首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The objective of this study was to determine if plasma iohexol clearance, computed by a 1-compartment model defined by 3 plasma samples. was an accurate measure of glomerular filtration rate (GFR) in dogs. Twenty-two adult Beagle dogs of both genders were studied. Ten dogs had intact kidneys, and 12 dogs had surgically reduced renal mass. A bolus injection of iohexol was made, and blood was obtained for plasma iohexol assay after 120, 180, and 240 minutes. Plasma was analyzed for iohexol concentration by means of 3 assay methods: chemical, high-performance liquid chromatography (HPLC), and inductively coupled plasma emission spectroscopy (ICP). Urinary clearance of exogenous creatinine was used to measure GFR for three 30-minute periods occurring between 150 and 240 minutes after iohexol injection. Plasma clearance of iohexol and renal clearance of creatinine were compared by linear regression analysis and by limits of agreement techniques. Plasma iohexol clearance and urinary exogenous creatinine clearance were significantly correlated (chemical R2 = .90; HPLC R2 = .96; and ICP R2 = .96). The 1-compartment iohexol clearance:exogenous creatinine clearance ratios were 1.04 +/- 0.17, 1.05 +/- 0.14, and 1.10 +/- 0.15 for the chemical, HPLC, and ICP methods of assay, respectively, indicating that plasma iohexol clearance slightly overestimated GFR. Assuming a +/- 2 standard deviation interval for error, corrected plasma iohexol clearance measured GFR with +/-34% accuracy for the chemical, +/-26% accuracy for the HPLC, and +/-27% accuracy for the ICP method. These results indicate that plasma iohexol clearance should have utility for detection of renal dysfunction earlier in the course of progressive renal disease than is possible with measurement of plasma creatinine or urea concentrations.  相似文献   

2.
Plasma clearance of creatinine was evaluated for assessment of glomerular filtration rate (GFR) in dogs. In 6 healthy dogs (Experiment 1), we determined 24-hour urine clearance of endogenous creatinine, plasma, and urine clearances of exogenous creatinine administered at 40, 80, and 160 mg/kg in a crossover design (linearity study), plasma iothalamate clearance, and plasma and urine clearances of 14C-inulin. In Experiment 2, plasma creatinine and iothalamate clearances were compared, and a linearity study was performed as for Experiment 1 in 6 dogs with surgically induced renal impairment. Experiment 3 compared plasma creatinine clearance with plasma iothalamate clearance before and 3 weeks after induction of moderate renal impairment in 6 dogs. Plasma creatinine clearances were calculated by both noncompartmental and compartmental analyses. In Experiment 1, plasma inulin clearance was higher (P < .001) than other clearance values. Plasma creatinine clearances at the 3 dose rates did not differ from urine inulin clearance and each other. In Experiment 2, plasma creatinine clearances were about 14% lower than plasma iothalamate clearance (P < .05). In Experiment 3, decreases in GFR assessed by plasma clearances of iothalamate and creatinine were similar. Renal failure decreased the daily endogenous input rate of creatinine by 25%. Limiting sampling strategies for optimizing GFR calculation were proposed, allowing an error lower than 6.5% with 4 blood samples. These results suggest that determination of plasma creatinine clearance by a noncompartmental approach offers a reliable, inexpensive, rapid, and convenient means of estimating GFR in routine practice.  相似文献   

