首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Size 3-0 polydioxanone was used as a single strand, single braid (3 strands), or double braid (6 strands) to create six suture material-pattern combinations for equine tenorrhaphy: single-strand locking loop, single-braid locking loop, double-braid locking loop, single-strand three-loop pulley, single-braid three-loop pulley, and double-braid three-loop pulley. Maximum load to failure for the single-strand locking loop (46.1 +/- 2.9 newtons [N]) was less than for all other sutures (range, 103-155 N). The load required to form a 2 mm gap between tendon ends was greater for the single-braid three-loop pulley (66.7 +/- 6.9 N) and double-braid three-loop pulley (85.4 +/- 17.7 N) than any other sutures. The load required to produce a 10 mm gap was least for the single-strand locking loop (34.3 +/- 3.9 N) and greatest for the double-braid three-loop pulley (131.5 +/- 27.5 N). Gap between tendon ends at maximum load was greater for the single-braid (18.1 +/- 0.9 mm) and double-braid (19.2 +/- 2.2 mm) locking loops than for any other sutures. Suture material broke in 53% of the locking-loop tests but in only 17% of the three-loop pulley tests. Tendon matrix disruption accounted for 43% of the locking-loop failures and 77% of the three-loop pulley failures. The three-loop pulley pattern provided more support, less tendon distraction, and less tendon matrix constriction and distortion than the locking-loop pattern.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
This study compared incisional complications after ventral midline laparotomy using 2 absorbable suture materials for apposition of the linea alba in sheep. The linea alba of 93 yearling sheep was sutured by 3 veterinarians in a simple continuous pattern using either polyglactin 910 (PG910; group PG) or polydioxanone (PDS; group PD). A blinded observer assessed surgical sites at the time of suture removal. Multivariate logistic regression was used to assess the association between incisional complications and variables (suture material used, veterinarian, skin suture removal time). The odds of incisional complications did not vary significantly with the type of suture material used (P = 0.11), veterinarian (P = 0.61) or skin suture removal time (P = 0.36). Most incisional complications were cutaneous suture sinus formation. Either PG910 or PDS may be used for linea alba closure in sheep.  相似文献   

3.
Objective— To evaluate the effect of 6 different knotting methods on the mechanical properties of 3 large absorbable suture materials used in large animal surgery. Study Design— In vitro mechanical study. Sample Population— Knotted suture loops (n=15 per group). Methods— Suture loops were created between two low‐friction pulleys with either 2 polydioxanone, 2 polyglactin 910 or 3 polyglactin 910. Strands were tied using 1 of 6 knotting technique: square knot, surgeon knot, clamped surgeon's knot, sliding half‐hitch knot (HH), Delimar knot and self‐locking knot (SLK). A single cycle to failure test was performed on each suture loop with a distraction rate of 100 mm/min. Failure modes were evaluated and breaking strength, elongation to failure and stiffness were compared. Results— All loops except two HH failed at the knot by acute breaking. The double‐stranded SLK was both stronger and stiffer than all other knots for each suture material. Clamping the first throw of the surgeon knot decreased load to failure significantly (143.11 ± 8.64 N) compared with not clamping (159.21 ± 6.14 N) for polydioxanone. Stiffness and elongation to failure were respectively lower and increased for 2 polydioxanone compared with both polyglactin 910 materials for all knotting techniques. Conclusions— Knotting techniques do influence structural properties of suture loops. The double strand loop conferred stiffer and stronger properties to the SLK Clinical Relevance— Clamping the first throw of polydioxanone should be avoided when tying a suture under tension even using large diameter suture materials. Using a SLK might be considered as a useful alternative when excessive tension is present.  相似文献   

4.
Both triceps tendons and the medial collateral ligaments of both stifles of 10 freshly euthanized dogs were sharply transected. One tendon and one ligament of each dog were sutured with a three loop pulley pattern, and the opposite tendons and ligaments were sutured with a locking loop pattern. The tendons and ligaments were harvested with their muscular and bony attachments. The anastomoses were slowly tested in tension until failure occurred. The amount of tensile load required to produce failure of the anastomosis, the amount of distraction of the sutured ends prior to failure, and the modes of failure were recorded. In both tendons and ligaments, the three loop pulley pattern provided significantly greater tensile strength (p < 0.01) and allowed significantly less distraction between the sutured ends (p < 0.01) than the locking loop pattern. In tendons, disruption of the suture material was the most common mode of failure with both patterns. In ligaments, both patterns failed most commonly by pulling free from the tissue.  相似文献   

