首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesTo investigate the dependence of echocardiographic ratio indices (ERIs) on age, body weight (BW) and breed/study group using individually contributed and published summarized data in dogs.BackgroundERIs allow for narrow prediction intervals of M-mode echocardiographic measurements in generic adult dogs. Breed and age-specific differences have not been examined systematically using ERI methods.Animals, materials and methodsIndividual M-mode measurements were contributed by 15 published investigators from 661 dogs, allowing direct calculation of ERIs and summary statistics for each of these breed/study groups. M-mode ERI summary statistics were estimated from published summaries of 22 additional groups that included 527 adult and 36 growing dogs. Individual two-dimensional (2DE) left atrial (LA) and aortic root (Ao) measurements were contributed from 36 dogs. ERIs were analyzed for dependence on BW, breed/study group and age.ResultsThe majority of variation among ERIs was due to differences in the breed or study technique with comparatively little dependence on BW. Age dependence of ERIs was seen in the early growth phases of young dogs, but expected values for each ERI became static long before maturity, roughly at 10–12 weeks of age. ERIs derived from individual 2DE LA and Ao measurements showed no significant dependence on BW.ConclusionsERIs are well normalized for body size and may be useful for clinical evaluation of individuals, prediction of expected M-mode and 2DE cardiac dimensions, and investigation of age or breed-specific cardiac shape changes.  相似文献   

2.
3.

Introduction

Left ventricular (LV) and left atrial (LA) enlargement affect management and outcome of dogs with cardiac disease. Short-axis, two-dimensional echocardiographic (2DE) images, indexed to the aorta (Ao), are frequently used to identify cardiomegaly. Long-axis images offer complementary views of the left heart.

Animals

Eighty healthy dogs and 25 dogs with MMVD.

Methods

Healthy dogs were prospectively recruited to determine reference intervals (Clinical Laboratory Standards Institute methodology) for long-axis ratios. Measurement variability and repeatability were quantified by intraclass correlation coefficient and coefficient of variation. Mean long-axis ratios from dogs with MMVD were compared with healthy dogs (unpaired t-test). In addition, the proportion of MMVD dogs exceeding the 97.5 percentile by LV/Ao and a conventional, allometric method were compared (McNemar’s test).

Results

Two-dimensional echocardiographic long-axis reference intervals were as follows: left ventricular to aortic dimension (LV/Ao) 1.8–2.5; left atrial to aortic dimension (LA/Ao) 1.8–2.4, and left atrial to left ventricular dimension (LA/LV) 0.9–1.1. Intraobserver and interobserver measurement agreement was good-to-excellent (intraclass correlation coefficients ≥0.84), and day-to-day variability was low (coefficient of variations <4%). Left ventricular to aortic dimension, LA/Ao, and LA/LV were significantly greater in canine MMVD compared with healthy dogs (p<0.001). The percentages of MMVD dogs demonstrating LV dilatation by LV/Ao and conventional method were 68% and 36%, respectively (p=0.043, 95% confidence interval for difference 7.9%, 56.1%).

Conclusions

Simple 2DE long-axis ratios of LV/Ao, LA/Ao, and LA/LV are repeatable and demonstrate clinical utility for identifying LV and LA enlargement in dogs with MMVD.  相似文献   

4.
IntroductionAlthough challenging, predicting outcomes in dogs with myxomatous mitral valve disease (MMVD) is of importance to owners and veterinarians. Our aim was to compare the prognostic value of selected one-, two-, and three-dimensional and Doppler echocardiographic methods to predict cardiac-related and all-cause mortality in MMVD dogs. We hypothesize that three-dimensional methods would better predict prognosis than one- and two-dimensional methods.AnimalsOne-hundred thirty-eight privately-owned dogs with MMVD.Materials and methodsCox proportional Hazard analyses and Kaplan–Meier curves were used to investigate the predictive value of 14 variables; left atrial (LA) volume indexed to body weight (BW) measured by real-time three-dimensional echocardiography (RT3DE) and calculated using Simpson's modified method of discs (SMOD) and the area-length method; LA diameter in short-axis and long-axis to aortic in short-axis ratio, effective regurgitant orifice area indexed to body surface area measured in RT3DE en face view and calculated using four-chamber (4Ch) and two-chamber views alone or in combination; percentage increase in left ventricular end-diastolic and systolic internal diameters; fractional shortening; E wave velocity; regurgitant jet area/LA area.ResultsAll 14 variables were significantly predictive of cardiac-related mortality, and 11 were predictive of all-cause mortality. The prognosis was best predicted by LA volume/BW estimated by SMOD or RT3DE, consistently showing the highest predictive value in all analyses.ConclusionsLeft atrial volume calculated by SMOD showed a similar predictive value compared to RT3DE. Performing SMOD from apical 4Ch images should be considered an alternative to RT3DE for echocardiographic examinations where prognostication of disease outcome is sought.  相似文献   

