首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
99mTc-mebrofenin is used in humans and small animals to assess hepatic function. This study was undertaken to measure hepatic clearance of 99mTc-mebrofenin in healthy horses and to determine whether feed deprivation and increased serum total bilirubin (TBIL) concentration alter 99mTc-mebrofenin clearance. Plasma clearance of 99mTc-mebrofenin was determirned in 7 healthy horses at 0, 48, and 96 hours of feed withholding. Serum TBIL and nonesterified fatty acid (NEFA) concentrations were measured every 24 hours. 99mTc-mebrofenin (4.16 +/- 0.62 mCi, mean +/- SD) was injected into a jugular vein, and blood samples were retrieved from the contralateral jugular vein. A plasma time-activity curve of 99mTc-mebrofenin was generated, from which the area under the curve (AUC) and the T1/2 of the fast-phase (T1/2) and slow-phase (T1/2f) were calculated. Mean +/- SD AUC was 17,700 +/- 4,257, 18,616 +/- 8,078, and 16,168 +/- 6,031 counts per minute (cpm) at 0, 48, and 96 hours, respectively; mean +/- SD T1/2f was 2.80 +/- 0.38 minutes, 3.52 +/- 1.46 minutes, and 3.82 +/- 1.29 minutes at 0, 48, and 96 hours, respectively; median T1/2s was 63.9, 49.2, and 45.8 minutes at 0, 48, and 96 hours, respectively. No difference was detected between the values of AUC, T1/2f, and T1/2s at 0, 48, and 96 hours. There was a significant increase in TBIL with fasting, with a mean +/- SD of 6.3 +/- 1.3 mg/dL at 26 hours. NEFAs increased, reaching a plateau at 48 hours (650 +/- 152 micromol/L). Plasma TBIL concentrations did not correlate with AUC or T1/2s but correlated weakly with T1/2f (r = 0.50). Plasma NEFA concentrations did not correlate with AUC, T1/2s, or T1/2f values. This study suggests that 99mTc-mebrofenin plasma clearance is not affected by feed withholding and that hyperbilirubinemia associated with feed withholding does not affect the hepatic extraction efficiency of this radiopharmaceutical.  相似文献   

2.
Per rectal portal scintigraphy using 99mTechnetium pertechnetate (99mTcO4-) was used to diagnose portosystemic shunts (PSS) before surgical confirmation in seven dogs and two cats. Shunt fractions, representing the percent of portal blood that bypasses the liver, were determined by computer analysis of the scintigraphic images. Animals with portosystemic shunts had a mean preoperative shunt fraction of 84.02% (n = 9). The mean postoperative shunt fraction in four animals was 58.22%. The mean shunt fraction in ten control dogs was 5.00%. Per rectal portal scintigraphy is an innovative, easily performed, inexpensive method to diagnose congenital portosystemic shunts in dogs and cats.  相似文献   

3.
The purpose of this study was to (1) establish a technique for ultrasound-guided trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-), (2) evaluate portal vein morphology, (3) compare the radiation exposures for TSPS vs. per-rectal portal scintigraphy (PRPS), and (4) compare the quality of numerical data from the TSPS vs. PRPS. Eight juvenile dogs underwent PRPS and TSPS (minimum of 48h between studies) after initial screening tests. PRPS was done according to established protocol using 425 +/- 36MBq (mean +/- SD) of 99mTcO4(-). TSPS was done with the dogs in right lateral recumbency over the gamma camera. 99mTcO4(-) (57 +/- 13.9 MBq) was injected into the spleen 1-2s following initiation of the dynamic acquisition. The frame rate was 4 frames/s for 5 min. There was significantly lower radioactivity of 99mTcO4(-) given and significantly higher total counts recorded in the liver and heart during the TSPS compared with PRPS. The total counts for the TSPS and PRPS were 7120 +/- 4386 and 830 +/- 523, respectively. Percent absorption from the spleen was 52.5 +/- 19.1% compared with 9.2 +/- 5.7% for the colon. Calculated transit time for the TSPS studies was 7 +/- 2.3s. In TSPS studies, the splenic and portal veins were clearly identified. Radiation exposure levels of the dogs were significantly lower following TSPS than after PRPS. TSPS appears superior to PRPS as a method to image the portal venous system representing a valid alternative diagnostic test for animals with suspected portosystemic shunts.  相似文献   

