 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract: Aggregation of feline platelets in vitro results in difficulty assessing platelet number. A citrate-based anticoagulant containing the platelet inhibitors theophylline, adenosine, and dipyridamole (CTAD; Diatube-H, Becton Dickinson, Oxford, UK) has been developed for use in human platelet studies and heparin assays. To evaluate the efficacy of CTAD in reducing platelet aggregation in feline blood samples, aliquots of blood from 51 cats were anticoagulated with EDTA, CTAD, and for 12 samples, citrate solution. Samples preserved in CTAD had significantly higher (P ≤ .001) platelet counts, as determined by an impedance counter, hemacy-tometer, and smear estimation, than samples preserved in EDTA. In addition, subjective assessment of blood smears showed significantly fewer platelet aggregates (P<.001) in CTAD-treated samples compared with EDTA samples. Although values were similar, automated platelet counts and smear estimates of platelet number were significantly higher (P < .05) and platelet aggregation was significantly less (P < .05) in CTAD samples than in citrate samples. These results suggest that the platelet inhibitory activity of CTAD reduced feline platelet aggregation. Automated total WBC counts in CTAD samples were significantly lower (P<.001) than automated counts in EDTA samples but were similar to manual WBC counts in EDTA samples. Differences in both platelet and WBC counts between CTAD and EDTA or citrate samples were clinically relevant. Mean platelet volume and MCV were significantly lower (P< .05) in CTAD samples than in EDTA samples. No effect was seen on cell morphology or staining characteristics. The anticoagulant CTAD offers an advantage over both EDTA and citrate for feline hematologic analysis, by decreasing pseudothrombocytopenia and pseudoleukocytosis.  相似文献   

2.
Background: The CBC is an essential test for assessing the health of rats used in drug development studies. Because of limited blood volume, estimates of cell counts from a blood smear would be valuable when other analytical methods of enumerating cells are not possible or available. Objective: The purpose of this study was to develop a statistical model to accurately estimate WBC, platelet (PLT), and RBC counts in blood smears from rats. Method: Blood smears and quantitative cell counts were obtained from vehicle‐treated male and female Fischer 344 rats (n=65) involved in a variety of studies. The numbers of WBCs, PLTs, and RBCs were estimated in 10 fields in the monolayer of smears using × 20 (WBC) or × 100 (PLT, RBC) objectives. Using a statistical model and the quantitative cell counts obtained on an ADVIA 120 hematology analyzer, formulas were developed to predict the quantitative counts from the estimates. Results: Data were log‐transformed before analysis. A formula was derived using the slope and intercept of the regression line between cell estimates and ADVIA counts to predict WBC, PLT, and RBC counts based only on estimates. A second formula was developed for situations in which limited quantitative analyses may be available, and resulted in even more accurately predicted counts from smear estimates. Conclusion: The formulas developed in this study can be a valuable tool in estimating cell counts from a blood smear when cell counting instruments are not available or when an instrument cell count needs to be verified. These formulas may be useful in the assessment of rat blood in discovery and lead optimization studies.  相似文献   

3.
BACKGROUND: The ADVIA 120 is an automated laser cell counter widely used in veterinary medicine. Although specific software for equine samples is available and validated, only a few reports have been published comparing the ADVIA 120 with other methods for equine hemogram evaluation. OBJECTIVES: The purpose of this study was to compare the hematologic values and reference intervals obtained on the ADVIA 120 with those obtained on an impedance cell counter and manual differential counts in healthy horses. METHODS: EDTA-anticoagulated blood samples were obtained from 114 clinically healthy horses of various breeds, both sexes, and 2-6 years of age. Samples were stored for up to 12 hours at 4 degrees C and then analyzed on the ADVIA 120 and the Hemat 8. A 100-cell to 200-cell differential leukocyte count was performed by 3 independent observers on May-Grünwald-Giemsa-stained smears. Intra-assay precision of the ADVIA 120 was determined by analyzing 5 replicates each of 10 of the blood samples. RESULTS: Results from the ADVIA were significantly higher than those from the impedance counter for RBC count, total WBC count, hemoglobin concentration, red cell distribution width, MCH, and MCHC, and significantly lower for HCT and platelet count. Significantly higher neutrophil and basophil counts and significantly lower lymphocyte counts were obtained with the ADVIA 120 compared with manual counts. Based on Passing-Bablok regression analysis, RBC and platelet counts were in good agreement between the 2 analyzers; a constant and proportional bias was present for other values. Coefficients of variation for erythrocyte parameters on the ADVIA were <1%, but were higher for platelet (6%), total WBC (2%), differential WBC (4%-30%), and reticulocyte (75%) counts. CONCLUSIONS: Results obtained with equine samples on the ADVIA 120 were comparable with those obtained on an impedance counter; reference intervals differed statistically but overlapped. The ADVIA had poor precision for reticulocyte and differential leukocyte counts such that the latter should always be verified on smears.  相似文献   