3.
Methods of renal clearance to measure glomerular filtration rate (GFR) were compared with plasma creatinine concentration in clinically normal and partially nephrectomized dogs. Glomerular filtration rate was measured by use of a simple 24-hour creatinine clearance method in 36 normal female Beagles. Mean values were 57.6 +/- 9.3 ml/minute/m2 of body surface or 3.7 +/- 0.77 ml/minute/kg of body weight. Variability of this measurement was considerable, as determined in 4 dogs studied on 4 consecutive days. Glomerular filtration rate was measured in the same 36 dogs while they were under anesthesia, using short clearance periods to compare inulin and endogenous creatinine clearance. Mean values for inulin were 41.8 +/- 13.9 ml/minute/m2 of body surface. A close agreement with creatinine clearance was found (correlation coefficient, 0.998). Mean plasma creatinine concentration was 0.82 (range, 0.5--1.0) mg/100 ml. The value of GFR measurement compared with plasma creatinine concentration was determined in 10 dogs after 75% nephrectomy. Sixty days after partial nephrectomy, GFR was reduced to 61% of normal. Mean plasma creatinine and blood urea nitrogen were 1.2 +/- 0.14 mg/100 ml and 20.4 +/- 7.1 mg/100 ml, respectively. Thus, the detection of reduced renal function may be uncertain when plasma creatinine or blood urea nitrogen are used as a means of evaluating renal function. It was concluded that a simple method of creatinine clearance is a sensitive and useful measurement to detect early or borderline reduction in glomerular function.  相似文献   

4.
The suitability of 99mTc-diethylenetriaminepentaacetic acid (99mTc-DTPA) as an agent to assess glomerular filtration rate (GFR) in dogs was evaluated. Glomerular filtration rates of 12 healthy dogs were determined on the basis of creatinine and/or inulin clearance. Glomerular filtration rates also were determined in 7 dogs after induction of acute renal failure by administration of amphotericin B. The healthy dogs and the amphotericin B-treated dogs were given 99mTc-DTPA (1 to 2 mCi) IV. The percentage of the 99mTc-DTPA dose in the kidneys (percentage dose) was determined, with background activity subtracted from total activity at 15-s intervals 0 to 6 minutes after 99mTc-DTPA infusion. Linear regression analyses (LRA) were performed to determine whether the percentage dose at various time intervals after injection correlated with GFR calculated on the basis of creatinine and inulin clearance data. One to 3 minutes after 99mTc-DTPA administration appeared to be the best period for analysis of the data. The percentage dose of 99mTc-DTPA (corrected for kidney depth differences) was determined and LRA against GFR were performed. The percentage dose correlated better with inulin clearance (r = 0.94) than with endogenous creatinine clearance (r = 0.83). Only inulin clearance correlations improved with kidney depth correction. The LRA was used to derive an equation that could be used to calculate GFR on the basis of the percentage dose. The equation derived from inulin regression was: GFR (milliliter/minute/kilogram of body weight) = 0.194 (depth-corrected percentage dose)--0.37; the equation derived from the creatinine regression was: GFR (milliliter/minute/kilogram) = 0.171 (depth-corrected percentage dose)-0.15.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
A suitable method in the routine veterinary practice for the quantitative determination of the glomerular filtration rate (GFR) in dogs and cats has not been available until to date. Therefore, we modified the known plasma clearance model (=P-CL). The resulting P-CLterminal was assessed concerning its diagnostic value. P-CL of exogenous creatinine (P-CLcrea) and of inulin were determined in dogs (n=12, Beagle, 6 months of age) and cats (n=11, Domestic Short Hair, 14 months of age). The marker substances were administered as a bolus injection. In fasted dogs, P-CLcrea was 84.3 +/- 14.85 ml/min/m2 after a creatinine dose of 2.4 g/m2. An electrolyte infusion during the clearance determination did not alter the resulting values (p>0.05). In fasted cats, P-CLcrea was 54.7 +/- 5.8 ml/min/m2 (creatinine dose 2.0 g/m2). The inulin clearance, determined at the same time, was 104.5 +/- 19.81 ml/min/m2. Feeding the cats just before and during the test increased P-CL of both markers significantly (p<0.05). In order to adapt the clearance method for diagnostic assessment of GFR in the small animal practice, we aimed at minimizing the number of required blood samples (3 instead of 7 or more) and introduced the modified exogenous creatinine clearance (P-CLterminal). These values determined were 108.4 +/- 20.81 ml/min/m2 in fasted dogs and 66.3 +/- 11.81 ml/min/m2 in fasted cats. An electrolyte infusion (dogs) and feeding (cats) had the same effect on P-CLterminal values as described above for P-CL. In conclusion,the modified exogenous creatinine clearance is a suitable renal function test for the early diagnosis of renal disease in dogs and cats presented in small animal practices.  相似文献   

