首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polymerase chain reaction (PCR) methods have been the main technical support for the detection of genetically modified organisms (GMOs). To date, GMO-specific PCR detection strategies have been developed basically at four different levels, such as screening-, gene-, construct-, and event-specific detection methods. Event-specific PCR detection method is the primary trend in GMO detection because of its high specificity based on the flanking sequence of exogenous integrant. GM canola, event T45, with tolerance to glufosinate ammonium is one of the commercial genetically modified (GM) canola events approved in China. In this study, the 5'-integration junction sequence between host plant DNA and the integrated gene construct of T45 canola was cloned and revealed by means of TAIL-PCR. Specific PCR primers and TaqMan probes were designed based upon the revealed sequence, and qualitative and quantitative TaqMan real-time PCR detection assays employing these primers and probe were developed. In qualitative PCR, the limit of detection (LOD) was 0.1% for T45 canola in 100 ng of genomic DNA. The quantitative PCR assay showed limits of detection and quantification (LOD and LOQ) of 5 and 50 haploid genome copies, respectively. In addition, three mixed canola samples with known GM contents were detected employing the developed real-time PCR assay, and expected results were obtained. These results indicated that the developed event-specific PCR methods can be used for identification and quantification of T45 canola and its derivates.  相似文献   

2.
Because of the genetically modified organisms (GMOs) labeling policies issued in many countries and areas, polymerase chain reaction (PCR) methods were developed for the execution of GMO labeling policies, such as screening, gene specific, construct specific, and event specific PCR detection methods, which have become a mainstay of GMOs detection. The event specific PCR detection method is the primary trend in GMOs detection because of its high specificity based on the flanking sequence of the exogenous integrant. This genetically modified maize, MON863, contains a Cry3Bb1 coding sequence that produces a protein with enhanced insecticidal activity against the coleopteran pest, corn rootworm. In this study, the 5'-integration junction sequence between the host plant DNA and the integrated gene construct of the genetically modified maize MON863 was revealed by means of thermal asymmetric interlaced-PCR, and the specific PCR primers and TaqMan probe were designed based upon the revealed 5'-integration junction sequence; the conventional qualitative PCR and quantitative TaqMan real-time PCR detection methods employing these primers and probes were successfully developed. In conventional qualitative PCR assay, the limit of detection (LOD) was 0.1% for MON863 in 100 ng of maize genomic DNA for one reaction. In the quantitative TaqMan real-time PCR assay, the LOD and the limit of quantification were eight and 80 haploid genome copies, respectively. In addition, three mixed maize samples with known MON863 contents were detected using the established real-time PCR systems, and the ideal results indicated that the established event specific real-time PCR detection systems were reliable, sensitive, and accurate.  相似文献   

3.
For implementation of the issued regulations and labeling policies for genetically modified organism (GMO) supervision, the polymerase chain reaction (PCR) method has been widely used due to its high specificity and sensitivity. In particular, use of the event-specific PCR method based on the flanking sequence of transgenes has become the primary trend. In this study, both qualitative and quantitative PCR methods were established on the basis of the 5' flanking sequence of transgenic soybean A2704-12 and the 3' flanking sequence of transgenic soybean A5547-127, respectively. In qualitative PCR assays, the limits of detection (LODs) were 10 copies of haploid soybean genomic DNA for both A2704-12 and A5547-127. In quantitative real-time PCR assays, the LODs were 5 copies of haploid soybean genomic DNA for both A2704-12 and A5547-127, and the limits of quantification (LOQs) were 10 copies for both. Low bias and acceptable SD and RSD values were also achieved in quantification of four blind samples using the developed real-time PCR assays. In addition, the developed PCR assays for the two transgenic soybean events were used for routine analysis of soybean samples imported to Shanghai in a 6 month period from October 2010 to March 2011. A total of 27 lots of soybean from the United States and Argentina were analyzed: 8 lots from the Unites States were found to have the GM soybean A2704-12 event, and the GM contents were <1.5% in all eight analyzed lots. On the contrary, no GM soybean A5547-127 content was found in any of the eight lots. These results demonstrated that the established event-specific qualitative and quantitative PCR methods could be used effectively in routine identification and quantification of GM soybeans A2704-12 and A5547-127 and their derived products.  相似文献   