5.
Introduction/ObjectivesCavalier King Charles spaniels (CKCS) are ideal candidates for longitudinal study of myxomatous mitral valve (MV) disease and stage B1 clinical trials; however, the optimization of MV measurement acquisition and repeatability must be better defined to realize this potential. Additionally, breed-specific reference ranges for CKCS MV measurements are lacking. Study objectives were to assess measurement repeatability and define optimal methods for the longitudinal study of echocardiographic MV anatomy and to define preliminary, two-dimensional echocardiographic reference ranges for MV measurements in CKCS.AnimalsForty CKCS between 10 and 24 months old.Materials and methodsPre- and post-sedation two-dimensional echocardiographic images optimized for the MV were obtained. The length, width, and area of the anterior and posterior leaflets and the diameter of the MV annulus at end-diastole and end-systole were measured. Measurement repeatability was assessed using % coefficient of variation and repeatability coefficients.ResultsIntraoperator repeatability was best for the operator with previous MV measurement experience, with comparable results for the experienced operator measuring the second operator's images, mimicking a core echocardiography laboratory setting. Except for MV annulus diameter at end-systole, sedation had no significant effect on any MV measurements, nor did it impact measurement repeatability. Preliminary, breed-specific reference ranges were defined for the population, with CKCS often noted to have a larger annular diameter at end-systole than end-diastole.ConclusionsOptimal methods for longitudinal study of the MV in CKCS have been proposed, as have two-dimensional preliminary echocardiographic reference ranges for CKCS MV measurements. The MV annulus in CKCS may differ from other breeds.  相似文献   

6.
ObjectivesTo compare dimensions and shortening fraction (SF) of the left ventricle (LV) obtained from two-dimensional (2D) and M-mode imaging of short and long-axis views.Animals40 healthy, adult German Shepherd dogs.MethodsLeft ventricular measurements were obtained using 4 echocardiographic methods: M-mode in short and long-axis and 2D imaging in short and long-axis. The methods were compared by studying the effects of imaging mode and axis on LV parameters, taking into account the influence of weight and gender.ResultsMean LV end-diastolic diameter was greater in short-axis views. However, this difference was not considered clinically relevant. Mean SF was higher when derived from 2D measurements with poor agreement among methods. A combined influence of axis, gender, and weight was observed on interventricular septal thickness in end diastole with poor agreement among methods.ConclusionsSome LV parameters were significantly affected by mode and axis, either in isolation or in combination with weight and gender, although the differences observed were not always clinically relevant. These findings show that using the different echocardiographic methods interchangeably to assess LV dimensions should be done with caution.  相似文献   