5.
Thirty-six superficial digital flexor tendons from nine fresh equine cadavers were transected and sutured with size 2 monofilament nylon. Nine tendons were repaired with each of four suture patterns: single-locking loop, double-locking loop, triple-locking loop, or three-loop pulley. The times required for application, tensile strengths, resistance to distraction (gap), and modes of failure were analyzed. The mean times required were: single-locking loop, 3 mins, 15 secs; double-locking loop, 4 mins, 15 secs; triple-locking loop, 10 mins, 50 secs; and three-loop pulley, 4 mins. The double-locking loop, triple-locking loop, and three-loop pulley suture patterns were stronger than the single-locking loop. The triple-locking loop and three-loop pulley patterns were close in strength and only the triple-locking loop was stronger than the double-locking loop. The three-loop pulley had the greatest resistance to gap formation and its mode of failure was different from the others. The three-locking loop suture patterns failed by suture breakage but the three-loop pulley failed first by suture pull-out and then by suture breakage.  相似文献   

6.
OBJECTIVE: To determine failure strength, stiffness, and failure mode of 4 suture materials in equine linea alba. STUDY DESIGN: Randomized complete block design. SAMPLE POPULATION: Linea albas collected from 12 adult horses (mean weight, 475 kg; mean age, 10 years). METHODS: The ventral abdominal fascia, including the linea alba, was collected and bisected along the linea alba into right and left halves. Each half was divided into four, 5-cm sections extending from the umbilicus cranially, and randomly assigned to 1 of 4 suture materials: 2 polydioxanone (2 PD), 3 polyglactin 910 (3 PG), 6 polyglactin 910 (6 PG), and 7 polydioxanone (7 PD). A single cycle to failure test was performed on each specimen at a distraction rate of 100 mm/min. Differences in failure strength and stiffness for the materials were evaluated using a mixed linear model with significance set at P<.05. RESULTS: In 94 of 96 test sections, constructs failed by suture failure. There were significant differences in failure strength (P<.0001) and stiffness (P<.001) among the suture/tissue constructs. 7 PD had the highest breaking strength (316.8 N) followed by 6 PG (281.3 N), 3 PG (229.9 N), and 2 PD (193.0 N). Six PG had the largest stiffness (14 N/mm) followed by 3 PG (12.7 N/mm), 7 PD (10.1 N/mm), and 2 PD (7.2 N/mm). Suture breaking strength and stiffness were not affected by linea or fascia thickness, individual horse, half of the linea alba, or abdominal wall position. Eighty-five (90.4%) suture loops failed adjacent the knot. CONCLUSIONS: When tested in single cycle to failure, suture material was more likely to fail than the linea alba. Larger suture materials had higher breaking strengths than smaller suture materials and stiffness was also affected by suture material and size. CLINICAL RELEVANCE: Given its high initial breaking strength and its relatively longer in vivo strength retention, 7 PD seems an appropriate choice of suture material for closure of the equine linea alba when maximal short-term failure strength is desired.  相似文献   

7.
Reasons for performing study: Incisional complications are a major post operative challenge following ventral midline exploratory celiotomy for abdominal pain in horses. They lead to discomfort, prolonged hospitalisation, longer recovery times and increased cost; therefore, investigation of preventative procedures are warranted. Objectives: To determine the clinical effect of antibacterial (triclosan) coated 2‐0 polyglactin 910 suture material on the likelihood of incisional infections when used for closure of subcutaneous tissue following ventral midline celiotomies in horses. Methods: One hundred horses undergoing exploratory celiotomy assigned at random to one of 2 groups. In the control group coated 2‐0 polyglactin 910 (Vicryl) was used for apposition of the subcutaneous tissue in a simple continuous pattern and, in the study group, antibacterial (triclosan) coated 2‐0 polyglactin 910 suture material (Vicryl Plus) was used. Post operatively an elastic adhesive abdominal bandage was applied, changed and the incision was inspected by a clinician blinded to the study protocol at 24–36 h and 6–9 days post operatively. Outcomes of interest were evidence of incisional pain, incisional oedema, sheath/udder oedema, incisional drainage, hernia formation and dehiscence. Results: Antibacterial‐coated suture material did not decrease the likelihood of incisional complications in 100 horses. Conclusions: A beneficial effect on ventral midline incisions in 100 horses was not evident by using antibacterial‐coated suture material. Potential relevance: Lack of effectiveness of antibacterial‐coated suture material in equine ventral midline closure after exploratory celiotomy and the observed potential adverse effects suggest that further clinical investigations are needed before using such material routinely on horses.  相似文献   