4.
To enforce the labeling regulations of genetically modified organisms (GMOs), the application of reference molecules as calibrators is becoming essential for practical quantification of GMOs. However, the reported reference molecules with tandem marker multiple targets have been proved not suitable for duplex PCR analysis. In this study, we developed one unique plasmid molecule based on one pMD-18T vector with three exogenous target DNA fragments of Roundup Ready soybean GTS 40-3-2 (RRS), that is, CaMV35S, NOS, and RRS event fragments, plus one fragment of soybean endogenous Lectin gene. This Lectin gene fragment was separated from the three exogenous target DNA fragments of RRS by inserting one 2.6 kb DNA fragment with no relatedness to RRS detection targets in this resultant plasmid. Then, we proved that this design allows the quantification of RRS using the three duplex real-time PCR assays targeting CaMV35S, NOS, and RRS events employing this reference molecule as the calibrator. In these duplex PCR assays, the limits of detection (LOD) and quantification (LOQ) were 10 and 50 copies, respectively. For the quantitative analysis of practical RRS samples, the results of accuracy and precision were similar to those of simplex PCR assays, for instance, the quantitative results were at the 1% level, the mean bias of the simplex and duplex PCR were 4.0% and 4.6%, respectively, and the statistic analysis ( t-test) showed that the quantitative data from duplex and simplex PCR had no significant discrepancy for each soybean sample. Obviously, duplex PCR analysis has the advantages of saving the costs of PCR reaction and reducing the experimental errors in simplex PCR testing. The strategy reported in the present study will be helpful for the development of new reference molecules suitable for duplex PCR quantitative assays of GMOs.  相似文献   

5.
As the genetically modified organisms (GMOs) labeling policies are issued in many countries, qualitative and quantitative polymerase chain reaction (PCR) techniques are increasingly used for the detection of genetically modified (GM) crops in foods. Qualitative PCR and TaqMan real-time quantitative PCR methods to detect and identify three varieties of insect resistant cotton, i.e., Mon531 cotton (Monsanto Co.) and GK19 and SGK321 cottons (Chinese Academy of Agricultural Sciences), which were approved for commercialization in China, were developed in this paper. Primer pairs specific to inserted DNAs, such as Cowpea trypsin inhibitor (CpTI) gene of SGK321 cotton and the specific junction DNA sequences containing partial Cry1A(c) gene and NOS terminator of Mon531, GK19, and SGK321 cotton varieties were designed to conduct the identified PCR assays. In conventional specific identified PCR assays, the limit of detection (LOD) was 0.05% for Mon531, GK19, or SGK321 in 100 ng of cotton genomic DNA for one reaction. Also, the multiplex PCR method for screening the three GM cottons was also established, which could save time and cost in practical detection. Furthermore, a real-time quantitative PCR assay based on TaqMan chemistry for detection of insect resistant gene, Cry1A(c), was developed. This assay also featured the use of a standard plasmid as a reference molecule, which contained both a specific region of the transgene Cry1A(c) and an endogenous stearoyl-acyl carrier protein desaturase (Sad1) gene of the cotton. In quantitative PCR assay, the quantification range was from 0.01 to 100% in 100 ng of the genome DNA template, and in the detection of 1.0, 3.0, and 5.0% levels of three insect resistant cotton lines, respectively, all of the relative standard deviations (RSDs) were less than 8.2% except for the GM cotton samples with 1.0% Mon531 or GK19, which meant that our real-time PCR assays involving the use of reference molecule were reliable and practical for GM insect resistant cottons quantification. All of these results indicated that our established conventional and TaqMan real-time PCR assays were applicable to detect the three insect resistant cottons qualitatively and quantitatively.  相似文献   

