首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
The purpose of this study was to evaluate simplified methods for estimation of Technetium Tc 99m (99mTc)-pentetate and orthoiodohippurate I 131 (131I-OIH) plasma clearance in dogs and cats with 1 and 2 blood samples. Plasma clearances were calculated after a bolus injection of 1.85-11.1 MBq of 99mTc-pentetate and 131I-OIH with a 2-compartment model based on a 12-point curve as a reference method in 21 dogs and 18 cats. Three 2-sample and 3 single-sample methods were investigated. The method yielding the smallest standard deviation of the difference between the reference method and the simplified method was selected as the optimal one. Linear regression analysis was performed between the reference method and the simplified method and coefficient of determination (R2) was calculated. For 99mTc-pentetate plasma clearance, the optimal 2-sample method was the one with a mono-compartment model with samples taken at specific times. For 131I-OIH plasma clearance, the estimation was improved slightly by raising the clearance calculated with a mono-compartment model to the power of an empirically determined parameter. The optimal single-sample method was the one with a linear quadratic regression between the volume of distribution of the tracer at a specific time and the clearance calculated with 12 samples. Two-sample methods performed significantly better than did single-sample methods. The conclusion is made that 99mTc-pentetate and 131I-OIH plasma clearances can be estimated in dogs and cats with 1 or 2 blood samples with a reasonable margin of error compared to plasma clearances calculated with a 2-compartment model and 12 blood samples.  相似文献   

2.
The objective of this study was to determine if plasma iohexol clearance, computed by a 1-compartment model defined by 3 plasma samples. was an accurate measure of glomerular filtration rate (GFR) in dogs. Twenty-two adult Beagle dogs of both genders were studied. Ten dogs had intact kidneys, and 12 dogs had surgically reduced renal mass. A bolus injection of iohexol was made, and blood was obtained for plasma iohexol assay after 120, 180, and 240 minutes. Plasma was analyzed for iohexol concentration by means of 3 assay methods: chemical, high-performance liquid chromatography (HPLC), and inductively coupled plasma emission spectroscopy (ICP). Urinary clearance of exogenous creatinine was used to measure GFR for three 30-minute periods occurring between 150 and 240 minutes after iohexol injection. Plasma clearance of iohexol and renal clearance of creatinine were compared by linear regression analysis and by limits of agreement techniques. Plasma iohexol clearance and urinary exogenous creatinine clearance were significantly correlated (chemical R2 = .90; HPLC R2 = .96; and ICP R2 = .96). The 1-compartment iohexol clearance:exogenous creatinine clearance ratios were 1.04 +/- 0.17, 1.05 +/- 0.14, and 1.10 +/- 0.15 for the chemical, HPLC, and ICP methods of assay, respectively, indicating that plasma iohexol clearance slightly overestimated GFR. Assuming a +/- 2 standard deviation interval for error, corrected plasma iohexol clearance measured GFR with +/-34% accuracy for the chemical, +/-26% accuracy for the HPLC, and +/-27% accuracy for the ICP method. These results indicate that plasma iohexol clearance should have utility for detection of renal dysfunction earlier in the course of progressive renal disease than is possible with measurement of plasma creatinine or urea concentrations.  相似文献   

3.
OBJECTIVE: To determine the effect of number of blood samples and sampling times on plasma clearance of technetium Tc 99m pentetate (Tc99mP) and orthoiodohippurate sodium I 131(OIH). ANIMALS: 20 dogs and 14 cats. PROCEDURE: Plasma clearances of OIH and Tc99mP were calculated by use of a 2-compartment model, on the basis of a 12-point curve as a reference method. Plasma clearance was calculated by use of all possible combinations of 4 to 11 samples. Time schedule yielding the smallest difference from the reference method was considered to be optimal. Regression analysis was performed between the 12-point model and models using a reduced number of samples. RESULTS: SD of the difference between the 12-point clearance and the models with reduced numbers of samples increased when the number of samples decreased. The SD of the difference between 12-point clearance and 4-point clearance was 4.17 ml/min for OIH and 0.94 ml/min for Tc99mP in dogs and 0.45 ml/min for OIH and 0.11 ml/min for Tc99mP in cats. Optimal schedules were distributed logarithmically and included an early sample at 5 or 10 minutes, a late sample at 2.5, 3, 4, or 5 hours for OIH, and a late sample at 4 or 5 hours for Tc99mP. CONCLUSIONS AND CLINICAL RELEVANCE: Plasma clearances of OIH and Tc99mP can be accurately calculated in dogs and cats by use of a single-injection 2-compartment pharmacologic model with a reduced number of blood samples, resulting in an acceptable margin of error.  相似文献   

