首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectiveTo evaluate the use of ultrasound for identifying the site for needle puncture and to determine the depth to the epidural space in obese dogs.Study designProspective study in dogs undergoing elective orthopedic surgery.AnimalsA group of seven obese Labrador male dogs aged 6.93 ± 2.56 years and weighing 46.5 ± 4.1 kg (mean ± standard deviation).MethodsThe anesthetic protocol for these dogs included epidural anesthesia. With the dogs anesthetized and positioned in sternal recumbency with the pelvic limbs flexed forward, ultrasound imaging was used to locate the lumbosacral intervertebral space. Intersection of dorsal and transverse lines about the probe identified the point of needle insertion. A 17 gauge, 8.9 cm Tuohy needle was inserted perpendicularly through the skin and advanced to the lumbosacral intervertebral space. The number of puncture attempts was recorded and needle depth was compared with skin to ligamentum flavum distance.ResultsEpidural injection was performed in all dogs at the first attempt of needle insertion. The distance from skin to epidural space was 5.95 ± 0.62 cm measured by ultrasound and 5.89 ± 0.64 cm measured with the Tuohy needle. These measurements were not different (p = 0.26). A highly significant correlation coefficient of 0.966 between measurement techniques was obtained (p < 0.001).Conclusions and clinical relevanceUltrasound imaging identified the point of needle insertion for lumbosacral epidural injection in seven obese dogs. The results indicate that ultrasound can be used to locate the lumbosacral intervertebral space and identify an appropriate point for needle insertion to perform epidural injection.  相似文献   

2.
ObjectiveTo determine the effect of injection speed on epidural pressure (EP), injection pressure (IP), epidural distribution (ED) of solution, and extent of sensory blockade (SB) during lumbosacral epidural anesthesia in dogs.Study designProspective experimental trial.AnimalsTen healthy adult Beagle dogs weighing 8.7 ± 1.6 kg.MethodsGeneral anesthesia was induced with propofol administered intravenously and maintained with isoflurane. Keeping the dogs in sternal recumbency, two spinal needles connected to electrical pressure transducers were inserted into the L6-L7 and the L7-S1 intervertebral epidural spaces for EP and IP measurements, respectively. Bupivacaine 0.5% diluted in iohexol was administered epidurally to each dog via spinal needle at L7-S1 intervertebral space, at two rates of injection (1 and 2 mL minute?1 groups), with a 1-week washout period. Epidural distribution was verified with computed tomography, and SB was evaluated after arousal by pinching the skin with a mosquito hemostatic forceps over the vertebral dermatomes. The results were analyzed according to each injection speed, using paired t- and Wilcoxon signed-rank tests.ResultsMean ± SD of baseline EP and IP values were 2.1 ± 6.1 and 2.6 ± 7.1 mmHg, respectively. Significant differences were observed between 1 and 2 mL minute?1 groups for peak EP (23.1 ± 8.5 and 35.0 ± 14.5 mmHg, p = 0.047) and peak IP (68.5 ± 10.7 and 144.7 ± 32.6 mmHg, p <0.001). However, the median (range) of the ED, 11.5 (4–22) and 12 (5–21) vertebrae, and SB, 3.5 (0–20) and 1 (0–20) dermatomes, values of the two groups were not related to injection speed.Conclusions and clinical relevanceThe EP profile during injection was measured by separating the injection and pressure monitoring lines. The increase in epidural injection speed increased the EP, but not the ED or the SB in dogs.  相似文献   