6.
OBJECTIVE: To evaluate accuracy of measuring plasma clearance of inulin as an alternative renal function test for estimation of glomerular filtration rate (GFR) in cats. ANIMALS: 10 cats, first studied with intact kidneys and subsequently studied following partial nephrectomy. PROCEDURE: Clearance studies were performed in 10 clinically normal cats; those same cats then underwent partial nephrectomy, and clearance studies were performed again. Plasma concentration of inulin was determined after administration at 50 mg/kg of body weight to cats while renally intact and 45 mg/kg after the partial nephrectomy. Plasma clearance of inulin (PCin) was determined by dividing the dose by the area under the plasma inulin concentration versus time curve. Results for PCin were compared with values obtained simultaneously for urinary clearance of exogenously administered creatinine (Ccr), a widely accepted method for measurement of GFR in cats with intact kidneys and cats with reduced renal mass. RESULTS: Results of PCin were strongly correlated (r2 = 0.912, P < 0.001) with Ccr. Repeatability of determination of PCin was similar to that of Ccr. Sensitivity and specificity of PCin were superior and equivalent to that of Ccr, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Determination of PCin provides a reliable estimate of GFR in cats and is a promising alternative to determining Ccr in cats.  相似文献   

7.
The purpose of this study was to evaluate simplified methods for iohexol plasma clearance estimation in dogs and cats. Serial blood samples were taken before and 5, 20, 40, 60, 80, 100, 120, 150, 180, and 240 minutes after a bolus injection of iohexol in 51 dogs and 25 cats. Iohexol plasma concentration was determined with X-ray fluorescence. Clearance was calculated by dividing the injected dose by the area under the plasma tracer elimination curve estimated with a 2-compartment pharmacologic model. Clearance was normalized to body surface area (BSA). The 10-point clearance was used as a reference for the evaluation of simplified methods. A 2-sample method based on a single exponential fit and a single-sample method based on a linear quadratic model were investigated. Simplified methods were evaluated by calculating the standard deviation of the difference (SDD) between the clearances obtained with the simplified methods and the 10-point reference method. All combinations of sampling times were evaluated. The best sampling times were chosen for dogs and cats as the ones yielding the lowest SDD. Linear regression analysis was performed between the reference method and the optimized simplified methods. The best combination of time for the 2-sample method was 5 and 120 minutes in dogs and 20 and 180 minutes in cats. The best time for sampling in the single-sample method was 120 minutes in dogs and 80 minutes in cats. Plasma clearance of iohexol can be estimated in dogs and cats from 1 or 2 blood samples with a reasonable margin of error.  相似文献   

8.
Glomerular filtration rate (GFR) was determined in 53 cats using an inulin single-injection method. Thirty healthy young adult cats were used to establish normal values. The procedure was also used in 23 cats that were either older than 10 years or had borderline serum creatinine levels. The total clearance was calculated from the decay of the serum inulin concentration after injection of 3000 mg/m(2)body surface area using a two-compartment model. Concomitant inulin and iohexol clearance in nine cats showed excellent correlation between the two methods. Calculated normal values for GFR in 30 healthy cats were 35.9-58.5 (median 46.0) ml/min/m(2)or 2.07-3.69 (median 2.72) ml/min/kg. A few cats with normal creatinine or blood urea nitrogen levels were detected as having reduced GFR and therefore being in a state of early renal dysfunction. The study indicates that single-injection inulin clearance is a valuable tool for routine GFR measurement in cats. An "inulin excretion test" using only one blood sample 3h after the administration of 3000 mg/m(2)body surface area could prove an attractive alternative for the assessment of renal function in daily practice.  相似文献   