4.
OBJECTIVE: To determine whether pharmacokinetic analysis of data derived from a single i.v. dose of iohexol could be used to predict creatinine clearance and evaluate simplified methods for predicting serum clearance of iohexol with data derived from 2 or 3 blood samples in clinically normal foals. ANIMALS: 10 healthy foals. PROCEDURE: Serum disposition of iohexol and exogenous creatinine clearance was determined simultaneously in each foal (5 males and 5 females). A 3-compartment model of iohexol serum disposition was selected via standard methods. Iohexol clearance calculated from the model was compared with creatinine clearance. Separate limited-sample models were created with various combinations of sample times from the terminal slope of the plasma versus time profile for iohexol. Correction factors were determined for the limited-sample models, and iohexol clearance calculated via each method was compared with exogenous creatinine clearance by use of method comparison techniques. RESULTS: Mean exogenous creatinine clearance was 2.17 mL/min/kg. The disposition of iohexol was best described by a 3-compartment open model. Mean clearance value for iohexol was 2.15 mL/min/kg and was not significantly different from mean creatinine clearance. A method for predicting serum iohexol clearance based on a 2-sample protocol (3- and 4-hour samples) was developed. CONCLUSIONS AND CLINICAL RELEVANCE: Iohexol clearance can be used to predict exogenous creatinine clearance and can be determined from 2 blood samples taken after i.v. injection of iohexol. Appropriate correction factors for adult horses and horses with abnormal glomerular filtration rate need to be determined.  相似文献   

5.
Iohexol plasma clearance as a measure of glomerular filtration was determined in 31 dogs and 19 cats after an intravenous (i.v.) bolus injection. All animals were healthy and privately owned. Serial blood samples were taken before and up to 4 h after tracer injection. Iohexol plasma concentration was determined using X-ray fluorescence. A plasma tracer elimination curve was generated and clearance was calculated by dividing the injected dose by the area under the curve estimated using a two-compartment pharmacological model. Clearance was normalized to body weight (BW), body surface area (BSA), and extracellular fluid volume (ECFV). Mean, SD, and coefficient of variation of plasma clearance, before and after normalization, were calculated. Linear regression analyses were performed between body size and normalized plasma clearances. No significant linear relation was found between BSA and clearance normalized to BSA in dogs, and between BSA, BW, ECFV and clearance normalized to BSA, BW, and ECFV in cats. The optimal method for normalization of iohexol plasma clearance in dogs was by using BSA. In cats, all three methods tested were considered satisfactory. Normalization to BSA appears to be superior to normalization to BW and ECFV in dogs, and can be recommended for clinical use.  相似文献   

6.
The purpose of the present study was to compare different pharmacokinetic models for estimation of glomerular filtration rate (GFR) in 50 dogs with pyometra. GFR was estimated by plasma clearance (CLplasma) of iohexol by four 1-compartment methods (CL1c), a 2-compartment method (CL2c), and the trapezoidal method (CLtr). Regression analysis was performed to establish correction formulas for prediction of CLtr from the CL1c values and to find optimal times of sampling. Standardization of clearance values to body weight (kg), body surface area (m2) and extracellular fluid volume (ECFV) was compared by ranking of values. CLtr and CL2c values were similar, whereas CL1c overestimated CLtr. CLtr could be predicted from 2 samples at 2 and 3 hours after injection, using the formula CLtr = 4.52 + 0.84CL1c - 0.00080(CL1c)2 (R2 = .97). Similar relationships were found when sampling at 2 and 4 hours or at 2, 3 and 4 hours after injection, whereas predictions from the 3- and 4-hour estimates were not optimal (R2 = .79). The 2-sample methods for calculating GFR/ECFV generally produced unreliable predictions of the complete curve GFR/ECFV values. For some dogs, the choice of standardization procedure substantially changed the apparent level of renal function relative to other dogs in the study. We conclude that by applying an appropriate correction formula, GFR may be estimated using 2 blood samples at 2 and 3, or 2 and 4 hours after injection of iohexol when renal function is normal or moderately reduced. The method of standardizing the analysis with respect to body size may influence interpretation of the results substantially.  相似文献   

