首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
OBJECTIVE: To investigate the potential use of fluorescent-labeled annexin V, anti-human fibrinogen antibody, and anti-human thrombospondin antibody for detection of the activation of equine platelets by use of flow cytometry. SAMPLE POPULATION: Platelets obtained from 6 Thoroughbreds. PROCEDURE: Flow cytometry was used to assess platelet activation as indicated by detection of binding of fluorescent-labeled annexin V, anti-human fibrinogen antibody, and anti-thrombospondin antibody to unactivated and ADP-, collagen-, platelet activating factor (PAF)-, and A23187-activated equine platelets. Human platelets were used as control samples. Determination of 14C-serotonin uptake and release was used to assess the extent of platelet secretion. RESULTS: Anti-human thrombospondin antibody failed to bind to equine platelets. Annexin V bound to platelets activated with PAF or A23187 when platelets had undergone secretion. Anti-human fibrinogen antibody bound to ADP-, PAF-, and A23817-activated platelets, but binding was not dependent on platelet secretion. The extent of binding of anti-fibrinogen antibody was less in equine platelets, compared with that for human platelets, despite maximal stimulation. CONCLUSIONS AND CLINICAL RELEVANCE: Activation of equine platelets can be detected by use of fluorescent-labeled annexin V and anti-human fibrinogen antibody but not by use of anti-human thrombospondin antibody. These flow cytometric techniques have the potential for detection of in vivo platelet activation in horses at risk of developing thrombotic disorders.  相似文献   

2.
OBJECTIVE: To investigate the effects of sodium citrate, low molecular weight heparin (LMWH), and prostaglandin E1 (PGE1) on aggregation, fibrinogen binding, and enumeration of equine platelets. SAMPLE POPULATION: Blood samples obtained from 4 Thoroughbreds. PROCEDURE: Blood was collected into syringes in the ratio of 9 parts blood:1 part anticoagulant. Anticoagulants used were sodium citrate, LMWH, sodium citrate and LMWH, or 300 nM PGE1/ml of anticoagulant. Platelet aggregation in response to ADP, collagen, and PGE1 was assessed, using optical aggregometry. Platelet activation was evaluated, using flow cytometry, to detect binding of fluorescein-conjugated anti-human fibrinogen antibody. Plasma concentration of ionized calcium was measured, using an ion-selective electrode. RESULTS: Number of platelets (mean +/- SEM) in samples containing LMWH (109.5+/-11.3 x 10(3) cells/microl) was significantly less than the number in samples containing sodium citrate (187.3+/-30.3 x 10(3) cells/microl). Increasing concentrations of sodium citrate resulted in reductions in platelet aggregation and plasma concentration of ionized calcium. Addition of PGE1 prior to addition of an agonist inhibited platelet aggregation in a concentration-dependent manner, whereas addition of PGE1 4 minutes after addition of ADP resulted in partial reversal of aggregation and fibrinogen binding. CONCLUSIONS AND CLINICAL RELEVANCE: A high concentration of sodium citrate in blood samples decreases plasma concentration of ionized calcium, resulting in reduced platelet aggregation and fibrinogen binding. Platelets tend to clump in samples collected into LMWH, precluding its use as an anticoagulant. Platelet aggregation and fibrinogen binding can be reversed by PGE1, which may result in underestimation of platelet activation.  相似文献   