3.
ObjectiveTo examine the spread of solution in the epidural space of sternally recumbent dogs.Study designProspective experimental trial.AnimalsTen healthy adult Beagle dogs weighing 7.6 ± 1.1 kg.MethodsDogs were anaesthetized with total intravenous propofol infusion, and placed in sternal recumbency. A volume of 0.2 mL kg?1 contrast medium (CM) containing 1% new methylene blue (MB) dye was administered into the lumbosacral epidural space. Left to right lateral radiographs using a horizontal beam were taken every 5 minutes for 45 minutes. The perpendicular height (PH) between floor of the epidural canal of the highest vertebra and that of lumbosacral spinal canal was measured on radiographs. The angle of slope from the injection point toward the highest vertebral floor was measured. Immediately after taking the last radiographic image, dogs were euthanized and a laminectomy was performed from the cervical to lumbar vertebrae for visual evaluation of MB spread. The spread of CM and of MB as counted in number of stained vertebra were compared, and each of these data sets were further compared to PH and angle, using linear regression analyses.ResultsThe PH and angle were (mean ± SD) 3.8 ± 0.8 cm and 14.8 ± 2.8° respectively. The most cranial spread of CM was at 12.7 ± 5.7 (range: C6–L3) vertebrae, and at 14.0 ± 5.4 (range: C6–L2) vertebrae for MB staining. There were no significant correlations between PH and spread of CM (R2 = 0.08) or MB (R2 = 0.13), between angle and spread of CM (R2 = 0.05) or MB (R2 = 0.02), respectively. CM and MB demonstrated proportional relationship (R2 = 0.82, p < 0.001).ConclusionsNo significant inhibitory effect of upward slope on cranial epidural spread of the solution was observed. Other factors may have greater effect on epidural spread in sternally recumbent dogs.  相似文献   

4.
ObjectiveTo compare the cardiovascular effects of four epidural treatments in isoflurane anaesthetised dogs.Study designProspective, randomized. experimental study.AnimalsSix female, neutered Beagle dogs (13.3 ± 1.0 kg), aged 3.6 ± 0.1 years.MethodsAnaesthesia was induced with propofol (8.3 ± 1.1 mg kg?1) and maintained with isoflurane in a mixture of oxygen and air [inspiratory fraction of oxygen (FiO2) = 40%], using intermittent positive pressure ventilation. Using a cross-over model, NaCl 0.9% (P); methadone 1% 0.1 mg kg?1 (M); ropivacaine 0.75% 1.65 mg kg?1 (R) or methadone 1% 0.1 mg kg?1 + ropivacaine 0.75% 1.65 mg kg?1 (RM) in equal volumes (0.23 mL kg?1) using NaCl 0.9%, was administered epidurally at the level of the lumbosacral space. Treatment P was administered to five dogs only. Cardiovascular and respiratory variables, blood gases, and oesophageal temperature were recorded at T-15 and for 60 minutes after epidural injection (T0).ResultsMean overall heart rate (HR in beats minute?1) was significantly lower after treatment M (119 ± 16) (p = 0.0019), R (110 ± 18) (p < 0.0001) and RM (109 ± 13) (p < 0.0001), compared to treatment P (135 ± 21). Additionally, a significant difference in HR between treatments RM and M was found (p = 0.04). After both ropivacaine treatments, systemic arterial pressures (sAP) were significantly lower compared to other treatments. No significant overall differences between treatments were present for central venous pressure, cardiac output, stroke volume, systemic vascular resistance, oxygen delivery and arterial oxygen content (CaO2). Heart rate and sAP significantly increased after treatment P and M compared to baseline (T-15). With all treatments significant reductions from baseline were observed in oesophageal temperature, packed cell volume and CaO2. A transient unilateral Horner’s syndrome occurred in one dog after treatment R.Conclusions and clinical relevanceClinically important low sAPs were observed after the ropivacaine epidural treatments in isoflurane anaesthetised dogs. Systemic arterial pressures were clinically acceptable when using epidural methadone.  相似文献   

