwork for future studies using dynamic MRI to evaluate dogs with signs of clinical LS disease.  相似文献   

16.
Although they are used frequently in veterinary dermatology, the reliability of canine pruritus severity scales has not been reported. The objective of this study was to evaluate the reliability of pruritus severity numerical rating scales (NRS) and pruritus severity visual analogue scales (VAS). Videos of 16 dogs were evaluated for pruritus severity by 24 observers utilizing three NRS and three VAS. Intraobserver repeatability and interobserver reproducibility were evaluated with Cohen's kappa and Kendall's rank correlation statistics, respectively. The repeatability of pruritus severity NRS was fair, with mean Cohen's weighted kappa (kappa(w)) values ranging from 0.49 to 0.60. The mean Kendall's rank correlation coefficient (t) for the three VAS ranged from 0.62 to 0.73. The reproducibility of mid-range pruritus severity ranks was poor with both scale types. Scales describing overall pruritus severity were found to be reliable most consistently. Neither NRS nor VAS displayed the degree of reliability desired in a health measurement scale. Interpretation of research results evaluating canine pruritus severity with NRS and VAS scales should account for suboptimal reliability.  相似文献   

17.
OBJECTIVE: To evaluate the effects of positioning and number of repeated measurements on intra- and interobserver variability of echocardiographic measurements in dogs. DESIGN: Prospective study. ANIMALS: 4 healthy dogs. PROCEDURE: Each observer performed 24 examinations, separately assessing each dog 6 nonconsecutive times (3 times with the dog in lateral recumbency and 3 with the dog in a standing position). Variables evaluated included M-mode measurements of left ventricular end-diastolic and left ventricular end-systolic diameters, left ventricular free-wall thickness in diastole and systole, interventricular septal thickness in diastole and systole, left ventricular shortening fraction, and 2-dimensional measurements of the left atrial diameter-to-aortic diameter ratio. RESULTS: All coefficients of variation (range, 3.4% to 26.6%) were similar between operators and positions and were < 15% for 27 of 32 values. For both operators, repeatability of the measurements was better for left ventricular end-systolic diameter, left ventricular free-wall thickness in diastole, left ventricular free-wall thickness in systole, and the left atrial diameter-to-aortic diameter in the standing position, and similar for both positions for shortening fraction and left ventricular end-diastolic diameter. No effect of cardiac cycle was observed. CONCLUSIONS AND CLINICAL RELEVANCE: Within-day variability of conventional echocardiography performed with the dog in the standing position was at least as good as that obtained with the dog in lateral recumbency for most measured variables. Single measurements of each variable may be sufficient for trained observers examining dogs that do not have an arrhythmia. The standing position should be used, particularly for stressed or dyspneic dogs.  相似文献   

18.
OBJECTIVE: To develop and evaluate a marker cluster set for measuring sagittal and extrasagittal movement of joints in the distal portion of the forelimb in ponies. ANIMALS: 4 ponies. PROCEDURES: 5 infrared cameras were positioned on a concrete walkway in a frontal-sagittal arc and calibrated. Four segments were defined: hoof, middle phalanx, proximal phalanx, and metacarpus. Rigid clusters with 4 retroreflective markers were placed on each segment. A static trial was recorded with additional anatomic markers on the medial and lateral joint lines. Those anatomic markers were removed, and kinematic data were recorded at 240 Hz during walking. An ensemble mean was computed from the 4 ponies from 5 replicates of the walks. Joint kinematic variables were calculated by use of the calibrated anatomical system technique. The design and error dispersion of each marker were evaluated. RESULTS: Marker clusters were quasiplanar, but variation in orientation error was reduced because the mean radii were > 10 times the largest error dispersion values. Measurements of sagittal rotations of the distal interphalangeal, proximal interphalangeal, and metacarpophalangeal joints were similar to measurements obtained with bone-fixed triads, but larger discrepancies between the 2 methods were found for extrasagittal rotations. CONCLUSIONS AND CLINICAL RELEVANCE: Development of noninvasive methods for quantifying data pertaining to 3-dimensional motion in horses is important for advancement of clinical analysis. The technique used in the study enabled identification of flexion-extension motions with an acceptable degree of accuracy. Appropriate correction algorithms and improvements to the technique may enable future quantification of extrasagittal motions.  相似文献   

19.
Computed tomography (CT) provides excellent bony detail, whereas magnetic resonance (MR) imaging is superior in evaluating the neural structures. The purpose of this prospective study was to assess interobserver and intermethod agreement in the evaluation of cervical vertebral column morphology and lesion severity in Great Danes with cervical spondylomyelopathy by use of noncontrast CT and high‐field MR imaging. Fifteen client‐owned affected Great Danes were enrolled. All dogs underwent noncontrast CT under sedation and MR imaging under general anesthesia of the cervical vertebral column. Three observers independently evaluated the images to determine the main site of spinal cord compression, direction and cause of the compression, articular process joint characteristics, and presence of foraminal stenosis. Overall intermethod agreement, intermethod agreement for each observer, overall interobserver agreement, and interobserver agreement between pairs of observers were calculated by use of kappa (κ) statistics. The highest overall intermethod agreements were obtained for the main site of compression and direction of compression with substantial agreements (κ = 0.65 and 0.62, respectively), whereas the lowest was obtained for right‐sided foraminal stenosis (κ = 0.39, fair agreement). For both imaging techniques, the highest and lowest interobserver agreements were recorded for the main site of compression and degree of articular joint proliferation, respectively. While different observers frequently agree on the main site of compression using both imaging techniques, there is considerable variation between modalities and among observers when assessing articular process characteristics and foraminal stenosis. Caution should be exerted when comparing image interpretations from multiple observers.  相似文献   

20.
OBJECTIVE: To quantify angular excursions; net joint moments; and powers across the stifle, tarsal, and metatarsophalangeal (MTP) joints in Labrador Retrievers and Greyhounds and investigate differences in joint mechanics between these 2 breeds of dogs. ANIMALS: 12 clinically normal dogs (6 Greyhounds and 6 Labrador Retrievers) with no history of hind limb lameness. PROCEDURE: Small retroreflective markers were applied to the skin over the pelvic limb joints, and a 4-camera kinematic system captured data at 200 Hz in tandem with force platform data while the dogs trotted on a runway. Breed-specific morphometric data were combined with kinematic and force data in an inverse-dynamics solution for stance-phase net joint moments and powers at the stifle, tarsal, and MTP joints. RESULTS: There were gross differences in kinematic patterns between Greyhounds and Labradors. At the stifle and tarsal joints, moment and power patterns were similar in shape, but amplitudes were larger for the Greyhounds. The MTP joint was a net absorber of energy, and this was greater in the Greyhounds. Greyhounds had a positive phase across the stifle, tarsal, and MTP joints at the end of stance for an active push-off, whereas for the Labrador Retrievers, the only positive phase was across the tarsus, and this was small, compared with values for the Greyhounds. CONCLUSIONS AND CLINICAL RELEVANCE: Gross differences in pelvic limb mechanics are evident between Greyhounds and Labrador Retrievers. Joint kinetics in specific dogs should be compared against breed-specific patterns.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号