8.
OBJECTIVE: To compare a 3-loop pulley suture pattern with 2 locking-loop sutures for the repair of components of the canine Achilles mechanism. STUDY DESIGN: In vitro biomechanical study. ANIMALS: Forty-eight paired tendons collected from 9 canine cadavers. METHODS: Paired tendons were repaired with either a 3-loop pulley suture or 2 locking-loop sutures and tensile tested to failure. To ensure accurate anastomosis gap measurement a direct, non-contact, method of gap measurement, using digital video, was devised. Load initiating gap formation (defined as load at a 1 mm gap) and load producing a 3 mm gap were evaluated in addition to maximum load, gap at failure, mode of failure, and time spent placing the sutures. RESULTS: Maximum load values were similar for both repairs. The mean 1 mm gap loads were 44.0 and 18.4 N, and the mean 3 mm gap loads were 56.3 and 34.7 N, for the 3-loop pulley pattern and the 2 locking-loops, respectively; these differences were statistically significant. The 3-loop pulley pattern was faster to place and resulted in a smaller gap at failure. All but 2 repairs failed by suture pull out. CONCLUSIONS: The 3-loop pulley pattern is more resistant to gap formation during tensile loading, and is quicker to place, than 2 locking-loop sutures. CLINICAL RELEVANCE: Gap formation can significantly delay tendon healing. Tendon repairs with a gap >3 mm are reported to be at increased risk of rupture during the first 6 weeks postoperatively.  相似文献   

9.
OBJECTIVE: To evaluate closure strength (in vitro bursting pressure) of jejunal enterotomies in llamas. STUDY DESIGN: In vitro experimental study. SAMPLE POPULATION: Jejunal specimens (n=72) from 6 llamas. METHODS: Differences in bursting pressures and luminal diameters were compared between 2 layer enterotomy closures with an initial full thickness simple continuous pattern oversewn with either a continuous Lembert or Cushing suture pattern using 3 sizes (2-0, 3-0, 4-0) of polyglactin 910 and polydioxanone. RESULTS: Bursting pressures were significantly higher for enterotomies closed with polydioxanone than polyglactin 910, independent of suture size, but there was no difference between Lembert and Cushing oversew patterns. Use of a Lembert pattern reduced intestinal diameter more than a Cushing pattern regardless of suture material or size. CONCLUSIONS: Although polydioxanone resisted higher bursting pressures than polyglactin 910, both suture materials should be considered satisfactory for jejunal enterotomy closure in llamas based on typical intraluminal pressures expected in clinical patients. The optimal oversew pattern may be continuous Cushing to maximize the luminal diameter in small intestinal enterotomy closures. CLINICAL RELEVANCE: In vitro bursting pressures may help to predict which enterotomy sites would leak post-operatively, although further studies are necessary to determine the outcome in clinical patients.  相似文献   