4.
In this study, plasma time-activity curves of 99mTc-mebrofenin were used to quantify hepatic function in dogs before and after induction of hepatic damage using a hepatotoxic agent. Nine dogs were determined to be healthy on the basis of physical examination, laboratory data and hepatic imaging. Plasma samples were collected 1, 3, 5, 7, 9, 15, 20, 30, 40, 50, and 60 minutes following a peripheral venous injection of 111-222 MBq (3-6 mCi) of 99mTc-mebrofenin. The area under the plasma time-activity curve (AUC) was calculated using two different methods and compared to direct measurement of the hepatic extraction efficiency. First pass hepatic extraction efficiency of 99mTc-mebrofenin was calculated from differential equation analysis of a two-compartment model following mesenteric venous injection of the radiopharmaceutical. In 7 of the original 9 dogs and 2 additional healthy dogs, plasma clearance and hepatic extraction efficiency determination were repeated following induction of hepatic injury by thiacetarsamide (3 mg/kg IV twice daily for 1 day). In one additional dog, hepatic injury was induced using carbon tetrachloride (0.3 ml/kg IP). Plasma time-activity curves of 99mTc-mebrofenin had kinetics of a two compartment model. Area under the curve was highly correlated with hepatic extraction efficiency. The AUC integrated from 1-60 minutes (AUC60) had the best correlation with hepatic extraction efficiency (r2 = 0.978, p < 0.001). A formula for calculation of hepatic extraction efficiency was derived using linear regression analysis: hepatic extraction efficiency = 105.583 - 3.099 x 10(5) x AUC60. Plasma clearance of a peripheral venous injection of 99mTc-mebrofenin is a simple, non-invasive, convenient method to quantify hepatic function which can be performed without a gamma camera.  相似文献   

5.
Quantitative hepatobiliary scintigraphy using 99mTc-2,6 diisopropylphenylcarbamoylmethyl iminodiacetic acid (DISIDA) was performed in normal dogs. 99mTc-DISIDA is excreted by the hepatocyte into the biliary tract. Hepatic blood flow from arterial and portal venous sources was measured as the hepatic perfusion index. The hepatic clearance of the radiopharmaceutical was used to assess hepatocyte function and parenchymal biliary transport. Biliary ejection was evaluated using synthetic cholecystokinin infusion. The procedure should be useful in evaluating dogs with hepatic and biliary disease.  相似文献   

6.
The purpose of this study was to evaluate nonuniform patterns of vascular distribution of pertechnetate in the dog during per-rectal portal scintigraphy. Ninety-two studies were reviewed retrospectively to document the patterns of radionuclide distribution. Forty-five studies were classified as normal and 47 were classified as diagnostic for a macrovascular portosystemic shunt. In these dogs, shunt fractions were calculated and compared using a t-test. In dogs with sufficient liver radioactivity for evaluation, the study was classified as having uniform, dorsal, central, or ventral radiopharmaceutical distributions. There were 51 animals (45 normal and six dogs with low-magnitude portosystemic shunts) with sufficient liver activity to assess the radionuclide distribution within the liver. A one-way ANOVA was used to compare shunt fractions between each of the distribution patterns. Two dogs were anesthetized and selective portovenograms were performed. Portovenograms were compared with the scintigraphic images to correlate the vascular distribution of the right, central, and left divisional branches of the portal vein. The shunt fraction in the 45 normal dogs was significantly lower than in the dogs with portosystemic shunts (5.7% +/- 4.8% vs. 78.6% +/- 20.0% (mean +/- SD), P < 0.001). Of the 51 dogs with sufficient liver activity to classify the pattern of distribution, there were 15/51 (31.4%) with uniform radionuclide distribution, 10/51 (19.6%) with focal dorsal distribution, 15/51 (29.4%) with focal ventral distribution, and 10/51 (19.6%) with focal central distribution. There was no significant difference in the shunt fractions between the groups. There were six dogs diagnosed with low-magnitude portosystemic shunt with sufficient liver radioactivity to categorize the vascular distribution of the radionuclide within the liver. Of these six dogs, two had focal dorsal distribution, one had focal central, one had focal ventral and two had uniform distribution. Focal dorsal distribution could result from streamlining of the radionuclide into the right divisional branch of the portal vein. Focal ventral distribution could result from streamlining the radionuclide into the left divisional branch of the portal vein. Focal central distribution could result from streamlining the radionuclide into the central divisional branch of the portal vein.  相似文献   

