首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 45 毫秒
1.
A 17-year-old spayed female domestic shorthair cat developed subcutaneous emphysema, pneumoperitoneum, and pneumoretroperitoneum during endoscopic placement of a gastrostomy feeding tube after gastric insufflation and cannula insertion. The cat underwent exploratory laparotomy to investigate the possibility of gastric rupture but only a 2- to 3-mm defect was found in the gastric fundus at the site of cannula insertion. Pasteurella multocida and Enterobacter spp were cultured aerobically from the peritoneal cavity. The cat recovered without complications.  相似文献   

2.
Objective —The purposes of this study were to develop a technique of paralumbar fossa laparoscopic ovariectomy using Endoloop ligatures and to avoid a laparotomy incision for ovary removal by using a 33–mm diameter muscle spreader trocar-cannula unit.
Animals or Sample Population —Seven mares.
Methods —Bilateral laparoscopic ovariectomy was performed under general anesthesia in two horses and under neuroleptanalgesia and local anesthesia in five standing mares. Ovaries were approached from the ipsilateral paralumbar fossa through two portal sites located in the paralumbar fossa and a third between the 17th and 18th ribs. Insufflation of the abdominal cavity was achieved using an automatic carbon dioxide insufflator. Two Endoloop ligatures were placed on the mesovarium. The cannula, located in the center of the paralumbar fossa, was removed, and a 33-mm diameter trocar-cannula unit, with a cone-shaped muscle spreader extremity, was inserted through the same portal. The mesovarium was transected between the ovary and the ligatures. The ovaries were removed from the abdomen through the 33-mm diameter cannula. The abdominal wall was closed in a routine manner.
Results —No major complications occurred during or after surgery.
Conclusion —Paralumbar fossa laparoscopic ovariectomy in mares using Endoloop ligatures and the 33-mm diameter trocar-cannula unit was an effective technique for ovariectomy of normal ovaries in this study.
Clinical Relevance —Endoloop ligatures provide a viable alternative for laparoscopic ligation of ovarian pedicles in mares.  相似文献   

3.
The feasibility of thoracoscopy for viewing the chest cavity and performing pulmonary lobectomy was assessed in 8 mongrel dogs. Previously, selective intubation had been performed in another group of dogs (n = 8) in order to monitor respiratory physiology and assess its safety. Each hemithorax was intubated using a double-barrelled endotracheal tube with one barrel placed in the left main bronchus and the other in the bifurcation of the trachea. The thoracoscope was introduced through a cannula inserted through a 2-cm incision at the ventral third of the left 5th intercostal space. The cranial, dorsal, and caudal surfaces of the pleura, lobes of the left lung, and the mediastinum were examined. A 2nd cannula was located in the dorsal 3rd of the 5th intercostal space with a prior incision and used for the introduction of forceps to separate the viscera. To biopsy, a 3rd cannula was inserted at the dorsal third of the 8th intercostal space with a prior incision, through which a 12-mm diameter stapler was introduced. Should a lobectomy be necessary, a 4th cannula is located in the middle third of the 4th intercostal space. Excision of the left caudal pulmonary lobe was performed through the incision made for the 12-mm diameter cannula (8th intercostal space); a twisting movement facilitated removal. Thoracoscopy is a procedure that can be used in dogs and is particularly suitable for examination, collection of biopsy specimens, and even lung lobectomies.  相似文献   

4.
Seventeen Gulf of Mexico sturgeons (Acipenser oxyrinchus desotoi) underwent endoscopic sex determination, gonadal biopsy, and various reproductive surgeries as part of a conservation development plan. The fish were anesthetized with tricaine methanesulfonate (MS-222) buffered with sodium bicarbonate and maintained on a recirculating water anesthesia circuit. A 6-mm Ternamian EndoTip Cannula, placed through the ventral midline, midway between pectoral and pelvic fins, permitted the introduction of a 5-mm telescope. Swim bladder aspiration and CO2 insufflation of the coelomic cavity provided excellent observation. Second and third cannulae were placed under direct visual control, lateral and cranial or caudal to the telescope cannula. Sex determination was successfully performed in all fish; however, five of 17 sturgeons (29%) required endoscopic gonadal biopsy to confirm sex. Bilateral ovariectomy or orchidectomy was successfully performed in three males and four females. Unilateral ovariectomy and bilateral ligation of the müllerian ducts using an extracorporeal suturing technique was accomplished in an additional three females. No apparent morbidity was associated with the anesthesia or endoscopic surgery in any fish. The ability to safely perform minimally invasive reproductive surgery in fish may have important management and conservation benefits.  相似文献   