7.
Objective-To compare the use of a single-sample method involving IV administration of iodixanol with a multisample method involving inulin for the estimation of glomerular filtration rate (GFR) in cats. Animals-24 cats, including 15 healthy cats and 9 cats with naturally occurring renal diseases. Procedures-Each cat was coadministered iodixanol (a nonionic contrast medium; dose providing 40 mg of I/kg) and inulin (50 mg/kg), IV, and blood samples were collected 60, 90, and 120 minutes later. Serum iodixanol and inulin concentrations were determined by means of high-performance liquid chromatography and colorimetry, respectively. Serum urea nitrogen and creatinine concentrations were also measured. Results-Analysis of the data from healthy cats and cats with naturally occurring renal diseases revealed an excellent correlation between GFR values estimated by the multisample and single-sample methods with iodixanol. Likewise, GFR values estimated from the single-sample method with iodixanol were closely correlated with those calculated from the multisample method with inulin. Conclusions and Clinical Relevance-For estimation of GFR in cats, use of a single-sample method with iodixanol, instead of a multisample procedure, may be an expedient tool in both clinical and research settings because of its benefits to patient well-being as a result of reduced stress associated with blood sample collection.  相似文献   

8.
OBJECTIVE: To determine whether plasma clearance of iohexol (PCio) can be used to estimate glomerular filtration rate (GFR) in cats. ANIMALS: 4 renal-intact and 6 partially nephrectomized adult cats. PROCEDURE: Plasma clearance of iohexol was determined after IV administration of iohexol; plasma concentrations of iodine were measured by use of a colorimetric assay. Results for PCio were compared with simultaneously obtained values for urinary clearance of creatinine (CCr). RESULTS: The colorimetric assay used to measure plasma iodine concentrations was extremely precise. Results of PCio for all cats, renal-intact cats, and partially nephrectomized cats were closely associated with results of CCr. Mean difference between CCr and PCio determined for all cats was 0.95 ml/min/kg, which was < 30% of mean CCr for renal-intact cats. Coefficients of variance for PCio (5%) and CCr (8%) in renal-intact cats were similar. CONCLUSIONS AND CLINICAL RELEVANCE: Plasma clearance of iohexol determined by use of a simple colorimetric assay provided an estimation of GFR in cats that was not significantly different from that provided by CCr. Moreover, PCio more reliably estimates renal function than BUN and plasma creatinine concentrations. Because determination of PCio is less labor intensive and invasive, compared with CCr, it may be easier to perform in a clinical setting.  相似文献   

9.
We examined the correlation between the glomerular filtration rate (GFR) estimated from an equation based on the serum iodixanol clearance technique and International Renal Interest Society (IRIS) stages of chronic kidney disease (CKD) in cats. The equation included the injection dose, sampling time, serum concentration and estimated volume of distribution (Vd) of the isotonic, nonionic, contrast medium iodixanol as a test tracer. The percent changes in the median basal GFR values calculated from the equation in CKD cats resembled those of IRIS stages 1–3. These data validate the association between the GFR derived from the simplified equation and IRIS stages based on the serum creatinine concentration in cats with CKD. They describe the GFR ranges determined using single-sample iodixanol clearance for healthy cats and cats with various IRIS stages of CKD.  相似文献   

10.
BACKGROUND: Chronic kidney failure is frequently seen in middle-aged and elderly cats. 51Chromium-ethylene diaminic tetraacetic acid (51Cr-EDTA) clearance and single blood sample (SBS) method are used in several species to estimate the glomerular filtration rate (GFR). HYPOTHESIS: The hypothesis of this study was that 51Cr-EDTA clearance could be determined using an SBS method in normal and hyperthyroid cats. ANIMALS: Forty-six cats were included in this study, with an average age of 9.5 years. Of these cats, 27 had hyperthyroidism; 19 were healthy. METHODS: After IV injection of 51Cr-EDTA (average dose: 4.25 MBq), 7 blood samples were obtained between 5 and 240 minutes. Reference clearance was calculated in mL/min and mL/min/kg body weight, using a 2-compartment model. Optimal time for clearance measurement with SBS was then determined by systematically comparing each individual plasma concentration to the reference multisample clearance. RESULTS: The average reference plasma clearance of 51Cr-EDTA for all cats was 14.9 mL/min (3.7 mL/min/kg). The clearance in hyperthyroid cats averaged 16.4 mL/min (4.3 mL/min/kg) and in normal cats averaged 10.3 mL/min (2.4 mL/min/kg). The optimal time for the SBS was 48 minutes after injection of tracer 51Cr-EDTA (R2= 0.9414), giving the following converting equation: clearance = (0.0066 x DV48 minutes) - 0.9277 (in mL/min). CONCLUSIONS AND CLINICAL IMPORTANCE: In this study, the single sample 51Cr-EDTA clearance method was used to estimate the global GFR in cats. The method identified differences in clearance between normal and hyperthyroid cats. The optimal time for an SBS was 48 minutes.  相似文献   