5.
ObjectiveTo determine the minimal electrical threshold (MET) necessary to elicit appropriate muscle contraction when the tip of an insulated needle is positioned epidurally or intrathecally at the L5-6 intervertebral space (phase-I) and to determine whether the application of a fixed electrical current during its advancement could indicate needle entry into the intrathecal space (phase-II) in dogs.Study designProspective, blinded study.AnimalsThirteen (phase-I) and seventeen (phase-II) dogs, scheduled for a surgical procedure where L5-6 intrathecal administration was indicated.MethodsUnder general anesthesia, an insulated needle was first inserted into the L5-6 epidural space and secondly into the intrathecal space and the MET necessary to obtain a muscular contraction of the pelvic limb or tail at each site was determined (phase-I). Under similar conditions, in dogs of phase-II an insulated needle was inserted through the L5-6 intervertebral space guided by the use of a fixed electrical current (0.8 mA) until muscular contraction of the pelvic limb or tail was obtained. Intrathecal needle placement was confirmed by either free flow of cerebrospinal fluid (CSF) or myelography.ResultsThe current required to elicit a motor response was significantly lower (p < 0.0001) when the tip of the needle was in the intrathecal space (0.48 ± 0.10 mA) than when it was located epidurally (2.56 ± 0.57). The use of a fixed electrical stimulation current of 0.8 mA resulted in correct prediction of intrathecal injection, corroborated by either free flow of CSF (n = 12) or iohexol distribution pattern (n = 5), in 100% of the cases.Conclusion and clinical relevanceNerve stimulation may be employed as a tool to distinguish epidural from intrathecal insulated needle position at the L5-6 intervertebral space in dogs. This study demonstrates the feasibility of using an electrical stimulation test to confirm intrathecal needle position in dogs.  相似文献   

6.
ObjectiveTo determine the effect of maropitant, an NK-1 receptor antagonist on the minimum alveolar concentration (MAC) of sevoflurane after intravenous and epidural administration to dogs.Study designProspective experimental study.AnimalsSeven, adult, spayed-female dogs (24.8 ± 1.9 kg).MethodsEach dog was anesthetized twice with sevoflurane in oxygen, with at least 10 days separating the anesthetic events. The minimum alveolar concentration (MAC) of sevoflurane was determined using the tail-clamp technique. During the first anesthetic event, the MAC of sevoflurane was determined initially and again after intravenous administration of maropitant (5 mg kg?1) and an infusion (150 μg kg?1 hour?1). During the second anesthetic event, an epidural catheter was advanced to the 4th lumbar vertebra and MAC was determined after administration of saline and maropitant (1 mg kg?1) epidurally. All MAC determinations were done in duplicate. The MAC values were adjusted to sea level and compared using student's t-test.ResultsThe baseline MAC for sevoflurane was 2.08 ± 0.25%. Intravenous maropitant decreased (p < 0.05) MAC by 16% (1.74 ± 0.17%). In contrast, epidural administration of either saline or maropitant did not change (p > 0.05) the MAC (2.17 ± 0.34% and 1.92 ± 0.12%, respectively).Conclusion and clinical relevanceMaropitant decreased the MAC of sevoflurane when administered intravenously to dogs but not after epidural administration.  相似文献   

7.
ObjectiveTo compare, using CT epidurography, the cranial distribution of contrast after epidural injection when saline or air is used for the loss of resistance (LOR) technique in identifying the epidural space.Study designProspective, randomized, cross-over experimental study.AnimalsNine healthy adult Beagle dogs.MethodsUnder general anaesthesia, a spinal needle (22-gauge, 70 mm) was inserted through the lumbosacral space, and the position in the epidural space confirmed using the LOR technique employing either 0.3 mL per dog of saline or of air. Epidurography using CT was performed before and 5, 10 and 20 minutes after epidural injection of 0.2 mL kg?1 of iohexol. The cranial distribution of iohexol was recorded as the number of vertebral segments reached from the seventh lumbar vertebrae.ResultsThe median values in vertebral segments of the cranial distribution at 5, 10 and 20 minutes after epidural injection were 19.5, 20.5 and 21.0 respectively with the saline treatment, and 12.0, 15.0 and 16.0 respectively in the air treatment. At all time points spread of contrast was significantly less with the air treatment. All dogs after air treatment had some air bubbles in the epidural space, and in seven, the spinal cord was moderately compressed by the air. No neurological complications were observed after recovery.Conclusions and clinical relevanceThe use of air for the LOR technique is associated with significantly less spread, uneven cranial distribution of the contrast medium and compression of the spinal cord. It is recommended that saline, and not air, should be used to identify the epidural space by this method.  相似文献   