10.
OBJECTIVE: To describe a modified 3-loop pulley suture pattern for the reattachment of canine tendons to bone along with a biomechanical comparison with the locking-loop suture. STUDY DESIGN: In vitro biomechanical study and clinical case report. ANIMALS OR SAMPLE POPULATION: Biomechanical study: 10 paired gastrocnemius tendons and calcaneii harvested from 5 canine cadavers. Case report: a Doberman with avulsion of the gastrocnemius tendon of insertion. METHODS: Biomechanical study: paired tendons were reattached to the calcaneus with either a modified 3-loop pulley pattern or a locking-loop pattern. Tensile loading to failure was performed. A direct, non-contact, method of gap measurement, using digital video, was used to measure gap formation. Load required to initiate gap formation (defined as load at a 1 mm gap) and to produce a 3 mm gap was evaluated in addition to maximum load and gap at failure. RESULTS: Mean (+/-SEM) 1 mm gap loads were 31.0+/-4.2 and 17.2+/-2.5 N, mean 3 mm gap loads were 49.1+/-2.4 and 28.9+/-3.2 N, and mean maximum loads were 72.9+/-4.3 and 55.8+/-2.2 N for the modified 3-loop pulley suture and the locking-loop suture, respectively. These differences were statistically significant (P<.05). The gap at failure was similar for both repairs. The clinical case remained sound 7 months postoperatively. CONCLUSIONS: A modified 3-loop pulley pattern is biomechanically superior to a locking-loop pattern for reattachment of the canine gastrocnemius tendon to bone and may be suitable for clinical use. CLINICAL RELEVANCE: Tendon repairs with a gap >3 mm are reported to be at increased risk of rupture during the first 6 weeks postoperatively. A modified 3-loop pulley pattern resists gap formation better than a locking-loop pattern.  相似文献   

11.
Objective: To compare the mechanical, knotting, and absorption properties of 3 synthetic absorbable suture materials (polyglactin 910, polydioxanone, poliglecaprone 25) from 2 different manufacturers (Huaiyin Medical Instruments Co. Ltd. and Ethicon Inc.). Sample Population: Suture material samples from the same manufacturing lot for each suture type and manufacturer. Methods: Part 1: 10 samples of each suture were incubated in bovine serum and tested for ultimate load and stiffness at days 0, 1, 7, 14, 21, and 28. Part 2: 10 knotted samples were similarly evaluated, without incubation. Results: Huaiyin polydioxanone had a greater (P<.001) ultimate load on days 0, 1, and 7; and a consistently greater stiffness for the duration of the study, compared with the Ethicon polydioxanone. Ethicon poliglecaprone 25 had a greater ultimate load on days 0, 1, 7 (P<.001); on day 21 Huaiyin had a greater ultimate load. Ethicon poliglecaprone had greater stiffness on days 0, 1, 7 (P<.001). Ethicon polyglactin 910 had a greater (P<.001) ultimate load at all times and a greater stiffness (P<.001) at days 0, 1, 7, and 14 compared with Huaiyin polyglactin 910. Huaiyin polydioxanone and polyglactin 910 had greater knot breaking strengths than Ethicon equivalents (P<.001). Conclusion: Differences in mechanical properties exist between nominally identical suture materials from different manufacturers.  相似文献   

12.
Objective— To describe augmentation of primary Achilles tendon repair using suture with a semitendinosus muscle flap and report outcome in 5 dogs.
Study Design— Prospective clinical study.
Animals— Dogs (n=5) with Achilles tendon rupture (n=6).
Methods— After tendon repair with #2 polypropylene in a 3-loop pulley suture pattern, the lateral one-half of the semitendinosus muscle was transected from the ischium, rotated distally then sutured with #2 polypropylene to the calcaneus in a 3-loop pulley pattern. The epitenon was sutured to the muscle flap fascia with interrupted sutures. All dogs had a bivalved cast for 2 weeks then a cranial splint for 2–6 weeks. Lameness scores (0=stands and walks normally to 4=non-weight-bearing lameness, plantigrade stance on affected pelvic limb) were determined every 2–3 weeks postoperatively for 12 weeks. Outcome was determined from telephone questionnaire of owners.
Results— Four had lameness scores of 0, the 5th had a score of 1 at 12 weeks. Three owners were very satisfied with outcome. Minor complications included cast sores (2 dogs), infection (2), and acute swelling (1); 1 major complication occurred (infection resulting in reoperation).
Conclusions— Semitendinosus flap augmentation resulted in early return to function without prolonged postoperative immobilization. Three dogs returned to full work/activity after repair.
Clinical Relevance— Augmentation of primary Achilles tendon repair with a semitendinosus flap can be considered in dogs with chronic rupture but further investigation of the long-term outcome using this technique is needed.  相似文献   