3.
Background: Platelet activation appears to play a role in a variety of canine thrombotic disorders. At present, tests for the detection of activated platelets are not used routinely in veterinary clinical laboratories. Objective: The purpose of this study was to develop a clinically applicable method to detect activated canine platelets. Methods: A flow cytometric assay was developed to detect activated platelets, platelet aggregates, and platelet microparticles in the dog. Blood was collected from healthy dogs using EDTA or sodium citrate as the anticoagulant, and platelet‐rich plasma was prepared. Platelets were activated by adding phorbol myristate acetate. In some experiments, platelets were fixed by incubation with 0.5% paraformaldehyde. In other experiments, platelets were stored for 4 or 24 hours at 4°C before analysis. Activated platelets were detected by measuring surface expression of P‐selectin and by determining the percentages of platelet aggregates and microparticles using forward‐angle vs side‐angle light scatter plots. Results were analyzed by using 2‐way ANOVA and the SchefféF‐test. Results: Platelets collected in EDTA had minimal expression of P‐selectin, whereas platelets collected in sodium citrate had greater median fluorescence intensity. Fixation with 0.5% paraformaldehyde before labeling platelets with anti‐P‐selectin did not affect antibody binding or the percentages of platelet aggregates and microparticles. Storage of platelet‐rich plasma at 4°C for 4 hours did not affect antibody binding or the percentages of platelet aggregates or microparticles. Activation of platelets ex vivo by addition of 10 ng/mL phorbol myristate acetate resulted in a large increase in expression of P‐selectin but only slight increases in platelet aggregates and microparticles. Conclusion: Determination of platelet P‐selectin expression and percentages of platelet aggregates and platelet microparticles may provide a clinically applicable means for detection of activated platelets in dogs. The capacity to use EDTA‐anticoagulated blood samples and to fix platelets for evaluation at a later time makes the test attractive as a routine diagnostic tool.  相似文献   

4.
Immunofluorescence, tube agglutination, and platelet factor-3 immunoinjury tests for detecting antiplatelet antibody were compared using a heterologous system of equine platelets and rabbit antiequine platelet serum. Platelet immunofluorescence tests were performed using paratormaldehyde-fixed platelets in suspension as well as in air-dried smears on glass slides (solid phase). Bright homogeneous, membranous, specific fluorescence was seen in both assays with anti-immunoglobulin G (IgG) and protein G fluorescein isothiocynate conjugates (FITC-conjugates). Protein A conjugate gave nonspecific fluorescence irrespective of normal or antiserum treatment. Anti-IgG and protein G conjugates in suspension immunofluorescence tests with the same antiserum yielded antibody titers of 1:1024 and 1:128, respectively. Similarly, respective titers of 1:512 and 1:64 were obtained with solid phase immunoassay. Platelet suspension assay was slightly better than the solid phase assay. These observations indicated that anti-IgG was more sensitive than protein G in detecting antiplatelet antibody by fluorescence microscopy, while protein A was ineffective because of its nonspecificity. Chloroquine treatment of platelets failed to reduce the nonspecific fluorescence. Platelet agglutination and platelet factor-3 tests were relatively less sensitive to detect equine antiplatelet antibody.  相似文献   

5.
Recurrent airway obstruction (RAO) in mature horses is characterized by reversible airway obstruction and neutrophilic inflammation; there is also functional activation of circulating platelets and neutrophils. This study was undertaken to determine if changes in activation marker expression and heterotypic aggregate formation can be used as an indicator of this increased functional responsiveness.In vitro conditions for flow cytometric measurement of CD13, CD41/61 and CD62P expression on activated cells and heterotypic aggregate formation were established. Values were then compared before and after antigen challenge of RAO and healthy horses. Platelet adhesion to serum-coated plastic was measured as a functional marker of platelet activation.In vitro activation resulted in increased expression of neutrophil CD13 and platelet CD41/61 and CD62P. Activation of both cell types caused a significant increase in neutrophil–platelet aggregates.In horses with RAO, but not controls, there was a significant increase in the percentage of CD13 positive neutrophils at 10 h and 24 h and in the mean fluorescence intensity at 10 h. This was accompanied at 24 h by an increased mean platelet side scatter and thrombin-stimulated platelet adhesion.In conclusion, CD13 expression can be used as an indicator of equine neutrophil activation both in vitro and in vivo. Equine platelet activation in vitro can be detected by measuring CD41/61 or CD62P expression, and PAF-activated platelets and neutrophils form aggregates. However, despite evidence of circulating platelet activation, neither a change in expression of platelet activation markers, nor heterotypic aggregate aggregate formation could be detected.  相似文献   