8.
ObjectiveTo determine the minimal electrical threshold (MET) necessary to elicit muscle contraction of the pelvic limb or tail when an insulated needle is positioned outside (METout) and inside (METin) the lumbosacral epidural space in cats.Study designProspective, blinded study.AnimalsTwelve mixed-breed healthy adult cats, scheduled for a therapeutic procedure where lumbosacral epidural administration was indicated.MethodsUnder general anesthesia, an insulated needle was advanced through tissues of the lumbosacral interspace until its tip was thought to be just dorsal to the interarcuate ligament. An increasing electrical current (0.1 ms, 2 Hz) was applied through the stimulating needle in order to determine the MET necessary to obtain a muscle contraction of the pelvic limb or tail (METout), and then 0.05 mL kg?1 of iohexol was injected. The needle was further advanced until its tip was thought to be in the epidural space. The MET was determined again (METin) and 0.2 mL kg?1 of iohexol was injected. The cats were maintained in sternal position. Contrast medium spread was determined through lateral radiographic projections.ResultsThe radiographic study confirmed the correct needle placement dorsal to the interarcuate ligament in all cats. When the needle was placed ventrally to the interarcuate ligament, iohexol was injected epidurally in ten and intrathecally in two cats. The METout and METin was 1.76 ± 0.34 mA and 0.34 ± 0.07 mA, respectively (p < 0.0001).Conclusion and clinical relevanceNerve stimulation can be employed as a tool to determine penetration of the interarcuate ligament but not the piercing of the dura mater at the lumbosacral space in cats.  相似文献   

9.
ObjectiveTo evaluate the cardiovascular effects of a preload of hydroxyethylstarch 6% (HES), preceding an epidural administration of ropivacaine 0.75% in isoflurane anaesthetized dogs.AnimalsSix female, neutered Beagle dogs (mean 13.3 ± SD 1.0 kg; 3.6 ± 0.1 years).Study designRandomized experimental cross-over study (washout of 1 month).MethodsAnaesthesia was induced with propofol and maintained with isoflurane in oxygen/air. All dogs were anaesthetized twice to receive either treatment HESR (continuous rate infusion [CRI] of 7 mL kg?1 HES started 30 minutes [T-30] prior to epidural administration of ropivacaine 0.75% 1.65 mg kg?1 at T0) or treatment R (no HES preload and similar dose and timing of epidural ropivacaine administration). Baseline measurements were obtained at T-5. Heart rate (HR), mean (MAP), diastolic (DAP) and systolic (SAP) invasive arterial pressures, cardiac output (Lithium dilution and pulse contour analysis) and derived parameters were recorded every 5 minutes for 60 minutes. Statistical analysis was performed on five dogs, due to the death of one dog.ResultsClinically relevant decreases in MAP (<60 mmHg) were observed for 20 and 40 minutes following epidural administration in treatments HESR and R respectively. Significant decreases in MAP and DAP were present after treatment HESR for up to 20 minutes following epidural administration. No significant within-treatment and overall differences were observed for other cardiovascular parameters. A transient unilateral Horner's syndrome occurred in two dogs (one in each treatment). One dog died after severe hypotension, associated with epidural anaesthesia.Conclusions and clinical relevanceA CRI of 7 mL kg?1 HES administered over 30 minutes before epidural treatment did not prevent hypotension induced by epidural ropivacaine 0.75%. Epidural administration of ropivacaine 0.75% in isoflurane anaesthetized dogs was associated with a high incidence of adverse effects in this study.  相似文献   

10.
ObjectiveTo evaluate the analgesic and physiological effects of epidural morphine administered at the sixth and seventh lumbar or the fifth and sixth thoracic vertebrae in dogs undergoing thoracotomy.Study designProspective, randomized, blinded trial.AnimalsFourteen mixed-breed dogs, weighing 8.6 ± 1.4 kg.MethodsThe animals received acepromazine (0.1 mg kg?1) IM and anesthesia was induced with propofol (4 mg kg?1) IV. The lumbosacral space was punctured and an epidural catheter was inserted up to the region between the sixth and seventh lumbar vertebrae (L, n = 6) or up to the fifth or sixth intercostal space (T, n = 8). The dogs were allowed to recover and after radiographic confirmation of correct catheter position, anesthesia was reinduced with propofol IV and maintained with 1.7% isoflurane. Following stabilization of monitored parameters, animals received morphine (0.1 mg kg?1) diluted in 0.9% NaCl to a final volume of 0.25 mL kg?1 via the epidural catheter, and after 40 minutes, thoracotomy was initiated. Heart rate and rhythm, systolic, mean and diastolic arterial pressures, respiratory rate, arterial hemoglobin oxygen saturation, partial pressure of expired CO2 and body temperature were measured immediately before the epidural administration of morphine (0 minute) and every 10 minutes during the anesthetic period. The Melbourne pain scale and the visual analog scale were used to assess post-operative pain. The evaluation began 3 hours after the epidural administration of morphine and occurred each hour until rescue analgesia.ResultsThere were no important variations in the physiological parameters during the anesthetic period. The post-operative analgesic period differed between the groups, being longer in T (9.9 ± 1.6 hours) compared with L (5.8 ± 0.8 hours).ConclusionsThe use of morphine, at a volume of 0.25 mL kg?1, administered epidurally over the thoracic vertebrae provided longer lasting analgesia than when deposited over the lumbar vertebrae.Clinical relevanceThe deposition of epidural morphine provided longer lasting analgesia when administered near to the innervation of the injured tissue without increasing side effects.  相似文献   