7.
Ultrasound-guided percutaneous trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-) has been used to image the portal venous system in normal dogs. Compared with per-rectal portal scintigraphy, it provides higher count density, consistent nuclear venograms of the splenic and portal vein, and significantly decreased radiation exposures. This paper describes the use of TSPS for the diagnosis of portosystemic shunts in 28 dogs. TSPS was performed injecting 70 +/- 28 MBq of 99mTcO4(-) (mean +/- SD) into the splenic parenchyma with ultrasound guidance. A dynamic acquisition at a frame rate of four frames/s for 5 min was initiated after placement of the needle and approximately 2s prior to injection. All dogs had diagnoses confirmed via exploratory laparotomy or ultrasonographic identification of the shunting vessel(s). Three studies (10.7%) were nondiagnostic because of intraperitoneal rather than intrasplenic injection of the radionuclide. Three pathways were recognized on the scintigraphic images: (1) portoazygos shunts--the 99mTcO4(-) bolus traveled dorsally, running parallel to the spine and entering the heart craniodorsally; (2) single portocaval or splenocaval shunts--the 99mTcO4(-) bolus ran from the area of the portal vein/splenic vein junction in a linear fashion toward the caudal vena cava entering the heart caudally; (3) internal thoracic shunt-the 99mTcO4 bolus traveled ventrally along the thorax and abdomen entering the cranial aspect of the heart. Single and multiple shunts were easily distinguished. There were no distinguishing features between single intra and extrahepatic portocaval shunts.  相似文献   

8.
This study investigated the use of quantitative hepatobiliary scintigraphy to assess liver function in 14 white Carneaux pigeons (Columba livia). Liver scintigraphy using 99mTc-mebrofenin was performed and liver function was quantified using deconvolutional analysis and the area under the normalized heart time-activity curve as previously described in the dog and horse. Liver biopsies were performed in all birds before and after toxin-induced liver damage with ethylene glycol. Before the induction of liver disease, all biopsy specimens showed varying degrees of granulomatous inflammation. After ethylene glycol administration, hepatic lesions were scored and compared with scintigraphic findings. Scintigraphic results showed a significant decrease (P = 0.04) in hepatic function using the area under the normalized time-activity curve. There was good correlation between the overall histologic score posttoxin exposure and scintigraphic measures of liver function (P < 0.03). Based upon these preliminary results, the area under the heart time-activity curve can determine hepatic extraction as a measure of hepatic parenchymal cell function. The results also showed that worsening hepatic cellular function correlated with increased histologic damage to the liver. The use of hepatobiliary scintigraphy using 99mTc-mebrofenin to determine liver function in pigeons has not been previously reported. Additional studies are warranted to evaluate the application of this technique in clinical patients and to establish the sensitivity of this technique.  相似文献   

9.
Gregory B.  Daniel  DVM  MS  Ronald  Bright DVM  MS  Eric  Monnet  DVM  Paul  Ollis  RT 《Veterinary radiology & ultrasound》1990,31(4):175-181
Per-rectal portal scintigraphy using tech-netium-99m pertechnetate (99mTcO4-) was performed in 8 normal dogs before and after surgical creation of a portacaval shunt. Shunt fractions were calculated by computer assisted analysis of dynamic images (IMG) and compared to shunt fractions determined by mesenteric venous injection of radioactive microspheres (MIC). The mean pre-operative shunt fraction was 1.59% using IMG and 3.00% using MCI. The mean postoperative shunt fraction was 64.56% using IMG and 69.56% using MIC. There was excellent correlation between both methods (r2 0.94). Per-rectal portal scintigraphy is an easily performed, inexpensive method to diagnose and quantify portosystemic shunts in dogs.  相似文献   

10.
Diagnosing right-to-left congenital cardiac shunts can be difficult. Cardiac catheterization and angiocardiography represent the traditional gold standard for diagnosis, but they are invasive. Nuclear scintigraphy using 99mTc-macroaggregated albumin (MAA) has been employed in humans as an alternate method of diagnosis. This study reviews eight dogs presented for evaluation of a suspect right-to-left cardiac shunt that were examined using 99mTc-MAA. In all, 2-4 mCi (74-148 MBq) of reduced particle 99mTc-MAA were injected IV in a cephalic vein and static images of the whole body, including right and left lateral, dorsal, and ventral views, were acquired for 60 s and stored into a 256 x 256 x 16 matrix. Shunt fractions were calculated. One dog with radiopharmaceutical distribution limited to the lungs did not have a shunt. Seven dogs had distribution of the radiopharmaceutical outside the pulmonary capillary bed, indicating bypassing of the pulmonary capillary circulation due to a right-to-left shunt. Four dogs had 99mTc-MAA within the brain. Three dogs that did not have brain uptake, but instead had a sharp cutoff of radioactivity at the level of the front limbs and neck, were diagnosed with reverse patent ductus arteriosus (PDA). The asymmetric distribution of the radiopharmaceutical is due to the location of the shunt, distal to the brachiocephalic trunk and left subclavian artery. Shunt fractions of dogs with extrapulmonary radioactivity ranged from 40% to 59%. Nuclear scintigraphy with 99mTc-MAA is a quick alternative method of diagnosing right-to-left cardiac shunts that permits quantification of shunt fraction. Distinguishing between reverse PDA and other right-to-left shunts may be possible based on the radiopharmaceutical distribution.  相似文献   