13.
OBJECTIVE: To determine a hand-tied ligature knot configuration, suture size, and suture type that would be an acceptable substitute to commercially available ligature knots for use in equine laparoscopic surgery. STUDY DESIGN: Three-factor ANOVA with the fixed effects being suture type, suture size, and knot type. The dependent variable was ligature security (load to failure). METHODS: Commercially available Endoloop and 4 hand-tied slipknot ligatures were compared with a 4-layer square knot. The hand tied ligature knots tested were the 4S modified Roeder knot, the Brooks knot, the modified Roeder knot, and the Weston knot. Two suture sizes (0, 2) of each of 2 suture types (polydioxanone, polyglactin 910) were tested with each hand tied knot. Two types (polydioxanone, polyglactin 910) of size 0 Endoloop were tested. Twenty repetitions of each knot suture type were tested for force to yield on a materials testing machine. Statistical analysis consisted of a 3-way ANOVA with individual comparisons made using the Bonferroni method. Significance was P< or = .05. RESULTS: Only the 4S modified Roeder knot in 2 polydioxanone (103 N) was comparable with the breaking strength of the square knots (157 N). All other knot suture combinations tested were significantly weaker than the square knot (range, 2-18 N). CONCLUSION: For equine laparoscopy, a 2 polydioxanone 4S modified Roeder knot would be an acceptable alternative to the commercially available Endoloop. CLINICAL RELEVANCE: Laparoscopic slip knots are commonly used in equine laparoscopic surgery. Various knot configuration and suture size and type combinations will affect the security of the slip knot.  相似文献   

14.
OBJECTIVE: To evaluate the mechanical properties of canine arytenoid cartilage-suture constructs. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Eighty canine cadaveric larynges. METHODS: Arytenoid cartilage-suture constructs were loaded to failure on a materials testing machine. The effect of hole size, suture configuration, suture size, and rate of distraction on load at failure, displacement at failure, energy to failure, and construct stiffness were evaluated. Polypropylene sutures were used exclusively. Specific variables evaluated were: (1) hole size-SH needle, 22, 20, and 18 ga hypodermic needles; (2) suture configurations-single dorsal and ventral articular sutures, double sutures, horizontal mattress, locking loop, and single non-articular sutures; (3) suture size-1, 0, 2-0, and 3-0; and (4) distraction rate-0.83 and 36.66 mm/s. RESULTS: Hole size had no effect on any biomechanical variable. Double suture and horizontal mattress configurations had the highest median load and energy at failure. Single dorsal suture configurations that did not include the arcuate crest had the lowest median load at failure. Larger suture sizes tended to result in stiffer constructs. Cartilage-suture constructs behaved in a viscoelastic manner where load at failure, energy at failure, and stiffness increased when distraction rate was increased, whereas displacement at failure did not. Most constructs failed by suture pullout regardless of distraction rate, although 50% of horizontal mattress configurations failed by avulsion of the muscular process. CONCLUSION: Suture and hole sizes appear to have few effects on the biomechanical performance of arytenoid-suture constructs. Double-suture and horizontal mattress suture patterns had the best overall mechanical properties for arytenoid lateralization. Single-suture techniques, which do not incorporate the arcuate crest, were biomechanically inferior. CLINICAL RELEVANCE: Cumbersome large-diameter sutures offer no advantage over smaller sutures when performing arytenoid lateralization. The cross-sectional geometry of the muscular process should be taken into account when placing sutures in the arytenoid cartilages. Single-suture techniques that do not incorporate the arcuate crest should be avoided.  相似文献   

15.
A Comparison of Repair Methods for Gap Healing in Equine Flexor Tendon   总被引:1,自引:0,他引:1  
In nine horses (18 forelimbs), a 3 cm section of superficial digital flexor tendon was removed and the tendons were repaired with immobilization for 6 weeks and (1) no suture (n = 6); (2) a double locking loop tenorrhaphy with carbon fiber (n = 6); or (3) a double locking loop tenorrhaphy with size 2 nylon suture (n = 6). Clinical assessment, gross evaluation, morphometry, histology, and mechanical testing were performed on two limbs from each treatment group at weeks 6, 12, and 24. At weeks 6 and 12, the unsutured tissue was less mature than the tissue sutured with nylon. By week 24, the carbon fiber repair had breaking stress (mean, 12.5 M Pa) similar to the unsutured repair (mean, 10.6 M Pa). There was necrosis and a granulomatous foreign body reaction around the carbon fiber. The nylon suture repair had significantly greater strength per unit area (mean breaking stress, 20.4 M Pa) because of a smaller area of repair tissue in the gap (mean, 3.6 cm2). At week 24, the nylon suture repair tissue was the most mature with the least inflammation of the three repair methods. A nylon double locking loop suture was the preferred method for equine flexor tenorrhaphy of a tendon gap because of greater breaking stress, histologic maturity, biocompatibility, and the adequate functional and cosmetic outcome.  相似文献   