11.
OBJECTIVE: To compare glomerular filtration rate (GFR) measured via urinary clearance of inulin (UCI) with plasma clearance of technetium Tc 99m pentetate (99mTc-pentetate) and creatinine in dogs. ANIMALS: 6 healthy Beagles and 18 Beagles with reduced renal function. PROCEDURE: 13 blood samples were obtained between 5 and 600 minutes after i.v. bolus injections of (99m)Tc-pentetate and creatinine. Plasma clearance of (99m)Tc-pentetate was computed on the basis of 1, 2, or 13 samples, and plasma clearance of creatinine was computed on the basis of 2, 5, or 13 samples. During plasma clearance procedures, constant i.v. infusion of carboxyl carbon 14 inulin was begun and UCI was determined in urine collected from 90 to 120, 120 to 180, and 180 to 240 minutes. Clearance procedures were repeated in 12 dogs to evaluate reproducibility of results. RESULTS: Significant association between UCI and plasma clearance was determined via all methods. However, plasma clearances were moderately to markedly different from UCI, depending on test substance, GFR, and sample numbers used for plasma clearance computations. Comparisons were particularly discordant when some methods of limiting samples were used to define plasma clearance. CONCLUSIONS AND CLINICAL RELEVANCE: Values derived from plasma clearance methods for (99m)Tc-pentetate and creatinine were not interchangeable with UCI results, which raises questions about their reliability as clinical research tools for measurement of GFR. Plasma clearance methods that are relative indices of renal function should not be interpreted as accurate measures of GFR without validation.  相似文献   

12.
Plasma disappearance of creatinine as a renal function test in the dog   总被引:2,自引:0,他引:2  
The serum concentration of creatinine at 120 minutes (SC120) after intravenous injection of 88 mg kg-1 of creatinine, the plasma half-life (t1/2) and the plasma clearance of creatinine (PCC) were evaluated as renal function tests in 30 healthy adult dogs and six adult dogs with known or suspected renal disease. The mean SC120 in the normal dog was 0.31 +/- 0.08 mmol litre-1 and in the clinical cases 0.71 +/- 0.19 mmol litre-1. The correlation coefficients between SC120 and renal creatinine clearance (RCC) for the normal dogs and the clinical cases were -0.76 and -0.69, respectively. At 120 minutes after injection, 95 per cent of normal dogs would be predicted to have a serum creatinine concentration below 0.46 mmol litre-1. The mean plasma t1/2 of creatinine for the normal dogs was 107.7 +/- 17.96 minutes, while the clinical cases had a wide range of values (148.8 to 620.1 minutes). Plasma t1/2 of creatinine was correlated with RCC for both the normal dogs and the clinical cases (r = -0.55, r = -0.91, respectively). The mean PCC for the normal dogs was 7.42 +/- 2.22 ml min-1 kg-1 (range 4.95 to 13.28 ml min-1 kg-1). There was a good correlation between RCC and PCC (r = 0.7). The PCC for the clinical cases ranged from 0.76 to 3.37 ml min-1 kg-1. The correlation between RCC and PCC was significant (r = 0.91). Thus SC120, t1/2 and PCC may be useful methods of assessing renal function in dogs with renal impairment insufficient to cause azotaemia.  相似文献   

13.
The objectives of this study were to compare assay methods for plasma creatinine (Pl-creat) in cats and to describe the disposition of creatinine and iohexol in 12 healthy and moderately azotaemic cats. Exogenous creatinine and iohexol were injected simultaneously by intravenous bolus, and repeated blood samples were taken to determine the pharmacokinetic parameters of each marker. Pl-creat was assayed by high-performance liquid chromatography (HPLC), Jaffé and enzymatic methods. The enzymatic method was shown to be more reliable than the Jaffé method. Two stereoisomers, exo- and endo-iohexol were identified. The plasma clearance of creatinine (2.3+/-0.66 ml/min/kg) was significantly higher (P<0.001) than that of exo-iohexol (1.7+/-0.40 ml/min/kg). The volume of distribution (447+/-97 ml/kg) and elimination half-life (181+/-77 min) of creatinine were also higher (P<0.001) than those of exo- and endo-iohexol. The estimated daily endogenous production of creatinine was 65+/-23 mg/kg. None of the pharmacokinetic parameters was changed by the azotaemic status of the animals.  相似文献   