4.
Abstract: True thrombocytopenia is uncommon in cats; however, low platelet counts frequently are found using automated cell counters. Although this discrepancy is a well known problem, the prevalence of low automated platelet counts in feline blood samples has not been documented. We retrospectively compared the prevalence of low automated platelet counts with low blood smear-estimated platelet counts in feline blood samples. Results of blood sample analysis from 359 cats during a 1-year period at the University of Glasgow Veterinary Haematology Laboratory were examined. Smear estimates of platelet number were done in those cases in which records did not indicate adequate platelet numbers. Platelet counts obtained with an impedance counter (Minos Vet, Abx Hematologie) were <200×109 cells/L in 256 samples (71%) and <50×109 cells/L in 43 samples (12%). However, based on estimation of platelet numbers from blood smears, only 11 samples (3.1%) had platelet counts of <200×109 cells/L and 9 samples (2.5%) had counts of <50×109 cells/L. Four cats with thrombocytopenia estimated by blood smear evaluation had clinical signs of a bleeding disorder. Disorders associated with thrombocytopenia included neoplasia, cytotoxic chemotherapy, and infectious diseases. There was no evidence that delay due to mailing of samples was associated with lower automated platelet counts than would have been obtained on the day of sampling. The high prevalence of apparent thrombocytopenia in automated platelet counts was attributed to a combination of platelet aggregation and the impedance method of cell differentiation by size. Vigilance and careful examination of blood smears is required to identify the few cats with true thrombocytopenia.  相似文献   

5.
Background: A CBC is an integral part of the assessment of health and disease in companion animals. While in the past newer technologies for CBC analysis were limited to large clinical pathology laboratories, several smaller and affordable automated hematology analyzers have been developed for in‐clinic use. Objectives: The purpose of this study was to compare CBC results generated by 7 in‐clinic laser‐ and impedance‐based hematology instruments and 2 commercial laboratory analyzers. Methods: Over a 3‐month period, fresh EDTA‐anticoagulated blood samples from healthy and diseased dogs (n=260) and cats (n=110) were analyzed on the LaserCyte, ForCyte, MS45, Heska CBC, Scil Vet ABC, VetScan HMT, QBC Vet Autoread, CELL‐DYN 3500, and ADVIA 120 analyzers. Results were compared by regression correlation (linear, Deming, Passing‐Bablok) and Bland–Altman bias plots using the ADVIA as the criterion standard for all analytes except HCT, which was compared with manual PCV. Precision, linearity, and carryover also were evaluated. Results: For most analytes, the in‐clinic analyzers and the CELL‐DYN performed similarly and correlated well with the ADVIA. The biases ranged from ?0.6 to 2.4 × 109/L for WBC count, 0 to 0.9 × 1012/L for RBC count, ?1.5 to 0.7 g/dL for hemoglobin concentration, ?4.3 to 8.3 fL for MCV, and ?69.3 to 77.2 × 109/L for platelet count. Compared with PCV, the HCT on most analyzers had a bias from 0.1% to 7.2%. Canine reticulocyte counts on the LaserCyte and ForCyte correlated but had a negative bias compared with those on the ADVIA. Precision, linearity, and carryover results were excellent for most analyzers. Conclusions: Total WBC and RBC counts were acceptable on all in‐clinic hematology instruments studied, with limitations for some RBC parameters and platelet counts. Together with evaluation of a blood film, these in‐clinic instruments can provide useful information on canine and feline patients in veterinary practices.  相似文献   