16.
OBJECTIVE: To compare the peak force required for failure of hand-tied laparoscopic slipknot ligatures. STUDY DESIGN: In vitro mechanical evaluation of suture material/knot combinations. Sample POPULATION: Four hand-tied laparoscopic slipknots were studied. Three suture materials and 2 suture sizes were evaluated. Twenty samples of each group were tested, for a total of 400 samples. METHODS: The 4S modified Roeder, modified Roeder, and Weston and Brooks laparoscopic slipknots using 0 polyglyconate, 0 polyglycolic acid, 1 polyglyconate, and 1 polydioxanone (PDS) were tested. A vertical distracting force (5 mm/s) was applied until failure. Mean peak force to failure was obtained for each suture material, size, and knot combination. RESULTS: Mean (+/-SEM) peak force to failure of hand-tied ligatures ranged from 156.8+/-9.1 N to 4.8+/-.4 N. The 4S-modified Roeder had the highest mean peak force to failure. Ligatures tied with polyglyconate and size 1 suture had the highest mean peak force to failure. CONCLUSIONS: The 4S-modified Roeder was significantly and consistently stronger than the other slipknots. Polyglyconate was superior to other suture materials. The 1 polyglyconate had the highest mean peak force to failure followed by 0 polyglyconate that exceeded the 1PDS. CLINICAL RELEVANCE: The 4S-modified Roeder slipknot using 1 polyglyconate has the greatest breaking strength of sutures tested and should be considered when performing laparoscopic ligatures.  相似文献   

17.
OBJECTIVE: To determine the bursting strength of ventral median abdominal incisions closed by either simple continuous or inverted cruciate suture patterns. STUDY DESIGN: Experimental. ANIMAL OR SAMPLE POPULATION: Twelve equine cadavers. METHODS: A 25 cm ventral median incision was made through the linea alba and a 200 L polyurethane bladder was placed within the abdomen. Either a simple continuous or an inverted cruciate pattern using 3 polyglactin 910 with a bite size and suture interval of 1.5 cm was used to close linea incisions. Closure time was recorded for each pattern. The bladder was inflated with air at 40 L/min, and the pressure at body wall failure recorded. The length of suture used for wound closure and the wound failure modes were recorded. Deviation from the linea (cm), total suture length (cm), suture length to wound length ratio (SL:WL), closure time (min), bursting pressure (mm Hg), and failure modes were compared between groups using Welch-Aspin t-tests. The effects of independent subject variables were assessed for possible effects on bursting strength using analysis of covariance. RESULTS: Mean bursting pressure was significantly greater for the simple continuous pattern than for the inverted cruciate pattern (P = .01). Significantly less suture material (P = .0002) was required with the continuous pattern than with the inverted cruciate pattern. Mean closure time, SL:WL, deviation from the linea, and failure modes were not significantly different between groups. No significant effects were noted for independent variables in both groups on bursting strength. CONCLUSIONS: In this model, a simple continuous closure pattern for ventral median abdominal incisions was stronger than an inverted cruciate pattern. A simple continuous pattern leaves less foreign material in the wound, which may be of benefit in reducing incisional complications. CLINICAL RELEVANCE: Use of a continuous closure pattern for the linea alba may offer greater wound security during episodes of increased intra-abdominal pressure in horses.  相似文献   