6.
Except for the events RT73, MS8, RF3, and T45, event-specific detection methods for most commercialized genetically modified (GM) rapeseed varieties have not been established, and as a result, the enforcement of genetically modified organism labeling policies has been hindered. The genetically modified rapeseeds, MS1xRF1 and MS1xRF2, are 2 of 11 approved GM-rapeseed varieties for commercialization. In this study, the right border junction fragments between the gene construct and the rapeseed genome of events RF1, RF2, and MS1 were isolated using the commercially available GenomeWalker technology. Homology analysis indicated that the gene construct of RF1 integrated upstream of the nuclease gene, and that of the RF2 and MS1 inserted into the exon region of a gene encoding for an unknown protein. The event-specific primer pairs and corresponding probes were designed on the basis of the revealed right border junction fragments. Then, we successfully developed the identification and quantification methods for the gene-stacked hybrids MS1xRF1 and MS1xRF2 using those primers and probes. The relative limit of detection in the qualitative polymerase chain reaction (PCR) was 0.013% for the RF2 and MS1 assays using 100 ng of rapeseed DNA per reaction and 0.13% for the RF1 assay. The absolute limit of detection in the quantitative PCR was approximately one to two initial copies for each of the three event-specific assays. The evaluation of the real-time PCR assays revealed that the qualitative and quantitative methods developed by focusing on the gene-stacked hybrids MS1xRF1 and MS1xRF2 were highly specific, sensitive, and suitable for samples with a low quantity of DNA.  相似文献   

7.
Several countries have introduced mandatory labeling requirements on foods derived from genetically modified organisms. Real-time quantitative Polymerase Chain Reaction (PCR) has quickly become the method of choice in support of these regulations and requires the development of separate PCR assays targeting the transgenic sequence as well as a specific endogenous gene sequence. To develop a Brassica napus-specific PCR assay, partial sequences of the acetyl-CoA carboxylase BnACCg8 gene from B. napus and the closely related Brassica rapa were determined and compared, and a region of unique nucleotide sequence was identified. Universal amplification primers were designed to either side of this region, and a locked nucleic acid TaqMan probe was designed to the B. napus-specific sequence. Evaluation of this primer/probe combination indicated a high level of specificity to B. napus: no amplification signal was observed with any other species tested, including five closely related Brassica species. The method was assayed with 14 different B. napus cultivars, and comparable amplification curves were consistently obtained for all. The assay was highly sensitive, with a limit of detection between 1 and 10 haploid copies. Practically, the method was demonstrated to be effective for the detection of processed food samples and for the quantification of Roundup Ready canola content in mixed samples.  相似文献   

8.
The most widely accepted methods for accurate quantitative detection of genetically modified organisms rely on real-time PCR. Various detection chemistries are available for real-time PCR. They include sequence-unspecific DNA labeling dyes such SYBR-Green I and the use of both universal (e.g., AmpliFluor) and sequence-specific double-labeled probes, the latter comprising hybridization (e.g., Molecular Beacon) and hydrolysis (e.g., TaqMan or MGB) probes. Also, new real-time PCR devices and reagents allowing fast cycling reactions exist. Five Mon810 real-time PCR assays were developed in which the event specificity was based on the detection of transgene and plant rearranged sequences found to 3' flank the insertion site. Every assay was specifically designed for one particular detection chemistry, that is, AmpliFluor, Molecular Beacon, MGB, TaqMan, and SYBR-Green I. When possible, the assays were adapted to fast cycling mode. All assays displayed satisfactory performance parameters, although Molecular Beacon, MGB, and TaqMan chemistries were the most suitable for quantification purposes in both conventional and fast cycling modes.  相似文献   

9.
Many countries have introduced mandatory labeling requirements on foods derived from genetically modified organisms (GMOs). Real-time quantitative polymerase chain reaction (PCR) based upon the TaqMan probe chemistry has become the method mostly used to support these regulations; moreover, event-specific PCR is the preferred method in GMO detection because of its high specificity based on the flanking sequence of the exogenous integrant. The aim of this study was to evaluate the use of very short (eight-nucleotide long), locked nucleic acid (LNA) TaqMan probes in 5'-nuclease PCR assays for the detection and quantification of GMOs. Classic TaqMan and LNA TaqMan probes were compared for the analysis of the maize MON810 transgene. The performance of the two types of probes was tested on the maize endogenous reference gene hmga, the CaMV 35S promoter, and the hsp70/cryIA(b) construct as well as for the event-specific 5'-integration junction of MON810, using plasmids as standard reference molecules. The results of our study demonstrate that the LNA 5'-nuclease PCR assays represent a valid and reliable analytical system for the detection and quantification of transgenes. Application of very short LNA TaqMan probes to GMO quantification can simplify the design of 5'-nuclease assays.  相似文献   