11.
ObjectiveTo evaluate the volume effect of local anesthetic solution on thoracic epidural analgesia in dogs.Study designProspective, experimental trial.AnimalsFive healthy adult Beagle dogs weighing 9.7 ± 1.3 kg.MethodsA catheter was inserted into the seventh thoracic epidural space using a lumbosacral approach, and secured with suture under total intravenous (IV) anesthesia with propofol. Each dog was administered four volume treatments (0.05, 0.10, 0.15 and 0.20 mL kg−1) of 2% lidocaine via the catheter at 12 hour intervals. In every treatment, dogs were re-anesthetized with propofol (6 mg kg−1, IV) and isoflurane, and received iohexol at each volume to visualize the epidural distribution (ED) through computed tomography. Three hours after epidurography, when dogs had recovered from anesthesia, the appropriate volume of lidocaine was injected through the catheter, and sensory blockade (SB) in dermatomes was evaluated by pinching with a mosquito forceps. Results were presented as median (range), and the volume effect on ED and SB was analyzed with one-way Kruskal–Wallis anova.ResultsIn proportion to volumes (0.05, 0.10, 0.15 and 0.20 mL kg−1), there were significant increases in the extent of ED from 7.4 (5.5–9.0) to 10.4 (8.0–12.0), 13.2 (12.5–13.0), and 15.2 (13.0–18.0) vertebrae, respectively, p < 0.001, and in SB from 2.7 (1.0–5.0) to 6.8 (4.5–10.5), 9.9 (6.5–13.0), and 13.1 (11.0–15.0) dermatomes, respectively, p < 0.001. Unilateral ED and SB were observed in all treatments with various grades, and this distribution was more frequent in the low volume treatments. In the high volume treatments, temporary complications including Horner's syndrome, ataxia, paraplegia, depression, stupor, and intermittent cough occurred often.Conclusions and clinical relevanceThe increase in volume of local anesthetic solution improved SB by resulting in more consistent bilateral dermatome blockade as well as an extended blockade. However, caution should be exerted, as higher volume injections of lidocaine caused side effects in all dogs.  相似文献   