7.
Kerstin  Hansson  DVM  Jens  Häggström  DVM  PhD  Clarence  Kvart  DVM  PhD  Peter  Lord  BVSc  FRCVS 《Veterinary radiology & ultrasound》2002,43(6):568-575
Two-dimensional (2-D) echocardiographic measurement of the left atrium (LA) has the potential to be more accurate than the standard M-mode method, because the LA body can be measured. We evaluated a 2-D method for measuring LA and aorta (AO) in a right parasternal short-axis view and compared it to the M-mode method. An index for LA size (LA/AO) was calculated in 166 cavalier King Charles spaniels, 56 normal and 110 dogs with mitral regurgitation (MR) of varying degrees secondary to chronic valvular disease. In normal dogs, the AO-2-D and LA/AO-2-D did not correlate to body weight (BW) or BW2; whereas, all M-mode values and the LA-2-D were significantly (p < .05) related to both BW parameters. In normal dogs, there was no difference between M-mode and 2-D indices. For all dogs (normal and dogs with MR) there was an 11% bias between the M-mode and 2-D index with the LA/AO-2-D being higher than the LA/AO-M. The association between the mean and the difference of the indices demonstrated a quadratic relationship. Dogs with a mean LA/AO of 2.0-2.5 showed the largest difference between the two indices. Small values for the 2-D coefficients of variation for respiration and stage of diastole were found; 3.4 and 3.1%, respectively. The 2-D index is more sensitive to LA enlargement than the M-mode index.  相似文献   

8.
The objective of this retrospective study is to determine normal reference values for 2-Dimension (2D) and Motion-mode (M-mode) echocardiographic parameters in nonsedated healthy young adult Sphynx cats and to compare them to those of the domestic shorthair (DSH). 131 Sphynx cats underwent cardiac screening prior to breeding. The control group consisted of 30 healthy adult domestic cats. A complete cardiac ultrasound was performed on all cats using right parasternal long and short axis views. There were few echocardiographic parameters in the Sphynx that differed from those of the healthy DSH. Only the left atrial (LA) dimension in 2D and M-mode, the left atrial/aortic (LA/Ao) ratio and the internal dimension of the left ventricle in systole (LVIDs) measured with M-mode were different. In conclusion, although the heart of Sphynx cat can often have a particular 2-D echocardiographic appearance, the M-mode cardiac dimensions are similar to those of the DSH.  相似文献   

9.
BACKGROUND: Diagnosis of cardiomyopathy of cats is based on 2-dimensional (2D) echocardiography. However, circulating fluid volume largely determines diastolic cardiac chamber dimensions, and reduced diastolic volume in other species results in what has been called "pseudohypertrophy of the ventricular myocardium." HYPOTHESIS: Altered hydration produces changes on 2D echocardiography that may confound the diagnosis or severity assessment of cardiomyopathy of cats. ANIMALS: Ten normal colony-sourced mixed breed cats were included. METHODS: Cats were examined by echocardiography at baseline and at completion of 3 protocols (volume depletion and maintenance-rate and anesthetic-rate IV fluid administration) applied in randomized crossover design with a 6-7 day washout period. RESULTS: Volume depletion increased diastolic left ventricular interventricular septal (IVSd) and free wall diameter (4.5 +/- 0.4 to 5.8 +/- 0.6 mm; P < .001) with wall thickness exceeding 6 mm in 4 cats. Diastolic left ventricular internal diameter (LVIDd) decreased, and reduction in systolic left ventricular internal diameter (LVIDs) produced end-systolic cavity obliteration in 7 cats. Left-atrial-to-aortic-root ratio (LA: Ao, 1.4 +/- 0.2 to 1.2 +/- 0.1, P < .05) and left atrial area in diastole (LAAd) decreased with volume depletion. Maintenance-rate IV fluid administration increased LAAd and fractional shortening (FS%). Anesthetic-rate IV fluid administration increased LVIDd, FS%, LAAd, and LA:Ao ratios (to 1.7 +/- 0.1, P < .01), producing an LA: Ao ratio above normal limits in 6 cats. A systolic heart murmur developed with administration of fluid at maintenance (n = 1) and anesthetic rates (n = 6). CONCLUSIONS: Altered hydration status produces changes in the echocardiographic examination of normal cats that may lead to an erroneous diagnosis of cardiomyopathy or mask its presence. Hydration status should be considered during echocardiographic examination in cats.  相似文献   