6.
BACKGROUND: Computer-aided instruction (CAI) was developed to teach veterinary students how to make blood smears. This instruction was intended to replace the traditional instructional method in order to promote efficient use of faculty resources while maintaining learning outcomes and student satisfaction. OBJECTIVES: The purpose of this study was to evaluate the effect of a computer-aided blood smear tutorial on 1) instructor's teaching time, 2) students' ability to make blood smears, and 3) students' ability to recognize smear quality. METHODS: Three laboratory sessions for senior veterinary students were taught using traditional methods (control group) and 4 sessions were taught using the CAI tutorial (experimental group). Students in the control group received a short demonstration and lecture by the instructor at the beginning of the laboratory and then practiced making blood smears. Students in the experimental group received their instruction through the self-paced, multimedia tutorial on a laptop computer and then practiced making blood smears. Data was collected from observation, interview, survey questionnaires, and smear evaluation by students and experts using a scoring rubric. RESULTS: Students using the CAI made better smears and were better able to recognize smear quality. The average time the instructor spent in the room was not significantly different between groups, but the quality of the instructor time was improved with the experimental instruction. CONCLUSIONS: The tutorial implementation effectively provided students and instructors with a teaching and learning experience superior to the traditional method of instruction. Using CAI is a viable method of teaching students to make blood smears.  相似文献   

7.
Platelet counts were performed in 50 cats presented for diagnostic investigation. For each cat, counts were obtained using a manual haemocytometer method and compared with counts obtained by estimation from a stained blood smear, a QBC VetAutoread analyser, a Zynocyte VS/2000 analyser, impedance automated counts on a Baker System using both EDTA and citrated anticoagulated blood, and use of a Zynostain modified counting chamber kit. None of the methods gave high correlation with the haemocytometer counts. The blood smear estimation of platelet counts had the highest correlation (r = 0.776) and was the only method to have reasonable values for both sensitivity and specificity. With the impedance automated counts, citrated anticoagulated blood had marginally higher correlation than EDTA anticoagulated blood, and the time between blood sampling and platelet count determination had no effect on the count obtained. When in-house analyser or impedance automated platelet counts are abnormal or not consistent with clinical findings, the authors recommend that a manual platelet count using either haemocytometry or examination of a blood smear is performed.  相似文献   

8.
Background: With more use of bench‐top in‐office hematology analyzers, the accuracy of reported values is increasingly important. Instruments use varied methods for cell counting and differentiation, and blood smears may not always be examined. Objective: The purpose of this study was to compare canine CBC results using 4 bench‐top instruments (Hemavet 950, Heska CBC‐Diff, IDEXX LaserCyte, and IDEXX VetAutoread) with ADVIA 120 and manual leukocyte counts. Methods: EDTA‐anticoagulated canine blood samples (n=100) were analyzed on each instrument. Manual differentials were based on 100‐cell counts. Linear regression, difference plots, paired t‐tests, and estimation of diagnostic equivalence were used to analyze results. Results: Correlations of HCT, WBC, and platelet counts were very good to excellent between all in‐office instruments and the ADVIA 120, but results varied in accuracy (comparability). Hemavet 950 and Heska CBC‐Diff results compared best with ADVIA results and manual leukocyte differentials. HCT and platelet counts on the IDEXX VetAutoread compared well with those from the ADVIA. Except for neutrophil counts, leukocyte differentials from all instruments compared poorly with ADVIA and manual counts. Reticulocyte counts on the LaserCyte and VetAutoread compared poorly with those from the ADVIA. Conclusions: The Hemavet 950 and Heska CBC‐Diff performed best of the 4 analyzers we compared. HCT, WBC, and platelet counts on the LaserCyte had minimally sufficient comparability for diagnostic use. Except for neutrophils (granulocytes), leukocyte differential counts were unreliable on all in‐office analyzers. Instruments with a 5‐part leukocyte differential provided no added benefit over a 3‐part differential. Assessment of erythrocyte regeneration on the LaserCyte and VetAutoread was unreliable compared with the ADVIA 120.  相似文献   