6.
OBJECTIVE: To evaluate Coomassie blue staining of the acrosome of equine and canine spermatozoa. SAMPLE POPULATION: Spermatozoa of 5 mixed-breed male dogs and 3 Thoroughbred stallions. PROCEDURE: Various proportions of intact and acrosome-damaged spermatozoa were fixed in 2% phosphate-buffered formaldehyde or 4% paraformaldehyde, smeared onto glass slides, and stained with Coomassie blue stain. Acrosomal status (damaged vs intact) was also assessed by use of flow cytometry after staining with fluorescein isothiocyanate-conjugated Pisum sativum agglutinin (FITC-PSA) and propidium iodide. Comparisons were made between percentages of expected and observed acrosome-intact spermatozoa in different proportions of live and flash-frozen samples; the percentages of acrosome-intact spermatozoa as determined by use of Coomassie blue staining and flow cytometry were also compared. RESULTS: Strong correlations were found between the expected and observed distributions of acrosome-intact spermatozoa when fixed in 4% paraformaldehyde (r2 = 0.93 and 0.89 for canine and equine spermatozoa, respectively) as well as between Coomassie blue-stained cells and those stained with FITC-PSA and assessed by use of flow cytometry (r2 = 0.96 and 0.97 for canine and equine spermatozoa, respectively). However, in canine samples that were fixed in 2% phosphate-buffered formaldehyde, these correlations were weak. CONCLUSIONS AND CLINICAL RELEVANCE: Staining with Coomassie blue stain was a simple and accurate method to evaluate the acrosome in equine and canine spermatozoa after fixation in 4% paraformaldehyde. This assay should be useful in routine evaluation of semen samples from these species.  相似文献   

7.
BACKGROUND: Blood collection tubes containing 3.2% (0.109 M) sodium citrate, instead of 3.8% (0.129 M) sodium citrate, have recently become available in the United States. These tubes are visually indistinguishable from the traditional 3.8% sodium citrate tubes, except for wording on the label. Consequently, samples for hemostatic evaluation are frequently collected in tubes containing the lower concentration of sodium citrate. HYPOTHESIS: Results of hemostasis assays are different in samples collected in 3.2% versus 3.8% sodium citrate. ANIMALS: Twenty healthy dogs. METHODS: This study aimed at determining whether results of standard coagulation tests, von Willebrand factor concentration (vWF:Ag), and platelet function with the platelet function analyzer PFA-100a were affected by the different concentrations of sodium citrate. Blood samples were collected in tubes containing either 3.2% or 3.8% sodium citrate concentrations and processed routinely for coagulation assays (one-stage prothrombin time [OSPT], activated partial thromboplastin time [aPTT], fibrinogen concentration, and platelet count), vWF:Ag, and platelet function assays with a PFA-100. RESULTS: There was no significant difference between samples collected in 3.2% versus those collected in 3.8% sodium citrate for OSPT, aPTT, fibrinogen concentration, platelet count, or vWF:Ag. The closure times with collagen/adenosine diphosphate were significantly shorter (66 +/- 8.1 versus 74.8 +/- 9.7 seconds; P < .0001) with the 3.2% than with 3.8% sodium citrate concentration, and the hematocrit was significantly higher (47.9 +/- 5.6 versus 46.0 +/- 4.7 seconds; P = .03) in samples collected in 3.2% than in those collected in 3.8% sodium citrate. CONCLUSIONS AND CLINICAL IMPORTANCE: There is no clinically relevant effect of collection of blood into 3.2% or 3.8% sodium citrate.  相似文献   

8.
Background: Thromboelastometry is used for identifying or monitoring coagulation abnormalities. It has been validated in several species but not in horses and the characteristics of the equine thromboelastogram have not yet been detailed. Objectives: The purpose of this study was to validate a thromboelastometer to be used with equine blood and to define the normal equine thromboelastogram. Methods: A Rotem-gamma thromboelastometer (Pentapharm GmbH, Munich, Germany) was used on 38 citrated blood samples to investigate native coagulation, the intrinsic and extrinsic pathways, the function of fibrinogen (largely dependent on its concentration), and the presence of fibrinolysis. Using classic validation approaches, we evaluated the imprecision of the method and the influence of hemolysis and storage time and temperature. The normal thromboelastogram was defined in both saddle and racing horses (the latter sampled before and after the race). Results: For imprecision tests, the analytical variations were <10%. The equine thromboelastogram had a pattern similar to those of other species, but the intrinsic and extrinsic pathways were less and more efficient, respectively. Reference intervals in racing horses, especially after exercise, were different from those of saddle horses, most likely due to a higher RBC mass. Coagulability decreased in hemolyzed samples and significant changes were found between nonrefrigerated and refrigerated blood samples stored for 20 hours. Conclusions: The Rotem-gamma thromboelastometer is a precise instrument for use with equine blood samples. The equine thromboelastogram is similar to that of other species, but reference intervals vary with aptitude and exercise. Hemolysis and refrigeration alter thromboelastometric results.  相似文献   