5.
A 3-week-old Standardbred filly had a non-weightbearing forelimb lameness caused by scapular neck fracture. The fracture was repaired with 2 dynamic compression plates placed 90 degrees to each other. A 10-hole 4.5-mm narrow dynamic compression plate was placed on the cranial aspect of the scapular spine, and a 10-hole 3.5-mm dynamic compression plate was placed caudal to the scapular spine. One year after surgery, the filly was not lame when exercising in the pasture, and muscle atrophy was not evident on the affected limb. Eighteen months after surgery, the filly was in race training with no apparent problems caused by fracture repair.  相似文献   

6.
Collection of exocrine pancreatic secretions from cattle by use of a single-unit cannula was performed. The major advantage of the cannula was simple technical management. A small pouch of the duodenum into which the major pancreatic duct drains was formed. Continuity of the duodenum was reestablished by end-to-end anastomosis. A side arm of the cannula was inserted into the pouch to collect exocrine secretions, and the main portion of the cannula was placed cranial to the anastomosis to return pancreatic secretions to the small intestine between collection periods. The accessory pancreatic duct was ligated in 2 of 4 cattle to evaluate possible secretory contribution from this source. All cattle remained healthy after cannulation, and cattle gained approximately 100 kg of body weight in the 5 months after surgery. The mean secretory rate for exocrine pancreatic secretion in cattle was 106 +/- 6.8 ml/h. There was no effect of feeding on the pattern of secretion nor were there significant differences between cattle. A fistula formed between the pouch and duodenum approximately 120 days after surgery in the first 2 cattle used. Development of fistulas was prevented for 300 days in subsequently prepared cattle by use of surgical mesh around the cannulas, leading to functional cannulation sites. Preparation of a duodenal pouch appeared useful for long-term studies of pancreatic exocrine secretion in cattle.  相似文献   

7.
Technical note: a double L intestinal cannula for cattle   总被引:1,自引:0,他引:1  
A double L-shaped intestinal cannula was developed in an attempt to overcome problems observed previously with simple T-type cannulas. The cannula was constructed from cyclopolyvinyl chloride water pipe fittings. Construction materials were fairly rigid, but by connecting the split cannula pieces with elastic castration bands the cannula had some flexibility. Placing a short cone over the exposed cannula barrel reduced mechanical damage to the intestine. The double L cannula required a much smaller incision in the intestine during surgical insertion than a T-type cannula; it also simplified replacement. Construction is described; use and performance of the cannula has been satisfactory.  相似文献   

8.
Technical note: development of a duodenal cannula for sheep.   总被引:2,自引:0,他引:2  
A single T-shaped duodenal cannula of silicone rubber with a gutter-type small inner flange was developed for sheep. The barrel of the cannula was 24 mm long with an internal diameter of 12 mm. A polyester surgical mesh (100 mm x 100 mm) was connected to the barrel of the cannula as an anchor. Fibrous tissues grew on the polyester mesh anchor and adhered firmly to the serosa of the intestine, thus leaving no gap and, hence, preventing any leakage of intestinal contents from the side of the fistula. The small (24 mm in diameter) and thin (3 mm in thickness) outer flange of the cannula became buried in the wool and prevented any mechanical disturbance of the cannula by the activity of the animal. The elasticity of the silicone rubber prevented distortion of the duodenum around the barrel of the cannula. No erosion of the tissue between the inner flange of the cannula and the mesh was seen in postmortem observations.  相似文献   

9.
The aim of this study was to investigate the feasibility of simultaneous application of three cannulations and to test the effectiveness of a modified T-type cannula compared to simple T-type cannula. A ruminal, a simple T-type and a modified T-type duodenal and an ilial cannula were used in sheep. No complication was encountered in ruminal cannulation. Although no grafts were used, leakage of digesta was not seen for at least five months in T-type cannula and seven months in modified T-type cannula after surgery. Fibrous tissue grew between the serosa of the intestine and the peritoneum. No erosion of the tissue between intestine and body wall was observed after slaughter. Especially ilial digesta was easily obtained from modified T-type cannula.  相似文献   

10.
OBJECTIVE: To develop laparoscopic-assisted techniques for enterostomy feeding tube placement and full-thickness biopsy of the jejunum in dogs. ANIMALS: 15 healthy dogs. PROCEDURE Dogs were anesthetized, and positive pressure ventilation was provided. A trocar cannula for the laparoscope was inserted on the ventral midline caudal to the umbilicus. For enterostomy tube placement, a second trocar cannula was placed lateral to the right rectus abdominis muscle, and a Babcock forceps was used to grasp the duodenum and elevate it to the incision made for the cannula. The duodenum was sutured to the abdominal wall, and a feeding tube was inserted. For jejunal biopsy, a third trocar cannula was placed lateral to the left rectus abdominis muscle. A portion of jejunum was elevated to the incision for the second or third cannula, and a full-thickness biopsy specimen was obtained. A second specimen was obtained from another portion of jejunum, and retention sutures for the 2 biopsy sites were tied so that serosal surfaces of the biopsy sites were apposed to each other. Dogs were euthanatized 30 days after surgery. RESULTS: The enterostomy tube was properly positioned and functional in all 8 dogs that underwent laparoscopic-assisted enterostomy tube placement, and sufficient samples for histologic examination were obtained from all 7 dogs that underwent laparoscopic-assisted jejunal biopsy. None of the dogs had any identifiable problems after surgery. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that in dogs, laparoscopic-assisted procedures for enterostomy tube placement and jejunal biopsy are an acceptable alternative to procedures performed during a laparotomy.  相似文献   