10.
BackgroundSighthounds have high echocardiographic (ECHO) left ventricular volumes. Establishing robust breed-specific ECHO reference intervals (RI) for screening is important. End-diastolic volume index (EDVI), end-systolic volume index (ESVI) and ejection fraction (EF) reference ranges derived by Simpson's method of discs are not available for deerhounds. The influence of sex or body weight (BW) on left ventricular diameter during diastole (LVDd) and systole (LVDs) has never been reported.ObjectivesProspectively determine ECHO RI and assess prevalence of dilated cardiomyopathy (DCM) in healthy UK deerhounds.AnimalsNinety-nine deerhounds.MethodsDeerhounds scored on ECHO and ECG variables then classified as normal (NORM), equivocal (EQUIV) or affected (AFF) with DCM. Fifty-nine NORM deerhounds used to determine ECHO RI.ResultsPrevalence of DCM was 21.6%. There were significant differences in BW (P<0.001), LVDd (P<0.001) and LVDs (P<0.05) between female and male deerhounds. Cut-off values for EDVI (≥140.2 mL/m2: 79% sensitivity/97% specificity), ESVI (≥71.9 mL/m2: 94.7% sensitivity/94.2% specificity) and EF (≤42.1%: 84.2% sensitivity/92.8% specificity) were proposed to help diagnose DCM. The most reliable ECHO variables to identify AFF dogs were LVDs indexed to BW by allometric scaling and ESVI; one of the least reliable was sphericity index. Ventricular arrhythmias (VA) were identified in 13.6% of the population, with the highest prevalence in AFF deerhounds (42%).ConclusionsPreclinical DCM in deerhounds is common and VA may be associated with DCM. Healthy deerhounds have higher LVDd, LVDs and EDVI compared with other breeds. This study provides ECHO RIs for deerhounds; sex or BW RIs should be used when screening.  相似文献   

11.
The growth of the heart, relative to body weight, was measured by M-mode echocardiography in dogs during the first year of life. Echocardiographic measurements were obtained from 16 English Pointers at 1, 2, 4, and 8 weeks of age and at 3, 6, 9, and 12 months of age. Left atrial (LA), aortic (AO), left and right ventricular internal dimensions, interventricular septal and left ventricular wall thickness measurements increased in curvilinear fashion relative to increasing body weight. Least-squares regression analysis, performed on logarithmically transformed data, was used to develop power-law equations describing the relationship of echocardiographic measurements to body weight. Linear dimensions of the LA, AO, left and right ventricular internal dimensions and interventricular septal and left ventricular wall thickness changed proportionally to slightly differing exponential powers of body weight (BW), varying from 0.31 to 0.45 (BW0.31 to BW0.45). Fractional shortening and the LA to AO ratio decreased slightly, but significantly, as body weight increased. Indexing echocardiographic measurements to BW1/3 was more appropriate than indexing such measures linearly to body weight, offering a practical method for developing accurate normative graphs or tables for M-mode echocardiographic dimensions in growing dogs.  相似文献   

12.
BACKGROUND: There are few studies evaluating the natural history and prognostic variables in chronic mitral valve disease (CMVI) in a heterogeneous population of dogs. OBJECTIVES: To estimate survival and prognostic value of clinical and echocardiographic variables in dogs with CMVI of varying severity. Five hundred and fifty-eight dogs belonging to 36 breeds were studied. METHODS: Dogs were included after clinical examination and echocardiography. Long-term outcome was assessed by telephone interview with the owner. RESULTS: The mean follow-up time was 22.7 +/- 13.6 months, and the median survival time was 19.5 +/- 13.2 months. In univariate analysis, age>8 years, syncope, HR>140 bpm, dyspnea, arrhythmias, class of heart failure (International Small Animal Cardiac Health Council), furosemide therapy, end-systolic volume-index (ESV-I)>30 mL/m(2), left atrial to aortic root ratio (LA/Ao)>1.7, E wave transmitral peak velocity (Emax)>1.2 m/s, and bilateral mitral valve leaflet engagement were associated with survival time when all causes of death were included. For the cardiac-related deaths, all the previous variables except dyspnea and EDV-I>100 mL/m(2) were significantly associated with survival time. Significant variables in multivariate analysis (all causes of death) were syncope, LA/Ao>1.7 m/s, and Emax>1.2 m/s. For cardiac-related death, the only significant variable was LA/Ao>1.7. CONCLUSIONS AND CLINICAL IMPORTANCE: Mild CMVI is a relatively benign condition in dogs. However, some clinical variables can identify dogs at a higher risk of death; these variables might be useful to identify individuals that need more frequent monitoring or therapeutic intervention.  相似文献   