9.
The propensities of several fluids for extracting formaldehyde from fixed muscle tissue were compared. Following formalin fixation, similar samples of muscle tissue were immersed in solutions of 0.5%, 1%, 2%, 4% phenoxyethanol, 40% ethanol, 25% ethylene glycol or water. Following storage periods of 4, 25, 50 or 100 days, the formaldehyde content of the fluids was determined by sodium sulfite titration. The solution containing 40% ethanol was clearly superior to the others. Solutions containing 2% or 4% phenoxyethanol were least effective and there was a significant inverse linear relationship between the concentration of phenoxyethanol and amount of formaldehyde extracted. This suggests that phenoxyethanol decreases the ability of water to extract formaldehyde from fixed tissues.  相似文献   

10.
Expression of four leukocyte adhesion factors on canine leukocytes was studied by flow cytometry using a no-lyse, no-wash method. The effect of fixation and storage for up to 14 days in 1% paraformaldehyde on labelled samples and within assay variation was evaluated. Monoclonal antibodies directed to monocyte marker CD14, and to adhesion molecules CD11a, CD18, CD32 and CD49d were used. Cell surface marker, cell population, time, and the interactions between time and cell marker significantly affected expression of cell adhesion factors. For CD18, there was a significant difference in mean fluorescence intensity (MFI) between fresh and stored samples (P<0.001), but no significant difference between stored samples. The MFIs of CD11a and CD49d were not significantly affected by fixation and storage. The CVs differed significantly depending on cell marker (P<0.001) and cell population (P=0.005). Fixation and storage did not significantly affect the CV. In conclusion, a no-lyse, no-wash method can be applied to canine leukocytes. The effect of fixation and storage on the resulting MFI differs between monoclonal antibodies, and should be evaluated for each antibody before use. The coefficient of variation was generally acceptable, and high CVs were related to a low MFIs or low numbers of analysed cells.  相似文献   

11.
Twenty-two ponies were examined for serum-neutralizing (SN) antibody to equine herpesvirus type 1 and for in vitro lymphocyte transformation in the presence of viral antigen. Six ponies had undetectable levels of neutralizing antibody (titer less than 1:2) and had lymphocytes which did not respond in culture with viral antigen (stimulation index less than 2.0). Four ponies which had SN antibody to equine herpesvirus type 1 did not manifest lymphocyte transformation in vitro. The 12 remaining seropositive ponies had lymphocyte transformation with viral antigen in vitro (stimulation indexes from 2.0 to 23.5). Lymphocyte transformation was specifically suppressed when cells were grown in medium containing autologous serum. The temporal development of in vitro lymphocyte responsiveness and SN antibody in 3 specific-pathogenfree ponies after experimentally induced infection with equine herpesvirus type 1 is described.  相似文献   

12.
Most embalming of cadavers for anatomical dissection in veterinary medicine has used 6-10% formaldehyde resulting in discoloured and rigid specimens. This project produced teaching specimens of sheep, horse and calf cadavers having their musculoskeletal and visceral structures with a natural appearance using a fixation solution with lowered concentrations of formaldehyde (2% and 3%) together with ethanol and polyethylene glycols. Fixation parameters (palpable consistency, flexibility, colour, tissue hydration and odour) were assessed qualitatively by twice weekly dissections over two months for sheep and three months for horses and calf. Formaldehyde levels, measured in the breathing zone, were below the maximum allowable concentration in all specimens except for a 300 kg horse cadaver. To evaluate the effectiveness of the fixation solution in microbial inhibition, tissue samples were taken and analyzed for the presence of culturable aerobic and anaerobic bacteria, yeasts and moulds. Single colonies of Pseudomonas oryzihabitans, Chryseobacterium sp., Acinetobacter sp. were isolated from lungs, and Micrococcus sp. and Bacillus sp. were isolated from one muscle sample.  相似文献   