9.
A blood sample from a 14‐year‐old dog was submitted to the veterinary diagnostic laboratory of the University of Milan for marked leukocytosis with atypical cells. A diagnosis of chronic T‐cell lymphocytic leukemia (CLL) was made based on blood smear evaluation and flow cytometric phenotyping. A CBC by Sysmex XT‐2000iV revealed a moderate normocytic normochromic anemia. Red blood cells counted by optic flow cytometry (RBC‐O) resulted in a higher value than using electrical impedance (RBC‐I). The relative reticulocyte count based on RNA content and size was 35.3%, while the manual reticulocyte count was < 1%. The WBC count of 1,562,680 cells/μL was accompanied by a flag. Manual counts for RBC and WBC using the Bürker chamber confirmed the Sysmex impedance results. Finally the manual PCV was lower than HCT by Sysmex. While Sysmex XT can differentiate between RBC and WBC by impedance, even in the face of extreme lymphocytosis due to CLL, RBC‐O can be affected by bias, resulting in falsely increased RBC and reticulocyte numbers. Overestimation of RBC‐O may be due to incorrect Sysmex classification of leukemic cells or their fragments as reticulocytes. This phenomenon is known as pseudoreticulocytosis and can lead to misinterpretation of regenerative anemia. On the other side PCV can be affected by bias in CLL due to the trapping of RBC in the buffy coat, resulting in a pink hue in the separation area. As HGB concentration is not affected by flow cytometric or other cell‐related artifacts it may represent the most reliable variable to assess the degree of anemia in cases of CLL.  相似文献   

10.
Blood samples were obtained from 50 cats admitted for hematologic evaluation at the Royal (Dick) School of Veterinary Studies. Manual platelet counts were done using a hemacytometer, and the average number of platelets per oil immersion field (1,000X magnification) was determined on stained blood smears. A hemacytometer count was not obtained for one sample because of a failure in erythrocyte lysing. In nine samples, obvious platelet clumps in the blood smear prevented accurate determination of the number of platelets per oil immersion field. Hemacytometer counts on these nine samples ranged from 260-587 X 10 (3) platelets/microliter, suggesting that platelet clumps on a blood smear were usually associated with adequate platelet numbers. Simple regression analysis of hemacytometer counts and the average umber of platelets per oil immersion field for the remaining 40 samples yielded correlation coefficients (r) of 0.776 on untransformed data, and 0.892 on log10-transformed data. Each platelet per oil immersion field represented a circulating platelet count of approximately 20 X 10(3)/microliter, similar to conversion factors reported for dogs and human beings. It was concluded that estimation of platelet number on stained blood smears is a simple and quick method that appears to be reliable over a wide range of platelet counts in cats.  相似文献   