12.
ObjectiveTo investigate the cardiovascular effects of epidural romifidine in isoflurane-anaesthetized dogs.Study designProspective, randomized, blinded experiment.AnimalsA total of six healthy adult female Beagles aged 1.25 ± 0.08 years and weighing 12.46 ± 1.48 (10.25–14.50) kg.MethodsAnaesthesia was induced with propofol (6–9 mg kg?1) and maintained with 1.8–1.9% end-tidal isoflurane in oxygen. End-tidal CO2 was kept between 35 and 45 mmHg (4.7–6.0 kPa) using intermittent positive pressure ventilation. Heart rate (HR), arterial blood pressure and cardiac output (CO) were monitored. Cardiac output was determined using a LiDCO monitor and the derived parameters were calculated. After baseline measurements, either 10 μg kg?1 romifidine or saline (total volume 1 mL 4.5 kg?1) was injected into the lumbosacral epidural space. Data were recorded for 1 hour after epidural injection. A minimum of 1 week elapsed between treatments.ResultsAfter epidural injection, the overall means (± standard deviation, SD) of HR (95 ± 20 bpm), mean arterial blood pressure (MAP) (81 ± 19 mmHg), CO (1.63 ± 0.66 L minute?1), cardiac index (CI) (2.97 ± 1.1 L minute?1 m?2) and stroke volume index (SI) (1.38 ± 0.21 mL beat?1 kg?1) were significantly lower in the romifidine treatment compared with the overall means in the saline treatment [HR (129 ± 24 bpm), MAP (89 ± 17 mmHg), CO (3.35 ± 0.86 L minute?1), CI (6.17 ± 1.4 L minute?1 m?2) and SI (2.21 ± 0.21 mL beat?1 kg?1)]. The overall mean of systemic vascular resistance index (SVRI) (7202 ± 2656 dynes seconds cm?5 m?2) after epidural romifidine injection was significantly higher than the overall mean of SVRI (3315 ± 1167 dynes seconds cm?5 m?2) after epidural saline injection.ConclusionEpidural romifidine in isoflurane-anaesthetized dogs caused significant cardiovascular effects similar to those reportedly produced by systemic romifidine administration.Clinical relevanceSimilar cardiovascular monitoring is required after epidural and systemically administered romifidine. Further studies are required to evaluate the analgesic effects of epidural romifidine.  相似文献   

13.
ObjectiveTo evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction.Study designProspective, experiment.AnimalsSix male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg).MethodsAnimals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2–L5), thoracic (T5–T10) and cervical (C4–C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD.ResultsThe catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found.Conclusion and clinical relevancePlacement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia.  相似文献   

14.
ObjectiveTo determine the impact of epidural phentolamine on the duration of anaesthesia following epidural injection of lidocaine–epinephrine.Study designBlinded randomized experimental study.AnimalsA group of 12 adult ewes weighing 25.7 ± 2.3 kg and aged 8–9 months.MethodsAll sheep were administered epidural lidocaine (approximately 4 mg kg–1) and epinephrine (5 μg mL–1). Of these, six sheep were randomized into three epidural treatments, separated by 1 week, administered 30 minutes after lidocaine–epinephrine: SAL: normal saline, PHE1: phentolamine (1 mg) and PHE2: phentolamine (2 mg). The other six sheep were administered only epidural lidocaine–epinephrine: treatment LIDEP. Each injection was corrected to 5 mL using 0.9% saline. Noxious stimuli were pinpricks with a hypodermic needle and skin pinch with haemostatic forceps to determine the onset and duration of sensory and motor block. Heart rate, noninvasive mean arterial pressure (MAP), respiratory rate and rectal temperature were recorded.ResultsThe onset times were not different among treatments. Duration of sensory block was significantly shorter in SAL (57.5 ± 6.2 minutes), PHE1 (60.7 ± 9.0 minutes) and PHE2 (62.0 ± 6.7 minutes) than in LIDEP (81.7 ± 13.4 minutes) (p < 0.05). Duration of motor blockade was significantly shorter in PHE1 (59.4 ± 5.4 minutes) and PHE2 (54.3 ± 4.0 minutes) than in SAL (84.8 ± 7.0 minutes) and LIDEP (91.5 ± 18.2 minutes) (p < 0.01). MAP in PHE2 was decreased at 10 minutes after administration of phentolamine (p < 0.05).Conclusion and clinical relevanceEpidural administration of 5 mL normal saline after epidural injection of lidocaine–epinephrine reduced the duration of sensory but not motor block in sheep. Epidural administration of phentolamine diluted to the final volume of 5 mL diminished both the duration of sensory and motor block in sheep administered epidural lidocaine–epinephrine.  相似文献   