11.
Gregory B.  Daniel  DVM  MS  Robert  DeNovo  DVM  MS  Anne  Bahr  DVM  MS  Gary T.  Smith  MD 《Veterinary radiology & ultrasound》2001,42(2):162-168
In this study, heart time-activity curve, created following intravenous injection of 99mTc-mebrofenin were used to quantify hepatic function in normal dogs and dogs with induced hepatic parenchymal cell damage. The results were compared to a direct measurement of hepatic extraction following mesenteric venous injection of 99mTc-mebrofenin. The heart time-activity curves were normalized and the area under the curve from 0-30 minutes and 0-60 minutes were determined. In addition, the half-time clearance rate of the heart time-activity curve was analyzed using a two-compartment model. Linear regression analysis was used to describe the relationship between the area under the normalized heart time-activity curve and hepatic extraction. There was good correlation between the area under the normalized heart time-activity curve and hepatic extraction. The best correlation was obtained from the 0-30 minute data (r2 = 0.92). A formula for calculating hepatic extraction was derived using linear regression analysis: Hepatic extraction = 1.092 - (0.0000308 x AUC0-30 minutes). There was good correlation between the half-time clearance rates from the heart time-activity curve and hepatic extraction. The best correlation was between the fast phase half-time clearance and hepatic extraction (r2 = 0.88). The area under a normalized heart time-activity curve can be used as a simple alternative to deconvolutional analysis for the determination of hepatic extraction as a measure of hepatic parenchymal cell function in the dog.  相似文献   

12.
Thyroid scintigraphy using sodium 99mTechnetium pertechnetate (99TcO4-) was performed in normal and radiothyroidectomized cockatiels ( Nymphicus hollandicus ). 131I scintigraphy was performed in the course of ablating the thyroid glands. The thyroid glands in normal birds were clearly visualized, but were not individually resolvable. Thyroid glands were not visualized in thyroid-ablated birds. With 99mTcO4 scans, thyroid (or other region of interest)/body count density ratios were used for comparisons of normal and thyroid-ablated birds. Normal 99mTcO4- thyroid/body ratios (mean +/− SD) for the dorsal and lateral views were 1.83 +/− 0.31 and 1.70 +/− 0.34 respectively. Pertechnetate thyroid/body count density ratios decreased (to 0.93 -/−0.14 and 0.88 +/− 0.12 for dorsal and lateral views respectively) after thyroid ablation, while crop/body ratios increased. 99mTcO4- thyroid scintigraphy, therefore, was capable of detecting hypofunctional thyroid abnormalities in 131I radiothyroidectomized cockatiels.  相似文献   