18.
OBJECTIVES: To compare suture patterns (simple interrupted, modified pulley, horizontal mattress, double butterfly) by use of a novel in vitro model that quantifies force required for closure against tension. STUDY DESIGN: In vitro study. SAMPLE POPULATION: Suture constructs. METHODS: An in vitro suturing frame was constructed with extension springs to provide a standard resistance against movement of 2 panels of loops toward each other. Four different suture patterns were applied to the frame in randomized trials. The frame was affixed to a tensiometer that measured the force required for each suture pattern to close a fixed distance (3.81 cm) at a constant rate (5.08 cm/min) against the tension (0.6 kg/cm) of the extension springs. The closure distance and tension were selected subjectively to mimic tension encountered clinically during wound reconstruction oncologic surgical procedures. RESULTS: The modified pulley suture required the least force to close, followed by the double butterfly, simple interrupted, and horizontal mattress patterns. CONCLUSIONS: The modified pulley suture and double butterfly suture patterns require less force to close a given distance under tension than either simple interrupted or horizontal mattress suture patterns. CLINICAL RELEVANCE: Application of tension relieving suture techniques for fascia, subcutaneous, and buried-knot subdermal suturing should be considered to facilitate direct closure of wounds under tension. Modified pulley and double butterfly suture patterns offer some mechanical advantage by requiring less force to achieve closure compared with other suture patterns that might be used in reconstructive surgery.  相似文献   

19.
Objective— To describe a technique for, and outcome after, left‐ or right‐sided laparoscopic‐assisted nephrectomy in standing horses with unilateral renal disease. Study Design— Clinical report. Animals— Horses (n=3) with unilateral renal disease. Methods— Horses were sedated with detomidine (0.01 mg/kg intravenously [IV]) and levomethadone (0.05 mg/kg IV). Paravertebral anesthesia and infiltration‐anesthesia with 2% lidocaine were used to create a surgical field incorporating the 17th intercostal space and paralumbar fossa. Two separate, ipsilateral portals and a mini‐laparotomy were used. The perirenal peritoneum was horizontally incised (10–15 cm) using endoscissors and the incision digitally enlarged for manual dissection of the perirenal fat and kidney mobilization. The renal vessels and ureter were individually dissected, ligated, and transected under laparoscopic observation and the kidney removed. The perirenal and laparotomy peritoneal defects were not closed; and the laparotomy was closed in a multilayered fashion. The transverse abdominal muscle was apposed in a continuous pattern using 1 polyglactin 910, the subcutaneous tissue (simple continuous pattern) and skin (simple interrupted pattern) with 2–0 polyglactin 910. Results— Left (2) and right (1) sided laparoscopic‐assisted nephrectomy (1 nephrolithiasis, 2 hydronephrosis) was performed successfully. Sedation and local anesthesia was adequate for intraoperative immobilization and analgesia. No intraoperative complications occurred. Incisional seroma formation and fever occurred on days 3 and 4 in 1 horse and resolved with medical management. Conclusion— Laparoscopic‐assisted nephrectomy can be used for removal of the left or right kidney in standing horses with unilateral kidney disease. Clinical Relevance— To avoid risks associated with general anesthesia and to reduce surgical trauma, laparoscopic‐assisted nephrectomy can be performed in the standing sedated horse using a 2 portal technique and a mini‐laparotomy.  相似文献   

20.
OBJECTIVE: To compare bursting strength and failure modes of ventral median abdominal incisions closed with loop suture in a simple continuous pattern using two different suture-bite intervals. STUDY DESIGN: In vitro experiment. SAMPLE POPULATION: Equine cadavers (n=14; weighing >318 kg; postmortem interval <2 hours). METHODS: A template was used to make a 25 cm incision with suture interval and bite size of either 1.0 cm x 1.5 cm or 1.5 cm x 1.5 cm. A 200 L polyurethane bladder was inserted within the abdomen and insufflated to create abdominal wall tension. Celiotomies were closed with a #2 braided lactomer 9-1 continuous pattern with a loop suture. Deviation from the linea, closure time (minutes), total suture length (cm), suture length to wound ratio (SL:WL), bursting pressure (mm Hg), and failure modes (fascial or suture) were compared between groups using a Mann-Whitney U test. Significance was set at P<.05. RESULTS: No significant differences were identified between closing time, total suture length used, SL:WL, bursting pressure, or failure mode. Fascial failure was the main failure mode for both techniques; suture failure occurred rarely and knot failure did not occur. CONCLUSION: Based on the overall bursting pressure and failure mode, #2 braided lactomer loop suture placed in a continuous pattern should provide sufficient security for closure of the equine linea alba during recovery and the immediate postoperative period. CLINICAL RELEVANCE: Although there were no significant differences in the 2 patterns evaluated, the 1.5 cm x 1.5 cm pattern may have potential advantages for closure time, less total suture remaining in the wound, and strength.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号