11.
1.?The effects of a surgical operation, to implant a guide cannula in the chick hypothalamus for microdialysis, on behavioural responses and neural activity in broiler chicks are described.

2.?General behavioural activities (feeding, preening, sitting, drinking, cage pecking and beak wiping), open field and locomotor activity tests were conducted to evaluate the effects related to surgery in the immediate 4 d following this procedure. Perfusion of Ringer solution with high K+ after 4 d of guide cannula implantation was used to estimate the neural activity resulting from surgery through stimulation of monoamine release by in vivo brain dialysis.

3.?The results of direct behavioral observations indicated that the stress provoked by surgical guide cannula insertion caused behavioural alterations that are particularly evident in the immediate days following this procedure. Open-field tests on day 4 after surgery showed that, compared to the intact control chickens, the treated chicks had a shorter latency to ambulate and defecate, with more vocalisation. Locomotor activity was less in the treated chicks than inthe controls.

4.?After 4 d of guide cannula implantation, the serotonin concentration started to increase 30 min after the onset of perfusing high-K+ Ringer solution. It reached its highest value at one hour, suggesting that the 4 d after surgery is enough to alleviate some neurochemical dysfunction resulting from surgery. The results of behavioural observations, open-field and locomotor activity tests indicate that the surgical operation caused stress and fear in chicks which persisted up to 4 d.  相似文献   


12.
Current techniques to measure intra-abdominal pressures in horses use metal cannulas. Concerns that the metal cannula could puncture abdominal viscera if left in place prevent continual pressure measurements. The aim of this study was to validate the use of a solid microsensor and digital monitoring system in the measurement of direct intra-abdominal pressure in horses by comparing its values with the ones simultaneously obtained by means of an intraperitoneal cannula. Ten healthy adult horses had intra-abdominal pressures measured simultaneously through an intraperitoneal cannula zeroed midway between the height of the tuber ishii and point of the shoulder and by the use of an intraperitoneal solid microsensor placed within the abdomen at the same level as the metal cannula. Three repeated intra-abdominal pressure measurements were obtained at rest, after placement of a nasogastric tube, and after placement of 5-L increments of water into the stomach, up to a total volume of 20 L of water. The difference between values obtained (after conversion) was 3.6 mm Hg. The correlation coefficient was 0.825. Direct intra-abdominal pressure monitoring with a solid microsensor allows continuous monitoring without concern for gastrointestinal perforation, is simple to use and to calibrate, and is minimally invasive.  相似文献   

13.
Laparoscopic surgery is entrenched within human medicine and offers many advantages over traditional laparotomy procedures. Such techniques have filtered down into veterinary medicine, with some practitioners now routinely performing endoscopic oophorectomy in dogs. However, until the recent development of miniature laparoscopy instruments for human pediatrics, such procedures were not possible in small exotic mammals. By combining the commonly used 2.7-mm endoscopic system with 3-mm instruments, laparoscopic surgery has now become a reality in exotic mammal practice. This article summarizes the required equipment and the surgical approach to performing endoscopic oophorectomy in pet rabbits, and serves as a useful model for endosurgery in small exotic mammals.  相似文献   

14.
The surgical implantation of chronic ureter cannula to determine the renal clearance was evaluated using 24 pigs. The silicon tubing was surgically implanted into both ureters of each pigs. Two types of thick tubing (the inside diameter 1.0 or 2.5 mm and the outside diameter 4.0 mm) were used for these cannulas. The tubing was exposed out of the pig's body on the flank, on the hypogastric zone near the umbilicus, or near the groin. The following steps were effective to minimize the opportunity of a bacterial infection in the kidney and to maintain the functional integrity of the chronic ureter cannula for as longer period as possible: 1) to use the tubing of larger opening as the ureter cannula, 2) to expose the tubing from the hypogastric zone near the groin, and 3) to apply the disinfectant frequently to the incision sites, cannula outlets and pig's metabolic cage. The oral ingestion of the GGES solution increased the urinary volume, which might in turn have resulted in the effective rinsing of the kidney and the chronic ureter cannula. The cannula served satisfactorily for more than 3 weeks in 13 of the pigs, up to a maximum of 7 weeks. The PSP clearances values were low during the first week of the postoperative period, which may be attributed to surgical stress. The chronic ureter cannula, associated with the postoperative period of more than 1 week, can be recommended for the evaluation of the renal clearance of drugs in the pig.  相似文献   