13.
Background: Critically ill horses are susceptible to thrombotic disease, which might be related to increased platelet reactivity and activation. Objectives: To compare the effect of oral clopidogrel and aspirin (ASA) on equine platelet function. Animals: Six healthy adult horses. Methods: Horses received clopidogrel (2 mg/kg PO q24h) or ASA (5 mg/kg PO q24h) for 5 days in a prospective randomized cross‐over design. Platelet aggregation responses to adenosine diphosphate (ADP) and collagen via optical aggregometry, and platelet secretion of serotonin (5HT) and production of thromboxane B2 (TXB2) by ELISA were evaluated. In horses receiving clopidogrel, high‐performance liquid chromatography analysis for clopidogrel and its carboxylic‐acid metabolite SR 26334 was performed. Results: SR 26334 was identified in all clopidogrel‐treated horses, although the parent compound was not detected. Clopidogrel resulted in decreases in ADP‐induced platelet aggregation persisting for 120 hours after the final dose. ADP‐induced platelet aggregation decreased from a baseline of 70.2 ± 14.7% to a minimum of 15.9 ± 7.7% 24 hours after the final dose (P < .001). Collagen‐induced aggregation decreased from a baseline of 93 ± 9.5% to a minimum of 70.8 ± 16.9% 48 hours after the final dose (P < .001). ASA did not decrease platelet aggregation with either agonist. ASA decreased serum TXB2 from a baseline value of 1310 ± 1045 to 128 ± 64 pg/mL within 24 hours (P < .01). Conclusions and Clinical Importance: Clopidogrel effectively decreases ADP‐induced platelet aggregation in horses, and could have therapeutic applications for equine diseases associated with platelet activation.  相似文献   

14.
An automated, multi-channel blood cell counting system (S-Plus) was compared to a reference counting system using blood samples from 187 animals of four species. The standard red cell bath aperture current of 150 volts (V) was used during analysis of 75% of the samples. At this setting, all samples with a Mean Corpuscular Volume (MCV) greater than 50 fl had accurate erythrocyte counts. As the MCV decreased below 50 fl, the severity of false low erythrocyte counts and false high MCV values increased. The remaining 25% of samples were analyzed with the red cell bath aperture current increased to 200 V. At this setting, only 5% or less of erythrocytes from animals with normal MCV values(>36 fl)were below the erythrocyte threshold. The red cell distribution width values provided by the S-Plus indicated that equine and bovine erythrocytes have greater anisocytosis than canine and feline erythrocytes. Leukocyte counts were significantly lower on the S-Plus (p<0.01). Canine and equine samples most frequently had platelet size distribution within the S-Plus platelet counting threshold window. Electronic whole blood platelet counting appeared unsatisfactory in cats due to large platelet size and erythrocyte-platelet size overlap. Small platelet size in cattle indicated that further modifications of the red cell bath aperture current would be required to count and size platelets in this species. Following electronic modifications, this state-of-the-art system appears adaptable to hematologic profiling in most species.  相似文献   

15.
Equine neutrophil antibody was raised in rabbits inoculated with equine neutrophils isolated to purity greater than 99.0%, using Percoll density-gradient sedimentation. Neutrophil antibody was detected by use of agar gel diffusion, leukoagglutination, indirect immunofluorescence, staphylococcal protein A and streptococcal protein G binding, and phagocytic inhibition techniques. Precipitin lines and leukoagglutination were seen in antiserum dilutions of 1:4 and 1:64, respectively. The specific nature of leukoagglutination was characterized by the formation of rosette-like clumps of neutrophils. Specific bright membranous fluorescence was seen in neutrophils treated with the antiserum and exposed to fluorescein-conjugated goat anti-rabbit immunoglobulin, and staphylococcal protein A and streptococcal protein G. Whereas the indirect immunofluorescence and protein G-binding tests were equally sensitive and resulted in titer of 1:256, the protein A-binding test was less sensitive and resulted in titer of only 1:32. Nonspecific binding of protein A and protein G was noticed as uniform or patchy cellular fluorescence in a small number of neutrophils. Treatment of neutrophils with antiserum up to dilution of 1:8 resulted in a significant (P less than 0.05) suppression of phagocytosis of opsonized zymosan particles. Thus, protein G-binding and indirect immunofluorescence tests are highly sensitive to detect neutrophil antibody and may be used to diagnose immune-mediated neutropenias in horses and, possibly, in other animal species.  相似文献   