9.
OBJECTIVE: To determine the effect of number of blood samples and sampling times on plasma clearance of technetium Tc 99m pentetate (Tc99mP) and orthoiodohippurate sodium I 131(OIH). ANIMALS: 20 dogs and 14 cats. PROCEDURE: Plasma clearances of OIH and Tc99mP were calculated by use of a 2-compartment model, on the basis of a 12-point curve as a reference method. Plasma clearance was calculated by use of all possible combinations of 4 to 11 samples. Time schedule yielding the smallest difference from the reference method was considered to be optimal. Regression analysis was performed between the 12-point model and models using a reduced number of samples. RESULTS: SD of the difference between the 12-point clearance and the models with reduced numbers of samples increased when the number of samples decreased. The SD of the difference between 12-point clearance and 4-point clearance was 4.17 ml/min for OIH and 0.94 ml/min for Tc99mP in dogs and 0.45 ml/min for OIH and 0.11 ml/min for Tc99mP in cats. Optimal schedules were distributed logarithmically and included an early sample at 5 or 10 minutes, a late sample at 2.5, 3, 4, or 5 hours for OIH, and a late sample at 4 or 5 hours for Tc99mP. CONCLUSIONS AND CLINICAL RELEVANCE: Plasma clearances of OIH and Tc99mP can be accurately calculated in dogs and cats by use of a single-injection 2-compartment pharmacologic model with a reduced number of blood samples, resulting in an acceptable margin of error.  相似文献   

10.
The effectiveness of technetium 99m-labeled diethylenetriaminepentaacetic acid (99mTc DTPA) to assess renal function in 13 dogs with suspected renal disease was evaluated. Glomerular filtration rates (actual GFR) were determined on the basis of endogenous creatinine clearance. Predicted GFR were determined by using 99mTc DTPA within 72 hours after the determination of creatinine clearance. The percentage of an IV administered dose of 99mTc DTPA in the kidneys (percentage dose) was determined. Two equations were used to calculate predicted GFR, which were derived from previously reported linear regression analysis of inulin (In) and creatinine (Cr) GFR vs percentage dose 99mTc DTPA in dog kidneys. The correlations of actual GFR vs predicted GFR (In) and actual GFR vs predicted GFR (Cr) were both r = 0.92. The dogs' mean actual GFR was 1.73 +/- 1.35 ml/min/kg. Their mean predicted GFR (In) and predicted GFR (Cr) were 1.92 +/- 1.42 ml/min/kg and 1.85 +/- 1.27 ml/min/kg, respectively. Therefore, 99mTc DTPA can be used with high accuracy as an agent to predict GFR in dogs with suspected renal disease. The procedure for determining GFR by use of nuclear medicine was rapid and noninvasive and appeared to induce little stress in the animals evaluated.  相似文献   

11.
OBJECTIVES: To determine effects of commonly used diuretic treatments on glomerular filtration rate (GFR), renal blood flow (RBF), and urine output (UO) and compare 2 methods of GFR measurement in healthy awake cats. ANIMALS: 8 healthy cats. PROCEDURE: In a randomized crossover design, cats were randomly allocated to 4 groups: control; IV administration of fluids; IV administration of fluids and mannitol; and IV administration of fluids, dopamine, and furosemide. Inulin and para-aminohippuric acid were used for determination of plasma clearance for GFR and RBF, respectively. Plasma clearance of technetium-Tc-99m-diethylenetriaminepentacetic acid (99mTc-DTPA) was also used for GFR determination. RESULTS: Furosemide-dopamine induced the largest UO, compared with other groups. Both mannitol and fluid therapy increased RBF, compared with the control group. Mannitol, and not fluid therapy, increased RBF, compared with furosemide-dopamine. There were significant differences in GFR values calculated from 99mTc-DTPA and inulin clearances between the 2 groups. In all groups, use of 99mTc-DTPA caused underestimation of GFR, compared with use of inulin. CONCLUSIONS AND CLINICAL RELEVANCE: In healthy awake cats, administration of furosemide-dopamine did not increase GFR or RBF despite increased UO. Fluid therapy and fluid therapy plus mannitol improved RBF. Determination of GFR by use of 99mTc-DTPA cannot always be substituted for inulin clearance when accurate measurement is required.  相似文献   