10.
We have tested and compared the performance of 12 different assays representing four different real-time polymerase chain reaction (PCR) chemistries in the context of genetically modified organism detection. Several different molecular beacon, SYBR Green, TaqMan, and MGB assays were designed for the event specific detection and quantification of the 3' integration junction of GTS 40-3-2 (Roundup Ready) soybean. Sensitivity as well as robustness in the presence of background DNA were tested. None of the PCR-based approaches appeared to be significantly better than any of the other, but the molecular beacon assays had the lowest efficiency and also seemed more sensitive to changes in experimental setup.  相似文献   

11.
Polymerase chain reaction (PCR) methods are very useful techniques for the detection and quantification of genetically modified organisms (GMOs) in food samples. These methods rely on the amplification of transgenic sequences and quantification of the transgenic DNA by comparison to an amplified reference gene. Reported here is the development of specific primers for the rapeseed (Brassica napus) BnACCg8 gene and PCR cycling conditions suitable for the use of this sequence as an endogenous reference gene in both qualitative and quantitative PCR assays. Both methods were assayed with 20 different rapeseed varieties, and identical amplification products were obtained with all of them. No amplification products were observed when DNA samples from other Brassica species, Arabidopsis thaliana, maize, and soybean were used as templates, which demonstrates that this system is specific for rapeseed. In real-time quantitative PCR analysis, the detection limit was as low as 1.25 pg of DNA, which indicates that this method is suitable for use in processed food samples which contain very low copies of target DNA.  相似文献   

12.
To enforce the labeling regulations of genetically modified organisms (GMOs), the application of DNA plasmids as calibrants is becoming essential for the practical quantification of GMOs. This study reports the construction of plasmid pTC1507 for a quantification assay of genetically modified (GM) maize TC1507 and the collaborative ring trial in international validation of its applicability as a plasmid calibrant. pTC1507 includes one event-specific sequence of TC1507 maize and one unique sequence of maize endogenous gene zSSIIb. A total of eight GMO detection laboratories worldwide were invited to join the validation process, and test results were returned from all eight participants. Statistical analysis of the returned results showed that real-time PCR assays using pTC1507 as calibrant in both GM event-specific and endogenous gene quantifications had high PCR efficiency (ranging from 0.80 to 1.15) and good linearity (ranging from 0.9921 to 0.9998). In a quantification assay of five blind samples, the bias between the test values and true values ranged from 2.6 to 24.9%. All results indicated that the developed pTC1507 plasmid is applicable for the quantitative analysis of TC1507 maize and can be used as a suitable substitute for dried powder certified reference materials (CRMs).  相似文献   

13.
The genetically modified (GM) food/feed quantification depends on the reliable detection systems of endogenous reference genes. Currently, four endogenous reference genes including sucrose phosphate synthase (SPS), GOS9, phospholipase D (PLD), and ppi phosphofructokinase (ppi-PPF) of rice have been used in GM rice detection. To compare the applicability of these four rice reference genes in quantitative PCR systems, we analyzed the target nucleotide sequence variation in 58 conventional rice varieties from various geographic and phylogenic origins, also their quantification performances were evaluated using quantitative real-time PCR and GeNorm analysis via a series of statistical calculation to get a "M value" which is negative correlation with the stability of genes. The sequencing analysis results showed that the reported GOS9 and PLD taqman probe regions had detectable single nucleotide polymorphisms (SNPs) among the tested rice cultivars, while no SNPs were observed for SPS and ppi-PPF amplicons. Also, poor quantitative performance was detectable in these cultivars with SNPs using GOS9 and PLD quantitative PCR systems. Even though the PCR efficiency of ppi-PPF system was slightly lower, the SPS and ppi-PPF quantitative PCR systems were shown to be applicable for rice endogenous reference assay with less variation among the C(t) values, good reproducibility in quantitative assays, and the low M values by the comprehensive quantitative PCR comparison and GeNorm analysis.  相似文献   