11.
Background: The Sysmex XT‐2000iV is a laser‐based, flow cytometric hematology system that has been introduced for use in large and referral veterinary laboratories. Objective: The purpose of this study was to validate the Sysmex XT‐2000iV for counting erythrocytes, reticulocytes, platelets, and total leukocytes in blood from ill dogs, cats, and horses. Methods: Blood samples from diseased animals (133 dogs, 65 cats, and 73 horses) were analyzed with the Sysmex XT‐2000iV and the CELL‐DYN 3500. Manual reticulocyte counts were done on an additional 98 canine and 14 feline samples and manual platelet counts were done on an additional 73 feline and 55 canine samples, and compared with automated Sysmex results. Results: Hemoglobin concentration, RBC counts, and total WBC counts on the Sysmex were highly correlated with those from the CELL‐DYN (r≥0.98). Systematic differences occurred for MCV and HCT. MCHC was poorly correlated in all species (r=0.33–0.67). The Sysmex impedance platelet count in dogs was highly correlated with both the impedance count from the CELL‐DYN (r=0.99) and the optical platelet count from the Sysmex (r=0.98). The Sysmex optical platelet count included large platelets, such that in samples from cats, the results agreed better with manual platelet counts than with impedance platelet counts on the Sysmex. Canine reticulocyte counts on the Sysmex correlated well (r=0.90) with manual reticulocyte counts. Feline reticulocyte counts on the Sysmex correlated well with aggregate (r=0.86) but not punctate (r=0.50) reticulocyte counts. Conclusion: The Sysmex XT‐2000iV performed as well as the CELL‐DYN on blood samples from dogs, cats, and horses with a variety of hematologic abnormalities. In addition, the Sysmex detected large platelets and provided accurate reticulocyte counts.  相似文献   

12.
An 8‐year‐old, male Rhesus macaque (Macaca mulatta), previously used for dengue virus (DENV) vaccine research with viral challenge, was presented with adult‐onset, chronic, cyclic thrombocytopenia. Platelet number, morphology, and function were evaluated by automated hematology, peripheral blood smears, electron microscopy, flow cytometry, and impedance aggregometry. Bone marrow was evaluated by cytology. Both serum anti‐dengue nonstructural protein 1 (NS1) antibodies and anti‐platelet antibodies were detected by ELISA. Platelet characterization showed a lack of aggregation to all agonists (ADP, ASP, and collagen), increased activation with increased expression of surface marker (HLA‐ABC), and an absence of surface receptor GPIX during clinical episodes of petechiae and ecchymoses, even in the presence of normal platelet counts. Bone marrow aspirates identified potential mild megakaryocytic hypoplasia. All platelet functions and morphologic attributes were within normal limits during clinically normal phases. Presence of anti‐dengue NS1 serum antibodies confirmed a positive DENV titer 8 years postvaccination. Based on the history and clinical findings, a primary differential diagnosis for this chronic, cyclic platelet pathology was autoimmune platelet destruction with potential bone marrow involvement.  相似文献   

13.
Background: Glucose assessment and regulation are important factors in the treatment of hospitalized horses and foals. Hypothesis/Objectives: The purpose of this study was to compare glucose measurement by a veterinary glucometer, adjusted by code for use in horses and foals, to a reference chemistry analyzer. It was hypothesized that the veterinary glucometer and reference analyzer would yield similar results and that interpretation of glucose values obtained from a veterinary glucometer would result in clinically appropriate decisions. Animals: Fifty blood samples from adult horses and 50 blood samples from neonatal foals admitted to the Colorado State University Veterinary Hospital or Equine Reproduction Laboratory for evaluation. Methods: Glucose concentrations from fresh whole blood samples were evaluated in duplicate with a veterinary glucometer and these values were compared with those obtained with a reference plasma chemistry analyzer. The accuracy of glucometer measurement was evaluated with a Clarke error grid. Results: The veterinary glucometer accurately measured whole blood glucose concentrations in both horses and foals when compared with a reference plasma chemistry analyzer. Nearly 97% of the glucometer values obtained in this study would have resulted in appropriate clinical decisions based on the Clarke error grid analysis. Conclusions and Clinical Importance: The veterinary glucometer evaluated has potential utility for point‐of‐care whole blood glucose evaluation in both horses and foals.  相似文献   