15.
16.
ObjectiveTo test the compensatory role of endothelin-1 when acute blood loss is superimposed on anaesthesia, by characterizing the effect of systemic endothelin receptor subtype A (ETA) blockade on the haemodynamic and hormonal responses to haemorrhage in dogs anaesthetized with xenon/remifentanil (X/R) or isoflurane/remifentanil (I/R).Study designProspective experimental randomized controlled study.AnimalsSix female Beagle dogs, 13.4 ± 1.3 kg.MethodsAnimals were anaesthetized with remifentanil 0.5 μg kg?1 minute?1 plus either 0.8% isoflurane (I/R) or 63% xenon (X/R), with and without (Control) the systemic intravenous endothelin receptor subtype A antagonist atrasentan (four groups, n = 6 each). After 60 minutes of baseline anaesthesia, the dogs were bled (20 mL kg?1) over 5 minutes and hypovolemia was maintained for 1 hour. Continuous haemodynamic monitoring was performed via femoral and pulmonary artery catheters; vasoactive hormones were measured before and after haemorrhage.ResultsIn Controls, systemic vascular resistance (SVR), vasopressin and catecholamine plasma concentrations were higher with X/R than with I/R anaesthesia at pre-haemorrhage baseline. The peak increase after haemorrhage was higher during X/R than during I/R anaesthesia (SVR 7420 ± 867 versus 5423 ± 547 dyne seconds cm?5; vasopressin 104 ± 23 versus 44 ± 6 pg mL?1; epinephrine 2956 ± 310 versus 177 ± 99 pg mL?1; norepinephrine 862 ± 117 versus 195 ± 33 pg mL?1, p < 0.05). Haemorrhage reduced central venous pressure from 3 ± 1 to 1 ± 1 cmH2O (I/R, ns) and from 8 ± 1 to 5 ± 1 cmH2O (X/R, p < 0.05), but did not reduce mean arterial pressure, nor cardiac output. Atrasentan did not alter the haemodynamic and hormonal response to haemorrhage during either anaesthetic protocol.Conclusions and clinical relevanceSelective ETA receptor blockade with atrasentan did not impair the haemodynamic and hormonal compensation of acute haemorrhage during X/R or I/R anaesthesia in dogs.  相似文献   

17.
ObjectiveTo evaluate perfusion index (PI) as a noninvasive tool to determine effectiveness and onset of epidural anesthesia in dogs.Study designProspective clinical trial.AnimalsA total of 21 adult dogs, aged 6.5 ± 3 years and weighing 34.9 ± 6.4 kg, undergoing a tibial plateau leveling osteotomy.MethodsDogs were premedicated intramuscularly with acepromazine (0.03 mg kg–1) and hydromorphone (0.1 mg kg–1) and anesthetized with intravenous propofol (to effect) and isoflurane in oxygen. A surface transflectance probe was secured to the tail base to monitor PI and a dorsal pedal artery catheter was placed for invasive blood pressure monitoring. A lumbosacral epidural was performed with the dog in sternal recumbency. Dogs were randomly assigned for inclusion of epidural morphine (0.1 mg kg–1) or morphine (0.1 mg kg–1) and lidocaine (4 mg kg–1). PI was recorded following instrumentation of each dog just prior to the epidural (baseline), at 10 minute intervals for 30 minutes, before and after the surgical skin incision and before and after completion of the osteotomy. Physiological variables and end-tidal isoflurane were recorded at the same time points.ResultsThere was no significant difference in PI between the groups at any time point. There was a significant change in end-tidal isoflurane before and after the skin incision in the epidural morphine and epidural morphine–lidocaine groups (p = 0.04, p = 0.05, respectively) and before and after the osteotomy in each group for heart rate (p = 0.001, p = 0.04), diastolic (p = 0.01, p = 0.01) and mean arterial blood pressure (p = 0.03, p = 0.05).Conclusions and clinical relevancePI did not provide an objective means for determining the onset or effectiveness of epidural anesthesia in anesthetized dogs and alternate methods of noninvasive assessment should be investigated.  相似文献   