13.
This retrospective study reports the survival time [onset of congestive heart failure (CHF) to death from any cause] of 21 dogs with mitral regurgitation (MR) and CHF treated with a combination of furosemide, angiotensin-converting enzyme inhibitor (ACEI, benazepril, or enalapril), pimobendan, spironolactone, and amlodipine. Baseline echocardiographic data: end-systolic and end-diastolic volume indices (ESVI and EDVI), left atrium to aorta ratio (LA/Ao), and regurgitant fraction (RF) are reported. Median survival time (MST) was 430 d. Initial dosage of furosemide (P = 0.0081) and LA/Ao (P = 0.042) were negatively associated with survival. Baseline echocardiographic indices (mean ± standard deviation) were 40.24 ± 16.76 for ESVI, 161.48 ± 44.49 mL/m(2) for EDVI, 2.11 ± 0.75 for LA/Ao, and 64.71 ± 16.85% for RF. Combining furosemide, ACEI, pimobendan, spironolactone, and amlodipine may result in long survival times in dogs with MR and CHF. Severity of MR at onset of CHF is at least moderate.  相似文献   

14.
IntroductionThe objective of the study was to evaluate the accuracy of two- and three-dimensional (2D, 3D) transthoracic echocardiography (TTE), 2D transesophageal echocardiography, and computed tomography angiography (CTA) compared with cardiac magnetic resonance imaging (CMR) in normal dogs and to assess repeatability of 2D and 3D TTE for the assessment of left ventricular (LV) and left atrial (LA) dimensions.AnimalsThe study was performed on six healthy dogs.Materials and MethodsTransthoracic echocardiography, transesophageal echocardiography, CTA, and CMR were performed on each dog. Right ventricular (RV) and LV volumes (in systole and diastole), ejection fraction (EF), and LA and right atrial (RA) volumes were assessed. Repeatability and intrarater and interrater measurements of variability were quantified by average coefficient of variation (CV) for 2D and 3D TTE.ResultsNo clinically relevant differences in LV volume were detected between CMR and all modalities. Importantly, 3D TTE had the lowest CV (6.45%), correlated with (rs = 0.62, p = 0.01), and had the highest overlap in distribution with CMR (OVL >80%). Left ventricular EF and LA size via CTA compared best with CMR and RV and RA volumes were best estimated by 3D TTE. Assessment of LV and LA volumes via 3D TTE had moderate repeatability (15–21%) compared with LV M-mode measurements and 2D LA-to-aortic ratio (<10%), respectively. For LV size, interrater CV for 3D TTE (19.4%) was lower than 2D TTE (23.1%).ConclusionsMeasurements of LV, RV, and RA volumes via 3D TTE and LA volume and LV EF assessed by CTA compared best with CMR. Three-dimensional echocardiography had lower interrater and intrarater CV compared with 2D TTE.  相似文献   

15.
Background: Real‐time 3‐dimensional echocardiography (RT3D) is a recent technique based on volumetric scanning, eliminating the need for geometric modeling of the cardiac chambers and minimizing the errors caused by foreshortened views. Hypothesis: Estimations of left ventricular (LV) end‐diastolic (EDV) and end‐systolic volume (ESV), and left atrial (LA) size, differ depending on the echocardiographic technique of estimation. Animals: Fifty‐one dogs with acquired heart disease and 34 healthy control dogs. Methods: Prospective observational study by M‐mode (Teichholz method), Simpson's modified 2‐dimensional (2D) method, and RT3D methods for estimation of LV volumes. LA size was evaluated by 2D and RT3D methods. Results: RT3D showed good agreement with 2D for EDV and ESV, whereas Teichholz method overestimated LV volumes in comparison with the other 2 methods by approximately a factor 2. There were no statistically significant differences among the 3 methods in estimating ejection fraction. Comparison between RT3D assessment of LA end‐systolic volume per kilogram (LAs/kg) and LA to aortic ratio (LA/Ao) measured by 2D relative to each other showed that the RT3D method underestimated LAs/kg at lower values, and overestimated it at higher values. The difference between methods increased with increasing LA size. Conclusions and Clinical Importance: There was good agreement between RT3D and 2D methods of estimating EDV and ESV, whereas the Teichholz method overestimated LV volumes by approximately a factor 2. In comparison with RT3D, LA/Ao underestimated LA size, especially when LA was enlarged.  相似文献   