16.
AIM: To identify viruses associated with respiratory disease in young horses in New Zealand.

METHODS: Nasal swabs and blood samples were collected from 45 foals or horses from five separate outbreaks of respiratory disease that occurred in New Zealand in 1996, and from 37 yearlings at the time of the annual yearling sales in January that same year. Virus isolation from nasal swabs and peripheral blood leukocytes (PBL) was undertaken and serum samples were tested for antibodies against equine herpesviruses (EHV-1, EHV-2, EHV-4 and EHV-5), equine rhinitis-A virus (ERAV), equine rhinitis-B virus (ERBV), equine adenovirus 1 (EAdV-1), equine arteritis virus (EAV), reovirus 3 and parainfluenza virus type 3 (PIV3).

RESULTS: Viruses were isolated from 24/94 (26%) nasal swab samples and from 77/80 (96%) PBL samples collected from both healthy horses and horses showing clinical signs of respiratory disease. All isolates were identified as EHV-2, EHV-4, EHV-5 or untyped EHV. Of the horses and foals tested, 59/82 (72%) were positive for EHV-1 and/or EHV-4 serum neutralising (SN) antibody on at least one sampling occasion, 52/82 (63%) for EHV-1-specific antibody tested by enzyme-linked immunosorbent assay (ELISA), 10/80 (13%) for ERAV SN antibody, 60/80 (75%) for ERBV SN antibody, and 42/80 (53%) for haemagglutination inhibition (HI) antibody to EAdV-1. None of the 64 serum samples tested were positive for antibodies to EAV, reovirus 3 or PIV3. Evidence of infection with all viruses tested was detected in both healthy horses and in horses showing clinical signs of respiratory disease. Recent EHV-2 infection was associated with the development of signs of respiratory disease among yearlings [relative risk (RR)=2.67, 95% CI=1.59-4.47, p=0.017].

CONCLUSIONS: Of the equine respiratory viruses detected in horses in New Zealand during this study, EHV-2 was most likely to be associated with respiratory disease. However, factors other than viral infection are probably important in the development of clinical signs of disease.  相似文献   

17.
Reasons for performing study: Accurate measurement of plasma fibrinogen concentrations is an important tool for assessment of horses with inflammatory diseases. Objectives: To determine the precision and accuracy of a benchtop instrument using both fresh and frozen equine plasma by comparing the plasma fibrinogen concentration measured by a benchtop instrument to 2 separate laboratory standard methods (ACL 100 and STA Compact) for fibrinogen measurement. Methods: Accuracy and precision of the VSPro was evaluated using both human fibrinogen standards and samples from horses. Fifty frozen samples from horses with gastrointestinal disease had the fibrinogen concentration measured using the ACL 1000 and the VSPro. Fifty fresh samples were collected from hospitalised horses and fibrinogen concentration was measured using the STA Compact coagulation machine and the VSPro. Correlations for measurements were performed, as well as Bland‐Altman analysis. Results: Coefficients of variability for the VSPro ranged from 7% to 15%. The VSPro fibrinogen values were well correlated to both the ACL 1000 (r = 0.94, P<0.001) and the STA Compact measurements (r = 0.926, P<0.001). Bland‐Altman analysis showed a mean bias of ‐0.83 g/l (95% confidence interval ‐2.03–0.324 g/l) for the ACL 1000 and a mean bias of ‐0.024 g/l (95% confidence interval ‐1.434–1.386 g/l) for the STA Compact. Conclusions: The VSPro appears to have adequate accuracy and precision for clinical measurement of plasma fibrinogen concentrations. Potential relevance: The VSPro provides a measurement of equine plasma fibrinogen concentration using a benchtop instrument with a rapid test time that has comparable accuracy to the fibrinogen concentration obtained from reference laboratories.  相似文献   