15.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   

16.
An 11-year-old male Bearded Collie was brought to the Gifu University Animal Medical Centre with a skin mass on the lateral right thigh. Physical examination revealed a 30 × 65-mm oval mass with an alopecic and ulcerated surface. Histopathology of the surgically excised sample confirmed malignant trichoepithelioma. Five months after the surgery, the dog experienced lumbar pain resulting from metastasis to the lumbar vertebrae. Radiation therapy (RT) was performed and it alleviated the lumbar pain. Nine months after the surgery, multiple skin metastases were identified. RT was performed at each occurrence, which reduced the size of each tumour and resulted in a partial response; however, systemic metastasis occurred and the dog died 17 months after the initial surgery. Canine malignant trichoepithelioma is a rare tumour, so an effective treatment has not been determined. Data from our case study indicate that RT has potential for pain control of primary and metastatic malignant trichoepithelioma.  相似文献   

17.
A 2 yr old female English setter dog was admitted for acute dyspnea. The dog underwent treatment of a T9T10 thoracic vertebral fracture subluxation at the authors' institution 15 mo earlier. Upon admission, a chest X-ray revealed a pneumothorax and a metallic foreign body in the left hemithorax. An emergency video-assisted thoracoscopic surgery was successfully performed to remove a 4.6-mm long Kirschner wire that migrated from the thoracic vertebral column to the thoracic cavity. The operating time was 27 min. The dog made an uneventful recovery and was discharged on the third day after surgery. Pneumothorax should be considered in patients that develop acute dyspnea and have a history of wire fixation in the thoracic vertebral column. Video-assisted thoracoscopic surgery is a safe and effective treatment of this condition.  相似文献   

18.
In order to clarify the role of serotonin (5-HT) in the regulation of pituitary hormones, the effects of 5-HT injected into the third ventricle (3V) on prolactin (PRL) and growth hormone (GH) release were investigated in Holstein steers. A chronic cannula was implanted in 3V by stereotaxic surgery under general anesthesia. After sufficient recovery from surgery, 5-HT (0, 0.1, 1.0, 2.0 mg) was injected into via the cannula and blood samples were collected over 4 h. Plasma PRL and GH concentrations were determined by radioimmunoassay. PRL release was significantly stimulated by the injection of 5-HT. The increase in PRL was observed at 20 min after the injection at three doses and the highest dose (2.0 mg) was the most effective in stimulating PRL release. The injection of 5-HT into 3V, at all doses tested, did not alter GH release significantly. Our results suggest that 5-HT is involved in the regulation of PRL release partly through the hypothalamus in cattle.  相似文献   

19.
1. The first loop of the domestic hen's magnum was fistulated. A cannula mounted with a collecting tube served to trap the passing ova about 2.5 h following ovulation. 2. Nine out of 10 fistulated hens resumed ovulation about 2 to 5 weeks following surgery. A total of 63 magnal ova were collected. 3. Five of the magnal ova were successfully returned to the oviduct through the fistula and resulted in 5 normal soft-shelled eggs. The success of ova reimplantation was affected by prolapse of the posterior part of the oviduct and the timing of ova return.  相似文献   

20.
A Thoroughbred horse with bilateral laryngeal dysfunction was treated by placement of a long term tracheal cannula in order to restore full athletic function. The horse initially presented with right-sided arytenoid dysfunction that was considered to be due to a congenital malformation of the laryngeal cartilage. This was corrected by a right-sided laryngoplasty and ventriculectomy. The horse re-presented 1 year later with idiopathic left laryngeal hemiplegia. The decision was made to place a long-term tracheal cannula due to the low success rate and high complication rate associated with other surgeries used to correct bilateral arytenoid dysfunction. A three-piece tracheotomy cannula and stopper were positioned under general anaesthesia. The horse rapidly adjusted to the tracheal cannula and no post-surgical complications were encountered. The horse resumed training 4 weeks postoperatively. Due to the rules governing racing in Australia the horse was exported to New Zealand where he continued his racing career. It was concluded that tracheotomy is a straightforward technique associated with minimal complications and can provide an excellent prognosis for return of full airway function in racing horses. It is recognised that many issues need to be considered prior to more general acceptance of this technique, including assessment of animal welfare issues and public perception. In appropriate cases consideration should be given to using long term placement of a tracheotomy cannula as a treatment option to restore maximal airflow in horses with upper airway obstruction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号