16.
The hypotheses of this prospective study were that (1) left atrial appendage (LAA) blood flow velocities can be recorded in cats with myocardial disease by transthoracic Doppler echocardiography, (2) LA enlargement, LA mechanical dysfunction, and left ventricular (LV) diastolic abnormalities are associated with decreased LAA flow velocities, and (3) low LAA flow velocities predict the appearance of spontaneous echocardiographic contrast in cats with cardiomyopathy. Transthoracic 2-dimensional, M-mode, and Doppler echocardiographic studies were performed in 89 cats with hypertrophic, restrictive, dilated, or unclassified cardiomyopathy or with hyperthyroid heart disease. Maximal LAA flow velocity (LAAmax) was decreased (P < .001) in cats with cardiomyopathy (median, 0.28 m/s; range, 0.08-1.35) compared to normal cats. Associated with decreased LAA flow velocities were increased LA size, decreased LA function, increased severity of LV diastolic dysfunction, and the presence of congestive heart failure. Multivariate logistic regression analysis detected an LAAmax <0.20 m/s as the only independent variable to predict LA spontaneous echocardiographic contrast (odds ratio, 30.1; 95% confidence interval [CI], 4.1 222.3; P < .001). Receiver operating characteristic analysis performed to predict spontaneous echocardiographic contrast indicated an area under the curve of 0.88 (95% CI, 0.80-0.95; P < .001) with sensitivities of 100 and 74% and specificities of 69 and 83% for LAAmax <0.25 and <0.20 m/s, respectively. Thus, low LAA flow velocities identified a subgroup of patients at increased risk of spontaneous echocardiographic contrast and possible thromboembolism. These findings may have important clinical implications for anticoagulation therapy and prognostication in cats with cardiomyopathy.  相似文献   

17.
ObjectiveTo evaluate the physiological variables, arterial blood gas values, induction of anesthesia quality, and recovery quality using the combination of butorphanol, midazolam and alfaxalone in dogs.AnimalsTen healthy adult Beagle dogs weighing 8.3 ± 3.1 kg.MethodsRectal temperature (T), pulse rate (PR), respiratory rate (fR), mean arterial pressure (MAP), and arterial blood gases were measured and recorded prior to intravenous (IV) administration of butorphanol, prior to administration of both midazolam and alfaxalone IV 10 minutes later, then every 5 minutes for 20 minutes. M-mode echocardiographic left ventricular (LV) indices were measured before and 5 minutes after administration of alfaxalone. Qualitative scores for induction of anesthesia and recovery were allocated, duration of anesthesia and recovery were calculated, and adverse events were recorded.ResultsScores for induction and recovery quality were excellent. No significant adverse events were observed. Mean ± SD time from induction to extubation and to standing (full recovery) was 29 ± 6 and 36 ± 8 minutes, respectively. There were statistically significant changes in PR, fR and MAP after drug administration. Transient hypercarbia developed after alfaxalone injection. The echocardiographic LV indices were reduced after alfaxalone injection, although those changes were not statistically significant.Conclusions and clinical relevanceThe combination of butorphanol, midazolam and alfaxalone provided excellent quality of induction of anesthesia and exerted minimal cardiopulmonary effects in healthy dogs.  相似文献   