13.
OBJECTIVE: To compare hepatic, pancreatic, and gastric perfusion on dynamic computed tomography (CT) scans of clinically normal dogs with those of dogs with portal vascular anomalies. SAMPLE POPULATION: Dynamic computed tomography (CT) scans of 10 clinically normal dogs and 21 dogs with portal vascular anomalies. PROCEDURES: Retrospective analysis of dynamic CT scans. Hepatic arterial perfusion, hepatic portal perfusion, total hepatic perfusion, hepatic perfusion index, gastric perfusion, and pancreatic perfusion were calculated from time attenuation curves. RESULTS: Mean +/- hepatic arterial perfusion was significantly higher in affected dogs (0.57 +/- 0.27 mL/min x mL(-1)) than in clinically normal dogs (0.23 +/- 0.11 mL/min x mL(-1)), and hepatic portal perfusion was significantly lower in affected dogs (0.52 +/- 0.47 mL/min x mL(-1)) than in clinically normal dogs (1.08 +/- 0.45 mL/min x mL(-1)). This was reflected in the hepatic perfusion index, which was significantly higher in affected dogs (0.59 +/- 0.34), compared with clinically normal dogs (0.19 +/- 0.07). Gastric perfusion was significantly higher in dogs with portal vascular anomalies (0.72 +/- 0.44 mL/min x mL(-1)) than in clinically normal dogs (0.41 +/- 0.21 mL/min x mL(-1)), but total hepatic perfusion and pancreatic perfusion were not significantly different. Among subgroups, dogs with congenital intrahepatic portosystemic shunts and dogs with arterioportal fistulae had higher hepatic arterial perfusion than did clinically normal dogs. Dogs with congenital intrahepatic portosystemic shunts also had an increase in gastric perfusion and hepatic perfusion index. CONCLUSIONS AND CLINICAL RELEVANCE: Hepatic perfusion variables measured on CT scans revealed differences in hemodynamics between clinically normal dogs and those with portal vascular anomalies.  相似文献   

14.
Quantitative hepatic scintigraphy is a noninvasive test for measurement of relative arterial and portal blood flow to the liver. This technique has been used to evaluate human patients with known or suspected liver tumors or diffuse hepatocellular disease. A computer program to assess the hepatic perfusion index (HPI) in the normal dog is described. Factors affecting study quality and accuracy include injection technique, cardiac function, patient position, respiration, gross patient motion, and user intervention during data processing. HPI for a group of 12 normal dogs was 0.9±0.4 (X±SD). Quantitative scintigraphy could be used to evaluate dogs with primary or secondary liver tumors, portacaval shunts, or chronic liver disease  相似文献   

15.
OBJECTIVE:To evaluate the use of a portocaval venograft and ameroid constrictor in the surgical management of intrahepatic portosystemic shunts (PSS). STUDY DESIGN: Prospective, clinical study. Animal Population: Ten client-owned dogs with intrahepatic PSS. METHODS: Portal pressure was measured after temporary suture occlusion of the intrahepatic PSS. In dogs with an increase in portal pressure greater than 8 mm Hg, a single extrahepatic portocaval shunt was created using a jugular vein. An ameroid ring was placed around the venograft and the intrahepatic PSS was attenuated. Transcolonic pertechnetate scintigraphy was performed before surgery, 5 days after surgery, and 8 to 10 weeks after surgery. Dogs with continued portosystemic shunting were evaluated further by laparotomy or portography. Clinical outcome and complications were recorded. RESULTS: Mean (+/- SD) portal pressure increased from 6 +/- 3 to 19 +/- 6 mm Hg with PSS occlusion; in all 10 dogs, the increase in portal pressure was greater than 8 mm Hg. There were no intraoperative complications, and, after creation of the portocaval shunt, the intrahepatic PSS could be completely ligated in 8 of 10 dogs. The final portal pressure was 9 +/- 4 mm Hg. Postoperative complications included coagulopathy and death (1 dog), ascites (3 dogs), and incisional discharge (3 dogs). Five of 8 dogs had continued portosystemic shunting at 8 to 10 weeks after surgery. Multiple extrahepatic PSS were demonstrated in 4 of these dogs. Clinical outcome was excellent in all 9 surviving dogs. CONCLUSIONS AND CLINICAL SIGNIFICANCE: The surgical technique resulted in a high incidence of multiple extrahepatic PSS. Short-term clinical results were promising, but long-term outcome must be evaluated further.  相似文献   

16.
The biological and imaging characteristics of technetium-99m imidodiphosphate (Tc99m-IDP) were measured in 4 horses once and in 1 horse twice. All computational results are expressed with 95.5% (mean +/- 2 SD) confidence limits. The clearance half-time of the radiopharmaceutical from the blood was 29.6 +/- 2.3 min. The percentage of the administered dose circulating in the whole-blood volume at 4 h was 3.9 +/- 0.8%. The Tc99m-IDP radioactivity confined at the plasma fraction of the whole blood at 4 h was 85.3 +/- 1.6%. At 8 h, approximately 45 +/- 16% of the dose administered had been excreted via the urine. The mean effective half-time of the urine activity concentration was 1.1 +/- 0.3 h. The ratios of bone-to-soft tissue activities increased with time postinjection. Urinary radioactivity concentration measurements and radiation dose rate measurements immediately behind the elbows were analysed and it was determined that 24 h is an appropriate radioisolation time for mature horses administered 3.7 GBq (100 mCi) Tc99m-IDP.  相似文献   