14.
A genetic marker system based on the S1 Short Interspersed Elements (SINEs) in the important commercial crop, oilseed rape ( Brassica napus L.) has been developed. SINEs provided a successful multilocus, dominant marker system that was capable of clearly delineating winter- and spring-type crop varieties. Sixteen of 20 varieties tested showed unique profiles from the 17 polymorphic SINE markers generated. The 3' or 5' flank region of nine SINE markers were cloned, and DNA was sequenced. In addition, one putative pre-transposition SINE allele was cloned and sequenced. Two SINE flanking sequences were used to design real-time PCR assays. These quantitative SINE assays were applied to study the genetic structure of eight fields of oilseed rape crops. Studied fields were more genetically diverse than expected for the chosen loci (mean H T = 0.23). The spatial distribution of SINE marker frequencies was highly structured in some fields, suggesting locations of volunteer impurities within the crop. In one case, the assay identified a mislabeling of the crop variety. SINE markers were a useful tool for crop genetics, phylogenetics, variety identification, and purity analysis. The use and further application of quantitative, real-time PCR markers are discussed.  相似文献   

15.
Multiplex PCR procedures were developed for simultaneously detecting multiple target sequences in genetically modified (GM) soybean (Roundup Ready), maize (event 176, Bt11, Mon810, T14/25), and canola (GT73, HCN92/28, MS8/RF3, Oxy 235). Internal control targets (invertase gene in corn, lectin and beta-actin genes in soybean, and cruciferin gene in canola) were included as appropriate to assess the efficiency of all reactions, thereby eliminating any false negatives. Primer combinations that allowed the identification of specific lines were used. In one system of identification, simultaneous amplification profiling (SAP), rather than target specific detection, was used for the identification of four GM maize lines. SAP is simple and has the potential to identify both approved and nonapproved GM lines. The template concentration was identified as a critical factor affecting efficient multiplex PCRs. In canola, 75 ng of DNA template was more effective than 50 ng of DNA for the simultaneous amplification of all targets in a reaction volume of 25 microL. Reliable identification of GM canola was achieved at a DNA concentration of 3 ng/microL, and at 0.1% for GM soybean, indicating high levels of sensitivity. Nonspecific amplification was utilized in this study as a tool for specific and reliable identification of one line of GM maize. The primer cry1A 4-3' (antisense primer) recognizes two sites on the DNA template extracted from GM transgenic maize containing event 176 (European corn borer resistant), resulting in the amplification of products of 152 bp (expected) and 485 bp (unexpected). The latter fragment was sequenced and confirmed to be Cry1A specific. The systems described herein represent simple, accurate, and sensitive GMO detection methods in which only one reaction is necessary to detect multiple GM target sequences that can be reliably used for the identification of specific lines of GMOs.  相似文献   

16.
Qualitative and quantitative Polymerase Chain Reaction (PCR) systems aimed at the specific detection and quantification of common wheat DNA are described. Many countries have issued regulations to label foods that include genetically modified organisms (GMOs). PCR technology is widely recognized as a reliable and useful technique for the qualitative and quantitative detection of GMOs. Detection methods are needed to amplify a target GM gene, and the amplified results should be compared with those of the corresponding taxon-specific reference gene to obtain reliable results. This paper describes the development of a specific DNA sequence in the waxy-D1 gene for common wheat (Triticum aestivum L.) and the design of a specific primer pair and TaqMan probe on the waxy-D1 gene for PCR analysis. The primers amplified a product (Wx012) of 102 bp. It is indicated that the Wx012 DNA sequence is specific to common wheat, showing homogeneity in qualitative PCR results and very similar quantification accuracy along 19 distantly related common wheat varieties. In Southern blot and real-time PCR analyses, this sequence showed either a single or a low number of copy genes. In addition, by qualitative and quantitative PCR using wx012 primers and a wx012-T probe, the limits of detection of the common wheat genome were found to be about 15 copies, and the reproducibility was reliable. In consequence, the PCR system using wx012 primers and wx012-T probe is considered to be suitable for use as a common wheat-specific taxon-specific reference gene in DNA analyses, including GMO tests.  相似文献   