14.
Abstract: Platelet clumping is a common cause of erroneous platelet counts in cats. Mixing of blood with a vortex mixer was evaluated as a method to disaggregate platelet clumps in feline blood and thus obtain accurate platelet counts. Whole blood samples from 42 cats with platelet clumping and 10 control cats without platelet clumping were mixed for 1 minute at the maximal setting using a standard vortex mixer. Blood smears (for subjective assessment of the type and amount of platelet clumping), platelet counts, and total leukocyte counts were evaluated before and after mixing. Vortex treatment of blood samples with platelet clumps caused an increased platelet count in all but 1 sample. Although most samples had strong increases in platelet counts after mixing, only a minority of samples (5 of 42) appeared to have all platelet clumps dispersed. Of 39 feline blood samples with platelet counts initially <200×109 cells/L, 23 counts increased to >200×109 cells/L and 34 counts increased to >100×109 cells/L. Overall, mixing gave inconsistent and partial improvement in platelet counts. Total leukocyte counts were not significantly affected by vortex mixing. Vortex mixing of 10 feline blood samples without platelet clumping had no consistent effect on platelet or WBC counts. In conclusion, vortex mixing of feline blood does not appear to be a consistent means of correcting the problem of feline platelet clumping.  相似文献   

15.
OBJECTIVE: To determine the prevalence of asymptomatic idiopathic macrothrombocytopenia in the population of Cavalier King Charles Spaniels (CKCS) in New South Wales (NSW) and to determine if it exhibits an autosomal recessive inheritance pattern. We also aimed to determine if significant differences existed when counting platelets manually, by auto analyser or by blood smear estimation in CKCS and mixed breed dogs. METHODS: Blood was collected from 172 dogs (152 CKCS and 20 mixed breed) and placed into sodium-citrate anticoagulant. Platelet counts were performed manually, by auto analyser and by blood smear estimates in CKCS and mixed breed dogs. Blood smears were also examined for platelet clumping and erythrocyte, leukocyte and platelet morphology. Pedigree analysis was performed to determine if an autosomal recessive inheritance pattern was supported. RESULTS: A statistically significant difference was found in platelet counts between CKCS and mixed breed dogs (P < 0.0001). CKCS had a platelet count that was 32% that of the controls (95% confidence interval, 28 to 37%). There was no significant difference between methods used to count platelets. Thirty percent of CKCS had macrothrombocytes. Pedigree analysis and examination of obtained and expected segregation ratios from 17 CKCS families supported an autosomal recessive pattern of Mendelian inheritance. CONCLUSIONS: A high prevalence of idiopathic macrothrombocytopenia exists in CKCS in NSW and automated or blood smear estimates are sufficient to count platelet numbers. Data supports an autosomal recessive inheritance pattern.  相似文献   

16.
A 2‐year‐old neutered male domestic shorthair cat was presented to the emergency service of the National Veterinary School of Toulouse (France) for acute vomiting and diarrhea with lethargy, inappetence, and adypsia for the past 48 hours. Complete blood counts were performed with the ProCyte DX at the emergency department and with the Sysmex XT‐2000iV at the laboratory 2 weeks later. The scattergrams from the two analyzers revealed similar unusual and abnormal dot plots. The Sysmex XT‐2000iV DIFF scattergram also showed no clear separation between different leukocyte populations. The eosinophil cluster was in an abnormal location compared with that of the “typical” location in a normal cat. A blood smear evaluation revealed the presence of numerous mast cells. Thus, we hypothesized that the Sysmex XT‐2000iV had detected the mast cell population, and this led to errors in the differential counts. To explore this hypothesis, we manually gated on the DIFF scattergram and performed a manual differential on the blood smear. With this new gating strategy, the Sysmex XT‐2000iV and manual differentials were similar. Thus, in the case of systemic mastocytosis, mast cells can be located between the lymphocyte, monocyte, and eosinophil clusters on scattergrams.  相似文献   

17.
Amphibian declines and extinctions have worsened in the last 2 decades. Partly because one of the main causes of the declines is infectious disease, veterinary professionals have increasingly become involved in amphibian research, captive husbandry, and management. Health evaluation of amphibians, free‐living or captive, can benefit from employing the tools of clinical pathology, something that is commonly used in veterinary medicine of other vertebrates. The present review compiles what is known of amphibian clinical pathology emphasizing knowledge that may assist with the interpretation of laboratory results, provides diagnostic recommendations for common amphibian diseases, and includes RIs for a few amphibian species estimated based on peer‐reviewed studies. We hope to encourage the incorporation of clinical pathology in amphibian practice and research, and to highlight the importance of applying veterinary medicine principles in furthering our knowledge of amphibian pathophysiology.  相似文献   