17.
99mTechnetium-pertechnetate, when administered in high concentration into the colon, is rapidly absorbed across the colonic mucosa and results in a nuclear angiogram of the portal circulation. In normal dogs, a series of dynamic lateral scintigraphic images of the abdomen resulted in sequential visualization of the portal vein, liver, and several seconds later, the heart and lungs. In contrast, studies performed in 9 dogs with surgically confirmed portosystemic shunts demonstrated a different pattern of distribution, with heart and lung activity occurring before liver activity. In several cases, the aberrant shunt vessels could be identified. Studies were easy to perform, were well tolerated, and required no computer processing for interpretation.  相似文献   

18.
Susan M.  Newell  DVM  MS  John P.  Graham  MVB  MSc  Gregory D.  Roberts  DVM  MS  Pamela E.  Ginn  DVM  Ellis C.  Greiner  PhD  Amy  Cardwell  CVT  Danielle  Mauragis  CVT  Christine  Knutsen  DVM  Jay M.  Harrison  MS  Frank G.  Martin  PhD 《Veterinary radiology & ultrasound》2001,42(1):70-76
Quantitative hepatobiliary scintigraphy using 99mTc-mebrofenin was performed on eight normal cats and on the same cats after induction of experimental cholangiohepatitis by infection with the liver fluke Platynosomum concinnum. Hepatobiliary scintigraphy was performed 3 times at 10 weeks, 4 months and 6 months after infection. In addition, routine biochemical tests, hepatic ultrasound and ultrasound guided hepatic biopsy samples were obtained at the same time points, and the results compared with hepatobiliary scintigraphy. The normal hepatic extraction fraction was determined to be 85%, and the normal hepatic excretion half time (T 1/2) was 14 minutes. There was no significant change in scintigraphic parameters compared to pre-infection values at any time following infection with the liver fluke. No correlation between scintigraphic parameters and histologic scores was found; however, significant correlation was identified between parasite burden and histologic scores 6 months following infection. Despite the presence of severe multifocal histologic abnormalities, minimal clinical, biochemical and scintigraphic derangements were identified using this model of cholangiohepatitis. Based on this study, hepatobiliary scintigraphy appears to be an insensitive test for structural hepatobiliary abnormalities. The role of hepatobiliary scintigraphy in functional hepatobiliary abnormalities of the feline liver has not been determined.  相似文献   

19.
Liver contrast X-ray computed tomography (CT) has been used for evaluation of hepatic vessels for liver transplantation, liver lobectomy, interventional radiology and diagnosis of hepatocellular carcinoma in humans. However, there remains scant available anatomical information on normal hepatic vessels in the veterinary field. In this study, visualization of hepatic vessels was evaluated in 32 normal beagle dogs by X-ray contrast CT using triple phase images. The following hepatic vessels were clearly visualized: arterial, portal and hepatic veins. With regards to the running patterns of the portal vein and hepatic vein, there were no significant differences between the dogs. However, the hepatic artery exhibited some differences in each dog. In particular, the hepatic artery of the quadrate lobe and the right lateral lobe had many running patterns. The results of the present study could be useful for veterinary diagnosis, surgery and interventional radiology.  相似文献   

20.
Nineteen cats with abnormally high serum T4 concentrations underwent thyroid scintigraphy using technetium-99m pertechnetate (99mTcO4) before and after 36 +/- 6 days of methimazole administration (approximately 2.5mg PO q 12 h). Thyroid-to-salivary gland ratios (T:S ratios) and percentage thyroidal uptake of injected radioactivity at 20 and 60min after injection of 99mTcO4 were compared before and after methimazole treatment. Serum thyroid stimulating hormone (TSH) concentration was measured before and after methimazole treatment. Quantitatively, there was a positive association between the thyroid uptake of 99mTcO4 and the serum T4 before treatment (r = 0.74-0.83). TSH suppression was present when cats were first evaluated for hyperthyroidism. Methimazole treatment did not relieve TSH suppression in 17 cats. Two cats with unilateral thyroid uptake developed bilateral, asymmetric thyroid uptake of 99mTcO4 after treatment and had the greatest increase in TSH concentration after treatment. Quantitatively, thyroid scintigraphy did not significantly change after methimazole treatment (P>0.1). Evaluation of serum TSH concentration may be helpful in identifying methimazole-induced changes in the scintigraphic features of hyperthyroidism in mildly hyperthyroid cats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号