18.
BACKGROUND: The ADVIA 120 is an automated laser cell counter widely used in veterinary medicine. Although specific software for equine samples is available and validated, only a few reports have been published comparing the ADVIA 120 with other methods for equine hemogram evaluation. OBJECTIVES: The purpose of this study was to compare the hematologic values and reference intervals obtained on the ADVIA 120 with those obtained on an impedance cell counter and manual differential counts in healthy horses. METHODS: EDTA-anticoagulated blood samples were obtained from 114 clinically healthy horses of various breeds, both sexes, and 2-6 years of age. Samples were stored for up to 12 hours at 4 degrees C and then analyzed on the ADVIA 120 and the Hemat 8. A 100-cell to 200-cell differential leukocyte count was performed by 3 independent observers on May-Grünwald-Giemsa-stained smears. Intra-assay precision of the ADVIA 120 was determined by analyzing 5 replicates each of 10 of the blood samples. RESULTS: Results from the ADVIA were significantly higher than those from the impedance counter for RBC count, total WBC count, hemoglobin concentration, red cell distribution width, MCH, and MCHC, and significantly lower for HCT and platelet count. Significantly higher neutrophil and basophil counts and significantly lower lymphocyte counts were obtained with the ADVIA 120 compared with manual counts. Based on Passing-Bablok regression analysis, RBC and platelet counts were in good agreement between the 2 analyzers; a constant and proportional bias was present for other values. Coefficients of variation for erythrocyte parameters on the ADVIA were <1%, but were higher for platelet (6%), total WBC (2%), differential WBC (4%-30%), and reticulocyte (75%) counts. CONCLUSIONS: Results obtained with equine samples on the ADVIA 120 were comparable with those obtained on an impedance counter; reference intervals differed statistically but overlapped. The ADVIA had poor precision for reticulocyte and differential leukocyte counts such that the latter should always be verified on smears.  相似文献   

19.
Abstract: Flow cytometric detection of platelet surface-associated IgG (PSAIgG) can be used to determine whether immunologic factors are contributing to thrombocytopenia in dogs. In vitro alterations in platelet activation and morphology, however, could impact the results of this test. The purpose of this study was to determine whether the PSAIgG test for immune-mediated thrombocytopenia was valid on whole blood in EDTA anticoagulant after 24–72 hours of storage, and to characterize other alterations in canine platelets that could impact immunologic testing. Platelets were harvested and analyzed immediately after blood collection and after 24, 48, and 72 hours of storage at 4°C. Spontaneous and thrombin-induced changes in the following platelet parameters were evaluated using flow cytometric techniques: PSAIgG, platelet microparticle formation, membrane expression of P-selectin and glycoprotein CD61, exogenous IgG binding, surface-exposed phosphatidylserine, and fibrinogen binding. The amount of PSAIgG increased 6-to 9-fold in stored samples compared with fresh samples. Platelet microparticle formation was spontaneous in stored samples and increased significantly over time. Membrane phosphatidylserine, P-selectin, and fibrinogen binding were not altered by storage, indicating that platelet activation was minimal in stored samples. Although storage decreased the percentage of platelets positive for CD61 by 8-to 10-fold compared with fresh samples, activation by high-dose thrombin partially restored the percentage of CD61-positive platelets in 24-hour-old samples. In conclusion, even though platelets stored in EDTA for up to 72 hours remain in a resting state, aged platelets have an increased tendency to form microparticles and have increased surface IgG and decreased surface CD61, which may contribute to false-positive results for tests of immune-mediated thrombocytopenia.  相似文献   

20.
Effect of equine ehrlichial colitis on the hemostatic system in ponies   总被引:1,自引:0,他引:1  
Hemostatic function was determined in 10 ponies at various times after inoculation with Ehrlichia risticii to determine whether equine ehrlichial colitis (EEC) caused changes in the hemostatic system and to determine the prognostic value of hemostatic function tests during EEC. Mean platelet count; plasma fibrinogen, fibronectin, factor VIII: coagulant, alpha 2-antiplasmin, and plasminogen values; and serum concentrations of fibrin/fibrinogen degradation products changed significantly (P less than 0.05) from base line (day 0, before inoculation) during 18 days after inoculation with E risticii. Four ponies that died or were euthanatized because of severe clinical signs of EEC had significantly (P less than 0.05) greater mean plasma fibrinogen concentrations plasma factor VIII:coagulant values, and activated partial thromboplastin times immediately before death than did the 6 surviving ponies. Factor V concentrations were significantly (P less than 0.05) lower on postinoculation days 10 and 20 in nonsurvivors. Seemingly, changes in hemostasis took place during EEC. Ponies that did not survive EEC had greater laboratory evidence of coagulopathy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号