17.
A simple and reproducible method for qualitative and quantitative analysis of phenolic compounds in virgin olive oils by solid-phase extraction (SPE), high performance liquid chromatography with diode array detector (HPLC-DAD), and HPLC-mass spectrometry (MS) in tandem mode was developed. The polar fraction was obtained from samples of three different virgin olive oils. Detection and quantification were performed at 280, 240, and 320 nm. For identification purposes, HPLC-MS/MS was equipped with turbo ion spray source in the negative-ion mode. Twenty compounds of twenty-three detected and quantified were characterized. The method showed satisfactory linearity (r > 0.99), good recovery, satisfactory precision, and appropriate limits of detection (LOD) and quantification (LOQ).  相似文献   

18.
The number of cultured hectares and commercialized genetically modified organisms (GMOs) has increased exponentially in the past 9 years. Governments in many countries have established a policy of labeling all food and feed containing or produced by GMOs. Consequently, versatile, laboratory-transferable GMO detection methods are in increasing demand. Here, we describe a qualitative PCR-based multiplex method for simultaneous detection and identification of four genetically modified maize lines: Bt11, MON810, T25, and GA21. The described system is based on the use of five primers directed to specific sequences in these insertion events. Primers were used in a single optimized multiplex PCR reaction, and sequences of the amplified fragments are reported. The assay allows amplification of the MON810 event from the 35S promoter to the hsp intron yielding a 468 bp amplicon. Amplification of the Bt11 and T25 events from the 35S promoter to the PAT gene yielded two different amplicons of 280 and 177 bp, respectively, whereas amplification of the 5' flanking region of the GA21 gave rise to an amplicon of 72 bp. These fragments are clearly distinguishable in agarose gels and have been reproduced successfully in a different laboratory. Hence, the proposed method comprises a rapid, simple, reliable, and sensitive (down to 0.05%) PCR-based assay, suitable for detection of these four GM maize lines in a single reaction.  相似文献   

19.
Protein-based detection methods, enzyme-linked immunosorbent assay (ELISA) and lateral flow strip, have been widely used for rapid, spot, and sensitive detection of genetically modified organisms (GMOs). Herein, one novel quantum dot-based fluorescence-linked immunosorbent assay (QD-FLISA) was developed employing quantum dots (QDs) as the fluorescent marker for the detection of the Cry1Ab protein in MON810 maize. The end-point fluorescent detection system was carried out using QDs conjugated with goat anti-rabbit secondary antibody. The newly developed Cry1Ab QD-FLISA assay was highly specific to the Cry1Ab protein and had no cross-reactivity with other target proteins, such as Cry2Ab, Cry1F, and Cry3Bb. The quantified linearity was achieved in the value range of 0.05-5% (w/w). The limits of detection (LOD) and quantification (LOQ) of the QD-FLISA were 2.956 and 9.854 pg/mL, respectively, which were more sensitive than the conventional sandwich ELISA method. All of the results indicated that QD-FLISA was a highly specific and sensitive method for the monitoring of Cry1Ab in GMOs.  相似文献   

20.
Using a statistical approach, sampling plans for the semiquantitative detection of genetically modified (GM) canola within a bulk seed sample can be developed and tailored to meet different GM thresholds, costs, and confidence limits. This is achieved by changing the number of subsamples analyzed, the number of seeds per subsample, and the percentage of positive results allowed. These sampling plans must be devised carefully, taking into account the detection capability of the analytical assay. This is particularly important in the case of InVigor (a registered trademark of Bayer CropScience) canola, for which expression levels of the introduced protein in seed are very low. Lateral flow assays and enzyme-linked immunosorbent assays (ELISA) were both investigated for their suitability as a qualitative assay using a subsampling approach. On the basis of an ELISA, several sampling plans have been devised and validated to provide at least 99% confidence that bulk seed samples containing at least 0.9% (w/w) InVigor canola will be detected. Although the term "seed" is used throughout this paper to refer to the canola, the term "seed" is to be taken to include both seed and the canola seed (grain) that is harvested by the farmer/grower.  相似文献   