14.
Background: Chronic kidney failure is frequently seen in middle-aged and elderly cats. 51Chromium-ethylene diaminic tetraacetic acid (51Cr-EDTA) clearance and single blood sample (SBS) method are used in several species to estimate the glomerular filtration rate (GFR).
Hypothesis: The hypothesis of this study was that 51Cr-EDTA clearance could be determined using an SBS method in normal and hyperthyroid cats.
Animals: Forty-six cats were included in this study, with an average age of 9.5 years. Of these cats, 27 had hyperthyroidism; 19 were healthy.
Methods: After IV injection of 51Cr-EDTA (average dose: 4.25 MBq), 7 blood samples were obtained between 5 and 240 minutes. Reference clearance was calculated in mL/min and mL/min/kg body weight, using a 2-compartment model. Optimal time for clearance measurement with SBS was then determined by systematically comparing each individual plasma concentration to the reference multisample clearance.
Results: The average reference plasma clearance of 51Cr-EDTA for all cats was 14.9 mL/min (3.7 mL/min/kg). The clearance in hyperthyroid cats averaged 16.4 mL/min (4.3 mL/min/kg) and in normal cats averaged 10.3 mL/min (2.4 mL/min/kg).
The optimal time for the SBS was 48 minutes after injection of tracer 51Cr-EDTA ( R 2= 0.9414), giving the following converting equation: clearance = (0.0066 × DV48 minutes) – 0.9277 (in mL/min).
Conclusions and Clinical Importance: In this study, the single sample 51Cr-EDTA clearance method was used to estimate the global GFR in cats. The method identified differences in clearance between normal and hyperthyroid cats. The optimal time for an SBS was 48 minutes.  相似文献   

15.
The digestion of bentiromide and the absorption of D-xylose was measured in 17 clinically healthy cats. The plasma xylose concentrations of the healthy cats were compared with values from 9 cats with diffuse infiltrative intestinal disease. The cats were administered 16.7 mg of bentiromide/kg and 0.5 g of xylose/kg via a stomach tube. Plasma samples were obtained before administration and 30, 60, 90, and 120 minutes after administration. The maximum mean plasma p-aminobenzoic acid concentration occurred at 60 minutes, with a value of 386 +/- 134 micrograms/dl (mean +/- SD). The maximum mean plasma xylose concentration also occurred at 60 minutes, with a value of 26.0 +/- 9.2 mg/dl. Plasma concentrations of p-aminobenzoic acid and xylose were lower in healthy cats than those reported for healthy dogs. There was no significant difference between xylose concentrations in healthy cats and cats with infiltrative intestinal disease.  相似文献   

16.
The purpose of this project was to establish a procedure and reference values for glomerular filtration rate (GFR) using contrast-enhanced computed tomography (CT) in eight healthy dogs. A single section of the kidney was scanned sequentially after bolus injection (3 ml/s) of iohexol (300 mg/kg). Time-attenuation curves were constructed and the GFR per volume of kidney was calculated using Patlak graphical analysis software. The GFR was then converted from contrast clearance per unit volume (ml/min/ml) to contrast clearance per body weight (ml/min/kg). Individual kidney and global GFR were calculated using both CT and nuclear scintigraphy. Global GFR for each dog was also determined by plasma iohexol clearance. Contrast-enhanced CT underestimated the global GFR compared with the other two methods. The average global GFR was 2.57 +/- 0.33 ml/ min/kg using functional CT and 4.06 +/- 0.37 ml/min/kg using plasma iohexol clearance. There was significant (P < 0.05) interobserver variability of CT GFR of the right kidney and total GFR. There was decreased interobserver variability for the left kidney. There was no difference in the intraobserver variability for CT-determined individual kidney and global GFR. There was no difference between the motion corrected and nonmotion corrected values for individual and global CT GFR. Nuclear scintigraphy produced a slightly higher coefficient of variation than contrast-enhanced CT, 2.9% and 1.0%, respectively. It is hypothesized that altered renal blood flow, hematocrit of the small vessels, and nephrotoxicity play a role in the underestimation of GFR by contrast-enhanced CT.  相似文献   