12.
The purpose of the study was to compare the disposition of pharmacologic markers for cytochrome P-450 (CYP) metabolism, glomerular filtration rate (GFR), and extracellular (ECFV) and total body fluid volumes (TBFV) of Greyhounds and Beagles. Six healthy Greyhound and six healthy Beagle dogs were studied. Antipyrine, a marker for CYP metabolism and TBFV, and inulin, a marker for the GFR and ECFV, were administered i.v. Samples were collected at predetermined times and plasma was analyzed by validated high-pressure liquid chromatography (HPLC) methods. There were no differences in the disposition or pharmacokinetic parameters for inulin between the dog breeds. However, the clearance of antipyrine (mean = 8.33 mL/min/kg) in Greyhounds was significantly slower than Beagles (13.42 mL/min/kg, P = 0.004). The volume of distribution of antipyrine was significantly larger in Greyhounds (0.789 L/kg) than in Beagles (0.644 L/kg, P = 0.01). The half-life of antipyrine was significantly longer in Greyhounds (1.09 h) compared with Beagles (0.55 h, P = 0.002). The in vitro plasma protein binding of antipyrine was significantly less in Greyhounds (28%) compared with Beagles (40.3%, P = 0.008). Greyhounds exhibited significantly slower CYP metabolism, higher TBFV, and lower in vitro protein binding of antipyrine compared with Beagles. No differences in GFR or ECFV were found.  相似文献   

13.
The purpose of this study was to evaluate simplified methods for estimation of Technetium Tc 99m (99mTc)-pentetate and orthoiodohippurate I 131 (131I-OIH) plasma clearance in dogs and cats with 1 and 2 blood samples. Plasma clearances were calculated after a bolus injection of 1.85-11.1 MBq of 99mTc-pentetate and 131I-OIH with a 2-compartment model based on a 12-point curve as a reference method in 21 dogs and 18 cats. Three 2-sample and 3 single-sample methods were investigated. The method yielding the smallest standard deviation of the difference between the reference method and the simplified method was selected as the optimal one. Linear regression analysis was performed between the reference method and the simplified method and coefficient of determination (R2) was calculated. For 99mTc-pentetate plasma clearance, the optimal 2-sample method was the one with a mono-compartment model with samples taken at specific times. For 131I-OIH plasma clearance, the estimation was improved slightly by raising the clearance calculated with a mono-compartment model to the power of an empirically determined parameter. The optimal single-sample method was the one with a linear quadratic regression between the volume of distribution of the tracer at a specific time and the clearance calculated with 12 samples. Two-sample methods performed significantly better than did single-sample methods. The conclusion is made that 99mTc-pentetate and 131I-OIH plasma clearances can be estimated in dogs and cats with 1 or 2 blood samples with a reasonable margin of error compared to plasma clearances calculated with a 2-compartment model and 12 blood samples.  相似文献   

14.
The goals of this study were to determine if the glomerular filtration rate (GFR) in dogs could be estimated by plasma inulin clearance and/or infusion inulin clearance analyses without urine collection, and to compare these results with GFR values obtained by urinary inulin clearance analysis. The dogs included in this study were healthy 20 beagles. Inulin clearance values were obtained by urinary inulin clearance, infusion inulin clearance, and plasma inulin clearance techniques. Urinary inulin clearance was 4.09±0.52 ml min(-1) kg(-1) (body weight); infusion inulin clearance, 4.01±0.49 ml min(-1) kg(-1); and plasma inulin clearance, 4.14±0.66 ml min(-1) kg(-1). The urinary inulin clearance was strongly correlated with infusion inulin clearance and weakly correlated with plasma inulin clearance. The GFR for dogs can be estimated by infusion and plasma inulin clearance analyses by blood sampling alone, without urine collection.  相似文献   