18.
ObjectiveTo compare the nerve stimulation test (group NS) with the running-drip method (group RUN) for successful identification of the sacrococcygeal (SCo) epidural space prior to drug administration in dogs.AnimalsA total of 62 dogs.Study designA randomized clinical study.MethodsDogs requiring an epidural anaesthetic as part of the multimodal anaesthetic plan were randomly allocated to one of the two study groups. In group NS, the epidural space was located using an insulated needle connected to a nerve stimulator; in group RUN, the epidural space was identified using a Tuohy needle connected to a fluid bag elevated 60 cm above the spine via an administration set. The success of the technique was assessed 5 minutes after epidural injection by the disappearance of the patella reflex. Data were checked for normality, nonparametric data was analysed using a Mann–Whitney U test and success rate was analysed using a Fisher’s exact test. The significance level was set at p < 0.05, and the results are presented in absolute values, percentage (95% confident interval) and median (range).ResultsThe success in identification of the epidural space did not differ between groups NS and RUN [87.1% (70.2%–96.4%) versus 90.3% (74.2%–98%); p = 1.000]. The time required for identification of the epidural space was shorter in group RUN [26 (15–53) seconds] than in group NS [40 (19–137) seconds] (p = 0.0225). No other differences were found in any studied variables.Conclusionand clinical relevance In this study, both RUN and NS techniques were successful in identifying the epidural space at the SCo intervertebral space. RUN requires no specialised equipment, can be performed rapidly and offers an alternative to the NS for use in general veterinary practice.  相似文献   

19.

Objective

To compare the effects of epidural injection of three volumes of lidocaine injected at the third (T3) or eleventh thoracic vertebra (T11) in conscious dogs to induce thoracic epidural anesthesia (TEA) and to measure the epidural dispersion of iohexol under similar conditions.

Study design

Prospective crossover experiment.

Animals

A group of five Beagle dogs weighing 10.4 ± 0.5 kg (mean ± standard deviation).

Methods

Each dog was anesthetized twice, separated by 1 week, for inserting an epidural catheter at the lumbosacral space and advancing the tip to T3 (treatment TEAT3) or T11 (treatment TEAT11). For each treatment, three volumes of 2% lidocaine (0.05, 0.10 and 0.20 mL kg–1) were administered at 24 hour intervals, and sensory blockade (SB) of dermatomes was estimated by pinching the skin with mosquito forceps. Under identical conditions of injection volume and site, iohexol was administered 3 hours after lidocaine injection to identify epidural distribution (ED) using computed tomography. The effects of injection site and volume on SB of thoracic dermatomes and ED were analyzed using a linear mixed model (p < 0.05).

Results

Thoracic SB and ED significantly increased as the volume increased (p < 0.001 and p < 0.001, respectively), and significantly decreased in TEAT3 than in TEAT11 (p = 0.011 and p = 0.002, respectively). Cervical SB was obtained in three of five dogs in TEAT3 and two of five dogs in TEAT11 injected with 0.20 mL kg–1. One dog showed temporary inspiratory stridor probably caused by bilateral laryngeal paralysis, but no hypoxia.

Conclusions and clinical relevance

TEA induced at T3 produced less thoracic SB than did TEA at T11 with the same volumes of lidocaine. The cervical SB obtained with the highest volume of lidocaine may increase the risk of laryngeal paralysis and pulmonary aspiration.  相似文献   

20.
ObjectivesTo assess the accuracy of the ‘hanging drop method’ for identifying the extradural space in anaesthetized dogs positioned in sternal or lateral recumbency.Study designProspective randomized-experimental study.AnimalsSeventeen clinically healthy adult dogs, 10 females and seven males weighing 8.4–26.2 kg.MethodsDogs were positioned in either sternal (n = 8) or lateral (n = 9) recumbency under general anaesthesia. A 20 SWG spinal needle pre-filled with 0.9% saline was advanced through the skin into the lumbosacral extradural space and the response of the saline drop recorded, i.e. whether it: 1) was aspirated from the hub into the needle; 2) remained within the hub, or 3) moved synchronously with i) spontaneous respiration, ii) heart beat or iii) manual lung inflation. The position of the needle tip was ultimately determined by positive contrast radiography.ResultsOne dog positioned in lateral recumbency was excluded from the study because bleeding occurred from the needle hub. Saline was aspirated into the needle in seven of eight dogs held in sternal recumbency but in none of the dogs positioned in lateral recumbency. Accurate needle tip placement in the extradural space was confirmed by positive contrast radiography in all dogs.Conclusion and clinical relevanceThe ‘hanging drop’ method, when performed with a spinal needle, appears to be a useful technique for identifying the location of the extradural space in anaesthetized medium-sized dogs positioned in sternal, but not in lateral recumbency. The technique may yield ‘false negative’ results when performed in dogs positioned in sternal recumbency.  相似文献   