18.
BACKGROUND: The CA530-VET is a completely automated impedance cell hematology analyzer, which yields a 16-parameter blood count including a 3-part leukocyte differential. OBJECTIVES: The aim of this study was to examine the operational potential of the CA530-VET and its value for use in veterinary practice. METHODS: The analyzer was tested for blood carry-over, precision, and accuracy. Comparison methods included the CELL-DYN 3500, microhematocrit centrifugation, manual platelet (PLT) counting for feline and equine species, and a 100-cell manual WBC differential. Blood samples for comparison of the methods were obtained from 242 dogs, 166 cats, and 144 horses. RESULTS: The carry-over ratio (K) was 0.28% for RBC, 0.59% for PLT, 0.32% for WBC, and 0.18% for hemoglobin (HGB) concentration. Coefficients of variation (CVs) for within-batch precision and duplicate measurement of blood samples were clearly within the required limits, except for duplicate platelet counts in cats (8.7%) and horses (9.5%). The WBC count was in excellent agreement for dogs and horses and RBC count was in excellent agreement for horses. The accuracy of feline WBC counts was not acceptable, with the exception of values at the high end of the range. RBC counts in dogs and cats, and HGB concentration and MCV in all 3 species were sufficiently accurate. The CA530-VET HCT results were in excellent agreement with microhematocrit results in horses but exceeded the maximum allowed inaccuracy for cats and dogs. In all species, PLT counts established mechanically and manually were not in adequate agreement. Large differences were found between the CA530-VET and the manual differential percentage for lymphocytes and "mid-sized cells" (monocytes and basophilic granulocytes). CONCLUSIONS: The CA530-VET can be considered useful for routine canine, feline, and equine blood cell analyses. It should not be considered accurate, however, for PLT counts, feline total WBC counts in the subnormal and normal range, and leukocyte differentials, except for granulocytes.  相似文献   

19.
The clinical hematology practices utilized at veterinary teaching hospitals and private veterinary diagnostic laboratories were surveyed using a questionnaire. The hematology caseload at private diagnostic laboratories was larger, and comprised predominantly of canine and feline submissions. The Coulter S Plus IV and Serono Baker 9000 were the hematology analyzers used most frequently at veterinary medical laboratories. The Abbott Cell-Dyn 3500, a multispecies analyzer capable of leukocyte differential counting, was utilized more by private laboratories. Commercial hematology control reagents were used at all laboratories; teaching hospital laboratories more often used reagents supplied by the manufacturer of the analyzer. A greater percentage of private diagnostic laboratories participated in the external quality assurance programs offered by Veterinary Laboratory Association and College of American Pathologists. While private diagnostic laboratories retained the EDTA blood specimens longer after initial testing, the teaching hospital laboratories retained blood smears and complete blood count reports longer. The complete blood count reports at veterinary teaching laboratories more often included red blood cell volume distribution width, mean platelet volume, manual hematocrit, plasma protein, and leukocyte differentials as absolute concentrations. The laboratory practices utilized by these veterinary medical laboratories were generally similar, and differences were attributed to divergent emphasis on economic accountability and clinical investigation.  相似文献   

20.
Platelet counts were performed in 43 Cavalier King Charles Spaniels (CKCS, a breed predisposed to macrothrombocytopenia) and in 10 control dogs using 3 automated systems and 3 manual methods (erythrocyte-lysing agents + counting chamber or evaluation of blood smear). Good correlations were found between platelet counts using all methods (all P < 0.0001; R2 = 0.71-0.85). Best correlations were found between the manual methods. Significantly larger platelets were found in CKCS with platelet count < or = 100,000/microl when compared with control dogs and CKCS with platelet count > 100,000/microl (both P < 0.0001). All platelet counts--except when made with the 2 counting chamber methods--were underestimated at platelet counts < or = 100,000/microl.  相似文献   