15.
OBJECTIVE: To determine whether administration of the nonsteroidal anti-inflammatory drugs meloxicam or carprofen to healthy dogs that were subsequently anesthetized and subjected to painful electrical stimulation has adverse effects on renal function as measured by glomerular filtration rate (GFR) and evaluation of serum concentrations of urea and creatinine. ANIMALS: 6 male and 6 female healthy young-adult Beagles. PROCEDURE: A study was conducted in accordance with a randomized crossover Latin-square design. One of 3 treatments (saline [0.9% NaCl] solution, 0.2 mg of meloxicam/kg, or 4.0 mg of carprofen/kg) was administered i.v. 1 hour before anesthesia was induced by use of drugs in accordance with a standard anesthetic protocol (butorphanol tartrate and acepromazine maleate as preanesthetic medications, ketamine hydrochloride and diazepam for induction, and maintenance with isoflurane). Anesthetized dogs were subjected to intermittent electrical stimulation for 30 minutes. Direct, mean arterial blood pressure; heart rate; and respiratory rate were monitored. End-tidal isoflurane concentration was maintained at 1.5 times the minimum alveolar concentration. The GFR, as measured by plasma clearance of 99mTc-diethylenetriaminepentaacetic acid, and serum concentrations of serum and creatinine were determined 24 hours after induction of anesthesia. RESULTS: Neither meloxicam nor carprofen significantly affected GFR or serum concentrations of urea and creatinine, compared with values for the saline treatment. CONCLUSIONS AND CLINICAL RELEVANCE: When administered 1 hour before onset of anesthesia and painful electrical stimulation, meloxicam or carprofen did not cause clinically important alterations of renal function in young healthy dogs.  相似文献   

16.
Comparison of four methods of estimating glomerular filtration rate in cats   总被引:2,自引:0,他引:2  
Four methods of evaluating renal function were performed in 6 cats anesthetized with halothane in oxygen. Glomerular filtration rate (GFR) was measured simultaneously in each cat by exogenous creatinine clearance (ECC), bolus inulin clearance, and 99mTc(Sn)-diethylene-triaminepentaacetic acid (DTPA) clearance determined by 2 different methods. In the first DTPA clearance method (DTPA-1), we measured radioactivity in serial blood specimens to construct plasma disappearance curves for calculation of GFR. In the second DTPA clearance method (DTPA-2), we used serial external head counts of radioactivity and a single blood specimen to construct plasma disappearance curves for calculation of GFR. Bolus inulin clearance was calculated from plasma disappearance curves using a 1-compartment open pharmacokinetic model (IN-1) and a 2-compartment open pharmacokinetic model (IN-2). Glomerular filtration rates were measured over 3 hours, for creatinine and DTPA methods, and over 4 hours for the inulin methods. The GFR obtained with the reference method (ECC) was 2.56 +/- 0.61 ml/min/kg of body weight (mean +/- SD). Values for GFR determined by ECC and DTPA-1 were significantly correlated (r = 0.852; P less than or equal to 0.05). Correlation between ECC and DTPA 2 was not as good (r = 0.783; P less than or equal to 0.10), but the 2 DTPA methods significantly correlated with one another (r = 0.897; P less than or equal to 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
Glomerular filtration rate (GFR) was measured in 12 clinically normal horses, using the standard inulin clearance method, and values were compared with values for 2 methods, using a single rapid IV injection of 99mTc-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). The first 99mTc-DTPA method used a 2-compartment model to calculate GFR blood clearance of the tracer. The second method used sequential digital gamma camera images of the kidneys to determine fractional accumulation of the total dose of the tracer in the kidneys (percentage of injected dose, gamma camera) from 0 to 10 minutes after radionuclide administration. Linear correlation among the 3 methods was determined. Mean (+/- SD) GFR, using the inulin clearance method, was 154.67 +/- 42.28 ml/min/100 kg of body weight. Mean GFR, using the 2-compartment blood clearance curve, was 146.92 +/- 27.49 ml/min/100 kg. Mean GFR, using percentage of injected dose (gamma camera method) was 154.7 +/- 22.00 ml/min/100 kg. The percentage of injected dose (gamma camera method) did not correlate significantly to the inulin clearance results. However, a significant (r = 0.666, P less than 0.018) correlation was observed between the inulin method and the 99mTc-DTPA blood clearance method. Significant (P less than 0.0001) difference also was observed in the split function of the equine kidneys, with GFR of the right kidney contributing 60.1 +/- 9.12% of the total function, as determined by 99mTc-DTPA gamma camera imaging. Because the 99mTc-DTPA blood clearance method does not require urine collection, it may be a more practical procedure to measure GFR in the horse.  相似文献   