17.
Quantitative fat absorption was studied in normal dogs and in dogs with hypothyroidism and diabetes mellitus. The serum triglyceride concentrations of diabetic and hypothyroid dogs were significantly higher at each sampling time than those of normal dogs. The fat absorption curve of hypothyroid dogs peaked at 180 minutes and though significantly raised was parallel to that of normal dogs whereas the fat absorption curve of diabetic dogs continued to rise up to 240 minutes. These results provide evidence for impaired plasma clearance of triglyceride in canine diabetes mellitus and hypothyroidism.  相似文献   

18.
A double-isotope single-injection method without urine collection for the estimation of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in dogs and cats was evaluated. The GFR was determined, using 14C-inulin and ERPF was determined, using [3H]tetraethylammonium bromide. Using a modified single exponential, 1-compartment mathematical model, the renal clearance of these solutes was estimated with a plasma radioactivity disappearance curve constructed from samples collected over a 150-minute time period. In 25 dogs, GFR, ERPF, and filtration fraction were 3.55 +/- 0.14 ml/kg/min, 10.51 +/- 0.72 ml/kg/min, and 0.34 +/- 0.02, respectively. In 25 cats, GFR, ERPF, and filtration fraction were 3.24 +/- 0.14 ml/kg/min, 8.14 +/- 0.53 ml/kg/min, and 0.39 +/- 0.02, respectively. This time-efficient and reliable method, using beta-emitting isotopes, yielded renal functional values well within the normal ranges reported by a variety of other isotopic and nonisotopic procedures. The advantages of the present procedure over previous double-isotope single-injection methods include the use of less costly, lower energy-using, and less penetrating beta emittors, as well as a shortened blood sampling schedule.  相似文献   

19.
Alfentanil (50 μg/kg) was administered intravenously, over 1 minute, to 6 healthy cats. Blood samples were collected from a preplaced arterial catheter at 0.625, 1.25, 2.5, 5, 10, 15, 20, 30, 45, 60, 90, 120, 180, 240, 360, and 480 minutes after the end of the alfentanil injection. A radio-immunoassay technique was used to measure alfentanil concentrations in plasma obtained from these samples. Arterial blood pressure was measured at 0.625, 1.25, 2.5, 5, 10, 15, 20, and 30 minutes and pH and blood gas measurements were carried out at 5, 10 and 30 minutes after the alfentanil. Analgesia, tested by placing a clamp on the base of the tail for 5 seconds, was assessed at each blood sampling time until analgesia was absent. The cats were observed for behavioural changes at each sample time. Alfentanil caused a transient increase in blood pressure and respiratory and metabolic acidosis. Following alfentanil all cats became excited and showed pupillary dilation. Analgesia was present for 21.7 ± 14 minutes. The plasma concentration-time data for 5 cats were best described by a 3 compartment open model with the curve fitting the equation: Cto= 162.6e-0.2062t+ 60.le-0.041t+ 13.2e-0.0062t The harmonic means for the half lives of the rapid distribution, the slow distribution and the elimination phases were 4.12, 18.8, 119.2 minutes respectively.  相似文献   

20.
A suitable method in the routine veterinary practice for the quantitative determination of the glomerular filtration rate (GFR) in dogs and cats has not been available until to date. Therefore, we modified the known plasma clearance model (=P-CL). The resulting P-CLterminal was assessed concerning its diagnostic value. P-CL of exogenous creatinine (P-CLcrea) and of inulin were determined in dogs (n=12, Beagle, 6 months of age) and cats (n=11, Domestic Short Hair, 14 months of age). The marker substances were administered as a bolus injection. In fasted dogs, P-CLcrea was 84.3 +/- 14.85 ml/min/m2 after a creatinine dose of 2.4 g/m2. An electrolyte infusion during the clearance determination did not alter the resulting values (p>0.05). In fasted cats, P-CLcrea was 54.7 +/- 5.8 ml/min/m2 (creatinine dose 2.0 g/m2). The inulin clearance, determined at the same time, was 104.5 +/- 19.81 ml/min/m2. Feeding the cats just before and during the test increased P-CL of both markers significantly (p<0.05). In order to adapt the clearance method for diagnostic assessment of GFR in the small animal practice, we aimed at minimizing the number of required blood samples (3 instead of 7 or more) and introduced the modified exogenous creatinine clearance (P-CLterminal). These values determined were 108.4 +/- 20.81 ml/min/m2 in fasted dogs and 66.3 +/- 11.81 ml/min/m2 in fasted cats. An electrolyte infusion (dogs) and feeding (cats) had the same effect on P-CLterminal values as described above for P-CL. In conclusion,the modified exogenous creatinine clearance is a suitable renal function test for the early diagnosis of renal disease in dogs and cats presented in small animal practices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号