18.
BackgroundInformation regarding changes in renin‐angiotensin‐aldosterone system (RAAS) during cardiac remodeling after mitral valvuloplasty (MVP) in dogs remains lacking.Hypothesis/ObjectivesTo assess the longitudinal effects of MVP on circulating RAAS activity.AnimalsEight client‐owned dogs receiving MVP for myxomatous mitral valve disease (MMVD).MethodsThis is a cohort study. Plasma renin activity (PRA), angiotensin II (AT2), aldosterone (PAC), blood urea nitrogen (BUN), and creatinine concentrations, were measured in these dogs before (baseline) and at 3 consecutive monthly follow‐ups (Post‐1M, Post‐2M, Post‐3M). Echocardiography was concomitantly used to assess the process of cardiac recovery after MVP.ResultsThe echocardiography revealed a significant decrease in LVIDDN, LA/Ao, FS, E velocity, E/A, E′ sep, S′ lat, E′ lat, and A′ lat after MVP compared with baseline (P < .05). There was a significant reduction in the PRA (2.45, 3.05, 2.74 vs 8.8 ng/mL/h; P = .002), AT2 (466, 315, 235 vs 1200 pg/mL; P = .009), and PAC (39.88, 47, 54.62 vs 179.5 pg/mL; P = .01), respectively at Post‐1M, Post‐2M, Post‐3M compared to the baseline. Additionally, BUN and creatinine concentrations decreased from Post‐1M. The RAAS variables showed significant, weak to moderate, relationship with selected echocardiographic variables.Conclusions and Clinical ImportanceMitral valvuloplasty contributes to decreased RAAS activity in MMVD dogs, which paralleled the process of cardiac reverse remodeling up to Post‐3M. This information facilitates formulating strategies to optimize clinical outcomes for dogs after MVP.  相似文献   

19.
M-mode and Doppler echocardiographic values were obtained from 30 normal adult ferrets (14 neutered females, 13 neutered males, 3 intact males) sedated with an intramuscular combination of ketamine hydrochloride and midazolam. Routine M-mode measurements of the left and right ventricle, left atrium (LA) and aorta (AO) and Doppler measurements of aortic and pulmonic outflow, and mitral inflow were recorded. The following values were calculated: LA:AO diameter, ratio of peak E: peak A wave velocity (E:A ratio) for mitral inflow, and stroke volume (SV), cardiac output (CO) and cardiac index (CI) for both pulmonary and aortic outflow tracts. Maximal aortic velocities (AOmax) and velocity-time integral values (AO VTI) were significantly less than corresponding pulmonary outflow tract values (PAmax, PA VTI) but there was no difference in calculated values for SV, CO or CI. Calculated CO values were in the range expected based on the size of the species. Difficulties in aligning the aortic outflow tract for Doppler imaging may make pulmonary outflow Doppler values more consistent for use in estimating volume flow in ferrets.  相似文献   

20.
BackgroundEvaluation of left ventricular (LV) diastole is clinically important in cats with heart disease. Diastolic dysfunction is a main characteristic of feline cardiomyopathy and is associated with clinical signs and poor outcome. Numerous echocardiographic indices characterizing LV diastole exist, of which Doppler variables of transmitral flow and mitral annular motion are used most often. However, rapid heart rate (HR), a common finding in cats examined in the veterinary hospital environment, may cause summation of flow waves limiting interpretation of diastolic function.ObjectiveTo evaluate the effects of vagal maneuvers (gentle eyeball pressure and nasal planum massage) on HR and Doppler variables of LV diastolic filling.AnimalsTwenty-four healthy client-owned cats with summated transmitral flow waves at baseline.MethodsProspective observational study. Transthoracic echocardiography was performed and Doppler transmitral and mitral annular tissue Doppler velocities recorded both before and during vagal maneuvers. Data were compared using a paired t-test.ResultsApplication of vagal maneuvers temporarily decreased HR in all cats (mean reduction ± SD; 42 ± 22 bpm). The duration of HR reduction (<5 s, 5–10 s, and >10–15 s) was evenly distributed among groups (8 cats in each). Summated Doppler transmitral flow and mitral annular tissue velocity waves were separated during vagal maneuvers in 71% and 72% of cats, respectively. No adverse effects were observed.ConclusionsVagal maneuvers may be utilized as a simple non-pharmacologic tool in the Doppler evaluation of LV diastolic function in healthy cats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