18.
BACKGROUND: Glomerular filtration rate (GFR) can be measured by clearance methods of different markers showing discrepancies and different reproducibility in healthy cats. Studies comparing different methods of GFR measurement in hyperthyroid cats have not yet been performed. HYPOTHESIS: Plasma clearance of exogenous creatinine (PECCT), exo-iohexol (PexICT), and endo-iohexol (PenICT) could lead to differences in GFR measurement and the need to use the same clearance method when comparing GFR before and after radioiodine treatment in hyperthyroid cats. ANIMALS: Fifteen client-owned hyperthyroid cats. METHODS: GFR was measured 1 day before and 1, 4, 12, and 24 weeks after treatment. Intravenous injection of iohexol was followed immediately by IV injection of creatinine. Plasma creatinine was measured by an enzymatic method. Plasma endo- and exo-iohexol were measured by high-performance liquid chromatography coupled to ultraviolet detection. RESULTS: Globally, the 3 GFR methods resulted in significantly different (P < .001) GFR results. GFR results among the different methods were the same (P= .999) at all time points. All 3 techniques indicated decreasing GFR after (131)I treatment. For each GFR technique, a significant decrease in GFR was observed between time point 0 and all other time points. This decrease stabilized 4 weeks after treatment, with very little decline afterward. CONCLUSION AND CLINICAL IMPORTANCE: It is mandatory to use the same GFR technique in follow-up studies. GFR testing at 4 weeks posttreatment could allow assessment of the final renal functional loss after treatment in hyperthyroid cats.  相似文献   

19.
The scintigraphically measured percentage dose uptake of 99mTc-DTPA by the kidneys and the plasma clearance of 99mTc-DTPA have been reported to correlate well with inulin clearance. These two parameters were evaluated in seven dogs with known or suspected naturally occurring renal disease and compared to simultaneously measured renal inulin clearance. Correlation between inulin clearance and the 99mTc-DTPA plasma clearance was better ( p =.0016) than the correlation between the percentage DTPA uptake by the kidney. It was concluded that measurement of 99mTc-DTPA plasma clearance is a more accurate method to estimate global glomerular filtration rate (GFR) than the percentage kidney uptake.  相似文献   

20.
BACKGROUND: Important characteristics determining the usefulness of a method for glomerular filtration rate (GFR) measurement are convenience, availability, and reproducibility. HYPOTHESIS: The use of different plasma clearance methods could lead to different results and differences in reproducibility. ANIMALS: Twelve healthy cats: 6 young adult cats (age 7-12 months), and 6 aged cats (age 9-12 years) were included in this study. METHODS: A cross-over design was used to compare the plasma clearance of exogenous creatinine (PECCT), exo-iohexol (PexICT), endo-iohexol (PenICT), and chromium-51 ethylenediaminetetraacetic acid (51Cr-EDTA), and to investigate reproducibility of these methods. Cats of different ages were included to determine if differences in GFR in young adult versus aged cats would be detected with these methods. The PECCT, PexICT, and PenICT were performed in a combined manner. Plasma data were subjected to noncompartmental (creatinine, exo-iohexol, and endo-iohexol) or bicompartmental (51Cr-EDTA) analysis with a statistical moment approach. Area under the concentration-time curve was calculated using the trapezoidal rule with extrapolation to infinity. Statistical analyses were carried out using a random effects model. RESULTS: Globally, the 4 methods differed significantly (P < .0001) in GFR assessment. Clearance of exo-iohexol and chromium-51 ethylenediaminetetraacetic acid (51Cr -EDTA) showed the highest and lowest reproducibility, respectively. Only plasma clearance of creatinine differed significantly between young adult and aged cats. CONCLUSION AND CLINICAL IMPORTANCE: We found considerable differences in reproducibility of different GFR measurements. These findings should be taken into account not only in practice but also in future studies involving GFR measurement.  相似文献   